Becker Centronic UnitControl UC45 Operating Instructions Manual

Taper
Operating Instructions Manual

Ce manuel convient également à

MM
C
N
Ind.
Zentral
Zentral
Ind.
L
N
L
N
4031 200 011 0
Centronic UnitControl UC45
Imax 5A
230V/50Hz/4VA
Centronic UnitControl UC42/UC45
Bedienungsanleitung
Operating Instructions
Notice d utilisation
Gebruiksaanwijzing
DE
GB
FR
NL
4031 200 010 0
Centronic UnitControl UC42
Ind.
Ind.
N
L
L
C
M
M
LN
230V / 50Hz / 4VA
Zentral
Zentral
Imax 5A
Wichtige Informationen für den Elektroanschluss.
Important information about the electric supply connection.
Informations importantes pour le branchement électrique.
Belangrijke informaties voor de elektrische aansluitingen.
Einzelsteuergerät UC42
Einzelsteuergerät
für Hutschiene UC45
Individual Controller UC42
Individual Controller
for Top-Hat Rail UC45
Commande individuelle UC42
Commande individuelle
pour rail UC45
Elektronische
relaisbesturing UC 42
Elektronische relaisbesturing
voor montage op DIN-rail UC45
2
Inhaltsverzeichnis
Contents
Gewährleistung ............................................................................................. 4
Sicherheitshinweise ...................................................................................... 4
Bestimmungsgemäße Verwendung ................................................................ 5
Montage UC42 .............................................................................................. 5
Montage UC45 .............................................................................................. 5
Funktion ....................................................................................................... 5
Anschlussplan UC42 / UC45 .......................................................................... 6
Anschlussbeispiel UC42 ................................................................................ 7
Anschlussbeispiel UC45 ................................................................................ 8
Technische Daten ......................................................................................... 9
Warranty ..................................................................................................... 10
Safety instructions ...................................................................................... 10
Designated use ........................................................................................... 11
Installation UC42 ......................................................................................... 11
Installation UC45 ......................................................................................... 11
Function ..................................................................................................... 11
Connection plan UC42 / UC45 ..................................................................... 12
Connection example for UC42 ..................................................................... 13
Connection example for UC45 ..................................................................... 14
Technical Data ............................................................................................ 15
3
Sommaire
Inhoudsopgave
Prestation de Garantie ................................................................................. 16
Consignes de sécurité ................................................................................. 16
Utilisation conforme aux prescriptions .......................................................... 17
Montage UC42 ............................................................................................ 17
Montage UC45 ............................................................................................ 17
Fonctionnement .......................................................................................... 17
Exemple de branchement UC42 / UC45........................................................ 18
Exemple de branchement UC42 ................................................................... 19
Exemple de branchement UC45 ................................................................... 20
Caractéristiques techniques ........................................................................ 21
Garantieverlening........................................................................................ 22
Veiligheidsinstructies .................................................................................. 22
Reglementair gebruik .................................................................................. 23
Montage UC42 ............................................................................................ 23
Montage UC45 ............................................................................................ 23
Functie ....................................................................................................... 23
Voorbeeld aansluiting UC42 / UC45 ............................................................. 24
Voorbeeld aansluiting UC42......................................................................... 25
Voorbeeld aansluiting UC45......................................................................... 26
Technische gegevens .................................................................................. 27
Bedienungsanleitung
4
Inhaltsverzeichnis
Becker-Antriebe GmbH ist von der gesetzlichen und vertraglichen Gewährleis-
tung für Sachmängel und Produkthaftung befreit, wenn ohne unsere vorherige
Zustimmung eigene bauliche Veränderungen und/oder unsachgemäße Installati-
onen gegen unsere vorgegebenen Montagerichtlinien vorgenommen, ausgeführt
oder veranlasst werden.
Der Weiterverarbeiter hat darauf zu achten, dass alle für die Herstellung und
Kundenberatung erforderlichen gesetzlichen und behördlichen Vorschriften,
insbesondere die EMV-Vorschriften, eingehalten werden.
Das vorliegende Produkt unterliegt technischen Weiterentwicklungen und Ver-
besserungen, informieren Sie sich in den aktuellen Verkaufsunterlagen über die
genauen Produktspezifikationen.
Gewährleistung
Sicherheitshinweise
Vorsicht
Bitte bewahren Sie die Anleitung auf!
Nur in trockenen Räumen verwenden.
Verwenden Sie nur unveränderte Becker Originalteile.
Halten Sie Personen aus dem Fahrbereich der Anlagen fern.
Halten Sie Kinder von Steuerungen fern.
Beachten Sie Ihre landesspezifischen Bestimmungen.
Gewährleistung ............................................................................................. 4
Sicherheitshinweise ...................................................................................... 4
Bestimmungsgemäße Verwendung ................................................................ 5
Montage UC42 .............................................................................................. 5
Montage UC45 .............................................................................................. 5
Funktion ....................................................................................................... 5
Anschlussplan UC42 / UC45 .......................................................................... 6
Anschlussbeispiel UC42 ................................................................................ 7
Anschlussbeispiel UC45 ................................................................................ 8
Technische Daten ......................................................................................... 9
Bedienungsanleitung
5
Bestimmungsgemäße Verwendung
Montage UC42
Die Centronic UnitControl UC42 und Centronic UnitControl UC45 sind vielseitig
verwendbare Relaissteuerungen. Sie dienen zum Ansteuern eines Rohrantriebs
mit mechanischer oder elektronischer Endabschaltung (ohne Funkempfänger),
sowie zur Ansteuerung von weiteren Folgesteuerungen. Durch die Möglichkeit
der Potentialfreischaltung der Ausgänge kann die UC42 auch zur Ansteuerung im
Niederspannungsbereich eingesetzt werden.
Der typische Einbau erfolgt in der Verteilerdose neben dem Antrieb. Die Montage
kann auch in einer tiefen Verteilerschalterdose (mit mindestens 60 mm voll-
flächiger Tiefe) hinter einem Auf/Ab Taster erfolgen. Die Verdrahtung erfolgt ge-
mäß Anschlußplan.
Montage UC45
Die UC45 wird innerhalb eines Kabelkanals mit integriertem Hutschienensystem
oder innerhalb eines Verteilerschranks montiert. Die Verdrahtung erfolgt gemäß
Anschlussplan.
Funktion
Der Individualbefehl erfolgt als Tippbefehl (Dauer des Befehls < 1 Sek.) oder als
Selbsthaltungsbefehl (Dauer des Befehls > 1 Sek.).
In Verbindung mit Jalousien werden Tippbefehle als Wendebefehle ausgeführt.
Der Individualbefehl wird durch einen handelsüblichen Serientaster ausgelöst.
Der Individualbefehl setzt einen Fahrbefehl von maximal 3 Minuten ab.
Der Zentralbefehl wird im Totmannbetrieb ausgeführt. Die Ansteuerung erfolgt
über vorgeschaltete Steuerungen wie Zeitschaltuhren, Sonnenwindautomaten
usw. Durch das Überordnen einer weiteren UC42/UC45 kann der Zentralbefehl in
Selbsthaltung ausgeführt werden. Auch das Bilden verschiedener Gruppen-
befehle ist durch das Überordnen weiterer UC42/UC45 beliebig möglich.
Eingehende Befehle werden in folgender Reihenfolge abgearbeitet:
1. Zentralbefehl AUF
2. Zentralbefehl AB
3. Individualbefehl AUF
4. Individualbefehl AB
Bedienungsanleitung
6
Anschlussplan UC42 / UC45
Zentral
Motor
Individual
Zentral
Individual
Individual
Zentral
UC45
Motor
UC42
L
N
PE
L
N
PE
Achtung
Niemals den Antrieb parallel zu den Eingängen der UC42/UC45 schalten!
Die Installation der Steuerung darf nur durch Fachpersonal erfolgen. Bei
Nichtbeachtung haftet der Hersteller oder Anbieter nicht für entstande-
ne Personen- oder Sachschäden, sowie für Folgeschäden.
Bedienungsanleitung
7
Anschlussbeispiel UC42
Individual Individual IndividualGruppe Zentral
NYM J
4x1,5mm
2
NYM J
4x1,5mm
2
NYM J
4x1,5mm
2
NYM J
5x1,5mm
2
NYM J
5x1,5mm
2
Netz
NYM J
3x1,5mm
2
NYM J
5x1,5mm
2
NYM J
5x1,5mm
2
NYM J
5x1,5mm
2
NYM J
5x1,5mm
2
Bedienungsanleitung
8
Anschlussbeispiel UC45
Individual
Individual
Individual
Gruppe
Zentral
Schaltschrank
Zentral
Gruppe
Individual
Zentralleitung
Gruppenleitung
Gruppe
Individual
Zentral
UC45
Motor
Individual
Zentral
UC45
Motor
Individual
Zentral
UC45
Motor
Individual
Zentral
UC45
Motor
L1
N
PE
L1
N
PE
L2
N
PE
Bedienungsanleitung
9
Technische Daten
CentronicCentronic
CentronicCentronic
Centronic
CentronicCentronic
CentronicCentronic
Centronic
UnitControl UC42UnitControl UC42
UnitControl UC42UnitControl UC42
UnitControl UC42
UnitControl UC45UnitControl UC45
UnitControl UC45UnitControl UC45
UnitControl UC45
Art.-Nr. 4031 000 003 0 4031 000 004 0
Gehäusemaße (B x H x T): 49 x 47 x 22 mm 36 x 95 x 58 mm
Schaltleistung: 5 A / 230 V AC ; 5 A / 30 V DC
Versorgungsspannung: 230 V / 50 Hz
Versorgungsstrom: 20 mA
Einsatzbereich: -40 °C ... +70 °C
Schutzart: IP30
Aufnahmeleistung: 4,6 VA
Technische Änderungen vorbehalten.
Operating Instructions
10
Contents
Becker-Antriebe GmbH will be released from all warranty and product liability ob-
ligations if the customer modifies the equipment without prior approval from
Becker-Antriebe GmbH or if the equipment is installed incorrectly and/or contrary
to the specified installation instructions, by the customer or a third party.
Any further processing must comply with all current statutory and official regula-
tions governing manufacture and advice to customers, especially the EMC regu-
lations.
This product is subject to technical developments and improvements. Please re-
fer to the current sales brochure for the precise product specifications.
Warranty
Safety instructions
Warning
Please keep these instructions in a safe place!
For use in dry rooms only.
Use unmodified Becker original parts only.
Keep persons away from the systems guide track.
Keep children away from controls.
Always comply with relevant national stipulations.
Warranty ..................................................................................................... 10
Safety instructions ...................................................................................... 10
Designated use ........................................................................................... 11
Installation UC42 ......................................................................................... 11
Installation UC45 ......................................................................................... 11
Function ..................................................................................................... 11
Connection plan UC42 / UC45 ..................................................................... 12
Connection example for UC42 ..................................................................... 13
Connection example for UC45 ..................................................................... 14
Technical Data ............................................................................................ 15
Operating Instructions
11
Designated use
Installation UC42
The Centronic UnitControl UC42 and Centronic UnitControl UC45 are relay con-
trols which can be used in a variety of applications. These controllers are used to
operate a tubular drive with mechanical or electronic limit switches (without radio
receiver), as well as to operate other sequential phase controls. The UC42 can
also be used in the low voltage range as the outputs can optionally be isolated.
(floating outputs)
The unit is generally installed in the junction box next to the drive. Alternatively, it
can also be installed in a deep distribution circuit-breaker box (with a depth of at
least 60 mm over its entire area) behind an Up/Down switch. Wiring is effected
according to the wiring diagram.
Installation UC45
The UC45 is to be mounted in a cable duct with an integrated top-hat rail system
or inside a distribution box. Wiring must be carried out in accordance with the ter-
minal diagram.
Function
The individual command is executed as a touch control command (duration of
command < 1 sec.) or as a self-locking command (duration of command > 1
sec.).
In conjunction with blinds, touch control commands are executed as reversing
commands. The individual command is triggered by a standard commercial serial
switch. The individual command operates in increments of 3 minutes running
time.
The central command is executed in dead man’s mode. Triggering occurs via
controls connected in series, such as programme timers, sun and wind units etc.
The connection of an additional superordinate UC42/UC45 controller allows the
central command to be executed in automatic mode. It is also possible to form
various groups by connecting further UC42/UC45 controllers.
Incoming commands are processed in the following order:
1. UP central command
2. DOWN central command
3. UP individual command
4. DOWN individual command
Operating Instructions
12
Connection plan UC42 / UC45
Central
Drive
Individual
Central
Individual
Individual
Central
UC45
Drive
UC42
L
N
PE
L
N
PE
Caution
The drive must NEVER be connected parallel to the UC42/UC45 inputs!
The control must be installed by qualified personnel. In the event of non-
observance, the manufacturer or supplier does not accept any liability
for possible personal injuries or damage to property that may arise, nor
for any consequential damages.
Operating Instructions
13
Connection example for UC42
Individual Individual IndividualGroup Central
NYM J
4x1,5mm
2
NYM J
4x1,5mm
2
NYM J
4x1,5mm
2
NYM J
5x1,5mm
2
NYM J
5x1,5mm
2
Mains
NYM J
3x1,5mm
2
NYM J
5x1,5mm
2
NYM J
5x1,5mm
2
NYM J
5x1,5mm
2
NYM J
5x1,5mm
2
Operating Instructions
14
Connection example for UC45
Individual
Individual
Individual
Group
Central
Electrical Enclosure
Central
Group
Individual
Central line
Group line
Group
Individual
Central
UC45
Drive
Individual
Central
UC45
Drive
Individual
Central
UC45
Drive
Individual
Central
UC45
Drive
L1
N
PE
L1
N
PE
L2
N
PE
Operating Instructions
15
Technical Data
CentronicCentronic
CentronicCentronic
Centronic
CentronicCentronic
CentronicCentronic
Centronic
UnitControl UC42UnitControl UC42
UnitControl UC42UnitControl UC42
UnitControl UC42
UnitControl UC45UnitControl UC45
UnitControl UC45UnitControl UC45
UnitControl UC45
Item no. 4031 000 003 0 4031 000 004 0
Housing dim. (WxHxD): 49 x 47 x 22 mm 36 x 95 x 58 mm
Rupturing capacity: 5 A / 230 V AC ; 5 A / 30 V DC
Supply voltage: 230 V / 50 Hz
Supply current: 20 mA
Operative range: -40 °C ... +70 °C
Protection type: IP30
Power input: 4,6 VA
Subject to technical changes without notice
Notice d utilisation
16
Sommaire
Becker-Antriebe GmbH est dégagé de la garantie et de la responsabilité du fait du
produit si, sans notre autorisation préalable, des modifications de construction
sont effectuées et/ou des installations inadéquates sont exécutées ou engagées,
à l'encontre de nos directives de montage prescrites.
L'utilisateur / l'électricien doit veiller à ce que toutes les consignes et prescrip-
tions en vigueur, particulièrement celles en matière de compatibilité électroma-
gnétique, soient respectées.
Le présent produit est soumis à des développements et perfectionnements tech-
niques, informez-vous dans les documents de vente actuels au sujet des spécifi-
cations de produit précises.
Prestation de Garantie
Consignes de sécurité
Prudence
Prière de conserver ces instructions d’utilisation!
A utiliser uniquement dans des locaux secs.
Utilisez uniquement des pièces originales de Becker n’ayant subi
aucune modification.
Veillez à ce que personne ne se tienne dans la zone de déploiement des
installations
Tenez les enfants à l’écart des commandes.
Observez les directives spécifiques de votre pays.
Prestation de Garantie ................................................................................. 16
Consignes de sécurité ................................................................................. 16
Utilisation conforme aux prescriptions .......................................................... 17
Montage UC42 ............................................................................................ 17
Montage UC45 ............................................................................................ 17
Fonctionnement .......................................................................................... 17
Exemple de branchement UC42 / UC45........................................................ 18
Exemple de branchement UC42 ................................................................... 19
Exemple de branchement UC45 ................................................................... 20
Caractéristiques techniques ........................................................................ 21
Notice d utilisation
17
Utilisation conforme aux prescriptions
Montage UC42
La Centronic UnitControl UC42 et la Centronic UnitControl UC45 sont des com-
mandes relais utilisables de façon multiple. Elles servent à commander un moteur
tubulaire avec fin de course mécanique ou électronique (sans récepteur radio),
ainsi qu’à commander d’autres commandes successives. Grâce à la possibilité
de libération de potentiel des sorties, la UC42 peut également être utilisée dans
une zone à basse tension.
Le montage typique est effectué dans le distributeur placé à côté du moteur. Il
peut également être réalisé dans un distributeur-commutateur profond (profon-
deur minimale sur toute la surface: 60 mm) derrière une touche MONTÉE/ DES-
CENTE. Le câblage s’effectue conformément au plan des connexions.
Montage UC45
La commande UC45 est montée à l’intérieur d’une conduite de câbles avec rail
intégré ou à l’intérieur d’une armoire électrique. Le câblage s’effectue conformé-
ment au plan de branchement.
Fonctionnement
La commande individuelle s’effectue comme commande tapée (durée < 1 sec., -
mouvement aller-retour du moteur) ou comme commande automatique (durée >
1 sec. - le moteur marche jusqu’à la position finale).
Combinées avec des volets roulants, les commandes tapées ont pour effet un
changement de direction du volet roulant. La commande individuelle est déclen-
chée par une inverseur sériel. La commande individuelle reste active pendant 3
minutes.
La commande centrale est effectuée en mode homme mort (la touche doit être
maintenue appuyée). Le contrôle des moteurs s’effectue par des appareils
comme par exemple des horloges ou des automatismes soleil et vent associés.
En plaçant au niveau supérieur une autre UC42/UC45, la commande centrale
peut être exécutée en position de maintien maintenue. La formation de différents
groupes est également possible en plaçant au niveau supérieur autant de UC42/
UC45 que l’on souhaite.
Exécution des commandes dans l’ordre suivant :
1. Commande centrale MONTEE
2. Commande centrale DESCENTE
3. Commande individuelle MONTEE
4. Commande individuelle DESCENTE
Notice d utilisation
18
Exemple de branchement UC42 / UC45
Central
Moteur
Individuelle
Central
Individuelle
Individuelle
Central
UC45
Moteur
UC42
L
N
PE
L
N
PE
Attention
Ne jamais brancher le moteur parallèlement aux entrées UC42/UC45 !
L’installation de la commande ne doit être réalisée que par du personnel
qualifié. En cas de non-respect, le fabricant ou le revendeur n’assument
aucune garantie pour les dommages corporels ou matériels, ainsi que
pour les dommages consécutifs.
Notice d utilisation
19
Exemple de branchement UC42
Individuelle Individuelle IndividuelleGroupe Centrale
NYM J
4x1,5mm
2
NYM J
4x1,5mm
2
NYM J
4x1,5mm
2
NYM J
5x1,5mm
2
NYM J
5x1,5mm
2
Réseau
NYM J
3x1,5mm
2
NYM J
5x1,5mm
2
NYM J
5x1,5mm
2
NYM J
5x1,5mm
2
NYM J
5x1,5mm
2
Notice d utilisation
20
Exemple de branchement UC45
Individuelle
Individuelle
Individuelle
Groupe
Centrale
Armoire électrique
Centrale
Groupe
Individuelle
Ligne centrale
Ligne de groupe
Groupe
Individuelle
Central
UC45
Moteur
Individuelle
Central
UC45
Moteur
Individuelle
Central
UC45
Moteur
Individuelle
Central
UC45
Moteur
L1
N
PE
L1
N
PE
L2
N
PE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Becker Centronic UnitControl UC45 Operating Instructions Manual

Taper
Operating Instructions Manual
Ce manuel convient également à