Do not remove the control knob bezel to
access hood wiring; this will damage the
bezel assembly.
Location of electrical box—wall hoods
IMPORTANT
NOTE
You must follow
all building and
electrical code
regulations. In
addition, be aware
of local codes and
ordinances when
installing your
service.
ELECTRICAL WIRING
This ventilation hood must be properly
grounded. This unit should be installed by
a qualified electrician in accordance with
all applicable local electrical codes.
Before servicing or cleaning unit, switch
power off at service panel and lock the
service disconnecting means to prevent
power from being switched on acciden-
tally. When the service disconnecting
means cannot be locked, securely fasten a
prominent warning device, such as a tag,
to the service panel.
Cord anchorage must be used at both ends
of the fixed wiring.
Remove the electrical box cover from the
back plate. Using the terminal block,
connect brown wire to power supply brown
wire, blue wire to power supply blue wire
and green/yellow striped wire to
green/yellow striped wire or bare wire.
Place all wiring connections inside the
electrical box and reinstall on the back plate
in the upper right-hand corner. Make sure
that the wires are secure and that no wires
are pinched between the cover and box.
Follow these instructions to install wiring for
all Wolf Pro wall hoods:
Run a circuit from the service panel to the
electric box on the back plate.
Maximum power requirements with motors:
220-240 V AC 50/60 Hz
2–6 Amps
0.46–1.37 kW
See unit rating label for specific power
requirements.
Wiring diagram for the unit is located on the
outside of the back panel.
Run the fixed wiring through the holes in the
back plate to the electrical box. Refer to the
illustration below for the location of the
electrical box.
IMPORTANT NOTE:
Connection of this appli-
ance should be through a fused connection
unit or a suitable isolator, which complies with
national and local safety regulations. The
on/off switch should be easily accessible after
the appliance has been installed. If the switch
is not accessible after installation (depending
on country) an additional means of disconnec-
tion must be provided for all poles of the
power supply. When switched off there must
be an all pole contact gap of 3 mm in the
isolator switch. This 3 mm contact disconnect
gap must apply to any isolator switch, fuses
and/or relays according to EN60335.
Electrical
Box
WOLF PRO VENTILATION HOODS
48 mm
89 mm
318 mm
Pro hood liner wiring location