This document contains information, which is protected by copyright. Reproduction, adaptation or
translation without prior permission is prohibited, except as allowed under the copyright laws.
Disclaimer
Leonton Technologies, Co. Ltd. provides this manual without warranty of any kind, expressed or implied,
including but not limited to the implied warranties of merchantability and fitness for a particular purpose.
Leonton Technologies, Co. Ltd. may make improvements and/or changes to the product and/or
specifications of the product described in this manual, without prior notice. Leonton Technologies, Co. Ltd.
will not be liable for any technical inaccuracies or typographical errors found in this guide. Changes are
periodically made to the information contained herein and will be incorporated into later versions of the
manual. The information contained is subject to change without prior notice.
FCC Notice
This equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant
to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy. It may cause harmful interference to radio communications if the equipment is not installed and
used in accordance with the instructions. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications not expressly approved by the grantee of this device could void
the user's authority to operate the equipment.
Déclaration FCC
Cet équipement a été testé et reconnu conforme aux limites de la classe A pour les équipements
numériques, conformément à la section 15 des Réglementations FCC. Ces limites sont conçues pour fournir
une protection raisonnable contre toutes interférences nuisibles dans un milieu résidentiel. Cet
équipement génère, utilise, et peut émettre de l’énergie de fréquence radio et, s’il n’est pas installé et
utilisé conformément au manuel d’instruction, peut perturber la réception radio. Cependant, il n’est pas
garanti que l’équipement ne produira aucune interférence dans une installation particulière. Si cet
équipement cause des interférences nuisibles à la réception radio ou télévisée, qui peuvent être
déterminées en l’éteignant et le rallumant, l’utilisateur est encouragé à essayer de remédier au problème
en prenant les mesures suivantes:
Réorienter ou déplacer l’antenne réceptrice.
Augmenter la distance entre l’équipement et le récepteur.
Connecter l’équipement à une prise secteur sur un circuit difrent de celui utilisé par le récepteur.
Consulter le négociant ou un technicien radio/TV expérimenté.
Attention: Tout changement ou modification non expressément approuvé par le concessionnaire de cet
appareil pourrait annuler l'autorité de l'utilisateur à utiliser l'équipement.
CE Mark Warning
This is a Class-A product. In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
CE Mark Avertissement
Ceci est un produit de classe A. Dans un environnement domestique, ce produit peut être utilisé en
présence d'interférences radio.
This document is the current official release manual. Please check our website (www.leonton.com) for
any updated manual or contact us by e-mail (sales@leonton.com).
CONTENT
OVERVIEW .................................................................................................................................... 1
Key Features .................................................................................................................................................................. 1
Package Contents ........................................................................................................................................................ 2
Safety Precaution ......................................................................................................................................................... 2
HARDWARE DESCRIPTION ....................................................................................................... 3
Physical Dimensions ................................................................................................................................................... 3
Front Panel ..................................................................................................................................................................... 4
Top View ......................................................................................................................................................................... 4
LED Indicators ............................................................................................................................................................... 5
PoE Port LED Indicators ............................................................................................................................................. 7
Relay Contact Alarm Warning .................................................................................................................................. 9
Ethernet Ports ............................................................................................................................................................. 10
Cabling .......................................................................................................................................................................... 11
Wiring the Power Inputs .......................................................................................................................................... 13
Wiring the Fault Alarm Contact ............................................................................................................................. 14
Grounding Note ......................................................................................................................................................... 14
MOUNTING INSTALLATION ................................................................................................... 15
DIN-Rail Mounting .................................................................................................................................................... 15
Wall Mounting ............................................................................................................................................................ 17
HARDWARE INSTALLATION ................................................................................................... 18
Installation Steps ....................................................................................................................................................... 18
TROUBLE SHOOTING ............................................................................................................... 20
1
OVERVIEW
This series is rated IP30 and installation by DIN Rail. Each unit of this industrial gigabit managed PoE
compact size design for short installation space provided 4*10/100/1000Base-Tx with IEEE 802.3bt
compliant ports (90W) convert to 2 dual-rate (100/1000) SFP slot, suitable for Ethernet and SFP
conversion applications.
In order to prevent unregulated voltage, this series provides high EFT and ESD protection. This also allows
it to function in harsh environments, as well as support power redundancy with a dual power input
design with reverse polarity protection.
With one model having an operating temperature of -10°C ~ 65°C , and another with a wide operating
temperature of -40°C ~ 75°C, this series is designed to meet any needs for industrial automation
application and harsh environments.
Key Features
Interface & Performance
Copper port support auto MDI/MDI-X function
Embedded 4*10/100/1000Base-T(X) with bt PoE-PSE (90W/Port) and 2*100/1000 SFP Slot
Store-and-forward switching architecture
8K MAC Address Table
Supports 9.6Kbytes Jumbo Frame
4Mbits memory buffer
Power Input
Dual 48-55VDC redundant power inputs, with SELV output certified by UL61010-2-201
1 removable 6-contact terminal block
Max. current 5.2A
Max. PoE output: 240W
For IEEE802.3bt applications, the power input not less than 53VDC is recommended
Certification
CE/FCC
UL 61010-1
UL 61010-2-201
Operating Temperature
Standard operating temperature model: -10°C ~ 65°C
Extended operating temperature model (-T): -40°C ~ 75°C
Case/Installation
IP30 protection (not certified by UL)
DIN-Rail and wall mount design
Installation in a pollution degree 2 industrial environment
Standalone installation
2
Package Contents
1 - CBG5-0602-SFP-Lite(-T) - Unit weight: 0.726kg ( 1.60lb), Shipping weight: 1.024kg ( 2.26lb)
2 - Wall mounting brackets and screws
1 - Quick installation guide
1 - Mini-USB B type male to DB9 RS-232 female cable
Safety Precaution
Attention
If the DC voltage is supplied by an external circuit, please use a protection device on the power supply
input. Supply by UL Listed industrial use power. The industrial Ethernet switch’s hardware specs, ports,
cabling information, and wiring installation will be described within this user manual.
Attention
Si la tension CC est fournie par un circuit externe, veuillez utiliser un dispositif de protection sur l'entrée
d'alimentation. Fourniture par courant industriel homologué UL. Les spécifications matérielles, les ports,
les informations de câblage et l'installation du câblage du convertisseur de média industriel seront décrits
dans ce manuel d'utilisation.
Warning Labels
The caution label means that you should check the certain information on user manual when working with
the device. (Shown in Figure 1.1)
Étiquettes d'avertissement
L'étiquette d'avertissement signifie que vous devez vérifier certaines informations sur le manuel
d'utilisation lorsque vous travaillez avec l'appareil. (Montré dans la Figure 1.2)
Figure 1.1 - Caution Label
Figure 1.1 - Étiquette de mise en garde
Figure 1.2 - Hot Surface Warning Label
Figure 1.2 - Étiquette d'avertissement de surface chaude
3
HARDWARE DESCRIPTION
Physical Dimensions
Figure 2.1, below, shows the physical dimensions of CBG5-0602-SFP-Lite series.
(W x H x D) is 51mm x 102mm x 90mm
Figure 2.1: Physical Dimensions
4
Front Panel
The front panel of the CBG5-0602-SFP-Lite series industrial PoE+ gigabit Managed Ethernet Switch is
shown below in Figure 2.2.
Figure 2.2: The Front Panel
Top View
Figure 2.3, below, shows the top panel of the CBG5-0602-SFP-Lite series switches that is equipped with
one 4-pin removal terminal block connector for dual DC power inputs (48-55VDC).
Figure 2.3: Top Panel View
5
LED Indicators
There are LED light indicators located on the front panel of the industrial switch that display the power
status and network status. Each LED indicator has a different color and has its own specific meaning, see
below in Table 2.1.
Table 2.1: LED Indicators
LED
Color
Description
P1
Green
On
Off
P2
Green
On
Off
STATUS
Red
On
Green
On
Blinking
Red
On
Blinking
MASTER
Green
On
Off
RING
Green
On
Blinking
Off
PoE Load
Off
6
Green
On
Green + Blue
On
Green+Blue+Red
On
Green+Blue+Red
(red flash)
On
SFP
Link/Act/Speed
(Port1-2)
Green
On
Blinking
Off
Amber
On
Blinking
Off
Copper Port
Link/ACT/Speed
(Port3- 6)
Green
On
Flashing
Off
Amber
On
Flashing
Off
PoE Mode
(Port3-6)
Green
On
Off
Blinking
(1 time/s)
Amber
On
Off
7
PoE Port LED Indicators
The LED light indicators on the PoE copper port can help the user know if an event once occurs or is
happening. When the event is happening, user can verify the event from the Dual-color LED status. If the
port has recovered from an event, user can verify the event from the blinking frequency of the PoE LED(5
seconds as a cycle,).
PoE Budget Overload Event
When the total PoE budget is overload (>100%), the PoE port of the lowest priority PoE port will be
shutdown. The PoE LED of the port will act cyclically as below until the port is recovered from the event:
After the PoE port is recovered from the PoE budget overload event, the PoE LED of the will act cyclically
as below until the event indicator is clear manually:
**AF/AT: Amber; BT: Green
PoE Port Over Current Event (Per Port)
When the current limit of the specific PoE port is exceeded, the PoE power will be shutdown.
The PoE LED of the port will act cyclically as below until the port is recovered from the event:
**AF/AT: Amber; BT: Green
After the PoE port is recovered from the PoE Port Over Current event, the PoE LED of the port will act
cyclically as below until the event indicator is clear manually:
Blinking
(1 time/s)
Green/Amber
Alternating
Amber(0.5s
ec)&
Green(0.5se
c) blinking
8
**AF/AT: Amber; BT: Green
Cable Short Event
When the working PD encounters a cable short event, the PoE Port LED will act cyclically as below until
the port is recovered from the event:
After the PoE port is recovered from the Cable Short event, the PoE LED of the port will act cyclically as
below until the event indicator is clear manually:
**AF/AT: Amber; BT: Green
Dual PD Fail Event
When one channel of the connected dual PD is failed, the PoE port will be shutdown. The PoE Port LED of
the port will act cyclically as below until the port is recovered from the event:
After the PoE port is recovered from the Dual PD Fail event, the PoE LED of the shutdown port will act
cyclically as below until the event indicator is clear manually:
**AF/AT: Amber; BT: Green
[Notice]
1. The system will automatically retry to recover from the event failure every 20 seconds.
2. To clear the warning PoE Indicator of the recovered port, please re-plug the port cable or re-open the
PoE function of the port via DIP Switch(>=2sec).
9
Relay Contact Alarm Warning
2-pin 1*24VDC@1A resistive normal open on 6-pin terminal block.
The relay contact alarm will be triggered when anyone of the pre-configured events occurs. User can
configure the event warning for the events listed below. (Software Default: OFF)
The relay contact alarm will be triggered when anyone of the listed events occurs.
Key trigger event 1: Power-1 or Power-2 is inactive
Key trigger event 2: PoE total loading >100% PoE output budget
Key trigger event 3: PoE over current per port
Key trigger event 4: Cable short per port
Key trigger event 5: One of the channels in Dual PD fail
[Notice] When the relay is triggered because of Event 2~5, the relay contact alarm, will update the status
every 30 seconds. If there is no event happening for 30 seconds, the relay contact alarm will be turn off. If
the user disables the failed PoE port by removing the cable or Dip Switch manually, the relay will be
recovered immediately.
10
Ethernet Ports
RJ-45 Ports (Auto MDI/MDIX)
The RJ-45 ports are auto-sensing for 10Base-T, 100Base-TX or 1000Base-T
devices connections. Auto MDI/MDIX means that the switch can connect to
another switch or workstation without changing the straight-through or
crossover cabling. See the figures as below for straight-through and
crossover cabling schematics.
10/100BASE-T(X) RJ-45 Pin Assignments (Table 2.2)
Crossover Cable
Straight Through Cable
Pin Number / Signal
Pin Number / Signal
Pin Number / Signal
Pin Number / Signal
1 / RX+
3 / TX+
1 / RX+
1 / TX+
2 / RX-
6 / TX-
2 / RX-
2 / TX-
3 / TX+
1 / RX+
3 / TX+
3 / RX+
6 / TX-
2 / RX-
6 / TX-
6 / RX-
Table 2.2
1000BASE-T RJ-45 Pin Assignments (Table 2.3)
Crossover Cable
Straight Through Cable
Pin Number / Signal
Pin Number / Signal
Pin Number / Signal
Pin Number / Signal
1 / TP0+
3 / TP1+
1 / TP0+
1 / TP1+
2 / TP0-
6 / TP1-
2 / TP0-
2 / TP1-
3 / TP1+
1 / TP0+
3 / TP1+
3 / TP0+
4 / TP2+
7 / TP3+
4 / TP2+
4 / TP3+
5 / TP2-
8 / TP3-
5 / TP2-
5 / TP3-
6 / TP1-
2 / TP0-
6 / TP1-
6 / TP0-
7 / TP3+
4 / TP2+
7 / TP3+
7 / TP2+
8 / TP3-
5 / TP2-
8 / TP3-
8 / TP2-
Table 2.3
Note: “+” and “-” signs represent the polarity of the wires that make up each wire pair.
11
Cabling
Use the four twisted-pair, category 5e, or the above cabling for RJ-45 port connections. The cable between
the Switch and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long.
The small form-factor pluggable (SFP) is a compact optical transceiver used in optical communications for
both telecommunication and data communication applications.
Caution: Please employ optional optical transceiver (SFP/Fixed Fiber) that complies with IEC
60825-1 and classified as Class 1 laser product.
Attention: Veuillez utiliser un émetteur-récepteur optique (SFP) conforme à la norme CEI 60825-1
et classé comme produit laser de classe 1.
To connect the transceiver and LC cable, please follow below steps:
Step 1. Insert the SFP transceiver module into the SFP slot as shown below in Figure 2.4. Notice that the
triangle mark is at the bottom of the SFP slot. Figure 2.5 shows SFP transceiver module was
inserted.
Figure 2.4: Transceiver to the SFP Module
Figure 2.5: Transceiver Inserted
12
Step 2. Insert the fiber cable of the LC connector into the transceiver as shown below in Figure 2.6.
Figure 2.6: LC Connector to the Transceiver
To remove the LC connector from the transceiver, please follow the steps shown below:
Step 1. Press the upper side of the LC connector from the transceiver and pull it out to release as shown
below in Figure 2.7
Figure 2.7: Remove LC Connector
Step 2. Push down the metal clasp and pull the transceiver out by the plastic part as shown below in
Figure 2.8
Figure 2.8: Pull Out from the SFP Module
13
Wiring the Power Inputs
Caution: Please follow the below steps to insert the power wire.
Attention: Veuillez suivre les étapes ci-dessous pour insérer leble d'alimentation.
Step 1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-) contacts on
the terminal block connector as shown below in Figure 2.9.
Figure 2.9: Power Terminal Block
Step 2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in Figure 2.10.
Figure 2.10: Power Terminal Block
Caution: Only use copper conductors, 125°C, tighten to 7 in-lbs (0.79 Nm). The
wire gauge for the terminal block should range between 18~20 AWG.
Attention: Utilisez uniquement des conducteurs en cuivre, 125 ° C, serrer à 7 in-
lbs (0,79 Nm). Le calibre des fils du bornier doit être compris entre 18 et 20
AWG.
14
Wiring the Fault Alarm Contact
The fault alarm contact is in the middle of the terminal block connector as the picture shows below in
Figure 2.11. By inserting the wires, it will detect the fault status including power failure or port link failure
(managed industrial switch only) and form a normally open circuit. An application example for the fault
alarm contact is shown below in Figure 2.11.
Figure 2.11: Wiring the Fault Alarm Contact
Caution: The wire gauge for the terminal block should range between 12 ~ 24 AWG.
If only using one power source, jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power
fault alarm.
Attention: Le calibre des fils du bornier doit être compris entre 12 et 24 AWG.
Si vous n'utilisez qu'une seule source d'alimentation, jumelez les broches 1 à 5 et les broches
2 à 6 pour éliminer l'alarme de panne de courant.
Grounding Note
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run
the ground connection from the ground screw to the grounding surface prior to connecting devices. The
grounding screw symbol is shown blow in Figure 2.12.
Figure 2.12: Grounding screw symbol
Caution: Using a shielded cable achieves better electromagnetic compatibility.
Attention: L'utilisation d'un câble blindé permet une meilleure compatibilité électromagnétique.
15
MOUNTING INSTALLATION
DIN-Rail Mounting
The DIN-Rail is pre-installed on the industrial Ethernet Switch from the factory. If the DIN-Rail is not on the
industrial Ethernet Switch, please see Figure 3.1 to learn how to install the DIN-Rail on the Switch.
Figure 3.1: The Rear Side of the Switch and DIN-Rail Bracket
Follow the steps below to learn how to hang the industrial Switch.
Step 1. Use the screws to install the DIN-Rail bracket on the rear side of the industrial Switch.
Step 2. To remove the DIN-Rail bracket, do the opposite from Step 1.
Step 3. After the DIN-Rail bracket is installed on the rear side of the Switch, insert the top of the DIN-Rail
on to the track as shown below in Figure 3.2.
Figure 3.2: Insert the Switch on the DIN-Rail
16
Step 4. Lightly pull down the bracket on to the rail as shown below in Figure 3.3.
Figure 3.3: Stable the Switch on DIN-Rail
Step 5. Check if the bracket is mounted tightly on the rail.
Step 6. To remove the industrial Switch from the rail, do the opposite from the above steps.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Leonton CBG5-0602-SFP-Lite Manuel utilisateur

Catégorie
Commutateurs réseau
Taper
Manuel utilisateur

dans d''autres langues