1
Line (Black)
Neutral (White)
DIM+ (Purple)
0-10V
Dimming
Wiring Diagram 2700K
3000K
3500K
4000K
5000K
DIM– (Pink)
Wiring Diagram
Line (Black)
Neutral (White)
DIM+ (Purple)
0-10V
Dimming
DIM– (Pink)
2700K
3000K
3500K
4000K
5000K
COMMERCIAL LED
DOWNLIGHT RETROFITS
Models: S11850, S11851, S11852, S11853
Satco Products, Inc.
Brentwood, NY 11717
RETROFIT INSTALLATION
STEP 1: TURN OFF the electrical power at fuse or circuit breaker
box before wiring xture to power supply. (Figure A)
STEP 2: Locate a suitable position to install the xture and create
a hole in accordance to the dimensions. (Figure B)
NOTE: For NEW CONSTRUCTION see reverse for
installation instructions.
STEP 3: Verify that supply voltage is correct by comparing it with
the downlight specication. Open the connection box cover and
remove the appropriate knockout(s). Make wiring connections as
per wiring diagram. (Figure C) Connect the hot power line (L) wire
into the wire lead from the Whip, connect the neutral (N) wire lead
to the neutral wire lead from the Whip. If using 0-10V dimming;
connect the purple (+) wire lead from the Whip to the dimming
control lead, connect the pink (–) wire lead from the Whip to the
dimming control grey wire lead. (Figure C)
NOTE: The circuit is intended for connection to an
external Class 2 supply.
STEP 4: Important! The color temperature must be set on the
xture before installation into the ceiling. (Figure D)
STEP 5: Connect the xture lead wire from the LED Junction
Box securely to the xture wire lead. (Figure E)
STEP 6: The xture can now be inserted into the ceiling by
compressing the two spring clips to an upright position and
carefully slide the xture into the ceiling hole until the xture trim
ushes up against the ceiling surface. (Figure F)
STEP 7: Once assembly is complete, turn power ON to conrm
xture is working properly.
INSTALLATION AND SAFETY INSTRUCTIONS
IMPORTANT: Read before installing xture. Retain for future reference.
Specications
Operating Temperature = –20°C to +40°C (–4°F to +104°F)
© Copyright 2022 Satco Products, Inc. 8/22 v1.3
Model # Watts Ceiling Aperture
(Hole cut size) Lumens Adjustable
Color Temp. Volts
S11850 12 4.17" (106mm) 1200 2700K
3000K
3500K
4000K
5000K
120–
277V
S11851 16 6.02" (153mm) 1600
S11852 22 7.99" (203mm) 2200
S11853 32 9.45" (240mm) 3200
A B
C D
E F
Line (Black)
Neutral (White)
Ground (Copper)
DIM+ (Purple)
DIM– (Pink)
0-10V
Dimming
Wiring Diagram
2700K
3000K
3500K
4000K
5000K
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
Line (Black)
Neutral (White)
DIM+ (Purple)
0-10V
Dimming
Wiring Diagram 2700K
3000K
3500K
4000K
5000K
DIM– (Pink)
Wiring Diagram
Line (Black)
Neutral (White)
DIM+ (Purple)
0-10V
Dimming
DIM– (Pink)
2700K
3000K
3500K
4000K
5000K
Line (Black)
Neutral (White)
DIM+ (Purple)
0-10V
Dimming
Wiring Diagram 2700K
3000K
3500K
4000K
5000K
DIM– (Pink)
Wiring Diagram
Line (Black)
Neutral (White)
DIM+ (Purple)
0-10V
Dimming
DIM– (Pink)
2700K
3000K
3500K
4000K
5000K
WARNING: Risk of Fire or Electric Shock
• This product must be installed in accordance with the applicable
installation code by a person familiar with the construction and
operation of the product and the hazards involved.
• TURN OFF the electrical power before proceeding.
• To reduce the risk of re and over-heating, secure all connections
are tight.
• To reduce the risk of death, personal injury or property damage
from re, electric shock, falling parts, cuts/abrasions, and other
hazards read all warnings and instructions included with and on
the xture box and all xture labels.
• Installation, service and maintenance of luminaries should be
performed by a qualied licensed electrician.
• This recessed downlight is intended to be connected to a properly
installed and grounded UL listed junction box.
• Do not install if product is damaged.
• Always wear gloves and safety glasses when removing downlight
from carton, installing, servicing or performing maintenance.
• Avoid direct eye exposure to the light source while it is on.
• Wet location rated.
Any changes or modications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority
to operate the equipment.
NOTE: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection