Infiniton TEC-100 Le manuel du propriétaire

Catégorie
Chauffe-eau
Taper
Le manuel du propriétaire
The diagram above is just for reference. Please take the
appearance of the actual product as the standard.
Instruction Manual
For Model: TEC-50
TEC-80
TEC-100
1
The installation and maintenance has to be carried out by qualified professionals or authorized
technicians.
The manufacturer shall not be held responsible for any damage or malfunction caused by
wrong installation or failing to comply with following instructions included in this pamphlet.
TABLE OF CONTENTS
TITLE PAGE
1.Cautions ...........................................................................................................................(2)
2.Product introduction .........................................................................................................(3)
3.Unit installation .................................................................................................................(5)
4.Methods of using ..............................................................................................................(7)
5.Maintenance.....................................................................................................................(7)
6.Troubleshooting................................................................................................................(8)
7.Produce information with EU regulation ...........................................................................(9)
General Remark
1
The water heater is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instructions concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the heater.
The wall in which the electrical water heater is installed must be able to bear the load more than
two times of the heater filled fully with water without distortion and cracks. Otherwise, other
strengthening measures must be adopted.
The supply socket must be earthed reliably. The installation height of the supply socket must not
be lower than 1.8m. The rated current of the socket must not be lower than 16A. The socket and
plug must be kept dry to prevent electrical leakage. If the flexible power supply cord is damaged, the
special supply cord provided by the manufacturer must be selected, and replaced by the professional
maintenance personnel.
The maximum inlet water pressure is 0.5MPa; the minimum inlet water pressure is 0.1MPa, if this
is necessary for the correct operation of the appliance.
When using the heater for the first time (or the first use after maintenance), the heater can not be
switched on until it has been filled fully with water. When filling the water, at least one of the outlet
valves at the outlet of the heater must be opened to exhaust the air. This valve can be closed after
the heater has been filled fully with water.
The pressure relief valve attached with the heater must be installed at the cold water inlet of this
heater, and make sure it is not exposed in the foggy. The water may be outflowed from pressure
relief valve, so the outflow pipe must open wide in the air. In order to drain away the water inside
the inner container, it can be drained away from the pressure release valve. Twist the thread screw
of the pressure release valve off, and lift the drain handle upwards(See Fig.1) . The drainage pipe
connected to the pressure release hole must be kept sloping downwards and in a frost-free
environment. The water may drip from the discharge pipe of the pressure-relief device and that this
pipe must be left open to the atmosphere.
During heating, there may be drops of water dripping from the pressure release hole of the
pressure relief valve, this is a normal phenomenon. The pressure release hole shall not be blocked
under no circumstances, otherwise, the heater may get damaged, even resulting in accidents. If
there is a large amount of water leak, please contact customer care center for repair.
The pressure relief valve need to be checked and cleaned regularly, so as to make sure it will not
be blocked.
Since the water temperature inside the heater can reach up to 75, the hot water must not be
exposed to human bodies when it is initially used. Adjust the water temperature to a suitable
temperature to avoid scalding.
If any parts and components of this electrical water heater are damaged please contact customer
care center for repair.
Before installing this water heater,check and confirm that the earthing on the supply socket is
reliably grounded. Otherwise, the electrical water heater can not be installed and used. Do not use
extension boards. Incorrect installation and use of this electrical water heater may result in serious
injuries and loss of property.
Special Cautions
1. CAUTIONS
2
3
2. PRODUCT INTRODUCTION
2.2 Technical Performance Parameters
Model
Rated
Voltage
(ACV)
IPX4
750.75220-240200050
TEC-50
Rated
Power
(W)
Volume
(L)
Rated
Pressure
(MPa)
Max Of Water
Temperature
(°C)
Protection
Class
Waterproof
Grade
I
IPX4
750.75220-240200080
TEC-80 I
IPX4
750.75220-2402000100
TEC-100 I
(Fig.1)
Thread screw
Drain handle
Pressure release hole
Hot water Cold water
Pressure
relief valve
2.1 Nomenclature
is the product code of the storage electric water heater;
is the capacity (L);
-
TEC
A
B
C
D
385
200
755
385
TEC-50
450
200
796
450
TEC-80
450
200
896
450
TEC-100
4
2.3 Brief introduction of product structure
2.4 Internal Wire Diagram
(Note:All dimensions are in mm)
Thermometer
Hot water
outlet
Cold water inlet
Inner tank
Thermal
insulation
Heating
element
Shell
Power
cord
WIRING DIAGRAM
A
BC
D
Temperature adjusting knob
Heating indicator light
On/Off
Power indicator light
Anodo
E
N
L
QQ 0
Heating Element
Thermal
Cut Out Thermostat Switch
Brown
Blue
Yellow/Green
Heating indicator light
Power supply
indicator light
5
3.2 Pipelines Connection
3.1 Installation Instruction
3. UNIT INSTALLATION
The dimension of each pipe part is G1/2” ; The massive pressure of inlet should use Pa as the
unit; The minimum pressure of inlet should use Pa as the unit.
Connection of pressure relief valve with the heater on the inlet of the water heater.
In order to avoid leakage when connecting the pipelines, the rubber seal gaskets provided with
the heater must be added at the end of the threads to ensure leak proof joints (see Fig.4).
If the bathroom is too small, the heater can be installed at another place. However, in order to
reduce the pipeline heat losses, the installation position of the heater shall be closed to the
location shall be as near as possible to the heater.
Install the supply socket in the wall. The supply socket be 220V. It is recommended to placed the
socket on the right above the heater. The height of the socket to the ground shall not be less than
1.8m (see Fig.3). If there is fault on power cable, it should be replaced by the manufacturers,
agencies or qualified person who is able to do this so as to ensure the safety.
This electrical water heater shall be installed on a solid wall. If the strength of the wall cannot bear
the load equal to two times of the total weight of the heater filled fully with water, it is then
necessary to install a special support.
Incase of hollow bricks wall, ensure to fill it with cement concrete completely.
After selecting a proper location, determine the positons of the two install holes used for
expansion bolts with hook, Make two holes in the wall with the corresponding depth by using a
chopping bit with the size matching the expansion bolts attached with the machine, insert the
screws, make the hook upwards, tighten the nuts to fix firmly, and then hang the electrical water
heater on it (see Fig.2).
(Fig.2)
Expansion bolt (with hook)
(Fig.3)
N (Blue) Ground
L (Brown) E (Yellow/Green)
≥1.8m
6
NOTE
Please be sure to use the accessories provided by our company to install this electric
water heater. This electric water heater can not be hung on the support until it has been
confirmed to be firm and reliable. Otherwise, the electric water heater may drop off from
the wall, resulting in damage of the heater, even serious accidents of injury. When
determining the locations of the bolt holes, it shall be ensured that there is a clearance
not less than 0.2m on the right side of the electric heater, to convenient the maintenance
of the heater, if necessary.
If the users want to realize a multi-way supply system, refer to the method shown in fig.5 for
connection of the pipelines.
(Fig.4)
Hot water outlet Cold water inlet
Pressure relief valve
Pressure release hole
Joint screw for cold water inlet
Adjusting handle for
mixing valve
Rubber seal gaskets Rubber seal gaskets
Screw for hot water outlet
Shower nozzle
(Fig.5)
Pressure relief valve
Water inlet valve
Water inlet valve
Running water pipe
Mixing valve
Water pool
Triple joint
Shower nozzle
Hot
water
outlet
Cold
water
inlet
Main machine
Power cord
Power cord
7
NOTE
4. METHODS OF USING
During normal operation, the inlet valve shall be always kept open.
First, open any one of the outlet valves at the outlet of the water heater, then, open the inlet
valve. The water heater gets filled with water. When water flows out of the outlet pipe it implies
that the heater has been filled fully with water, and the outlet valve can be closed.
Insert the supply plug into the socket
Rotate the temperature adjusting knob, the “HEATING” indicator will light up. According to the
marking on the knob to increase or decrease the setting temperature The thermostat will
automatically control the temperature. When the water temperature inside the heater has
reached the set temperature, it will switch off automatically and light off the “Heating” indicator.
When the water temperature falls below the set point, the heater will be turned on automatically
to restore the heating, the indicator will light up again.
Check the power plug and outlet as often as possible. Secure electrical contact and also proper
grounding must be provided. The plug and outlet must not heat excessively.
If the heater is not used for a long time, especially in regions with low air temperature(below 0),
it is nessary to drain water from the heater to prevent damage of the water heater, due to water
freezing in the internal tank.(Refer Cautions in this manual for the method to drain away the water
from the inner container).
To ensure long reliable water heater operation, it is recommended to regularly clean the internal
tank and remove deposits on the electric heating element of the water heater, as well as check
condition (fully decomposed or not) of the magnesium anode and, if necessary, replace it with a
new one in case of full decomposition.Tank cleaning frequency depends on hardness of water
located in this territory. Cleaning must be performed by special maintenance services. You can
ask the seller for address of the nearest service center.
5. MAINTENANCE
WARNING
Before doing any maintenance, please cut off the power supply.
!
The water heater is equipped with a thermal switch, which cuts off power supply of the heating element
upon water overheating or its absence in the water heater. If the water heater is connected to the mains,
but water is not heated and the indicator doesn’t light up, then the thermal switch was switched off or not
switched on. To reset the water heater to the operating condition, it is necessary to:
1. De-energize the water heater, remove the plate of the side/lower cover.
2. Press the button, located at the center of the thermal switch, see Fig.6;
3. If the button is not pressed and there is no clicking, then you should wait until the thermal switch
cools down to the initial temperature.
8
6. TROUBLESHOOTING
NOTE
Parts illustrated in this use and care manual are indicative only, parts provided with the
product may differ with illustrations.This product is intended for household use only.
Specifications are subject to change without notice.
Failures Reasons Treatment
The heating indicator
light is off.
Failures of the temperature
controller.
Contact Assistance Service
helping for repair.
Contact Assistance
service helping for repair.
No water coming out
of the hot water outlet.
The water temperature
is too high.
Water leak.
1. The running water supply
is cut off.
2. The hydraulic pressure is
too low.
3. The inlet valve of running
water is not open.
1. Wait for restoration of
running water supply.
2. Use the heater again
when the hydraulic
pressure is increased.
3. Open the inlet valve of
running water.
Failures of the temperature
control system.
Seal problem of the joint of
each pipe. Seal up the joints.
WARNING
Non-professionals are not allowed to disassemble the thermal switch to reset.
Please contact professionals to maintain. Otherwise our company will not take
responsibility if any quality accident happens because of this.
!
(Fig.6)
Manual reset button
9
7. Produce information with EU regulation
Description tinU eulaV retemaraP
k-Value k
Smart control compliance smart
Smart control factor SCF
Conversion coefficient CC
Ambient correction term Qcor kWh
Referenct energy Qref kWh
Useful energy content QH2O kWh
Correction ratio of reference and useful energy Qref/QH2O kWh
Daily electricity consumption (measured) Qtest_elec kWh
Water temperature at the beginning of the 24h measurement
cycle T3
Water temperature at the end of the 24h measurement cycle T5
Storage volume Mact kg
Storage volume Cact L
Daily electricity consumption (corrected) Qelec kWh
that correspond to the water heating efficiency class
The product fulfills and corresponds to the requirements of the commission regulation
standards (No 814/2013) for electrical storage water heater and achieved a water
heating energy efficiency of
The evaluation of the result of this report with respect of conformity with the related
commission regulation (No 812/2013 and 814/2019) is only a part of the conformity
assessment to achieve the ErP-Label.
Electricity consumption Qelec water heating energy efficiency ηwh and mixed water
at 40 V40
“C
ηwh=36.1%
Water heating energy efficiency ηwh
Annual Electricity Consumption AEC kWh
Water heating energy efficiency class
Description Parameter Value Unit
Water temperature without tapping Tset
Average water temperature of outlet warm water θ'p
Average water temperature of inlet cold water θc
Normalised value of the average temperature θp
Volume that delivered water of at least 40 V40exp L
Calculated volume that delivered hot water of at least 40 V40 L
The electrical storage water heater TEC-50 of the company MEGAEXIT S.L. was
tested with a declared load profile of the size “M
In accordance with Annex II Enercy Efficiency Classes article 1 of the commission
regulation (No 812/2013)
0
2.5
0
5.845
50.1
50.1
6.662
36.1
1422
C
74
67.2
10.4
67.2
40
76
0.23
-0.470
74.6
5.944
0.983
6.804
74.1
10
The electrical storage water heater TEC-80 of the company MEGAEXIT S.L. was
tested with a declared load profile of the size “M
Description tinU eulaV retemaraP
k-Value k
Smart control compliance smart
Smart control factor SCF
Conversion coefficient CC
Ambient correction term Qcor kWh
Referenct energy Qref kWh
Useful energy content QH2O kWh
Correction ratio of reference and useful energy Qref/QH2O kWh
Daily electricity consumption (measured) Qtest_elec kWh
Water temperature at the beginning of the 24h measurement
cycle T3
Water temperature at the end of the 24h measurement cycle T5
Storage volume Mact kg
Storage volume Cact L
Daily electricity consumption (corrected) Qelec kWh
that correspond to the water heating efficiency class
The product fulfills and corresponds to the requirements of the commission regulation
standards (No 814/2013) for electrical storage water heater and achieved a water
heating energy efficiency of
In accordance with Annex II Enercy Efficiency Classes article 1 of the commission
regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with the related
commission regulation (No 812/2013 and 814/2019) is only a part of the conformity
assessment to achieve the ErP-Label.
Electricity consumption Qelec water heating energy efficiency ηwh and mixed water
at 40 V40
“C
ηwh=36.2%
Water heating energy efficiency ηwh
Annual Electricity Consumption AEC kWh
Water heating energy efficiency class
Description Parameter Value Unit
Water temperature without tapping Tset
Average water temperature of outlet warm water θ'p
Average water temperature of inlet cold water θc
Normalised value of the average temperature θp
Volume that delivered water of at least 40 V40exp L
Calculated volume that delivered hot water of at least 40 V40 L
5.845
0.23
0
0
2.5
-0.464
5.948
0.983
6.806
57.9
58.3
80.1
80.1
6.652
36.2
1420
C
58
58.1
10.4
58.1
56
90
11
Description tinU eulaV retemaraP
k-Value k
Smart control compliance smart
Smart control factor SCF
Conversion coefficient CC
Ambient correction term Qcor kWh
Referenct energy Qref kWh
Useful energy content QH2O kWh
Correction ratio of reference and useful energy Qref/QH2O kWh
Daily electricity consumption (measured) Qtest_elec kWh
Water temperature at the beginning of the 24h measurement
cycle T3
Water temperature at the end of the 24h measurement cycle T5
Storage volume Mact kg
Storage volume Cact L
Daily electricity consumption (corrected) Qelec kWh
that correspond to the water heating efficiency class
The product fulfills and corresponds to the requirements of the commission regulation
standards (No 814/2013) for electrical storage water heater and achieved a water
heating energy efficiency of
The evaluation of the result of this report with respect of conformity with the related
commission regulation (No 812/2013 and 814/2019) is only a part of the conformity
assessment to achieve the ErP-Label.
Electricity consumption Qelec water heating energy efficiency ηwh and mixed water
at 40 V40
“C
ηwh=36.0%
Water heating energy efficiency ηwh
Annual Electricity Consumption AEC kWh
Water heating energy efficiency class
Description Parameter Value Unit
Water temperature without tapping Tset
Average water temperature of outlet warm water θ'p
Average water temperature of inlet cold water θc
Normalised value of the average temperature θp
Volume that delivered water of at least 40 V40exp L
Calculated volume that delivered hot water of at least 40 V40 L
The electrical storage water heater TEC-100 of the company MEGAEXIT S.L. was
tested with a declared load profile of the size “M
In accordance with Annex II Enercy Efficiency Classes article 1 of the commission
regulation (No 812/2013)
5.845
0.23
0
0
2.5
-0.489
5.951
0.982
6.945
58.4
59.5
100.8
100.8
6.695
36.0
1427
C
58
55.8
10.3
55.8
72
110
The product is subject to change without notice.
Please keep this manual properly.
This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the
hazards involved.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without
supervision.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
Warning: If the surface is cracked, switch off the appliance to
avoid the possibility of electric shock.
Metallic objects such as knives, forks, spoons and lids
should not be placed on the surface since they can get hot
A steam cleaner is not to be used.
Do not use a steam cleaner to clean your cooktop.
The appliance is not intended to be operated by means of an
external timer or separate remote-control system.
WARNING: Danger of fire: do not store items on the cooking
surfaces.
The cooking process has to be supervised. A short term
cooking process has to be supervised continuously.
WARNING: Unattended cooking with fat or oil can be
dangerous and may result in fire. NEVER try to extinguish a
fire with water, but switch off the appliance and then cover
flame e.g. with a lid or a fire blanket.
CE Certificate
It has been determined that this product complies with the LOW VOLTAGE directive (2006/95/ec), Electromagnetic
Compatibility directive (2004/108/EC), and RoHS directive.
For more information related to declarations and certificates of conformity, please contact us through the mail
[email protected] and in the web www.infiniton.es
TECHNICAL SERVICE
If you have any questions regarding this device, please contact us: [email protected] and www.infiniton.es
You can also contact our official technical service - MEGAEXIT, S.L
tel: (+34) 954 087 169
Repairs e-mail: [email protected]
www.megaexit.com
O diagrama acima é apenas para referência.
Assuma a aparência do produto real como a aparência padrão.
Manual de Instruções
Para o Modelo: TEC-50
TEC-80
TEC-100
1
A instalação e manutenção devem ser desempenhadas por profissionais qualificados ou
técnicos autorizados.
O fabricante não será responsabilizado por quaisquer danos ou avarias provocadas por uma
instalação incorreta ou que não cumpre com as instruções incluídas neste panfleto.
Para obter diretrizes de manutenção e instalação mais detalhadas, consulte os capítulos abaixo.
ÍNDICE
TÍTULO PAGINA
1.Precauções ......................................................................................................................(2)
2.Introdução ao produto ......................................................................................................(3)
3.Instalação de unidade ......................................................................................................(5)
4.Métodos de utilização.......................................................................................................(7)
5.Manutenção......................................................................................................................(7)
6.Resolução de problemas..................................................................................................(8)
7.Informação de produto segundo a Regulamentação EU ................................................(9)
Comentários Gerais
2
Antes de instalar este aquecedor de água, verifique e confirme que a tomada possui uma ligação
à terra fiável. Caso contrário o aquecedor de água elétrico não pode ser instalado e utilizado. Não
utilize extensões. A instalação e utilização incorreta deste aquecedor de água elétrico podem
resultar em ferimentos graves ou perda de propriedade.
1. PRECAUÇÕES
O aquecedor de água não está concebido para ser utilizado por pessoas (incluindo crianças) com
capacidades físicas, mentais ou sensoriais reduzidas, ou sem experiência ou conhecimento, a
menos que sejam supervisionadas ou instruídas sobre a sua utilização por uma pessoa
responsável pela sua segurança. As crianças devem ser supervisionadas para assegurar que não
brincam com o aquecedor.
A parede na qual o aquecedor de água elétrico está instalado deve ser capaz de suportar uma
carga de mais de duas vezes o peso do aquecedor completamente cheio de água sem provocar
distorções e fissuras. Caso contrário devem ser adotadas outras medidas de reforço.
A tomada deve possuir uma ligação á terra fiável. A altura de instalação da tomada não deve ser
inferior a 1,8 m. A corrente nominal da tomada deve ser inferior a 16 A. A tomada e a ficha devem
ser mantidas secas para impedir a fuga elétrica. Se o cabo flexível de alimentação for danificado,
o cabo de alimentação especial fornecido pelo fabricante deve ser selecionado e substituído por
pessoal de manutenção profissional.
A pressão de entrada máxima de água é de 0,5 Mpa; a pressão de entrada mínima de água é de
0,1 Mpa, se tal for necessário para o correto funcionamento do aparelho.
Ao utilizar o aquecedor pela primeira vez (ou a primeira utilização após a manutenção), não deve
ligar o aquecedor até este estar cheio de água. Ao encher com água, pelo menos uma das
válvulas de saída na saída do aquecedor deve ser aberta para permitir a saída de ar. Esta válvula
pode ser encerrada após o aquecedor ter sido cheio com água.
A válvula de alívio de pressão anexada ao aquecedor deve ser instalada na entrada de água fria
do aquecedor e certifique-se de que não está exposta ao vapor. A água pode ser escoada a partir
da válvula de descompressão, logo o tubo de escoamento deve estar aberto para o ar livre. Para
drenar a água no interior do recipiente interior pode ser utilizada a válvula de alívio de pressão.
Rode o parafuso roscado da válvula de alívio de pressão e eleve a alavanca de drenagem para
cima (Ver Fig. 1). O tubo de drenagem ligado ao orifício de alívio de pressão deve ser mantido
inclinado para baixo e num ambiente sem gelo. A água pode pingar do tubo de descarga do
aparelho de alívio de pressão e este tubo não deve ser deixado aberto para o ar livre.
Durante o aquecimento podem surgir gotas de água que pingam do orifício de alívio de pressão
da válvula de alívio de pressão, este fenómeno é normal. O orifício de alívio de pressão não deve
ser bloqueado em nenhuma circunstância, caso contrário o aquecedor pode ficar danificado,
podendo até resultar em acidentes. Se existir uma fuga de água em grandes quantidades,
contacte o centro de apoio ao cliente para reparações.
É necessário verificar e limpar regulamente a válvula de alívio de pressão para que esta não fique
bloqueada.
Visto a temperatura da água no interior do aquecedor poder alcançar 75º C, a água quente não
deve ser exposta a corpos humanos quando utilizada inicialmente. Ajuste a temperatura da água
para um valor adequado para evitar escaldamento.
Se quaisquer peças ou componentes deste aquecedor de água elétrico forem danificadas,
contacte o centro de apoio ao cliente para reparações.
Precauções Especiais
3
2. INTRODUÇÃO DE PRODUTO
2.1 Nomenclatura
-
é o código de produto do aquecedor de água elétrico de armazenamento;
é a capacidade (L);
Modelo
Tensão
Nominal
(V CA)
IPX4750.75220-240200050TEC-50
Potência
Nominal
(W)
Volume
(L)
Pressão
Nominal
(MPa)
Temperatura
Máxima
da Água (°C)
Classe de
Proteção
Grau de
Resistência
à Água
2.2 Parâmetros de Desempenho Técnico
I
IPX4750.75220-240200080TEC-80 I
IPX4750.75220-2402000100
TEC-100
I
(Fig.1)
Parafuso roscado
Alavanca de drenagem
Orifício de alívio de pressão
Água quente Água fria
Válvula de alívio
de pressão
TEC
4
2.3 Breve introdução à estrutura de produto
2.4 Diagrama de Cablagem Interna
DIAGRAMA DE CABLAGEM
(Nota: As dimensões AII estão em mm)
A
B
C
D
385
200
755
385
TEC-50
450
200
796
450
TEC-80
450
200
896
450
TEC-100
Termómetro
Saída de
água quente
Entrada
de água fria
Luz indicadora de energia
Reservatório
interior
Isolamento
térmico
Elemento de
aquecimento
Ânodo
Luz indicadora
de aquecimento
Cabo de
alimentação
Shell
A
BC
D
Botão de ajuste de temperatura
On/Off
Proteção
Térmica Termostato
Luz Indicadora
de Alimentação
Elemento de
Aquecimento
Castanho
Azul
Amarelo/Verde
E
N
L
QQ 0
Switch
Indicador de
energia
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57

Infiniton TEC-100 Le manuel du propriétaire

Catégorie
Chauffe-eau
Taper
Le manuel du propriétaire