Electronic Oven Control (EOC) Fault Code Descriptions
Code Condition / Cause Suggested Corrective Action
F10
F11
F12
F13
Runaway Temperature.
Shorted Keypad.
Bad Micro Identication.
Bad EEPROM Identication/Checksum error.
1. 1. (F10 only) Check RTD Sensor Probe & harness. Replace if necessary. If oven
is overheating, disconnect power. If oven continues to overheat when the power is
reapplied, replace EOC. Severe overheating may require the entire oven to be replaced
should damage be extensive.
2. (F11, 12 & 13) Disconnect power, wait 30 seconds and reapply power.
3. (F11, 12 & 13) If fault returns upon power-up, replace EOC.
F30
F31
Open probe circuit.
Shorted Probe circuit
1. (F30 or F31) Check resistance at room temperature & compare to RTD Sensor resis-
tance chart. If resistance does not match the RTD chart replace RTD Sensor Probe.
Check Sensor wiring harness between EOC & Sensor Probe connector.
2. (F30 or F31) Check resistance at room temperature, if less than 500 ohms, replace
RTD Sensor Probe. Check for open or shorted Sensor Probe harness between EOC &
Probe connector.
F90
F91
F92
F93
F94
Maximum oven door unlock time exceeded.
Maximum oven door unlock attempts exceeded.
Maximum oven door open time exceeded.
Maximum oven door lock time exceeded.
Maximum oven door lock attempts exceeded.
IF LATCH MOTOR RUNS:
1. (F90, 91, 92, 93 & 94) Check the wiring between EOC & Lock Motor Micro Switch.
2. (F90, 91, 92, 93 & 94) Check the contacts of Micro-Switch on latch motor assembly. If
contacts are open when motor cam depresses switch, replace Lock Motor Assembly.
3. (F90, 91, 92, 93 & 94) Check for binding of the Latch Cam, Lock Motor Rod & Lock
Motor Cam.
4. If all situations above do not solve probem, replace EOC.
IF LATCH MOTOR DOES NOT RUN
1. (F90, 91, 92, 93 & 94) Check to see if Lock Motor Coil is open. If open, replace Lock
Motor Assembly.
2. (F92, 93 & 94) Check oven door Light Switch - if open, replace Switch.
3. If all situations above do not solve probem, replace EOC.
NOTICE - This service data sheet is intended for use by persons
having electrical and mechanical training and a level of knowledge
of these subjects generally considered acceptable in the appliance
repair trade. The manufacturer cannot be responsible, nor
assume any liability for injury or damage of any kind arising from
the use of this data sheet.
Safe Servicing Practices
To avoid the possibility of personal injury and/or property damage, it is im-
portant that safe servicing practices be observed. The following are some,
but not all, examples of safe practices.
1. Before servicing or moving an appliance remove power cord from
electrical outlet, trip circuit breaker to OFF, or remove fuse.
2. Never interfere with the proper installation of any safety device.
3. GROUNDING: The standard color coding for safety ground wires
is GREEN or GREEN WITH YELLOW STRIPES. Ground leads
are not to be used as current carrying conductors. It is extremely
important that the service technician reestablish all safety
grounds prior to completion of service. Failure to do so will
create a potential safety hazard.
IMPORTANT
DO NOT REMOVE THIS BAG
OR DESTROY THE CONTENTS
WIRING DIAGRAMS AND SERVICE
INFORMATION ENCLOSED
REPLACE CONTENTS IN BAG
Resistance (ohms)
1000 ± 4.0
1091 ± 5.3
1453 ± 8.9
1654 ± 10.8
1852 ± 13.5
2047 ± 15.8
2237 ± 18.5
2697 ± 24.4
Open circuit/infinite resistance
RTD SCALE
Temperature °F (°C)
32 ± 1.9 (0 ± 1.0)
75 ± 2.5 (24 ± 1.3)
250 ± 4.4 (121 ± 2.4)
350 ± 5.4 (177 ± 3.0)
450 ± 6.9 (232 ± 3.8)
550 ± 8.2 (288 ± 4.5)
650 ± 9.6 (343 ± 5.3)
900 ± 13.6 (482 ±7.5)
Probe circuit to case ground
Resistance Temperature Detector
p/n 808533108 EN (1712)
SERVICE DATA SHEET
Gas ranges with ES 300/330 electronic oven control
4. Prior to returning the product to service, ensure that:
All electric connections are correct and secure.
All electrical leads are properly dressed and secured away from
sharp edges, high-temperature components, and moving parts.
All uninsulated electrical terminals, connectors, heaters, etc. are
adequately spaced away from all metal parts and panels.
All safety grounds (both internal and external) are correctly and
securely reassembled.
Oven Calibration
Set the electronic oven control for normal baking at 350°F. Obtain an average oven
temperature after a minimum of 5 cycles. Press Clear/Off/Cancel to end bake
mode.
Temperature Adjustment
1. Set EOC to bake at 550°F.
2. Within 5 seconds of setting 550°F, press and hold the bake pad for
approximately 15 seconds until a single beep is heard (longer may cause
F11 shorted keypad alarm).
3. Calibration offset should appear in the display.
4. Use the slew keys to adjust the oven temperature up or down 35°F in 5°F
increments.
5. Once the desired (-35° to 35°) offset has been applied, press Press Clear/
Off/ Cancel.
Note: Changing calibration affects normal Bake mode. The adjustments made will
not change the Self-Cleaning cycle temperature.
Electronic Oven Control (EOC) P5 connections
ELECTRONIC OVEN CONTROL (E.O.C. Rear View)
P5
** = some models.
**
CIRCUIT ANALYSIS MATRIX
(some
models)
MDL
(some models)
General Troubleshooting SchematicGeneral Troubleshooting Diagram
Electronic Oven Control (EOC) Fault Code Descriptions
Code Condition / Cause Suggested Corrective Action
F10
F11
F12
F13
Runaway Temperature.
Shorted Keypad.
Bad Micro Identication.
Bad EEPROM Identication/Checksum error.
1. 1. (F10 only) Check RTD Sensor Probe & harness. Replace if necessary. If oven
is overheating, disconnect power. If oven continues to overheat when the power is
reapplied, replace EOC. Severe overheating may require the entire oven to be replaced
should damage be extensive.
2. (F11, 12 & 13) Disconnect power, wait 30 seconds and reapply power.
3. (F11, 12 & 13) If fault returns upon power-up, replace EOC.
F30
F31
Open probe circuit.
Shorted Probe circuit
1. (F30 or F31) Check resistance at room temperature & compare to RTD Sensor resis-
tance chart. If resistance does not match the RTD chart replace RTD Sensor Probe.
Check Sensor wiring harness between EOC & Sensor Probe connector.
2. (F30 or F31) Check resistance at room temperature, if less than 500 ohms, replace
RTD Sensor Probe. Check for open or shorted Sensor Probe harness between EOC &
Probe connector.
F90
F91
F92
F93
F94
Maximum oven door unlock time exceeded.
Maximum oven door unlock attempts exceeded.
Maximum oven door open time exceeded.
Maximum oven door lock time exceeded.
Maximum oven door lock attempts exceeded.
IF LATCH MOTOR RUNS:
1. (F90, 91, 92, 93 & 94) Check the wiring between EOC & Lock Motor Micro Switch.
2. (F90, 91, 92, 93 & 94) Check the contacts of Micro-Switch on latch motor assembly. If
contacts are open when motor cam depresses switch, replace Lock Motor Assembly.
3. (F90, 91, 92, 93 & 94) Check for binding of the Latch Cam, Lock Motor Rod & Lock
Motor Cam.
4. If all situations above do not solve probem, replace EOC.
IF LATCH MOTOR DOES NOT RUN
1. (F90, 91, 92, 93 & 94) Check to see if Lock Motor Coil is open. If open, replace Lock
Motor Assembly.
2. (F92, 93 & 94) Check oven door Light Switch - if open, replace Switch.
3. If all situations above do not solve probem, replace EOC.
AVIS : Cette che de réparation a été conçue pour être utilisée par des
personnes qui possèdent une formation en mécanique et en électricité
ainsi qu’un niveau de connaissance de ces sujets jugé généralement ac-
ceptable dans le domaine de la réparation. Le fabricant ne peut être tenu
responsable des blessures ou des dommages que l’utilisation de cette
che pourrait entraîner.
PROCÉDURES D’ENTRETIEN SÉCURITAIRES
L’observation de procédures d’entretien sécuritaires est importante pour éviter
les blessures ou les dommages matériels. La section suivante présente des
exemples de procédures d’entretien sécuritaires, mais sans s’y limiter.
1. Avant de réparer ou de déplacer l’appareil, débranchez-le, mettez le
disjoncteur du circuit à la position ARRÊT ou enlevez le fusible.
2. Ne modiez jamais l’installation d’un dispositif de sécurité
3. MISE À LA TERRE : Le code de couleur standard pour les ls de
mise à la terre est VERT ou VERT RAYÉ JAUNE. Les conducteurs
de mise à la terre ne doivent pas être utilisés comme des conduc-
teurs normaux. Il est extrêmement important que le technicien en
entretien rétablisse tous les dispositifs de mise à la terre avant
de terminer la réparation. Le non-respect de cette recommanda-
tion entraînera un risque d’accident.
4. Avant de remettre l’appareil en service, assurez-vous que :
• Toutes les connexions électriques sont correctes et sécuritaires.
• Tous les conducteurs sont couverts et à l’abri de rebords coupants,
de composants qui atteignent de hautes températures et de pièces
mobiles.
IMPORTANT
N’ENLEVEZ P
AS CE SAC OU NE
DÉTR
UISEZ P
AS SON CONTENU
CONTIENT LES SCHÉMAS DE CÂBLAGE ET
LES INFORMATIONS DE RÉPARATION
REMETTRE LE CONTENU
DANS LE SAC
Résistance (ohms)
1 000 ± 4,0
1 091 ± 5,3
1 453 ± 8,9
1 654 ± 10,8
1 852 ± 13,5
2 047 ± 15,8
2 237 ± 18,5
2 697 ± 24,4
Circuit ouvert/résistance infinie
ÉCHELLE DU DÉTECTEUR DE TEMPÉRATURE
À RÉSISTANCE
Température °F (°C)
32 ± 1,9 (0 ± 1,0)
75 ± 2,5 (24 ± 1,3)
250 ± 4,4 (121 ± 2,4)
350 ± 5,4 (177 ± 3,0)
450 ± 6,9 (232 ± 3,8)
550 ± 8,2 (288 ± 4,5)
650 ± 9,6 (343 ± 5,3)
900 ± 13,6 (482 ±7,5)
Circuit de la sonde mise à la
terre à la caisse
D
É
TECTEUR DE TEMP
É
RATURE
À
R
É
SISTANCE
p/n 808533108 FR (1712)
FICHE DE RÉPARATION
Cuisinières au gaz avec régulateur de four électronique ES 300/330
• Tous les éléments chauffants, connecteurs, bornes non isolées,
etc. sont à une distance adéquate de tout panneau ou de pièce
métallique.
• Toutes les connexions à la terre (à l’intérieur de l’appareil et à
l’extérieur) ont été correctement remises en place.
CALIBRATION DU FOUR
Réglez le régulateur électronique de four pour une cuisson normale à 177
°C (350 °F). Vous devez obtenir une température moyenne de four après 5
cycles. Appuyez sur Clear/Off/Cancel pour arrêter la cuisson.
AJUSTEMENT DE LA TEMPÉRATURE
1. Réglez le régulateur pour une cuisson à 285 °C (550 °F).
2. Dans les 5 secondes suivant le réglage à 285 °C (550 °F), appuyez
sur la touche de cuisson et maintenez-la enfoncée pendant 15 sec-
ondes jusqu’à ce que vous entendiez un bip (la maintenir enfoncée
plus longtemps pourrait faire retentir l’alarme de court-circuit du
clavier F11).
3. L’écart de calibration devrait s’afcher.
4. Utilisez les touches à incrément pour augmenter ou diminuer la
température du four de 2 °C (35 °F) par intervalles de 1 °C (5 °F).
5. Une fois que l’écart désiré est réglé (-19 à 19 °C / -35 à 35 °F),
appuyez sur Clear/Off/Cancel.
Remarque: La modication de la calibration s’applique au mode de cuisson
normal. Les ajustements n’affectent pas la température du cycle d’autonettoy-
age.
RÉGULATEUR ÉLECTRONIQUE DU FOUR (vue arrière)
P5
LAMPE
DU FOUR
INDIC. DE
CUISSON
RAPIDE
MOTEUR DU
LOQUET DU
VERROU
GRIL
CUISSON
VENT. DE
CUISS. RAPIDE
SPEED BAKE
** = some models.
**
CIRCUIT ANALYSIS MATRIX
(some
models)
MDL
(some models)
Connexions P5 du régulateur électronique de four
INTERR. DE CUISSON À
CONVECTION (certains modèles)
INTERR. DE CUISSON À
CONVECTION (certains modèles)
SONDE DE TEMPÉRATURE
SONDE DE TEMPÉRATURE
INTERR. DE PORTE
INTERR
. VERROU DU LOQUET MOTORISÉ DE LA PORTE
INTERR.
DE PORTE
LAMPE
DU FOUR
LOQUET
MOTORISÉ
DE LA PORTE
MOTEUR DU VENT.
DE
CUISSON À CONV.
(certains modèles)
VOYANT DE CUISSON À CONVECTION
(certains modèles)
CUISSON
GRIL
General Troubleshooting SchematicGeneral Troubleshooting Diagram
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Frigidaire FFGF3054TS Information produit

Taper
Information produit
Ce manuel convient également à

dans d''autres langues