Westinghouse R6GE Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

IMPORTANT! Please read all information in this manual thoroughly and become familiar with the capabilities and
use of your appliance before attempting to operate or maintain this unit. Keep this literature where you have easy
access to it in the future. If a problem occurs, check the instructions and follow recommendations given. If these
suggestions don’t eliminate your problem, call your servicing contractor. Do not attempt to service this unit yourself!
Under no circumstances should the appliance owner attempt to install and/or service this equipment. Some local
codes require licensed installation / service personnel for this type of equipment. Improper service, adjustment, or
maintenance may cause explosion, fi re, electrical shock or other hazardous conditions which may result in personal
injury or property damage.
Single Package Gas Heating / Electric Cooling Unit
USER’S MANUAL
13 SEER MODELS
DO NOT DESTROY. PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call
the fi re department.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury or property
damage.
Installation and service must be performed
by a qualifi ed installer, service agency or the
gas supplier.
Do not store or use gasoline or other
ammable vapors and liquids in the vicinity
of this or any other appliance.
2
GENERAL INFORMATION
This gas heating / electric cooling unit has been
designed and built to provide many years of safe and
dependable comfort, providing it is properly installed
and maintained. With regular maintenance, this unit will
operate satisfactorily year after year. Abuse, improper
use, and/or improper maintenance can shorten the life
of the appliance and create unsafe hazards. A regular
service and maintenance schedule should be established
to ensure effi cient and safe operation of the unit. See
System Maintenance on pages 3 - 4.
To achieve optimum performance and minimize equipment
failure, it is recommended that periodic maintenance be
performed on this unit. The ability to properly perform
maintenance on this equipment requires certain
mechanical skills and tools. Please consult your dealer for
maintenance information and availability of maintenance
contracts.
WARNING:
To avoid possible equipment damage, re,
or death, the following instructions must be
observed regarding unit location, combustion
air requirements, and operational procedures.
Gas Heating / Electric Cooling Unit Location
The area around the gas heating/electric cooling unit
and the vicinity of any other gas appliances must be kept
clear and free of combustible materials, gasoline, and
other fl ammable vapors and liquids. Do not store or use
ammable items such as paint, varnish, or strippers in
the vicinity of the unit.
Do not use the area around the unit as a storage area. This
area must be kept clean and clear of loose or exposed
insulation materials. Examine the unit’s area when it is
installed or when insulation is added, since some insulation
materials may be combustible.
Do not use this appliance if any part has been under water.
Immediately call a qualifi ed service technician to inspect
the unit and to replace any part of the control system and
any gas control which has been under water.
Familiarize yourself with the controls that shut off the
gas and electrical power to the unit. If the unit is to be
shut down for an extended period of time, turn off both
the gas and electrical power. For your safety always turn
off both the gas and electrical power before performing
service or maintenance on the furnace. If the gas supply
to the unit must be shut off, refer to the gas valve label
(Figure 3, page 5).
Combustion Air Supply
The gas heating/electric cooling unit needs an adequate
supply of combustion and ventilation air for proper and safe
operation. Do not block or obstruct air openings on the unit
or air openings supplying the area where it is installed.
If the unit is operated with inadequate combustion air
supply, the fl ame roll-out control switch located above
the burners will open, turning off the gas supply to the
burners. The fl ame roll-out control is a manual reset
device. Do not attempt to reset this device yourself! Call
your servicing contractor.
WARNING:
Combustion air must not be drawn from a
corrosive atmosphere.
To maximize heat exchanger life, the combustion air
must be free of chemicals which form corrosive acidic
compounds in the combustion gases.
IMPORTANT NOTE: Do not store any chemicals with
ammable or caustic vapors near the vent termination.
Some examples of these chemicals are:
• Gasoline/Kerosene
• Permanent wave solutions
• Chlorinated waxes and cleaners
• Chlorine based swimming pool chemicals
• Water softening chemicals
• De-icing salts or chemicals
• Carbon tetrachloride
• Halogen type refrigerants
• Cleaning solvents
• Cements, glues, paint removers, varnishes, etc.
• Hydrochloric acid
• Masonry acid washing materials
• Plumbing Stack
Ductwork
WARNING:
Failure to prevent products of combustion
from being circulated into the occupied space
can create potentially hazardous conditions
including carbon monoxide poisoning that
could result in personal injury or death.
The duct connections must be physically sound and sealed
to the unit’s casing to prevent products of combustion from
entering the occupied space.
The return air and circulating air ductwork must not be
connected to any other heat producing device such as
a fi replace insert, stove, etc. Doing so may result in fi re,
explosion, personal injury, carbon monoxide poisoning,
or property damage.
3
OPERATING INSTRUCTIONS
Thermostat styles vary. Some models may not include the
AUTO mode and others will have the AUTO in place of the
HEAT and COOL. Others may include all three. Please
refer to the thermostat manufacturer’s User manual for
detailed programming instructions.
The thermostat should be mounted about 5 feet above the
oor on an inside wall and not on an outside wall or other
location where its operation may be adversely affected by
radiant heat from fi replaces, sunlight, or lighting fi xtures,
and convective heat from warm air registers or electrical
appliances.
Cooling Operation (1 or 2-Stage Operation)
1. Set the thermostat system mode to COOL and the
thermostat fan mode to AUTO. See Figure 1.
2. Set the thermostat temperature selector to the desired
temperature level. The outdoor fan, compressor, and
indoor blower will all cycle on and off to maintain the
indoor temperature at the desired cooling level.
NOTE: If the temperature level is re-adjusted, or the
system mode is reset, the fan and compressor in the
outdoor unit may not start immediately. A protective
timer circuit holds the compressor and the outdoor fan
off for approximately 5 minutes following a previous
operation or the interruption of the main electrical
power.
Heating Operation (2 Stage)
1. Set the thermostat system mode to Heat and the
thermostat fan mode to AUTO. See Figure 1.
2. Set the thermostat temperature selector to the
desired temperature level. The indoor blower and
gas heat module will cycle on and off to maintain
the indoor temperature at the desired heating level.
NOTE: On some units there is a factory set 3 minute
time delay between Stage 1 and Stage 2 heat when
Stage 2 heating is required. See Unit wiring diagram
label.
WARNING:
If overheating occurs, or the gas supply fails to
shut off, shut off the gas valve to the unit before
shutting off the electrical supply.
NOTE: This unit is equipped with a manual-reset fl ame
roll-out limit switch. This switch acts to verify that the
burner fl ame is being drawn into the heat exchanger
tubes. If the fl ame is not being drawn into the tubes, the
ame roll-out switch will open within several seconds.
When this switch opens, the gas valve will de-energize
to stop the fl ow of gas. The combustion inducer will stay
energized and continue to operate until the thermostat is
satisfi ed or the switch is closed. Do not reset the fl ame
roll-out switch before identifying and correcting the fault
condition that caused the switch to open. If the switch
will not reset or continues to open, immediately contact
a qualifi ed serviceman to identify and repair the problem.
System Shutdown
Set the thermostat system mode to OFF and the thermostat
fan mode to AUTO. See Figure 1. NOTE: The system will
not operate, regardless of the thermostat temperature
selector’s setting.
Operating the Indoor Blower Continuously
Set the thermostat fan mode to ON (or CONT on some
thermostat models). See Figure 1.
The indoor blower will start immediately, and will run
continually until the fan switch is reset to AUTO.
The continuous indoor blower operation can be obtained
with the thermostat system switch set in any position,
including OFF.
The continuous indoor blower operation is typically used to
circulate the indoor air to equalize a temperature imbalance
due to a solar load, cooking, or fi replace operation.
SYSTEM MAINTENANCE
CAUTION:
Verify all electrical power to the unit is
disconnected and the gas is shut off before
performing the following recommended
maintenance.
Proper maintenance is most important to achieve the best
performance from the appliance and should be performed
by a qualifi ed service technician at least once a year.
Follow the maintenance schedule and the instructions
below for years of safe, trouble free operation.
Do not place combustible materials on or against the
cabinet.
Do not store gasoline or any other fl ammable vapors
and liquids in the vicinity of the unit.
Annually inspect the physical support of the unit to
ensure that it is physically sound without sagging,
Figure 1. Digital Thermostat
Fan
Mode
Temperature
Selector
System
Mode
4
cracks, gaps, etc., around the base so as to provide a
seal between the support and the base.
Annually inspect the return-air connection to ensure
that it is physically sound and is still sealed to the
casing of the unit. Also inspect the unit, ductwork, and
vent system for signs of physical deterioration.
Always replace the doors on the unit after servicing.
Do not operate the unit without all doors and covers
in place. Avoid operating the unit when windows and
doors are open.
• Refer to the Maintenance Schedule (Table 1, page 8)
for recommended maintenance information.
CAUTION:
DO NOT come into contact with any of the
internal electrical components while cleaning
the unit.
Regular Cleaning
• Remove any leaves and grass clippings from the
outdoor coil. IMPORTANT: Be careful not to damage
the aluminum fi ns.
Check for and remove any obstructions such as twigs,
sticks, etc.
Clean the blower compartment regularly during the
heating and cooling seasons to remove any dust
that may have accumulated in the compartment or on
the blower and motor. Buildup of dust on the blower
and motor can create excessive loads on the motor
resulting in higher than normal operating temperatures
and possible shortened service life.
Air Filters
WARNING:
Never operate the unit without a fi lter in the
return air system. Dust and lint in the return
air can build up on the internal components,
resulting in loss of effi ciency, equipment
damage, and possible fi re risk.
This unit is not supplied with air fi lter(s) and has no means
for accommodating internal air fi lter(s). The installer is
responsible for installing a fi ltration system into the return
air duct of this system. The fi lter(s) of this system should
be checked at monthly.
It is very important to replace or clean the fi lter(s) installed
in the return air duct of this system. A clogged fi lter could
cause airfl ow related problems and reduce the overall
effi ciency of your unit. Depending upon which type of fi lter
was installed with your unit, clean (permanent) or replace
(disposable) fi lter(s) of your system at the beginning of
every heating sea son, the beginning of every cooling
season, and when an accumulation of dust and dirt are
visible on the fi lter. IMPORTANT: Replace disposable
lter(s) installed in your system only with the same
size dimensional fi lters that are being replaced. Clean
permanent fi lter(s) as described by the manufacturer.
Motor Lubrication
The motors for the circulating air blower, outdoor fan, and
combustion blower are pre-lubricated and sealed by the
manufacturer. No further oiling is required for the life of
this product.
Burner Maintenance
CAUTION:
Some components in the burner vestibule are
at high temperatures while the burners are
operating. Use caution to avoid personal injury.
Check the burner fl ames at the start of every heating
season. Set the thermostat above the room temperature.
Remove the control access panel to the unit and visually
inspect the burner assembly to make sure that the fl ame
is drawn directly into the center of the heat exchanger tube
(See Figure 2). In a properly adjusted burner assembly,
the fl ame bends up and to the left at the end of the heat
exchanger tube, and the end of the fl ame will be out of
sight around the bend. The fl ame color should be blue,
however some light yellow streaks may occur on the outer
portions of the fl ame.
Figure 2. Burner Inspection
TROUBLESHOOTING
Before you call a Technician, check the following:
Check the thermostat setting. Make sure the system
mode and temperature settings are correct.
• Check the electrical panel for tripped circuit breakers.
• Check the fi lters for dust accumulation.
Check the unit and make sure it is clean and not
covered with grass or leaves.
If the items above don’t resolve your problems, then
call your nearest service technician.
5
A. This appliance does not have a pilot. It is equipped with
an ignition device which automatically lights the burner.
Do not try to light the burner by hand.
B. BEFORE OPERATING smell all around the appliance
area for gas. Be sure to smell next to the fl oor because
some gas is heavier than air and will settle on the fl oor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone
in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fi re
department.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or move
by hand, do not try to repair it, call a qualifi ed service
technician. Force or attempted repair may result in a fi re
or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualifi ed service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
1. ATTENTION! Lire d’abord la liste des mesures de
sécurité ci-dessus.
2. Mettre le thermostat à la position minimale.
3. Couper le courant électrique qui mène à l’appareil.
4. Cet appareil ménager étant doté d’un système
d’allumage automatique, ne pas essayer d’allumer le
brûleur manuellement.
5. Retirer le panneau/volet d’accès de commande (panneau
supérieur s’il s’agit d’un modèle à deux panneaux).
6. Faire tourner le robinet à gaz dans le sens des aiguilles
d’une montre
pour l’amener sur la position OFF
(Arrêt) (Voir Figure 1).
7. Attendre cinq (5) minutes pour s’assurer de la
dissipation du gaz.
En cas d’odeur, ARRÊTER LE PROCÉDÉ. Suivre les
instructions ci-dessus (Section B). En l’absence de
toute odeur de gaz, avancer à l’étape suivante.
8. Faire tourner le robinet à gaz dans le sens inverse des
aiguilles d’une montre
pour l’amener sur la position
ON (Marche) (Voir Figure 1).
9. Remettre le panneau/volet d’accès de commande en
place (panneau supérieur s’il s’agit d’un modèle à deux
panneaux).
10. Rebrancher l’appareil sur le réseau électrique.
11. Ajuster le thermostat à la position désirée.
12. Si l’appareil ne fonctionne pas, suivre les “Directives
d’arrêt” cidessous et appeler le technicien de service.
A. Cet appareil ménager n’a pas de veilleuse. II est doté
d’un système d’allumage automatique. Ne pas essayer
d’allumer le brûleur manuellement.
B. AVANT L’USAGE. Attention à une possible odeur de
gaz surtout au niveau du plancher où les gaz les plus
lourds ont la tendance de se concentrer.
EN CAS D’ODEUR DE GAZ.
Ne mettre en marche aucun appareil électrique.
Ne toucher à aucun commutateur électrique, ne pas
employer le téléphone.
Quitter le bâtiment immédiatement et avertir la
compagnie du gaz en utili sant le téléphone d’un voisin.
A défaut de la compagnie du gaz, avertir le service des
pompiers.
C. Enfoncer ou faire tourner le robinet à gaz à la main
seulement. Ne jamais utiliser d’outils. S’il n’est pas
possible de faire tourner ou d’enfoncer le robinet à la
main, ne pas essayer de le réparer. Faire appel à un
spécialiste. Forcer ou tenter de réparer le robinet pourrait
être à l’origine d’une explosion ou d’un incendie.
D. II est déconseillé d’utiliser cet appareil en contact
prolongé avec l’eau. Faire inspecter ou remplacer
toute commande par un technicien qualifi é si un des
systèmes de contrôle du gaz s’est trouvé sous l’eau.
1. STOP! Read the safety information above on this
label.
2. Set the thermostat to the lowest setting.
3. Turn off all electrical power to the appliance.
4. The appliance’s ignition device automatically lights
the burner. Do not try to light burner by hand.
5. Remove the control access door/panel (upper door if
two-door model).
6. Move the gas control knob clockwise
to “OFF”.
(See Figure 1)
7. Wait fi ve (5) minutes to clear out any gas. Then smell
for gas, including near the fl oor. If you smell gas,
STOP! Follow “B” in above information. If you don’t
smell gas, go to the next
step.
8. Move the gas control knob
counterclockwise
to
“ON”. (See Figure 1)
9. Replace the control
access door/panel (upper
door if two-door model).
10. Turn on all electrical
power to the appliance.
11. Turn the thermostat to a desired setting.
12. If the appliance will not operate, follow the
instructions “To Turn Off Gas To Appliance” and call
your service technician or gas supplier.
7106750 (Replaces 710329A) (03/07)
1. Mettre le thermostat à la position minimale.
2. Débrancher l’appareil en prévision de la réparation.
3. Retirer le panneau/volet d’accès de commande (panneau
supérieur s’il s’agit d’un modèle à deux panneaux).
4. Faire tourner le robinet à gaz dans le sens des
aiguilles d’une montre
pour l’amener sur la
position OFF (Arrêt) Ne pas forcer (Voir Figure 1).
5. Remettre le panneau/volet d’accès de commande en
place (panneau supérieur s’il s’agit d’un modèle à deux
panneaux).
POUR VOTRE SÉCURITÉ.
À LIRE AVANT L’EMPLOI
FOR YOUR SAFETY READ
BEFORE OPERATING
1. Set the thermostat to the lowest setting.
2. Turn off all electrical power to the appliance if service is
to be performed.
3. Remove the control access door/panel (upper door if
two-door model).
4. Move the gas control knob clockwise
to “OFF”. Do
not use force. (See Figure 1)
5. Replace the control access door/panel (upper door if
two-door model).
ATTENTION! L’inobservation de ces instructions
peut entraîner un incendie ou une explosion pouvant
causer des dam mages à votre propriété à votre
personne, ou la mort.
WARNING: If you do not follow these instructions
exactly, a fi re or explosion may result causing property
damage, personal injury, or loss of life.
TO TURN OFF
GAS TO APPLIANCE
DIRECTIVES D’ARRÊT
KNOB
(ROBINET)
Figure 1
MODE D’EMPLOI
OPERATING INSTRUCTIONS
¢7106757¤
Figure 3. Gas Valve Label
6
7
708258A (Replaces 7082580)
Specifi cations & illustrations subject to change without notice or incurring obligations.
O’Fallon, MO | Printed in U.S.A. (09/10)
¢708258E¤
MAINTENANCE ITEM
FREQUENCY OF MAINTENANCE
BEGINNING OF EACH
HEATING SEASON
END OF EACH
HEATING SEASON
MONTHLY
Verify area around the unit is free of
combustible materials
XX
Verify combustion and ventilation air is
not restricted
XXX
Verify no signs of physical deterioration
of the furnace
XXX
Verify burner fl ame
X
Inspect unit support
XX
Inspect return air connections
XX
Clean or replace fi lter(s)
X
Clean blower compartment
X
Clean burner vestibule
X
Table 1. Maintenance Schedule
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Westinghouse R6GE Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues