SAFETY NOTICE: If this heater is not properly installed, a
house re may result. For your safety, follow the installation
instructions. Never use make shift compromises during
the installation of this heater. Contact local building or
re ofcials about permits, restrictions and installation
requirements in your area.
CAUTION! Please read this entire manual before you install
or use your new room heater. Failure to follow instructions
may result in property damage, bodily injury, or even
death. Improper Installation Could Void Your Warranty!
U.S. Environmental Protection Agency
Certied to comply with 2020
particulate emissions standards.
Tested to ALT-125, ASTM E2515,
ASTM E3053 and CSA B415.1-10
Certied to: UL 1482-11 (R2015) and
Certied to: ULC-S627-00
Room Heater, Solid Fuel Type, Also
For Use In Mobile Homes (USA Only)
SAVE THESE INSTRUCTIONS THIS MANUAL WILL HELP YOU TO
OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER,
AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY.
KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
This manual is subject to change without notice.
ALL PICTURES SHOWN ARE FOR ILLUSTRATIVE PURPOSES
ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT
ENHANCEMENT.
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon monoxide, which
is known to the State of California to cause cancer, birth defects and/or other
reproductive harm. For more information, go to www.P65warnings.ca.gov
Ce produit peut vous exposer à des agents chimiques, y compris au monoxyde de
carbone, lesquels sont reconnus dans l’État de la Californie comme causant le cancer et
des malformations congénitales ou autres dommages au fœtus. Pour obtenir plus de
renseignements, veuillez consulter le site www.P65warnings.ca.gov
Report #: F20-596
R
-2-
CAUTIONS:
Hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns.
Do not use chemicals or uids to ignite the re.
Do not leave the stove unattended when the door is slightly opened.
Do not burn garbage, ammable uid such as gasoline, naphtha or motor oil.
Do not connect to any air distribution duct or system.
Always close the door after the ignition.
Combustible: Wood
Colors: Metallic Black
Flue Pipe Diameter: 6” (153 mm)
Flue Pipe Type: (Standard Single Wall or Double
Wall):
Black or Blued Steel 2100°F (650°C)
Minimum Chimney Height: 12’ (3.7 m)
Maximum Log Length: 21” (534 mm)
Dimensions
Overall: Depth x Width x Height: 21.5” x 32” x 33.5” (547 mm x 813 mm x 864 mm)
Combustion Chamber: Width x Depth: 11-3/8” x 24-3/4” (289 mm x 629 mm)
Volume: Cubic Feet: 2.32 ft³
Door Opening: Width x Height: 10” x 11-3/8” (854 mm x 289 mm)
Note: Register your product on line at www.usstove.com. Save your receipt with your records for any claims.
The instructions pertaining to the installation of your wood stove comply with UL-1482 (R2015) and ULC-S627-00
(R2016) standards. This manual describes the installation and operation of the USSC, US2941EB wood heater. This
heater meets the 2020 U.S. Environmental Protection Agency’s cordwood emission limits for wood heaters sold
after May 15, 2020. Under specic test conditions, this heater has been shown to deliver heat at rates ranging from
17,611 to 48,127 Btu/hr (0.91g/hr and efciency of 72%). Note: The BTU ratings mentioned above are based on the
EPA test protocol under specic test conditions. Our advertised BTU’s are based on the rst hour of operation at
high burn rate burning cordwood.
-3-
UNPACK AND INSPECT
Remove the packing from the appliance and inspect
for any damage. Ensure that the bricks are positioned
correctly and not broken (see illustration for proper
brick arrangement). Make sure that the bafe board,
above the air tubes, is in place and undamaged.
BLOWER ASSEMBLY
The blower assembly must be disconnected from the
source of electrical supply before attempting the
installation.
1. Remove the Panel (A) using tin snips or knock out
using a hammer and chisel careful not to distort
the mounting surface.
2. Attach the Blower Mounting Box (B) to the rear of
the unit using four(4) of the supplied #10 screws.
3. Then mount the Blower Assembly (C) with the four
(4) remaining screws.
CABINET DOOR KNOB ASSEMBLY
The cabinet door knob is mounted on the inside of
the cabinet door for shipping purposes and must be
removed and re-installed for proper usage. To get the
cabinet door open, place your hand under the cabinet
frame (right-hand side of the cabinet door) and pull
out on the door.
Follow these instructions for door knob assembly:
1. Remove the machine screw and the door knob.
2. Place the knob on the outside of the cabinet
door, re-install the machine screw and tighten. Be
careful not to strip out the threads in the handle.
HANDLE & FEED DOOR OPERATION
1. Lift the handle up to disengage the latch.
2. Crack open the feed door for approximately 10
seconds to allow excess heat to escape.
3. After approximately 10 seconds lower the handle
and continue to pull the door open.
HOW TO OPEN THE TOP LID
CAUTION! DO NOT OPEN OR CLOSE THE TOP WHEN THE
HEATER IS HOT! To open, grasp the top at the front or on
each corner and lift all the way up until the support rod
stops the motion. Then gently lower the top allowing
the support rod to settles in the cup, holding the top
open. To close, lift the top until the support rod is out of
the cup. Pull the rod forward and lower the lid closed.
Assembly Instructions
NOTE: During opening and closing of the feed and
ash doors of this heater, it may seem that the t of the
door is "too tight". As the heater is red, the gasketing
"settles" or "seats" itself in the door. The tight t at the
factory and before the heater's initial ring is to ensure
a good seal after the gasketing "settles".
B
A
C
MACHINE
SCREW
CABINET
DOOR KNOB
-4-
SMOKE CURTAIN INSTALLATION
1. Open the cabinet door and the re door.
2. Locate the two hooks inside the rebox above the
re door opening as shown.
3. Slide the smoke curtain through the re door and
hook into place. Note: the smoke curtain has a
bend at the bottom. When placing the smoke
curtain into place ensure the bend it facing
toward the re door as shown.
SAFETY NOTICE
If this stove is not properly installed, a house re may result. To reduce the risk of re, follow the installation
instructions.
Consult your municipal building department or re ofcials about permits, restrictions and installations
requirements in your area.
Use smoke detectors in the room where your stove is installed.
Keep furniture and drapes well away from the stove.
Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter uid, or similar liquids to start or
“freshen up” a re in this heater. Keep all such liquids well away from the heater while it is in use.
In the event of a chimney re, push the air control full closed to deprive the re of oxygen. Call the re
department.
Do not connect to any air distribution duct or system.
A source of fresh air into the room or space heated shall be provided when required.
POSITIONING THE STOVE
It is very important to position the wood stove as close as possible to the chimney, and in an area that will favour
the most efcient heat distribution possible throughout the house. The stove must therefore be installed in the
room where the most time is spent, and in the most spacious room possible. Wood stoves produce radiating
heat, that is the heat we feel when we are close to a wood stove. A wood stove also functions by convection.
Convection is the displacement of hot air accelerated upwards and its replacement with cooler air. If necessary,
the hot air distribution from the stove may be facilitated by the installation of a blower. The wood stove must not
be hooked up to a hot air distribution system since an excessive accumulation of heat may occur. A wood stove
must never be installed in a hallway or near a staircase, since it may block the way in case of re or fail to respect
required clearances.
Installation
Inside view of the re
door opening without
the smoke curtain
installed.
Inside view of the re
door opening with the
smoke curtain installed.
Cabinet Door
Fire Door
-5-
CLEARANCES TO COMBUSTIBLES
It is of utmost importance that the clearances to combustible materials be strictly adhered to during installation
of the stove.
A
B
SIDEWALL
F
E
C
D
BACK WALL
G
J
H
Key in mm
A Sidewall To Flue 23 585
B Sidewall To Stove 14 356
C Ceiling Height 84 2134
D Top Of Stove To Ceiling 50.5 1283
E Back Wall To Flue 18 458
F Back Wall To Stove 28 712
G Wall To Corner (Angled Installation) 18 458
H Wall To Corner Fuel Loading Side (Angled Installation) 18 458
J Wall To Flue (Angled Installation) 18 458
L
K
MN
P P
Floor Protector
BACK WALL
SIDEWALL
Key in mm
K Front 8 204
L Rear 8 204
M Fuel Loading Side
16 (USA)
18 (CAN)
407 (USA)
458 (CAN)
N Left Side 8 204
P Flue Pipe 2 51
Note: When choosing a location for this unit, make sure
there is enough space available to fully open the door.
Floor to ceiling height must be at least 7’ (2.13 m) in all cases.
Do not place any combustible material within 4’ (1.2 m) of the front of the unit.
The clearance between the ue pipe and a wall are valid only for vertical walls and for vertical ue pipe.
The chimney connector must not pass through an attic or roof space, closet or similar concealed space, a
oor, or a ceiling.
For Canadian installations, where passage through a wall, or partition of combustible construction is desired,
the installation must conform to CAN/CSA-B365.
A ue pipe crossing a combustible wall must have a minimum clearance of 18” (458 mm).
To reduce ue clearances from combustible materials, contact your local safety department.
The provision that clearances may only be reduced by means approved by regulatory authority
FLOOR PROTECTOR
This heater must have a non-combustible oor protector with a minimum type 1 ember protection extending
beneath the heater if the oor is constructed of combustible material. If a oor pad is used, it should be UL
listed or equal. The oor protector should be large enough to extend under the stove and beyond each side
as indicated. If there is a horizontal run of ue pipe, there needs to be oor protection under it that extends two
inches beyond either side of the pipe.
-6-
SPECIAL MOBILE HOME REQUIREMENTS (APPROVED FOR USE IN MOBILE HOMES (USA ONLY)
WARNING - DO NOT INSTALL IN A SLEEPING ROOM.
CAUTION - THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED.
In addition to the previously detailed installation requirements, mobile home installations must meet the following
requirements:
The space heater is to be connected to a factory-built chimney conforming to UL 103, therefore it must be a
Type HT (2100°F).
The heater must be permanently attached to the oor.
The heater must be electrically grounded to the steel chassis of the mobile home with 8 ga copper wire using
a serrated or star washer to penetrate paint or protective coating to ensure grounding.
When moving your mobile home, all exterior venting must be removed while the mobile home is being
relocated. After relocation, all venting must be reinstalled and securely fastened.
Outside air is mandatory for mobile home installation. See your dealer for purchasing.
Check with your local building ofcials as other codes may apply.
Only use the specied components listed in this manual for this unit. The use of components that are not meant
for this unit can cause unsafe conditions.
COMBUSTION AIR ASSEMBLY INSTRUCTIONS (REQUIRED FOR MOBILE HOME INSTALLATIONS)
This appliance requires a source of combustion air when installed in a mobile home.
If the building this unit is being installed in is of tight construction or has negative pressure problems, an outside
source of air is needed. Below is a list of possible indicators that a source of outside combustion air may be
required.
The stove does not draw steadily, smoke rollout occurs, wood burns poorly, or back-drafts occur whether or
not there is combustion present.
Existing fuel-red equipment in the house, such as replaces or other heating appliances, smell, do not operate
properly, suffer smoke roll-out when opened, or back-drafts occur whether or not there is combustion present.
Opening a window slightly on a calm (windless) day alleviates any of the above symptoms.
The house is equipped with a well-sealed vapor barrier and tight tting windows and/or has any powered
devices that exhaust house air.
There is excessive condensation on windows in the winter.
A ventilation system is installed in the house.
If an outside air intake is required, you may purchase a standard 4” fresh air kit from you local stove dealer.
4FAK INSTALLATION
Installation of a fresh air kit is required when installing
this stove inside a mobile home. Installation must
adhere to all local codes. If after reading these
instructions you have any doubt about your ability to
complete the installation properly, you must obtain
the services of a licensed heating and cooling
contractor or certied stove installer.
4” Fresh Air Kit
1. With the stove in the operating position, mark and drill a 5” hole through the wall at the desired point of entry.
The point of entry should be at or below the level of the intake air tube on the stove.
-7-
3. Slide both hose clamps over the aluminium ex pipe. Then slide the ex pipe over the air intake tube of the
stove. Next tighten the hose clamp over the end of the aluminium ex hose.
4. Route the ex pipe to the through wall connection and slide the ex pipe over the tail piece. Apply the
second hose clamp over the tail piece and tighten.
SECURING APPLIANCE TO THE FLOOR
Use the designated holes to secure the unit to the oor as shown.
2. Slide the tail portion of the weather hood through the hole. Secure the weather hood with the provided
screws at each of the four corners. Caulk around the edges of the hood and screws to seal. This task should
be done after the stove has been installed and the exhaust piping routed. Try to position the hole for the air
intake as near as possible to the stove.
-8-
CHIMNEY CONNECTOR (STOVE PIPE)
Your chimney connector and chimney must have the same
diameter as the stove outlet (6”). If this is not the case, we
recommend you contact your dealer in order to ensure there
will be no problem with the draft. The stove pipe must be made
of aluminized or cold roll steel with a minimum thickness of 0.021”
or 0.53 mm. It is strictly forbidden to use galvanized steel. Your
smoke pipe should be assembled in such a way that the male
section (crimped end) of the pipe faces down. Attach each
of the sections to one another with three equidistant metal
screws. The pipe must be short and straight. All sections installed
horizontally must slope at least 1/4 inch per foot, with the upper
end of the section toward the chimney. Any installation with a
horizontal run of chimney pipe must conform to NFPA 211. You
may contact NFPA (National Fire Protection Association) and request the latest edition of the NFPA Standard
211. To ensure a good draft, the total length of the coupling pipe should never exceed 8’ to 10’ (2.4m to 3.04 m).
Except for cases of vertical installation, cathedral-roof style where the smoke exhaust system can be much longer
and connected without problem to the chimney at the ceiling of the room. There should never be more than
two 90° elbows in the smoke exhaust system. Installation of a “barometric draft stabilizer” (replace register) on
a smoke exhaust system is prohibited. Furthermore, installation of a draft damper is not recommended. Indeed,
with a controlled combustion wood stove, the draft is regulated upon intake of the combustion air in the stove
and not at the exhaust.
IMPORTANCE OF PROPER DRAFT
Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your
chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. Too
much draft may cause excessive temperatures in the appliance. Inadequate draft may cause backpufng into
the room and ‘plugging’ of the chimney. Inadequate draft will cause the appliance to leak smoke into the room
through appliance and chimney connector joints. An uncontrollable burn or excessive temperature indicates
excessive draft.
To
Appliance
CHIMNEY
Take into account the chimney’s location to ensure
it is not too close to neighbors or in a valley which
may cause unhealthy or nuisance conditions. Your
wood stove may be hooked up with a 6” factory
built or masonry chimney. If you are using a factory
built chimney, it must comply with UL 103 or CSA-B365
standard; therefore it must be a Type HT (2100°F). It
is extremely important that it be installed according
to the manufacturer’s specications. If you are using
a masonry chimney, it is important that it be built in
compliance with the specications of the National
Building Code. It must be lined with re clay bricks,
metal or clay tiles sealed together with re cement. Note: Round ues are the most efcient. The interior diameter
of the chimney ue must be identical to the stove smoke exhaust. A ue which is too small may cause draft
problems, while a large ue favours rapid cooling of the gas, and hence the build-up of creosote and the
risk of chimney res. Note that it is the chimney and not the stove which creates the draft effect; your stove’s
performance is directly dependent on an adequate draft from your chimney. The following recommendations
may be useful for the installation of your chimney:
1. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
2. It must rise above the roof at least 3’ (0.9m) from the uppermost point of contact.
3. The chimney must exceed any part of the building or other obstruction within a 10’ (3.04m) distance by a
height of 2’ (0.6m).
4. Installation of an interior chimney is always preferable to an exterior chimney. Indeed, the interior chimney
will, by denition, be hotter than an exterior chimney, being heated up by the ambient air in the house.
Therefore the gas which circulates will cool more slowly, thus reducing the build-up of creosote and the risk
of chimney res.
5. The draft caused by the tendency for hot air to rise will be increased with an interior chimney.
6. Using a re screen at the extremity of the chimney requires regular inspection in order to ensure that it is not
obstructed thus blocking the draft, and it should be cleaned when used regularly.
-9-
FACTORY BUILT CHIMNEY
When a metal prefabricated chimney is used, the
manufacturer’s installation instructions must be followed.
You must also purchase (from the same manufacturer)
and install the ceiling support package or wall pass-
through and “T” section package, restops (where
needed), insulation shield, roof ashing, chimney cap,
etc. Maintain proper clearance to the structure as
recommended by the manufacturer. The chimney
must be the required height above the roof or other
obstructions for safety and proper draft operation.
MASONRY CHIMNEY
Ensure that a masonry chimney meets the minimum
standards of the National Fire Protection Association
(NFPA) by having it inspected by a professional. Make
sure there are no cracks, loose mortar or other signs
of deterioration and blockage. Have the chimney
cleaned before the stove is installed and operated.
When connecting the stove through a combustible wall
to a masonry chimney, special methods are needed.
-10-
COMBUSTIBLE WALL CHIMNEY CONNECTOR PASS-THROUGHS
Method A. 12” (304.8 mm) Clearance to Combustible Wall
Member: Using a minimum thickness 3.5” (89 mm) brick and a
5/8” (15.9 mm) minimum wall thickness clay liner, construct a
wall pass-through. The clay liner must conform to ASTM C315
(Standard Specication for Clay Fire Linings) or its equivalent.
Keep a minimum of 12” (304.8 mm) of brick masonry between
the clay liner and wall combustibles. The clay liner shall run
from the brick masonry outer surface to the inner surface of the
chimney ue liner but not past the inner surface. Firmly grout or
cement the clay liner in place to the chimney ue liner.
Method B. 9” (228.6 mm) Clearance to Combustible Wall
Member: Using a 6” (152.4 mm) inside diameter, listed, factory-
built Solid-Pak chimney section with insulation of 1” (25.4 mm) or
more, build a wall pass-through with a minimum 9” (228.6 mm)
air space between the outer wall of the chimney length and
wall combustibles. Use sheet metal supports fastened securely
to wall surfaces on all sides, to maintain the 9” (228.6 mm) air
space. When fastening supports to chimney length, do not
penetrate the chimney liner (the inside wall of the Solid-Pak
chimney). The inner end of the Solid-Pak chimney section shall
be ush with the inside of the masonry chimney ue, and sealed
with a non-water soluble refractory cement. Use this cement to
also seal to the brick masonry penetration.
Method C. 6” (152.4 mm) Clearance to Combustible Wall
Member: Starting with a minimum 24 gage (.024” [.61 mm])
6” (152.4 mm) metal chimney connector, and a minimum 24
gage ventilated wall thimble which has two air channels of 1”
(25.4 mm) each, construct a wall pass-through. There shall be a
minimum 6” (152.4) mm separation area containing berglass
insulation, from the outer surface of the wall thimble to wall
combustibles. Support the wall thimble, and cover its opening
with a 24-gage minimum sheet metal support. Maintain the 6”
(152.4 mm) space. There should also be a support sized to t
and hold the metal chimney connector. See that the supports
are fastened securely to wall surfaces on all sides. Make sure
fasteners used to secure the metal chimney connector do not
penetrate chimney ue liner.
Method D. 2” (50.8 mm) Clearance to Combustible Wall Member:
Start with a solid-pak listed factory built chimney section at least
12” (304 mm) long, with insulation of 1” (25.4 mm) or more, and
an inside diameter of 8” (2 inches [51 mm] larger than the 6”
[152.4 mm] chimney connector). Use this as a pass-through for a
minimum 24-gauge single wall steel chimney connector. Keep
solid-pak section concentric with and spaced 1” (25.4 mm) off
the chimney connector by way of sheet metal support plates at
both ends of chimney section. Cover opening with and support
chimney section on both sides with 24 gage minimum sheet
metal supports. See that the supports are fastened securely to
wall surfaces on all sides. Make sure fasteners used to secure
chimney ue line.
NOTES:
1. Connectors to a masonry chimney, excepting method B, shall extend in one continuous section through the
wall pass-through system and the chimney wall, to but not past the inner ue liner face.
2. A chimney connector shall not pass through an attic or roof space, closet or similar concealed space, or a
oor or ceiling.
-11-
TYPE
WEIGHT
(LBS. CU. FT., DRY)
PER CORD
EFFICIENCY
RANKING
SPLITS
MILLIONS BTU’s/
CORD
Hickory 63 4500 1.0 Well 31.5
White Oak 48 4100 .9 Fair 28.6
Red Oak 46 3900 .8 Fair 27.4
Beech 45 3800 .7 Hard 26.8
Sugar Maple 44 3700 .6 Fair 26.2
Black Oak 43 3700 .6 Fair 25.6
Ash 42 3600 .5 Well 25.0
Yellow Birch 40 3400 .4 Hard 23.8
Red Maple 38 3200 .3 Fair 22.6
Paper Birch 37 3100 .3 Easy 22.1
Elm/Sycamore 34 2900 .2 Very Difcult 20.1
Red Spruce 29 1800 .1 Easy 16.1
WOODSTOVE UTILIZATION
Your heating appliance was designed to burn wood only; no other materials should be burned. Waste and
other ammable materials should not be burned in your stove. Any type of wood may be used in your stove, but
specic varieties have better energy yields than others. Please consult the following table in order to make the
best possible choice.
Fuel Recommendations
It is EXTREMELY IMPORTANT that you use DRY WOOD only in your wood stove. The wood should have dried for
9 to 15 months, such that the humidity content (in weight) is reduced below 20% of the weight of the log. It is
very important to keep in mind that even if the wood has been cut for one, two, or even more years, it is not
necessarily dry, if it has been stored in poor conditions. Under extreme conditions it may rot instead of drying.
This point cannot be over stressed; the vast majority of the problems related to the operation of a wood stove is
caused by the fact that the wood used was too damp or had dried in poor conditions. These problems can be:
- ignition problems
- creosote build-up causing chimney res
- low energy yield
- blackened windows
- incomplete log combustion
Smaller pieces of wood will dry faster. All logs exceeding 6” in diameter should be split. The wood should not be
stored directly on the ground. Air should circulate through the cord. A 24” to 48” air space should be left between
each row of logs, which should be placed in the sunniest location possible. The upper layer of wood should be
protected from the element but not the sides.
TESTING YOUR WOOD
When the stove is thoroughly warmed, place one piece of split wood (about ve inches in diameter) parallel
to the door on the bed of red embers.
Keep the air control full open and close the door. If ignition of the piece is accomplished within 90 seconds
from the time it was placed in the stove, your wood is correctly dried. If ignition takes longer, your wood is
damp.
If your wood hisses and water or vapor escapes at the ends of the piece, your wood is soaked or freshly cut
(green). Do not use this wood in your stove. Large amounts of creosote could be deposited in your chimney,
creating potential conditions for a chimney re.
-12-
Operating Instructions
CAUTIONS: HOUSE FIRE HAZARDS
Do not store wood on oor protector, underneath stovepipe(s) if applicable, or anywhere within clearances
to combustible surfaces specied for this appliance.
Never operate with secondary tubes, ber board, or insulation removed.
OPERATING SAFETY PRECAUTIONS
Never overre this appliance by building excessively hot res as a house/building re may result. You are
overring the appliance if it begins to glow or turn red.
Never build excessively large res in this type of appliance as damage to the rebox or smoke leakage may
result.
Hot while in operation. Keep children, clothing, and furniture away. Contact may cause skins burns. Do not
touch the appliance until it has cooled.
Provide adequate air for combustion to the room where the appliance is installed.
Inspect chimney liner every 60 days. Replace liner immediately if it is rusting or leaking smoke into the room.
Attempts to achieve heat output rates that exceed heater design specications can result in permanent
damage to the heater.
WARNING: EXPLOSION HAZARD
Never use chemicals, gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter uid, or similar
ammable liquids to start or “freshen up” a re in the appliance.
Keep all ammable liquids, especially gasoline, out of the vicinity of the appliance - whether in use or in
storage.
This heater is designed to burn natural wood only. Higher efciencies and lower emissions generally result when
burning air dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods. DO NOT
BURN:
1. Garbage;
2. Lawn clippings or yard waste;
3. Materials containing rubber, including tires;
4. Materials containing plastic;
5. Waste petroleum products, paints or paint thinners,
or asphalt products;
6. Materials containing asbestos;
7. Construction or demolition debris;
8. Railroad ties or pressure-treated wood;
9. Manure or animal remains;
10. Salt water driftwood or other previously salt water
saturated materials;
11. Unseasoned wood; or
12. Paper products, cardboard, plywood, or
particleboard. The prohibition against burning
these materials does not prohibit the use of re
starters made from paper, cardboard, saw dust,
wax and similar substances for the purpose of
starting a re in an affected wood heater.
Burning these materials may result in release of toxic fumes or render the heater ineffective and cause smoke.
Dead wood lying on the forest oor should be considered wet, and requires full seasoning time. Standing dead
wood can usually be considered to be about 2/3 seasoned. Splitting and stacking wood before it is stored
accelerates drying time. Storing wood on an elevated surface from the ground and under a cover or covered
area from rain or snow also accelerates drying time. A good indicator if wood is ready to burn is to check the
piece ends. If there are cracks radiating in all directions from the center then the wood should be dry enough
to burn. If your wood sizzles in the re, even though the surface is dry, it may not be fully cured, and should be
seasoned longer.
Do not burn manufactured logs made of wax impregnated sawdust or logs with any
chemical additives. Manufactured logs made of 100% compressed sawdust can be
burned, but be careful burning too much of these logs at the same time. Start with one
manufactured log and see how the stove reacts. You can increase the number of logs
burned at a time to making sure the temperature never rises higher than 475°F (246°C)
on a magnetic thermometer for installation on single wall stove pipes or 900°F (482°C)
on a probe thermometer for installation on double wall stove pipe. The thermometer
should be placed about 18” (457 mm) above the stove. Higher temperatures can
lead to overheat and damage your stove.
-13-
TAMPER WARNING
This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating
instructions in this manual.
EFFICIENCIES
Efciencies can be based on either the lower heating value (LHV) or the higher heating value (HHV) of the fuel.
The lower heating value is when water leaves the combustion process as a vapor, in the case of woodstoves the
moisture in the wood being burned leaves the stove as a vapor. The higher heating value is when water leaves
the combustion process completely condensed. In the case of woodstoves this would assume the exhaust gases
are room temperature when leaving the system, and therefore calculations using this heating value consider
the heat going up the chimney as lost energy. Therefore, efciency calculated using the lower heating value of
wood will be higher than efciency calculated using the higher heating value. The best way to achieve optimum
efciencies is to learn the burn characteristic of you appliance and burn well-seasoned wood. Higher burn rates
are not always the best heating burn rates; after a good re is established a lower burn rate may be a better
option for efcient heating. A lower burn rate slows the ow of usable heat out of the home through the chimney,
and it also consumes less wood.
Notice: Use solid wood fuel only! Do not burn garbage , or ammable uids. Do not use coal. This appliance is not
designed to accommodate the air ow (draft) required to properly burn coal or coal products. Do not elevate
the re using grates or irons. Build the re directly on the rebrick.
FUELING INSTRUCTIONS
This wood stove has been certied by the US EPA to meet strict 2020 guidelines. To ensure this unit produces
the optimal minimum emissions it is critical that only well-seasoned cordwood is burned (see the “Fuel
Recommendations” section of this manual). Burning unseasoned wet wood only hurts your stoves efciency and
leads to accelerated creosote buildup in your chimney. Be considerate of the environment and only burn dry
wood.
For a cold start-up, place 3 to 4 pieces of newspaper into the rebox. On top of the
newspaper, lay 4 lbs of kindling in random placement to ensure airow through the
kindling. On top of the kindling, place approximately 6 lbs of small pieces of cordwood.
NOTE: Use smaller pieces of wood during start-up and a high burn rate to increase the
stove’s temperature.
CAUTION: DO NOT LEAVE APPLIANCE UNATTENDED WITH THE DOOR OPEN.
4 lb
Turn the air control knob to the high position. Light the newspaper, close the door, and allow the kindling to ignite.
Once the kindling has burned down to a starter coal bed, load the unit with approximately 24 lbs of fuel for the
rst high burn load. Close the door immediately.
After the rst high burn load and the stove is well warmed up, adjust the unit as needed for a medium or low burn
setting.
For a medium burn, once the high burn fuel load is burned down to an established coal bed, load the unit with
27-28 lbs of cordwood and keep the door slightly open for 5 minutes. Leave the air control fully open (in the “HI”
position) for 15 minutes. After 15 minutes turn the air control knob to the medium position. The blower can be
turned on after 30 minutes.
24 lbs
-14-
For a low burn setting once the high burn (or medium) fuel load is burned down to an established coal bed, load
the unit with 27-28 lbs of cordwood and keep the door slightly open for 5 minutes. Leave the air control fully open
(in the “HI” position) for 15 minutes. After 15 minutes begin to turn the air control knob to the “Low” position. NOTE:
Do not close the air too quickly. Closing the air too quickly will cause the unit to smoke.
WARNINGS:
NEVER OVERFIRE YOUR STOVE. IF ANY PART OF THE STOVE STARTS TO GLOW RED, OVER FIRING IS HAPPENING.
READJUST THE AIR INTAKE CONTROL AT A LOWER SETTING.
THE INSTALLATION OF A LOG CRADLE or GRATES IS NOT RECOMMENDED IN YOUR WOOD STOVE. BUILD FIRE
DIRECTLY ON FIREBRICK.
NEVER PUT WOOD ABOVE THE FIREBRICK LINING OF THE FIREBOX.
Attempts to achieve heat output rates that exceed heater design specications can result in permanent
damage to the heater.
ADDING FUEL
1. Once you have obtained a good bed of embers, you should reload the unit. To do so, turn the air control
knob to high a few seconds before opening the stove’s door.
2. Open the door very slowly; open it one or two inches for 5 to 10 seconds, before opening it completely to
increase the draft and thus eliminate the smoke which is stagnant in a state of slow combustion in the stove.
3. Rake the glowing embers to the front of the door opening. Add fuel being careful not to overload or
overre the appliance. When adding fuel be careful not to smother the re. Make sure the embers do not
obstruct the air inlet. NOTE: For optimal operation of this unit, it is recommend to operate it with a wood load
approximately equivalent to the height of re bricks. It is important to note that wood combustion consumes
ambient oxygen in the room. In the case of negative pressure, it is a good idea to allow fresh air in the room,
either by opening a window slightly or by installing a fresh air intake system on an outside wall.
4. Close the feed door and secure tightly.
5. Adjust the air inlet control as described in the “Fueling Instruction” section of this manual.
6. Empty ashes regularly. Do not allow ashes to pile up. Properly dispose of hot ashes (see the “Ash Removal
And Disposal” section of this manual).
7. Burn small, intense res instead of large, slow burning res when possible. Large slow burning res can deposit
creosote within the heating system.
8. Learn your appliance’s operating characteristics to obtain optimum performance.
VISIBLE SMOKE
The amount of visible smoke being produced can be an effective method of determining how efciently the
combustion process is taking place in the given settings. Visible smoke consists of unburned fuel and moisture
leaving your stove. Learn to adjust the air settings of your specic unit to produce the smallest amount of visible
smoke. Wood that has not been seasoned properly and has a high wood moisture content will produce excess
visible smoke and burn poorly.
AIR TUBES
The air tubes assembled in this unit are designed to provide an accurate mix of secondary air to ensure the
highest efciency. Any damage or deterioration of these tubes may reduce the efciency of combustion. The air
tubes are held in position by screws or snap pins. Locate these to either side of the tube and remove it to allow
the tube to be removed and replaced.
27-28 lbs
-15-
BLOWER OPERATION
The variable speed blower circulates air warmed by the rebox into the living area to distribute the heat more
evenly. The blower control knob is located on the side of the blower housing. Turn the knob clockwise to turn
the blower on. The speed is controlled by turning the knob clockwise for slower speeds and counter-clockwise
for faster speeds. To turn the blower off, turn the speed control knob fully counter-clockwise. It is recommended
to turn the blower off when the unit is not in operation. The blower needs to be removed and air-blown clean.
Make sure the blades do not have build up. Caution! Route the Power Supply Cord away from the heat source
and out of high trafc areas.
CLEAN OUT MAINTENANCE
Burning unseasoned wet wood only hurts your stoves efciency and leads to
accelerated creosote buildup in your chimney. The clean outs are secured to
the rebox with two 5/16” screws. Remove the clean outs and vacuum out any
accumulated ash. This should be done at least once per month or more frequently
if large amounts of ash are noticed while cleaning or if the stove does not seem
to be burning properly. The ring and ash doors must be closed and sealed during
operation.
CAUTION: Do not overre appliance. You are overring if any part of the appliance glows red. Close the door and
shut the damper immediately to reduce the air supply and slow down the re.
Chimney Maintenance
CAUTION: Slow burning res for extended use or burning green wood may cause excessive creosote build-up.
Ignition of creosote or overring could cause a chimney re. Chimney res burn extremely hot and may ignite
surrounding combustible materials. In case of a chimney re, call the re department immediately!
CREOSOTE FORMATION AND NEED FOR REMOVAL
When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to
form creosote. The creosote vapors condense in the relatively cool chimney ue of a slow-burning re. As a result,
creosote residue accumulates on the ue lining. When ignited this creosote makes an extremely high temper re.
The chimney connector and chimney should be inspected at least once every two months during the heating
season to determine if a creosote build-up has occurred. If creosote has accumulated (3 mm or more), it should
be removed to reduce the risk of a chimney re.
We strongly recommend that you install a magnetic thermometer on your smoke exhaust pipe, approximately
18” above the stove. This thermometer will indicate the temperature of your gas exhaust fumes within the smoke
exhaust system. The ideal temperature for these gases is somewhere between 275°F and 500°F. Below these
temperatures, the build-up of creosote is promoted. Above 500°F, heat is wasted since a too large quantity is lost
into the atmosphere.
TO PREVENT CREOSOTE BUILD UP
Always burn dry wood. This allows clean burns and higher chimney temperatures, therefore less creosote
deposit.
Leave the air control fully open for about 5 minutes every time you reload the stove to bring it back to proper
operating temperatures. The secondary combustion can only take place if the rebox is hot enough.
Always check for creosote deposit once every two months and have your chimney cleaned at least once a
year.
If a chimney or creosote re occurs, close all dampers immediately. Wait for the re to go out and the heater
to cool, then inspect the chimney for damage. If no damage results, perform a chimney cleaning to ensure
no more creosote deposits are remaining in the chimney.
CAUTION: A chimney re may cause ignition of wall studs or rafters which were assumed to be a safe distance
away from the chimney. If a chimney re occurs, have your chimney inspected by a qualied expert before using
again.
ASH REMOVAL & DISPOSAL
Whenever ashes get 3 to 4 inches deep in your rebox or ash pan, remove excess ashes. Leave an ash bed
approximately 1 inch deep on the rebox bottom to help maintain a hot charcoal bed. Ashes should be placed
in a metal container with a tight-tting lid. The closed container of ashes should be placed on a non-combustible
oor or the ground, away from all combustible materials, pending nal disposal. The ashes should be retained in
the closed container until all cinders have thoroughly cooled.
Air Cleanout
-16-
ATTENTION: This wood heater needs periodic inspection and repair for proper operation. It is against federal
regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual.
WARNING: NEVER OPERATE THE STOVE WITHOUT A GASKET OR WITH A BROKEN ONE. DAMAGE TO THE STOVE OR
EVEN HOUSE FIRE MAY RESULT.
CAUTIONS:
ASHES COULD CONTAIN HOT EMBERS EVEN AFTER TWO DAYS WITHOUT OPERATING THE STOVE.
THE ASH PAN CAN BECOME VERY HOT. WEAR GLOVES TO PREVENT INJURY.
NEVER BURN THE STOVE WITH THE ASH TRAP OPEN. THIS WOULD RESULT IN OVER FIRING THE STOVE. DAMAGE
TO THE STOVE AND EVEN HOUSE FIRE MAY RESULT.
SMOKE & CO MONITORS
Burning wood naturally produces smoke and carbon monoxide (CO) emissions. CO is a poisonous gas when
exposed to elevated concentrations for extended periods. While the modern combustion systems in heaters
drastically reduce the amount of CO emitted out the chimney, exposure to the gases in closed or conned areas
can be dangerous. Make sure your stove gaskets and chimney joints are in good working order and sealing
properly to ensure unintended exposure. It is recommended that you use both smoke and CO monitors in areas
having the potential to generate CO.
GASKET CARE
This unit’s door uses a 1” diameter rope gasket. It is recommended that you change the door gasket (which makes
your stove door air tight) once a year, in order to ensure good control over the combustion, maximum efciency
and security. To change the door gasket, simply remove the damaged one. Carefully clean the available gasket
groove, apply a high temperature silicone sold for this purpose, and install the new gasket. You may light up your
stove again approximately 24 hours after having completed this operation.
WHITE /
BLANC
GREEN /
VERT
WHITE /
BLANC
BLACK /
NOIR
BLACK /
NOIR
BLACK /
NOIR
BLOWER
RHEOSTAT /
RHÉOSTAT DU
VENTILATEUR
BLOWER MOTOR
BLOWER SPECS: 120VAC, 60 Hz AC,0.55amp /
MTEUR DU
VENTILATEUR
DÉTAILS TECHNIQUES: 120VAC, 60 Hz CA,0,55AMP
BLACK /
NOIR
BLACK /
NOIR
Blower Wiring Diagram
NOTICE: DO NOT ALLOW THE POWER
CORD TO TOUCH HOT SURFACES! KEEP
THE POWER CORD AT LEAST 12”/30.5 CM
FROM THE STOVE OR PIPE SURFACES.
DANGER: SHOCK HAZARD DISCONNECT
POWER SOURCE BEFORE INSTALLATION AND
WHENEVER SERVICING BLOWER ASSEMBLY.
CAUTION: MOVING PARTS CAN CAUSE
INJURY. DO NOT OPERATE WITH COVER
REMOVED.
NOTICE: ANY REPLACEMENT WIRING
MUST HAVE EQUIVALENT INSULATION
AND TEMPERATURE RATING (105° C).
-17-
Repair Parts
1
2
3
4
6
7
9
10
11
12
13
14
15
16
17
19
20
21
22
23
18
24
25
26
27
28
5
8
IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS
PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER. USE OF THIRD PARTY
COMPONENTS WILL VOID THE WARRANTY.
Key Part # Description Qty
1 67966 Cabinet Top Assy 1
2 22761 Flue Collar Ring 1
3 610143 Casing Back 1
4 40246 6” C.I. Flue Collar 1
5 88032 Flue Collar Gasket 1
6 891492 Blower Assembly (B36) 1
7 25598 Blower Mounting Box 1
8 29329 Smoke Curtain 1
9 610508 Right Side Casing 1
10 67969 Cabinet Door Assy. 1
11 67444 Ash Pan Weldment 1
12 67859 Base Weldment 1
13 22110 Heat Shield 1
14 25550 H. Pin Draft Damper 1
15 27469 Damper Arm 1
16 610987 Air Distribution Box Assembly 1
17 89687 Black Thermostat Knob 1
18 610985 Cabinet Front Weldment/Assy. 1
19 611015 Draft Door Weldment 1
20 40075 Draft Door Frame 1
21 29422 Restrictor 1
22 88090 Gasket 1
23 27461 Main Air Channel 1
24 27491 Air Channel Stop 1
25 611018 Secondary Panel Weldment 1
26 67967 Cabinet Left End Assy. 1
27 27467 Bottom Back Spacer 1
28 27466 Top Back Spacer 1
-18-
Repair Parts
IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS
PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER. USE OF THIRD PARTY
COMPONENTS WILL VOID THE WARRANTY.
Key Part # Description Qty
1 27486 Door Handle 2
2 27462 Door Catch 2
3 40763 Feed Door 1
4 88032 1” Rope Fiber 3.75 ft
5 27489 Fire Door Hinge 1
6 27460 Ash Door Hinge 1
7 88032 1” Rope Fiber 2.5 ft
8 40764 Cast Door 1
3
5
8
1
2
7
6
4
2
1
3
5
4
6
7
8
9
10
11
14
13
15
16
18
17
12
Key Part # Description Qty
1 88336 Insulation Blanket 1
2 88335 Bafe Board 2
3 29437 Tube Retainer 1
4 29438 Bafe Side 1
5 27291 Front Liner Top 1
6 29408 Right Retainer 1
7 893285 Firebrick 3
8 27484 Top Brick Rack 2
9 89066A Pumice Firebrick (4-1/2 X 9) 17
10 610223 Cleanout Cover Weldment 1
11 610227 Primary Air Outlet (Welded) 1
12 610221 Floor (Welded) 1
13 27564 Floor Back 1
14 27472 Brick Spacers 2
15 892945 Pumice Firebrick(4-1/2 X 7-1/2) 1
16 893289 Secondary Tube (13.125”) 5
17 29407 Left Retainer 1
18 27478 Rear Brick Spacer 1
-19-
It is recommended that your heating system is serviced regularly and that the appropriate Service Interval
Record is completed.
SERVICE PROVIDER
Before completing the appropriate Service Record below, please ensure you have carried out the service
as described in the manufacturer’s instructions. Always use the manufacturer's specied spare part when
replacement is necessary.
Service Record
Service 01 Date: _____________________
Engineer Name: ________________________________
License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________
Stove Inspected: Chimney Swept:
Items Replaced: ________________________________
Service 03 Date: _____________________
Engineer Name: ________________________________
License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________
Stove Inspected: Chimney Swept:
Items Replaced: ________________________________
Service 05 Date: _____________________
Engineer Name: ________________________________
License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________
Stove Inspected: Chimney Swept:
Items Replaced: ________________________________
Service 07 Date: _____________________
Engineer Name: ________________________________
License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________
Stove Inspected: Chimney Swept:
Items Replaced: ________________________________
Service 02 Date: _____________________
Engineer Name: ________________________________
License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________
Stove Inspected: Chimney Swept:
Items Replaced: ________________________________
Service 04 Date: _____________________
Engineer Name: ________________________________
License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________
Stove Inspected: Chimney Swept:
Items Replaced: ________________________________
Service 06 Date: _____________________
Engineer Name: ________________________________
License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________
Stove Inspected: Chimney Swept:
Items Replaced: ________________________________
Service 08 Date: _____________________
Engineer Name: ________________________________
License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________
Stove Inspected: Chimney Swept:
Items Replaced: ________________________________
This manual will help you obtain efcient, dependable service from your heater, and enable you to order repair
parts correctly.
Keep this manual in a safe place for future reference.
When writing, always give the full model number which is on the nameplate attached to the heater.
When ordering repair parts, always give the following information as shown in this list:
1. The part number ______________________________________________________________________________
2. The part description ___________________________________________________________________________
3. The model number ____________________________________________________________________________
4. The serial number _____________________________________________________________________________
Ce manuel vous aidera à obtenir un service able et efcace de votre appareil de chauffage, et vous
permettre de commander correctement les pièces de rechange.
Conservez ce manuel dans un endroit sûr pour référence future.
Lors de l’écriture, toujours donner le numéro de modèle complet qui se trouve sur la plaque signalétique xée
sur l’appareil de chauffage.
Lors de la commande des pièces de rechange, fournir les informations suivantes comme indiqué dans cette
liste:
1. Le numéro de pièce __________________________________________________________________________
2. La description de la pièce _____________________________________________________________________
3. Le numéro de modèle ________________________________________________________________________
4. Le numéro de série ___________________________________________________________________________
How To Order Repair Parts
Comment Commander Des Pièces De Rechange
United States Stove Company
227
Industrial Park Rd.,
South Pittsburg, TN 37380
PH: (800) 750-2723
www.usstove.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

US Stove Company US2941EB Le manuel du propriétaire

Catégorie
Poêles
Taper
Le manuel du propriétaire

dans d''autres langues