GE CGU486P2TS1 Guide d'installation

Taper
Guide d'installation
Professional Rangetop
CGU366, CGU486
31-2000816 Rev. 0 11-20 GEA
Questions? Visit cafeappliances.com.
Installation Instructions
TM
Contents
Safety Information .......................................................2
Design Information
Product Dimensions and Clearances ............................4
Installation Information
High Altitude Kit .............................................................7
Materials Provided .........................................................7
Materials Required (not provided) .................................7
Tools Required ..............................................................7
Installation
Remove Packaging .......................................................8
Cut the Countertop Opening .........................................9
Install Rangetop ..........................................................10
Conversion to Propane (LP) Gas or Natural Gas .......10
Gas Supply ..................................................................11
Electrical Connections .................................................12
Check Burners .............................................................12
Check Surface Burners ...............................................12
Finalize Installation ......................................................13
When All Hookups Are Completed..............................13
UX12BS36PSS, UX12BS48PSS Accessory Installation
Optional Accessories—12” High Backsplash
Tools and Materials Required .....................................14
Install 12” Backsplash .................................................14
UXADBS36PSS, UXADBS48PSS Accessory Installation
Accessories—30” To 36” Adjustable Backsplash)
Tools and Materials Required .....................................15
Install the Wall Support Panels ...................................15
Install Cover Panels ....................................................16
English • Français • Español
2 31-2000816 Rev. 0
Safety Information
READ AND SAVE THESE INSTRUCTIONS
IN THE COMMONWEALTH OF MASSACHUSETTS
Ŷ This product must be installed by a licensed plumber
or gas fitter.
Ŷ :KHQXVLQJEDOOW\SHJDVVKXWRIIYDOYHVWKH\VKDOO
EHWKH7KDQGOHW\SH
Ŷ $IOH[LEOHJDVFRQQHFWRUZKHQXVHGPXVWQRWH[FHHG
5 feet.
WARNING
FIRE OR EXPLOSION HAZARD
,IWKHLQIRUPDWLRQLQWKLVPDQXDOLVQRWIROORZHGH[DFWO\
DILUHRUH[SORVLRQPD\UHVXOWFDXVLQJSURSHUW\GDPDJH
personal injury or death.
Installation must be performed by a qualified installer.
Read these instructions completely and carefully.
,QVWDOODWLRQRIWKLVUDQJHPXVWFRQIRUPZLWKORFDOFRGHV
RULQWKHDEVHQFHRIORFDOFRGHVZLWKWKH1DWLRQDO
)XHO*DV&RGH$16,=1)3$ODWHVWHGLWLRQ
,Q&DQDGDLQVWDOODWLRQPXVWFRQIRUPZLWKWKHFXUUHQW
1DWXUDO*DV,QVWDOODWLRQ&RGH&$1&*$%RU
WKHFXUUHQW3URSDQH/3,QVWDOODWLRQ&RGH&$1&*$
%DQGZLWKORFDOFRGHVZKHUHDSSOLFDEOH7KLV
UDQJHKDVEHHQGHVLJQFHUWLILHGE\&6$,QWHUQDWLRQDO
DFFRUGLQJWR$16,=ODWHVWHGLWLRQDQG&DQDGLDQ
*DV$VVRFLDWLRQDFFRUGLQJWR&$1&*$ODWHVWHGLWLRQ
When installing a gas appliance the use of
ROGIOH[LEOHFRQQHFWRUVFDQFDXVHJDVOHDNVDQG
SHUVRQDOLQMXU\$OZD\VXVHD1(:IOH[LEOHFRQQHFWRU
Leak testing of the appliance shall be conducted
according to the manufacturer instructions.
The range must be electrically grounded in accordance
ZLWKORFDOFRGHVRULQWKHDEVHQFHRIORFDOFRGHVLQ
DFFRUGDQFHZLWKWKH1DWLRQDO(OHFWULFDO&RGH$16,
1)3$ODWHVWHGLWLRQ,Q&DQDGDHOHFWULFDOJURXQGLQJ
PXVWEHLQDFFRUGDQFHZLWKWKHFXUUHQW&6$&
&DQDGLDQ(OHFWULFDO&RGH3DUWDQGRUORFDOFRGHV6HH
Electrical Connections in this section.
'RQRWLQVWDOOWKLVSURGXFWZLWKDQDLUFXUWDLQKRRGRU
RWKHUUDQJHKRRGWKDWRSHUDWHVE\EORZLQJDLUGRZQRQ
WKHFRRNWRS7KLVDLUIORZPD\LQWHUIHUHZLWKRSHUDWLRQRI
WKHJDVEXUQHUVUHVXOWLQJLQILUHRUH[SORVLRQKD]DUG
Have a question or need assistance with your appliance? Try the Café website 24 hours a day, any day of the
year! You can also shop for more great Café products and take advantage of all our on-line support services
designed for your convenience. In the US: cafeappliances.com. (In Canada, cafeappliances.ca.)
31-2000816 Rev. 0 3
Safety Information
READ AND SAVE THESE INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Ŷ IMPORTANT Save these instructions
for local inspector’s use.
Ŷ IMPORTANT Observe all governing
codes and ordinances.
Ŷ IMPORTANT Remove all packing
material and literature from oven before connecting
gas and electrical supply to range.
Ŷ IMPORTANT To avoid damage to
\RXUFDELQHWVFKHFNZLWK\RXUEXLOGHURUFDELQHW
VXSSOLHUWRPDNHVXUHWKDWWKHPDWHULDOVXVHGZLOO
QRWGLVFRORUGHODPLQDWHRUVXVWDLQRWKHUGDPDJH
7KLVRYHQKDVEHHQGHVLJQHGLQDFFRUGDQFHZLWK
the requirements of UL and CSA International and
FRPSOLHVZLWKWKHPD[LPXPDOORZDEOHZRRGFDELQHW
temperatures of 194°F (90°C).
Ŷ Note to Installer — Be sure to leave these
LQVWUXFWLRQVZLWKWKHFRQVXPHU
Ŷ Note to Consumer —.HHSWKHVHLQVWUXFWLRQVZLWK
\RXU2ZQHU¶V0DQXDOIRUIXWXUHUHIHUHQFH
Ŷ Servicer — The electrical diagram is in an envelope
attached to the back of the range.
Ŷ Proper installation is the responsibility of the
installer.
Ŷ Product failure due to improper installation is not
FRYHUHGXQGHUZDUUDQW\
Ŷ )RU&DIp3DUWVDQG$FFHVVRULHVYLVLWRXUZHEVLWHDW
cafeappliances.com.
,Q&DQDGD cafeappliances.ca.)
Ŷ,I\RXUHFHLYHGDGDPDJHGUDQJHWRSV\RXVKRXOG
contact your dealer.
IF SOLD OUTSIDE THE U.S. AND
CANADA
WARNING
,I\RXZLVKWRXVHWKLVSURGXFWZLWK
Liquefied Petroleum (LP) gas containing greater
WKDQEXWDQH\RXPXVWSXUFKDVHWKHEXWDQH
FRQYHUVLRQNLW&;%8357RRUGHUSOHDVHFDOO
1.888.664.8403 or 1.787.276.4051. Failure to do so
PD\UHVXOWLQFDUERQPRQR[LGHRUILUHKD]DUG
VENT HOOD COMBINATIONS
A suitable overhead vent hood is required for models
ZLWKDJULOODQGLVUHFRPPHQGHGIRUDOORWKHUPRGHOV
'XHWRWKHKLJKKHDWFDSDFLW\RIWKLVXQLWSDUWLFXODU
DWWHQWLRQVKRXOGEHSDLGWRWKHKRRGDQGGXFWZRUN
installation to assure it meets local building codes.
&OHDUDQFHVWRKRUL]RQWDOVXUIDFHVDERYHWKHUDQJH
PHDVXUHGWRWKHFRRNLQJVXUIDFHDUHEHORZ)DLOXUHWR
comply may result in fire hazard.
Ŷ,QVWDOODWLRQVZLWKRXWDKRRGUHTXLUH´PLQLPXPWR
combustibles.
Ŷ$FXVWRPKRRGLQVWDOODWLRQZLWKH[SRVHGKRUL]RQWDO
FRPEXVWLEOHVVXUIDFHVPXVWKDYHDQ$XWR2QIHDWXUH
Ŷ)RURWKHULQVWDOODWLRQVZLWKDKRRGUHIHUWRKRRG
installation instructions for specific hood clearances.
CAUTION
7KHVHUDQJHWRSVDUHH[WUHPHO\
KHDY\6RPHGLVDVVHPEO\ZLOOUHGXFHWKHZHLJKW
FRQVLGHUDEO\'XHWRWKHZHLJKWDQGVL]HRIWKH
rangetop and to reduce the risk of personal injury or
damage to the product:
TWO PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION OF RANGETOPS.
THREE PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION OF 48” RANGETOPS.
Rating Label Location Rating Label Location
4 31-2000816 Rev. 0
Design Information
PRODUCT DIMENSIONS AND CLEARANCES FOR 48” MODELS
ADDITIONAL CLEARANCES:
$OORZ´PLQLPXPFOHDUDQFHWR
DQDGMDFHQWZDOORQHDFKVLGH
Working areas adjacent to
the rangetop should have 18”
PLQLPXPFOHDUDQFHEHWZHHQ
countertop and the bottom of the
ZDOOFDELQHW
)RULVODQGLQVWDOODWLRQPDLQWDLQ
LQPLQLPXPIURPFXWRXWWR
back edge of countertop and 3 in.
minimum from cutout to side edges
RIFRXQWHUWRSVHHWRSYLHZ
WARNING
Installations
ZLWKRXWDKRRGUHTXLUH´PLQLPXP
to combustibles. A custom hood
LQVWDOODWLRQZLWKH[SRVHGKRUL]RQWDO
combustible surfaces must have
DQ$XWR2QIHDWXUH5HIHUWRKRRG
installation instructions for specific
hood clearances.
The surface of the entire back
ZDOODERYHWKHUDQJHDQGEHORZ
WKHKRRGPXVWEHFRYHUHGZLWKD
QRQFRPEXVWLEOHPDWHULDOVXFKDV
PHWDOFHUDPLFWLOHEULFNPDUEOH
or other stone.
CAUTION
To prevent
drafts from affecting burner
RSHUDWLRQVHDODOORSHQLQJVLQ
floor under appliance and behind
DSSOLDQFHZDOO
** As defined in the National Fuel Gas
&RGH$16,=&6$%
&XUUHQW(GLWLRQ&OHDUDQFHVIURPQRQ
combustible materials are not part of the
$16,=&6$VFRSHDQGDUHQRW
certified by CSA. Clearances less than
12” must be approved by local codes
DQGRUWKHDXWKRULW\KDYLQJMXULVGLFWLRQ
Universal Utility Locations
2”
17”
16”
Locate gas
inlet on back
ZDOORURQ
floor 2” from
EDFNZDOO
´0LQ
´
8”
´
12” Minimum
Each Side
´
7KHRSHQLQJEHWZHHQ
a 4” high backsplash
PXVWEH´WRDOORZ
the rangetop to slide
EDFNDJDLQVWWKHZDOO
´0D[
18” Min.
48” Minimum
to Combustibles
48” Minimum
12” Minimum to
Adjacent Wall
48” *
1RQFRPEXVWLEOHPDWHULDO
48”
12” Minimum to
Combustibles or 0”
WRQRQFRPEXVWLEOH
material above the
cooking surface **
0”
Clearance
Back
3” Min. 3” Min.
´0LQ
Island Cutout
7RS9LHZ
48” Min. to
Combustibles
´+HLJKW
´:LGWK
´WR
Front of
Bullnose
31-2000816 Rev. 0 5
Design Information
PRODUCT DIMENSIONS AND CLEARANCES FOR 36” MODELS
ADDITIONAL CLEARANCES:
$OORZ´PLQLPXPFOHDUDQFHWR
DQDGMDFHQWZDOORQHDFKVLGH
Working areas adjacent to
the rangetop should have 18”
PLQLPXPFOHDUDQFHEHWZHHQ
countertop and the bottom of the
ZDOOFDELQHW
)RULVODQGLQVWDOODWLRQPDLQWDLQ
LQPLQLPXPIURPFXWRXWWR
back edge of countertop and 3 in.
minimum from cutout to side edges
RIFRXQWHUWRSVHHWRSYLHZ
WARNING
Installations
ZLWKRXWDKRRGUHTXLUH´PLQLPXP
to combustibles. A custom hood
LQVWDOODWLRQZLWKH[SRVHGKRUL]RQWDO
combustible surfaces must have
DQ$XWR2QIHDWXUH5HIHUWRKRRG
installation instructions for specific
hood clearances.
The surface of the entire back
ZDOODERYHWKHUDQJHDQGEHORZ
WKHKRRGPXVWEHFRYHUHGZLWKD
QRQFRPEXVWLEOHPDWHULDOVXFKDV
PHWDOFHUDPLFWLOHEULFNPDUEOH
or other stone.
CAUTION
To prevent
drafts from affecting burner
RSHUDWLRQVHDODOORSHQLQJVLQ
floor under appliance and behind
DSSOLDQFHZDOO
** As defined in the National Fuel Gas
&RGH$16,=&6$%
&XUUHQW(GLWLRQ&OHDUDQFHVIURPQRQ
combustible materials are not part of the
$16,=&6$VFRSHDQGDUHQRW
certified by CSA. Clearances less than
12” must be approved by local codes
DQGRUWKHDXWKRULW\KDYLQJMXULVGLFWLRQ
Universal Utility Locations
2”
17”
16”
Locate gas
inlet on back
ZDOORURQ
floor 2” from
EDFNZDOO
´0LQ
´
8”
´
12” Minimum
Each Side
35”
7KHRSHQLQJEHWZHHQ
a 4” high backsplash
PXVWEH´WRDOORZ
the rangetop to slide
EDFNDJDLQVWWKHZDOO
´0D[
18” Min.
48” Minimum
to Combustibles
12” Minimum to
Adjacent Wall
36” *
1RQFRPEXVWLEOHPDWHULDO
36”
48” Min. to
Combustibles
0”
Clearance
Back
3” Min. 3” Min.
Island Cutout
7RS9LHZ
´0LQ
12” Minimum to
Combustibles or 0”
WRQRQFRPEXVWLEOH
material above the
cooking surface **
´
Height
´:LGWK
´WR
Front of
Bullnose
36” Minimum
6 31-2000816 Rev. 0
Design Information
PRODUCT DIMENSIONS AND CLEARANCES
48” and 36” Rangetop Models
&RQWUROSDQHOSURMHFWVIRUZDUGVIURP
standard depth cabinets.
)URQWRIGHHSFDELQHWVFDQDOLJQZLWK
control panel beveled edge.
,QFOXGHWKHRYHUKDQJRIWKHUHDUWULPZKHQFRXQWHUWRSFRQWLQXHVEHKLQGWKHSURGXFW
7KHRYHUKDQJLVGHFRUDWLYHRQO\7KHZHLJKWRIWKHUDQJHWRSLVIXOO\VXSSRUWHGE\WKHVLGHWULPV
0D[LPXPFRXQWHUWRSFXWRXWGHSWKIURPWKHEDFNRIWKHUHDUWULPWRWKHEDFNHGJHRIFKDPIHUDW
WKHVLGHVRIWKHFRQWUROSDQHOW\SLFDOO\WKHPD[LPXPFRXQWHUWRSFXWRXWGHSWKIURQWWREDFN
0LQLPXPFRXQWHUWRSFXWRXWGHSWKLV´
Rangetop
´$ERYH$GMDFHQW
Countertops
´$ERYH$GMDFHQW
Countertops
Rangetop
´
To front of control knobs
´
To front of bullnose
8”
Countertop
Level
´
´
´
´
´
1”
´
´
To pipe
stub center
´
Countertop
level
´
To front of
control panel
´
Height
Rear finished edge of the
control panel
31-2000816 Rev. 0 7
Installation Information
TOOLS REQUIRED
MATERIALS REQUIRED (not provided)
Adjustable Wrench
´'ULYHURU:UHQFK
Safety Glasses
Drill and
Appropriate Bits
Measuring Tape
3KLOOLSV6FUHZGULYHU
6DEHU6DZ
Carpenter’s Square
Level
Hand Truck
6KXW2II9DOYHPipe Fittings
IRRWPD[LPXPOHQJWK´2'&6$
DSSURYHGIOH[LEOHPHWDOJDVVXSSO\
NOTE:3XUFKDVHQHZIOH[LEOHOLQHGRQRW
XVHSUHYLRXVO\XVHGIOH[LEOHJDVOLQH
Pipe Thread
Sealant
MATERIALS PROVIDED
Regulator
+ROG'RZQ6WUDS
INSTALLATION AT HIGH ALTITUDE
2YHUIWSURGXFWFRQILJXUHGIRUQDWXUDOJDVRU
propane requires installation of kit (WB28X39728
for natural gas and WB28X39729 for propane gas).
)ROORZWKHLQVWUXFWLRQVLQFOXGHGZLWKWKHNLW
8 31-2000816 Rev. 0
Installation
1
REMOVE PACKAGING
CAUTION
Stand clear. The ends of the cut metal
EDQGLQJPD\VQDSWRZDUG\RX
Ŷ&XWWKHPHWDOEDQGLQJ
Ŷ5HPRYHSDFNDJLQJWDSHDQGIRDP'LVSRVHRI
packaging materials properly.
Ŷ5HPRYHJULOOJULGGOHFRYHUVJULOOJUDWHDQGEXUQHU
grates.
Ŷ/LIWRXWFDVWLURQJULGGOHIOXHFRYHUJUHDVHWURXJKV
and pads.
Ŷ&XWWKHWLHVKROGLQJWKHJULOOJUDWHWRWKHJULOOIUDPH
Ŷ/LIWRIIEXUQHUFDSVDQGUHPRYHIRDPSDGWKHQOLIWRII
burner heads and remove foam pad.
Remove Foam Pads
Griddle Flue Cover
Grease Troughs
Ties
31-2000816 Rev. 0 9
Installation
2
CUT THE COUNTERTOP OPENING
0HDVXUHFDUHIXOO\ZKHQFXWWLQJWKHFRXQWHUWRS0DNH
sure sides of the opening are parallel.
Ŷ$OORZ´IUHHVSDFHEHORZWKHWRSVXUIDFHRIWKH
countertop.
Ŷ$OORZDGGLWLRQDOFOHDUDQFHVEHORZWKHEXUQHUER[
to install the regulator and make house supply
FRQQHFWLRQV8VHDHOERZWRURXWHWKHJDV
FRQQHFWLRQVDQGOLPLWLQWHUIHUHQFHZLWKGUDZHUVRU
other cabinetry features.
Ŷ7KHVHUDQJHWRSVDUHGHVLJQHGWRKDQJIURPWKH
countertop by their side flanges.
Ŷ6PRRWKDQ\URXJKHGJHVRQWKHFRXQWHUWRSEHIRUH
installing the rangetop.
Formica countertop edges must be finished.
The countertop must be strong enough to support the
ZHLJKWRIWKHUDQJHWRS
Cutout Opening with False Bottom
Ŷ<RXFDQFRQVWUXFWWKHFXWRXWZLWKDIDOVHERWWRPWR
conceal the bottom of the rangetop.
±%XLOGWKHIDOVHERWWRPXVLQJDVROLGPDWHULDOFXWD
´[´KROHLQWKHOHIWUHDUFRUQHUIRUWKH
JDVLQOHWDQGSRZHUFRUGFOHDUDQFHV
´ZLGHPRGHOVDUHGHVLJQHGWRILWLQ´RUZLGHUEDVHFDELQHWV ´ZLGHPRGHOVDUHGHVLJQHGWRILWLQ´RUZLGHUEDVHFDELQHWV
Dimensions
A (Dia.) B C D
36” Rangetop ´ ´ ´ ´
48” Rangetop ´ ´
´
´
10 31-2000816 Rev. 0
4
CONVERSION TO PROPANE (LP)
OR NATURAL GAS
The pressure regulator and the burner orifices are
set for natural gas at the factory. To operate the
UDQJHWRSZLWKSURSDQH/3WKHUHJXODWRUDQGEXUQHU
orifices must be converted. The conversion must be
performed by a qualified propane (LP) gas installer.
Keep these instructions and all orifices in case you
ZDQWWRFRQYHUWEDFNWRQDWXUDOJDV
Installation
3
INSTALL RANGETOP
Ŷ6OLGHWKHUDQJHWRSLQWRWKHRSHQLQJ0DNHVXUHWKH
rangetop is evenly seated and supported.
Ŷ$KROGGRZQVWUDSZLWKVFUHZVLVSURYLGHGWRVHFXUH
WKHUDQJHWRSWRWKHUHDURUVLGHFDELQHWZDOOV
Ŷ5HPRYHWKHKROGGRZQVWUDSIURPWKHEDFNRIWKH
rangetop. Attach one end of the strap to the back of
the rangetop.
Ŷ6HFXUHWKHRWKHUHQGRIWKHVWUDSDVKLJKDV
SRVVLEOHWRWKHFDELQHWEDFNZDOORUDGMDFHQW
cabinet. Keep the strap as short as possible for
better security.
Back Wall
+ROG'RZQ
Strap
Location and
Attachment
Tape
Propane
Conversion
Kit
Gas Inlet
31-2000816 Rev. 0 11
Installation
5
GAS SUPPLY
WARNING
Fire Hazard: Do not use a flame to
check for gas leaks.
WARNING
([SORVLRQ+D]DUG'RQRWH[FHHG
IWOEVRIWRUTXHZKHQPDNLQJJDVOLQHFRQQHFWLRQV
Overtightening may damage the pressure regulator
UHVXOWLQJLQILUHRUH[SORVLRQKD]DUG
Gas Pressure Regulator
<RXPXVWXVHWKHJDVSUHVVXUHUHJXODWRUVXSSOLHG
ZLWKWKLVUDQJHWRS)RUSURSHURSHUDWLRQVWKHLQOHW
SUHVVXUHWRWKHUHJXODWRUVKRXOGEHDVIROORZV
Natural Gas:
Minimum pressure: 6” of Water Column
0D[LPXPSUHVVXUH´RI:DWHU&ROXPQ
Propane (LP) Gas:
Minimum pressure: 11” of Water Column
0D[LPXPSUHVVXUH´RI:DWHU&ROXPQ
If you are not sure about the inlet pressure contact
local gas supplier.
Shut off the main gas supply valve before
disconnecting the old rangetop and leave it off
until the new hook-up has been completed. Don’t
forget to relight the pilot on other gas appliances
when you turn the gas back on.
Because hard piping restricts movement of the
UDQJHWRSWKHXVHRID&6$,QWHUQDWLRQDOFHUWLILHG
IOH[LEOHPHWDODSSOLDQFHFRQQHFWRULVUHFRPPHQGHG
XQOHVVORFDOFRGHVUHTXLUHDKDUGSLSHGFRQQHFWLRQ
,IWKHKDUGSLSLQJPHWKRGLVXVHGFDUHIXOO\DOLJQ
WKHSLSHWKHUDQJHWRSFDQQRWEHPRYHGDIWHUWKH
connection is made.
7RSUHYHQWJDVOHDNVSXWSLSHWKUHDGVHDODQWRQRU
ZUDSSLSHWKUHDGWDSHZLWK7HIORQDURXQGDOOPDOH
H[WHUQDOSLSHWKUHDGV
A. Install provided pressure regulator directly to the
JDVLQOHWSLSHRIWKHUDQJHWRS5HIHUWRWKHDUURZ
RQWKHEDFNRIWKHUHJXODWRUIRUJDVIORZGLUHFWLRQ
(QVXUHWKHIURQWRIWKHUHJXODWRULVIDFLQJWRZDUGV
WKHFDELQHWIURQWHDVLO\DFFHVVLEOHWKURXJKWKH
cabinet doors.
% ,QVWDOODPDQXDOVKXWRIIYDOYHLQWKHJDVOLQHLQD
location easily accessible through the cabinet doors.
& :KHQDOOFRQQHFWLRQVKDYHEHHQPDGHHQVXUHDOO
gas controls are in the off position and turn on the
main gas supply valve. Use a liquid leak detector
at all joints and connections to check for leaks in
the system.
*Teflon: Registered trademark of DuPont
5
GAS SUPPLY (cont.)
:KHQXVLQJSUHVVXUHVJUHDWHUWKDQSVLJWR
SUHVVXUHWHVWWKHJDVVXSSO\V\VWHPRIWKHUHVLGHQFH
GLVFRQQHFWWKHUDQJHWRSDQGLQGLYLGXDOVKXWRIIYDOYH
from the gas supply piping. When using pressures
RISVLJRUOHVVWRSUHVVXUHWHVWWKHJDVVXSSO\
V\VWHPVLPSO\LVRODWHWKHUDQJHWRSIURPWKHJDV
VXSSO\V\VWHPE\FORVLQJWKHLQGLYLGXDOVKXWRIIYDOYH
:KHQFKHFNLQJIRUSURSHURSHUDWLRQRIWKHUHJXODWRU
the inlet pressure must be at least 1” greater than the
operating (manifold) pressure as given on rating label
of product.
CONNECTOR HOOKUP
7<3,&$/,167$//$7,21:,7+12
OBSTRUCTION BELOW RANGETOP
A
B
C
D
F
G
E
A. ´137PDOHSLSH
thread
B. 5HJXODWRUSURYLGHGZLWK
unit:
2XWOHW´137
female pipe thread
,QOHW´137IHPDOH
pipe thread
C. Adapter
D. )OH[LEOHFRQQHFWRU
E. Adapter
F. 0DQXDOVKXWRIIYDOYH
G. *DVSLSH´RU´
A. ´137PDOHSLSHWKUHDG
B. EOERZ
C. Adapter
D. )OH[LEOHFRQQHFWRUDOORZV
SDVVDJHWKURXJKFDELQHWZDOO
E. Adapter
F. 5HJXODWRUSURYLGHGZLWKXQLW
2XWOHW´137IHPDOH
pipe thread
,QOHW´137IHPDOHSLSH
thread
G. Gas pipe
H. 0DQXDOVKXWRIIYDOYH
I. *DVSLSH´RU´
ALTERNATE INSTALLATION WITH
OBSTRUCTION BELOW RANGETOP
A
B
C
D
F
G
E
I
H
12 31-2000816 Rev. 0
Installation
6
ELECTRICAL CONNECTIONS
WARNING
Shock Hazard: This appliance must
be properly grounded. Failure to do so can result in
electric shock.
(OHFWULFDO5HTXLUHPHQWVYROW+HUW]SURSHUO\
JURXQGHGGHGLFDWHGFLUFXLWSURWHFWHGE\DDPSRU
DPSFLUFXLWEUHDNHURUWLPHGHOD\IXVH
NOTE:8VHRIDXWRPDWLFZLUHOHVVRUZLUHGH[WHUQDO
VZLWFKHVWKDWVKXWRIISRZHUWRWKHDSSOLDQFHDUHQRW
recommended for this product.
Grounding
7KHSRZHUFRUGRIWKLVDSSOLDQFHLVHTXLSSHGZLWK
DWKUHHSURQJJURXQGLQJSOXJZKLFKSOXJVLQWRD
VWDQGDUGWKUHHSURQJJURXQGLQJZDOOUHFHSWDFOHWR
minimize the possibility of electric shock hazard from
this appliance.
7KHFXVWRPHUVKRXOGKDYHWKHZDOOUHFHSWDFOHDQG
circuit checked by a qualified electrician to make sure
the receptacle is properly grounded.
:KHUHDVWDQGDUGWZRSURQJZDOOUHFHSWDFOHLV
HQFRXQWHUHGLWLVWKHSHUVRQDOUHVSRQVLELOLW\DQG
REOLJDWLRQRIWKHFXVWRPHUWRKDYHLWUHSODFHGZLWKD
SURSHUO\JURXQGHGWKUHHSURQJZDOOUHFHSWDFOH
'212781'(5$1<&,5&8067$1&(6&8725
REMOVE THE THIRD (GROUND) PRONG FROM
THE POWER CORD. DO NOT USE AN ADAPTER.
DO NOT USE AN EXTENSION CORD.
Ground Fault Circuit Interrupters (GFCI’s) are not
required or recommended for gas range receptacles.
3HUIRUPDQFHRIWKHUDQJHZLOOQRWEHDIIHFWHGLI
RSHUDWHGRQD*)&,SURWHFWHGFLUFXLWEXWRFFDVLRQDO
nuisance tripping of the GFCI breaker is possible.
Ensure proper
JURXQGH[LVWV
before use
7
CHECK BURNERS
WARNING
)LUHRU([SORVLRQ+D]DUG'RQRW
RSHUDWHWKHEXUQHUZLWKRXWDOOEXUQHUSDUWVLQSODFH
A. Burners3ODFHVXUIDFHEXUQHUVLQWRFRUUHVSRQGLQJ
positions on cooktop.
B. Caps3ODFHFDSVRQSURSHUVL]HEXUQHU
C. Grates7KHOHIWDQGULJKWJUDWHVDUH
interchangeable. Place the grates on the cooktop.
8
CHECK SURFACE BURNERS
Push and turn a knob to the LITE position. A clicking
sound indicates proper operation of the ignition
V\VWHP:KHQOLJKWLQJDQ\EXUQHUVSDUNVZLOODSSHDU
DWDOOEXUQHUVEXWJDVIORZVIURPRQO\WKHRQHVHOHFWHG
2QFHDLULVSXUJHGIURPWKHVXSSO\OLQHEXUQHUVKRXOG
OLJKWZLWKLQVHFRQGV$IWHUEXUQHUOLJKWVURWDWHWKH
knob out of the LITE position. Try each burner in
succession until all burners have been checked.
Quality of Flames
Determine the quality of flames visually. Normal
burner flames should look like (A) or (B).
/RQJEULJKW\HOORZIODPHVDUHQRWQRUPDO1RUPDO
IODPHVPD\VKRZVLJQVRIDQRUDQJHWLQWZKHQZHOO
heated or signs of flickering orange due to particles in
the gas or air.
(A) Soft blue flames—
Normal for natural gas
(B) Yellow tips on
outer cones—
Normal for propane (LP) gas
Burner Cap Not Properly Seated
Burner Cap Properly Seated
31-2000816 Rev. 0 13
Installation
FINALIZE INSTALLATION
Place the burner grates over the burners. The grates
should be seated and should not rock.
7KHJULGGOHLVVHFXUHGZLWKVFUHZV,WLVGHVLJQHGWR
be stationary and should not be removed.
7KHJULGGOHKDVWZROHYHOLQJVFUHZVEHQHDWKWKHUHDUIOXH
cover that can be used to adjust to the desired slope.
7KHWZRLQQHUVFUHZVDUHFODPSLQJVFUHZVIRU
VHFXULQJWKHJULGGOHLQSODFH/RRVHQWKHVHWZRVFUHZV
EHIRUHOHYHOLQJ'RQRWUHPRYHWKHVHWZRVFUHZV
7KHWZRRXWHUVFUHZVDUHOHYHOLQJVFUHZV'RQRW
UHPRYHWKHVHWZRVFUHZV7KH\FDQEHWXUQHGWROHYHO
WKHJULGGOHRUWRSURYLGHDIRUZDUGVORSHWRKHOSJUHDVH
DQGRLOVGUDLQDZD\IURPWKHIRRGEHLQJFRRNHG
$IWHUOHYHOLQJWKHJULGGOHKDQGWLJKWHQWKHFODPSLQJ
VFUHZVGRQRWRYHUWLJKWHQ
WHEN ALL HOOKUPS ARE
COMPLETED
Make sure all controls are left in the off position. Make
VXUHWKHIORZRIFRPEXVWLRQDQGYHQWLODWLRQDLUWRWKH
range is unobstructed.
Check that all packing materials and tape have been
UHPRYHG7KLVZLOOLQFOXGHWDSHRQPHWDOSDQHOXQGHU
FRQWURONQREVLIDSSOLFDEOHDGKHVLYHWDSHZLUH
WLHVFDUGERDUGDQGSURWHFWLYHSODVWLF)DLOXUHWR
remove these materials could result in damage to the
appliance once the appliance has been turned on and
surfaces have heated.
Griddle Flue Cover
&ODPSLQJ6FUHZV
/HYHOLQJ6FUHZV
14 31-2000816 Rev. 0
OPTIONAL ACCESSORIES12 HIGH BACKSPLASH
UX12BS36PSS, UX12BS48PSS Accessory Installation
This kit provides for the installation of a 12” high
backsplash for 36” Professional Ranges and Rangetops.
TOOLS AND MATERIALS REQUIRED
Ŷ*ORYHVWRSURWHFWDJDLQVWVKDUSHGJHV
Ŷ7DQG3KLOOLSV
VFUHZGULYHUV
Ŷ'ULOOZLWK´DQG
´ELWV
Ŷ6DIHW\JODVVHV
Ŷ/HYHO
Ŷ3HQFLO
This Kit Includes
Ŷ:DOOVXSSRUWSDQHO
Ŷ&RYHUSDQHO
Ŷ+DUGZDUHSDFNDJHZLWK
±6WDLQOHVV6WHHO7RU[
VHOIWDSSLQJVFUHZV
±3KLOOLSVSDQKHDGZRRG
VFUHZV
INSTALL 12” BACKSPLASH
WARNING
This backsplash must be securely
IDVWHQHGWRWKHZDOO)DLOXUHWRGRVRFRXOGUHVXOWLQ
damage or personal injury.
Ŷ,QVWDOODQGOHYHOWKHUDQJHRUUDQJHWRSDQGWKH
range hood according to the installation instructions.
Ŷ5HPRYHWKHEDFNVSODVKSDFNDJLQJDQGSURWHFWLYH
film.
Ŷ8VHDOHYHOWRSHQFLODKRUL]RQWDOOLQHRQWKHZDOO´
DERYHWKHUDQJHRUUDQJHWRS7KH´JDSDOORZVWKH
FRYHUSDQHOWRRYHUODSWKHZDOOVXSSRUWSDQHO
Ŷ/RFDWHZDOOVWXGVRQHDFKVLGH:KHUHVWXGVDUHQRW
DYDLODEOHSODQWRXVHZDOODQFKRUVQRWSURYLGHG
Ŷ$OLJQWKHZDOOVXSSRUWSDQHORQWKHPDUNHG
horizontal line and centered left to right.
Ŷ7KHZDOOVXSSRUWSDQHOPXVWEHVHFXUHGWRWKHZDOO
DWDOOFRUQHUV8VHZRRGVFUHZVSURYLGHGRUZDOO
anchors (not provided) to secure the support panel
WRWKHZDOO
Ŷ3ODFHWKHFRYHUSDQHORYHUWKHZDOOVXSSRUWSDQHO
DQGVHFXUHZLWK7RU[VFUHZVSURYLGHG,QVWDOO
VFUHZVRQHDFKVLGH
,QVWDOO:RRG6FUHZV
Wall Support Panel
Cover Panel
+DUGZDUH
Package
,QVWDOO:RRG6FUHZV
,QVWDOO7
6FUHZV
Wall
Support
Panel
Wall Support
Panel
Cover Panel
Center
$UURZ
´
31-2000816 Rev. 0 15
UXADBS36PSS, UXADBS48PSS Accessory Installation
ACCESSORIES—30” TO 36” ADJUSTABLE BACKSPLASH (not included)
Ŷ7KLVEDFNVSODVKDGMXVWVWRILWWKHVSDFHEHWZHHQ
WKHWRSRIWKHUDQJHDQGWKHERWWRPRIWKHKRRG
IURP´0LQWR´0D[KHLJKW
Ŷ0D[LPXPVKHOIORDGEHDULQJZHLJKWLVOEV
TOOLS AND MATERIALS REQUIRED
Ŷ*ORYHVWRSURWHFWDJDLQVWVKDUSHGJHV
Ŷ7DQG3KLOOLSVVFUHZGULYHUV
Ŷ'ULOOZLWK´DQG´ELWV
Ŷ6DIHW\JODVVHV
Ŷ/HYHO
Ŷ3HQFLO
This Kit Includes
Ŷ7RSZDOOVXSSRUW
Ŷ%RWWRPZDOOVXSSRUW
Ŷ7RSFRYHUZLWKVKHOI
Ŷ%RWWRPFRYHU
Ŷ+DUGZDUHSDFNDJHZLWK
±6WDLQOHVV6WHHO7RU[
VHOIWDSSLQJVFUHZV
±3KLOOLSVSDQKHDGZRRG
VFUHZV
3 Stainless Steel #2 truss head
VFUHZVIRUDOWHUQDWH
installation method)
INSTALL THE WALL SUPPORT PANELS
WARNING
7KHZDOOVXSSRUWSDQHOVPXVWEH
VHFXUHO\IDVWHQHGWRWKHZDOO)DLOXUHWRGRVRFRXOG
result in damage or personal injury.
IMPORTANT: This backsplash is designed to cover
WKHZDOOEHWZHHQWKHERWWRPRIWKHKRRGDQGWKHWRSRI
the range. The vent hood should be installed over the
rangetop or range before installing this backsplash.
Ŷ,QVWDOODQGOHYHOWKH5DQJH5DQJHWRSDFFRUGLQJWR
the product installation instructions.
Ŷ5HPRYHEDFNVSODVKSDFNDJLQJDQGSURWHFWLYHILOP
Ŷ/RFDWHZDOOVWXGVRQHDFKVLGH:KHUHVWXGVDUHQRW
DYDLODEOHSODQWRXVHZDOODQFKRUVQRWSURYLGHG
Ŷ8VHDOHYHOWRSHQFLOKRUL]RQWDOOLQHVRQWKHZDOO
RQH´EHORZWKHYHQWKRRGDQGWKHRWKHU´
DERYHWKH5DQJH5DQJHWRS7KLV´VSDFHDOORZV
WKHFRYHUSDQHOVWRRYHUODSWKHZDOOVXSSRUWV
Ŷ6HFXUHWKHWRSZDOOVXSSRUWSDQHOWRWKHZDOOZLWK
ZRRGVFUHZVWKURXJKWKHRXWHUPRVWVWXGV
Ŷ8VHZRRGVFUHZVWRVHFXUHWKHERWWRPZDOOVXSSRUW
panel. The center slot should be positioned at the top.
7KHJDSEHWZHHQWKHWRSDQGERWWRPVXSSRUWSDQHOV
ZLOOEHFRYHUHGE\WKHWRSFRYHUZLWKVKHOI
+DUGZDUH
Package
Top Cover
ZLWK6KHOI
Bottom Cover
Bottom Wall Support
Top Wall
Support
´
Secure the
top panel to
WKHZDOOZLWK
ZRRGVFUHZV
´
Secure the
bottom panel to
WKHZDOOZLWK
ZRRGVFUHZV
Wood
6FUHZV
Center
$UURZ
Wood
6FUHZV
16 31-2000816 Rev. 0
UXADBS36PSS, UXADBS48PSS Accessory Installation
INSTALL COVER PANELS
See alternate method if side access is blocked.
Ŷ+ROGWKHERWWRPFRYHURYHUWKHERWWRPVXSSRUW
ZKLOHGULYLQJRQHVFUHZSURYLGHGLQWRHDFKVLGH
Ŷ3ODFHWKHWRSFRYHUZLWKVKHOIRYHUWKHWRSZDOO
VXSSRUW,I\RXKDYHDFFHVVWRWKHVLGHVVHFXUHWKH
SDQHOZLWKWZRVFUHZVRQHDFKVLGH
Ŷ6HFXUHWKHWRSFRYHUZLWKVKHOIWRWKHWRSVXSSRUW
ZLWKVFUHZVWKURXJKWKHIURQWRIWKHSDQHODWWKHWRS
FRUQHUV8VHRQHVFUHZRQHDFKVLGH
INSTALL COVER PANELS (cont.)
ALTERNATE METHOD: When side access is blocked
Ŷ,QVWDOOERWWRPFRYHURYHUWKHERWWRPVXSSRUWZKLOH
GULYLQJRQHVFUHZLQWRHDFKVLGH
Ŷ+ROGWRSFRYHULQSODFHZKLOHPDUNLQJVFUHZORFDWLRQV
MXVWEHORZVKHOIVXSSRUWDQGRQWRERWWRPFRYHU
Ŷ5HPRYHWKHVKHOIDQGGULOOD´GLDPHWHUKROHLQ
WKHSHQFLOPDUNHGORFDWLRQV
Ŷ0RXQWWKHWRSFRYHURYHUWKHWRSVXSSRUWDQG
VHFXUHWKHIURQWFRYHUZLWKVFUHZVWKURXJKWKH
drilled holes on each side.
Ŷ,QVWDOOVFUHZVWKURXJKHDFKWRSFRUQHU
0DUN6FUHZ
Locations for
Alternate Method
ACCESSORIES—30” TO 36” ADJUSTABLE BACKSPLASH (not included) (Cont.)
Install
6FUHZ
Cover Panel
Install
6FUHZ
,QVWDOO&RUQHU6FUHZV
,QVWDOO6FUHZ
on Each Side
Shelf
,QVWDOO6FUHZLQ7RS&RUQHURQ(DFK6LGH
31-2000816 Rev. 0 17
Notes
18 31-2000816 Rev. 0
Notes
31-2000816 Rev. 0 19
Notes
20 31-2000816 Rev. 0
NOTE: :KLOHSHUIRUPLQJLQVWDOODWLRQVGHVFULEHGLQWKLVERRN
VDIHW\JODVVHVRUJRJJOHVVKRXOGEHZRUQ
NOTE: Product improvement is a continuing endeavor at
*($SSOLDQFHV7KHUHIRUHPDWHULDOVDSSHDUDQFHDQG
VSHFLILFDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH
3ULQWHGLQ0H[LFR
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

GE CGU486P2TS1 Guide d'installation

Taper
Guide d'installation