IS-44336-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
4) Make wire connecon. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (see illus.)
Neutral Wire
5) Aach the inspecon cable[L] to the mounng strap
or to the inside of the mounng box. Push xture to
ceiling, carefully passing mounng screws through holes
in canopy[E]. NOTE: Be certain wires do not get pinched
between canopy and ceiling.
6) Use knobs[J] and lockwashers[K] to secure canopy.
Tighten to secure.
7) Raise the side glass panel[I] up to the side of the main
body and secure into place using four (4) screws[G] and
four (4) sloed nuts[H]. Repeat for the other panels.
8) Insert recommended bulbs(s) (Not supplied).
9) Raise the boom glass panel[F] up to the boom of the
main body and secure into place using four(4) screws[G]
and four(4) sloed nuts[H].
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
[A] Mounting
Stap
[B] Mounting
Screws
[C] Outlet Box
[D] Strap
Mounting
Screws
[E] Canopy
[F] Bottom Glass
Panel
[G] Screws
[H] Slotted Nuts
[I] Side Glass
Panels
[J] Knobs
[K] Lockwashers
[L] Inspection
Cable
1) Find the appropriate threaded holes on mounng
strap[A]. Assemble mounng screws[B] into threaded
holes.
2) Aach mounng strap to outlet box[C] using the
strap mounng screws[D]. The mounng strap can be
adjusted to suit posion of xture.
3) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, then thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector aer following the above steps. Never connect
ground wire to black or white power supply wires.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
C
A
D
B
E
J
K
G
F
H
I
L
Installaon Instrucons (connued)