Risco WatchOUT Guide d'installation

Taper
Guide d'installation
Portuguese Français Español Italiano
English
Dual Technology Outdoor Detector
Rivelatore da Esterno a Doppia Tecnologia
Detector Externo de Doble Tecnología
Détecteur extérieur à double technologie
Detector Externo de Dupla Tecnologia
Installation Instructions - Relay & BUS Modes
Istruzioni per l’installazione in modalità Relé e BUS
Instrucciones de Instalación - Modos Relé y BUS
Guide d'installation - Modes Relais et BUS
Instruções de Instalação - Modos Relé & BUS
2 WatchOUT DT Installationn Manual
WatchOUT DT Installation Manual 3
English
Table Of Contents
Relay Mode Installation ............................................................................................................ 4
Introduction ...............................................................................................................................4
Mounting....................................................................................................................................4
Mounting Considerations........................................................................................................ 4
Wall Mount Installation............................................................................................................ 5
Flat Mounting:......................................................................................................................... 5
45° angle Mounting (Left side mounting)................................................................................ 5
Changing Back Tamper position............................................................................................. 6
Terminal Wiring ........................................................................................................................ 6
DIP Switch Settings....................................................................................................................7
Microwave Adjustment ............................................................................................................. 7
Walk test.................................................................................................................................7
LEDs Display .............................................................................................................................. 7
Relay Mode / BUS Mode Jumper............................................................................................. 7
Standard Swivel Installation .................................................................................................... 8
Wall Mounting......................................................................................................................... 8
Swivel Conduit Mounting (using Conduit
Metal Swivel Adaptor – CSMA, Figure 6, Detail A) ................................................................ 8
Replacing a Lens ..................................................................................................................... 10
Lenses Types ....................................................................................................................... 11
Technical Specification ........................................................................................................... 12
Ordering Information ............................................................................................................. 12
BUS Mode Installation ............................................................................................................ 13
Introduction ............................................................................................................................. 13
Terminal Wiring ...................................................................................................................... 13
DIP Switch Settings..................................................................................................................13
ProSYS Programming.............................................................................................................. 14
New System Parameters......................................................................................................... 16
4 WatchOUT DT Installation Manual
Relay Mode Installation
Introduction
RISCO Group's Dual Technology Outdoor detector, WatchOUT, is a unique detector with signal
processing based on two Passive Infrared (PIR) channels and two Microwave (MW) channels.
The detector can operate as a regular relay detector connected to any control panel, or as a BUS
accessory when connected to RISCO Group's ProSYS control panel via the RS485 BUS, thus
having unique remote control and diagnostic capabilities.
The instructions describe herein, describe the WatchOUT in Relay & BUS mode.
Mounting
Mounting Considerations
If possible, avoid pointing the detector to
moving objects (swaying trees, bushes etc.)
1m - 2.7m
(3'3" - 8'9")
Optional Height: 1m – 2.7m
(3'3"-8'9")
Typical Height: 2.2m (7'2")
Default Lens: Wide angle 15m (50') 90°
(RL300)
Note:
1. For low installations, below 1.7m (5'6") in which
pet immunity is required, use the supplied
RL300F lens (low wall or fence installations).
2. The detector's pet immunity (height of an animal,
no weight limitation), is up to 70 cm (2'4"), when
installing the detector at 2.2m (7'2"). If the
installation is bellow the height mentioned
above, the Pet Immunity decreases accordingly;
every 10 cm (4") decrease in installation height
leads to 10 cm (4") decrease in pet imunity.
Out of
Detection Range
Keep distance of
minimum 5m (16')
from moving objects
5m (16')
Ensure any objects do not obstruct the field of
view for both technologies. Pay attention to
growing trees or bushes, plants with big
moving leaves etc
For installations with extensive vehicle traffic or targets beyond
the required detection range, it is recommended to adjust the
MW sensitivity and/or to tilt the detector down.
Note:
Tilting the detector down may reduce the pet immunity
For optimum detection, select a
location that is likely to
intercept an intruder moving
across the coverage pattern at
a 45° trajectory.
WatchOUT DT Installation Manual 5
English
Wall Mount Installation
Figure 1
C1
Figure 2
I1
Figure 3
Tamper
Lever
A
T5
T1
B2
W9
B3
W2
B
L1
T3
B1
L2
W3
B4
R1
R2
(not visible)
T2
T6
(not visible)
T4
W5
W6
Note:
The installation knockouts numbering are marked on
the back plate.
1. Open WatchOUT front cover
(unlock C1, Figure 1).
2. Release internal base (unlock I1, Figure 2).
3. Select mounting installation as follows:
Flat Mounting:
Open knockouts on external base (Figure 3).
B1 - B4: Wall mounting knockouts
T1: Back tamper knockout
W2 / W3: wires entry knockouts
45° angle Mounting (Left side
mounting)
a. Open knockouts on external base
(Figure 3)
L1, L2: Left mounting knockouts
T3: Left tamper knockout
W5 / W6: Wire entry knockouts
b. Remove tamper spring.
c. Replace tamper bracket (Item 1) with
supplied flat tamper bracket (Item 2).
Item 1
Item 2
d. Insert Tamper lever B onto T5 and T3
and secure screw A (Figure 3).
4. Insert external wires through external base
W2, W3 (Flat Mounting) or W5, W6 (Left
side mounting) (Figure 3).
5. Secure external base to the wall.
6. Insert external wires and tamper wires
through internal base (Figure4).
7. Secure internal base to external base (lock
I1, Figure2).
8. Close the front cover (Lock C1, Figure1)
after wiring and setting DIP switches.
9. Walk test the detector.
Figure 4
Note:
For 45° right side installation use the equivalent units on the external base as follows:
Knockouts Description Left Right
Mounting Knockouts L1, L2 R1, R2
Tamper spring knockouts T1,T3 T2,T4
Tamper screw anchor T5 T6
Wiring Knockouts W5, W6 W7, W8
6 WatchOUT DT Installation Manual
Changing Back Tamper position
The back tamper is by default secured on the right
side of the internal base (rear view). If you wish to
move it to the left side (rear view), do the following
(Figure 5):
1. Remove tamper screw 1 in order to release the
tamper from position 7.
2. Ensure tamper spring 2 rests over tamper wire
base 4.
3. Ensure plastic tamper bracket 3 rests over both
2 and 4.
4. Secure tamper screw 1 into 3 over position 6.
Figure 5
Left Side
Tamper
Right Side
Tamper
3
6
1
2
4
7
5
Notes:
1. Verify that you hear a "Click" when attaching the tamper spring to the wall.
2. For pole installation, the tamper can be moved to the bottom right-hand side of the internal base.
Terminal Wiring
+-
SET/
UNSET
LEDs
ENABL
AM
YEL
FREE
ALARM
TAMPER
GREEN
FREE
DUST TEST
12VDC
N.C
N.C
WatchOUT DT - PCB
+,-
12 VDC
ALARM
N.C relay, 24VDC , 0.1A
FREE YEL
This terminal is a free pin that can be used to connect wires and EOL resistors
TAMPER
N.C relay, 24VDC , 0.1A
FREE
GREEN
This terminal is a free pin that can be used to connect wires and EOL resistors
AM
Normally closed AM relay output (
24VDC, 0.1A) indicates Anti Masking alarm or
any trouble in the detector (Not including dust/dirty lens).
Note:
When a vibration detector is installed and DIP8 is defined as Enabled this relay also opens
momentarily when vibration event occurs.
LED
ENABLE
Used to remotely control the LEDs when DIP1 is set to ON.
Enable: input is +12V OR no terminal connection
Disable: Connect the input to 0V
DUST
N.O. collector max 70 mA. Indicates that the lens is dirty and requires cleaning.
TEST
Used to perform remote alarm testing to the detector by applying 0 volts to this
terminal.
Success: Alarm relay is momentary opened.
Failure: AM relay is opened
This input enables to control Anti-masking and LEDs operation in accordance to
the system status, Set (Arm) / Unset (Disarm).
While the system is armed this feature prevents an intruder from gaining
knowledge of the detector’s status and disables Anti-masking detection.
SET/
UNSET
System Status Input Status AM Relay LEDs
Set (Arm) 0V Off Off
Unset (Disarm) 12V or no connection On* On**
* DIP7 is ON (Anti masking enabled)
** DIP1 is ON (LEDs enabled) and LEDs ENABLE input terminal is enabled
(+12V OR no terminal connection)
WatchOUT DT Installation Manual 7
English
DIP Switch Settings
12345678
ON
Factory
Default
DIP 1: LEDs operation
On: LEDs Enabled
Off: LEDs Disabled
DIP 2-3: Detection Sensitivity
Sensitivity DIP2 DIP3
Low Off Off
Mid Off On
Normal
(Default)
On Off
Maximum* On On
* In maximum sensitivity sway
recognition is disabled to achieve
maximum sensitivity
DIP 4: Alarm condition
On: PIR or MW
Off: PIR + MW
DIP 5: Detector's optics
On: Barrier / Long range
Off: Wide angle
DIP 6: Red LED /3 LED
On: Red LED only
Off: 3 LEDs
DIP 7: Anti masking operation
On: Enabled
Off: Disabled
DIP 8: Vibration detection (applicable to versions
with Vibration sensor installed)
On: Enabled
Off: Disabled
Microwave Adjustment
Adjust Microwave coverage area by using the trimmer on the PCB.
MIN
MAX
Walk test
Two minutes after applying power, walk test the protected area to
verify proper operation.
For installations on uneven surfaces slide the PCB inside the internal
base to the appropriate setting according to the desired height (1.0m,
1.5m, 2.2m, 2.7m) as printed on the bottom left corner of the PCB or
use the standard swivel accessory.
For reducing the detection range, slide the PCB up
or tilt the
swivel down
.
1.00M
1.50M
2.20M
2.70M
PCB
LEDs Display
LED State Description
Steady Indicates PIR detection
YELLOW
Flashing Indicates AM (Anti mask) detection
GREEN
Steady Indicates MW detection
Steady Indicates ALARM
RED
Flashing Indicates malfunctioned communication with ProSYS (BUS
mode only)
All LEDs
Flashing (One
after another)
Unit initialization on power up
Notes:
1. DIP-Switch 1 should be in ON position to enable LED indications.
2. Only one LED is active at any one time. For example, in the case of both PIR and MW detection, either the
steady YELLOW LED or the steady GREEN LED is displayed (the first to detect), followed by the Alarm RED
LED.
Relay Mode / BUS Mode Jumper
J-BUS jumper (located on the PCB between the red and green LEDs)
is used to define the detector’s mode of operation as follows:
Relay
Mode
BUS
Mode
8 WatchOUT DT Installation Manual
Standard Swivel Installation
The Outdoor detector packaging contains a standard swivel for flexible installation. Please follow
the instructions below for mounting the detector with the Standard Swivel:
1. Open WatchOUT front cover (Unlock C1, Figure1).
2. Release internal base (Unlock I1, Figure 2).
3. Open knockouts on external base (Figure 6, Detail B)
W1: Wires knockout
S1,S2: Knockouts for securing external base to Standard Swivel
S3: External base locking screw knockout
4. On the swivel accessory remove the required swivel cable wiring knockout S2, S7 or S9
(Figure 6, Detail A).
5. Remove back tamper from the internal base (see “Changing Back Tamper Position"
paragraph) and connect it to S5 (Figure 6, Detail A) on the Standard Swivel.
Note:
Ensure that you see the engraved UP mark on the upper front face of the swivel.
6. Select the mounting installation type as follows:
Wall Mounting
a. Insert external cable wiring through knockouts S2, S7 or S9 and extract them (including the
tamper wires) through the Swivel Wires Passage (Figure 6, Detail B).
b. Secure swivel to the wall through holes S1, S3, S6 and S8.
Swivel Conduit Mounting (using Conduit Metal Swivel Adaptor – CSMA, Figure 6, Detail A)
S1
S2
S3
S9
S8
S7 S6
S5
S4
Tamper
(see Detail C)
Swivel Wires
Passage
Tamper
Spring
Holes
Ø 21 mm
Ø 16 mm
CSMA
M1
M2
M3
M4
Detail A Detail B
S1
W1
S2
S3
Snaps
Standard Swivel
Detail C
Figure 6
Note:
The CSMA is required when wall external wiring is used and protection pipe is required. The CSMA should
be ordered separately - P/N RA300SC0000A.
a. Choose the direction upon which to mount the CSMA according to the required diameter:
16mm (0.63 inches) or 21mm (0.83 inches).
b. Insert conduit to the CSMA.
c. Secure CSMA to the wall through points (M1, M4).
d. Insert external cables and tamper wires from the conduit through the swivel wires
passage of the swivel (Figure 6, Detail A).
e. Secure swivel to the wall through holes S1, S3, S6 and S8.
WatchOUT DT Installation Manual 9
English
Note:
The Tamper spring S5 (Figure 7) should make contact with the wall through the tamper spring holes M2 or
M3 on the CSMA. Make sure to hear the tamper "Click" when connecting to the wall.
7. Insert tamper wires and external cable wiring from Standard Swivel through knockout W1 on
the external base (Figure 6, Detail B).
8. Connect the external base to the swivel using the dedicated snaps (Figure 7).
PCB
External Base
Internal Base
Angle Locking
Screw
(See Note 2)
See Detail A
Swivel to External Base
Connecting Screws
Detail A
Swivel Assy
Connecting Screw
(See Note)
Snaps
S1
W1
S2
S3
Figure 7
NOTE:
Do not open or close the Swivel Assy Screw since it is used for connecting the swivel parts only.
9. Secure external base to swivel with two screws fastened to knockouts S1 and S2 (Figure 7).
10. Insert the supplied angle locking screw from the external base through the angle locking screw
knockout S3 on the external base to the standard swivel (Figure 7).
11. Tilt and Rotate the Standard Swivel to the desired position. Once the Standard Swivel is in the
desired position, secure the angle locking screw.
12. Line up the internal base onto the external base. Insert all wiring cables through the internal
base.
13. Secure internal base to external base (Lock I1, Figure 2).
14. To readjust the Standard Swivel when the PCB is installed (Figure 7):
a. Bend down the black foam located below the RED LED on the PCB (enough to reach the
Swivel locking screw).
b. Use a Philips screwdriver to release the locking screw (see Figure 8).
c. Tilt and/or Rotate the Standard Swivel to the desired position.
d. Secure the angle locking screw.
Note:
When marks on the two movable parts are aligned (Figure 8), the Standard Swivel is in 0°
vertical /horizontal position. Each click from this position represents shifting of 5° in vertical / horizontal
position.
15. Close the front cover (Lock C1, Figure 1) and walk test the detector.
10 WatchOUT DT Installation Manual
NOTE:
The screw has to pass through External Base and locked to the swivel.
Figure 8
Replacing Lenses
1. Unlock the six screws that hold the lens holding sleeve from the back of the front cover.
2. To release the protective sleeve, gently push the lens from the external side of the front cover.
3. Disconnect the lens from the sleeve by gently pushing the lens clips that secure it to the
sleeve.
4. Replace the lens. Place the 4 clips of the lens into the matching holes on the sleeve.
5. Insert the protective sleeve back into place on the front cover. Pay attention to place the
sleeve over the sealing rubber.
6. Secure the 6 holding screws back to their place.
Lens Protecting
Sleeve
Sockets for
Lens Clips
Sleeve Locking
Screws
Lens Locking
Clips
Sealing Rubber
Front Cover
Locking Screw
WatchOUT DT Installation Manual 11
English
Lens Types
Wide angle lens (RL300) /
Low installation - Pet lens (RL300F) :
Top view
11
11
Feet
0
0
10
20
30 40 50
10
20
30
40
10
20
30
40
2468100121415
1
3
5
7
9
0
1
3
5
7
9
90°
Wide angle lens (RL300):
Side View
Typical
Installation
Height:
2.2m (7'2")
0
10
2468100121415
0
10
20
30 40 50
1
3
0
Feet
Meters
Feet
Low installation - Pet lens (RL300F) :
Side view
Feet
0
6
2468100121415
0
10
20
30 40 50
1
0
2
Meters
Feet
Typical
Installation
Height:
1.5m (5'3")
Note:
The detector's Pet Immunity (height of an animal, no weight limitation), is up to 70 cm (2'4"), when installing the
detector at 2.2m (7'2"). If the installation is bellow the height mentioned above, the Pet Immunity decreases
accordingly; every 10 cm (4") decrease in installation height leads to 10 cm (4") decrease in pet imunity.
Long range lens (RL300LR): Top view
2468100 12141618202223
0
10
20
30 40 50
60 70 75
1
0
1
0
3
3
Feet
Meters
Feet
Barrier lens (RL300B): Top view
2468100121415
0
10
20
30 40 50
1
0
1
0
3
3
Feet
Meters
Feet
Long range lens (RL300LR): Side view
0
10
1
3
0
2468100 12141618202223
Meters
0
10
20
30 40 50
60 70 75
Feet
Typical
Installation
Height:
2.2m (7'2")
Feet
Barrier lens (RL300B): Side view
2468100121415
0
10
20
30 40 50
Feet
Meters
0
10
1
3
0
Typical
Installation
Height:
2.2m (7'2")
Feet
12 WatchOUT DT Installation Manual
Technical Specification
Electrical
45mA at 12 VDC (Stand by) Current consumption (Relay Mode)
70mA at 12 VDC (MAX with LED ON)
30mA at 12 VDC (Stand by), Current consumption (BUS Mode)
55mA at 12 VDC (MAX with LED ON)
Voltage requirements 9 -16 VDC
Alarm contacts 24 VDC, 0.1A
AM contacts 24 VDC, 0.1A
Dust output Open collector 70mA max
Physical
Size:
LxWxD
220 x 115 x 123mm (8.7 x 4.5 x 4.85 in.)
Weight 0.632 Kg (1.4lb)
Environmental
RF immunity (30MHz to 2GHz): 40V/m
Operating/Storage temperature -30°C to 60°C (-22°F to 140°F)
Ordering Information
Standard Units
Part Number Description
RK315DT0000A WatchOUT DT 10.525GHz + Swivel
RK315DT00UKA WatchOUT DT 10.587GHz + Swivel
RK315DT00FRA WatchOUT DT 9.9GHz + Swivel
Note:
Each of the detectors contains a standard swivel and 3 replacement lenses (P/N engraved on the Lens) 1.7m
low installation pet (RL300F), long-range (RL300R) and barrier lens (RL300B).
Accessories Kits
Part Number Description Weight
RA300B00000A WatchOUT Barrier Swivel Kit 0.1 Kg (0.23 lb)
RA300P00000A WatchOUT Pole Adaptor Kit 0.25 Kg (0.55 lb)
RA300C00000A WatchOUT Conduit Adaptor Kit 0.6 Kg (1.27 lb)
RA300HS0000A WatchOUT Demo Housing - -
RA300SC0000A WatchOUT Swivel Metal Conduit Adaptor 1Kg (2.2 lb)
Camera Option
Part Number Description
RA300VC0001A WatchOUT Camera Cover Adaptor 1
RA300VC017NA NTSC Narrow Camera For WatchOUT
RA300VC053NA NTSC Wide Camera For WatchOUT
RA300VC053PA WatchOUT PAL Wide Camera kit
RA300VC017PA WatchOUT PAL Narrow Camera kit
RA300VPS100A WatchOUT 220V PAL Camera Power supply
RA300VPS200A WatchOUT 120V Camera Power supply
WatchOUT DT Installation Manual 13
English
BUS Mode Installation
Introduction
The information in this section relates to WatchOUT DT installation in BUS Mode only. Up to 32
BUS detectors can be installed on the ProSYS RS485 BUS, saving cabling time and enabling
remote control and diagnostics.
Terminal Wiring
+,-
Used for the connection of 12VDC power supply. Connect the (+) terminal to
the AUX RED and the (–) terminal to the COM BLK of the ProSYS terminals
YELLOW
Used for data communication with the ProSYS. Connect to the terminal to the
BUS YEL of the ProSYS
GREEN
Used for data communication with the ProSYS. Connect to the terminal to the
BUS GRN of the ProSYS
TAMPER
Used for the wiring for tamper detection, see below
LED
ENABLE
Used for the wiring for tamper detection, see below
Note:
All terminals that are not mentioned in the table above are unused.
Cover and Back Tamper
+
-
SET/
UNSET
LEDs
ENABLE
AM
YEL
FREE
ALARM
TAMPER
GREEN
FREE
DUST TEST
COM
BLK
BUS
GRN
YEL
BUS Mode:
Cover + Back tamper wiring
BACK
TAMPER (N.C)
ProSYS
Short
AUX
RED
Cover Tamper Only
+-
SET/
UNSET
LEDs
ENABLE
AM
YEL
FREE
ALARM
TAMPER
GREEN
FREE
DUST TEST
COM
BLK
BUS
GRN
YEL
BUS Mode:
Cover Tamper Wiring
ProSYS
Short
AUX
RED
Cover Tamper to Zone Input
+
-
SET/
UNSET
LEDs
ENABLE
AM
YEL
FREE
ALARM
TAMPER
GREEN
FREE
DUST TEST
COM
BLK
BUS
GRN
YEL
BUS Mode:
Cover Tamper to Zone Input
ProSYS
BUS
Short
Zone
COM
Z1 Z2
Zone
Input
AUX
RED
DIP Switch Settings
DIP Switch
Number
Description
1 - 5 Used to set the detector ID number. Set the ID number in the same way as for
any other ProSYS accessory (Refer to the ProSYS installation instruction
manual)
6 - 8 Not used
14 WatchOUT DT Installation Manual
WatchOUT ID: DIP Switches 1 - 5
ID 1 2 3 4 5 ID 1 2 3 4 5
01 OFF OFF OFF OFF OFF 17 OFF OFF OFF OFF ON
02 ON OFF OFF OFF OFF 18 ON OFF OFF OFF ON
03 OFF ON OFF OFF OFF 19 OFF ON OFF OFF ON
04 ON ON OFF OFF OFF 20 ON ON OFF OFF ON
05 OFF OFF ON OFF OFF 21 OFF OFF ON OFF ON
06 ON OFF ON OFF OFF 22 ON OFF ON OFF ON
07 OFF ON ON OFF OFF 23 OFF ON ON OFF ON
08 ON ON ON OFF OFF 24 ON ON ON OFF ON
09 OFF OFF OFF ON OFF 25 OFF OFF OFF ON ON
10 ON OFF OFF ON OFF 26 ON OFF OFF ON ON
11 OFF ON OFF ON OFF 27 OFF ON OFF ON ON
12 ON ON OFF ON OFF 28 ON ON OFF ON ON
13 OFF OFF ON ON OFF 29 OFF OFF ON ON ON
14 ON OFF ON ON OFF 30 ON OFF ON ON ON
15 OFF ON ON ON OFF 31 OFF ON ON ON ON
16 ON ON ON ON OFF 32 ON ON ON ON ON
ProSYS Programming
The following section describes the additional software programming options, added to the
ProSYS software, that concern the settings of the WatcOUT DT as a BUS detector. Up to 32 BUS
detectors can be added to the system (16 in ProSYS 16) and each of them comes at the expense
of a zone in the system.
It is recommend reading and fully understanding the ProSYS Installation and User Manuals,
before programming the WatchOUT
Notes:
The WatchOUT is compatible with the ProSYS software Version 4.xx and above.
The WatchOUT can be programmed via the U/D Software from UD Version 1.8 and above.
For maximum operation stability, it is best NOT to exceed a total of 300 meters (1000 feet) of wiring when
connecting the WatchOUT to the BUS.
Adding / Deleting the WatchOUT DT
The WatchOUT is part of a new accessory category, BUS zones. Therefore, Adding/Deleting the
WatchOUT is identical to any other accessory with the following exception:
Each BUS Zone Detector should be assigned to a Regular Zone.
Any BUS detector can be assigned to a physical wired zone or to a virtual zone.
Physical zone: Any zone on the ProSYS PCB (zones 1-8) or on a wired zone expander
(ZE08, ZE16).
Virtual zone: Any zone on a BUS zone expander defined as BZ08 or BZ16.
Notes:
Virtual BUS zones are cost effective. They enable to expand your system zones without adding physical zone
expanders.
The virtual BUS zone expander can be used only for BUS zone detectors.
To add a BUS zone expander select type BZ08 or BZ16 when adding a zone expander (Quick key [7][1][2]).
1. To Add / Delete the WatchOUT DT
1. From the installer menu enter the Add/Delete menu: Quick Key [7][1][9][5] for BUS Zones
detectors.
2. Use the
/ or / keys to position the cursor over the BUS Zone
ID number for which you want to assign (or delete) a detector.
Note:
Make sure that the detector's physical ID number is identical to the ID number you select during programming.
WatchOUT DT Installation Manual 15
English
3. Place the cursor on the TYPE field and use the / key to select ODT15 for the
WatchOUT DT detector.
4. Press
/ to confirm.
5. Repeat the process for the other BUS detectors.
2. Assigning the WatchOUT DT to a Zone
1. From the main installer menu enter Zones: One by One option (Quick key [2][1])
2. Select the zone number that you want to assign the BUS detector.
Note:
If you defined a BUS Zone Expander, select a zone number from the virtual zones (defined by the BUS zone
expander).
3. Define Partitions, Groups, Zone Type and Zone Sound.
4. In the Termination category select [5] BUS Zone followed by
/ .
The following display appears:
Z:001 LINK TO:
ID:01 TYPE=ODT15
Z:001 LINK TO:
ID:01 TYPE=ODT15
5. Select the BUS zone number to assign to the programmed zone. The type field will be
updated automatically when selecting the zone.
6. Press
/ . The loop response category is not applicable to a BUS zone and the
following display appears:
Z:001 RESPONSE:
N/A-BUS ZONE
Z:001 RESPONSE:
N/A-BUS ZONE
7. Press
/ , assign label and press / .
3. Configuring the WatchOUT DT Parameters
1. To access the WatchOUT settings option press [2][0][3] from the main installer menu. The
following display appears:
B-ZONE PRMS:
ZONE#=001 (M:ZZ)
B-ZONE PRMS:
ZONE#=001 (M:ZZ)
2. Select the zone that the BUS zone was assigned to and press
/ . You can
now program the WatchOUT parameters as follows:
Zones Miscellaneous: BUS Zone
Quick Keys Parameter Default
LEDS 3 LEDS [2][0][3][zzz]
[1]
Defines the LEDS operation mode.
Off [2][0][3][zzz]
[1][1]
Disables the LEDS operation.
Red Only [2][0][3][zzz]
[1][2]
Only the Red led will operate. This option is highly recommended to avoid the
possibility that the intruder will “Learn” the detector behavior.
3 LEDS [2][0][3][zzz]
[1][3]
All 3 LEDs will operate.
PIR Sensitivity Normal [2][0][3][zzz]
[2]
Defines the sensitivity of the detector(MW + PIR)
Sensitivity Options [2][0][3][zzz]
[2][1]..[4]
1) Low
2) Medium
3) Normal
4) High
MW Range Trimmer [2][0][3][zzz]
[3]
Defines the microwave channel range. The maximum is 23m.
16 WatchOUT DT Installation Manual
Quick Keys Parameter Default
MW Range options [2][0][3][zzz]
[3][1]..[7]
1) Minimum
2) 20%
3) 40%
4) 60%
5) 80%
6) Maximum
7) Trimmer (MW is defined
by the trimmer setting on
the PCB)
Alarm Logic PIR and Microwave
[2][0][3][zzz]
[4]
Determine the detector’s logic of defining an alarm.
PIR and Microwave
[2][0][3][zzz]
[4][1]
Alarm is activated when both PIR and MW channels detect an alarm
(AND Logic)
PIR or Microwave
[2][0][3][zzz]
[4][2]
An alarm is activated when either PIR or MW channels detect an alarm (OR
Logic)
Lens Type Wide Angle
[2][0][3][zzz]
[5]
Defines the actual Lens of the detector
Lens Type Options
[2][0][3][zzz]
[5][1]..[2]
1) Wide Angle 2) Barrier / Long Range
Anti-Mask Enable
[2][0][3][zzz]
[6]
Defines the operation of Anti Masking detection
Anti-Mask Options
[2][0][3][zzz]
[6][1]..[2]
1) Disable 2) Enable (Default)
Arm/Disarm No
[2][0][3][zzz]
[7]
Defines the operation of the LEDs anti masking detections while the detector
is armed
No
[2][0][3][zzz]
[7][1]
AM (Anti masking) is enabled
LEDs behave according to the LEDs parameter definition
Yes
[2][0][3][zzz]
[7][2]
AM (anti masking) is disabled
LEDs are disabled
System Parameters
System: System Control
Quick Keys Parameter Default:
AM=Tamper No [1][2][36]
Used to determine the operation of Anti Masking detection
Yes: Anti mask violation will activate tamper alarm.
No: Anti mask violation will be regarded as trouble event.
VBR=Tamper No [1][2][37]
Used to determine the operation of the vibration detection (applicable to
versions with Vibration sensor installed)
Yes: Vibration detection will activate tamper alarm.
No: Vibration detection will be regarded as trouble event.
WatchOUT DT Installation Manual 17
English
Diagnostics
The ProSYS enables you to test parameters that reflect the operation of the detector.
1. From the main user menu press
[4] to access the Maintenance menu.
2. Enter the Installer code (or sub-installer) and press
/ .
3. Press [9] [1] to for the BUS Zones diagnostic menu.
4. Enter the digit of the zone that you want to test and then press
/ . The system will
perform the diagnostics test and a list of test parameters will appear, as indicated in the table
below.
5. Use the keys
/ / to view the diagnostics test results.
User Menu: 4) Maintenance 9) Diagnostic 1) BUS Zone
Quick Keys Parameter
[4][9][1][zzz]
Detector Input Voltage: Display the input voltage of the detector.
PIR 1 Level: PIR channel 1 DC level. Range 0.1v - 4v
PIR 1 Noise Level: PIR channel 1 AC level. Range 0VAC (No noise) - 4VA
PIR 2 Level: PIR channel 2 DC level. Range 0.1v - 4v
PIR 2 Noise Level: PIR channel 2 AC level. Range 0VAC (No noise) - 4VA
MW 1 Level: MW channel 1 DC level Range 0.1v - 4v
MW 1 Noise Level
: MW channel 1 AC level (0VAC (No noise) - 4VAC)
MW 2 Level: MW channel 2 DC level Range 0.1v - 4v
MW 2 Noise Level: MW channel 2 AC level (0VAC (No noise) - 4VAC
18 WatchOUT DT Installation Manual
Manuale di installazione WatchOUT DT 19
Italiano
Indice Dei Contenuti
Installazione in modalità relé ................................................................................................. 20
Introduzione....................................................................................................................... 20
Installazione....................................................................................................................... 20
Considerazioni per l’installazione ......................................................................................... 20
Installazione a parete............................................................................................................ 21
Installazione piana................................................................................................................ 21
Installazione angolare di 45° (installazione a sinistra).......................................................... 21
Modifica della posizione del tamper antirimozione............................................................... 22
Cablaggio morsettiera.................................................................................................. 22
Predisposizione Microinterruttori ............................................................................ 23
Regolazione microonda ............................................................................................... 23
Prova di movimento ........................................................................................................... 23
Indicatori LED .................................................................................................................... 23
Ponticello Modalità Relé / BUS ................................................................................. 24
Installazione dello snodo standard........................................................................ 24
Installazione a parete............................................................................................................ 24
Installazione per tubo elettrico.............................................................................................. 24
Sostituzione delle Lenti................................................................................................. 27
Tipologie di Lenti................................................................................................................... 28
Caratteristiche Tecniche............................................................................................... 29
Informazioni per l’ordine ............................................................................................ 29
Installazione in modalità BUS ................................................................................................ 30
Introduzione....................................................................................................................... 30
Cablaggio morsettiera.................................................................................................. 30
Tamper Antiapertura e Antirimozione .............................................................................. 30
Solo Tamper Antiapertura................................................................................................ 30
Tamper Antiapertura ad un Ingresso di Zona .................................................................. 30
Predisposizione microinterruttori ............................................................................ 30
Programmazione ProSYS............................................................................................. 31
Aggiunta e Cancellazione del WatchOUT DT ...................................................................... 31
Configurazione dei parametri del WatchOUT DT................................................................. 32
Parametri di Sistema...................................................................................................... 33
20 Manuale di installazione WatchOUT DT
Installazione in modalità relé
Introduzione
Il rivelatore da esterno Doppia Tecnologia WatchOUT di RISCO Group è un dispositivo a
microprocessore che elabora i segnali rilevati tramite due canali all’infrarosso passivo (PIR) e due
canali a microonda (MW). Il rivelatore può funzionare come rivelatore tradizionale con uscite a
relé collegabili a qualsiasi centrale d’allarme, o come rivelatore indirizzato via BUS 485 collegato
ai sistemi ProSYS di RISCO. Quando viene collegato ai sistemi ProSYS, il rivelatore può essere
programmato e testato sia localmente che in remoto tramite tastiere LCD ProSYS e/o software di
Teleassistenza RISCO. Le istruzioni che seguono descrivono l’installazione e la configurazione
del WatchOUT sia in modalità Relé che via BUS. Per informazioni sul collegamento in modalità
BUS ProSYS, consultare il capitolo “
Installazione in modalità BUS”.
Installazione
Considerazioni per l’installazione
If Se possibile, evitare di direzionare l’unità
verso oggetti in movimento (alberi ondeggianti,
cespugli, ecc.)
1m - 2.7m
(3'3" - 8'9")
Altez installate: Grandangolo 15m 90°
(RL300)
Note:
1. Per altezze di installazione basse, al di sotto di
1.7m ove è richiesta l’opzione di
discriminazione animali, vanno utilizzate le lenti
RL300F (muri bassi o installazione su
recinzioni).
2. La discriminazione animali (altezza
dell’animale senza limiti di peso) arriva fino a
70 cm con il rivelatore installato a 2.2m. Se
l’altezza di installazione è al di sotto di 2.2
metri la discriminazione animali si riduce
proporzionalmente. Ogni 10cm in meno
rispetto a 2.2 metri corrispondeono 10 cm in
meno di altezza dell’animale discriminato.
Mantenere una distanza
di almeno 5m (16') da
oggetti in movimento
Fuori campo di
rilevazione
5m (16')
Assicurarsi che nessun oggetto ostruisca il
campo di rilevazione dell’unità sia per la
sezione a microonda sia per quella ad
infrarossi. Prestare attenzione alla crescita di
alberi, rami e ad eventuali altre piante che con
il tempo possono coprire l’area di rilevazione.
Per quelle installazioni vicino a strade ad intenso traffico di
veicoli o oggetti oltre l’area di rilevazione desiderata, si
consiglia di regolare la sensibilità della microonda (MW) e/o
inclinare il rivelatore verso il basso.
Nota:
Inclinando il rivelatore verso il basso è possibile che la funzione di
immunità agli animali si riduca.
Per una migliore rivelazione
selezionare una posizione di
installazione in modo che
l’eventuale intruso attraversi
l’area di copertura del rivelatore
con una traiettoria di circa 45°
rispetto allo stesso.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88

Risco WatchOUT Guide d'installation

Taper
Guide d'installation