Samsung NK36R5000WG/AA Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur
Range Hood
Hotte de la cuisine
Campana de cocina
Installation Instructions Guide
Guide d’instructions d’installation
Guía de Instrucciones para Instalación
NK36R5000WG/AA, NK30R5000WG/AA
NK36R5000WS/AA, NK30R5000WS/AA
LIB0154965
2 English
Important Safety Instructions 3
Installation Requirements 4
Electrical Requirements 4
Before Installing the Hood 4
Venting Methods 4
Tools and Parts 5
Dimensions and Clearances 5
Installation 6
Installation Instructions 6
Install the Range Hood 7
Install Duct Covers 8
Electrical Connection 8
Range Hood Use and Care 9
Description of the Hood 9
Control 9
Maintenance 9
Accessories 10
Range Hood for ADA Compliance 11
Warranty (USA) 12
Warranty (Canada) 13
Table of Contents
Table of Contents
English 3
APPROVED FOR RESIDENTIAL APPLIANCES
FOR RESIDENTIAL USE ONLY
READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ENTIRE INSTALLATION GUIDE BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical
Inspector’s use.
INSTALLER: Please leave these Instructions with this unit for
the owner.
OWNER: Please retain these instructions for future
reference.
Symbols used in this manual
WARNING
Hazards or unsafe practices that may result in severe personal injury or
death.
CAUTION
Hazards or unsafe practices that may result in electric shock, personal
injury, or property damage.
NOTE
Useful tips and instructions
These warning icons and symbols are here to prevent injury to you and
others.
Please follow them explicitly. After reading this section, keep it in a safe
place for future reference.
WARNING
Turn off the power circuit at the service panel and lock
out panel before wiring this appliance.
Requirement 120 VAC, 60 Hz. 15 or 20 A Branch Circuit
WARNING
Cancer and Reproductive Harm - www.P65Warnings.ca.gov
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING PRECAUTIONS:
Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer.
Before servicing or cleaning the unit, switch the power off at the
service panel and lock the service panel to prevent power from being
switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such
as a tag to the service panel.
Installation work and electrical wiring must be done by qualied
person(s) in accordance with all applicable codes and standards,
including re-rated construction.
Sufcient air is needed for proper combustion and exhausting of
gases through the ue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), the American Society
for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE),
and the local code authorities.
Important Safety Instructions
Important Safety Instructions
When cutting or drilling into the wall or ceiling; do not damage
electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
CAUTION
To reduce the risk of re and to properly exhaust air, be sure to duct air
outside - do not vent exhaust air into spaces within walls or ceilings, or
into attics, crawl spaces or garages.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
WARNING
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils slowly
on low or medium settings.
Always turn the hood ON when cooking at high heat or when ambeing
food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
Clean ventilating fans frequently. Grease should not be allowed to
accumulate on the fan or lter.
Use proper pan sizes. Always use cookware appropriate for the size
of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF
A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING
PRECAUTIONS:
a
SMOTHER FLAMES with a close tting lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
If the ames do not go out immediately, EVACUATE AND CALL THE
FIRE DEPARTMENT.
NEVER PICK UP A FLAMING PAN - you may be burned.
DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result
Use an extinguisher ONLY if:
- You know you have a class ABC extinguisher, and you already know
how to operate it.
– The re is small and contained in the area where it started.
– The re department is being called.
– You can ght the re with your back to an exit.
a
Based on “Kitchen Fire Safety Tips” published by NFPA.
WARNING
To reduce the risk of re or electrical shock, do not use this fan with any
solid-state speed control device.
WARNING
Do not let children near this appliance. Do not let children play with this
appliance.
Keep all packaging materials out of children’s reach. Properly dispose the
packaging materials after this appliance is unpacked.
NOTE
Suitable for use in household cooking area.
Read and save this instructions
4 English
Installation Requirements
Electrical Requirements
IMPORTANT
Observe all governing codes and ordinances.
It is the customer’s responsibility:
To contact a qualied electrical installer.
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70
— latest edition*, or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all
local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended
that a qualied electrician determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Other Requirements
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
If the house has aluminum wiring, follow the procedure below:
1. Connect a section of solid copper wire to the pigtail leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors and/or tools designed
and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer’s recommended
procedure. Aluminum/copper connections must conform with local
codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of the
appliance as specied on the model/serial rating plate. The model
serial plate is located behind the lter on the rear wall of the range hood.
Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards
C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No.
0-M91 (latest edition) and all local codes and ordinances.
A U.L.- or C.S.A.-listed conduit connector must be provided at each
end of the power supply conduit (at the range hood and at the
junction box).
Before installing the Hood
The Vent system must terminate outdoors.
For the most efcient air ow exhaust, use a straight run or as few
elbows as possible. CAUTION: Vent unit to outside of building, only.
At least two people are necessary for installation.
Fittings material are provided to secure the hood to most types of
walls and ceilings. Consult a qualied installer to conrm that
the ttings are suitable for your cabinets, walls, and ceiling.
Do not use exible ducting.
COLD WEATHER installations should have an additional backdraft
damper installed to minimize backward cold air ow and a
nonmetallic thermal break to minimize conduction of outside
temperatures as part of the ductwork. The damper should be on the
cold air side of the thermal break. The break should be as close as
possible to where the ducting enters the heated portion of the house.
Venting Methods
Closely follow the instructions set out in this manual. Samsung is not
responsible for any eventual inconveniences, damages or res caused by
not complying with the instructions in this manual.
Ducting version
The hood is equipped with a 6” (15.2 cm) round transition for discharge of
fumes to the outside.
Horizontal Discharge Vertical Discharge Horizontal Discharge
A
B
A
B
A
B
A. Wall cap
B. 6” (15.2 cm) round vent
A. Roof cap
B. 6” (15.2 cm) round vent
A. Deector
B. 6” (15.2 cm) round vent
Preparation
Do not cut a joist or stud unless absolutely necessary. If a joist or stud
must be cut, then a supporting frame must be constructed.
Fittings material are provided to secure the hood to most types of walls/
ceilings.
However, a qualied technician must verify that the ttings are suitable
for your cabinets, walls, and ceiling.
Before making cutouts, make sure there is proper clearance within the
ceiling or wall for the exhaust vent.
Ductless version (Recirculating)
For installations where cooking fumes and vapor cannot be discharged
to the outside, attach a charcoal lter and the deector on the duct cover
support bracket. Fumes and vapors will be recycled through the top grille
by a duct connected to the transition and the transition mounted on the
deector.
NOTE
For horizontal discharge only: purchase the Ductless Recirculating Kit.
Minimum Duct Size: 6” Round Pipe.
CAUTION
For electric/induction cooktop & range installations: Mount the hood
so the bottom is at least 24” (61cm) above the cooking surface.
For gas cooktop & range installations: Mount the hood so the bottom
is at least 27” (68.6 cm) above the cooking surface.
For both, mount no higher than 36” (91.4 cm) above the cooking
surface.
Measure the mounting height from the surface of the range to the
bottom of the hood.
WARNING
This hood is intended for household use.
PLEASE READ THE INSTALLATION MANUAL FOR THE HOOD´S
SPECIFIC APPLICATION. Check your ceiling height and the hood´s
height before selecting your hood.
Installation Requirements
English 5
Tools and Parts
Removing the packaging
CAUTION
Remove the carton carefully. Wear gloves to protect against sharp edges.
WARNING
Remove the protective lm covering the product before putting it into
operation.
Parts supplied
Hood assembly with blower and LED lamps already installed.
Hardware bag with:
Part Qty Part Qty
5x45 mm
6
8x40 mm
2
5.4x75 mm
4
10x60 mm
4
3.5x9.5 mm
2
Duct cover bracket
1
2.9x6.5 mm
2
Mounting template
1
Duct Covers
2
6” round transition
1
Tools/Materials required
Level
Drill with 1¼” (3.2 cm),
1
8” (3.2 mm), and
1
16” (4.8 mm) drill bits
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Jigsaw or keyhole saw
Metal snips
Screwdrivers:
Phillips
Flat - blade
Parts needed
Home power supply cable
½” (12.7 mm) UL listed or CSA approved strain relief
3 UL listed wire connectors
1 wall or roof cap
Metal vent system
Optional accessories and consumable parts
MODEL
NK30R5000WS
NK36R5000WS
NK30R5000WG
NK36R5000WG
Extension Kit NK-AE505PWS/AA NK-AE505PWG/AA
Recirculating
Kit
NK-AF020FNB/AA
Charcoal
Filter
NK-AR040FNB/AA
* Order the needed kit specifying your hood model.
Dimensions and Clearances
A
B
D
C
G
F
E
NK30R5000WS
NK36R5000WS
NK30R5000WG
NK36R5000WG
A 30” (76.2 cm) 36″ (91.2 cm)
B 19
11
16″ (50 cm)
C*
Max: 42
1
8″ (107 cm)
Min: 28
6
16″ (72 cm)
D**
Max: 38
3
16″ (97 cm)
Min: 28
6
16″ (72 cm)
E 6” (15.24 cm)
F 7
3
16″ (18.3 cm)
G 8
3
16″ (20.8 cm)
* Ductless (Recirculating) version
** Ducted version
Installation Requirements
Installation Requirements
6 English
Installation Instructions
We recommend that a qualied technician install the range hood. It is the
installer’s responsibility to ensure the range hood complies with the instal-
lation clearances speciations for the product.
It is recommended that the vent system be installed before the hood is
installed.
Before making cutouts, make sure there is proper clearance within the
ceiling or wall for the exhaust vent.
Conrm that all installations parts have been removed from the
shipping carton.
WARNING
To reduce the risk of re, electric shock, or injury to persons, observe the
following.
Shut off power to the circuit you will be attaching the hood to at the
circuit breaker panel or fuse box.
Determine which venting method to use: roof, wall, or nonvented.
Select a at surface for assembling the range hood.
Place a covering over that surface.
Always have 2 or more persons lift or move the range hood.
Mounting the duct cover bracket
1. Determine and mark the centerline on the wall where the canopy
hood will be installed. Shut off power at the circuit breaker panel or
fuse box.
2. Select a mounting height of no less than 24” (61 cm) above an electric
cooking surface or 27” (68.6 cm cm) above a gas cooking surface.
3. Tape the template in place, aligning the template center line and
bottom with the hood center line and hood bottom line marked on
the wall.
A
B
C
A. Centerline
B. Fastener locations
C. Mounting height reference (hood bottom line)
4. Mark the centers of the fastener locations on the wall by pushing a
pencil point through the template.
IMPORTANT: All screws must be installed into the wood studs or
framing. If there is no wood to screw into, additional wall framing
supports may be required.
5. Remove the template.
6. Drill
3
16 (4.8 mm) pilot holes at all locations where screws are going
to be installed into wood.
7. Install the 2 - 5 x 45 mm mounting screws. Leave a
1
4 (6.4 mm) gap
between the wall and the back of the screw head to slide the range
hood into place.
1
4″ (6.4 mm)
8. Attach the vent cover bracket to the wall ush to the ceiling using 2 -
5 x 45mm screws.
A
B
C
D
A. 8 x 40 mm anchors
B. Centerline on wall
C.Vent cover support bracket
D. 5 x 45 mm screws
Complete preparation
1. Determine and make all necessary cuts in the wall for the vent system.
Install the vent system before installing the hood. See “Venting
Requirements” section.
2. Determine the required height for the home power supply cable and
drill a 1¼” (3.2 cm) hole at this location.
3. Run the home power supply cable according to the National Electrical
Code or CSA Standards and local codes and ordinances. There must
be enough ½” conduit and wires from the fused disconnect (or circuit
breaker) box to make the connection in the hood’s electrical terminal
box.
NOTE
Do not turn on power until the installation is complete.
4. Use caulk to seal all openings
Installation
Installation
English 7
Installation
Install the Range Hood
WARNING
USE TWO OR MORE PEOPLE TO MOVE AND INSTALL THE RANGE
HOOD. FAILURE TO DO SO CAN RESULT IN BACK OR OTHER
INJURY.
1. Mark the lower mounting hole locations with a pencil .
2. Uninstall the hood assembly, and drill
3
16”” (4.8 mm) pilot holes at
the marked locations.
3. Hang the range hood again on 2 the upper mounting screws.
4. Level the range hood and tighten the upper mounting screws.
5. Install 2 - 5 x 45 mm lower mounting screws and tighten. Use the
optional wall anchors if needed.
A
B
C
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
Connect the vent system
1. Install the transition on top of the hood (if removed for shipping) with
2-3.5x9.5 mm sheet metal screws.
A
B
A. Vent transition
B. 3.5 x 9.5 mm screw
For vented installations only
1. Fit the vent system over the exhaust outlet.
2. Measure from the bottom of the air deector to the bottom of the
hood outlet. Cut the ductwork at the measured dimension.
Roof Outlet
Dimension to
measure
Wall
outlet
3. Seal the connection with clamps.
4. Conrm that the back draft dampers work properly
Install the Duct Covers
When using both upper and lower vent covers, push the lower cover
down onto the hood and lift the upper cover to the ceiling, and then install
with two mounting screws.
NOTE
For vented installations, the upper vent cover may be reversed to hide
slots.
A
C
E
C
D
A.. Upper vent cover
B. Lower vent cover
C. 2.9 x 6.5 mm screws
D. Bracket
Installation
8 English
NOTE
To prevent scratches, lay paper or a kitchen towel over the edges of the
lower ue duct to protect the surface.
Complete Installation
For non-vented (recirculating) installations only, install charcoal
lters over metal grease lter. See the “Accessories” section.
Install metal lters. See the “Maintenance” section.
Electrical Connection
WARNING
Electrical shock hazard.
WARNING
Shut off power at the circuit breaker panel or fuse box before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
Electrically ground the blower.
Connect the ground wire to the green and yellow ground wire in the
terminal box. Failure to do so can result in death or electrical shock.
1. Shut off power at the circuit breaker panel or fuse box.
2. Remove the terminal box cover.
3. Remove the knockout in the terminal box cover and install a UL listed
or CSA approved
1
2
” strain relief.
4. Run the home power supply cable through the strain relief, into
the terminal box.
A
B
C
E
D
A. Home power supply cable
B. UL listed wire connectors
C. White wires (N)
D. Black wires (L)
E. Green (or bare) and
yellow-green ground
5. Use UL listed wire connectors and connect the black wires (D)
together.
6. Use UL listed wire connectors and connect the white wires (C)
together.
7. Connect the green (or bare) ground wire from the home power supply
to the yellow-green ground wire (E) in the terminal box using UL listed
wire connectors.
8. Tighten the strain relief screw.
9. Install the terminal box cover.
10. Turn on the power.
To get the most efcient use from your new range hood, read the
“Maintenance” section. Keep your Use, Care, and installation Guide close
to the range hood for easy reference.
Installation
Installation
English 9
Range Hood Use and Care
Description of the Hood
1
2
3
4
5
1. Blower and light controls
2. LED lamps
3. Grease lter handle
4. Grease lters
5. Duct covers
Control
A B C ED
A. Light On/Off
B. Off button
C. Low button
D. Med button
E. High button
Operating the light
The Light On/Off button (A) controls both lights. Press once
for On and again for Off.
Operating the blower
The Blower OFF button (B) turns the blower off.
The Blower Speed buttons (C,D,E) set the desired speed and control the
sound level for quiet operation. The speed can be changed anytime dur-
ing fan operation by pressing the desired blower speed button.
1. To Turn the Blower On, press a Blower Speed button (C,D,E).
2. To Turn the Blower off, press the Blower OFF Button (B).
Maintenance
Cleaning
Do not spray cleaners directly onto the controls while cleaning the Hood.
The hood should be cleaned regularly internally (at least as often as you
clean the grease lters and externally. Clean using a cloth dampened with
neutral liquid detergent. Do not use abrasive products.
DO NOT USE ALCOHOL!
Grease Filter
Traps cooking grease particles. Th grease lter must be cleaned once a
month using a mild detergent, either by hand or in a dishwasher, which
must be set to a low temperature and a short cycle. When washed in a
dishwasher, the grease lter may discolor slightly, but this does not affect
its ltering capacity. To remove the grease lter, pull the spring release
handle.
A
A. Spring release handle
WARNING
Failure to carry out these basic cleaning recommendations for the
hood and failure to clean the grease lter may cause re risks.
Therefore, we strongly recommend you follow these instructions.
Samsung is not responsible for any damage to the motor or for any
re damage linked to inappropriate maintenance or failure to observe
these cleaning and safety recommendations.
Replacing a LED lamp
The LED lights are replaceable by a service technician only. See the
warranty for service contact information.
Range Hood Use and CareRange Hood Use and Care
10 English
Accessories
For non-vented (recirculating) installation only
NOTE
To reduce the risk of re or shock when the hood is used in recirculation
mode, use only the conversion kit models listed below:
Recirculating kit: NK-AF020FNB/AA
Charcoal Filter Replacement kit: NK-AR040FNB/AA
To attach the recirculation kit, follow these steps:
1. Assemble the air deector with the duct cover bracket with 2 -
assembly screws provided with the Recirculation Kit.
A
B
C
D
A. Vent cover bracket
B. 2.9 x 6.5 mm screws
C. Deector
2. Measure from the bottom of the air deector to the bottom of the
hood outlet.
A
B
C
D
X
E
A. Air deector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet
3. Cut the duct to the measured size (X).
4. Remove the air deector.
5. Slide the duct onto the bottom of the air deector.
6. Place the assembled air deector and duct over the exhaust outlet
from the hood.
7. Re-attach the air deector to the duct cover bracket with 2
assembly screws.
8. Seal the connections with vent clamps
Charcoal lter
The charcoal lter is not washable. It should last up to 6 months
with normal use. Replace with Charcoal Filter Replacement Kit.
To replace charcoal lter:
1. Remove the metal grease lter from the range hood.
2. Bend the spring clips away from the metal grease lter.
3. Place the charcoal lter into the top side of metal lter.
4. Insert the metal grease lter back into the range hood.
Range Hood for ADA Compliance
Range Hood Use and Care
Range Hood Use and Care
English 11
Range hoods can be installed to comply with Sections 308 and 309 of
ADA Guidelines, when used with appropriately mounted controls installed
at 15” (38.1 cm) to 40” (101.6 cm) above the oor and control access
does not require reaching over a cooking appliance.
The following range hoods NK30R5000WS, NK36R5000WS,
NK30R5000WG, NK36R5000WG can work in an ADA Compliant
situation when the range hood is wired to operate from a dedicated,
standard electrical wall switch. To facilitate this application, share the
information on the following pages with your electrician when preparing
for the installation.
NOTE
All the models can be controlled by only one remote switch (The switch
activates or deactivates the motor and the light of the hood).
WARNING
All electrical work must be done in accordance with local codes,
ordinances, or the national electrical code as applicable. For safety, this
product must be installed in a grounded switch box. The electrical wiring
installation must be done by a qualied technician.
WARNING
Electrical Shock Hazard
Turn off power at the circuit breaker panel or fuse box before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
(L, ground)
D
E
B
C
F
G
H
E
A
(N, ground)
POWER SUPPLY HOME
G
A. Range Hood Cable
B. UL listed wire connector
C. White wires (N)
D. Black wires (L)
E. Green (or bare) and
yellow-green ground
F. UL listed switch
G. Home power supply cable
H. Deep single gang switch box
Range Hood Use and CareRange Hood Use and Care
WARNING
To avoid re or electrical shock, turn off power at the circuit breaker
panel or fuse box. Conrm that the power is off before wiring.
1. MOUNT THE SWITCH BOX . Install a 3½” deepsingle gang switch
box
2. ATTACH THE POWER CABLE. Clamp wiring to the switch box and
unit using an appropriate clamp. Provide 6” leads inside the box and
fan for easier wiring.
3. CONNECT THE WIRING. General instructions:
Make sure both the switch box and the appliance are properly
grounded.
Make sure the ground wire is securely fastened to the control’s
ground screw. Tighten the ground screw.
Use proper wire nut sizes for the number and size of the wires.
For push-in and screw terminals: Use min. #14 AWG solid copper
wire only.
Tighten the screw terminals.
Make electrical connections following the appropriate diagram.
BLACK
WHITE
APPLIANCE
GRND
120 VAC
LOAD
SINGLE
G ANG
SWITCH
BOX
N
L
4. MOUNT THE CONTROL IN THE SWITCH BOX. Tuck wires into
the switch box and fasten the control to the box using the attached
screws.
5. ATTACH THE SWITCH PLATE. Fasten the switch plate to the control
using the short screws from the parts bag.
Range Hood Use and Care
warranty (USA)
SAMSUNG RANGE HOOD
Limited warranty to original purchaser
This SAMSUNG brand product, as supplied and distributed by
Samsung Electronics America, Inc. (SAMSUNG) and delivered
new, in the original carton to the original consumer purchaser, is
warranted by SAMSUNG against manufacturing defects in mate-
rials and workmanship for a limited warranty period of:
ONE (1) YEAR PARTS AND LABOR
This limited warranty begins on the original date of purchase,
and is valid only on products purchased and used in the United
States. To receive warranty service, the purchaser must contact
SAMSUNG for problem determination and service procedures.
Warranty service can only be performed by a SAMSUNG au-
thorized service center. The original dated bill of sale must be
presented upon request as proof of purchase to SAMSUNG or
SAMSUNG’s authorized service center.
SAMSUNG will repair or replace this product, at our option and
at no charge as stipulated herein, with new or reconditioned
parts or products if found to be defective during the limited
warranty period specied above. All replaced parts and prod-
ucts become the property of SAMSUNG and must be returned
to SAMSUNG. Replacement parts and products assume the
remaining original warranty, or ninety (90) days, whichever is
longer.
In-home service will be provided during the warranty labor
period subject to availability within the contiguous United States.
In-home service is not available in all areas. To receive in-home
service, the product must be unobstructed and accessible to
service personnel. If during in-home service repair can not be
completed, it may be necessary to remove, repair and return the
product.
This limited warranty covers manufacturing defects in materials
and workmanship encountered in normal, noncommercial use of
this product and shall not apply to the following, including, but
not limited to: damage which occurs in shipment; delivery and
installation; applications and uses for which this product was not
intended; altered product or serial numbers; cosmetic damage
or exterior nish; accidents, abuse, neglect, re, water, lightning
or other acts of nature; use of products, equipment, systems,
utilities, services, parts, supplies, accessories, applications,
installations, repairs, external wiring or connectors not supplied
or authorized by SAMSUNG which damage this product or result
in service problems; incorrect electrical line voltage, uctuations
and surges; customer adjustments and failure to follow operating
instructions, cleaning, maintenance and environmental instruc-
tions that are covered and prescribed in the instruction book;
problems caused by pest infestations, and overheating by user.
THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE
LISTED AND DESCRIBED ABOVE, AND NO WARRANTIES
WHETHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT
LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANT-
ABILITY OR FITNESS FOR A PARTICULAR PURPOSE, SHALL
APPLY AFTER THE EXPRESS WARRANTY PERIODS STATED
ABOVE, AND NO OTHER EXPRESS WARRANTY OR GUAR-
ANTY GIVEN BY ANY PERSON, FIRM OR CORPORATION
WITH RESPECT TO THIS PRODUCT SHALL BE BINDING ON
SAMSUNG. SAMSUNG SHALL NOT BE LIABLE FOR LOSS OF
REVENUE OR PROFITS, FAILURE TO REALIZE SAVINGS OR
OTHER BENEFITS, OR ANY OTHER SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES CAUSED BY THE USE, MISUSE
OR INABILITY TO USE THIS PRODUCT, REGARDLESS OF
THE LEGAL THEORY ON WHICH THE CLAIM IS BASED, AND
EVEN IF SAMSUNG HAS BEEN ADVISED OF THE POSSIBILITY
OF SUCH DAMAGES. NOR SHALL RECOVERY OF ANY KIND
AGAINST SAMSUNG BE GREATER IN AMOUNT THAN THE
PURCHASE PRICE OF THE PRODUCT SOLD BY SAMSUNG
AND CAUSING THE ALLEGED DAMAGE. WITHOUT LIMITING
THE FOREGOING, PURCHASER ASSUMES ALL RISK AND
LIABILITY FOR LOSS, DAMAGE OR INJURY TO PURCHASER
AND PURCHASER’S PROPERTY AND TO OTHERS AND THEIR
PROPERTY ARISING OUT OF THE USE, MISUSE OR INABILITY
TO USE THIS PRODUCT SOLD BY SAMSUNG NOT CAUSED
DIRECTLY BY THE NEGLIGENCE OF SAMSUNG. THIS LIMITED
WARRANTY SHALL NOT EXTEND TO ANYONE OTHER THAN
THE ORIGINAL PURCHASER OF THIS PRODUCT IS NON-
TRANSFERABLE AND STATES YOUR EXCLUSIVE REMEDY.
Some provinces or territories may or may not allow limitations on
how long an implied warranty lasts, or the exclusion or limitation
of incidental or consequential damages, so the above limitations
or exclusions may not apply to you. This warranty gives you
specic legal rights, and you may also have other rights which
vary from state to state.
To obtain warranty service, please contact SAMSUNG at:
1-800-SAMSUNG (726-7864) or
www.samsung.com/us/support
warranty (Canada)
SAMSUNG RANGE HOOD
Limited warranty to original purchaser
This SAMSUNG brand product, as supplied and distributed by
Samsung Electronics Canada, Inc. (SAMSUNG) and delivered
new, in the original carton to the original consumer purchaser, is
warranted by SAMSUNG against manufacturing defects in mate-
rials and workmanship for a limited warranty period of:
ONE (1) YEAR PARTS AND LABOR
This limited warranty begins on the original date of purchase,
and is valid only on products purchased and used in Canada. To
receive warranty service, the purchaser must contact SAMSUNG
for problem determination and service procedures. Warranty ser-
vice can only be performed by a SAMSUNG authorized service
center. The original dated bill of sale must be presented upon
request as proof of purchase to SAMSUNG or SAMSUNG’s
authorized service center.
SAMSUNG will repair or replace this product, at our option and
at no charge as stipulated herein, with new or reconditioned
parts or products if found to be defective during the limited
warranty period specied above. All replaced parts and prod-
ucts become the property of SAMSUNG and must be returned
to SAMSUNG. Replacement parts and products assume the
remaining original warranty, or ninety (90) days, whichever is
longer.
In-home service will be provided during the warranty labor
period subject to availability within the contiguous Canada.
In-home service is not available in all areas. To receive in-home
service, the product must be unobstructed and accessible to
service personnel. If during in-home service repair can not be
completed, it may be necessary to remove, repair and return the
product.
This limited warranty covers manufacturing defects in materials
and workmanship encountered in normal, noncommercial use of
this product and shall not apply to the following, including, but
not limited to: damage which occurs in shipment; delivery and
installation; applications and uses for which this product was not
intended; altered product or serial numbers; cosmetic damage
or exterior nish; accidents, abuse, neglect, re, water, lightning
or other acts of nature; use of products, equipment, systems,
utilities, services, parts, supplies, accessories, applications,
installations, repairs, external wiring or connectors not supplied
or authorized by SAMSUNG which damage this product or result
in service problems; incorrect electrical line voltage, uctuations
and surges; customer adjustments and failure to follow operating
instructions, cleaning, maintenance and environmental instruc-
tions that are covered and prescribed in the instruction book;
problems caused by pest infestations, and overheating by user.
SAMSUNG does not warrant uninterrupted or error-free opera-
tion of the product.
THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE
LISTED AND DESCRIBED ABOVE, AND NO WARRANTIES
WHETHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT
LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANT-
ABILITY OR FITNESS FOR A PARTICULAR PURPOSE, SHALL
APPLY AFTER THE EXPRESS WARRANTY PERIODS STATED
ABOVE, AND NO OTHER EXPRESS WARRANTY OR GUAR-
ANTY GIVEN BY ANY PERSON, FIRM OR CORPORATION
WITH RESPECT TO THIS PRODUCT SHALL BE BINDING ON
SAMSUNG. SAMSUNG SHALL NOT BE LIABLE FOR LOSS OF
REVENUE OR PROFITS, FAILURE TO REALIZE SAVINGS OR
OTHER BENEFITS, OR ANY OTHER SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES CAUSED BY THE USE, MISUSE
OR INABILITY TO USE THIS PRODUCT, REGARDLESS OF
THE LEGAL THEORY ON WHICH THE CLAIM IS BASED, AND
EVEN IF SAMSUNG HAS BEEN ADVISED OF THE POSSIBILITY
OF SUCH DAMAGES. NOR SHALL RECOVERY OF ANY KIND
AGAINST SAMSUNG BE GREATER IN AMOUNT THAN THE
PURCHASE PRICE OF THE PRODUCT SOLD BY SAMSUNG
AND CAUSING THE ALLEGED DAMAGE. WITHOUT LIMITING
THE FOREGOING, PURCHASER ASSUMES ALL RISK AND
LIABILITY FOR LOSS, DAMAGE OR INJURY TO PURCHASER
AND PURCHASER’S PROPERTY AND TO OTHERS AND THEIR
PROPERTY ARISING OUT OF THE USE, MISUSE OR INABILITY
TO USE THIS PRODUCT SOLD BY SAMSUNG NOT CAUSED
DIRECTLY BY THE NEGLIGENCE OF SAMSUNG. THIS LIMITED
WARRANTY SHALL NOT EXTEND TO ANYONE OTHER THAN
THE ORIGINAL PURCHASER OF THIS PRODUCT IS NON-
TRANSFERABLE AND STATES YOUR EXCLUSIVE REMEDY.
Some provinces or territories may or may not allow limitations on
how long an implied warranty lasts, or the exclusion or limitation
of incidental or consequential damages, so the above limitations
or exclusions may not apply to you. This warranty gives you
specic legal rights, and you may also have other rights which
vary from state to state.
To obtain warranty service, please contact SAMSUNG at:
1-800-SAMSUNG (726-7864) or
www.samsung.com/ca/support (English),
www.samsung.com/ca_fr/support (French)
14 Français
Sommaire
Sommaire
Importantes Consignes de Sécurité 15
Exigences d’Installation 17
Spécications Électriques 17
Exigences Concernant l’évacuation 17
Méthodes d’évacuation 17
Outils et Pièces 18
Dimensions et Espaces 18
Installation de la Hotte 19
Instructions d´installation 19
Montage du support de couvercle de conduit 19
Installation sur le mur 20
Installer les Couvre-conduits 20
Connexion Électrique 21
Utilisation de la hotte 22
Description de la hotte 22
Commandes de la hotte 22
Entretien 22
Accessoires 23
Hotte de cuisinière pour conformité ADA 24
Garantie (USA) 25
Garantie (Canada) 26
Français 15
APPROUVÉ POUR LES APPAREILS DE TYPE RÉSIDENTIEL POUR
UNE UTILISATION RÉSIDENTIELLE SEULEMENT LISEZ CES
INSTRUCTIONS ET CONSERVEZ-LES
VEUILLEZ LIRE CES INSTRUCTIONS AU COMPLET AVANT DE
COMMENCER.
L’INSTALLATION DE L’APPAREIL DOIT RESPECTER TOUS LES
CODES EN VIGUEUR.
IMPORTANT:
INSTALLATEUR:
PROPRIÉTAIRE:
Conservez ces instructions an de pouvoir les
remettre à l’inspecteur-électricien de votre
région.
Veuillez laisser ces instructions avec l’appareil
pour le propriétaire.
Veuillez conserver ces instructions pour pouvoir
vous y référer plus tard.
Symboles utilisés dans ce manuel
AVERTISSEMENT
Dangers ou pratiques dangereuses qui peuvent entraîner des blessures
personnelles graves ou la mort.
ATTENTION
Dangers ou practiques dangereuses qui peuvent entraîner un choc
électrique, des blessures personnelles ou des dommages matériels.
REMARQUE
Des conseils et des instructions utiles
Ces icônes et ces symboles d’avertissement sont là pour prévenir des
blessures qui peuvent vous arriver aussi bien à vous qu’aux autres.
S’il vous plaît suivez-les de manière explicite. Après avoir lu cette section,
le conserver dans un endroit sure pour des références futures.
AVERTISSEMENT
Coupez l’alimentation du circuit dans le panneau électrique et verrouillez
le panneau avant de raccorder les ls de cet appareil.
Exigence 120 V c.a., 60 Hz circuit de dérivation de 15 V c.a., 20 Hz, de
15 ou 20 A.
Etat de Californie Proposition 65 avertissement (Etats-Unis
seulement)
AVERTISSEMENT
Ce produit contient des produits chimiques reconnus par l’Etat de
Californie comme pouvant provoquer des cancers et des malformations
congénitales ou autres problèmes de reproduction.
AVERTISSEMENT
POUR RÉDUIRE LE RISQUE D’INCENDIE, CHOC ÉLECTRIQUE
OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS
SUIVANTES:
Utiliser cet appareil uniquement dans les applications envisagées par
le fabricant. Pour toute question, contacter le fabricant.
Avant d’entreprendre un travail d’entretien ou de nettoyage,
interrompre l’alimentation de la hotte au niveau du tableau de
disjoncteurs, et verrouiller le tableau de disjoncteurs pour empêcher
tout rétablissement accidentel de l’alimentation du circuit. Lorsqu’il
n’est pas possible de verrouiller le tableau de disjoncteurs, placer
sur le tableau de disjoncteurs une étiquette d’avertissement
proéminente interdisant le rétablissement de l’alimentation.
Tout travail d’installation ou câblage électrique doit être réalisé par
une personne qualiée, dans le respect des prescriptions de tous
les codes et normes applicables, y compris les codes du bâtiment et
de protection contre les incendies.
Importantes Consignes de Sécurité
Importantes Consignes de Sécurité
Une source d’air de débit sufsant est nécessaire pour le
fonctionnement correct de tout appareil à gaz (combustion et
évacuation des gaz à combustion par la cheminée), pour qu’il
n’y ait pas de reux des gaz de combustion. Respecter les
directives du fabricant de l’équipement de chauffage et les
prescriptions des normes de sécurité - comme celles publiées par
la National Fire Protection Association (NFPA) et l’American Society
for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE),
et les prescriptions des autorités réglementaires locales.
Lors d’opérations de découpage et de perçage dans un mur ou un
plafond, veiller à ne pas endommager les câblages électriques ou
canalisations qui peuvent s’y trouver.
Les ventilateurs d’évacuation doivent toujours décharger l’air à
l’extérieur.
ATTENTION
Cet appareil est conçu uniquement pour la ventilation générale. Ne pas
l’utiliser pour l’extraction de matières ou vapeurs dangereuses ou explo-
sives.
ATTENTION
Pour minimiser le risque d’incendie et évacuer adéquatement les gaz,
veiller à acheminer l’air aspiré par un conduit jusqu’à l’extérieur - ne
pas décharger l’air aspiré dans un espace vide du bâtiment comme une
cavité murale, un plafond, un grenier, un vide sanitaire ou un garage.
AVERTISSEMENT
POUR RÉDUIRE LE RISQUE D’INCENDIE, UTILISER UNIQUEMENT
DES CONDUITS MÉTALLIQUES.
AVERTISSEMENT
POUR MINIMISER LE RISQUE D’UN FEU DE GRAISSE SUR LA CUI-
SINIÈRE:
Ne jamais laisser un élément de surface fonctionner à puissance de
chauffage maximale sans surveillance. Un renversement/
débordement de matière graisseuse pourrait provoquer une
inammation et la génération de fumée. Utiliser une puissance de
chauffage moyenne ou basse pour le chauffage d’huile.
Veiller à toujours faire fonctionner le ventilateur de la hotte lors de la
cuisson avec une puissance de chauffage élevée ou lors de la
cuisson d’un mets à amber (à savoir crêpes Suzette, cerise jubilée,
steak au poivre ambé).
Nettoyer fréquemment les ventilateurs d’extraction. Veiller à ne pas
laisser la graisse s’accumuler sur les surfaces du ventilateur ou des
ltres.
Utiliser toujours un ustensile de taille appropriée. Utiliser toujours un
ustensile adapté à la taille de l’élément chauffant.
16 Français
Importantes Consignes de Sécurité
AVERTISSEMENT
POUR RÉDUIRE LE RISQUE DE DOMMAGES CORPORELS APRÈS
LE DÉCLENCHEMENT D’UN FEU DE GRAISSE SUR LA CUISINIÈRE,
APPLIQUER LES RECOMMANDATIONS SUIVANTES:
a
Placer sur le récipient un couvercle bien ajusté, une tôle à biscuits ou
un plateau métallique POUR ÉTOUFFER LES FLAMMES, puis
éteindre le brûleur. VEILLER À ÉVITER LES BRÛLURES. Si les
ammes ne s’éteignent pas immédiatement, ÉVACUER LA PIÈCE
ET APPELER LES POMPIERS.
NE JAMAIS PRENDRE EN MAIN UN RÉCIPIENT ENFLAMMÉ -
vous risquez de vous brûler.
NE PAS UTILISER D’EAU, ni un torchon humide - ceci pourrait
provoquer une explosion de vapeur brûlante.
Utiliser un extincteur SEULEMENT si:
Il s’agit d’un extincteur de classe ABC, dont on connaît
le fonctionnement.
Il s’agit d’un petit feu encore limité à l’endroit où il s’est déclaré.
Les pompiers ont été contactés.
Il est possible de garder le dos orienté vers une sortie pendant
l’opération de lutte contre le feu.
a
Recommandations tirées des conseils de sécurité en cas d’incendie de
cuisine publiés par la NFPA.
AVERTISSEMENT
Pour réduire le risque d’incendie ou de choc électrique, ne pas utiliser
ce ventilateur avec un quelconque dispositif de réglage de la vitesse à
semiconducteurs.
AVERTISSEMENT
Ne pas laisser les enfants à proximité de cet appareil. Ne laissez pas
les enfants jouer avec cet appareil. Conservez tous les matériaux
d’emballage hors de la portée des enfants.
Jetez les matériaux d’emballage après que cet appareil ait été déballé.
Importantes Consignes de Sécurité
Lire et conserver ces Instructions
Français 17
Spécications Électriques
IMPORTANT
Observer les dispositions de tous les codes et règlements en vigueur.
Le client a la responsabilité de:
Contacter un électricien-installateur.
Vérier que l’installation électrique est adéquate et conforme avec le
Code national de l’électricité, ANSI/NFPA 70 (la plus récente édition*), ou
les normes C22.1-94, Code canadien de l’électricité, Partie 1 et C22.2
No.0-M91(La plus récente édition**) de la CSA, ainsi que tous les codes
et les ordonnances de votre région.
Si le code le permet et que vous utilisez un l de mise à la terre distinct, il
est recommandé de faire vérier le chemin du l par un électricien.
Pour obtenir un exemplaire des normes des codes ci-dessus, contacter:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
L’appareil doit être alimenté par un circuit de 120 V CA seulement,
60 Hz, 15 ampères, protégé par fusible.
Si le domicile est équipé d’un câblage en aluminium, suivre les
instructions suivantes:
1. Raccorder une section de câble en cuivre massif aux conducteurs en
queue de cochon.
2. Connecter le câblage en aluminium à la section ajoutée de câblage
en cuivre en utilisant des connecteurs et/ou des outils spécialement
conçus et homologués UL pour xer le cuivre à l’aluminium.
Suivre la procédure recommandée par le fabricant de connecteurs
électriques. Les raccordements aluminium/ cuivre doivent
satisfaire aux prescriptions des codes locaux et de l’industrie, et être
conformes aux pratiques de câblage reconnues.
Le calibre des conducteurs et les connexions doivent être compatibles
avec les caractéristiques électriques de l’appareil spéciées sur la
plaque signalétique. La plaque signalétique de l’appareil est située
derrière le ltre, sur la paroi arrière de la hotte.
Le calibre des conducteurs doit être conforme aux exigences du
National Electrical Code, de la plus récente édition de la norme ANSI/
NFPA 70 ou des normes CSA C22. 1-94, Code canadien de
l’électricité, partie 1 et C22.2 n° 0-M91 (édition la plus récente) et de
tous les codes et règlements en vigueur.
Exigences Concernant l’évacuation
Le système de ventilation doit se terminer à l’extérieur.
Pour une évacuation d’air optimale, utilisez une ligne droite ou
le moins de coudes possible. MISE EN GARDE: Ventilez l’appareil
uniquement à l’extérieur du bâtiment.
Au moins deux personnes sont nécessaires pour l’installation.
Le matériel de xation est fourni pour xer la hotte à la plupart
des types de murs et de plafonds. Consultez un installateur qualié.
Conrmez que les raccords s’adaptent parfaitement à votre armoire /
mur.
Ne pas utiliser de conduits exibles.
Les installations PAR TEMPS FROID devraient avoir un registre
anti-retour supplémentaire installé an de minimiser le ux d’air froid
vers l’arrière et une coupure thermique non métallique pour minimiser
la conduction des températures extérieures dans les conduits. Le
registre doit être du côté de l’air froid de la coupure thermique.
La pause doit être aussi proche que possible de l’endroit où les
conduits entrent dans la partie chauffée de la maison.
Méthodes d’évacuation
Suivez attentivement les instructions données dans ce manuel. Samsung
ne peut être tenu responsable des éventuels désagréments, dommages ou
incendies résultant du non-respect des instructions de ce manuel.
Version canalisation
La hotte est équipée d’une transition rond de 6 ”(15.2 cm) pour l’évacuation
des fumées vers l’extérieur.
Décharge horizontale Décharge verticale Version sans conduit
(Recyclage)
A
B
A
B
A
B
A. Bouche de décharge sur le mur
B. Conduit rond de 6” (15,2
cm)
A. Bouche de décharge sur toit
B. Conduit rond de 6” (15,2 cm)
A. Deecteur
B. Conduit rond de 6” (15,2 cm)
Préparation
Ne coupez pas une solive ou un poteau, sauf en cas de nécessité absolue.
Si une solive ou un poteau doit être coupé, un cadre porteur doit être
construit. Le matériel de xation est fourni pour xer la hotte à la plupart
des types de murs / plafonds. Cependant, un technicien qualié doit vérier
l’adéquation des matériaux en fonction du type de mur / plafond. Avant de
faire des découpes, assurez-vous qu’il y a un dégagement sufsant dans le
plafond ou le mur pour le conduit d’évacuation.
Version sans conduit (recirculation)
Dans les cas où il n’est pas possible d’évacuer les vapeurs et les vapeurs
de cuisson à l’extérieur, xez un ltre à charbon et le déecteur sur le sup-
port de cache-conduit. Les fumées et les vapeurs sont recyclées à travers
la grille supérieure au moyen d’un conduit relié à la transition et à la transi-
tion montée sur le déecteur.
REMARQUE
Pour une décharge horizontale uniquement: achetez le kit de recirculation sans
conduit. Taille minimale du conduit: tuyau rond de 6 “.
ATTENTION
Pour les tables de cuisson et les cuisinières électriques / à induction:
Montez la hotte de sorte que le fond se trouve à au moins 24” (61cm)
de la surface de cuisson.
Pour les tables de cuisson au gaz et les cuisinières: Montez la hotte
de sorte que le fond se trouve à au moins 27” (68.6 cm) au-dessus de
la surface de cuisson.
Dans les deux cas, ne montez pas à plus de 36” (91.4 cm) au-dessus
de la surface de cuisson.
Mesurez la hauteur de montage de la surface de la cuisinière au bas
de la hotte.
AVERTISSEMENT
Cette hotte est destinée à un usage domestique.
VEUILLEZ LIRE LE MANUEL D’INSTALLATION POUR L’APPLICATION
SPÉCIFIQUE DE LA HOTTE. Vériez la hauteur de votre plafond et celle
de la hotte avant de choisir votre hotte.
Exigences d’Installation
Exigences d’Installation
18 Français
Outils et Pièces
Enlever l’emballage
ATTENTION
Enlever délicatement le carton. Porter des gants pour se protéger
des bords coupants.
AVERTISSEMENT
Enlever le lm de protection recouvrant le produit avant de
commencer l’opération.
Outils et pièces
Hotte avec ventilateur et lampes DEL
Kit quincaillerie comprenant:
Pièce Qty Pièce Qty
5x45 mm
6
8x40 mm
2
5.4x75 mm
4
10x60 mm
4
3.5x9.5 mm
2
Support de couverture
de conduit
1
2.9x6.5 mm
2
Gabarit de montage
1
Couvertures De
Conduits
2
6” transition ronde
1
Outils nécessaires
Niveau
Perceuse avec forets de 1¼” (3.2 cm),1⁄8” (3.2 mm), y 1⁄16” (4,8 mm)
Crayon
Pince à dénuder ou couteau utilitaire
Mètre-ruban ou règle
Pince
Pistolet à calfeutrage et composé de calfeutrage résistant aux
intempéries
Brides de conduit
Scie sauteuse ou scie à guichet
Tournevis à lame plate
Cisaille de ferblantier
Tournevis Phillips (Pozidrive) et tournevis Torx 20
Pièces nécessaires
Câble d’alimentation électrique du domicile
Serre-câble de
1
2” (12,7 mm) (homologation UL ou CSA)
3 connecteurs de ls homologués UL
1 bouche de décharge (décharge à travers le mur ou à travers le toit)
Circuit d’évacuation métallique
Exigences d’Installation
Exigences d’Installation
Accessoires optionnel
MODÉLE
NK30R5000WS
NK36R5000WS
NK30R5000WG
NK36R5000WG
Kit d’extension
NK-AE505PWS/AA NK-AE505PWG/AA
Kit de recirculation NK-AF020FNB/AA
Filtre à charbon NK-AR040FNB/AA
* Commandez le kit nécessaire en spéciant le modèle de votre hotte.
Dimensions et Espaces
A
B
D
C
G
F
E
NK30R5000WS
NK36R5000WS
NK30R5000WG
NK36R5000WG
A 30” (76.2 cm) 36″ (91.2 cm)
B 19
11
16″ (50 cm)
C*
Max: 42
1
8″ (107 cm)
Min: 28
6
16″ (72 cm)
D**
Max: 38
3
16″ (97 cm)
Min: 28
6
16″ (72 cm)
E 6” (15.24 cm)
F 7
3
16″ (18.3 cm)
G 8
3
16″ (20.8 cm)
* Seulement avec la version sans conduit (à recyclage)
** Seulement avec la version version à conduit
Français 19
Instructions d’installation
Nous recommandons qu’un technicien qualié installe la hotte. Il est de
la responsabilité de l’installateur de s’assurer que la hotte de cuisine est
conforme aux tolérances d’installation spéciées pour le produit.
Il est recommandé d’installer le système d’évacuation avant de
procéder à l’installation de la hotte.
Si l’on installe un dosseret avec des tablettes pour les lampes à rayons
infrarouges, suivre les instructions fournies avec ce produit-là.
Avant d’exécuter les découpages, vérier la disponibilité d’un
dégagement sufsant dans le plafond ou le mur pour le conduit
d’évacuation.
Vérier que les pièces d’installation ont été retirées du carton
d’expédition.
AVERTISSEMENT
Pour réduire les risques d’incendie, de choc électrique ou de blessure,
observez les points suivants.
1. Déconnecter la source de courant électrique
2. Déterminer la méthode d’évacuation à utiliser: par le toit ou le mur.
REMARQUE: Cette hotte est congurée pour expulser l’air par
la sortie supérieure.
3. Sélectionner une surface plane pour l’assemblage de la hotte. Placer
le matériau de protection sur cette surface.
Montage du support de couvercle de conduit
1. Déterminez et marquez l’axe central sur le mur où la hotte sera
installée. Débranchez le courant.
2. Sélectionnez une hauteur de montage d’au moins 24” (61 cm)
pour une surface de cuisson électrique ou de 27” (68,6 cm) pour
une surface de cuisson à gaz.
3. Collez le gabarit en place en alignant la ligne médiane et la partie
inférieure du gabarit sur la ligne inférieure de la hotte et sur la ligne
médiane marquée au mur.
A
B
C
A. Ligne centrale
B. Emplacement des xations
C. Référence de hauteur de montage (ligne inférieure de la hotte)
4. Marquez les centres des emplacements des xations sur le mur en
poussant un crayon à travers le gabarit.
IMPORTANT: Toutes les vis doivent être installées dans les poteaux
en bois ou la charpente. S’il n’y a pas de bois dans lequel visser, des
supports de charpente supplémentaires peuvent être nécessaires.
5. Retirez le modèle.
6. Percez des avant-trous de
3
16 (4.8 mm) à tous les emplacements
où les vis vont être installées dans le bois.
7. Installez les vis de montage 2 - 5 x 45 mm. Laissez un espace de
1
4
(6.4 mm ) entre le mur et l’arrière de la tête de la vis pour faire glisser
la hotte en place.
1
4″ (6.4 mm)
8. Fixez le support du capot de ventilation au mur au ras du plafond à
l’aide de 2 - 5 x 45 mm vis.
A
B
C
D
A. Ancres de 8 x 40 mm
B. Ligne centrale sur le mur
C. Support de couverture C.Vent
D. Vis de 5 x 45 mm
Achever l’ínstallation
1. Déterminez et faites toutes les coupes nécessaires dans le mur pour
le système de ventilation. Installez le système de ventilation avant
d’installer la hotte. Voir la section «Conditions d’évacuation».
2. Déterminez la hauteur requise pour le câble d’alimentation secteur et
percez un trou de 1¼ ”(3.2 cm) à cet endroit.
3. Branchez le câble d’alimentation secteur conformément au code
national de l’électricité ou aux normes CSA ainsi qu’aux codes et
aux ordonnances locales. Il doit y avoir sufsamment de conduit et
de ls de ½ ”provenant du boîtier de déconnexion à fusible (ou du
disjoncteur) pour effectuer le raccordement dans le boîtier de
raccordement électrique de la hotte.
4. Utilisez du mastic pour sceller toutes les ouvertures
REMARQUE
Ne rebranchez pas l’alimentation avant la n de l’installation.
Installation
Installation
20 Français
Installation sur le mur
AVERTISSEMENT
UTILISER DEUX OU PLUS DE PERSONNES POUR DÉPLACER
ET INSTALLER LA HOTTE DE LA CUISINIÈRE.
LE NON-RESPECT DE CETTE INSTRUCTION PEUT CAUSER
UNE BLESSURE AU DOS OU D’AUTRE BLESSURE.
1. Marquez les emplacements des trous de montage inférieurs avec un
crayon.
2. Désinstallez la hotte et percez des avant-trous de
3
16” (4.8 mm)
aux emplacements marqués.
3. Suspendre à nouveau la hotte sur les 2 vis de xation supérieures.
4. Mettez la hotte à niveau et serrez les vis de xation supérieures.
5. Installez 2 - 5 vis de montage inférieures de 5 x 45 mm et serrez.
Utilisez les ancrages muraux optionnels si nécessaire.
A
B
C
A. Vis de montage
B. Fentes de montage
C. Vis de xation inférieures
Connecter le système de ventilation
1. Installez la transition sur le dessus de la hotte (si elle est retirée pour
l’expédition) à l’aide de vis à tôle 2 - 3.5 x 9.5 mm.
A
B
A. Transition de ventilation
B. Vis 3.5 x 9.5 mm
Pour les installations ventilées seulement
1. Placez le système de ventilation sur la sortie d’échappement.
2. Mesurez depuis le bas du déecteur d’air jusqu’au bas de la
sortie de la hotte. Couper les conduits à la dimension mesurée.
Sortie de toit
Dimension a
mesurer
sortie
du mur
3. Sceller la connexion avec des pinces.
4. Vériez que les amortisseurs de tirage arrière fonctionnent
correctement.
Installer les Couvre-conduits
Lorsque vous utilisez les capots de ventilation supérieur et inférieur,
poussez le capot inférieur sur la hotte et soulevez le capot supérieur
jusqu’au plafond, puis installez-le à l’aide de deux vis de montage.
REMARQUE
Pour les installations ventilées, le capot supérieur de ventilation peut être
inversé pour masquer les fentes.
A
C
E
C
D
A .Couvercle d’évent supérieur
B. Couvercle d’évent inférieur
C. Vis de 2.9 x 6.5 mm
D. Support
Installation
Installation
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Samsung NK36R5000WG/AA Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur