Tetra GELTD2471-1E Series LED Lighting System Guide d'installation

Taper
Guide d'installation
Tetra® LT
LED Lighting System
Installation Guide
SIGN294 | DOC-2001487
GELTS2471-1
GELTS2465-1
GELTS2450-1
GELTS2441-1
GELTM2471-1
GELTM2465-1
GELTM2450-1
GELTM2441-1
GELTD2471-1
GELTD2465-1
GELTD2450-1
GELTD2441-1
GELTD2471-1E
GELTD2465-1E
GELTD2450-1E
GELTD2441-1E
RETROFIT SIGN CONVERSION LED KIT FOR USE ONLY IN
ACCORDANCE WITH KIT INSTRUCTIONS.
KIT IS COMPLETE ONLY WHEN ALL PARTS REQUIRED BY
THE INSTRUCTIONS ARE PRESENT.
TROUSSE DE CONVERSION À DEL POUR LA
MODERNISATION DES ENSEIGNES
À UTILISER CONFORMÉMENT AU GUIDE D’INSTALLATION.
Electrical Requirements
Acceptable for use in dry, damp and wet locations.
The grounding and bonding of the LED Driver shall be done
in accordance with National Electric Code (NEC) Article 600.
Follow all National Electric Codes (NEC) and local codes.
These products are only suitable for connection to a circuit
from a Class 2 power source.
These products have not been evaluated for use when
connected to a power source that does not comply with
Class 2 voltage and energy limited supplies.
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
FOR UL ONLY
For the latest North American install guides for your product go to: https://products.gecurrent.com/sign-lighting/tetra-max
For the latest European install guides for your product go to: https://products.gecurrent.com/eu
BG Българската версия на инструкциите за инсталаця и
информация за безопасност могат да бъдат намерени
на следния адрес: https://products.gecurrent.com/eu
CS Návod k montáží a bezpečnostní informace v češtině
najdete zde: https://products.gecurrent.com/eu
DA Den danske version af installationsvejledningen og
sikkerhedsoplysninger kan ndes på følgende placering:
https://products.gecurrent.com/eu
DE Die deutsche Version der Installationsanleitung und
Sicherheitsinformationen nden Sie in folgendem Verzeic:
https://products.gecurrent.com/eu
EL Μπορείτε να βρείτε την ελληνική εκδχή των οδηγιών
νγκατάστασης και των πληροφοριών ασφάλειας στην
εξής τοποθεσία: https://products.gecurrent.com/eu
ES La versión española de las instrucciones de instalación y
la información sobre seguridad puede encontrarse en la
siguiente ubicación: https://products.gecurrent.com/eu
ET Eestikeelse paigaldusjuhendi ja ohutusnñuded leiate
aadressilt: https://products.gecurrent.com/eu
FI Asennusohjeiden ja turvallisuustietojen suomenkielinen
versio löytyy seuraavasta paikasta: https://products.
gecurrent.com/eu
FR La version française des instructions d’installations
et information de sécurité est disponible à l’adresse
suivante: https://products.gecurrent.com/eu
HR Hrvatska verzija priručnika za ugradnju i sigurnosnih
informacija nalazi se na sljedečoj lokaciji: https://products.
gecurrent.com/eu
HU A telepítési útmutató és a biztnosági információk magyar
nyelvű változata az alábbi címen található: https://
products.gecurrent.com/eu
IT La versione italiana del manuale di installazione e
sicurezza può essere reperita nella seguente sezione:
https://products.gecurrent.com/eu
LT Lietuvišką diegimo instrukcijos ir saugos informacijos
versiją galima rasti šioje vietoje: https://products.
gecurrent.com/eu
LV Uzstādīšanas instrukciju un drošības informāciju latviešu
valodā var atrast šeit: https://products.gecurrent.com/eu
NL De Nederlandse versie van de installatie-instructies en
veiligheidsinformatie kan op de volgende locatie worden
gevonden: https://products.gecurrent.com/eu
PL Polską wersję instrukcji instalacji oraz informacje
dotyczące bezpieczeństwa można znaleźć w następującej
lokalizacji: https://products.gecurrent.com/eu
PT A versão em Português das instruções de instalação e
das informações de segurança pode ser encontrada na
seguinte localização: https://products.gecurrent.com/eu
RO Versiunea în limba română a instrucţiunilor de instalare
şi a informaţiilor de siguranţă pot  găsite la: https://
products.gecurrent.com/eu
SV Ni hittar den svenska versionen av
installationsanvisningarna och säkerhetsinformationen på
följande plats: https://products.gecurrent.com/eu
SL Previdnostna opozorila in varnostne informacije so na
zadnji strani vodnika za namestitev. Pred začetkom
namestitve izdelka jih skrbno preberite: https://products.
gecurrent.com/eu
SK Slovenskú verziu montažnej príručky a bezpečnostnŷch
instrukcií nájdete na nasledujúcej lokalite: https://
products.gecurrent.com/eu
BEFORE YOU BEGIN
Read these instructions completely and carefully.
2424
Volt
EN
Prepare Electrical Wiring
2
Tetra® LT Installation Guide
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
This product is intended solely for sign use only. Not intended for general lighting applications.
Conforms to the following standards: IP66
Electrical products must not be thrown out with domestic waste. They
must be taken to a communal collecting point for environmentally
friendly disposal in accordance with local regulations. Contact your
local authorities or stockist for advice on recycling. The packaging
material is recyclable. Dispose of the packaging in an environmentally
friendly manner and make it available for the recyclable material
collection-service.
III
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Turn power o before inspection, installation or removal.
Properly ground power supply enclosure.
RISK OF FIRE
Use only suitably approved wire for input/output
connections. Minimum size 18 AWG (0.82mm2)
Follow all local codes.
Not to be submerged or used in a marine environment.
RISQUES DE DÉCHARGES ÉLECTRIQUES
Coupez l’alimentation avant l’inspection, l’installation ou le déplacement.
Assurez-vous de correctement mettre à terre l’alimentation électrique.
RISQUES D’INCENDIE
N’utilisez que des ls approuvés par UL pour les entrées/sorties de connexion. Taille
minimum 18 AWG (0.82mm2)
Respectez tous les codes locaux.
Ne pas submerger ou installer dans un environnement marin.
UL WARNING / AVERTISSEMENT UL
RISK OF FIRE OR ELECTRIC SHOCK
LED Retrot Kit installation requires knowledge of
sign electrical systems. If not qualied, do not attempt
installation. Contact a qualied electrician.
Install this kit only in host signs that have been identied in
the installation instructions and where the input rating of
the retrot kit does not exceed the input rating of the sign.
Installation of this LED retrot kit may involve drilling or
punching of holes into the structure of the sign. Check
for enclosed wiring and components to avoid damage to
wiring and electrical parts.
Do not make or alter any open holes in an enclosure of
wiring or electrical components during kit installation.
RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE
L’installation de l’équipement de remplacement DEL exige Ia connaissance des
systèmes électriques pour enseignes. Si non qualié, ne tentez pas d’installation.
Veuillez contacter un électricien qualié.
Risque d’incendie ou de choc électrique. Installez cet ensemble seulement dans des
enseignes hôtes qui ont été identiés dans les instructions d’installation et dont la
capacité d’entrée de l’ensemble ne dépasse pas la capacité d’entrée de l’enseigne.
L’installation de cet équipement de remplacement DEL peut impliquer le perçage ou le
poinçonnage de trous dans la structure du panneau Vériez le câblage et les composants
inclus pour éviter d’endommager le câblage et les composants électriques.
Ne pas faire ou modier les trous ouverts dans une enceinte de câblage ou de
composants électriques pendant l’installation de cet équipement de remplacement DEL.
3
Tetra® LT Installation Guide
UL approved 18 AWG (0.82 mm2) supply wire
UL approved 22-14 AWG (0.33-2.08 mm2) wire connectors or
22-18 AWG (0.33-0.82 mm2) in-line/IDC connectors
#6 (M3) screws, 1/8 inch (3.2 mm) rivets, or electrical grade RTV
silicone or equivalent
Weather box GEXNWB2 (optional)
24 Volt Power Supply
Tetra® LT LED modules
Electrical grade RTV silicone:
Momentive RTV 6700 Series Silicone Rubber Adhesive Sealant
Momentive White Blanc RTV 162 Silicone Rubber Adhesive
Sealant-Electrical Grade
Dow Corning 3140 - Non-Corrosive Flowable (clear)
Dow Corning 3145 - Non-Corrosive Nonowable (clear or gray)
Dow Corning RTV 748 Non-Corrosive Sealant-White
Components
1234
5
6
7
1
2
3
4
5
6
7
Components - Tetra® SNAP Accessories (optional)
Tetra SNAP Rail (GEDSRL08-3)
Tetra Snap SS Metal Clip (GESSMC-3)
Tetra SNAP Frame Endcap (GEDSFE-3)
Tetra SNAP Socket Endcap (GEDSSE-3)
Tetra SNAP Dual Rail Socket Cap (GESSDR-3)
Tetra SNAP T-connector (GEDSTC-3)
Tetra SNAP Interconnector (GEDSIC-3)
Tetra® LT is also compatible with the following Tetra SNAP Rail components.
See https://products.gecurrent.com/led-signage-lighting for further details and install instructions.
1
12
2
3
3
4
4
5
56
6
7
7
TC Measure Point TC Measure Point
4
Tetra® LT Installation Guide
Measure and cut Tetra LED strip
to the appropriate length for
each letter. Cuts can be made
between any of the modules.
Remove tape backing and stick
LED modules into place. When
using tape apply approximately
15 psi pressure on the module
(avoid the lens dome surface) for
5 seconds, full bonding strength
after 24 hours. Continue until you
have reached the end of the strip.
Use rivets, screws, or electrical
grade RTV silicone to secure
at least every fth LED module
within the channel letter. Use #6
(M3) pan headed metal screws,
1/8-inch (3.2 mm) rivets, or
electrical grade RTV silicone.
NOTE: Modules may be damaged
by improperly sized screws or
over-torquing
Before you begin, clean surfaces
and remove all debris from the
inside of the channel letter. Clean
the surfaces with a 50:50 mixture
of isopropyl alcohol (IPA) and
water and let dry.
Layout Modules
Drill a 1/4-inch (6.4 mm) hole
near the LED strip and grommet
the hole for supply wire access.
Remove all the debris from the
inside of the channel letter and
replace the sign face.
NOTE: For halo-lit applications LED modules should be mounted on UL
recognized clear acrylic or polycarbonate. The light output from the LED
system should be directed back into the sign enclosure. This will allow for
uniform backlighting of the sign and will provide simple mounting.
Do not
press lens
Connect LED strips using in-line (IDC) connectors or
twist-on wire connectors.
NOTE: Seal all connections in wet locations with
electrical grade RTV silicone.
Must cap all exposed wires with appropriate wire
connectors and seal with electrical grade RTV silicone.
Optional: Cut wires ush to the module and seal with
electrical grade RTV silicone.
Electrical Connections
NOTE: Do not use connectors pre-lled with silicone grease/mineral base protective grease or use silicone grease to seal connections.
Red stripe (+)
White (-)
Cap wires Optional: Cut wires ush
Seal all connections in wet locations
with electrical grade RTV silicone
1
4
1 2
2
5
3
6
5
Tetra® LT Installation Guide
To LED
power
supply
Red (+)
Black or
blue (-)
Red Stripe (+)
Run a wire from the LED power supply to the LED
module and connect.
NOTE: Must be used with a 24 Volt Power Supply.
NOTE: Refer to Maximum Loading & Remote
Mounting Specications on last page.
Connect the red stripe wire (+) of the LED strip to the
red wire (+) of the power supply. Connect the white
wire (-) of the LED strip to the black or blue wire (-) of
the LED power supply.
NOTE: All electrical connections should be suitably
protected from mechanical damage and the
environment. Seal all connections in wet locations with
electrical grade RTV silicone.
LED
Power
Supply
To Tetra LED System
Red (+)
Black or blue (-)
White (-)
Seal all connections in wet locations
with electrical grade RTV silicone
Retrot Instructions
1. (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the
building. Ensure that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED
power supply, and have a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes
(whichever is less).
2. (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or uorescent tubes; and associated
transformers and ballasts. Care should be taken not to break the existing neon or uorescent tubes. NOTE: Follow all federal and local
regulations when disposing of neon tubing, uorescent tubes, transformers and ballasts.
3. (Existing Signs Only) If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable local,
state, or country electrical codes; a new disconnect switch must be installed.
4. (Existing Signs Only) Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm (1/2-in) diameter
require a metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed with non-
hardening caulk.
5. (Existing Signs Only) A clean and dry mounting surface ensures optimum adhesion if the self-adhesive method of mounting is chosen.
Follow the manufacturer’s directions when using a non-oil based solvent, such as rubbing alcohol to clean the surface area where you
intend to mount the module. Before installing, ensure the surface is dry.
6. Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
7. A 24VDC Class 2 Power Supply, as listed below, must be used with this retrot kit. Using the Maximum Loading chart below, determine the
number of Power Supplies required to power the number of LED modules required to illuminate the sign, so as not to overload the Power
Supply chosen.
8. Follow the instructions above to properly mount the LED modules.
9. Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.
10. Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions found
in the power supply installation guide.
11. If required, the disconnect switch shall be installed by qualied personnel, in accordance with applicable local, state, and country electrical
codes.
FOR UL ONLY
OPTIONAL
A Weather Box (GEXNWB2) may be used to
house and seal Class 2 connections.
A) Insert wire connectors into weather box. Fill
with electrical grade silicone and close box.
B) Secure the weather box using a #6 or #8
(M2 or M3) screw.
Weather box
can be painted
3 4
A B
6
Tetra® LT Installation Guide
For optimal light uniformity in halo-lit applications the Tetra® LED modules should be mounted on UL recognized plastic and the light
output from the Tetra® LED system should be directed back into the sign enclosure. This will allow for uniform backlighting of the sign
and will provide simple mounting for the Tetra® LED system.
A best practice for the supply wire at the point at which it is brought into the sign is to have a drip loop on the inside of the letter to
keep water from collecting on the Tetra® LED strip.
At the end of life, the contained LED light source may be cut out using suitable wire cutters, removed from the mounting surface,
then replaced per the cutting and installation instructions above, or dismantled and taken to a communal collecting point for
environmentally friendly disposal in accordance with local regulations by a professional installer.
Symptom Solution
All letters are OFF Check AC input connection and/or check circuit breaker.
Check wire connection(s) at the Tetra® LED System and power supply for improper termination(s) or short
circuits. Properly terminate or replace the wire connection(s).
Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the power supply
and the white wire (-) of the LED strip to the black or blue wire (-) of the power supply.
Some LEDs
appear dim
Ensure the overall length of the Tetra® LED System does not exceed the maximum load.
Ensure the length of supply wire is equal to or below the recommended remote mounting distance.
Ensure the overall length of the Tetra® LED System does not exceed the maximum load.
Some of the letters are
not illuminated
Check wire connection(s) at the Tetra® LED System and power supply for improper termination(s) or short
circuits. Properly terminate or replace the wire connection(s).
Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the power
supply and the white wire (-) of the LED strip to the black or blue wire (-) of the power supply.
Shadows Re-route supply wire and secure to the back of the can with electrical grade RTV silicone. Adjust wire connector
orientation so that it does not cover any LEDs.
Adjust LED layout to ensure uniformity of illumination on the face of the letter.
Tips
Dismantling
Troubleshooting
Tetra® LT Installation Guide
www.gecurrent.com
© 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information provided is subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
SIGN294 (Rev 11/19/21) DOC-2001487
Maximum Loading per Tetra 24V DC Power Supply
Power Supply
GELTS2471-1
GELTS2465-1
GELTS2450-1
GELTS2441-1
GELTM2471-1
GELTM2465-1
GELTM2450-1
GELTM2441-1
GELTD2471-1
GELTD2465-1
GELTD2450-1
GELTD2441-1
GELTD2471-1E
GELTD2465-1E
GELTD2450-1E
GELTD2441-1E
Rating per module 24V DC
15mA/module
0.36W/module
24V DC
30mA/module
0.72W/module
24V DC
45mA/module
1.08W/module
24V DC
45mA/module
1.08W/module
GEPS24-25-NA
GEPS24-25-EU (CE only)
Load shall not exceed 1.04A
62 modules/
31 ft. (9.45 m) 31 modules/
19.4 ft. (5.9 m) 20 modules/
14.3 ft. (4.36 m) 20 modules/
20 ft. (6.10 m)
GEPS24D-80U
Load shall not exceed 3.3A
200 modules/
100 ft. (30.48 m) 100 modules/
62.5 ft. (19.05 m) 66 modules/
47.1 ft. (14.36 m) 66 modules/
66 ft. (20.12 m)
GEPS24-100U-GLX
USVI-100024FE
USVI-100024FBA
Load shall not exceed 4.0A
230 modules/
115 ft. (35.05 m) 114 modules/
71.3 ft. (21.71 m) 76 modules/
54.3 ft. (16.54 m) 76 modules/
76 ft. (23.16 m)
GEPS24-100U-GLX2
GEPS24-100U-TT
Load shall not exceed 4.0A
240 modules/
120 ft. (36.58 m) 120 modules/
75 ft. (22.86 m) 80 modules/
57.1 ft. (17.41 m) 80 modules/
80 ft. (24.38 m)
GEPS24-200U-GLX2
Load shall not exceed 4.0A per
each (of 2) output channels
240 modules/
120 ft. (36.58 m) per bank
480 modules/
240 ft. (73.15 m) per PS
120 modules/
75 ft. (22.86 m) per bank
240 modules/
150 ft. (45.72 m) per PS
80 modules/
57.1 ft. (17.41 m) per bank
160 modules/
114.3 ft. (34.83 m) per PS
80 modules/
80 ft. (24.38 m) per bank
160 modules/
160 ft. (48.76 m) per PS
GEPS24-300U-GLX2
Load shall not exceed 4.0A per
each (of 3) output channels
240 modules/
120 ft. (36.58 m) per bank
720 modules/
360 ft. (109.73 m) per PS
120 modules/
75 ft. (22.86 m) per bank
360 modules/
225 ft. (68.58 m) per PS
80 modules/
57.1 ft. (17.41 m) per bank
240 modules/
171.4 ft. (52.24 m) per PS
80 modules/
80 ft. (24.38 m) per bank
240 modules/
240 ft. (73.15 m) per PS
18 AWG/0.82 mm2
Supply Wire 16 AWG/1.31 mm2
Supply Wire 14 AWG/2.08 mm2
Supply Wire 12 AWG/3.31 mm2
Supply Wire
25W Power Supply 120 ft./36.6 m - - -
80W Power Supply 20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
100W Power Supply 20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
180W Power Supply 20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
200W Power Supply 20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
300W Power Supply 20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
Maximum Remote Mounting Distance from Driver Output
NOTE: The maximum loading claimed in the table is at ambient temperature 25°C (77°F).
For linear long runs, center connection to the LED strip is recommended to minimize voltage drop.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Tetra GELTD2471-1E Series LED Lighting System Guide d'installation

Taper
Guide d'installation