Best IP29M42SB Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation

Ce manuel convient également à

IP29M SERIES
HB0063
INSTALLATION INSTRUCTIONS
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE AND OPERATION INFORMATION
ON PAGES 13 TO 16.
READ AND SAVE THESE INSTRUCTIONS
BEST; Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711
BEST; Drummondville, QC, Canada www.BestRangeHoods.com 866-737-7770
To register your product online or for additional information visit www.BestRangeHoods.com
SV08072 rev. 14
! !
2
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA) and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. When applicable local regulations comprise more
restrictive installation and/or certification requirements,
the aforementioned requirements prevail on those of this
document and the installer agrees to conform to these at his
own expenses.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn power pack ON when cooking at high heat or
when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Your range hood motor has a thermal overload which will
automatically shut off the motor if it becomes overheated. The
motor will restart when it cools down. If the motor continues to
shut off and restart, have the range hood serviced.
5. For best capture of cooking impurities, the bottom of the hood
should be at a minimum of 30” and at a maximum of 36” above
the cooking surface.
6. Two installers are recommended because of the large size and
weight of this unit.
7. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside — Do not exhaust air into spaces within walls
or ceiling or into attics, crawl space or garage.
8. This product is equipped with a thermostat which may start
blower automatically. To reduce the risk of injury and to prevent
power from being switched on accidentally, switch power off at
service panel and lock or tag service panel.
9. Because of the high exhausting capacity of this hood, you
should make sure enough air is entering the house. Use an
appropriate make-up air device or open a window close to or
in the kitchen.
10. To reduce the risk of fire and electrical shock, the Best IP29M
Series hood must be installed with Best interior blower models
iQ6, P3, P6, iQ12 or P12; Best exterior blower models EB6,
EB9, EB12 or EB15; Best in-line blowers models ILB3, ILB6,
ILB9, ILB11. Other blowers cannot be substituted. (Blowers
sold separately.)
11. Please read specification label on product for further
information and requirements.
WARNING
!
CAUTION
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels —
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to
operate it.
B. The fire is small and contained in the area where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
WARNING
!
3
HL0172
- IP29M SERIES RANGE HOOD SYSTEMS -
INTERIOR BLOWERS
MODEL 441
(10” ROUND WALL CAP)
MODEL 643
(8” R
OUND WALL CAP)
M
ODEL 421
(10” ROUND VERTICAL IN-LINE
DAMPER, INCLUDED WITH
IQ12 AND P12
BLOWER/ROUGH-IN KITS)
M
ODEL 437
(HIGH CAPACITY ROOF CAP)
8” R
OUND ADAPTER/DAMPER
(INCLUDED WITH IQ6, P3 AND P6
BLOWER/ROUGH-IN KITS)
8” ROUND
STANDARD
DUCT
8” ROUND
ADJUSTABLE ELBOW,
OPTIONAL
MODEL 634 OR 644
(R
OOF CAP)
M
ODEL 418
(10” ROUND
ADJUSTABLE ELBOW,
OPTIONAL)
M
ODEL 410
(10” ROUND DUCT
2 FT. SECTIONS)
OPTIONAL
DECORATIVE FLUE
AEIP SERIES
OPTIONAL
DRY WALL TRIM
ATDIP SERIES
IP29M SERIES HOOD
(C
ANOPY WITH
BLOWER CONTROLS & LIGHTING.
REQUIRED FOR ALL INSTALLATIONS)
MODEL iQ12 OR P12
BLOWER/ROUGH-IN KIT
(1200
CFM INTERIOR BLOWER &
ROUGH-IN PLATE)
MODEL iQ6, P3 OR P6
BLOWER/ROUGH-IN KIT
(600 CFM (EXCEPT 300 CFM
FOR P3) INTERIOR BLOWER
& ROUGH-IN PLATE)
4
HL0090
- IP29M SERIES RANGE HOOD SYSTEMS -
IN-LINE AND EXTERIOR BLOWERS
MODEL 441
(10” ROUND WALL CAP)
M
ODEL 643
(8” ROUND
WALL CAP)
M
ODEL 421
(10” ROUND VERTICAL
IN-LINE DAMPER)
RECOMMENDED FOR USE
WITH EXTERIOR BLOWERS.
MODEL 437
(HIGH CAPACITY ROOF CAP)
M
ODEL 418
(10” ROUND
ADJUSTABLE ELBOW,
OPTIONAL)
M
ODEL 410
(10” ROUND DUCT
2 FT. SECTIONS)
OPTIONAL
DECORATIVE FLUE
AEIP SERIES
OPTIONAL
DRY WALL TRIM
ATDIP SERIES
IP29M SERIES HOOD
(C
ANOPY WITH
BLOWER CONTROLS & LIGHTING.
REQUIRED FOR ALL INSTALLATIONS)
M
ODEL 441
(10” ROUND
WALL
CAP)
M
ODEL ILB9 (800 CFM)
OR ILB11 (1100 CFM)
IN-LINE BLOWER
(INCLUDES TWO 8” X 12TO
10
ROUND TRANSITIONS)
MODEL ILB6 (600 CFM)
IN-LINE BLOWER
(INCLUDES TWO 4½” X 18½”
TO 10ROUND TRANSITIONS)
M
ODEL ILB3 (280 CFM)
IN-LINE BLOWER
(INCLUDES ONE 8” TO 10
ROUND TRANSITION)
M
ODEL EB6 (600 CFM)
OR EB9 (900 CFM)
EXTERIOR BLOWER
MODEL EB12 (1200 CFM)
OR EB15 (1500 CFM)
EXTERIOR BLOWER
IN-LINE AND EXTERIOR
BLOWER ROUGH-IN KIT
(INCLUDED WITH EB6, EB9,
EB12, EB15, ILB3, ILB6,
ILB9 AND ILB11 BLOWERS)
5
1. SELECT BLOWER OPTION AND INSTALLATION TYPE
Either an interior or an exterior blower or in-line blower may be used with this hood. The Best IP29M Series must be installed with blower
models iQ6, P3, P6, iQ12, P12, ILB3, ILB6, ILB9, ILB11, EB6, EB9, EB12 or EB15 only. Other blowers cannot be substituted. (Blowers
sold separately.)
Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 9, 11 to 15, 18 and up of this
manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. Use metal duct tape to seal duct joints.
NOTE: It is recommended that there be a minimum of 6” of straight duct from this hood to an elbow for 8” ducting and 12” for 10” ducting.
8” (203) ROUND DUCT
ROOF CAP
30” TO 36” (762 to 914)
ABOVE COOKING SURFACE
HOOD
DECORATIVE
FLUE
12”, 18”, 24” or 30”
(305, 457, 610 or 762)
or TRIM
HH0165A
NOTE: Dimensions in ( ) are in mm.
10” (254) ROUND DUCT
ROOF CAP
30” TO 36” (762 to 914)
ABOVE COOKING SURFACE
HOOD
DECORATIVE
FLUE
12”, 18”, 24” or 30”
(305, 457, 610 or 762)
or TRIM
HH0166A
NOTE: Dimensions in ( ) are in mm.
MODEL iQ6, P3 OR P6
SINGLE INTERIOR BLOWER
TYPICAL DUCTWORK
MODEL iQ12 OR P12
DUAL INTERIOR BLOWER
TYPICAL DUCTWORK
10” (254)
ROUND DUCT
EXTERIOR
BLOWER
30” TO 36” (762 to 914)
ABOVE COOKING SURFACE
HOOD
DECORATIVE
FLUE
12”, 18”, 24” or 30”
(305, 457, 610 or 762)
or TRIM
HH0082A
NOTE: Dimensions in ( ) are in mm
IN-LINE BLOWER
HH0083A
30” TO 36” [762 to 914]
ABOVE COOKING SURFACE
ROOF CAP
WALL
CAP
HOOD
NOTE: Dimensions in [ ] are in mm.
DECORATIVE
FLUE
12”, 18”, 24” or 30”
[305, 457, 610 or 762]
or TRIM
10” [254] ROUND DUCT
(except ILB3, 8’’ [203] ROUND DUCT)
MODEL EB6, EB9, EB12 OR EB15
EXTERIOR BLOWER
TYPICAL DUCTWORK
MODEL ILB3, ILB6, ILB9 OR ILB11
IN-LINE BLOWER
TYPICAL DUCTWORK
6
2. MEASURE INSTALLATION
Dimensions for the most common installation are shown at right.
The minimum hood distance above cooktop must not be less than 30’. A maximum of 36”
above cooktop is highly recommended for best capture of cooking impurities.
Distances over 36” are at the installer and users discretion.
Since framework must be flush to ceiling, 4 decorative flue covers have been created to fit both
hood widths and different ceiling heights. Refer to table below to choose the model that fits your
needs.
DECORATIVE FLUE COVER
8’ CEILING
DISTANCE
FROM COOKTOP
9’ CEILING
DISTANCE
FROM COOKTOP
MODEL A (HEIGHT)WIDTH 30” 36” 30” 36”
AEIP422 12” 42” X
AEIP542 12” 54” X
AEIP428 18” 42” X
AEIP548 18” 54” X
AEIP424 24” 42” X
AEIP544 24” 54” X
AEIP420 30” 42” X
AEIP540 30” 54” X
NOTE: For ceilings over 9’, decorative flues are not available.
If a drywall box will be built instead of installing decorative flue cover, use drywall trim to hide hood and drywall junction. Refer to table
below to find the appropriate model for your hood width.
3. PREPARE THE INSTALLATION
NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer.
Remove the installation kit from inside the hood.
Make sure that the following items are included:
- Installation manual
- Accessories including:
• Hybrid baffle filters with handles (3 for 42” width hood, 5 for 54” width hood)
• Shielded halogen bulbs (GU10 type base, 120 V, 50 W) (6 for 42” width hood, 8 for 54” width hood)
• Bag of parts including:
(10) steel wood screws no. 10 x 1.5’, (10) steel washer no. 10, (6) screws no. 8 x 3/8’ (additional screws provided)
Parts sold separately:
- Interior blower model iQ6, P3 or P6 (includes rough-in plate and 8” round adapter and damper).
- Interior blower model iQ12 or P12 (includes rough-in plate and 10” round vertical in-line damper, model 421).
- In-line blower assembly model ILB3, ILB6, ILB9 or ILB11 (all include transition(s) and rough-in plate)
- Exterior blower assembly model EB6, EB9, EB12 or EB15 (all include rough-in plate).
- Duct, elbows, dampers, wall and roof caps. Refer to pages 3 and 4 for a complete list of venting options and model numbers.
- Optional decorative flue cover AEIP Series, 12’, 18”, 24” or 30” height and 42” or 54” width.
- Optional dry wall trim ATDIP Series, 42” or 54” width.
LINKLOGIC® ENABLED HOOD
This hood includes the LinkLogic system which allows communication over ordinary household electrical wiring to other LinkLogic devices
including the Broan Smart Sense Fan system. If you intend to use this hood with another LinkLogic device, follow the instructions found in
Section 21 along with the instructions that come with the LinkLogic device you plan to use.
WARNING
!
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
HH0084A
A
Framework
flush to ceiling
Standard 36”
(914 mm)
high cooktop
Minimum distance between
the hood and cooktop:
30’ (762 mm)
Recommended maximum
distance between the hood
and cooktop: 36’ (914 mm)
Decorative flue
cover or drywall
with trim
MINIMUM AND MAXIMUM DISTANCE
OVER COOKTOP
MODEL WIDTH
ATDIP42
ATDIP54
42”
54”
7
4. PREPARE THE BLOWER HOUSING
Detach the blower housing from the hood by removing both retaining screws (A).
Keep the screws for further use.
Fold up both flanges (B). The flanges must be perpendicular to the top of the
blower housing.
5. REMOVE THE FILTERS AND THE GREASE DRIP RAIL
A. Remove tape on filters. Remove filters from hood and
set aside.
NOTE: It is recommended to start with the center one.
B. Remove tape on grease drip rail (1).
Lift out grease drip rail and set aside.
6. REMOVE THE PAN
NOTE: Do not remove the 4 screws located on the
notched parts of the pan (A on figure below).
HD0238
B
HD0229
B
A
HD0222
1
HD0223
A
A
HD0224
RETAINING SCREWS LOCATION
Using a Phillips no. 2, remove 8 screws
retaining the pan (shaded part on
illustration at right) to the hood.
Remove the pan and set aside.
8
7. BUILD THE FRAMEWORK
The framework must be sized to support the total weight of the hood. Refer to the table below for total weight of the hood, according to
the type of blower chosen.
In the ceiling material, cut-out a 28¾” x 12½” max.
opening over the installation location. Install two
supporting studs inside the cut-out at dimensions
shown at right.
WARNING
!
When building framework, always follow all applicable construction codes and standards.
HOOD WIDTH
WITH IQ6, P3 OR P6
INTERIOR BLOWER
WITH IQ12 OR P12
INTERIOR BLOWER
WITH IN-LINE OR EXTERIOR BLOWER
(ROUGH-IN PLATE ONLY)
42” 71
LB. 84 LB. 52 LB.
54” 86
LB. 99 LB. 67 LB.
7.1 SUGGESTED FRAMEWORK FOR INSTALLATION WITH DECORATIVE FLUE COVER AEIP SERIES
28½”
12½”
max.
27”
C
L
28¾”
HD0227A
C
L
12 /
8
5
Studs flush
with ceiling material
Ceiling
material
Ceiling
material
SUPPORTING STUDS
Using provided wood screws no. 10 x 1.5” and washers, assemble both mounting brackets
(included with the optional decorative flue cover) to the framework. See illustration at right.
HD0228A
7.2 SUGGESTED FRAMEWORK FOR INSTALLATION WITH DRYWALL TRIM ATDIP SERIES
Below is the suggested framework for both 42” and 54” width hoods to be installed with drywall trim ATDIP Series. Refer to the table
and illustrations below for the dimensions according to the hood width. Using provided wood screws no. 10 x 1.5” and washers,
assemble both mounting brackets (included with the optional drywall trim) to the framework.
HOOD WIDTH A WITH 5/8” DRYWALL A WITH 1/2” DRYWALL B WITH 5/8” DRYWALL B WITH 1/2” DRYWALL C
42” 11
5
/8”11
7
/8 28
5
/8 28
7
/8 10” MINIMUM
54” 11
5
/8”11
7
/8 40
5
/8 40
7
/8 10” MINIMUM
HD0235A
FRAMEWORK 42” HOOD
27¼”
C
C
L
C
L
HD0237A
FRAMEWORK 54” HOOD
FRAMEWORK
TOP VIEW
9
8. INSTALL BLOWER HOUSING
Use both screws (A) previously removed in step 4 to assemble the blower housing to the mounting brackets. For installation with decorative
flue cover AEIP Series only, place 4 nuts (B) (from flue cover parts bag) on the pem studs, leaving 1/4” for the hood installation. The blower
housing must be installed in such a way that its label (C) will be on the same side as the hood control side. See illustrations below.
HD0230
INSTALLATION WITH DECORATIVE FLUE COVER AEIP SERIES
HD0231
INSTALLATION WITH DRYWALL TRIM ATDIP SERIES
A
A
B
B
C
C
9. SECURE BLOWER HOUSING TO BRACKETS
From the inside, secure the blower housing to mounting brackets, using 2 no. 8 x 3/8” screws
per side.
Screws must be installed in embossed sections, see details at right.
HO0100
RETAINING SCREWS LOCATION
10. INSTALL 8” ROUND ADAPTER AND DAMPER TO ROUGH-IN PLATE
(iQ6, P3 OR P6 INTERIOR BLOWERS ONLY)
Attach transition to iQ6, P3 or P6 blower rough-in plate.
Use metal duct tape to make all joints secure and air-tight.
HO0196
11. INSTALL THE ROUGH-IN PLATE IN THE BLOWER HOUSING
Run power cable to installation location. Refer to the instructions included with
the selected blower/rough-in kit (sold separately) for details on installing the
rough-in plate. Install the rough-in plate so that the wiring box is located on the
right side when facing the hood, as specified on the blower housing label.
Connect adapter/damper or rough-in plate (according to blower model) to
ductwork. Use metal duct tape to make all joints secure and air-tight.
HD0232
WIRING COVER
LOCK NUTS
10
12. CONNECT THE WIRING
13. FINISH THE DRYWALL BOX (INSTALLATION WITH DRYWALL TRIM ATDIP SERIES ONLY)
WARNING
!
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable
codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting
means to prevent power from being switched on accidentally.
Remove wiring cover from rough-in plate and set aside.
Connect wires as follow: BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw. DO NOT FORGET
TO CONNECT THE GROUND. Reinstall wiring cover.
Finish the drywall box. Check fitting with dry wall trim before mounting it to the hood.
14. MOUNT THE DECORATIVE FLUE COVER OR THE DRYWALL TRIM ON THE HOOD
WARNING
!
The decorative flue cover AEIP Series and the drywall trim ATDIP Series may have sharp edges. Be careful when
handling and installing these metal parts.
MOUNTING SCREWS LOCATION
HD0233
14.1 INSTALLATION WITH DECORATIVE FLUE COVER AEIP SERIES
Remove the protective plastic film covering the decorative flue
cover AEIP Series. Assemble the flue cover on top of hood using
(14) no. 8 x 3/8” screws (provided with decorative flue cover). See
illustration at right to locate mounting screws from top of hood.
NOTE: Ensure edges fit perfectly before tightening completely the
mounting screws.
14.2 INSTALLATION WITH DRYWALL TRIM ATDIP SERIES
Remove the protective plastic film covering the drywall trim ATDPI
Series. Assemble the drywall trim on the top of the hood using
(14) no. 8 x 3/8” screws (provided with drywall trim). See illustration
at right to locate mounting screws from top of hood.
NOTE: Ensure edges fit perfectly before tightening completely the
mounting screws.
15. INSTALL THE HOOD
15.1 INSTALLATION WITH DECORATIVE FLUE COVER AEIP SERIES
Assemble the hood assembly to the mounting brackets by aligning keyholes with
4 nuts previously installed in step 8 (2 nuts per side). While holding the hood, remove
one nut and install a washer (included in parts bag) on each pem stud, then reinstall
the nut and tighten it. See illustration at right.
15.2 INSTALLATION WITH DRYWALL TRIM ATDIP SERIES
Align hood keyholes with pem studs on brackets. Secure the hood to the brackets
using washers and nuts (included in parts bag). See illustration at right.
HD0234
11
16. INSTALL THE BLOWER (INTERIOR OR EXTERIOR BLOWER)
Refer to instructions included with blower.
Once the blower is installed, plug the blower cord (A) into the female receptacle
and the power supply cord (B) onto the male connector inside the hood.
18. REINSTALL THE PAN
HE0078
AB
WARNING
!
Do not plug the two cords into each other.
CAUTION
Remove protective plastic film covering pan sides and tape over halogen lamps.
HD0224
RETAINING SCREWS LOCATION
Using a Phillips no. 2 or Robertson no. 2 screwdriver and the retaining screws, reinstall the pan
(previously removed in step 6) inside the hood (shaded part on illustration at right).
17. INSTALL THE CALIBRATION BUTTON BRACKET IN THE HOOD
(iQ6 AND iQ12 INTERIOR BLOWERS ONLY)
Both iQ6 and iQ12 blowers are equipped with a calibration button
already mounted to its own bracket. Install this bracket in the hood, using
2 screws provided with iQ6 or iQ12 interior blower.
HD0540
12
19. REINSTALL GREASE DRIP RAIL AND BAFFLE FILTERS
Reinstall grease drip rail (1). The illustration at right shows how to reinsert the
grease drip rail(s) into the range hood.
HD0225
1
CAUTION
Remove protective plastic film covering hybrid baffle filters before installing them.
12
HD0226
Reinstall hybrid baffle filters on the hood.
It is recommended to install side filters first
and finish with center one.
1. Insert one end of hybrid baffle filter into
the front channel of the hood.
2. Raise the other end toward the inside of
hood and insert in the grease drip rail of
the hood.
Replacement filters are available from your
dealer. See label inside hood for size and
part number.
13
20. LIGHT BULBS REPLACEMENT
This hood requires shielded halogen lamps (120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base), included.
NOTE: Before using lamps, remove shipping tape on them (if present).
1. To remove lamps, gently push upwards and turn counterclockwise to
disengage bulb leads from their grooves.
NOTE: If need be, use a rubber dishwashing glove to add grip when
removing the bulb.
2. Install the new lamps by placing the bulb leads into their grooves in
the socket.
3. Gently push upwards and turn clockwise until secure.
NOTE: If need be, use a rubber dishwashing glove to add grip when
removing the bulb; or use suction cup tool available from Best
to ease removal of the bulbs. Contact Best Technical Support at
1-800-558-1711 to order suction cup tool, part number 99526707.
WARNING
!
Do not touch lamps during or soon after operation. Burns may occur. In order to prevent the risk of personal injury,
only install shielded halogen lamps. Also, never install a cool beam, a dichroic lamp, a lamp not suitable for use in
recessed luminaires or identified for use in enclosed fixtures.
12 3
HO0089
21. USE AND CARE
Hybrid Baffle Filters
The hybrid baffle filters should be cleaned frequently. Use a warm detergent solution. Wash more often if your cooking style generates
greater grease—like frying foods or wok cooking.
Remove hybrid baffle filters by pushing them towards the back of hood and rotating filters downward. Baffle filters are dishwasher safe.
Allow filters to dry completely before reinstalling them in the hood.
Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate detergent
or as a result of local water conditions — but this will not affect filter performance. This discoloration is not covered by the warranty.
Grease Drip Rail
The grease drip rail should be cleaned frequently. Lift it out from the hood and use a warm detergent solution. As for the baffle filters, wash
more often if your cooking style generates greater grease—like frying foods or wok cooking. Allow grease drip rail to dry completely before
reinstalling it in the hood.
Blower Cleaning
Remove the filters in order to access the blower. Vacuum blower to clean. Do not immerse in water. Refer to blower instruction manual for
more details.
Hood cleaning
Stainless steel cleaning: How to maintain its “BRIGHT LOOK”
Avoid when choosing a detergent:
- Any cleaners that contain bleach will attack stainless steel.
- Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should never be
used close to a range.
Do:
Regularly wash with clean cloth or rag soaked with warm water
and mild soap or liquid dish detergent.
Always clean in the direction of original polish lines.
Always rinse well with clear water (2 or 3 times) after cleaning.
Wipe dry completely.
You may also use a specialized household stainless steel
cleaner.
Don’t:
Use any steel or stainless steel wool or any other scrapers to
remove stubborn dirt.
Use any harsh or abrasive cleansers.
Allow dirt to accumulate.
Let plaster dust or any other construction residues reach the
power pack. During construction/renovation, cover the power
pack to make sure no dust sticks to stainless steel surface.
14
22. OPERATION
Always turn ON your hood before you begin cooking in order to establish an air flow in the kitchen. Let the blower run for a few minutes to
clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
Cooktop Lighting (Halogen)
The halogen lighting is controlled by the light push-button (item 1 on illustration above). Push once to turn ON the lights, and push a second
time to turn the lights ON to a brighter level. If the lights are at the highest level, pressing another time will set them to the lowest intensity.
Press on the push-button and maintain for 1 second to turn Off the lights and set the memorized intensity. When turned on, the halogen
bulbs will light cooktop at the previous setting.
Use 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (included).
Blower
The blower is controlled by the blower push-button (item 2 on illustration above). Push once to turn ON the blower, and push a second
time to set the blower speed to a higher level. If the blower speed is on maximum level, pressing another time will turn the blower to the
lowest speed.
When power level 1 is activated from OFF, 100% of power level is activated during 0.3 second acting as a “kick-start”.
Press on the push-button and maintain for 1 second to turn Off the blower and set the memorized speed. When turned ON, the blower
will operate at the previous setting.
When the blower is ON, the speed level is shown by the center icon (item 8 on illustration above) while the icon 10 appears (the speed
of the rotational movement is proportional to the blower speed).
When the blower is on the higher speed, the icon 10 shuts off and the icon 6 appears with “max” (the symbol has a rotational movement).
Functions
Pressing on Enable/Disable functions push-button (item 3 on illustration above) allows to control Particulate Sensor and Air Refresh hood
functions.
Particulates Sensor
To activate the particulate sensor function, press on Enable/Disable functions push-button (item 3 on illustration above), the particulates
sensor icon (item 7 on illustration above) will appear.
When the sensor is activated, the blower turns ON automatically when some particulates, vapors or smokes caused by cooking
process, or abnormal gas emissions in the environment are detected. The blower speed is automatically set depending on the
particulates amount and the sensibility settings of the particulates sensor. See next paragraph.
To stop the particulates sensor function, press on Enable/Disable functions push-button until particulates sensor icon turns off.
Particulates sensor sensibility settings
• Press on Enable/Disable functions push-button (item 3 on illustration above) to activate the particulate sensor function, this will light up
the particulates sensor icon (item 7 on illustration above). Then, press and maintain for 2 seconds the Enable/Disable functions push-button:
the sensor sensivity level will appear on center icon (item 8 on illustration above).
Press again on this push-button to change the sensor sensitivity level (from 0 [minimum sensitivity] up to 9 [maximum sensitivity]).
Press on the grease filter reset push button (item 4 on the illustration above) to confirm (or is confirmed automatically after 5 seconds).
Air Refresh
To activate the air refresh function, press on Enable/Disable functions push-button (item 3 on illustration above), the air refresh
function icon (item 9 on illustration above) will appear.
To stop the air refresh function, press on Enable/Disable functions push-button until air refresh icon turns off.
Air refresh function activates only when blower is OFF. When activated, the blower hood recycles the air in the environment in perfect
silence, starting every 50 minutes (for 10 minutes, on first speed).
Grease filter reset
Once the grease filter cleaning is done, press on the grease filter reset push-button (item 4 on control illustration) to reset the filter
maintenance timer. This will also shut off the grease filter maintenance icon (item 5 on control illustration).
max
S
E
N
S
O
R
AIR
REFRESH
HC0032
12 5 67 8 910 11 34
1. Halogen light push button/
LinkLogic® Master Link Mode push button
2. Blower push button
3. Enable/Disable functions push button/
LinkLogic® Erase Link push button
4. Grease filter reset push button/
LinkLogic® Link Mode push button
5. Grease filters maintenance icon
6. Maximum blower speed icon
7. Particulates sensor icon
8. Blower speed level/
LinkLogic® state icon
9. Air refresh fuction icon
10. Blower speed icon
11. LinkLogic® icon
15
23. OPERATION (CONT'D)
Grease filter maintenance indicator
After 30 hours of operation, the grease filter maintenance icon (item 5 on control illustration) appears. This means filters need to be
cleaned.
Once the grease filter cleaning is done, press on grease filter reset push-button to reset the filter maintenance timer.
Interface backlighting
Off mode (Blower off, Particulates sensor and Air refresh modes disabled): Backlighting is off.
Halogen lighting activated: does not affect backlighting.
Blower turns on: Backlighting at maximum intensity.
Particulates sensor and Air refresh mode activated: Backlighting at maximum intensity.
Particulates sensor at sensitivity settings and Air refresh in activated mode: Backlighting at minimum intensity.
HEAT SENTRY™
This hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will start or speed up the blower if it senses
excessive heat above the cooking surface.
If blower is OFF—it turns the blower to speed 3 (blower speed icon shows H).
If blower is ON—it turns the blower up to speed 3 (blower speed icon shows H).
NOTE: When Heat Sentry™ is activated, Air refresh mode and Particulate sensor are inactivated. Also, communication coming from
the LinkLogic® Module is disabled.
• When the temperature level drops to normal, the blower will return to its original setting (blower speed icon will show the original
blower speed).
To turn off the blower when Heat Sentry™ is activated, press and hold the blower push-button (item 2 on illustration) for more than
1 second.
LinkLogic® Network compatibility
Your IP29M Series range hood can be linked to LinkLogic network, if installed in your house.
LINKLOGIC LINKING INSTRUCTIONS
A. ACTIVATE THELINKMODE OF THE HOOD
Push the LinkLogic link mode push-button (item 4 on control illustration) for 2 seconds; the LinkLogic icon of the interface (item 11 on
control illustration) should be visible and backlighting is full intensity at that point.
WARNING
!
The HEAT SENTRY can start the blower during a range top  re or other excessive heat situations even if the hood is turned off. In this
case, it is impossible to turn the blower OFF using control panel buttons. If you must stop the blower, unplug the blower power cord
(located behind the  lters) from the hood by pulling on its 2-prong connector; do not pull on the wire.
LINK FOR WALL REMOTE CONTROL, REMOTE CONTROL
OR
REMOTE BLOWER MODULES
LINK FOR SMARTSENSEOR MAKE-UP AIR MODULES
ACTIVATE THE “LINKMODE OF THE LINKLOGIC DEVICE
Push the “link” button of the LinkLogic device for
a specific duration to activate its link mode
(see instructions of LinkLogic device).
STA RT THE “A UTO-LINKPROCESS OF THE HOOD
Push the LinkLogic link mode push-button
(item 4 on illustration) to start the Auto-Link” process,
flashing “A should be visible (item 8 on control illustration)
on the interface until link is done.
NOTE: For some LinkLogic devices, no A” will be flashing
because the linking duration is too short.
GO TO STEP 22 (ON NEXT PAG E) TO CONFIGURE LINKLOGIC BOARD
JUMPERS BASED ON BLOWER PERFORMANCE.
STA RT THE “MASTER LINKPROCESS OF THE HOOD
Push the LinkLogic master link mode push-button
(item 1 on illustration) to start the “Master Link” process,
flashing “L should be visible (item 8 on control illustration)on
the hood interface, meaning that the hood is waiting for a
SmartSense™ or Make-Up Air module to link.
ACTIVATE THE “LINKMODE OF THE LINKLOGIC DEVICE
Push the “link” button of the LinkLogic device
(see instructions of device for location) for a specific duration to
activate its Link mode. Wait for the L to disappear from the
hood interface to do next step.
LINK OF ANOTHER LINKLOGIC DEVICE
Go back to the appropriate first step if another LinkLogic device
needs to be linked. Otherwise, to exit “link” mode, go to
E
XIT LINK MODE OF THE HOOD.
B. EXIT LINK MODE OF THE HOOD
Press and hold LinkLogic link mode push-button (item 4 on control illustration) for 2 seconds to exit “link” mode. Link mode remains
activated for 4 minutes if no other operation is done.
16
23. OPERATION (CONT'D)
ERASE LINK PROCESS
A. ACTIVATE THELINKMODE OF THE HOOD
Push the LinkLogic link mode push-button (item 4 on control illustration) for 2 seconds; the LinkLogic icon of the interface (item 11 on
control illustration) should be visible and backlighting is full intensity at that point.
B. ERASE ALL LINKED LINKLOGIC DEVICES
Push the LinkLogic erase link push-button (item 3 on control illustration) for 2 seconds to start the “Erase Link” process, flashing E
should be visible (item 8 on control illustration) on the hood interface until links are erased.
C. EXITLINKMODE OF THE HOOD
Press and hold LinkLogic link mode push-button (item 4 on control illustration) for 2 seconds to exit “link” mode. Link mode remains
activated for 4 minutes if no other operation is done.
NOTE: If during normal operation of the range hood, the LinkLogic Icon (item 11 on control illustration) starts blinking, an error occurred
while communicating with a linked LinkLogic device. To reset this error flag, customer needs to enter and exit the Linking mode
as explained previously. This will erase the error flag until it happens again. If the problem happens again, it is recommended to
erase all links and start back the whole linking process.
24. LINKLOGIC SYSTEM CONTROL BOARD JUMPERS
The LinkLogic system is designed to work with devices like the Broan Smart Sense Fan system that requires CFM output or this range
hood. If you are using this hood with a LinkLogic device that requires CFM information, please follow the simple instruction/matrix below to
configure the LinkLogic control board in the hood to provide the correct CFM information. To access the LinkLogic control board, remove
baffle filters, grease drip rail and hood pan (see steps 5 and 6). Remove both screws retaining the control panel to the hood. Rotate
carefully the control panel in order to see the LinkLogic board jumpers. Remove jumpers from current location on pins and reconfigure
based on blower performance.
HE0089
1
2
3
LINKLOGIC BOARD JUMPERS
Pin 1 Pin 2 Pin 3 Maximum CFM value
0 0 0 0 CFM
0 0 1 300 CFM
0 1 0 500 CFM
0 1 1 600 CFM
Pin 1 Pin 2 Pin 3 Maximum CFM value
1 0 0 900 CFM
1 0 1 1000 CFM
1 1 0 1200 CFM
1 1 1 1500 CFM
0 = No jumper on pin.
1 = Jumper on pin.
0 = No jumper on pin.
1 = Jumper on pin.
If you are unsure if the LinkLogic accessory or device requires CFM data, please refer to the unit’s instructions.
17
25. WIRING DIAGRAMS
INTERIOR BLOWER
B
W
W
B
W
B
W
B
M
MOTOR
INTERNAL BLOWER ASSEMBLY
NEUTRAL
LINE
GROUND
120 V SUPPLY
W
B
G
W
B
W
B
B
W
W
Y
H
EAT SENTRY
USER INTERFACE
321 321
J5 J6
COMMUNICATION
BOARD
(INSTEON)
P
ARTICULATES SENSOR
W
W
WW
W
WW W
Y
Y
YY
Y
Y
Y
Y
HE0183A
ROUGH-IN PLATE
COLOR CODE
B BLACK
G GREEN
W WHITE
Y YELLOW
LIGHT SOCKET LIGHT SOCKET LIGHT SOCKET LIGHT SOCKET
LIGHT SOCKET LIGHT SOCKET LIGHT SOCKET LIGHT SOCKET
18
25. WIRING DIAGRAMS (CONT'D)
IN-LINE OR EXTERIOR BLOWER
B
W
W
B
W
B
W
B
M
MOTOR
REMOTE BLOWER ASSEMBLY
NEUTRAL
LINE
GROUND
120 V SUPPLY
W
B
G
W
B
W
B
B
W
W
Y
H
EAT SENTRY
USER INTERFACE
321 321
J5 J6
COMMUNICATION
BOARD
(INSTEON)
P
ARTICULATES SENSOR
W
W
WW
W
WW W
Y
Y
YY
Y
Y
Y
Y
HE0184A
ROUGH-IN PLATE
COLOR CODE
B BLACK
G GREEN
W WHITE
Y YELLOW
GROUND
LIGHT SOCKET LIGHT SOCKET LIGHT SOCKET LIGHT SOCKET
LIGHT SOCKET LIGHT SOCKET LIGHT SOCKET LIGHT SOCKET
19
26. WARRANTY
WARRANTY
ONE-YEAR LIMITED WARRANTY FOR BEST PRODUCTS
Broan-NuTone LLC (Broan-NuTone) warrants to the original consumer purchaser of Best products that such products will be free from defects
in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be
defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS,
FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a)
normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance
or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states or provinces do not
allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S
SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE.
Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation
or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state or province to another. This
warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address stated below or telephone number stated below, (b) give the
model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service,
you must present evidence of the original purchase date.
In USA - Best
®
, 926 W. State Street, Hartford, WI 53027 (800-558-1711)
In Canada - Best
®
, 550 Lemire Blvd., Drummondville, QC, Canada, J2C 7W9 (866-737-7770)
www.BestRangeHoods.com
20
27. SERVICE PARTS
IP29M Series
HL0216
11
10
9
8
5
4
3
1
2
6
7
KEY NO.PART NO.DESCRIPTION
QTY. (HOOD WIDTH)
42” 54”
1 SV08069 CONTROL PROCESSOR UNIT 11
2 SV08073 PARTICULATES SENSOR 11
3 SV13924 MALE CONNECTOR 11
4 SV13923 FEMALE CONNECTOR 11
5 SV08074 C
ONTROL INTERFACE 11
6 SV05917 S
OCKET GU10 6 8
7 SV09435 SOCKET HOLDER GU10 6 8
8 SV09434 LIGHT TRIM STAINLESS STEEL 68
9 SV05921 S
HIELDED HALOGEN BULBS (50W, 120 V, PAR16, GU10) 6 8
10
SV61639 H
YBRID BAFFLE FILTER WITH MICROMESH AND HANDLE 8.84” X 8.61” X 1” 1 5
SV61640 HYBRID BAFFLE FILTER WITH MICROMESH AND HANDLE 11.84” X 8.61” X 1” 2 -
11
SV61934 GREASE DRIP RAIL FOR 42” HOOD 1-
SV61935 G
REASE DRIP RAIL FOR 54” HOOD -1
* SV03435
H
EAT SENTRY THERMISTOR
11
* SV08072 INSTALLATION GUIDE 11
* SV08068
PARTS BAG: STEEL WOOD SCREW NO. 10 X 1.5” (10),
SCREWS NO. 8 X 3/8” (6), STEEL WASHERS NO. 10 (10)
11
* SV05859 B
EST LOGO 11
* N
OT SHOWN.
KEY NO.PART NO.DESCRIPTION
QUANTITY
DECORATIVE FLUE DRYWALL TRIM
* SV06927
ACCESSORY PARTS BAG: STEEL HEXAGONAL LOCK-NUT (5),
SCREWS NO. 8 X 3/8” (14), STEEL WASHERS NO. 10 (10),
STEEL WOOD SCREW NO. 10 X 1.5” (10)
11
* N
OT SHOWN.
REPLACEMENT PARTS AND REPAIRS
In order to ensure your unit remains in
good working condition, you must use
Broan-NuTone genuine replacement
parts only. Broan-NuTone genuine
replacement parts are specially
designed for each unit and are
manufactured to comply with all the
applicable certification standards and
maintain a high standard of safety.
Any third party replacement part
used may cause serious damage and
drastically reduce the performance
level of your unit, which will result
in premature failing. Broan-NuTone
recommends to contact a certified
service depot for all replacement
parts and repairs.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Best IP29M42SB Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation
Ce manuel convient également à