Chief CPA330 Guide d'installation

Catégorie
Accessoires pour projecteurs
Taper
Guide d'installation
INSTALLATION INSTRUCTIONS
8" Off-Set Ceiling Plate
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
CPA330
CPA330 Installation Instructions
2
DISCLAIMER
Milestone AV Technologies and its affiliated corporations and
subsidiaries (collectively "Milestone"), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.
Chief® is a registered trademark of Milestone AV Technologies.
All rights reserved.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all components are
properly assembled and installed using the instructions
provided.
WARNING: Failure to provide adequate structural strength
for this component can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the structure to which this component is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components located within the mounting system of the
CPA330 does not exceed 500 lbs (226.8 kg).
The weight capacity of the CPA330 may be LIMITED to
the lowest weight capacity of any other component or
accessory used within the mounting system.
WARNING: Use this mounting system only for its intended
use as described in these instructions. Do not use
attachments not recommended by the manufacturer.
WARNING: Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING: Do not use this product outdoors.
NOTE: Accessory is intended to be used with the UL Listed
CPA Extension Column Series (not included).
IMPORTANT ! : These CPA mounts are designed to be:
mounted to a 2" x 6" wood framework ceiling;
mounted to an 8" concrete ceiling;
mounted to a suspended metal framing channel
ceiling.
WARNING: Do NOT attach to vertical mounting surfaces
such as walls or angled ceilings!
--SAVE THESE INSTRUCTIONS--
Installation Instructions CPA330
3
DIMENSIONS
TOOLS REQUIRED FOR INSTALLATION
PARTS
3.95
100.2
DIMENSIONS: INCHES
[MILLIMETERS]
1/4"
5/32"
(included)
1/2"
1/2"
nut driver
A (1)
(CPA330
Ceiling Plate)
B (4)
5/16-18 x 1"
C (4)
5/16"
D (4)
5/16"
E (1)
5/16 x 1/2"
F (1)
5/32"
CPA330 Installation Instructions
4
LEGEND
Tighten Fastener
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Loosen Fastener
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
By Hand
A mano
Von Hand
Com a mão
A mano
Met de hand
À la main
Hex-Head Wrench
Llave de cabeza hexagonal
Sechskantschlüssel
Chave de cabeça sextavada
Chiave esagonale
Zeskantsleutel
Clé à tête hexagonale
Pencil Mark
Marcar con lápiz
Stiftmarkierung
Marcar com lápis
Segno a matita
Potloodmerkteken
Marquage au crayon
Drill Hole
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Percez un trou
Optional
Opcional
Optional
Opcional
Opzionale
Optie
En option
Socket Wrench
Llave de cubo
Steckschlüssel
Chave de caixa
Chiave a brugola
Dopsleutel
Clé à douilles
Installation Instructions CPA330
5
INSTALLATION
These CPA mounts are designed for attachment to a 2" x 6"
wood framework ceiling, a concrete ceiling or a suspended
metal framing channel ceiling, and provides vertical
adjustments in 1" increments.
WARNING: Do NOT attach to vertical mounting surfaces
such as walls or angled ceilings!
WARNING: IMPROPER INSTALLATION CAN LEAD TO
LIFT FALLING CAUSING SEVERE PERSONAL INJURY OR
DAMAGE TO EQUIPMENT! It is the installer’s responsibility
to make certain the structure to which the mount is being
attached is capable of supporting five times the weight of the
CPA mount and all attached equipment. Reinforce the
structure as required before installing the mount.
NOTE: The following instructions assume a suitable mounting
structure and surface exists prior to installation.
Installing to a Wood Framework (Joists)
IMPORTANT ! : The CPA330 is designed to be mounted to
double 2" x 4" wood stud cross bracing (6-1/2" on center)
between two ceiling joists.
1. Using ceiling plate (A) as a template, mark locations of four
pilot holes (See Figure 1). Ensure the marks are in the
center of wood joists.
Figure 1
2. Drill 1/4" diameter pilot holes into wood stud cross bracing.
(See Figure 1) Ensure pilot holes are straight.
3. Install and tighten four 3/8" x 2-1/2" (minimum) Grade 2 lag
screws (not included) through CPA330 (A), into wood stud
cross bracing. (See Figure 2) (See Figure 3) for dimensions
details.
Figure 2
Figure 3
Installing to a Suspended Ceiling
NOTE:
The CPA mount may be suspended from four 3/8 in.
diameter ASTM A307 or better threaded rods (not
provided) which are secured to a 1-5/8" x 1-5/8" 12ga
metal framing strut channel (spanning a maximum of 4
feet--not provided) by ASTM A307 or better 3/8"
channel nuts (not provided). Threaded rods must have
16 threads per square inch.
1. Insert the rods into the four bolt holes in the CPA mount.
2. Secure the threaded rods to the CPA mount with ASTM
A307 or better 3/8" jam nuts (not provided) and washers
(one of each on inside and one of each on outside-not
provided). (See Figure 3) for dimensions details.
1
2
x 4
Cross bracing
3
x 4
(A)
CPA330 Installation Instructions
6
Installing to a Solid Concrete Ceiling Structure
WARNING: The CPA330 is designed to be mounted to a
concrete ceiling with a minimum thickness of 8".
WARNING: Fischer UX10 anchors (not provided) must be
installed into structurally sound solid concrete. Installation
into hollow concrete block, mortar, or concrete that exhibits
cracking, spalling, or other defects may result in failure of
anchor and serious personal injury or damage to equipment.
1. Use four UX10 anchors (not provided) to secure CPA mount
into solid concrete ceiling. (See Figure 3) for dimensions
details.
2. Place CPA mount over anchors, aligning bolt holes in CPA
mount with installed anchors.
3. Secure CPA mount to ceiling using four 3/8" Grade 2 flat
washers (not provided) and four 3/8" x 2 1/2" Grade 2 bolts
(not provided) tightened over anchors.
Installing Extension Column
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components located within the mounting system of the
CPA330 does not exceed 500 lbs (226.8 kg).
1. Route cables through extension column (not included).
2. Install
UL Listed CPA Extension Column Series (not
included) into CPA330.
NOTE: Installation of hex head self-tapping screws will be
easier when screws are carefully aligned with holes in
extension column, and a drill and nut driver is used. If
a drill will NOT be used, a small amount of pressure will
be needed to get the self-tapping screws started.
3. Secure extension column to CPA330 using four 5/16-18 x 1"
hex head self-tapping screws (B), four 5/16" split lock
washers (C) and four 5/16" flat washers (D) through holes
in extension column. (See Figure 4)
4. Install one 5/16" x 1/2" set screw (E) into threaded hole,
tightening firmly against column.
Figure 4
5. Complete installation following mount installation
instructions.
2
3
Extension column
(not included)
4
(E) x 1
(B) x 4
(C) x 4
(D) x 4
Installation Instructions CPA330
7
CPA330 Installation Instructions
USA/International A 6436 City West Parkway, Eden Prairie, MN 55344
P 800.582.6480 / 952.225.6000
F 877.894.6918 / 952.894.6918
Europe A Franklinstraat 14, 6003 DK Weert, Netherlands
P +31 (0) 495 580 852
F +31 (0) 495 580 845
Asia Pacific A Office No. 1 on 12/F, Shatin Galleria
18-24 Shan Mei Street
Fotan, Shatin, Hong Kong
P 852 2145 4099
F 852 2145 4477
Chief Manufacturing, a products division
of Milestone AV Technologies
8800-002252 Rev00
2012 Milestone AV Technologies, a
Duchossois Group Company
www.chiefmfg.com
11/12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Chief CPA330 Guide d'installation

Catégorie
Accessoires pour projecteurs
Taper
Guide d'installation

dans d''autres langues