Lincoln Electric Eagle 10,000 Mode d'emploi

Catégorie
Système de soudage
Taper
Mode d'emploi
EAGLE
10,000
OPERATOR’S MANUAL
For Machines with Code Number: 11397
IM926
June, 2009
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thought-
ful operation on your part. DO
NOT INSTALL, OPERATE OR
REPAIR THIS EQUIPMENT
WITHOUT READING THIS
MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED
THROUGHOUT. And, most
importantly, think before you act
and be careful.
R
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
• World's Leader in Welding and Cutting Products •
Copyright © Lincoln Global Inc.
C US
This manual covers equipment which is no
longer in production by The Lincoln Electric Co.
Specications and availability of optional
features may have changed.
FOR ENGINE
powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance
work unless the maintenance work requires it to be running.
____________________________________________________
1.b.Operate engines in open, well-ventilated
areas or vent the engine exhaust fumes
outdoors.
____________________________________________________
1.c. Do not add the fuel near an open flame
welding arc or when the engine is running.
Stop the engine and allow it to cool before
refueling to prevent spilled fuel from vaporiz-
ing on contact with hot engine parts and
igniting. Do not spill fuel when filling tank. If
fuel is spilled, wipe it up and do not start
engine until fumes have been eliminated.
____________________________________________________
1.d. Keep all equipment safety guards, covers and devices in
position and in good repair.Keep hands, hair, clothing and
tools away from V-belts, gears, fans and all other moving
parts when starting, operating or repairing equipment.
____________________________________________________
1.e. In some cases it may be necessary to remove safety
guards to perform required maintenance. Remove
guards only when necessary and replace them when the
maintenance requiring their removal is complete.
Always use the greatest care when working near moving
parts.
___________________________________________________
1.f. Do not put your hands near the engine fan.
Do not attempt to override the governor or
idler by pushing on the throttle control rods
while the engine is running.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while
turning the engine or welding generator during maintenance
work, disconnect the spark plug wires, distributor cap or
magneto wire as appropriate.
i
SAFETY
i
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.
KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you
purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1 from the American Welding Society, P.O. Box
351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available
from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
WARNING
Mar ‘95
ELECTRIC AND
MAGNETIC FIELDS
may be dangerous
2.a. Electric current flowing through any conductor causes
localized Electric and Magnetic Fields (EMF). Welding
current creates EMF fields around welding cables and
welding machines
2.b. EMF fields may interfere with some pacemakers, and
welders having a pacemaker should consult their physician
before welding.
2.c. Exposure to EMF fields in welding may have other health
effects which are now not known.
2.d. All welders should use the following procedures in order to
minimize exposure to EMF fields from the welding circuit:
2.d.1.
Route the electrode and work cables together - Secure
them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and
work cables. If the electrode cable is on your right
side, the work cable should also be on your right side.
2.d.4. Connect the work cable to the workpiece as close as
possible to the area being welded.
2.d.5. Do not work next to welding power source.
1.h. To avoid scalding, do not remove the
radiator pressure cap when the engine is
hot.
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents
are known to the State of California to cause can-
cer, birth defects, and other reproductive harm.
The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
The Above For Diesel Engines
The Above For Gasoline Engines
ii
SAFETY
ii
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover
plates to protect your eyes from sparks and
the rays of the arc when welding or observing
open arc welding. Headshield and filter lens
should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant
material to protect your skin and that of your helpers from
the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable
screening and/or warn them not to watch the arc nor expose
themselves to the arc rays or to hot spatter or metal.
ELECTRIC SHOCK can
kill.
3.a. The electrode and work (or ground) circuits
are electrically “hot” when the welder is on.
Do not touch these “hot” parts with your bare
skin or wet clothing. Wear dry, hole-free
gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation.
Make certain the insulation is large enough to cover your full
area of physical contact with work and ground.
In addition to the normal safety precautions, if welding
must be performed under electrically hazardous
conditions (in damp locations or while wearing wet
clothing; on metal structures such as floors, gratings or
scaffolds; when in cramped positions such as sitting,
kneeling or lying, if there is a high risk of unavoidable or
accidental contact with the workpiece or ground) use
the following equipment:
Semiautomatic DC Constant Voltage (Wire) Welder.
DC Manual (Stick) Welder.
AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode,
electrode reel, welding head, nozzle or semiautomatic
welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical
connection with the metal being welded. The connection
should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical
(earth) ground.
3.f.
Maintain the electrode holder, work clamp, welding cable and
welding machine in good, safe operating condition. Replace
damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically hot parts of
electrode holders connected to two welders because voltage
between the two can be the total of the open circuit voltage
of both welders.
3.i. When working above floor level, use a safety belt to protect
yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
FUMES AND GASES
can be dangerous.
5.a. Welding may produce fumes and gases
hazardous to health. Avoid breathing these
fumes and gases. When welding, keep
your head out of the fume. Use enough
ventilation and/or exhaust at the arc to keep
fumes and gases away from the breathing zone. When
welding with electrodes which require special
ventilation such as stainless or hard facing (see
instructions on container or MSDS) or on lead or
cadmium plated steel and other metals or coatings
which produce highly toxic fumes, keep exposure as
low as possible and within applicable OSHA PEL and
ACGIH TLV limits using local exhaust or mechanical
ventilation. In confined spaces or in some circum-
stances, outdoors, a respirator may be required.
Additional precautions are also required when welding
on galvanized steel.
5. b. The operation of welding fume control equipment is affected
by various factors including proper use and positioning of
the equipment, maintenance of the equipment and the spe-
cific welding procedure and application involved. Worker
exposure level should be checked upon installation and
periodically thereafter to be certain it is within applicable
OSHA PEL and ACGIH TLV limits.
5.c.
Do not weld in locations near chlorinated hydrocarbon
vapors
coming from degreasing, cleaning or spraying operations.
The heat and rays of the arc can react with solvent vapors
to
form phosgene, a highly toxic gas, and other irritating prod-
ucts.
5.d. Shielding gases used for arc welding can displace air and
cause injury or death. Always use enough ventilation,
especially in confined areas, to insure breathing air is safe.
5.e. Read and understand the manufacturer’s instructions for this
equipment and the consumables to be used, including the
material safety data sheet (MSDS) and follow your
employer’s safety practices. MSDS forms are available from
your welding distributor or from the manufacturer.
5.f. Also see item 1.b.
Jan ‘09
iii
SAFETY
iii
FOR ELECTRICALLY
powered equipment.
8.a. Turn off input power using the disconnect
switch at the fuse box before working on
the equipment.
8.b. Install equipment in accordance with the U.S. National
Electrical Code, all local codes and the manufacturers
recommendations.
8.c. Ground the equipment in accordance with the U.S. National
Electrical Code and the manufacturer’s recommendations.
CYLINDER may explode
if damaged.
7.a. Use only compressed gas cylinders
containing the correct shielding gas for the
process used and properly operating
regulators designed for the gas and
pressure used. All hoses, fittings, etc. should be suitable for
the application and maintained in good condition.
7.b. Always keep cylinders in an upright position securely
chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
Away from areas where they may be struck or subjected to
physical damage.
A safe distance from arc welding or cutting operations and
any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other
electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet
when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand
tight except when the cylinder is in use or connected for
use.
7.g. Read and follow the instructions on compressed gas
cylinders, associated equipment, and CGA publication P-l,
“Precautions for Safe Handling of Compressed Gases in
Cylinders,” available from the Compressed Gas Association
1235 Jefferson Davis Highway, Arlington, VA 22202.
WELDING and CUTTING
SPARKS can
cause fire or explosion.
6.a.
Remove fire hazards from the welding area.
If this is not possible, cover them to prevent
the welding sparks from starting a fire.
Remember that welding sparks and hot
materials from welding can easily go through small cracks
and openings to adjacent areas. Avoid welding near
hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site,
special precautions should be used to prevent hazardous
situations. Refer to “Safety in Welding and Cutting” (ANSI
Standard Z49.1) and the operating information for the
equipment being used.
6.c. When not welding, make certain no part of the electrode
circuit is touching the work or ground. Accidental contact
can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the
proper steps have been taken to insure that such procedures
will not cause flammable or toxic vapors from substances
inside. They can cause an explosion even
though
they have
been “cleaned”. For information, purchase “Recommended
Safe Practices for the
Preparation
for Welding and Cutting of
Containers and Piping That Have Held Hazardous
Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or
welding. They may explode.
6.f.
Sparks and spatter are thrown from the welding arc. Wear oil
free protective garments such as leather gloves, heavy shirt,
cuffless trousers, high shoes and a cap over your hair. Wear
ear plugs when welding out of position or in confined places.
Always wear safety glasses with side shields when in a
welding area.
6.g. Connect the work cable to the work as close to the welding
area as practical. Work cables connected to the building
framework or other locations away from the welding area
increase the possibility of the welding current passing
through lifting chains, crane cables or other alternate cir-
cuits. This can create fire hazards or overheat lifting chains
or cables until they fail.
6.h. Also see item 1.c.
6.I. Read and follow NFPA 51B Standard for Fire Prevention
During Welding, Cutting and Other Hot Work, available
from NFPA, 1 Batterymarch Park, PO box 9101, Quincy, Ma
022690-9101.
6.j. Do not use a welding power source for pipe thawing.
Jan ‘09
Refer to http://www.lincolnelectric.com/safety for additional safety information.
Mar. ‘93
iv
SAFETY
iv
PRÉCAUTIONS DE SÛRETÉ
Pour votre propre protection lire et observer toutes les instructions
et les précautions de sûreté specifiques qui parraissent dans ce
manuel aussi bien que les précautions de sûreté générales suiv-
antes:
Sûreté Pour Soudage A L’Arc
1. Protegez-vous contre la secousse électrique:
a. Les circuits à l’électrode et à la piéce sont sous tension
quand la machine à souder est en marche. Eviter toujours
tout contact entre les parties sous tension et la peau nue
ou les vétements mouillés. Porter des gants secs et sans
trous pour isoler les mains.
b. Faire trés attention de bien s’isoler de la masse quand on
soude dans des endroits humides, ou sur un plancher
metallique ou des grilles metalliques, principalement dans
les positions assis ou couché pour lesquelles une grande
partie du corps peut être en contact avec la masse.
c. Maintenir le porte-électrode, la pince de masse, le câble
de soudage et la machine à souder en bon et sûr état
defonctionnement.
d.Ne jamais plonger le porte-électrode dans l’eau pour le
refroidir.
e. Ne jamais toucher simultanément les parties sous tension
des porte-électrodes connectés à deux machines à souder
parce que la tension entre les deux pinces peut être le
total de la tension à vide des deux machines.
f. Si on utilise la machine à souder comme une source de
courant pour soudage semi-automatique, ces precautions
pour le porte-électrode s’applicuent aussi au pistolet de
soudage.
2. Dans le cas de travail au dessus du niveau du sol, se protéger
contre les chutes dans le cas ou on recoit un choc. Ne jamais
enrouler le câble-électrode autour de n’importe quelle partie
du corps.
3. Un coup darc peut être plus sévère qu’un coup de soliel,
donc:
a. Utiliser un bon masque avec un verre filtrant approprié
ainsi qu’un verre blanc afin de se protéger les yeux du ray-
onnement de l’arc et des projections quand on soude ou
quand on regarde l’arc.
b. Porter des vêtements convenables afin de protéger la
peau de soudeur et des aides contre le rayonnement de
l‘arc.
c. Protéger lautre personnel travaillant à proximité au
soudage à l’aide d’écrans appropriés et non-inflammables.
4. Des gouttes de laitier en fusion sont émises de larc de
soudage. Se protéger avec des vêtements de protection libres
de l’huile, tels que les gants en cuir, chemise épaisse, pan-
talons sans revers, et chaussures montantes.
5. Toujours porter des lunettes de sécuri dans la zone de
soudage. Utiliser des lunettes avec écrans lateraux dans les
zones où l’on pique le laitier.
6. Eloigner les matériaux inflammables ou les recouvrir afin de
prévenir tout risque d’incendie dû aux étincelles.
7. Quand on ne soude pas, poser la pince à une endroit isolé de
la masse. Un court-circuit accidental peut provoquer un
échauffement et un risque d’incendie.
8. S’assurer que la masse est connectée le plus prés possible
de la zone de travail qu’il est pratique de le faire. Si on place
la masse sur la charpente de la construction ou dautres
endroits éloignés de la zone de travail, on augmente le risque
de voir passer le courant de soudage par les chaines de lev-
age, câbles de grue, ou autres circuits. Cela peut provoquer
des risques d’incendie ou d’echauffement des chaines et des
câbles jusqu’à ce qu’ils se rompent.
9. Assurer une ventilation suffisante dans la zone de soudage.
Ceci est particuliérement important pour le soudage de tôles
galvanisées plombées, ou cadmiées ou tout autre métal qui
produit des fumeés toxiques.
10. Ne pas souder en présence de vapeurs de chlore provenant
dopérations de dégraissage, nettoyage ou pistolage. La
chaleur ou les rayons de l’arc peuvent réagir avec les vapeurs
du solvant pour produire du phosgéne (gas fortement toxique)
ou autres produits irritants.
11. Pour obtenir de plus amples renseignements sur la sûreté,
voir le code Code for safety in welding and cutting CSA
Standard W 117.2-1974.
PRÉCAUTIONS DE SÛRETÉ POUR
LES MACHINES À SOUDER À
TRANSFORMATEUR ET À
REDRESSEUR
1. Relier à la terre le chassis du poste conformement au code de
l’électricité et aux recommendations du fabricant. Le dispositif
de montage ou la piece à souder doit être branché à une
bonne mise à la terre.
2. Autant que possible, I’installation et l’entretien du poste seront
effectués par un électricien qualifié.
3. Avant de faires des travaux à l’interieur de poste, la debranch-
er à l’interrupteur à la boite de fusibles.
4. Garder tous les couvercles et dispositifs de sûreté à leur
place.
vv
TThhaannkk YYoouu
for selecting a QUALITY product by Lincoln Electric. We want you
to take pride in operating this Lincoln Electric Company product
••• as much pride as we have in bringing this product to you!
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it
handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection.
The level of seriousness to be applied to each is explained below:
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or loss of life.
This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment.
CAUTION
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims
for material damaged in shipment must be made by the purchaser against the transportation company at the
time the shipment is received.
Please record your equipment identification information below for future reference. This information can be
found on your machine nameplate.
Product _________________________________________________________________________________
Model Number ___________________________________________________________________________
Code Number or Date Code_________________________________________________________________
Serial Number____________________________________________________________________________
Date Purchased___________________________________________________________________________
Where Purchased_________________________________________________________________________
Whenever you request replacement parts or information on this equipment, always supply the information you
have recorded above. The code number is especially important when identifying the correct replacement parts.
On-Line Product Registration
- Register your machine with Lincoln Electric either via fax or over the Internet.
• For faxing: Complete the form on the back of the warranty statement included in the literature packet
accompanying this machine and fax the form per the instructions printed on it.
• For On-Line Registration: Go to our
WEB SITE at www.lincolnelectric.com. Choose “Quick Links” and then
“Product Registration”. Please complete the form and submit your registration.
CUSTOMER ASSISTANCE POLICY
The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equip-
ment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln
Electric for advice or information about their use of our products. We respond to our customers based on the best information in our posses-
sion at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such infor-
mation or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customer’s particular purpose,
with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or
correcting any such information or advice once it has been given, nor does the provision of information or advice create, expand or alter any
warranty with respect to the sale of our products.
Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control
of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in
applying these types of fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com
for any updated information.
vi
TABLE OF CONTENTS
Page
Installation.......................................................................................................................Section A
Technical Specifications.......................................................................................................A-1
Safety Precautions........................................................................................................A-2
Machine Grounding.......................................................................................................A-2
Spark Arrester...............................................................................................................A-2
Towing...........................................................................................................................A-2
Pre-Operation Engine Service..............................................................................................A-3
Fuel ...............................................................................................................................A-3
Oil..................................................................................................................................A-3
Battery Connections......................................................................................................A-3
Welding Cable Connections..........................................................................................A-3
Angle of Operation ........................................................................................................A-4
Lifting.............................................................................................................................A-4
High Altitude Operation.................................................................................................A-4
Location and Ventilation................................................................................................A-4
Stacking ........................................................................................................................A-4
Connection of Wire Feeders .........................................................................................A-4
Connection of TIG Module............................................................................................A-5
Additional Safety Precautions,Welding Operation Output.............................................A-5
Auxiliary Power Receptacles, and Plugs ......................................................................A-5,A-6
Motor Starting and Extension Cord Length Table................................................................A-6
Electrical Device Used with the Ranger 10,000 ...................................................................A-7
Auxiliary Power While Welding, Standby Power Connections............................................A-8
Premises Wiring ...................................................................................................................A-9
________________________________________________________________________________
Operation.........................................................................................................................Section B
Safety Precautions ...............................................................................................................B-1
General Description..............................................................................................................B-1
Welder Controls Function and Operation.............................................................................B-1
Range and Control Switch....................................................................................................B-2
Start in/Shutdown Instructions.....................................................................................................B-3
Starting the Engine........................................................................................................B-3
Safety Precautions........................................................................................................B-3
Stopping the Engine......................................................................................................B-3
Break-In Period .............................................................................................................B-3
Welding Process ..................................................................................................................B-4
Stick (Constant Current) Welding..................................................................................B-4
TIG (Constant Current) Welding ...................................................................................B-4
Wire Feed Welding Processes .....................................................................................B-4
Arc Gouging ..................................................................................................................B-4
Summary of Welding Processes and Current Ranges for Tungsten Electrodes ..........B-5
________________________________________________________________________________
Accessories ........................................................................................................Section C
Optional Equipment...............................................................................................C-1
Recommended Equipment....................................................................................C-1
________________________________________________________________________
Maintenance ....................................................................................................Section D
Safety Precautions ................................................................................................D-1
Routine Engine Maintenance ..........................................................................D-1,D2
Engine Adjustments...............................................................................................D-3
Slip Rings ..............................................................................................................D-3
Battery Maintenance.......................................................................................D-3
Engine Maintenance Parts..............................................................................D-3
________________________________________________________________________
Troubleshooting..............................................................................................Section E
How to Use Troubleshooting Guide.......................................................................E-1
Troubleshooting Guide...................................................................................E-2, E-3
________________________________________________________________________
Wiring Diagrams & Dimension Print..............................................................Section F
Wiring and Connection Diagrams....................................................................F-1,F-2
Dimension Print......................................................................................................F-3
________________________________________________________________________
Parts List.................................................................................................................P-488
________________________________________________________________________
vi
A-1
INSTALLATION
EAGLE™ 10,000
A-1
TECHNICAL SPECIFICATIONS - EAGLE™ 10,000 (K2343-2 )
INPUT - GASOLINE ENGINE
RATED OUTPUT @ 104°F (40°C) - WELDER
HEIGHT WIDTH DEPTH WEIGHT
30.3 in. 19.1 in. 42.3 in.
770 mm 485 mm 1074 mm 502 lbs. (228kg)
RATED OUTPUT @ 104°F (40°C) - GENERATOR
Welding Output
DC Constant Current 210A / 25V / 100%
Auxiliary Power
1
10,500 Watts Peak, 60 Hz AC
9,000 Watts Continuous, 60 Hz AC
120/240 Volts
PHYSICAL DIMENSIONS
Make/Model
Kohler
CH23S
Description
2 cylinder
4 Cycle
Air-Cooled
Gasoline
Engine.
Aluminum Alloy
with Cast Iron
Liners,
Electronic Start
Operating
Speed (RPM)
High Idle 3700
Full Load 3500
Low Idle 2200
Displacement
cu. in.
(cu.cm.)
41(674)
Kohler
Capacities
Fuel:
9 Gal (34 L)
Lubricating Oil:
2.0 Qts. (1.9 L)
Horsepower
23 HP @
3600 RPM
(Kohler)
Starting
System
12VDC
Battery
Electric Start
Group 58
Battery
(435 cold
Cranking
Amps)
1. Output rating in watts is equivalent to volt - amperes at unity factor.Output voltage is within +/-10% at all loads up to rated capacity.
When welding available auxiliary power will be reduced.
A-2
INSTALLATION
EAGLE™ 10,000
A-2
SAFETY PRECAUTIONS
MACHINE GROUNDING
Because this portable engine driven welder or genera-
tor creates it’s own power, it is not necessary to con-
nect it’s frame to an earth ground, unless the machine
is connected to premises wiring (your home, shop,
etc.).
To prevent dangerous electric shock, other equip-
ment to which this engine driven welder supplies
power must:
be grounded to the frame of the welder using a
grounded type plug, or be double insulated.
Do not ground the machine to a pipe that carries
explosive or combustible material.
------------------------------------------------------------------------
When this welder is mounted on a truck or trailer, it’s
frame must be electrically bonded to the metal frame
of the vehicle. Use a #8 or larger copper wire connect-
ed between the machine grounding stud and the
frame of the vehicle.
Where this engine driven welder is connected to
premises wiring such as that in your home or shop, it’s
frame must be connected to the system earth ground.
See further connection instructions in the section enti-
tled “Standby Power Connections”, as well as the arti-
cle on grounding in the latest National Electrical Code
and the local code.
In general, if the machine is to be grounded, it should
be connected with a #8 or larger copper wire to a solid
earth ground such as a metal water pipe going into
the ground for at least ten feet and having no insulat-
ed joints, or to the metal framework of a building
which has been effectively grounded. The National
Electrical Code lists a number of alternate means of
grounding electrical equipment. A machine grounding
stud marked with the symbol is provided on the
front of the welder.
SPARK ARRESTER
Some federal, state, or local laws may require that
gasoline engines be equipped with exhaust spark
arresters when they are operated in certain locations
where unarrested sparks may present a fire hazard.
The standard muffler included with this welder does
not qualify as a spark arrester. When required by local
regulations, the K894-1 spark arrester must be
installed and properly maintained.
An incorrect arrester may lead to damage to the
engine or adversely affect performance.
------------------------------------------------------------------------
TOWING
The recommended trailer for use with this equipment
for road, in-plant and yard towing by a vehicle
(1)
is
Lincolns K957-1. If the user adapts a non-Lincoln
trailer, he must assume responsibility that the method
of attachment and usage does not result in a safety
hazard nor damage the welding equipment. Some of
the factors to be considered are as follows:
1. Design capacity of trailer vs. weight of Lincoln
equipment and likely additional attachments.
2. Proper support of, and attachment to, the base of
the welding equipment so there will be no undue
stress to the framework.
CAUTION
Do not attempt to use this equipment until you
have thoroughly read the engine manufacturer’s
manual supplied with your welder. It includes
important safety precautions, detailed engine
starting, operating and maintenance instructions,
and parts lists.
------------------------------------------------------------------------
ELECTRIC SHOCK can kill.
Do not touch electrically live parts or
electrode with skin or wet clothing.
Insulate yourself from work and
ground
• Always wear dry insulating gloves.
------------------------------------------------------------------------
ENGINE EXHAUST can kill.
Use in open, well ventilated areas or
vent exhaust outside.
------------------------------------------------------------------------
MOVING PARTS can injure.
Do not operate with doors open or
guards off.
• Stop engine before servicing.
• Keep away from moving parts.
------------------------------------------------------------------------
See additional warning information at
front of this operators manual.
-----------------------------------------------------------
WARNING
WARNING
3. Proper placement of the equipment on the trailer to
insure stability side to side and front to back when
being moved and when standing by itself while
being operated or serviced.
4. Typical conditions of use, i.e., travel speed; rough-
ness of surface on which the trailer will be operated;
environmental conditions.
5. Conformance with federal, state and local laws
(1)
(1) Consult applicable federal, state and local laws regarding specific
requirements for use on public highways.
READ the engine operating and maintenance
instructions supplied with this machine.
FUEL
Fil the fuel tank with clean, fresh, lead-free gasoline. Observe fuel
gauge while filling to prevent overfilling.
A-3
INSTALLATION
EAGLE™ 10,000
A-3
BATTERY CONNECTIONS
Use caution as the electrolyte is a strong acid that can
burn skin and damage eyes.
------------------------------------------------------------------------
This welder is shipped with the negative battery cable disconnected.
Make sure that the Engine Switch is in the “OFF position and
attach the disconnected cable securely to the negative battery ter-
minal before attempting to operate the machine. If the battery is dis-
charged and does not have enough power to start the engine, see
the battery charging instructions in the Battery section.
NOTE: This machine is furnished with a wet charged battery; if
unused for several months, the battery may require a booster
charge. Be careful to charge the battery with the correct polarity.
WELDING OUTPUT CABLES
With the engine off, connect the electrode and work cables to the
studs provided. These connections should be checked periodically
and tightened if necessary. Loose connections will result in over-
heating of the output studs.
When welding at a considerable distance from the welder, be sure
you use ample size welding cables. Listed below are copper cable
sizes recommended for the rated current and duty cycle. Lengths
stipulated are the distance from the welder to work and back to the
welder again. Cable sizes are increased for greater lengths primari-
ly for the purpose of minimizing cable voltage drop.
TOTAL COMBINED LENGTH OF
ELECTRODE AND WORK CABLES
0-100 Ft.
(0-328 m)
100-200 Ft.
(328-656 m)
200-250 Ft.
(656-820 m)
225 Amps
100% Duty Cycle
1 AWG
1 AWG
1/0 AWG
• Damage to the fuel tank may cause
fire or explosion. Do not
drill holes
in the EAGLE™ 10,000 base or weld
to
the EAGLE™ 10,000 base.
WARNING
CAUTION
OIL
The EAGLE 10,000 is shipped with the engine
crankcase filled with SAE 10W-30 oil. Check the oil
level before starting the engine. If it is not up to the full
mark on the dip stick, add oil as required. Make certain
that the oil filler cap is tightened securely. Refer to the
engine Owner’s Manual for specific oil recommenda-
tions.
LUBRICATION SYSTEM CAPACITY
(INCLUDING FILTER)
Kohler CH23S - 2.0 Quarts (1.9 Liters)
VEHICLE MOUNTING
Improperly mounted concentrated loads may cause unstable
vehicle handling and tires or other components to fail.
• Only transport this Equipment on serviceable vehicles which
are rated and designed for such loads.
• Distribute, balance and secure loads so vehicle is stable
under conditions of use.
• Do not exceed maximum rated loads for components such as
suspension, axles and tires.
• Mount equipment base to metal bed or frame of vehicle.
• Follow vehicle manufacturer’s instructions.
------------------------------------------------------------------------
WARNING
• Stop engine while fueling.
• Do not smoke when fueling.
• Keep sparks and flame away from
tank.
• Do not leave unattended while fuel-
ing.
• Wipe up spilled fuel and allow fumes
to clear before starting engine.
• Do not overfill tank, fuel expansion
may cause overflow.
GASOLINE FUEL ONLY
------------------------------------------------------------------------
WARNING
GASOLINE
can cause fire
or explosion.
A-4
INSTALLATION
EAGLE™ 10,000
A-4
ANGLE OF OPERATION
Internal combustion engines are designed to run in a
level condition which is where the optimum perfor-
mance is achieved. The maximum angle of operation
for the engine is 15 degrees from horizontal in any
direction. If the engine is to be operated at an angle,
provisions must be made for checking and maintain-
ing the oil at the normal (FULL) oil capacity in the
crankcase in a level condition.
When operating at an angle, the effective fuel capaci-
ty will be slightly less than the specified 9 gal (34 L).
LIFTING
The EAGLE™ 10,000 weighs approximately 575 lbs.
(281kg) with a full tank of gasoline. A lift bail is
mounted to the machine and should always be used
when lifting the machine.
ADDITIONAL SAFETY PRECAUTIONS
• Lift only with equipment of adequate
lifting capacity.
• Be sure machine is stable when lift-
ing.
• Do not lift this machine using lift bail
if it is equipped with a heavy acces-
sory such as trailer or gas cylinder.
FALLING • Do not lift machine if lift bail is
EQUIPMENT can damaged.
cause injury. • Do not operate machine while
suspended from lift bail.
-----------------------------------------------------------------------
HIGH ALTITUDE OPERATION
At higher altitudes, Welder output de-rating may be neces-
sary.
For maximum rating, de-rate the welder output 3.5% for
every 1000ft. (305m) above 3000ft. (914m).
If operation will consistently be at altitudes above 5,000 ft.
(1525m), a carburetor jet designed for high altitudes should
be installed. This will result in better fuel economy, cleaner
exhaust and longer spark plug life. It will not give increased
power. Contact your local authorized engine service shop
for high altitude jet kits that are available from the engine
manufacturer.
Do not operate with a high altitude jet installed at alti-
tudes below 5000 ft. This will result in the engine run-
ning too lean and result in higher engine operating
temperatures which can shorten engine life.
Contact your local Kohler Authorized Dealer for high altitude
jet kits that are available from the engine manufacturer.
Muffler Relocation
Shut off welder and allow muffler to cool before touch-
ing muffler.
------------------------------------------------------------------------
The EAGLE™ 10,000 is shipped with the exhaust coming
out on the left side. The exhaust can be changed to the
opposite side by removing the two screws that hold the
exhaust port cover in place and installing the cover on the
opposite side. (Operating the EAGLE™ 10,000 without the
cover in place will result in a higher noise level and no
increase in machine output.)
LOCATION / VENTILATION
The welder should be located to provide an unrestricted flow
of clean, cool air to the cooling air inlets and to avoid heated
air coming out of the welder recirculating
back to the cooling air inlet. Also, locate the welder so that
engine exhaust fumes are properly vented to an outside
area.
STACKING
EAGLE™ 10,000 machines cannot be stacked.
CONNECTION OF LINCOLN ELECTRIC
WIRE FEEDERS
Note: A constant voltage (CV) power source is recommend-
ed for wire feeder applications. The LN-15 and LN-25
may be used with a constant current (CC) power
source, such as the EAGLE™ 10,000, for non-critical
applications where weld quality and deposition prop-
erties are not critical.
Shut off welder before making any electrical connec-
tions.
------------------------------------------------------------------------
WIRE FEED CONNECTION OF LN-15 ACROSS-THE-ARC
WIRE FEEDER
The LN-15 has an internal contactor and the electrode is not
energized until the gun trigger is closed. When the gun trig-
ger is closed the wire will begin to feed and the welding
process is started.
a. Shut the welder off.
b. For electrode Positive, connect the electrode cable to
the "+" terminal of the welder and work cable to the "-"
terminal of the welder. For electrode Negative, connect
the electrode cable "-" terminal of the welder and work
cable to the "+" terminal of the welder.
CAUTION
WARNING
WARNING
WARNING
A-5
INSTALLATION
EAGLE™ 10,000
A-5
INSTRUCTIONS
ADDITIONAL SAFETY PRECAUTIONS
Always operate the welder with the roof and case
sides in place as this provides maximum protection
from moving parts and assures proper cooling air flow.
Read and understand all Safety Precautions before
operating this machine. Always follow these and any
other safety procedures included in this manual and in
the Engine Owner’s Manual.
WELDER OPERATION
WELDER OUTPUT
• Maximum Open Circuit Voltage at 3700 RPM is
80 Volts RMS.
• Duty Cycle is the percentage of time the load is
being applied in a 10 minute period. For example, a
60% duty cycle represents 6 minutes of load and 4
minutes of no load in a 10 minute period. Duty Cycle
for the EAGLE™ 10,000 is 100%.
AUXILIARY POWER
The EAGLE™ 10,000 can provide, up to 10,500 watts
of 120/240 volts AC, single phase 60Hz power peak
use and up to 9,000 watts of 120/240 volts AC, single
phase 60Hz power for continuous use. The front of
the machine includes three receptacles for connecting
the AC power plugs; one 50 amp 120/240 volt NEMA
14-50R receptacle and two 20 amp 120 volt NEMA 5-
20R receptacles. Output voltage is within +/-10% at all
loads up to rated capacity. All auxiliary power is pro-
tected by circuit breakers.
Do not connect any plugs that connect to the
power receptacles in parallel.
------------------------------------------------------------------------
Start the engine and set the “IDLER” control switch to
the desired operating mode. Set the CONTROL” to
10. Voltage is now correct at the receptacles for auxil-
iary power.
c. Attach the single lead from the front of the LN-15
to work using the spring clip at the end of the lead.
This is a control lead to supply current to the wire
feeder motor; it does not carry welding current.
d. Set the “RANGE” switch to a suitable position.
e. Place the Engine switch in the “Auto Idle” position.
f. Set the Welding Mode on the LN-15 to the “CC” mode.
g. Adjust the wire feed speed at the LN-15 and adjust
the welding current with the output “CONTROL” at
the welder.
Output “CONTROL” must be set above 3.
Note: LN-15 Control Cable model will not work with
the EAGLE™ 10,000.
CONNECTION OF THE LN-25 TO THE
EAGLE™ 10,000
a. Shut the welder off.
b. For electrode Positive, connect the electrode
cable from the LN-25 to the "+" terminal of the
welder and work cable to the "-" terminal of the
welder. For electrode Negative, connect the elec-
trode cable from the LN-25 to the "-" terminal of
the welder and work cable to the "+" terminal of
the welder.
c. Position the “RANGE” switch to a suitable posi-
tion.
d. Attach the single lead from the LN-25 control box
to the work using the spring clip on the end of the
lead - it carries no welding current.
e. Place the engine switch in the “AUTO IDLE” posi-
tion.
f. Set the Wire Feed Mode switch on the LN-25 to
the “CC” mode.
g. Adjust wire feed speed at the LN-25 and adjust
the welding current with the output CONTROL
at the welder.
Note: The welding electrode is energized at all
times, unless an LN-25 with built-in contactor
is used. If the output CONTROL is set
below “3”, the LN-25 contactor may not pull
in.
CONNECTION OF K930-2 TIG MODULE TO THE
EAGLE™ 10,000.
The TIG Module is an accessory that provides high
frequency and shielding gas control for AC and DC
GTAW (TIG) welding. The EAGLE10,000 cannot
weld in AC, but the K930-2 will allow for high frequen-
cy starting and with the K938-1 contactor option, a
cold TIG Torch. See IM528 supplied with the TIG
Module for installation instructions.
Note: The TIG Module does not require the use of a
high frequency bypass capacitor. However, if
the EAGLE™ 10,000 is used with any other
high frequency equipment, the bypass capaci-
tor must be installed, order kit T12246.
EAGLE™ 10,000
Constant Current 210 Amps DC @ 25 Volts
CAUTION
A-6
INSTALLATION
EAGLE™ 10,000
A-6
120 V DUPLEX RECEPTACLES
The 120V auxiliary power receptacles should only be
used with three wire grounded type plugs or approved
double insulated tools with two wire plugs.
The current rating of any plug used with the system
must be at least equal to the current load through the
associated receptacle.
MOTOR STARTING
Most 1.5 hp AC single phase motors can be started if
there is no load on the motor or other load connected
to the machine, since the full load current rating of a
1.5 hp motor is approximately 20 amperes (10
amperes for 240 volt motors). The motor may be run
at full load when plugged into only one side of the
duplex receptacle. Larger motors through 2 hp can be
run provided the receptacle rating as previously stated
is not exceeded. This may necessitate 240V operation
only.
GND
120 V
120 V*
240 V
*Current Sensing for Automatic Idle.
(Receptacle viewed from front of Machine)
EAGLE™ 10,000 Extension Cord Length Recommendations
(Use the shortest length extension cord possible sized per the following table.)
Current
(Amps)
15
20
15
20
38
Voltage
Volts
120
120
240
240
240
Load
(Watts)
1800
2400
3600
4800
9000
30
60
(9)
(18)
40
30
75
60
(12)
(9)
(23)
(18)
75
50
150
100
50
(23)
(15)
(46)
(30)
(15)
125
88
225
175
90
(38)
(27)
(69)
(53)
(27)
175
138
350
275
150
(53)
(42)
(107)
(84)
(46)
300
225
600
450
225
(91)
(69)
(183)
(137)
(69)
Maximum Allowable Cord Length in ft. (m) for Conductor Size
Conductor size is based on maximum 2.0% voltage drop.
14 AWG 12 AWG 10 AWG 8 AWG 6 AWG 4 AWG
120/240 VOLT DUAL VOLTAGE RECEPTACLE
The 120/240 volt receptacle can supply up to 38 amps
of 240 volt power to a two wire circuit, up to 38 amps
of 120 volts power from each side of a three wire cir-
cuit (up to 76 amps total). Do not connect the 120 volt
circuits in parallel. Current sensing for the automatic
idle feature is only in one leg of the three wire circuit
as shown in the following column.
A-7
INSTALLATION
EAGLE™ 10,000
A-7
TABLE lll
ELECTRICAL DEVICE USE WITH THE EAGLE™ 10,000.
Type Common Electrical Devices Possible Concerns
Resistive Heaters, toasters, incandescent NONE
light bulbs, electric range, hot
pan, skillet, coffee maker.
Capacitive TV sets, radios, microwaves, Voltage spikes or high voltage
appliances with electrical control. regulation can cause the capac-
itative elements to fail. Surge
protection, transient protection,
and additional loading is recom-
mended for 100% fail-safe
operation. DO NOT RUN
THESE DEVICES WITHOUT
ADDITIONAL RESISTIVE TYPE
LOADS.
Inductive Single-phase induction motors, These devices require large
drills, well pumps, grinders, small current inrush for starting.
refrigerators, weed and hedge Some synchronous motors may
trimmers be frequency sensitive to attain
maximum output torque, but
they SHOULD BE SAFE from
any frequency induced failures.
Capacitive/Inductive Computers, high resolution TV sets, An inductive type line condition-
complicated electrical equipment. er along with transient and
surge protection is required,
and liabilities still exist. DO
NOT USE THESE DEVICES
WITH A EAGLE™ 10,000
The Lincoln Electric Company is not responsible for any damage to electrical components improperly connect-
ed to the EAGLE™ 10,000.
A-8
INSTALLATION
EAGLE™ 10,000
A-8
STANDBY POWER CONNECTIONS
The EAGLE™ 10,000 is suitable for temporary, stand-
by, or emergency power using the engine manufactur-
er’s recommended maintenance schedule.
The EAGLE™ 10,000 can be permanently installed as
a standby power unit for 240V-3 wire, single phase 38
ampere service.
(Connections must be made by a licensed electri-
cian who can determine how the 120/240V power
can be adapted to the particular installation and
comply with all applicable electrical codes.) The
following information can be used as a guide by
the electrician for most applications (refer also to
the connection diagram shown in Figure 1.)
------------------------------------------------------------------------
1. Install a double pole, double throw switch between
the power company meter and the premises
disconnect.
Switch rating must be the same or greater than
the customer’s premises disconnect and service
overcurrent protection.
2. Take necessary steps to assure load is limited to
the capacity of the EAGLE™ 10,000 by installing a
38 amp 240V double pole circuit breaker.
Maximum rated load for the 240V auxiliary is 38
amperes. Loading above 38 amperes will reduce
output voltage below the allowable -10% of rated
voltage which may damage appliances or other
motor-driven equipment.
3. Install a 50 amp 120/240V plug (NEMA type 14-50)
to the Double Pole Circuit Breaker using No. 8,
4 conductor cable of the desired length. (The
50 amp 120/240V plug is available in the
optional plug kit.)
4. Plug this cable into the 50 amp 120/240V
receptacle on the EAGLE™ 10,000 case front.
WARNING
AUXILIARY POWER WHILE WELDING
Simultaneous welding and power loads are permitted
by following Table I. The permissible currents shown
assume that current is being drawn from either the
120V or 240V supply (not both at the same time).
Also, the “Output Control” is set at “10” for maximum
auxiliary power.
TABLE I
SIMULTANEOUS WELDING AND POWER
Output Selector Permissible Power Permissible Auxiliary
Setting Watts (Unity Power Current in Amperes
Factor) @ 120V
*-or- @ 240V
Max. Stick or Wire
Feed Setting None 00
145 Stick Setting 3950 32 16
90 Stick Setting 6000 50
** 25
NO WELDING 9000 76
** 38
* Each duplex receptacle is limited to 20 amps.
**Not to exceed 40A per 120VAC branch circuit when
splitting the 240 VAC output.
240 Volt
60 Hz.
3-Wire
Service
POWER
COMPANY
METER
240 VOLT
120 VOLT
120 VOLT
LOAD
N
NEUTRAL
BUS
GROUND
P
REMISES
DISCONNECT AND
S
ERVICE
OVERCURRENT
P
ROTECTION
GND
N
NOTE: No. 6 COPPER CONDUCTOR CABLE SEE
NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE
SIZE RECOMMENDATIONS.
240 VOLT
G
ROUNDED CONDUCTOR
4
0 AMP
240 VOLT
DOUBLE
POLE
CIRCUIT
BREAKER
DOUBLE POLE DOUBLE THROW
SWITCH RATING TO BE THE SAME
A
S OR GREATER THAN PREMISES
SERVICE OVERCURRENT
PROTECTION.
50 AMP, 120/240
VOLT PLUG
NEMA TYPE 14-50
50 AMP, 120/240 VOLT
RECEPTACLE
A-9
INSTALLATION
EAGLE™ 10,000
A-9
Connection of EAGLE™ 10,000 to premises wiring
must be done by a licensed electrician and must
comply with the National Electrical Code and all
other applicable electrical codes.
Figure 1
CONNECTION OF EAGLE™ 10,000 TO PREMISES WIRING
WARNING
WELDER CONTROLS - FUNCTION AND
OPERATION
ENGINE SWITCH
The engine switch is used to Start the Engine, Select
High Idle or Auto Idle while the engine is running, and
stop the Engine.
When placed in the “OFF” position, the ignition
circuit is de-energized to shut down the engine.
When held in the “START” position, the engine
starter motor is energized.
When in “HIGH IDLE” ( ) position, the engine will
run continuously at high idle.
When in “AUTO IDLE” ( / ) position, the
engine will run continuously and the idler operates as
follows:
Welding
When the electrode touches the work, the welding
arc is initiated and the engine accelerates to full
speed.
After welding ceases (and no auxiliary power is
being drawn), the engine will return to low idle
after approximately 10 to 14 seconds.
Auxiliary Power
With the engine running at low idle and auxiliary
power for lights or tools is drawn (approximately
100-150 watts or greater) from the receptacles,
the engine will accelerate to high speed. If no
power is being drawn from the receptacles (and
not welding) for 10-14 seconds, the idler reduces
the engine speed to low idle.
B-1
OPERATION
EAGLE™ 10,000
B-1
SAFETY PRECAUTIONS
Do not attempt to use this equipment until you
have thoroughly read the engine manufacturer’s
manual supplied with your welder. It includes
important safety precautions, detailed engine
starting, operating and maintenance instructions,
and parts lists.
------------------------------------------------------------------------
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or
electrode with skin or wet clothing.
• Insulate yourself from work and
ground
• Always wear dry insulating gloves.
• Always operate the welder with the hinged door
closed and the side panels in place.
• Read carefully the Safety Precautions page
before operating this machine. Always follow
these and any other safety procedures included
in this manual and in the Engine Instruction
Manual.
------------------------------------------------------------------------
GENERAL DESCRIPTION
The EAGLE
10,000 is a twin-cylinder, gasoline dri-
ven, multiprocess arc welder and AC power genera-
tor. It is built in a heavy gauge steel case for durability
on the job site.
RANGE” SWITCH
Never change the “RANGE” Switch setting while
welding. This will damage the switch.
------------------------------------------------------------------------
CONTROL” DIAL
Provides a fine welding current adjustment within the
Range Switch settings.
B-2
OPERATION
B-2
EAGLE™ 10,000
CAUTION
KOHLER
23 H.P. COMMAND
.39 Gallons/Hour
(1.49 Liters/Hour)
.74 Gallons/Hour
(2.79 Liters/Hour)
1.29 Gallons/Hour
(4.87 Liters/Hour)
1.40 Gallons/Hour)
(5.31 Liters/Hour)
Low Idle - No Load
2200 RPM
High Idle - No Load
3700 RPM
DC CC Weld Output
210 Amps @ 25 Volts
Auxiliary Power
9000 Watts
EAGLE™ 10,000 APPROXIMATE FUEL CONSUMPTION
Process Range Setting Current Range
STICK/TIG
(constant current)
(3 range settings)
90 Max.
145 Max.
210 Max.
50 to 90 Amps
70 to 145 Amps
120 to 210 Amps
B-3
OPERATION
B-3
STARTING/SHUTDOWN INSTRUCTIONS
STARTING THE ENGINE
Be sure all Pre-Operation Maintenance has been per-
formed. Also, read the Engine Owner’s Manual before
starting for the frist time.
Remove all loads connected to the AC power recepta-
cles. Use the choke control as follows:
KOHLER ENGINE - Always pull the choke control out
when starting the engine; cold, warm or hot.
Turn the engine switch to the “start” position and
crank the engine until it starts. Release the switch as
soon as the engine starts, slowly return the choke
control to the full “in” position (choke open),
and turn the switch to the Auto Idle( / )
position. Do not turn the switch to the “start” position
while the engine is running because this will cause
damage to the ring gear and/or starter motor
After running at high engine speed for 10-14 seconds,
the engine will go to low idle.
Allow the engine to warm up by letting it run at low idle
for a few minutes.
STOPPING THE ENGINE
Remove all welding and auxiliary power loads and
allow engine to run at low idle speed for a few minutes
to cool the engine.
Stop the engine by placing the Engine switch in the
“OFF” position.
A fuel shut off valve is not required on the EAGLE
10,000 because the fuel tank is mounted below the
engine.
BREAK-IN PERIOD
It is normal for any engine to use a greater amount of
oil until the break-in is accomplished. Check the oil
level twice a day during the break-in period (approxi-
mately 50 running hours).
IMPORTANT: IN ORDER TO ACCOMPLISH THIS
BREAK-IN, THE UNIT SHOULD BE
SUBJECTED TO MODERATE
LOADS, WITHIN THE RATING OF
THE MACHINE. AVOID LONG IDLE
RUNNING PERIODS. REMOVE
LOADS AND ALLOW ENGINE TO
COOL BEFORE SHUTDOWN.
The engine manufacturer’s recommendation for the
running time until the first oil change is as follows:
The oil filter is to be changed at the second oil
change. Refer to the Engine Owners Manual or
Maintenance section of this manual for more informa-
tion.
EAGLE™ 10,000
• Do not touch electrically live parts
of electrode with skin or wet
clothing.
• Keep flammable material away.
• Insulate yourself from work and
ground. Wear eye, ear, and body
protection.
• Keep your head out of the fumes.
• Use ventilation or exhaust to
remove fumes from breathing zone.
WARNING
KOHLER
CH23S
5 HRS
ARC GOUGING
The EAGLE 10,000 can be used for limited arc
gouging.
Set the Range switch to adjust output current to the
desired level for the gouging electrode being used
according to the ratings in the following table:
B-4
OPERATION
B-4
WELDING PROCESS
For any electrodes the procedures should be kept
within the rating of the machine. For electrode infor-
mation see the appropriate Lincoln publication.
Stick (Constant Current) Welding
Connect welding cables to the +and -studs. Start
the engine. The “RANGEswitch markings indicate
the maximum current for that range as well as the typ-
ical electrode size for that range. The OUTPUT
Control provides fine adjustment of the welding cur-
rent within the select range. For maximum output with-
in a selected range set the “OUTPUT” Control at 10.
For minimum output within a selected range set the
“OUTPUT” Control at 5. (“OUTPUT” Control settings
below 5 may reduce arc stability) For best overall
welding performance set the “RANGE” Switch to the
lowest setting and the OUTPUT Control near the
maximum to achieve the desired welding current.
RANGE SETTING TYPICAL CURRENT RANGE
ELECTRODE SIZE
WIRE FEED WELDING PROCESSES
The Innershield
®
electrode recommended for use with
the EAGLE™ 10,000 is NR
®
-211-MP. The electrode
sizes and welding ranges that can be used with the
EAGLE™ 10,000 are shown in the following table:
The EAGLE 10,000 is recommended for limited
“MIG” welding (GMAW - gas metal arc welding). The
recommended electrodes are .030and .035 L-50
and L-56. They must be used with a blended shield-
ing gas such as C25 (75% Argon - 25% CO
2
). The
welding ranges that can be used with the EAGLE™
10,000 are shown in the following table:
EAGLE™ 10,000
Diameter Wire Speed Approximate
(in.) Range In./Min. Current Range
.035 80 - 110 75A to 120A
.045 70 - 130 120A to 170A
.068 40 - 90 125A to 210A
Diameter Wire Speed Approximate
(in.) Range In./Min. Current Range
.030 75 - 300 50A to 130A
.035 100 - 250 80A to 175A
90 MAX.
145 MAX.
210 MAX.
3/32
1/8
5/32
50 TO 90 AMPS
70 TO 145 AMPS
120 TO 210 AMPS
TIG (CONSTANT CURRENT) WELDING
The K930-[ ] TIG Module installed on a EAGLE
10,000 provides high frequency and shielding gas
control for GTAW (TIG) welding processes. Output
Control is from the EAGLE™ 10,000. The control on
the TIG Module is not functional. After flow time is
adjustable from 0 to 55 seconds. A K814 Arc Start
Switch is required.
The K930-[ ] TIG Module should be used with the
EAGLE™ 10,000 on HIGH IDLE to maintain satisfac-
tory operation. It can be used in the AUTO position
but the delay going to flow idle after welding is ceased
will be increased if the AFTER FLOW CONTROL is
set above 10 seconds. A K814 Arc Start Switch is
required.
Carbon Diameter
CURRENT RANGE (DC, electrode positive)
1/8 60 - 90 Amps
5/32 90 - 250 Amps
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35

Lincoln Electric Eagle 10,000 Mode d'emploi

Catégorie
Système de soudage
Taper
Mode d'emploi