Superior Fireplaces MHD40PFDMN Mode d'emploi

Catégorie
Cheminées
Taper
Mode d'emploi

Ce manuel convient également à

- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instruc-
tions.
If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d’entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
This appliance may be installed as an OEM installation in a manufactured home (USA only) or mobile home and
must be installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction
and Safety Standard, Title 24 CFR, Part 3280, in the United States, or the Standard for Installation in Mobile
Homes, CAN/CSA Z240 MH, in Canada. This appliance is only for use with the type(s) of gas indicated on the
rating plate. A conversion kit is supplied with the appliance.
Cet appareil peut être installé comme du matériel d’origine dans une maison préfabriquée (É.-U. seulement)
ou mobile et doit être installé selon les instruc! ons du fabricant et conformément à la norme Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280 aux États-Unis ou à la norme CAN/CSA Z240
Série MM, Maisons mobiles au Canada. Cet appareil doit être u! lisé uniquement avec les types de gaz indi-
qués sur la plaque signalé! que. Une trousse de conversion est fournie avec l’appareil.
Installation and Operation Instructions
Models
PFS
®
USC
Report No. 14-171
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900608-01.
P/N 900608-00 Rev. C 01/2019
MHD40STDMN
MHD40PFDMN
MHD40 Multi-View Series Direct-Vent Gas Fireplaces
P900608-00
2
General Information
900608-00, 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass is pro-
vided with this appliance and shall be installed for the protection of children and
other at-risk individuals.
DANGER
PELIGRO
VITRE CHAUDE
RISQUE DE BRÛLURES.
NE TOUCHEZ PAS UNE VITRE
NON REFROIDIE.
NE LAISSEZ JAMAIS UN ENFANT
DE TOUCHER LA VITRE.
EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
L’écran pare-étincelles fourni avec ce foyer réduit le risque de brûlure en cas de
contact accidentel avec la vitre chaude et doit être installé pour la protection Des
enfants et Des personnes à risques.
Vea el volante adjunto para la representación de color adecuado
See attached color flyer for proper color representation
Voir ci-joint tract pour une bonne représentation de la couleur
SAFETY AND YOUR FIREPLACE
Se provee con este aparato una barrera de protección (malla), diseñada para reducir
el riesgo de quemaduras por contacto accidental con el vidrio caliente que debe estar
instalada para protección de infantes y otros individuos en riesgo.
3
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
General Information
900608-00, 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
Afin d’éviter les brûlures
graves ou les blessures,
ne pas retirer l’écran de
protection de la foyer qui
empêche tout contact
direct avec la vitre.
Suivez les instructions de sécurité
ci-dessous et veillez à ce que tous
les membres de votre famille soient
conscients du danger de brûlure
encouru :
Les surfaces de votre foyer deviennent
EXTRÊMEMENT CHAUDES !
La vitre située à l'avant du foyer atteint
des températures EXTRÊMEMENT
ÉLEVÉES et peut causer de graves
blessures en cas de contact.
Tenez les enfants à l'écart du foyer
lorsqu'il fonctionne. Surveillez
attentivement les enfants dans les
pièces où un foyer est utilisé afin
d'éviter qu'ils ne soient en contact avec
la vitre.
Tenez tous les vêtements, les meubles,
l'essence et tout autre liquide
inflammable à l'écart du foyer.
Même après fermeture du gaz, les
surfaces du foyer restent extrêmement
chaudes.
Veillez à coller les Étiquettes de mise
en garde relatives à la sécurité
d'utilisation à l'endroit où vous
utilisez le foyer, pour rappeler à tous
les utilisateurs les dangers liés aux
températures élevées
(Page 35)
.
Lisez L’information de sûreté
importante (Pages 4-5)
.
Para evitar quemaduras y lesiones
graves, no quite el protector de malla
o guardia de seguridad que evita el
contacto directo con el vidrio.
Siga las instrucciones de seguridad
a continuación y asegúrese de que
todos en su hogar sepan acerca de este
peligro de quemadura:
¡Las superficies de la chimenea se
ponen MUY CALIENTES!
El vidrio delante de la
chimenea alcanza temperaturas
EXTREMADAMENTE ALTAS y puede
causar quemaduras graves si se toca.
Mantenga a los niños alejados de
la chimenea en funcionamiento.
Supervise en forma cercana a los niños
en cualquier cuarto donde haya una
chimenea funcionando para impedir el
contacto con el vidrio.
Mantenga la ropa, mobiliario, gasolina
y otros líquidos inflamables alejados
de la chimenea.
Aún después de haber apagado el
gas, las superficies de la chimenea
permanecen extremadamente
calientes.
Asegúrese de colocar las Etiquetas de
advertencia de seguridad de operación
en el lugar donde enciende la chimenea,
para que todos recuerden los peligros
asociados con las altas temperaturas
(Página 35)
.
Lea Información importante de
seguridad (Página 4-5).
Seguridad y su
chimenea
La sécurité et
votre foyer
[FRENCH][ENGLISH]
[SPANISH]
Safety and Your
Fireplace
To prevent severe burns
and injuries, do Not
remove the barrier on the
appliance which prevents
direct contact with the
glass.
Follow the safety instructions below
and be sure everyone in your household
understands this burn hazard:
The surfaces on your fireplace get
EXTREMELY HOT!
The glass on the front of the
fireplace reaches EXTREMELY HIGH
temperatures and can cause severe
burns if touched.
Keep children away from an operating
fireplace. Closely supervise children
in any room where a fireplace is
operating to prevent contact with glass.
Keep clothing, furniture, gasoline, and
other flammable liquids away from the
fireplace.
Even after the gas is turned off,
fireplace surfaces remain extremely
hot.
Be sure to attach the enclosed Safety-
in-Operation Warnings where you
turn on your fireplace, to help remind
everyone of the dangers associated with
high temperatures
(Page 35)
.
Read Important Safety Information
(Pages 4-5)
.
All parts of your
IHP fireplace get
EXTREMELY HOT!
Toutes les parties de votre
foyer IHP deviennent
EXTRÊMEMENT CHAUDES !
¡Todas las partes de la
chimenea IHP se ponen
MUY CALIENTES!
4
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
General Information
900608-00, 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
TABLE OF CONTENTS
Safety and Your Fireplace ......................... Page 2
Packaging ................................................Page 4
Introduction .............................................Page 4
General Information ................................. Page 4
Requirements for the
Commonwealth of Massachusetts ........Page 6
Cold Climate Insulation ............................ Page 6
Manufactured Home Requirements .........Page 7
Location ................................................... Page 7
Vent Termination Clearances ...................Page 8
Appliance and Vent Clearances ................Page 10
Detailed Installation Steps ........................Page 12
Typical Installation Sequence .................. Page 12
Step 1. Framing ........................................Page 12
Fireplace and Framing Specifications ........Page 13
Step 2. Routing Gas Line .........................Page 15
Step 3. Appliance Vent Collar ................... Page 15
Step 4. Install The Venting System ..........Page 16
Vertical Termination Systems ...................Page 17
Vent Section Length Charts ......................Page 17
Vertical Vent Tables and Figures ...............Page 21
Horizontal Termination System ................ Page 23
Horizontal Vent Tables and Figures ..........Page 25
Venting Using Flexible Vent Pipe ..............Page 28
Step 5. Field Wiring .............................. Page 29
Step 6. Connecting Gas Line ................Page 30
Step 7. Verifying Appliance Operation ......Page 31
Step 8. Installing Logs .........................Page 31
Step 9. Remove/Install Glass Door ......Page 32
Step 10. Burner Adjustments .................Page 32
Step 11. Install Front Face ...................... Page 34
Step 12. Hood Installation ...................... Page 34
Finishing Requirements ...........................Page 34
Step 13. Attaching Safety in
Operation Warnings .......................Page 35
Installation Accessories ...........................Page 36
Gas Conversion Kits ........................Page 38
Operation .................................................Page 40
Gas Controls Access ................................ Page 41
Variable Flame Adjustment .......................Page 41
Attaching Safety in Operation Warnings ...Page 42
Maintenance .............................................Page 43
Front Glass Enclosure Panel,
Removal and Installation ........................Page 44
Install Vermiculite, Embers
and Logs ............................................... Page 45
Burner Flame Appearance/Sooting ...........Page 48
Burner Flame Adjustments .......................Page 48
Millivolt Appliance Checkout .................... Page 48
Wiring Diagrams ...................................... Page 49
Replacement Parts ...................................Page 49
Product Reference Information ................Page 49
Accessory Components ...........................Page 50
Maintenance Schedule ............................. Page 52
Lighting Instructions – Millivolt ...............Page 53
Troubleshooting Guide – Millivolt.............Page 55
Replacement Parts List ............................ Page 56
Warranty ..................................................Page 57
Please read and understand these
instructions before beginning your
installation.
PACKAGING
The assembled vented gas fireplace heater is
packaged with:
1 - one log set located within the firebox.
2 - one plastic bag containing the literature
package, which consists of (2 ea.) Instal-
lation and Operation manuals (one for the
installer and one to be left with the appliance
for the homeowner), hot glass warning
flyer, glass and barrier flyer, warning labels,
8 (MHD40ST), and 4 (MHD40PF) nailing
flanges.
3 - two hoods (MHD40ST), or three hoods
(MHD40PF) taped to the top of the fireplace.
4 - one plastic bag of glowing embers, one
plastic bag of decorative volcanic stone
and one bag of vermiculate is located in
the bottom control compartment.
5 - one vent restrictor to be applied as shown on
Page 16; restrictor is taped to the envelope.
6 - barriers
7 - front face assemblies
8 - one fuel conversion kit (Nat. Gas to LP Gas)
located in the bottom control compartment.
NOTE:
If the barrier becomes dam-
aged, the barrier shall be re-
placed with the manufacturer’s
barrier for this appliance.
For use with barrier(s) Part
No(s). J7420 (ST Models),
J7420 and J7421 (PF Models).
INTRODUCTION
These Millivolt appliances have a millivolt gas
control valve with piezo ignition system. If any
optional accessories that will require electrical
power are to be installed, the electrical power
must be provided at the time of appliance instal-
lation. External electrical power is required to
operate the (optional) forced-air blower.
These vented gas fireplace heaters are sealed
combustion, air-circulating gas fireplaces de-
signed for residential applications.
Approved Vent Components - These fireplaces
are designed, tested and listed for operation
and installation with the following vent com-
ponents only:
Secure Vent
®
Direct-Vent System Compo-
nents manufactured by IHP.
Secure Flex
®
Flexible Vent Components
manufactured by IHP and
Z-FLEX
®
Model GA Venting Systems listed
to UL1777 and ULCS635 manufactured by
Flexmaster Canada Limited.
Use only the correct size venting (4-1/2" inner
and 7-1/2" outer).
These approved vent system components are
labeled for identification. DO NOT use any
other manufacturer’s vent components with
these appliances.
Children and adults should be alerted to the
hazards of high surface temperature and
should stay away to avoid burns or clothing
ignition.
Les enfants et les adultes devraient être infor-
més des dangers que posent les températures
de surface élevées et se tenir à distance afin
d’éviter des brûlures ou que leurs vêtements
ne s’enflamment.
DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATION AND LISTINGS OF THIS UNIT.
WARNING
Young children should be care-
fully supervised when they are
in the same room as the appli-
ance. Toddlers, young children
and others may be susceptible
to accidental contact burns. A
physical barrier is recommended
if there are at-risk individuals in
the house. To restrict access to
a fireplace or stove, install an
adjustable safety gate to keep
toddlers, young children and
other at-risk individuals out of
the room and away from hot
surfaces.
AVERTISSEMENT
Les jeunes enfants devraient être
surveillés étroitement lorsqu’ils
se trouvent dans la même pièce
que l’appareil. Les tout petits,
les jeunes enfants ou les adultes
peuvent subir des brûlures s’ils
viennent en contact avec la sur-
face chaude. Il est recommandé
d’installer une barrière physique
si des personnes à risques habi-
tent la maison. Pour empêcher
l’accès à un foyer ou à un poêle,
installez une barrière de sécu-
rité; cette mesure empêchera les
tout petits, les jeunes enfants et
toute autre personne à risque
d’avoir accès à la pièce et aux
surfaces chaudes.
GENERAL INFORMATION
5
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
General Information
900608-00, 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
WARNING
Improper installation, adjust-
ment, alteration, service or
maintenance can cause injury
or property damage. Refer to
this manual. For assistance or
additional information consult
a qualified installer, service
agency or the gas supplier.
WARNING
Failure to comply with these
installation instructions will result
in an improperly installed and
operating appliance, voiding its
warranty. Any change to this appli-
ance and/or its operating controls
is dangerous.
WARNING
Clothing or other flammable
material should not be placed
on or near the appliance.
AVERTISSEMENT
On ne devrait pas placer de
vêtements ni d’autres matières
inflammables sur l’appareil ni à
proximité.
WARNING
Any safety screen, guard, or
barrier removed for servicing
an appliance must be replaced
prior to operating the appliance.
AVERTISSEMENT
Tout écran ou protecteur retiré
pour permettre l’entretien de
l’appareil doit être remis en
place avant de mettre l’appareil
en marche.
NOTE: Installation and repair should be done
by a qualified service person. The appliance
should be inspected before use and at least
annually by a professional service person.
More frequent cleaning may be required due
to excessive lint from carpeting, bedding ma-
terial, et cetera. It is imperative that control
compartments, burners and circulating air
passageways of the appliance be kept clean.
Remarque: L’installation et la réparation
devrait être confiées à un technicien qualifié.
L’appareil devrait faire l’objet d’une inspection
par un technicien professionnel avant d’être
utilisé et au moins une fois l’an par la suite.
Des nettoyages plus fréquents peuvent être
nécessaires si les tapis, la literie, et cetera
produisent une quantité importante de pous-
sière. Il est essentiel que les compartiments
abritant les commandes, les brûleurs et les
conduits de circulation d’air de l’appareil
soient tenus propres.
Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water.
Ne pas se servir de cet appareil s’il a été
plongé dans l’eau, même partiellement.
Faire inspecter l’appareil par un technicien
qualifié et remplacer toute partie du sys-
tème de contrôle et toute commande qui
ont été plongées dans l’eau.
Misc. Codes / Standards -
The Installation must conform to local codes or,
in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54—latest
edition, or the Natural Gas and Propane Instal-
lation Code, CAN/CGA B149.1.
The appliance, when installed, must be electri-
cally grounded and wired in accordance with
local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA
70—latest edition, or the Canadian Electrical
Code, CSA C22.1—latest edition.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front or back openings of the appliance.
These appliances are designed to operate on
natural or propane gas only. The use of other
fuels or combination of fuels will degrade
the performance of this system and may be
dangerous.
These fireplaces are designed as supplemental
heaters. Therefore, it is advisable to have an
alternate primary heat source when installed
in a dwelling.
Millivolt Models - The millivolt appliances are
manually controlled and feature a spark igniter
(piezo) that allows the appliance's pilot gas to
be lit without the use of matches or batteries.
This system provides continued service in the
event of a power outage.
Millivolt models come standard with a manually-
modulated gas valve; flame appearance and heat
output can be controlled at the gas valve. The BTU
Input for these appliances is shown in Table 1.
Only trim kit(s) supplied by the manufacturer
shall be used in the installation of this ap-
pliance.
Seules les trousses de garniture fournies
par le fabricant doivent être utilisées pour
l’installation de cet appareil.
These appliances comply with National Safety
Standards and are tested and listed by PFS
(Report No. 14-171) to ANSI Z21.88 (in Canada,
CSA-2.33), and CAN/CGA-2.17-M91, latest edi-
tions, in both USA and Canada, as vented gas
fireplace heaters.
These appliances are listed by PFS for instal-
lation in bedrooms and Manufactured Homes.
WARNING
Improper installation or use of
this appliance can cause serious
injury or death from fire, burns,
explosions or carbon monoxide
poisoning.
WARNING
This product can expose you
to chemicals including Carbon
Black, which is known to the State
of California to cause cancer, and
Carbon Monoxide, which is known
to the State of California to cause
birth defects or other reproductive
harm. For more information go to
www.P65Warnings.ca.gov
AVERTISSEMENT
Ce produit peut vous exposer
à des produits chimiques, y
compris du carbone noir qui est
reconnu par l'État de Californie
comme un produit cancérigène,
et du monoxyde de carbone, qui
est reconnu par l'État de Califor-
nie comme pouvant causer des
déformations fœtales ou per-
turber la fonction reproductive.
Pour plus d’information, aller
sur www.P65Warnings.ca.gov
6
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
General Information
900608-00, 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
Test gauge connections are provided on the
front of the millivolt gas control valve (identi-
fied IN for the inlet and OUT for the manifold
side). The control valves have a 3/8" (10mm)
NPT thread inlet and outlet side of the valve
(refer to Figure 1).
Propane tanks are at pressures that will cause
damage to valve components. Verify that the
tanks have step down regulators to reduce the
pressure to safe levels.
Gas Valve Diagrams
See Figure 1 for Millivolt models.
Manifold Gas Supply Pressure (all models)
Fuel # Low High
Natural
Gas
(Lo) 2.2" WC
(0.55 kPa)
(Hi) 3.5" WC
(0.87 kPa)
Propane
(Lo) 6.3" WC
(1.57 kPa)
(Hi) 10.0" WC
(2.49 kPa)
Table 3
The appliance and its appliance main gas
valve must be disconnected from the gas
supply piping system during any pressure
testing of that system at test pressures in
excess of 1/2 psi (3.5 kPa).
The appliance must be isolated from the
gas supply piping system by closing its
equipment shutoff valve during any pressure
testing of the gas supply piping system at
test pressures equal to or less than 1/2 psi
(3.5 kPa).
Orifice Sizes - Sea Level to High Altitude
(All Models)
These appliances are tested and approved for
installation at elevations of 0-4500 feet (0-1372
meters) above sea level using the standard burner
orifice sizes (marked with an "*" in Table 4).
For elevations above 4500 feet, contact your
gas supplier or qualified service technician.
Deration - At higher elevations, the amount
of BTU fuel value delivered must be reduced
by either:
• Using gas that has been derated by the gas
company.
• By changing the burner orifice to a smaller
size as regulated by the local authorities having
jurisdiction and by the (USA) National Fuel Gas
Code NFPA 54/ANSI Z223.1—latest edition or,
in Canada, the CAN/CGA-B149.1 codes—latest
edition.
Install the appliance according to the regulations
of the local authorities having jurisdiction and,
in the USA, the National Fuel Gas Code NFPA
54 / ANSI Z223.1—latest edition or, in Canada,
the CAN/CGA-B149.1—latest edition.
Flame breadth, height and width will diminish
4% for every 1,000 feet of altitude.
COMMONWEALTH OF MASSACHUSETTS
REQUIREMENTS
These appliances are approved for installation in
the US state of Massachusetts if the following
additional requirements are met:
Install this appliance in accordance with
Massachusetts Rules and Regulations 248
C.M.R. Sections 4.00 through 8.00.
Installation and repair must be done by a
plumber or gas fitter licensed in the Com-
monwealth of Massachusetts.
The flexible gas line connector used shall
not exceed 36 inches (92 centimeters) in
length.
The individual manual shutoff must be a
T-handle type valve.
Massachusetts Horizontal Vent Requirements
In the Commonwealth of Massachusetts, hori-
zontal terminations installed less than seven
(7) feet above the finished grade must comply
with the following additional requirements:
A hard wired carbon monoxide detector
with an alarm and battery back-up must be
installed on the floor level where the gas
fireplace is installed. The carbon monoxide
detector must comply with NFPA 720, be
ANSI/UL 2034 listed and be ISA certified..
A metal or plastic identification plate must
be permanently mounted to the exterior of
the building at a minimum height of eight (8)
feet above grade and be directly in line with
the horizontal termination. The sign must
read, in print size no less than one-half (1/2)
inch in size, GAS VENT DIRECTLY BELOW.
KEEP CLEAR OF ALL OBSTRUCTIONS.
COLD CLIMATE INSULATION
For cold climate installations, seal all cracks
around your appliance with noncombustible
material and wherever cold air could enter
the room. It is especially important to insulate
outside chase cavity between studs and under
floor on which appliance rests, if floor is above
ground level. Gas line holes and other open-
ings should be caulked or stuffed with unfaced
fiberglass insulation.
If the fireplace is being installed on a cement
slab in cold climates, a sheet of plywood or
other raised platform can be placed underneath
to prevent cold transfer to the fireplace and into
the room. It also helps to sheetrock inside
surfaces and tape for maximum air tightness
and caulk firestops.
Inlet Gas Supply Pressure (all models)
Fuel # Minimum Maximum
Natural Gas
4.5" WC
(1.12 kPa)
10.5" WC
(2.61 kPa)
Propane
11.0" WC
(2.74 kPa)
13.0" WC
(3.23 kPa)
Table 2
Gas Pressure - All Models
Tables 2 and 3 show the appliances' inlet and
manifold gas pressure requirements:
H
I
L
O
W
HTPTHTPT
P
I
L
O
T
P
I
L
O
T
O
N
it
O
F
F
IN
OUT
HI/LO Variable
Flame Height
Adjustment
Figure 1 - SIT Millivolt Gas Valve
Manifold Pressure Tap
Inlet Pressure Tap
Pilot Adjustment
Screw
Main Gas Control Knob
OFF/PILOT/ON
Burner Orifice Sizes (all models) *
Model
Natural Gas
drill size (inches)
Propane Gas
drill size (inches)
ST and PF
#32 (0.116")
37L82
1.65mm (0.065")
74L88
Table 4
Standard size installed at factory
Standard size if field converted
Part /Cat. Number
*For elevations of 0-4500 ft. or 0-1372 m
Input (BTU) Gas Valves (all models)
Models Ignition
Fuel Type
Input Rate
(BTU / HR)
ST and PF Natural
37,000 high
29,000 low
ST and PF Propane*
34,000 high
27,000 low
Table 1 *if field converted
These appliances comply with CSA P.4.1-2015
“Testing Method for Measuring Annual Fireplace
Efficiency. P4 (EnerGuide) is a measurement of
the Canadian Office of Energy Efficiency.
Based on CSA P. 4.1-2015
7
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
General Information
900608-00, 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
LOCATION
In selecting the location, the aesthetic and functional use of the appliance are primary concerns.
However, vent system routing to the exterior and access to the fuel supply are also important.
Due to high temperatures, the appliance should be located out of traffic and away from furniture
and draperies (Figure 2).
En raison des températures élevées, l’appareil devrait être installé dans un endroit où il y a
peu de circulation et loin du mobilier et des tentures (Figure 2).
The location should also be free of electrical, plumbing or other heating/air conditioning ducting.
These direct-vent appliances are uniquely suited for installations requiring a utility shelf positioned
directly above the fireplace. Utility shelves like these are commonly used for locating television
sets and decorative plants.
MANUFACTURED HOME
REQUIREMENTS
This appliance may be installed as an OEM
installation in a manufactured home (USA
only) or mobile home and must be installed in
accordance with the manufacturer’s instructions
and the Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280, in the
United States, or the Standard for Installation in
Mobile Homes, CAN/CSA Z240 MH, in Canada.
Cet appareil peut être installé comme
du matériel d'origine dans une maison
préfabriquée (É.-U. seulement) ou mobile
et doit être installé selon les instructions
du fabricant et conformément à la norme
Manufactured Home Construction and
Safety Standard, Title 24 CPF, Part 3280
ou à la norme CAN/CSA Z240 Série MM,
Maisons Mobiles.
Manufactured Home installations must be
installed in accordance with these instructions
and the following standards / codes:
• (when applicable) The American National
Standard for Manufactured Homes (NCSBCS
/ ANSI A225.1 - latest edition).
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA
only) or Mobile Home, where not prohibited by
local codes.
Cet appareil peut être installé dans un
maison préfabriquée (É.-U. seulement)
ou mobile déjà installée à demeure si les
réglements locaux le permettent.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certified kit is used.
Cet appareil doit être utilisé uniquement
avec le type de gaz indiqué sur la plaque
signalétique. Cet appareil ne peut être
converti à d'autres gaz, sauf si une trousse
de conversion est utilisée.
Figure 2 - Typical Location
When the unit is installed with one side flush with a wall,
the wall on the other side of the unit must not extend
beyond the front edge of the unit.
(See-Through Model Shown)
See-Through
(ST)
Peninsula
(PF)
See-Through
(ST)
one side flush with a wall
VERTICAL VENT
HORIZONTAL VENT
- REAR
HORIZONTAL VENT
- TOP
CAUTION
Ensure that the cross members
are not cut or weakened during
installation. The structural integ-
rity of the manufactured home
floor, wall, and ceiling / roof must
be maintained.
This appliance must be grounded
to the chassis of the manufactured
home in accordance with local
codes or in the absence of local
codes, with the National Electri-
cal Code ANSI / NFPA 70 - latest
edition or the Canadian Electrical
Code CSA C22.1 - latest edition.
8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
General Information
900608-00, 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
12
X
Roof Pitch is X/12
2 FT
MIN.
2 FT MIN.
Lowest
Discharge
Opening
H*
*H = MINIMUM HEIGHT FROM ROOF TO
LOWEST DISCHARGE OPENING OF VENT
TERMINATION HEIGHTS FOR VENTS ABOVE
FLAT OR SLOPED ROOFS
Horizontal Overhang
Vertical
Wall
Vent
Termination
Storm Collar
Concentric
Vent Pipe
Flashing
1 inch (26 mm) Minimum
Clearance to Combustibles
Figure 4
Vertical Vent Termination Clearances
Be aware that this is a heat producing ap-
pliance. Objects placed above the unit are
exposed to elevated temperatures.
Do not insulate the space between the ap-
pliance and the area above it (see Figure 8).
The minimum height from the base of the appli-
ance to the underside of combustible materials
used to construct a utility shelf in this fashion
is shown in Figure 8.
The appliance should be mounted on a fully
supported base extending the full width and
depth of the unit. The appliance may be located
on or near conventional construction materials.
However, if installed on combustible materials,
such as carpeting, vinyl tile, etc., a metal or
wood barrier covering the entire bottom surface
must be used.
VENT TERMINATION CLEARANCES
These instructions should be used as a
guideline and do not supersede local codes
in any way. Install venting according to local
codes, these instructions, the current National
Fuel Gas Code (ANSI-Z223.1) in the USA or
the current standards of CAN/CGA-B149.1
in Canada.
Vertical Vent Termination Clearances
Terminate multiple vent terminations according to
the installation codes listed above and Figure 3.
NOTE: See Figure 36 on Page 24 for the exterior wall recess
allowances of the square horizontal termination.
Termination Heights For Vents
Above Flat Or Sloped Roofs
Ref. NFPA 54 / ANSI Z223.1
Roof Pitch * Feet * Meters
Flat to 6/12 1.0 0.3
6/12 to 7/12 1.25 0.38
7/12 to 8/12 1.5 0.46
8/12 to 9/12 2.0 0.61
9/12 to 10/12 2.5 0.76
10/12 to 11/12 3.25 0.99
11/12 to 12/12 4.0 1.22
12/12 to 14/12 5.0 1.52
14/12 to 16/12 6.0 1.83
16/12 to 18/12 7.0 2.13
18/12 to 20/12 7.5 2.29
20/12 to 21/12 8.0 2.44
The vent / air intake termination clearances
above the high side of an angled roof is as
shown in the following chart:
Figure 5
6"
(152 mm)
12"
(305 mm)
Combustible Projection greater
Horizontal Vent Termination Clearances
Combustible Projection
2-1/2
inches or less in length
18"
(457 mm)
Ventilated
Soffit
Unventilated
Soffit
than 2-1/2 inches in length
Termination Kit
Side Elevation View
Termination Kit
All horizontal terminations
may be located as close as
6” (152mm) to any
(non-combustible and
combustible) exterior
sidewall. This distance
may be decreased to 2”
(51mm) for non--
combustible exterior
sidewalls only, if the
SV4.5HT-2 termination
is used.
Horizontal Vent Termination Clearances
The horizontal vent termination must have a minimum of 6" (152 mm) clearance to any overhead
combustible projection of 2-1/2" (64 mm) or less (see Figure 5). For projections exceeding 2-1/2"
(64 mm), see Figure 5. For additional vent location restrictions refer to Page 9.
Figure 3 - Multiple Terminations
12”
(305mm)
Minimum
These appliances must not be connected to a
chimney or flue serving a separate solid fuel
burning appliance.
9
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
General Information
900608-00, 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
Figure 6
EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS
Fixed
Closed
Openable
Fixed
Closed
V
V
V
V
V
V
X
X
V
X
G
G
J
F
B
B
K
H
I
A
E
L
D
B
M
C
B
V
V
A
G
G
B
TERMINATION CAP
AIR SUPPLY INLET
GAS METER RESTRICTED AREA
(TERMINATION PROHIBITED)
Openable
See Figure 4
V
V
Inside Corner
V
V
Outside Corner Recessed Location
Balcony with No Side
Wall
V
Balcony with Perpendicular Side Wall
G
F
M
M
N
P
O
Q
U.S. Installation ** Canadian Installation *
A
Clearance above grade, veranda, porch, desk, or balcony 12” (300 mm) ** 12” (300 mm) *
B
Clearance to window or door that may be opened 6” (150 mm)
for fireplaces < 10,000 Btu/h (3 kW),
9” (230 mm)
for fireplaces > 10,000 Btu/h (3 kW), and < 50,000 Btu/h (15
kW),
12” (300 mm)
for fireplaces > 50,000 Btu/h (15 kW) **
6” (150 mm)
for fireplaces < 10,000 Btu/h (3 kW),
12” (300 mm)
for fireplaces > 10,000 Btu/h (3 kW)
C
Clearance to permanently closed window 9” (229 mm)
recommended to prevent window condensation
12” (305 mm)
recommended to prevent window
condensation
D
Vertical clearance to ventilated soffit located above the
termination within a horizontal distance of 18” (458 mm)
18” (458 mm) 18” (458 mm)
E
Clearance to unventilated soffit 12” (305 mm) 12” (305 mm)
F
Clearance to outside corner 5” (127 mm)
minimum
5” (127 mm)
minimum
G
Clearance to inside corner 6” (152 mm) minimum 6” (152 mm) minimum
H
Clearance to each inside of center line extended above
meter / regulator assembly
36” (910 mm)
within a height of 15 ft above the meter / regulator assembly **
36” (910 mm)
within a height of 15 ft above the meter /
regulator assembly *
I
Clearance to service regulator vent outlet 36” (910 mm)** 36” (910 mm)*
J
Clearance to non-mechanical air supply inlet to building or
the combustion air inlet to any other fireplace
6” (150 mm)
for fireplaces < 10,000 Btu/h (3 kW),
9” (230 mm)
for fireplaces > 10,000 Btu/h (3 kW) and < 50,000 Btu/h (15 kW),
12” (300 mm)
for fireplaces > 50,000 Btu/h (15 kW)**
6” (150 mm)
for fireplaces < 10,000 Btu/h (3 kW),
12” (300 mm)
for fireplaces > 10,000 Btu/h (3 kW)
K
Clearance to a mechanical air supply inlet 36” (910 mm) above if within 10 ft (3 m) horizontally ** 72” (1830 mm) *
L
Clearance above paved sidewalk or paved driveway located
on public property
84” (2130 mm) ‡ 84” (2130 mm) ‡
M
Clearance under veranda, porch, deck or balcony 12” (300 mm) *‡ 12” (300 mm) *‡
N
Depth of alcove (maximum) 72” (1830 mm) ** 72” (1830 mm) *
O
Clearance to termination (alcove) 6” (15.2 mm) ** 6” (15.2 mm)*
P
Width of alcove (minimum) 36” (910 mm) ** 36” (910 mm) *
Q
Clearance to combustible above (alcove) 18” (457 mm) ** 18” (457 mm) *
*
**
*‡
In accordance with the current CAN/CGA-B149.1 National Gas And Propane Installation Code
In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings
Only permitted if veranda, porch, deck, or balcony is fully-open on a minimum two sides beneath the floor
10
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
General Information
900608-00, 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
Hearth Extension - A hearth extension is not
required with this appliance. If a hearth exten-
sion is used, do not block the lower control
compartment door. Any hearth extension used
is for appearance only and does not have to
conform to standard hearth extension instal-
lation requirements.
Shelf Height - To provide for the lowest pos-
sible shelf surface, use the alternate rear vent
outlet, the venting attached to the top vent should
be routed in a way to minimize obstructions to
the space above the appliance. Do not insulate
the space between the appliance and the area
above it (see Figure 8). The minimum height
from the base of the appliance to the underside
of combustible materials used to construct a
utility shelf in this fashion is shown in Figure 8.
The appliance should be mounted on a fully
supported base extending the full width and
depth of the unit. The appliance may be located
on or near conventional construction materials.
However, if installed on combustible materials,
such as carpeting, vinyl tile, etc., a metal or
wood barrier covering the entire bottom surface
must be used.
Wall Finishes / Surrounds / Mantels
NOTE: Combustible wall finish materials and/
or surround materials must not be allowed to
encroach the area defined by the appliance front
face (black sheet metal). Never allow combus-
tible materials to be positioned in front of or
overlapping the appliance face (see Figure 55
on Page 34).
Minimum clearance requirements include any
projections such as shelves, window sills,
mantels, etc. above the appliance.
Non-combustible materials, such as surrounds
and other appliance trim, may be installed on
the appliance face with these exceptions: they
must not cover any portion of the removable
glass panel or control compartment.
Vertical installation clearances to combustible
mantels vary according to the depth of the
mantel. See Figure 7. Mantels constructed of
non-combustible materials may be installed
at any height above the appliance opening;
however, do not allow anything to hang below
the fireplace hood.
NOTE: To avoid heat-related finish damage, we
recommend the use of high temperature paint
(rated 175° F or higher) on the underside of
the mantel.
MINIMUM CLEARANCES TO COMBUSTIBLES
Appliance And Vent Clearances
The appliance is approved with zero clearance to combustible materials on all sides (as detailed
in Table 5), with the following exception: When the unit is installed with one side flush with a
wall, the wall on the other side of the unit must not extend beyond 6" from the front edge of
the unit as shown in Figure 2.
*NOTE: 3" (77 mm) above any horizontal/inclined vent component.
**NOTE: See Step 1, Page 12 and Figure 12, Page 13 for clearance requirements to the nailing
flange located at each side of the unit and any screw heads adjacent to it.
inches (millimeters)
Figure 8 - Shelf Height Minimum Clearances
Top of
Appliance
Figure 7 - Minimum Mantel Clearances
4 (102)
2
(51)
4
(102)
6
(152)
8
(203)
10
(254)
12
(305)
6 (152)
10 (254)
14 (356)
12 (305)
8 (203)
Shelf Above Fireplace
With Rear Venting
Do not insulate the
space between the
appliance and the
area above it.
Shelf Height
(see table)
Shelf Above Fireplace
With Top Venting
Do not insulate the
space between the
appliance and the
area above it.
Shelf Height
(see table)
Mantel Depth
Front or Rear Face
of Appliance
Model No.
Combustible Shelf Height - Inches (millimeters)
Top Vent - with One 90 Degree Elbow Rear Vent - Straight Out the Back
Secure Vent
®
Secure Flex
®
Secure Vent Secure Flex
MHD40ST
MHD40PF
53-7/8 (1368)* 55-5/8 (1413)* 41-1/8 (1045) 41-1/8 (1045)
* Includes 3” clearance to combustibles (required above vent components)
11
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
General Information
900608-00, 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
MINIMUM CLEARANCES* Inches (millimeters)
Back and Sides 1/2 (13)
0 (0) from Spacers Or Dimples **
Top Spacers 0 (0)
Floor 0 (0)
From Bottom of Unit To Ceiling 64 (1626)
Vent 3 (77) Top* / 1 (26) Sides & Bottom
SERVICE CLEARANCES Feet (meters)
Front, Back, Sides 3 feet (0.9 meters)
Table 5
Figure 10 - Unit Parts Identification
Top View of
Fireplace
Combustible Walls
A Combustible Wall
may extend to any
length on one side
only. If installed as
shown, opposite side
is limited to 6".
6"
Figure 9
Control Compartment Access Panel
Front face assembly
Barrier
Control Compartment (behind assembly)
Hood
Installation
900608-00 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
12
Figure 11
REMOVE
CARDBOARD
BEFORE USING
Pressure Relief
Plates
Remove Cardboard Before
Using Appliance
REMOVE
CARDBOARD
BEFORE USING
WARNING
Failure to position the parts in
accordance with these diagrams
or failure to use only parts
specifically approved with this
appliance may result in property
damage or personal injury.
AVERTISSEMENT
Risque de dommages ou de
blessures si les pièces ne sont
pas installées conformément à
ces schémas et ou si des pièces
autres que celles spécifiquement
approuvées avec cet appareil
sont utilisées.
DETAILED INSTALLATION STEPS
The appliance is shipped with all gas controls
and components installed and pre-wired.
1. Remove the shipping carton.
2. Remove Front Face Assembly by lifting and
pulling straight out from the fireplace.
3. Lift the pressure relief plates and remove
the cardboard from underneath each of
them.
4. Open the two latches (located under the
firebox floor) securing the glass enclosure
panel. Remove the panel by tilting it outward
at the bottom and lifting it up. Set the door
aside protecting it from inadvertent damage.
See Figure 63 on Page 44.
TYPICAL INSTALLATION SEQUENCE
The typical sequence of installation is outlined
below. However, each installation is unique and
may result in variations to the steps described.
See the Page numbers references in the follow-
ing steps for detailed procedures.
Step 1. (Page 12) Construct the appliance
framing. Position the appliance within the
framing and secure with nailing brackets (refer
to Figure 12, Page 13).
Step 2. (Page 15) Route gas supply line to
appliance location.
Step 3. Preparing the appliance vent collar
(Page 15).
Step 4. (Page 16) Install the vent system and
exterior termination.
Step 5. (Page 29) Field Wiring
(If the optional blower is installed) Install the
operating control switch (not factory provided)
and bring in the electrical service line.
Step 6. (Page 30) Make connection to gas
supply.
Step 7. (Page 31) Verifying appliance operation.
Step 8. (Page 31) Install the logs, decorative
volcanic stone and glowing embers.
Step 9. (Page 32) Install glass door assembly.
Step 10. (Page 32) Adjust burner to ensure
proper flame appearance.
Step 11. (Page 34) Install front face assembly
with barrier.
Step 12. (Page 34) Install the hoods.
Step 13. (Page 35) Attach Safety in Operation
Warnings.
Before proceeding it may be helpful to remove
the log set form the firebox and remove the
embers and volcanic stone from the control
compartment. Refer to the following steps:
1. Remove the front glass enclosure panel
(see Removing and Installing Glass Enclosure
Panels on Page 32).
2. Remove log set box from firebox. Next,
remove embers and volcanic stone from con-
trol compartment. Handle logs carefully to
prevent breakage.
Step 1. FRAMING
Frame these appliances as illustrated in Figures
13 (MHD40ST) and 14 (MHD40PF), Page 13.
All framing details must allow for a minimum
clearance to combustible framing members as
shown in Table 5 on Page 11. If the appliance
is to be elevated above floor level, a solid con-
tinuous platform must be constructed. Headers
may be in direct contact with the appliance top
spacers but must not be supported by them or
notched to fit around them. All construction
above the appliance must be self supporting, DO
NOT use the appliance for structural support.
Side Nailing Flanges
The fireplace should be secured to the framing
at the side(s) and/or rear of the unit using the
factory-provided nailing flanges. Install the nailing
flanges - 8 (MHD40ST) and 4 (MHD40PF) - as
shown in Figure 12 using the existing screws.
Position the fireplace within the framing. When
required, the flanges may be bent 90 degrees by
hand or with the assistance of a hammer. Use
wood screws to secure the nailing flanges to
the framing. See Table 5 on Page 11 for clear-
ances of framing members to cabinet parts in
the nailing flange area. The nailing flange itself
is exempt from these clearances.
Floor Nailing Tabs
Secure the fireplace to the floor as shown in
Figure 12, Page 13.
Installation
900608-00 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
13
Gas Line
Center of gas line
is 3” (76 mm)
up from floor.
*41-1/2
(1054)
***48-1/2
(1232)
26-3/4
(679)
11-3/8
(267)
Dimension A
Secure Vent
®
- 47-1/8 (1197)
Secure Flex
®
- 47-3/4 (1213)
7
(178)
5-1/8
(130)
12-1/8
(308)
10-1/2
**22-3/4
(578)
LibraST
(See-Through)
VENT FRAMING -
TOP VENT WITH
ONE 90º ELBOW
VENT FRAMING -
REAR VENT WITH
NO ELBOWS
inches (millimeters)
7
(178)
5-1/8
(130)
12-1/8
(308)
6-1/4
(159)
A
Minimum Framing
Stud Size is 2x4
*This dimension can be reduced to 41” (1041 mm). This results in 0” (0 mm)
clearance between framing and unit framing spacers. (The 41-1/2” dimension permits
easier fireplace installation, if unit is installed after framing is erected).
**This dimension based on 5/8” drywall.
For 1/2” drywall use 23”.
***Provide Additional Space For Side Vent
Seal Cap If Installing Against A Solid Wall
LibraPF
(Peninsula)
Gas Line
Center of gas line
is 3” (76 mm)
up from floor.
*41-1/2
(1054)
***43-5/8
(1108)
26-3/4
(679)
11-3/8
7
(178)
5-1/8
(130)
12-1/8
(308)
VENT FRAMING -
TOP VENT WITH
ONE 90º ELBOW
VENT FRAMING -
REAR VENT WITH
NO ELBOWS
inches (millimeters)
7
(178)
(130)
(308)
6-1/4
(159)
A
Minimum Framing
Stud Size is 2x4
(267)
(289)
**22-3/4
(578)
Dimension A
Secure Vent - 47-1/8 (1197)
Secure Flex - 47-3/4 (1213)
*This dimension can be reduced to 41” (1041 mm). This results in 0” (0 mm)
clearance between framing and unit framing spacers. (The 41-1/2” dimension permits
easier fireplace installation, if unit is installed after framing is erected).
**This dimension based on 5/8” drywall.
For 1/2” drywall use 23”.
***Provide Additional Space For Side Vent
Seal Cap If Installing Against A Solid Wall
10-1/2
12-1/8
5-1/8
Figure 14
Figure 13
FIREPLACE FRAMING SPECIFICATIONS
Figure 12 - Nailing Flanges and Floor Nailing Tabs
MHD40ST
(See Through)
MHD40PF
(Peninsula)
Turn tabs down and secure to the floor with
8d nails or other appropriate fasteners
on all sides of the unit which do not have
viewing glass panels.
LibraST SHOWN
(LibraPF - NO NAILING FLANGES
ON END WITH GLASS PANEL)
LibraCL SHOWN
(FOR LibraCR VIEW, INTERCHANGE SIDES)
Remove these two screws and
use them when installing
the nailing flanges.
Nailing Flanges
Note: The nailing flanges, combustible members and screw heads located in areas directly adjacent to the nailing
flanges, are EXEMPT from the 1/2” clearance to combustible requirements for the firebox outer wrapper.
Combustible framing may be in direct contact with the nailing flanges and may be located closer than 1/2” from
screw heads and the firebox wrapper in areas adjacent to the nailing flanges. Frame the opening to the exact
dimensions specified in the framing details of this manual.
See Through SHOWN
(Peninsula - NO NAILING FLANGES
ON END WITH GLASS PANEL)
NOTE: The nailing flanges, combustible members and screw heads located in areas directly adjacent to the nailing flanges, are EXEMPT from the 1/2” clear-
ance to combustible requirements for the firebox outer wrapper. Combustible framing may be in direct contact with the nailing flanges and may be located
closer than 1/2” from screw heads and the firebox wrapper in areas adjacent to the nailing flanges. Frame the opening to the exact dimensions specified in
the framing details of this manual.
Installation
900608-00 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
14
10-3/8
(264)
12
(303)
3
(77)
6-7/8
(175)
41
(1041)
34-1/8
(867)
1 (26)
27-3/4 (705)
23-7/8 (607)
21-3/8 (543)
37-3/4 (959)
45-1/2 (1156)
11-3/8
(289)
10
(254)
21-3/8
(543)
TOP VIEW
FRAMING
SPACERS
(Top and
both sides)
FINISHED WALL BRACKET
(Front and back edge of unit top)
CONTROL
COMPARTMENT
ACCESS PANEL
ELECTRICAL
INLETS
GAS
iNLET
FRONT VIEW
LEFT SIDE VIEW
RIGHT SIDE VIEW
1/2
(13)
DETAIL OF
FINISH WALL BRACKET
50-3/8 (1280)
48 (1219)
48-1/4 (1226)
37-3/4 (959)
40-1/4 (1022)
41
(1041)
37
(940)
34-1/8
(867)
23-1/2
(597)
27-3/4 (705)
23-7/8 (607)
41
(1041)
2 (51)
FRAMING
SPACERS
(Top and
both sides)
FINISHED WALL BRACKET
(Front and back edge of unit top)
Stepped to accept drywall
on all four corners
1/2
(13)
DETAIL OF
FINISHED
WALL BRACKET
GAS
INLET
CONTROL
COMPARTMENT
ACCESS PANEL
TOP VIEW
FLUE SIDE VIEW
FRONT VIEW
ELECTRICAL
INLETS
FIREPLACE SPECIFICATIONS
MHD40PF (Peninsula)
MHD40ST (See-Through)
Figure 16
Figure 15
NOTE: Unit has a factory-installed
vent seal cap and vent cover plate
(see Figures 18-19 on Page 16) in
each flue outlet. The vent seal cap is
not shown in this Figure.
NOTE: Unit has a factory-installed
vent seal cap and vent cover plate
(see Figures 18-19 on Page 16) in
each flue outlet. The vent seal cap is
not shown in this Figure.
Installation
900608-00 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
15
Schedule 40
Black Iron Pipe
Inside Diameter (Inches)
Schedule 40 Pipe
Length (feet)
Natural
Gas
Propane
Gas
0-10 1/2 3/8
10-40 1/2 1/2
40-100 1/2 1/2
100-150 3/4 1/2
150-200 3/4 1/2
Table 6
IMPORTANT: If propane is used, be aware that
if tank size is too small (i.e. under 100-lbs, if
this is the only gas appliance in the dwelling.
Ref. NPFA 58), there may be loss of pressure,
resulting in insufficient fuel delivery (which
can result in sooting, severe delayed ignition
or other malfunctions). Any damage resulting
from an improper installation, such as this,
is not covered under the limited warranty.
Step 3. PREPARING THE APPLIANCE
VENT COLLAR
Proper Sizing of Gas Line
Properly size and route the gas supply line from
the supply regulator to the area where the appli-
ance is to be installed per requirements outlined
in the National Fuel Gas Code, NFPA 54—latest
edition (USA) or CAN/CGA-B149.1—latest edi-
tion (Canada).
Never use galvanized or plastic pipe. Refer to
Table 6 for proper sizing of the gas supply line,
if black iron pipe is being used. Gas lines must
be routed, constructed and made of materials
that are in strict accordance with local codes
and regulations. We recommend that a qualified
individual such as a plumber or gas fitter be
hired to correctly size and route the gas supply
line to the appliance.
Also see Figures 13 and 14.
Figure 17 - Route Gas Line
Step 2. ROUTING GAS LINE
Route a 1/2" (13 mm) gas line to the right side
of the appliance as shown in Figure 17. Gas
lines must be routed, constructed and made
of materials that are in strict accordance with
local codes and regulations. All appliances
are factory-equipped with a flexible gas line
connector and 1/2" shutoff valve. (See Step
6 on Page 30).
Installing a gas supply line from the fuel supply to
the appliance involves numerous considerations
of materials, protection, sizing, locations, con-
trols, pressure, sediment, and more. Certainly no
one unfamiliar and unqualified should attempt
sizing or installing gas piping.
5-5/8"
(143 mm)
3-1/8"
(79 mm)
NOTES:
All appliances are factory-equipped with a
flexible gas line connector and 1/2" shutoff
valve.
• See Massachusetts Requirements on Page
6 for additional requirements for installations
in the state of Massachusetts in the USA.
The gas supply line should Not be connected
to the appliance until Step 6 (Page 30).
A pipe joint compound rated for gas should be
used on the threaded joints. Ensure propane
resistant compounds are used in propane
applications. Be very careful that the pipe
compound does not get inside the pipe.
It is recommended to install a sediment trap
in the supply line as close as possible to the
appliance. Appliances using Propane should
have a sediment trap at the base of the tank.
Check with local building official for local
code requirements (i.e. are below grade
penetrations of the gas line allowed?, etc).
REMOVE VENT SEAL CAP
(From the vent that will be used only)
Top Vent Installations - See Figure 18
Side Vent Installations - See Figure 19
Preparing the Appliance Vent Collar
Each of the appliances' two vent collars are
sealed with a seal cap which must be removed
from the vent collar being used. Refer to Figure
18 for top vent installations and Figure 19 for
side vent installations and the following steps to
prepare the appropriate collar for use.
From the vent collar being used, remove the
two screws securing the vent seal cap. Twist
the cap counterclockwise. Pull it away from
the appliance and discard, along with the piece
of insulation.
WARNING
Failure to reinstall and securely
tighten vent seal cap screws
could result in leakage of flue
products into the living space.
Vent seal cap must remain
securely installed on unused
vent collar. Failure to do so
could result in leakage of flue
products into living space.
Installation
900608-00 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
16
Select Venting System - Horizontal or Vertical
With the appliance secured in framing, determine vent routing and identify
the exterior termination location. The following sections describe vertical
(roof) and horizontal (exterior wall) vent applications. Refer to the section
relating to your installation. A list of approved venting components are
shown on Pages 36 and 37.
Securing Screws
(OUTSIDE of
Appli
ance)
Insulation
Top Vent
Vent Seal Cap
Firebox Top
Cabinet Top
CROSS SECTION
SIDE VENT SEAL CAP REMOVAL
(SIDE VENT INSTALLATIONS ONLY)
Insulation
Vent Seal Cap
Securing Screws
Side Vent
Cabinet Back
CROSS SECTION
(INSIDE of Appli
ance)
(OUTSIDE of
Appli
ance)
(INSIDE of
Appli
ance)
Figure 18 -
Figure 19 -
TOP VENT SEAL CAP REMOVAL
(TOP VENT INSTALLATIONS ONLY)
Step 4. INSTALL THE VENT SYSTEM
General Information
These instructions should be used as a guideline and do not supersede
local codes in any way. Install venting according to local codes, these
instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the
USA or the current standards of CAN/CGA-B149.1 in Canada.
Ensure clearances are in accordance with local installation codes and
the requirements of the gas supplier.
Dégagement conforme aux codes d'installation locaux et aux exigences
du foumisseunde gaz.
Use only approved venting components. See Approved Vent
Components on Page 4.
These fireplaces must be vented directly to the outside.
The vent system may not service multiple appliances, and must never
be connected to a flue serving a solid fuel burning appliance. The vent
pipe is tested to be run inside an enclosed wall (such as a chase). There
is no requirement for inspection openings in the enclosing wall at any of
the joints in the vent pipe.
Figure 20
Appliance
Vent Outlet
Restrictor
Inner
Fireplace
Collar
VENT RESTRICTOR INSTALLATION
A vent restrictor may be needed when vertically terminating the vent
system above the roof (when using the appliance top vent), install a vent
restrictor in the top vent of the fireplace outlet.
If needed, install the restrictor as shown, either from inside or outside the
unit, in the inner fireplace collar.
Top Shown - Rear Similar
Installation of Vent Restrictor
A vent restrictor may be needed with this appliance. The restrictor is
installed in the appliance top flue outlet as shown in Figure 20, either
before adding vent, from above, or after installation of vent from below,
within the firebox. The restrictor is self securing through a positive
friction fit.
Determine the venting for the appliance. If the vent run will include at
least 8 feet of vertical rise, then install the restrictor in the appliance
collar before connecting any vent (Refer to Figure 20). Place the
restrictor inside the appliance vent collar and press in place.
NOTE: The restrictor is included within the firebox.
Installation
900608-00 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
17
NOTE: Convert inches into metric equivalent
measurement, as follows:
Millimeters (mm) = Inches x 25.4
Centimeters (cm) = Inches x 2.54
Meters (M) = Inches x .0254
TRAHCHTGNELNOITCESTNEV
noitceSlanimoN
)sehcni(htgneL
621426384
T
O
T
A
L
Q
T
Y
noitceSteN
)sehcni(htgneL
2/1-42/1-012/1-222/1-432/1-64
tneVfothgieHsnoitceStneVforebmuN
sehcnitf
44121100034
0515.21010034
5.451578.21110035
5.061573.31020035
5.271573.41000505
77157.41100506
38152.51010506
6815.51000044
5.091578.51100045
5.691573.61010045
5.502521.71011507
70252.71000606
5.112526.71100607
5.712521.81010607
5.922521.91001607
5.232573.91000055
73257.91100056
5.142521.02000707
6425.02100708
25212010708
46222001708
67232000808
97252.32000066
5.
082573.32100809
5.382526.32100067
5.982521.42010067
5.103521.52001067
5.013578.52000909
5135.621009001
5.523521.72000077
0335.72100078
63382010078
54357.82000 01001
5.943521.92100 01011
27313000088
5.673573.13100089
5.973526.13000 11011
5.814578.43000099
32452.531000901
56457.8300000101
SV4.5CGV-1
Termination
SV4.5FA OR
SV4.5FB Flashing
AND SV4.5SC
STORM COLLAR
*SV4.5VF
Firestop/Spacer
SV4.5L6/12/24/36/48
Vent Sections
40' Max
(12.2 M)
1" (26 mm)
Minimum
Clearance to
Combustibles
*When using Secure Flex,
use Firestop/Spacer
SF4.5VF
NOTE: Attic insulation shield (H3907,
see Page 36) must be installed when
blown or loose-fill insulation is used,
and is required for all attic installa-
tions.
Effective Vent Length
Model Effective Length
SV4.5L6 4-1/2"
SV4.5L12 10-1/2"
SV4.5L24 22-1/2"
SV4.5L36 34-1/2"
SV4.5L48 46-1/2"
Table 7
Figure 21
VERTICAL TERMINATION SYSTEMS (ROOF)
See Figure 21 and Figures 29-33 on
Pages 21 and 22 and their associated
Vertical Vent Tables which illustrate the various
vertical venting configurations that are possible
for use with these appliances. Secure Vent
®
pipe
applications are shown in these Figures; Secure
Flex
®
pipe may also be used. A Vertical Vent
Table summarizes each system’s minimum and
maximum vertical and horizontal length values
that can be used to design and install the vent
components in a variety of applications.
Both these vertical vent systems terminate
through the roof. The minimum vent height
above the roof and/or adjacent walls is speci-
fied in ANSI Z223.1-(latest edition) (In Canada,
the current CAN/CGA-B149.1 installation code)
by major building codes. Always consult your
local codes for specific requirements. A general
guide to follow is the Gas Vent Rule (refer to
Figure 4 on Page 8).
Vertical (Straight) Installation
(Figure 21)
Determine the number of straight vent sec-
tions required. 4-1/2" (114 mm), 10-1/2" (267
mm), 22-1/2" (572 mm), 34-1/2" (876 mm)
and 46-1/2" (1181 mm) net section lengths
are available (see Tables on this Page and
Page 36 - Rigid Vent Sections). Plan the vent
lengths so that a joint does not occur at the
intersection of ceiling or roof joists. Refer to
the Vent Section Length Chart.
Installation
900608-00 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
18
Figure 22
Vertical (Offset) Installation
Analyze the vent routing and determine the
quantities of vent sections and number of
elbows required. Refer to Vertical Vent Figures
and Tables on Page 21 to select the type of
vertical installation desired. Vent sections are
available in net lengths of 4-1/2" (114 mm),
10-1/2" (267 mm), 22-1/2" (572 mm), 34-1/2"
(876 mm) and 46-1/2" (1181 mm). Refer to the
Effective Vent Length Chart Table 7 on Page
17 for an aid in selecting length combinations.
Elbows are available in 90° and 45° configura-
tions. Refer to Figure 25 for the SV4.5E45 and
SV4.5E90 elbow dimensional specifications.
Where required, a telescopic vent section
(SV4.5LA) may be used to provide the installer
with an option in installing in tight and confined
spaces or where the vent run made up of fixed
length pieces develops a joint in a undesirable
location, or will not build up to the required
length. The SV4.5LA Telescopic Vent Section
has an effective length of from 1-1/2" (38 mm)
to 7-1/2" (191 mm). The SV4.5LA is fitted with
a locking inclined channel end (identical to a
normal vent section component) and a plain end
with 3 pilot holes. Slip the plain end over the
locking channel end of a standard SV4.5 vent
component the required distance and secure
with three screws.
Maintain a minimum 1" (26 mm) clearance to
combustible materials for all vertical elements.
Clearances for all horizontal elements are 3"
(77 mm) on top, 1" (26 mm) on sides and 1"
(26 mm) on the bottom.
A. Frame ceiling opening - Use a plumb line
from the ceiling above the appliance to locate
center of the vertical run. Cut and/or frame an
opening, 10-1/2" x 10-1/2" (267mm x 267mm)
inside dimensions, about this center mark
(Figure 22).
To attach a vent component to the appliance
collar, align the dimpled end over the collar,
adjusting the radial alignment until the four
locking dimples are aligned with the inlet of
the four inclined channels on the collar (refer to
Figure 23). Push the vent component against
the collar until it fully engages, then twist the
component clockwise, running the dimples
down and along the incline channels until they
seat at the end of the channels. The unitized
design of the Secure Vent components will
engage and seal both the inner and outer pipe
without the need for sealant or screws. If desired
a #6 x 1/2" screw may be used at the joint, but
it is not required as the pipe will securely lock
when twisted.
NOTE: An elbow may also be attached to the
appliance collar. Attach in the same manner as
you would a vent section.
C. Attach vent components to each other - Other
vent sections may be added to the previously
installed section in accordance with the require-
ments of the vertical vent figures and tables.
To add another vent component to a length of
vent run, align the dimpled end over the inclined
channel end of the previously installed section,
adjusting the radial alignment until the four
locking dimples are aligned with the inlets of
the four incline channels of the previous section.
Push the vent component against the previous
section until it fully engages, then twist the
component clockwise running the dimples down
and along the incline channels until they seat at
the end of the channels. This seating position
is indicated by the alignment of the arrow and
dimple as shown in Figure 23.
All of the appliances covered in this document
are fitted with collars having locking inclined
channels. The dimpled end of the vent com-
ponents fit over the appliance collar to create
the positive twist lock connection.
10-1/2" Min.
(267 mm)
10-1/2" Min.
(267 mm)
Figure 23
Align the dimple (four places) of
the upper vent section with the
opening of the locking incline
channel on the lower vent section
or appliance collar. Twist vent
component clockwise to engage
and seal until arrow and dimple
align.
Dimple
Locking Incline
Channel
Connected Vent
Sections
Arrow
Arrow
Appliance Collar or
Vent Section
B. Attach vent components to appliance -
Secure Vent
®
SV4.5 direct-vent system compo-
nents are unitized concentric pipe components
featuring positive twist lock connections (see
Figure 23).
14" Min.
Outer Pipe Of
Chimney
Use correct firestop
thimble depending on the
pitch of the interior
ceiling.
Note: Regular Thimble
(SV-FSTFE) Can Be Used
If A Header Is Constructed
At This Point
Figure 24A
D1. Install firestop/spacer at ceiling between
stories - Install a firestop/spacer (catalog no.
H2247 - Secure Vent; catalog no.H2249 - Secure
Flex) at the bottom side of the ceiling to the
ceiling joists. Route the vent sections through
the framed opening and secure the firestop/
spacer with appropriate fasteners at each corner.
Remember to maintain 1" (26 mm) clear-
ance between vertical chimney sections and
combustibles, framing members, and attic
or ceiling insulation.
D2. Install firestop thimble at the ceiling to
roof location - Position appropriate firestop
thimble (see Table on Page 33) at the bottom
side of ceiling and secure temporarily with
two appropriate fasteners. Attach permanently,
using at least two more fasteners, after vent sec-
tions have been assembled through the firestop
thimble and after any necessary adjustments
have been made.
Ensure the thimble penetrates the roof opening.
The thimble must extend completely through the
ceiling or roof cavity to the outermost plane of
the roof. Use thimble extension SVTE26 when
the distance between the outside of the roof and
the inside of the ceiling exceeds the height of
the firestop thimble. The thimble provides for
zero clearances to combustibles and must be
used at the ceiling/roof in manufactured homes
with Secure Vent double wall vent sections.
Maintain 1" (26 mm) clearance between the
thimble and the outer pipe of the secure vent
chimney system. See Figure 24B for pitched
roofs or flat roofs with flat ceilings or Figure
24A for pitched roofs with cathedral ceilings.
Installation
900608-00 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
19
Figure 24D
1” (26 mm)
Minimum
Clearance to
Combustibles
8 ft. (2.4 M)
Maximum
SV4.5VF
Firestop /
spacer
SV4.5SP
Support Plate
SV4.5SU
Support Strap
Shown With
Optional
Radiant
Panels
Secured
to Vent with
Appropriate
Fasteners
Ceiling
Framing
When
using
secure
Flex, use
Firestop/
Spacer
SF4.5VF
SV4.5FA or
SV4.5FB Flashing
and SV4.5SC
Storm Collar
SV4.5CGV-1
Termination
Attic Insulation shield
E. Support the vertical vent run sections -
NOTE: Proper venting support is very important.
The weight of the vent must not be supported
by the fireplace in any degree.
Support the vertical portion of the venting
system every 8 feet (2.4m) above the fireplace
vent outlet. One method of support is by utiliz-
ing field-provided support straps (conventional
plumber's tape). Secure the plumber's tape to
the framing members with nails or screws. Loop
the tape around the vent, securing the ends of
the tape to the framing. If desired, sheet metal
screws #6 x 1/2" length may be used to secure
the support straps to the vent pipe. Refer to
Figure 24C.
Note: Trim Thimble/
Extension To Desired Length
And Pitch At The Roof Line
14" Min.
Pitched Roof
Pitched Roof
Bow Roof
14" Min.
Outer Pipe Of
Chimney
Outer Pipe Of
Chimney
Outer Pipe Of
Chimney
14" Min.
Firestop
Thimble
Extension
13"
Firestop
Thimble
Firestop
Thimble
Thimble
SV-FSTFE
Figure 24B
Blocking
Support Straps
(Plumber's tape)
8 feet (2.4 m)
Maximum
1" (26 mm)
minimum
clearance to
combustibles
Figure 24C
Another method, where the vent is not adjacent
to a wall, is illustrated in Figure 24D. Here, sup-
port straps (96K93) and support plates (96K92)
can be used to support the weight of the vent.
F. Change vent direction to horizontal/inclined
run - At transition from or to a horizontal/in-
clined run, install the SV4.5E45 and SV4.5E90
elbows in the same manner as the straight vent
sections. The elbows feature a twist section to
allow them to be routed about the center axis
of their initial collar section to align with the
required direction of the next vent run element.
Twist elbow sections in a clockwise direction
only so as to avoid the possiblity of unlocking
any of the previously connected vent sections.
See Figure 25.
G. Continue installation of horizontal/inclined
sections - Continue with the installation of the
straight vent sections in horizontal/inclined run
as described in Step C. Install support straps
every 5' (1.52 m) along horizontal/inclined vent
runs using conventional plumber’s tape. It is
very important that the horizontal/inclined
run be maintained in a straight (no dips) and
slightly elevated plane in a direction away
from the fireplace 1/4" per foot (20 mm per
meter) of horizontal vent. Use a carpenter’s
level to measure from a constant surface and
adjust the support straps as necessary.
It is important to maintain the required clear-
ances to combustibles: 1" (26 mm) at all sides
for all vertical runs; and 3" (77 mm) at the
top, 1" (26 mm) at sides, and 1" (26 mm) at
the bottom for all horizontal/inclined runs.
Figure 25
SV4.5E90
(90
°
Elbow)
8-1/8"
(206 mm)
Swivel Joint
(360
° swivel)
4-13/16"
(122 mm)
SV4.5E45
(45
°
Elbow)
Swivel Joint
(360
° swivel)
Installation
900608-00 01/2019
Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
20
Figure 26
Figure 28
Figure 27
If the vent system extends more than 5' (1.5
m) above the roof flashing, stabilizers may be
necessary. Additional screws may be used at
section joints for added stability. Guide wires
may be attached to the joint for additional sup-
port on multiple joint configurations.
C
D
K. Install the vertical termination - The final step
involves installation of the SV4.5CGV-1 Vertical
Termination. Extend the vent sections to the
height as shown in the "Vertical vent termina-
tion section" on Page 21-22. The SV4.5CGV-1
Vertical Termination (Figure 28) installs in the
exact same fashion as any other Secure Vent
section. Align the termination over the end of
the previously installed section, adjusting the
radial alignment until the four locking dimples
of the termination are aligned with the inlets of
the four incline channels of the last vent section.
Push the termination down until it fully engages,
then twist the termination clockwise running the
dimples down and along the incline channels
until they seat at the end of the channels.
I. Install the roof flashing - Extend the vent
sections through the roof structure. Install the
roof flashing over the vent section and posi-
tion such that the vent column rises vertically
(use carpenters level) (Figure 27 ). Nail along
perimeter to secure flashing or adjust roofing to
overlap the flashing edges at top and sides only
and trim where necessary. Seal the top and both
sides of the flashing with waterproof caulking.
J. Install the storm collar - Install the storm
collar, supplied with the flashing, over the vent/
flashing joint. See Figure 27. Loosen the storm
collar screw. Slide collar down until it meets
the top of the flashing. Tighten the adjusting
screw. Apply non-combustible caulking or
mastic around the circumference of the joint
to provide a water tight seal.
H. Frame roof opening - Identify location for
vent at the roof. Cut and/or frame opening per
Roof Framing Chart and Figure 26.
Framing Dimensions for Roof
Pitch C D
0/12
10-1/2"
(267 mm)
10-1/2"
(267 mm)
6/12
10-1/2"
(267 mm)
12"
(305 mm)
12/12
10-1/2"
(267 mm)
17-3/4"
(451 mm)
Storm
Collar
Flashing
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58

Superior Fireplaces MHD40PFDMN Mode d'emploi

Catégorie
Cheminées
Taper
Mode d'emploi
Ce manuel convient également à