Miller COOL RUNNER 3X Le manuel du propriétaire

Catégorie
Système de soudage
Taper
Le manuel du propriétaire

Ce manuel convient également à

OWNER’S MANUAL
OM-2606 196 030F
May 2004
Cool Runner 3X
1. Specifications
Recirculating Coolant System For Water-Cooled GTAW Torches And GMAW Guns
Use With Guns/Torches Rated Up To 600 Amperes
3 gal (11.4 L) Coolant Tank Capacity
Cooling Unit Dimensions: 25 in (635 mm) Long, 17-7/8 in (454 mm) Wide, 8-1/4 in (235 mm) High
Cooling Unit Dimensions: 25 in (635 mm) Long, 17-7/8 in (454 mm) Wide, 8-1/4 in (235 mm) High
Housing Dimensions: 28-1/2 in (714 mm) Long, 22-1/4 in (565 mm) Wide, 11-1/8 in (283 mm) High;
Weight, 92.5 lb (42 kg)
115 Volt Models Use 5.9 Amperes, 50/60 Hertz, Single-Phase Input Power
IP Rating: 23
2. Safety Symbol Definitions
Means Warning! Watch Out! There are possible hazards
with this procedure! The possible hazards are shown in
the adjoining symbols.
Symbole graphique d’avertissement! Attention! Cette pro-
cédure comporte des risques possibles! Les dangers
éventuels sont représentés par les symboles graphiques
joints.
Have only trained and qualified persons install, operate,
or service this unit. Call your distributor if you do not un-
derstand the directions. For WELDING SAFETY and
EMF information, read wire feeder and welding power
source manuals.
L’installation, l’exploitation et l’entretien de cet appareil
doivent être confiés uniquement à des personnes
qualifiées et convenablement formées. S’adresser à un
distributeur si l’on ne comprend pas les directives. Pour
des renseignements ayant trait à la SÉCURITÉ lors du
soudage et aux champs électromagnétiques, consulter
les manuels traitant les dévidoirs et les sources de
courant pour le soudage.
Beware of electric shock from wiring.
Attention! Risque d’électrocution due au contact avec des
fils.
Beware of moving parts.
Attention! Pièces en mouvement.
Wear safety glasses with side shields.
Porter des lunettes de sécurité avec protections
latérales.
Recycle or dispose of used coolant in an environmentally
safe way.
Recycler ou éliminer tout liquide de refroidissement usé
conformément aux méthodes prescrites pour assurer la
protection de l’environnement.
OM-2606 Page 2
3. Warning Label Definitions For CE Products
S-180 663
1 2 3 4 5
6
7 8 9
1 Warning! Watch Out! There are
possible hazards as shown by the
symbols.
2 Electric shock from wiring can kill.
3 Disconnect input plug or power before
working on machine.
4 Moving parts, such as fans, can cut
fingers and hands and cause injury.
Keep away from moving parts.
5 Wear safety glasses with side shields.
6 Read the Owner’s Manual before
working on this machine.
7 Read the labels on the welding power
source, wire feeder, or other major
equipment for welding safety
information.
8 Recycle or dispose of used coolant in
an environmentally safe way.
9 Do not remove or paint over (cover)
the label.
4/96
4/96
S-178 910-A
=
043 810 HF)
043 809 (AL)
100 h. std.
21 3
6
4
7
5
1 Warning! Watch Out! There are
possible hazards as shown by the
symbols.
2 Disconnect input plug or power before
working on machine.
3 Wear safety glasses with side shields.
4 Plugged filter or hoses cause
overheating and damage.
5 Read Owners Manual.
6 Check and clean filter every 100
hours; also check condition of hoses.
7 Use Low Conductivity Coolant No. 043
810 for High-Frequency assisted or
Gas Tungsten Arc Welding
applications. Use Aluminum Protecting
Coolant No. 043 810 where coolant
contacts aluminum parts or for Gas
Metal Arc Welding applications or
where High Frequency is not used.
OM-2606 Page 3
4. Rating Label
S/N: KG085472
042288
115
5.2
COOLMATE 4
00000000000000000000
Hz50/60
IP 23
V
U
1
=
A
I
1
=
1
LR5071
INPUT
VOLTS
AMPERES
KW
PHASE HERTZ
SERIAL NO.
STOCK NO.
EVIDENCE OF LABEL TAMPERING VOIDS WARRANTY
043994
115
5.9
000000
1
50/60
COOL RUNNER 3X
S-165 371
NRTL/C
LR5071
5. Symbols And Definitions
Some symbols are found only on CE products.
NOTE
A
Amperes Alternating Current
U
1
Primary Voltage Single Phase
V
Volts
Water (Coolant) In-
put
Water (Coolant)
Output
Line Connection
Hz
Hertz
IP
Degree Of
Protection
I
1
Primary Current
OM-2606 Page 4
6. Installation And Operation
ST-802 409-A
1 Housing
2 Cooling Unit
3 Front Panel
Install housing between welding
power source base and running
gear.
Slide cooling unit into housing and
attach front panel. To remove cool-
ing unit, remove front panel, lift
cooling unit slightly and pull.
To prevent overheating, make sure
cooling unit is positioned so airflow
is not restricted.
4 Coolant Tank Cap
5 Coolant In Fitting
6 Coolant Hose
7 TIG Block (Customer Sup-
plied)
Connect coolant hose between
Coolant In fitting and TIG block lo-
cated on welding power source
Electrode weld output terminal.
8 Coolant Out Fitting
Connect hoses between cooling
unit and torch cable/TIG block cool-
ant fittings.
Y If welding power source has
a water valve, do not connect
hoses to water valve.
Use table to select proper coolant,
and fill tank. Keep coolant level full.
Operation:
9 Flowmeter
To turn cooling unit On, connect
power cord to welding power
source 115 volts ac receptacle.
Unplug to turn unit Off.
Flow indicator spins to indicate that
at least 0.53 qt/min (0.5 L/min) of
coolant is flowing.
2
1
4
6
5
7
MILLER Low Conductivity
Coolant No. 043 810**;
Distilled Or Deionized Water
OK Above 32° F (0° C)
MILLER Low Conductivity
Coolant No. 043 810**; Or
MILLER Aluminum Protecting
Coolant No. 043 809**;
Distilled Or Deionized Water
OK Above 32° F (0° C)
GTAW Or Where
HF* Is Used
GMAW Or Where
HF* Is Not Used
Application
*HF: High Frequency Current
**MILLER coolants protect to -37° F (-38°C) and resist algae growth.
Coolant
MILLER Aluminum
Protecting Coolant
No. 043 809**
Where Coolant Contacts
Aluminum Parts
3
Y Use of any coolant other than those listed in the table voids the warranty on any parts
that come in contact with the coolant (pump, radiator, etc.).
8
9
Front Of Cooling Unit
OM-2606 Page 5
7. Routine Maintenance
Y Disconnect power
before maintaining.
1 Month
Blow Out Heat
Exchanger Fins
Y Clean coolant strainer. Severe conditions
may require more frequent cleaning (continu-
ous use, high/low temperatures, dirty envi-
ronment, etc.). Failure to properly clean
coolant strainer voids pump warranty.
6 Months
Replace
Cracked
Hoses
Change
Coolant (If
Using Water)
Replace
Damaged Or
Unreadable
Labels
12 Months
Change Coolant (If Using MILLER
Coolant)
Oil
Motor
Tools Needed:
8. Coolant Maintenance And Oiling Motor
ST-801 195-A / Ref. ST-801 194
1 Coolant Filter
Unscrew housing to clean filter.
Changing coolant: Drain coolant by
tipping unit forward. Fill with clean
water and run for 10 minutes. Drain
and refill.
2 Motor
Remove top cover to access motor.
Remove plugs and put about 15
drops of SAE 20 motor oil into each
oil port. Replace plugs.
. If replacing hoses, use hoses
compatible with ethylene gly-
col, such as Buna-n, Neo-
prene, or Hypalon. NOTE:
Oxy-acetylene hoses are not
compatible with any product
containing ethylene glycol.
1
2
3/8 in
OM-2606 Page 6
9. Troubleshooting
Trouble Remedy
Coolant system does not work. Be sure input power cord is plugged in to energized receptacle.
Check line fuses or circuit breaker, and replace or reset if necessary.
Motor overheated. Unit starts running when motor has cooled.
Have Factory Authorized Service Agent check motor.
Decreased or no coolant flow. Add coolant.
Check for clogged hoses or coolant filter.
Disconnect pump, and check for sheared coupling. Replace coupling if necessary.
10. Electrical Diagram
SA-177 324-A
BLK
WHT
GRN/YEL
11
12
MOT
PLG1
115VAC.
OM-2606 Page 7
11. Parts
Figure 11-1. Cool Runner Assembly
Description Quantity
Part
No.
Item
No.
1 195 819 HOUSING 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 601 965 SCREW, .375−16 x 1.000 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 010 910 WASHER, flat 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 167 788 NUT, .375−16 .56hex x .34H stl pld sem cone wshr .88D 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 Figure 11-2 COOLING UNIT 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 192 449 LABEL, WARNING 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 196 440 PANEL, front 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 602 154 SCREW, 250-20 x .50 hexwhd 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 195 841 HOSE, water 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
To install running gear, or for a listing of running gear parts, see Owner’s manual
that is provided with the running gear.
NOTE
ST-802 409-B
BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS.
Figure 11-1. Cool Runner 3X Assembly
OM-2606 Page 8
Figure 11-2. Cooling Unit Main Assembly
Description Quantity
Part
No.
Item
No.
1 149 356 FITTING, hose brs barbed elb 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 177 166 TUBING, PVC .375 ID x .625 OD x 8.000 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 215 279 INDICATOR, flow 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 143 797 NYLON SPACER 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 136 370 TUBING, PVC .375 ID x .625 OD x 21.000 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 178 461 FILTER, bracket 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 166 564 FILTER, in-line 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 166 608 CAP, tank 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 195 804 TANK, water 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 173 263 MOTOR, 1/4hp 115VAC 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11 173 963 EXTENSION, shaft motor 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12 176 798 SCREW, set .312−24 x .375 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 195 813 COVER 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 199 195 BLOWER HOUSING W/BRACKET & BLOWER WHEEL 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16 196 515 RADIATOR 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 177 167 TUBING, PVC .375 ID x .625 OD x 31.000 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 195 818 ENCLOSURE, radiator 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19 602 212 WASHER, tooth 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20 174 042 PUMP, coolant (consisting of) 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21 134 795 COUPLER, drive pump 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22 5523 FITTING, hose brs barbed elbow m 3/8 tbg x 3/8 npt 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23 099 354 HOSE, nprn brd No. 1 X .375 ID X 8.000 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24 195 814 PANEL, front 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25 188 082 CABLE, power 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
2 3 4
5 6 7
8 9
10
11
12
15
14
15
16
17
18
19
2122
20
24
1
25
23
Ref. ST-801 676
BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS.
Figure 11-2. Cooling Unit Main Assembly
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Miller COOL RUNNER 3X Le manuel du propriétaire

Catégorie
Système de soudage
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues