Venmar 45110 Mode d'emploi

Taper
Mode d'emploi

Ce manuel convient également à

17/11/03 03346
MANUEL DE L’UTILISATEUR
Lisez et conservez ces instructions
Fonctionnement de l’appareil
CONSTRUCTO 1.5 ET 2.0
USER MANUAL
Read and save these instructions
Operating the unit model:
CONSTRUCTO 1.5 AND 2.0
17/11/03 03346
CONGRATULATIONS! You have made an excellent choice!
We have prepared this Operating Guide especially for you. Read it carefully to ensure you
obtain full benefit from your Heat Recovery Ventilator unit.
A DESCRIPTION OF UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
B FUNCTION OF THE HEAT RECOVERY VENTILATOR . . . . 3
C CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
D OPTIONAL CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
E MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
F TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
WARNING
1- Some activities creats dust or vapors which may damage your unit.You must therefore turn off
and unplug your unit in the following situations:
major renovation work
housing construction
• sanding (e.g. gypsum joints, etc.)
• varnishing
2- During very heavy snow storms, the unit should also be turned off to avoid problems caused
by snow entering the unit even if it is equipped with anti-gust intake hood.
3- During maintenance and repairs, the unit must always be turned off, then unplugged.
4- Power disturbances or very short power failures may cause the electronic control microproces-
sor to malfunction. If it does, disconnect the power plug from the outlet and wait approximately
30 seconds, then plug it back in to resume operation.
TABLE OF CONTENTS
2
FÉLICITATIONS ! Vous avez fait un excellent choix !
Nous avons préparé, à votre intention, ce guide de fonctionnement. Lisez-le attentivement
pour vous assurer le plein rendement de votre Ventilateur à récupération de chaleur.
A DESCRIPTION DE L’APPAREIL . . . . . . . . . . . . . . . . . . . . . . 3
B RÔLE DU RÉCUPÉRATEUR DE CHALEUR . . . . . . . . . . . . 3
C CONTRÔLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
D CONTRÔLES OPTIONNELS . . . . . . . . . . . . . . . . . . . . . . . . . 5
E ENTRETIEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
F DÉPANNAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
ATTENTION
1- Certaines activités génèrent des poussières ou des vapeurs qui peuvent endommager votre
appareil. Il faut donc toujours éteindre et débrancher lors de :
• rénovation (travaux majeurs)
• construction de la maison
• sablage de joints de gypse
• travaux de vernissage
2- Lors de grosses tempêtes, l’appareil devrait aussi être éteint pour éviter les problèmes causés
par l’introduction de neige même si ce dernier est muni d’une bouche anti-rafales.
3- Lors de réparation ou d’entretien, toujours éteindre et débrancher votre appareil.
4- Comme le système de contrôle électronique de l’unité utilise un micro-processeur, il peut ne pas
fonctionner correctement à cause de parasites externes ou de très courtes pannes de courant.
Dans un tel cas, débranchez le cordon d’alimentation de la prise de courant, et attendre environ
30 secondes avant de le remettre en marche pour reprendre les opérations.
TABLE DES MATIÈRES
2
1- Filtre
2- Ventilateur
3- Bac à condensation
4- Noyau de récupération de chaleur
SPÉCIFICATIONS
Votre système de ventilation aidera
à éliminer les problèmes de mau-
vaise qualité d’air en évacuant l’air
vicié et humide de la maison à
l’extérieur et en le remplaçant par de
l’air frais provenant de l’extérieur. En
éliminant ainsi l’accumulation de
polluants et d’humidité, il maintient
une qualité d’air optimale et une
humidité relative idéale.
L’appareil, doté d’un noyau de
récupération de chaleur, permet de
réduire les frais reliés à la ventilation
l’hiver.
B. RÔLE DU RÉCUPÉRATEUR DE CHALEUR
Modèle
Constructo 1.5 Constructo 2.0
Largeur 30 1/4” (768 mm) 30 1/4” (768 mm)
Hauteur 16 1/2” (419 mm) 16 1/2” (419 mm)
Profondeur 17 1/4” (438 mm) 17 1/4” (438 mm)
Poids 66 lb (30 kg) 68 lb (31 kg)
Amérique du Nord
Alimentation électrique 120 Volts, 60 Hz 120 Volts, 60 Hz
Consommation électrique 150 Watts 240 Watts
International
Alimentation électrique 100 Volts, 50/60 Hz 100 Volts, 50/60 Hz
Consommation électrique 115 Watts 240 Watts
Alimentation électrique 230-240 Volts, 50 Hz 230-240 Volts, 50 Hz
Consommation électrique 144 Watts 193 Watts
A. DESCRIPTION DE L’APPAREIL
3
Montré comme étant raccordé à un système de
chauffage à air forcé, peut aussi être installé indépen-
demment.
1- Filters
2- Fans
3- Condensation tray
4- Heat recovery core
SPECIFICATIONS
Your ventilation system will help to
eliminate poor air quality problems
by drawing the stale and humid air
out of the house and replacing it
with fresh outside air. By eliminating
accumulated pollutants and humidi-
ty, it maintains an optimum air quali-
ty and an ideal relative humidity.
The unit is also equipped with a heat
recovery core which reduces venti-
lation costs in winter.
* Shown with a forced air heating system, can also operate on its own.
B. FUNCTION OF THE HEAT RECOVERY VENTILATOR
Model
Constructo 1.5 Constructo 2.0
Width 30 1/4” (768 mm) 30 1/4” (768 mm)
Height 16 1/2” (419 mm) 16 1/2” (419 mm)
Depth 17 1/4” (438 mm) 17 1/4” (438 mm)
Weight 66 lb. (30 kg) 68 lb. (31 kg)
North America
Electrical supply 120 Volts, 60 Hz 120 Volts, 60 Hz
Power consumption 150 Watts 240 Watts
International
Electrical supply 100 Volts, 50/60 Hz 100 Volts, 50/60 Hz
Power consumption 115 Watts 240 Watts
Electrical supply 230-240 Volts, 50 Hz 230-240 Volts, 50 Hz
Power consumption 144 Watts 193 Watts
A. DESCRIPTION OF UNIT
3
HEAT RECOVERY
Units equipped with a heat recovery core can reduce ventilation costs in winter. The unit draws the
heat from the stale and humid air before it is released and uses it to heat the air coming in from
outside.The recovery core is designed in such a way that the stale air is never mixed with the fresh
air.
Example: (in winter)
DEFROSTING
When the outside temperature is below -5
o
C (23
o
F), heat recovery creates frost in the core.To main-
tain its proper operation, the unit is programmed to defrost the recovery core. The defrosting fre-
quency varies according to outside temperature. Defrosting lasts 6 minutes (or 10 minutes if set on
“Extended Defrost”). During the defrost cycle the unit shifts to maximum speed and the dampers
close.
After defrosting, the unit returns to the operating mode selected by the user.
3-POSITION SWITCH
Location: Located on the side of unit.
Purpose: To adjust air supply and reduce condensation on windows
How to operate the unit on a daily basis
Select “LOW” or “HIGH” speed:
Select “LOW SPEED” for normal daily operation.
Select “HIGH SPEED” for excess pollutants and humidity (parties, odors, smoke, etc.)
How to turn the unit off:
Push switch to the “REMOTE” position.
N.B.: Optional controls can still activate the unit, even when it is in the “REMOTE” position.You must
therefore unplug the unit to be absolutely sure it is off.
C. CONTROL
B. FUNCTION OF THE HEAT RECOVERY VENTILATOR (continued)
4
Exhaust air to outside 6
o
C/43
o
F
Fresh air from outside 0
o
C/32
o
F
Fresh air to building 16
o
C/61
o
F
Exhaust air from building 22
o
C/72
o
F
RÉCUPÉRATEUR DE CHALEUR
Les appareils dotés d’un noyau de récupération de chaleur permettent de réduire, en hiver, les frais
reliés à la ventilation. En effet, l’appareil retire la chaleur contenue dans l’air vicié et humide avant
qu’il ne soit évacué, et réchauffe ainsi l’air qui provient de l’extérieur. Le noyau de récupération est
conçu de façon à ce que l’air vicié ne se mélange jamais avec l’air frais.
Exemple : (en hiver)
LE DÉGIVRAGE
Lorsque la température extérieure est inférieure à -5
o
C (23
o
F), la récupération de chaleur amène la
formation de givre dans le noyau de récupération. Pour son bon fonctionnement, l’appareil procède
par lui-même au dégivrage du noyau de récupération. La fréquence de dégivrage varie selon la
température extérieure. La durée d’un dégivrage est de 6 minutes (ou 10 minutes en mode de
« Dégivrage Étendu »). L’appareil passe alors en vitesse maximale et les volets se ferment.
Après le dégivrage, l’appareil retourne au mode de fonctionnement choisi par l’utilisateur.
INTERRUPTEUR 3 POSITIONS
Localisation : Situé sur le côté de l’appareil
Fonction : Permet d’ajuster l’alimentation d’air et de
réduire la condensation dans les fenêtres.
Comment faire fonctionner l’appareil quotidiennement :
Sélectionnez la basse vitesse ou la haute vitesse :
Choisissez l’option basse vitesse dans le cas d’une opération normale quotidienne (24 heures
par jour toute l’année).
Choisissez l’option haute vitesse lorsqu’il y a excès de polluants ou d’humidité (fêtes, odeurs
de fumée, etc.).
Comment éteindre l’appareil :
Poussez l’interrupteur à la position « ARRÊT ».
N.B. : Les contrôles optionnels peuvent toujours activer l’appareil même s’il est en position
« ARRÊT ». Donc, pour une mise en arrêt plus sûre, il faut débrancher l’appareil.
C. CONTRÔLE
B. RÔLE DU RÉCUPÉRATEUR DE CHALEUR (suite)
4
Évacuation d’air vicié 6
o
C/43
o
F
Aspiration d’air frais 0
o
C/32
o
F
Distribution d’air frais 16
o
C/61
o
F
Aspiration d’air vicié 22
o
C/72
o
F
D. 1-CONTRÔLE CONSTRUCTO
Important :
Pour faire fonctionner votre appareil à l’aide de ce contrôle, l’interrupteur 3 positions, situé sur le
côté de l’appareil, doit être à la position ARRÊT.
Localisation : situé à l’endroit de la maison le plus fréquenté.
Fonction : permet d’ajuster l’alimentation d’air et de réduire la condensation se formant sur
les fenêtres.
Ajustez le contrôle d’alimentation d’air :
a) Sélectionnez la vitesse « MIN. » ou « MAX. »
à l’aide du bouton A (schéma ci-contre).
Choisissez l’option « MIN. » (vitesse
minimum) dans le cas d’une opération
normale quotidienne (24 heures par jour,
toutes l’année).
Choisissez l’option « MAX. » (vitesse
maximum) lorsqu’il a excès de polluants ou
d’humidité (fêtes, odeurs de fumée, etc.).
b) Pour éteindre l’appareil, placez le sélecteur
à la position « OFF ». Les contrôles optionnels
seront cependant toujours en fonction.
Ajustez le contrôle d’humidité :
Réglage pour la période d’été :
Durant cette période il n’y a normalement aucune condensation dans vos fenêtres, ce qui rend
l’usage du contrôle d’humidité inutile pendant quelques mois. Réglez le bouton B à la position
« ÉTÉ » durant toute la période estivale.
Réglage pour les périodes d’automne, d’hiver et de printemps :
MÉTHODE 1 (simple et rapide pour les nouveaux usagers) :
a) Déterminez approximativement la température extérieure du jour.
b) Réglez le bouton B à cette température.
Suivez cette méthode pendant environs un mois avant d’essayer la méthode 2 proposée ci-desous.
MÉTHODE 2 (pour un meilleur ajustement) :
Utilisez la MÉTHODE 2 (étapes a à f ci-dessous) si la condensation persiste dans les fenêtres
après avoir suivi la MÉTHODE 1 pendant au moins un mois. Puisque les besoins en ventilation
varient d’une maison à l’autre (dépendamment des habitudes de cuisson, de la fréquence des
douches, lavages, de la construction des fenêtres, etc.), il est possible que l’ajustement à l’aide
de la température extérieure ne puisse pas résoudre le problème de condensation dans votre
maison.
a) Sélectionnez l’option « MIN. »
b) Tournez le bouton B dans le sens des aiguilles d’une montre jusqu’à ce que vous
entendiez un déclic.
D. CONTRÔLES OPTIONNELS
5
D. 1-CONSTRUCTO CONTROL
Important:
To operate your system with this control, the 3-position switch located on the side of the unit must
be set to “REMOTE” position.
Location: Located in the busiest area of the house
Purpose: To adjust air supply and select desired indoor humidity level.
Adjusting the AIR SUPPLY CONTROL:
a) Select speed “MIN.” or “MAX. using switch A (as
shown on diagram).
Select “MIN.” (minimum speed) for normal
daily operation (24 hours a day all year round).
Select “MAX.” (maximum speed) for excess
pollutants and humidity (parties, odors,
smoke, etc.)
b) To turn the unit off, place selector at the “OFF”
position. Optional controls however may still be
active.
Adjusting the HUMIDITY CONTR
OL:
Setting during the summer months:
Normally there is no condensation on your windows during this period which therefore eliminates
the need of the humidity control. Set knob B at the “SUMMER” position during this period.
Setting during the fall, winter and spring months:
• METHOD 1 (fast and simple for new users):
a) Determine approximately the outside daytime temperature.
b) Set knob B to this temperature.
Continue using this method for about a month before trying method 2 suggested below.
• METHOD 2 (more precise adjustment):
Use METHOD 2 (steps a to f below) if there is condensation on your windows after using
METHOD 1 for at least a month. As ventilation needs vary from one house to another (depend-
ing on cooking habits, frequency of showers, washing, window construction, etc.), an adjustment
based on outside temperature may not adequately solve the condensation problem in your house.
a) Select “MIN.
b) Turn knob B clockwise until you hear a click.
c) Turn knob B a notch below the click.
d) Twelve to 24 hours later, check if there is still condensation on the windows.
e) If there is, repeat steps b, c, d above (until desired results are obtained).
D. OPTIONAL CONTROLS
5
f) Compare the 2 values: that obtained with METHOD 1 and that obtained with METHOD 2. Use
the variance for future reference. For example: If there is a 3 degree variance, you can conclude
that, for your house, an adjustment of 3 degrees below the outside temperature is required for
optimum condensation control.
WARNING: Do not select a temperature below - 20
o
C. This could lead to excessive dryness
in the air causing discomfort for the occupants.
D.2-DEHUMIDISTAT
Location: Located in the bathroom or in other
locations where there is temporary
excess humidity.
Purpose: To eliminate excess humidity
produced by showers or other
periodic activities producing humidity.
In the fall, winter and spring:
Adjust knob to the desired maximum humidity level.
WARNING: Do not select a humidity level below 30%.
This could lead to excessive dryness in
the air causing discomfort for the occupants.
In the summer:
Adjust knob to the “SUMMER” position.
D.3-TIMERS
Location: Located in the bathroom or in other locations where there is temporary excess humidi-
ty or pollutants.
Purpose: To eliminate excess humidity produced by showers or other periodic activities produc-
ing pollutants.
20 minutes push-button timer:
Set the push-button to “ON”: The fan motor will then operate at high
speed for 20 minutes and the indicator will light up. (To stop activation,
push on time, the unit will then get back to previous selection.)
60 minutes timer:
This control makes the system operate at high speed for periods varying
from 10 to 60 minutes.
D. OPTIONAL CONTROLS (continued)
6
c) Tournez le bouton B un degré plus bas que la position du déclic.
d) 12 à 24 heures plus tard, vérifiez si la condensation dans les fenêtres persiste.
e) Si c’est le cas, répétez les étapes b, c, d ci-dessus jusqu’à l’obtention du résultat escompté.
f) Comparez les 2 valeurs : celle obtenue à la MÉTHODE 1 et celle obtenue à la MÉTHODE
2. Servez-vous de la différence pour références futures. Exemple : Si la différence est de
3 degrés, vous pouvez donc conclure que, pour votre maison, un ajustement de 3 degrés
plus bas que la température extérieure est nécessaire pour permettre un contrôle optimal
de la condensation.
ATTENTION :
Ne pas sélectionner la température en deçà de -20
o
C; cela pourrait provoquer
un dessèchement trop prononcé de l’air qui nuirait au confort des occupants
.
D.2-DESHUMIDISTAT
Localisation : Situé dans la salle de bains ou à tout
autre endroit où il y a production
périodique de polluants ou d’excès
d’humidité.
Fonction : Permet d’éliminer les excès d’humidité
produits lors de douches ou autres
activités produisant des polluants de
façon périodique.
Régla
ge pour les périodes d’automne, d’hiver et du
printemps :
Réglez le bouton au niveau d’humidité maximum désiré.
MISE EN GARDE : Ne pas sélectionner un niveau d’humidité en deçà de 30 %. Cela pourrait
provoquer un dessèchement trop prononcé de l’air qui nuirait au confort des occupants.
Réglage pour la période d’été :
Placez le bouton à la position « ÉTÉ »
D.3-MINUTERIES
Localisation : Situés dans la salle de bains ou à tout autre endroit où il y a production de
polluant ou d’excès d’humidité périodiques.
Fonction : Permettent d’éliminer les excès d’humidité produits lors de douches ou autres
activités produisant des polluants de façon périodique.
Comment utiliser le bouton-poussoir 20 minutes :
Pressez le bouton-poussoir : le moteur de ventilation opérera alors à
haute vitesse pendant 20 minutes. (pour arrêter l’activation, appuyez une
fois. L’appareil revient alors à la sélection précédente.)
•Minuterie 60 minutes :
Ce contrôle fait fonctionner l’appareil a haute vitesse pendant des
périodes variant de 10 à 60 minutes.
D. CONTRÔLES OPTIONNELS (suite)
6
E.1 RÉGULIER
Filtres :
Les filtres à air sont lavables. Dans des conditions normales d’utilisation, nous recommandons de
les laver à tous les trois (3) mois.
Passez l’aspirateur sur les filtres pour enlever la plus grande partie de dépôt de poussière.
Puis les laver à l’eau et savon doux.
Noyau :
Le noyau de la récupération doit être manipulé avec soin. Nous vous recommandons de le laver
une fois l’an, avant la saison d’utilisation intensive, afin d’assurer la bonne condition des surfaces
de polypropylène constituant le noyau. Laissez tremper le noyau de récupération au moins trois (3)
heures dans une solution d’eau tiède et de savon doux. Rincez à jet d’eau.
REMARQUE : L’eau très chaude et un savon fort endommageraient le noyau de récupération.
Grille :
Vérifiez le grillage de la bouche de prise d’air extérieure régulièrement et nettoyez-le au besoin. Par
temps très froid, il peut s’accumuler de la glace sur le grillage d’où l’importance de vérifier la prise
d’air régulièrement.
Moteur :
La lubrification des moteurs est faite à l’usine. Celui-ci est lubrifié à vie. Ne pas lubrifier les
coussinets.
E.2 PROLONGÉ
L’entretien annuel devrait inclure :
1) Nettoyage des filtres, du noyau de récupération de chaleur et de l’entrée / sortie extérieures.
2) Nettoyage des pales de chacune des roues du ventilateur.
3) Nettoyage du bac de condensation avec de l’eau savonneuse et vérification de l’écoulement du
drain.
NOTE :
Informez-vous auprès de votre installateur pour un contrat d’entretien annuel.
E. ENTRETIEN
7
E.1 REGULAR
Air filters:
The air filters are washable. Under normal conditions, we recommend that they be washed every
3 months.
Use a vacuum cleaner to remove the heaviest portion of accumulated dust.
Then wash in water and mild soap.
Heat Recovery Core:
The heat recovery core must be handled with care. We recommend to wash it once a year, at the
end of summer, in order to insure maximum efficiency of the plastic partitions.
Allow the heat recovery core to soak for 3 hours in a solution of warm water and mild soap. Rinse
under a heavy stream of water.
IMPORTANT NOTE: Hot water and a strong detergent will damage the heat recovery core.
Intake hood:
Regularly check the screen on the exterior intake hood and clean when necessary. Also check dur-
ing very cold weather because ice may build up on the screen located at the exterior intake hoods.
Motor:
The motors are factory lubricated for life. Do not oil bushings.
E.2 PROLONGED
Annual service should include:
1) Cleaning filters, heat recovery core and the exterior air intake hood.
2) Cleaning the blades of the blower wheels.
3) Cleaning the condensation tray with soapy water (make certain that the drain is not clogged).
NOTE:
Ask your intaller for an annual service contract.
E. MAINTENANCE
7
If you think you unit is malfunctioning, check some of the following.
If the problem continues, contact your installer at the telephone number and address indicated
below or call one of the following numbers for authorized service centre nearest you:
1-800-567-3855 (Canada and U.S.A.)
1-819-477-6226 (International)
ADDRESS OF YOUR INSTALLER
TYPE OF PROBLEM TRY THIS...
1 Nothing works. See if the unit is plugged in.
See if the unit is receiving power from the house circuit
breaker.
2 Condensation on windows.
(air too humid)
Adjust the humidity control knob as per instructions (see
section D).
Operate the unit at maximum speed (MAX.) during
activities generating excess humidity (family gatherings,
extra cooking, etc.).
Leave curtains half-open to allow air circulation.
Store all firewood in a close room with a dehumidifier or
in a well ventilated room or store the wood outside.
Do not adjust the thermostat of your heating system
below 18
o
C (64
o
F).
3 Air too dry Do not adjust your humidity control below -20
o
C (-4
o
F).
Operate the unit at low speed (MIN.).
Temporarily use a humidifier.
4 Air too cold at the air supply grille Make sure the stale air exhaust hood outside the house
is not blocked.
Operate the unit at low speed (MIN.).
Have the system’s balancing checked.
Have the unit’s defrosting system checked.
Install a duct heater.
F. TROUBLESHOOTING
8
Dans le cas où vous soupçonnez un mauvais fonctionnement de votre système, voici quelque
points à vérifier.
Si le problème persiste, contactez soit votre installateur, dont le numéro de téléphone et l’adresse
figurent ci-dessous, ou appelez à un des numéros suivants pour connaître le centre de service
autorisé le plus près de chez vous :
1-800-567-3855 (Canada et U.S.A.)
1-819-477-6226 (International)
ADRESSE DE VOTRE INSTALLATEUR
PROBLÈME ESSAYEZ CECI...
1 Rien ne fonctionne. Vérifiez si l’appareil est branché.
Vérifiez le disjoncteur de la maison alimentant l’appareil.
2 Vitres embuées.
(air trop humide)
Ajustez le bouton du contrôle d’humidité selon les
recommandations (section D).
Faites fonctionner l’appareil à vitesse maximum (MAX.)
lors d’activités produisant un excès d’humidité (rassem-
blements de famille, activités culinaires prolongées, etc.)
Laissez les rideaux entrouverts pour laisser ciculer l’air.
Rangez le bois de chauffage dans une pièce fermée
dotée d’un déshumidificateur ou dans une pièce bien
aérée avec de l’air extérieur ou rangez-le à l’extérieur.
N’ajustez pas le thermostat de votre système de
chauffage en deçà de 18
o
C (64
o
F).
3 Air trop sec.
Ne sélectionnez pas une température en deçà de -20
o
C
(-4
o
F) sur le contrôle d’humidité.
Faites fonctionner l’appareil à baisse vitesse (MIN).
Utilisez temporairement un humidificateur.
4 Air trop froid à la grille de distribution. Assurez-vous que le grillage de la bouche d’évacuation
d’air se trouvant à l’extérieur de la maison n’est pas
obstrué.
Faites fonctionner l’appareil à la vitesse minimum (MIN.).
Faites vérifier le balancement du système.
Faites vérifier le système de dégivrage de l’appareil.
Installez un chauffage d’appoint.
F. DÉPANNAGE
8
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Venmar 45110 Mode d'emploi

Taper
Mode d'emploi
Ce manuel convient également à

dans d''autres langues