RIDGID OF45200SS-R175RNF-R5025LF Manuel utilisateur

Catégorie
Compresseurs d'air
Taper
Manuel utilisateur
OPERATOR’S MANUAL
MANUEL D’UTILISATION
MANUAL DEL OPERADOR
4.5 GALLON PORTABLE AIR COMPRESSOR
COMPRESSEUR D’AIR PORTABLE DE 17 LITRES
(4,5 GALLONS)
COMPRESOR DE AIRE PORTÁTIL DE 17 LITROS
(4,5 GALONES)
OF45200SS
To register your RIDGID
product, please visit:
http://register.RIDGID.com
Pour enregistrer votre
produit de RIDGID,
s’il vous plaît la visite :
http://register.RIDGID.com
Para registrar su producto
de RIDGID, por favor visita:
http://register.RIDGID.com
WARNING:
To reduce the risk of injury, the
user must read and understand the
operator’s manual before using this
product.
ADVERTENCIA:
Para reducir el riesgo de
lesiones, el usuario debe leer
y comprender el manual del
operador antes de usar este
producto.
AVERTISSEMENT :
Pour réduire les risques de
blessures, l’utilisateur doit lire
et veiller à bien comprendre
le manuel d’utilisation avant
d’employer ce produit.
TABLE OF CONTENTS
****************
General Safety Rules .......................2-3
Air Compressor Safety Warnings ....3-4
Symbols ...........................................5-6
Electrical ............................................. 7
Glossary of Terms ...............................8
Features ..............................................9
Assembly ............................................ 9
Operation .....................................10-12
Maintenance ..................................... 13
Troubleshooting ................................ 14
Illustrations ..................................15-16
Parts Ordering/Service ....... Back Page
TABLE DES MATIÈRES
****************
Règles de sécurité générales
........................................................2-3
Avertissements de sécurité relatifs
compressuer d’aire .........................3-4
Symboles .........................................5-6
Caractéristiques électriques ...............7
Glossary of Terms ...............................8
Caractéristiques .................................9
Assemblage ........................................9
Utilisation .....................................10-12
Entretien ...........................................13
Troubleshooting ................................ 14
Illustrations ..................................15-16
Commande de pièces /
réparation ..........................Page arrière
ÍNDICE DE CONTENIDO
****************
Reglas de seguridad
generales .........................................2-3
Advertencias de seguridad
compresor aire ................................3-4
Símbolos .........................................5-6
Aspectos eléctricos ............................ 7
Glossary of Terms ...............................8
Características ...................................9
Armado ............................................... 9
Funcionamiento ...........................10-12
Mantenimiento ..................................13
Troubleshooting ................................ 14
Ilustraciones ................................15-16
Pedidos de piezas /
servicio .......................... Pág. posterior
SAVE THIS MANUAL FOR
FUTURE REFERENCE
CONSERVER CE MANUEL
POUR FUTURE RÉFÉRENCE
CONSERVER CE MANUEL
POUR FUTURE RÉFÉRENCE
2 – English
GENERAL SAFETY RULES
WARNING:
Read and understand all instructions. Failure
to follow all instructions listed below may result
in electric shock, fire, and/or serious personal
injury.
SAVE THESE INSTRUCTIONS
WORK AREA
Keep your work area clean and well lit. Cluttered
benches and dark areas invite accidents. Floor must not
be slippery from wax or dust.
Do not operate air compressors in explosive atmo-
spheres, such as in the presence of flammable liquids,
gases, or dust. Power tools create sparks which may
ignite the dust or fumes.
Keep bystanders, children, and visitors away while
operating an air compressor. Distractions can cause you
to lose control.
Operate air compressor in an open area at least 18 in.
away from any wall or object that could restrict the
flow of fresh air to ventilation openings.
ELECTRICAL SAFETY
Avoid body contact with grounded surfaces such as
pipes, radiators, ranges, and refrigerators. There is an
increased risk of electric shock if your body is grounded.
Don’t expose air compressors to rain or wet condi-
tions. Water entering an air compressor will increase the
risk of electric shock.
Do not abuse the cord. Never use the cord to carry
the air compressor or pull the plug from an outlet.
Keep cord away from heat, oil, sharp edges, or moving
parts. Replace damaged cords immediately. Damaged
cords increase the risk of electric shock.
When operating an air compressor outside, use an out-
door extension cord marked “W-A” or “W”. These cords
are rated for outdoor use and reduce the risk of electric shock.
PERSONAL SAFETY
Eye protection which conforms to ANSI specifications
and provides protection against flying particles both
from the FRONT and SIDE should ALWAYS be worn by
the operator and others in the work area when load-
ing, operating, or servicing this product. Eye protection
is required to guard against flying fasteners and debris,
which could cause severe eye injury.
The employer and/or user must ensure that proper
eye protection is worn. We recommend a Wide Vision
Safety Mask for use over eyeglasses or standard safety
glasses that provide protection against flying particles
both from the front and side. Always use eye protection
which is marked to comply with ANSI Z87.1.
Additional safety protection will be required in some
environments. For example, the working area may
include exposure to a noise level which can lead to hear-
ing damage. The employer and user must ensure that any
necessary hearing protection is provided and used by the
operator and others in the work area. Some environments
will require the use of head protection equipment. When
required, the employer and user must ensure that head
protection marked to comply with ANSI Z89.1 is used.
Stay alert, watch what you are doing, and use com-
mon sense when operating the air compressor. Do
not use product while tired or under the influence of
drugs, alcohol, or medication. A moment of inattention
while operating an air compressor may result in serious
personal injury.
Dress properly. Do not wear loose clothing or jewelry.
Contain long hair. Keep your hair, clothing, and gloves
away from moving parts. Loose clothes, jewelry, or long
hair can be caught in moving parts.
Do not overreach. Keep proper footing and balance
at all times. Proper footing and balance enables better
control of the product in unexpected situations.
Use safety equipment. Always wear eye protection.
Dust mask, nonskid safety shoes, hard hat, or hearing
protection must be used for appropriate conditions.
Do not use on a ladder or unstable support. Stable
footing on a solid surface enables better control of the
air compressor in unexpected situations.
AIR COMPRESSOR USE AND CARE
Do not exceed the pressure rating of any component
in the system.
Protect material lines and air lines from damage or
puncture. Keep hose and power cord away from sharp
objects, chemical spills, oil, solvents, and wet floors.
Check hoses for weak or worn condition before each
use, making certain all connections are secure. Do not
use if defect is found. Purchase a new hose or notify an
authorized service center for examination or repair.
Release all pressures within the system slowly. Dust
and debris may be harmful.
Store idle air compressors out of the reach of children
and other untrained persons. Air compressors are dan-
gerous in the hands of untrained users.
Maintain air compressors with care. Follow mainte-
nance instructions. Properly maintained products are
easier to control.
Check for misalignment or binding of moving parts,
breakage of parts, and any other condition that may
affect the product’s operation. If damaged, have the
air compressor serviced before using. Many accidents
are caused by poorly maintained products.
3 – English
Know your air compressor. Read operator’s manual
carefully. Learn its applications and limitations, as well
as the specific potential hazards related to this product.
Following this rule will reduce the risk of electric shock,
fire, or serious injury.
Drain tanks of moisture after each day’s use. If unit will
not be used for a while, it is best to leave drain valve open
until such time as it is to be used. This will allow moisture
to completely drain out and help prevent corrosion on the
inside of tanks.
Risk of fire or explosion. Do not spray flammable liquid
in a confined area. Spray area must be well ventilated. Do
not smoke while spraying or spray where spark or flame
is present. Keep compressors as far from the spraying
area as possible, at least 20 feet from the spraying area
and all explosive vapors.
Risk of bursting. Do not adjust regulator to result in
output pressure greater than marked maximum pressure
of attachment. Do not use at pressure greater than 150 psi.
If connected to a circuit protected by fuses, use time-
delay fuses with this product.
To reduce the risk of electric shock, do not expose to
rain. Store indoors.
Inspect tanks yearly for rust, pin holes, or other
imperfections that could cause it to become unsafe.
Never weld or drill holes in the air tanks.
Make sure the hose is free of obstructions or snags.
Entangled or snarled hoses can cause loss of balance or
footing and may become damaged.
Use the air compressor only for its intended use. Do
not alter or modify the unit from the original design
or function.
Always be aware that misuse and improper handling of
this product can cause injury to yourself and others.
GENERAL SAFETY RULES
SPECIFIC SAFETY RULES
Never leave a tool unattended with the air hose
attached.
Never point any air tool toward yourself or others.
Do not operate this air compressor if it does not
contain a legible warning label.
Do not continue to use a tool or hose that leaks air or
does not function properly.
Always disconnect the air supply and power supply
before making adjustments, servicing a product, or when
a product is not in use.
Do not attempt to pull or carry the air compressor by
the hose.
Your tool may require more air consumption than this
air compressor is capable of providing.
Always follow all safety rules recommended by the
manufacturer of your air tool, in addition to all safety
rules for the air compressor. Following this rule will
reduce the risk of serious personal injury.
Never direct a jet of compressed air toward people or
animals. Take care not to blow dust and dirt towards
yourself or others. Following this rule will reduce the risk
of serious injury.
Do not use this air compressor to spray chemicals.
Your lungs can be damaged by inhaling toxic fumes. A
respirator may be necessary in dusty environments or
when spraying paint. Do not carry while painting.
Inspect product cords and hoses periodically and, if
damaged, have repaired at your nearest Authorized
Service Center. Constantly stay aware of cord
location. Following this rule will reduce the risk of electric
shock or fire.
Never use an electrical adaptor with this grounded
plug.
Keep the exterior of the air compressor dry, clean, and
free from oil and grease. Always use a clean cloth when
cleaning. Never use brake fluids, gasoline, petroleum-
based products, or any strong solvents to clean the unit.
Following this rule will reduce the risk of deterioration of
the enclosure plastic.
SERVICE
When servicing a product, use only identical
replacement parts. Follow instructions in the
Maintenance section
of this manual. Use of unauthorized
parts or failure to follow Maintenance instructions may
create a risk of injury.
Service must be performed only by qualified repair
personnel. Service or maintenance performed by
unqualified personnel may result in a risk of injury.
Disconnect power supply, open drain valve to decom-
press tanks and allow water to drain, and allow air
compressor to become cool to the touch before
servicing. Turn pressure regulator knob fully counter-
clockwise after shutting off air compressor.
4 – English
SPECIFIC SAFETY RULES
Check damaged parts. Before further use of the air
compressor or air tool, a guard or other part that is
damaged should be carefully checked to determine
that it will operate properly and perform its intended
function. Check for alignment of moving parts, binding
of moving parts, breakage of parts, mounting, and
any other conditions that may affect its operation. A
guard or other part that is damaged should be properly
repaired or replaced by an authorized service center.
Following this rule will reduce the risk of shock, fire, or
serious injury.
Make sure your extension cord is in good condition.
When using an extension cord, be sure to use one
heavy enough to carry the current your product will
draw. A wire gauge size (A.W.G.) of at least 14 is
recommended for an extension cord 25 feet or less in
length. A cord exceeding 50 feet is not recommended.
If in doubt, use the next heavier gauge. The smaller
the gauge number, the heavier the cord. An undersized
cord will cause a drop in line voltage resulting in loss of
power and overheating.
This equipment incorporates parts, such as snap
switches, receptacles, and the like that tend to pro-
duce arcs or sparks and, therefore, when located in a
garage, it should be in a room or enclosure provided for
the purpose, or should be 18 in. or more above the floor.
Never store a tool with air connected. Storing the tool
with air connected can result in unexpected firing and
possible serious personal injury.
Protect your lungs. Wear a face or dust mask if the
operation is dusty. Following this rule will reduce the risk
of serious personal injury.
If the power supply cord is damaged, it must be replaced
only by the manufacturer or by an authorized service
center to avoid risk.
Save these instructions. Refer to them frequently and use
them to instruct others who may use this product. If you
loan someone this product, loan them these instructions
also.
5 – English
SYMBOLS
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper
interpretation of these symbols will allow you to operate the product better and safer.
Safety Alert Indicates a potential personal injury hazard.
Read Operator’s Manual
To reduce the risk of injury, user must read and understand
operator’s manual before using this product.
Eye Protection
Always wear eye protection with side shields marked to comply
with ANSI Z87.1.
Wet Conditions Alert Do not expose to rain or use in damp locations.
Risk of Bursting
Do not adjust regulator to result in output pressure greater than
marked maximum pressure of attachment. Do not use at pressure
greater than 150 PSI.
Risk of Fire or Explosion
Do not spray flammable liquid in a confined area. Spray area must
be well ventilated. Do not smoke while spraying or spray where
spark or flame is present. Keep compressors as far from the spray-
ing area as possible, at least 20 feet from the spraying area and
all explosive vapors.
Risk of Electrical Shock
Hazardous Voltage: Disconnect from power source before servic-
ing. Compressor must be grounded.
Hot Surface
To reduce the risk of injury or damage, avoid contact with any hot
surface.
Risk to Breathing
Air obtained directly from the air compressor should never be used
to supply air for human consumption.
SYMBOL NAME
DESIGNATION/EXPLANATION
The following signal words and meanings are intended to explain the levels of risk associated with this product.
SYMBOL SIGNAL MEANING
DANGER:
Indicates a hazardous situation, which, if not avoided, will result in death or
serious injury.
WARNING:
Indicates a hazardous situation, which, if not avoided, could result in death or
serious injury.
CAUTION:
Indicates a hazardous situation, that, if not avoided, may result in minor or
moderate injury.
NOTICE:
(Without Safety Alert Symbol) Indicates information considered important, but
not related to a potential injury (e.g. messages relating to property damage).
6 – English
SYMBOLS
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper
interpretation of these symbols will allow you to operate the product better and safer.
V Volts Voltage
A Amperes Current
Hz Hertz Frequency (cycles per second)
Alternating Current Type of current
Class II Construction Double-insulated construction
SYMBOL NAME
DESIGNATION/EXPLANATION
DANGER:
This compressor/pump is not equipped and should not be used to supply breathing quality air. Additional equip-
ment would be necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing
as described in Compressed Gas Association Commodity Specification G 7.1 - 1966, OSHA 29 CFR 1910.134.
Compressed Gas Association, 4221 Walney Road, Fifth Floor, Chantilly, VA 20151-2923, (703) 788-2700,
www.cganet.com. Any such additional equipment has not been examined and no implication of proper use for
breathing air is intended or implied.
If this compressor is altered in any way, existing warranties shall be voided. RIDGID® and One World Technologies,
Inc. disclaim any liabilities whatsoever for any loss, personal injury, or damage.
DISCLAIMER OF WARRANTIES
In the event the compressor is used for the purpose of breathing air application and proper in-line safety and alarm
equipment is not simultaneously used, existing warranties shall be voided, and RIDGID® disclaims any liabilities
whatsoever for any loss, personal injury, or damage.
WARNING:
This product and some dust created by power sanding, sawing, grinding, drilling, and other construction activities
may contain chemicals, including lead, known to the State of California to cause cancer, birth defects, or other
reproductive harm. Wash hands after handling.
Some examples of these chemicals are:
lead from lead-based paints,
crystalline silica from bricks and cement and other masonry products, and
arsenic and chromium from chemically-treated lumber.
Your risk from exposure to these chemicals varies, depending on how often you do this type of work. To reduce
your exposure, work in a well-ventilated area and with approved safety equipment, such as dust masks that are
specially designed to filter out microscopic particles.
CALIFORNIA PROPOSITION 65
7 – English
EXTENSION CORDS
Use only 3-wire extension cords that have 3-prong ground-
ing plugs and 3-pole receptacles that accept the product’s
plug. When using a power tool at a considerable distance
from the power source, use an extension cord heavy enough
to carry the current that the tool will draw. An undersized
extension cord will cause a drop in line voltage, resulting in
a loss of power and causing the motor to overheat. Use the
chart provided below to determine the minimum wire size
required in an extension cord. Only round jacketed cords
listed by Underwriter’s Laboratories (UL) should be used.
**Ampere rating (on product data plate)
0-2.0 2.1-3.4 3.5-5.0 5.1-7.0 7.1-12.0 12.1-16.0
Cord Length Wire Size (A.W.G.)
25' 16 16 16 16 14 14
50' 16 16 16 14 14 12
100' 16 16 14 12 10
**Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American Wire Gauge
When working with the product outdoors, use an extension
cord that is designed for outside use. This is indicated by
the letters “W-A” or “W” on the cord’s jacket.
Before using an extension cord, inspect it for loose or
exposed wires and cut or worn insulation.
WARNING:
Keep the extension cord clear of the working area.
Position the cord so that it will not get caught on
lumber, tools, or other obstructions while you are
working with a power tool. Failure to do so can
result in serious personal injury.
WARNING:
Check extension cords before each use. If
damaged replace immediately. Never use the
product with a damaged cord since touching
the damaged area could cause electrical shock
resulting in serious injury.
ELECTRICAL CONNECTION
This product is powered by a precision-built electric motor.
It should be connected to a power supply that is 120 V, AC
only (normal household current), 60 Hz. Do not operate
this product on direct current (DC). A substantial voltage
drop will cause a loss of power and the motor will overheat.
If the product does not operate when plugged into an outlet,
double check the power supply.
SPEED AND WIRING
The no-load speed of this product is approximately
18,000 rpm. This speed is not constant and decreases
under a load or with lower voltage. For voltage, the wiring
in a shop is as important as the motor’s horsepower rating.
A line intended only for lights cannot properly carry an air
compressor motor. Wire that is heavy enough for a short
distance will be too light for a greater distance. A line that
can support one power tool may not be able to support two
or three tools.
GROUNDING INSTRUCTIONS
See Figure 1, page 15.
This product must be grounded. In the event of a malfunction
or breakdown, grounding provides a path of least resistance
for electric current to reduce the risk of electric shock.
This product is equipped with an electric cord having an
equipment-grounding conductor and a grounding plug. The
plug must be plugged into a matching outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
Do not modify the plug provided. If it will not fit the outlet,
have the proper outlet installed by a qualified electrician.
WARNING:
Improper installation of the grounding plug is liable
to result in a risk of electric shock. When repair or
replacement of the cord is required, do not connect
the grounding wire to either flat blade terminal.
The wire with insulation having an outer surface
that is green with or without yellow stripes is the
grounding wire.
Check with a qualified electrician or service personnel if the
grounding instructions are not completely understood, or if
in doubt as to whether the product is properly grounded.
Repair or replace a damaged or worn cord immediately.
This product is for use on a nominal 120 V circuit and has
a grounding plug similar to the plug illustrated in figure 1,
page 15. Only connect the product to an outlet having the
same configuration as the plug. Do not use an adaptor with
this product.
ELECTRICAL
8 – English
GLOSSARY OF TERMS
Pressure Regulator Knob
Regulates the outgoing pressure from the air outlet to the
tool. It is possible to increase or decrease the pressure at
the outlet by adjusting this control knob.
Pressure Switch
Automatically controls the on/off cycling of the compressor.
It stops the compressor when the cut-off pressure in the tank
is reached and starts the compressor when the air pressure
drops below the cut-in pressure.
PSI (Pounds Per Square Inch)
Measurement of the pressure exerted by the force of the
air. The actual psi is measured by a pressure gauge on the
compressor.
Pump
Produces the compressed air with a reciprocating piston
contained within the cylinder.
Regulator Pressure Gauge
Displays the current line pressure. Line pressure is adjusted
by rotating the pressure regulator knob.
Safety Valve
Prevents air pressure in the air tank from rising over a
predetermined limit.
SCFM (Standard Cubic Feet Per Minute) or CFM (Cubic
Feet Per Minute)
A unit of measure of air delivery.
Tank Pressure Gauge
Indicates the pressure in the air tank.
Air Filter
Porous element contained within a metal or plastic housing
attached to the compressor cylinder head which removes
impurities from the intake air of the compressor.
Air Tank
Cylindrical component which contains the compressed air.
Check Valve
Device that prevents compressed air from flowing back from
the air tank to the compressor pump.
Circuit Breaker
Automatically shuts off the compressor if the temperature of
the electric motor exceeds a predetermined limit.
Cut-In Pressure
The low pressure at which the motor will automatically
restart.
Cut-Off Pressure
The high pressure at which the motor will automatically
shut off.
Electric Motor
Device which provides the rotational force necessary to
operate the compressor pump.
Auto On/Off Switch
Control which turns the air compressor on or off. The
pressure switch will not automatically start and control the
compressor unless the manual Auto On/Off switch is in the
Auto On position.
NPT (National Pipe Thread)
A seal thread tape must be used to provide a leak-free seal
on pipe threaded connections.
9 – English
FEATURES
PRODUCT SPECIFICATIONS
Air Tank Capacity ....................................................4.5 gal.
Air Pressure .................................................... 200 psi max.
Air Delivery ............................................5.1 SCFM @ 90 psi
Tested per ISO1217
Gauges ..........................................................2 in. diameter
Input ..............................120 V, AC only, 60 Hz, 14.5 Amps
Duty Cycle ...............................5 minutes On/5 minutes Off
KNOW YOUR AIR COMPRESSOR
See Figure 2, page 15.
The safe use of this product requires an understanding of the
information on the product and in this operator’s manual as
well as a knowledge of the project you are attempting.Before
use of this product, familiarize yourself with all operating
features and safety rules.
CARRYING HANDLE
The air compressor has a carrying handle for easy transport.
DRAIN VALVES
The drain valves, located on the bottom of the tanks, are
for draining condensation to help prevent tank corrosion.
INTERNAL OVERLOAD SWITCH
The air compressor will shut off during an electrical overload.
To reset the internal overload switch, unplug the air compres-
sor and allow the unit to cool.
PRESSURE REGULATOR KNOB
Use the pressure regulator knob to adjust the amount of air
being delivered through the hose. Push the knob in to lock
the desired pressure setting. To unlock the knob and adjust
the pressure, pull the knob out. This prevents movement of
the knob caused by vibration during use.
REGULATOR PRESSURE GAUGE
The current line pressure is displayed on the regulator
pressure gauge. This pressure can be adjusted by rotating
the pressure regulator knob.
SAFETY VALVE
The safety valve is designed to automatically release air if
the air tank pressure exceeds the preset maximum.
TANK PRESSURE GAUGE
The tank pressure gauge indicates the pressure of the air
in the tank.
ASSEMBLY
WARNING:
Do not use this product if it is not completely
assembled or if any parts appear to be missing or
damaged. Use of a product that is not properly and
completely assembled or with damaged or missing
parts could result in serious personal injury.
WARNING:
Do not attempt to modify this product or create
accessories or attachments not recommended
for use with this product. Any such alteration
or modification is misuse and could result in a
hazardous condition leading to possible serious
personal injury.
If any parts are damaged or missing, please call 1-866-539-1710 for assistance.
10 – English
OPERATION
DANGER:
Do not disassemble check valve, tank drain valves
or safety relief valve with air in tank — bleed
tanks. Failure to depressurize tank could result in
explosion and/or serious personal injury.
WARNING:
Do not allow familiarity with products to make you
careless. Remember that a careless fraction of a
second is sufficient to inflict severe injury.
WARNING:
Always wear eye protection with side shields
marked to comply with ANSI Z87.1. Failure to do
so could result in objects being thrown into your
eyes resulting in possible serious injury.
WARNING:
Do not use any attachments or accessories not
recommended by the manufacturer of this product.
The use of attachments or accessories not
recommended can result in serious personal injury.
WARNING:
This equipment incorporates parts, such as snap
switches, receptacles, and the like that tend to
produce arcs or sparks and, therefore, when
located in a garage, it should be in a room or
enclosure provided for the purpose, or should be
18 in. or more above the floor.
WARNING:
Do not attach any tools to the open end of the hose
until start-up has been completed.
NOTICE:
Do not use in an environment that is dusty or
otherwise contaminated. Using the air compressor
in this type of environment may cause damage to
the unit.
NOTICE:
The wiring to a receptacle and the length of any
extension cords being used play an important role
in the operation of this product. Wiring intended
for lights cannot properly carry an air compressor
motor, and wire that is heavy enough for a short
distance may be insufficient for a greater distance.
Before using this product, verify your receptacle
is wired appropriately for air compressor use and
the length and gauge of any extension cord used is
sufficient to carry the current of the air compressor.
APPLICATIONS
Air compressors are utilized in a variety of air system
applications. Match hoses, connectors, air tools, and
accessories to the capabilities of the air compressor.
You may use this product for the purposes listed below:
Operating some air-powered tools
Operating air accessories such as air nozzles and
automotive tire inflators
CONNECTING/DISCONNECTING AIR HOSE
(HOSE NOT PROVIDED)
See Figure 3, page 16.
WARNING:
Never exceed the air tool’s pressure rating as
recommended by the manufacturer. When using
this air compressor as an inflation device, always
follow the maximum inflation guidelines stated by
the manufacturer of the item being inflated.
Make sure the air compressor is turned off and unplugged.
Rotate pressure regulator knob fully in the counter-
clockwise direction so that the outlet pressure is at
zero (0) psi.
Attach hose with quick connect air fitting to 1/4 in. quick
coupler on air compressor. Make sure to push the hose
adapter end fully into the coupler until the sleeve springs
forward to lock it in place.
To disconnect an air hose or an air tool:
Confirm that the outlet pressure is at zero (0) psi.
When disconnecting a hose from 1/4-in. quick coupler,
always firmly hold release end of hose.
Pull back on the release sleeve on the 1/4-in. quick
coupler.
With a firm grip, pull out the quick-connect air fitting that
is attached to the quick coupler.
BREAK-IN PERIOD
Before first use, run the air compressor at zero tank pressure
with the drain valves fully open for 30 minutes.
11 – English
Attach 1/4 in. NPT quick-connect air fitting to accessory
or tool you intend to use.
Insert the other end of the quick-connect air fitting to the
quick coupler on the open end of hose.
Connect the power cord to the power supply.
Move the Auto On/Off switch to the Auto On position.
Set the amount of air pressure desired using the pressure
regulator knob. Pull the knob out, then turn clockwise to
increase or counterclockwise to decrease the air pressure
through the hose. When the desired pressure is set, push
the knob back in to lock.
NOTE: Always use the minimum amount of pressure
necessary for your application. Using a higher pressure
than needed will drain air from the tank more rapidly and
cause the unit to cycle on more frequently.
Following all safety precautions in this manual and the
manufacturer’s instructions in the air tool manual, you
may now proceed to use your air-powered tool.
NOTE: The air compressor will shut off during an electri-
cal overload. To reset the internal overload switch, unplug
the air compressor and allow the unit to cool.
When finished, always drain the tank and unplug the
unit. Never leave the unit plugged in and/or running
unattended.
DRAINING THE TANKS
See Figures 7 - 8, page 16.
To help prevent tank corrosion and keep moisture out of the
air used, the air tanks of the compressor should be drained
daily.
To drain:
Turn the air compressor off and disconnect the plug from
the power supply.
Pull the ring on the pressure relief valve to release air until
tank pressure gauge reads less than 20 psi.
Release the ring.
Turn the drain valves 90° counterclockwise to the ON
(open) position.
Tilt tanks to drain moisture from tanks into a suitable
container.
NOTE: Condensate is a polluting material and should be
disposed of in compliance with local regulations.
If a drain valve is clogged, release all air pressure, remove
and clean valve, then reinstall.
WARNING:
Unplug the air compressor and release all air from
the tanks before servicing. Failure to depressurize
tanks before attempting to remove valve could
cause serious personal injury.
OPERATION
TURNING THE AIR COMPRESSOR ON/OFF
See Figure 4, page 16.
With the air compressor plugged in, move the Auto On/Off
switch to the Auto On position to power the compressor
on.
To turn the air compressor off, move the Auto On/Off
switch to the OFF position.
NOTE: When the compressor is in the Auto On position,
the air compressor will automatically turn back on when
the designated tank air pressure drops below the preset
pressure limit. It will also shut off again when the cut-off
pressure is reached.
WARNING:
Never exceed the air tool’s pressure rating as
recommended by the manufacturer. When using
this air compressor as an inflation device, always
follow the maximum inflation guidelines stated by
the manufacturer of the item being inflated.
WARNING:
Always ensure the switch is in the OFF position
and the regulator pressure gauge reads zero
before changing air tools or disconnecting the hose
from the air outlet. Failure to do so could result in
possible serious personal injury.
USING THE AIR COMPRESSOR
See Figures 5 - 6, page 16.
WARNING:
Risk of bursting. Do not adjust pressure regulator
knob to result in output pressure greater than
marked maximum pressure of attachment and/
or the item being inflated. Never use at pressure
greater than 150 psi. Failure to heed this warning
could result in possible serious personal injury.
WARNING:
Air powered tools may require more air consumption
than this air compressor is capable of providing.
Check the tool manual to avoid damage to the tool
or risk of personal injury.
Ensure Auto On/Off lever is in the OFF position and air
compressor is unplugged.
Attach air hose following the instructions in Connecting/
Disconnecting Air Hose (hose not provided).
12 – English
OPERATION
Turn the drain valves 90° clockwise to the OFF (closed)
position.
WARNING:
RISK OF BURSTING. All compressed air
tanks have a limited lifespan. The lifespan can
be affected by a number of factors, including
operating conditions of the air compressor, proper
maintenance of the tank, and unauthorized repairs
and modifications. Since deterioration of the tank
can occur internally with no outward signs, the
air tank(s) on this compressor MUST be removed
from service by the end of the year shown on the
data label. Use of the air compressor after this
date increases the risk of an air tank rupture, which
could result in serious personal injury.
CHECKING THE SAFETY VALVE
See Figure 8, page 16.
DANGER:
Do not attempt to tamper with the safety valve.
Anything loosened from this device could fly up
and hit you. Failure to heed this warning could
result in death or serious personal injury.
The safety valve will automatically release air if the air tank
pressure exceeds the cut-out pressure. The valve should be
checked before each day of use by pulling the ring by hand.
Turn the air compressor on and allow the tanks to fill. The
compressor will shut off when the pressure reaches the
cut-out pressure.
Turn the air compressor off.
Pull the ring on the safety valve to release air for three to
five seconds to allow pressurized air to escape. Release
the ring. The safety release valve must reset and hold
pressure before all compressed air is exhausted from the
tank/pressure vessel.
Any continued loss of air after performing the above steps
indicates a problem with the safety valve. Discontinue
use and seek service before continued use of the air
compressor.
WARNING:
If air leaks after the ring has been released or if
the valve is stuck and cannot be actuated by the
ring, do not use the air compressor until the safety
valve has been replaced. Use of the air compressor
in this condition could result in serious personal
injury.
13 – English
MAINTENANCE
WARNING:
Always release all pressure, disconnect from power
supply, and allow unit to cool to the touch before
cleaning or making repairs on the air compressor.
WARNING:
Always wear eye protection with side shields
marked to comply with ANSI Z87.1. Failure to do
so could result in objects being thrown into your
eyes resulting in possible serious injury.
WARNING:
When servicing, use only identical replacement
parts. Use of any other parts could create a hazard
or cause product damage.
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
WARNING:
Do not at any time let brake fluids, gasoline,
petroleum-based products, penetrating oils, etc.,
come in contact with plastic parts. Chemicals can
damage, weaken or destroy plastIc which could
result in serious personal injury.
LUBRICATION
All of the bearings in this product are lubricated with a suf-
ficient amount of high grade lubricant for the life of the unit
under normal operating conditions. Therefore, no further
lubrication is required.
POWER SUPPLY CORD REPLACEMENT
If replacement of the power supply cord is necessary, this
must be done by an authorized service center in order to
avoid a safety hazard.
REPLACING THE AIR FILTER
See Figure 9, page 16.
Press and rotate the air filter cover counterclockwise to
remove the air filter and air filter housing.
Grasp the tabs on the air filter cover and pull away from
the housing.
Remove the old air filter.
Install the new air filter.
Replace the air filter cover by lining up the tabs and push-
ing it onto the housing until it clicks in place.
Replace the air filter housing into the compressor by
turning it clockwise. Tighten until snug.
STORING THE AIR COMPRESSOR
See Figure 10, page 16.
Unplug the air compressor.
Disconnect air hose and air tool from the product.
Drain air tanks according to instructions.
Thoroughly clean air compressor and any accessories.
Coil power cord around handle and motor as shown.
Secure in place using the cord clip.
14 – English
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
Compressor will not run Loss of power or overheating
No electrical power
Blown shop/house fuse
Shop/house breaker open
Pressure switch bad
Tank is full of air
Internal overload switch is tripped
Check for proper use of extension cord
Check to be sure unit is plugged in; Check
fuse/breaker
Replace shop/house blown fuse
Reset shop/house breaker, determining why
problem happened
Take compressor to service center
Compressor will turn on when tank pressure
drops to cut-in pressure
Unplug compressor and allow unit to cool
Motor hums but cannot run
or runs slowly
Low voltage
Wrong gauge wire or length of extension cord
Shorted or open motor winding
Defective check valve or unloader
Use compressor on outlet with sufficient voltage
Check for proper gauge wire and cord length
Take compressor to service center
Take compressor to service center
Internal overload switch trips
repeatedly
Low voltage
Lack of proper ventilation/room temperature
too high
Wrong gauge wire or length of extension cord
Use compressor on outlet with sufficient voltage
Move compressor to well-ventilated area
Check for proper gauge wire and cord length
Air tank pressure drops when
compressor shuts off
Loose connections (fittings, tubing, etc.)
Loose drain valve / open drain valve
Check valve leaking
Check all connections with soap and water solu-
tion and tighten
Tighten drain valve / close drain valve
Take compressor to service center
DANGER:
Do not disassemble check valve, tank
drain valves or safety relief valve with air
in tank — bleed tanks.
Excessive moisture in dis-
charge air
Excessive water in air tanks
High humidity
Drain tanks
Move to area of less humidity; use air line filter
Compressor runs continu-
ously
Defective pressure switch
Excessive air usage
Piston rings are worn
Take compressor to service center
Decrease air usage; compressor not large
enough for tool’s requirement
Replace piston rings; Call customer service for
assistance
Air output lower than normal Broken inlet valves
Connections leaking
Take compressor to service center
Tighten connections
NOTE: ILLUSTRATIONS START ON PAGE 15 AFTER FRENCH
AND SPANISH LANGUAGE SECTIONS.
This product has a 90-Day Satisfaction Guarantee Policy,
as well as a Three-year Limited Warranty. For Warranty and Policy details,
please go to www.RIDGID.com or call (toll free) 1-866-539-1710.
2 – Français
RÈGLES DE SÉCURITÉ GÉNÉRALES
AVERTISSEMENT :
Lire et veiller à bien comprendre toutes les
instructions. Le non-respect de toutes les
instructions ci-dessous peut entraîner un choc
électrique, un incendie et/ou des blessures graves.
CONSERVER CES INSTRUCTIONS
LIEU DE TRAVAIL
Garder le lieu de travail propre et bien éclairé. Les
établis encombrés et les endroits sombres sont propices
aux accidents. Le sol ne doit pas être rendu glissant par
de la cire ou de la sciure.
Ne pas utiliser d’outils électriques dans des
atmosphères explosives, par exemple en présence
de liquides, gaz ou poussières inflammables. Les
outils électriques produisent des étincelles risquant
d’enflammer les poussières ou vapeurs.
Garder les badauds, enfants et visiteurs à l’écart
pendant l’utilisation d’outils. Les distractions peuvent
causer une perte de contrôle.
Utiliser le compresseur d’air dans un endroit dégagé,
à au moins 460 mm (18 po) de toute paroi ou objet
risquant de gêner l’entrée de l’air dans les ouvertures
de ventilation.
SÉCURITÉ ÉLECTRIQUE
Éviter tout contact du corps avec des surfaces mises
à la terre, telles que tuyaux, radiateurs, cuisinières
et réfrigérateurs. Le risque d’électrocution est accru
lorsque le corps est mis à la terre.
Ne pas exposer les outils électriques à la pluie ou
l’humidité. La pénétration d’eau dans ces outils accroît
le risque de choc électrique.
Ne pas maltraiter le cordon d’alimentation. Ne jamais
utiliser le cordon d’alimentation pour transporter
l’outil et ne jamais débrancher ce dernier en tirant sur
le cordon. Garder le cordon à l’écart de la chaleur,
de l’huile, des objets tranchants et des pièces en
mouvement. Remplacer immédiatement tout cordon
endommagé. Un cordon endommagé accroît le risque
d’électrocution.
Pour les travaux à l’extérieur, utiliser un cordon
spécialement conçu à cet effet, marqué « W-A » ou
« W ». Ces cordons sont spécifiques à l’emploi en plein-
air et réduisent les risques d’électrocution.
SÉCURITÉ PERSONNELLE
Lors du chargement, de l’utilisation ou de l’entretien
de cet outil, l’opérateur et les personnes se trouvant
sur le lieu de travail doivent TOUJOURS porter
un dispositif oculaire à protection FRONTALE et
LATÉRALE, conforme aux normes ANSI. Une telle
protection est requise, car les clous / agrafes et débris
projetés peuvent causer des lésions oculaires graves.
Il incombe à l’employeur et/ou l’utilisateur de veiller
à ce qu’une protection oculaire adéquate soit
utilisée. Nous recommandons d’utiliser un masque
facial à champ de vision se portant par-dessus des
lunettes de vue ou de sécurité et potégeant des débris
projetés sur le devant et les côtés. Toujours porter
une protection oculaire certifiée conforme à la norme
ANSI Z87.1.
Des équipements de protection supplémentaires sont
requis dans certains environnements. Par exemple, le
lieu de travail peut présenter un niveau de bruit susceptible
d’entraîner des lésions auditives. Il incombe à l’opérateur et à
l’utilisateur qu’une protection audidive soit fournie et utilisée
par l’opérateur et les autres personnes se trouvant sur le
lieu de travail. Certains environnements requièrent le port
d’un casque. Il incombe à l’employeur et/ou l’utilisateur de
veiller à ce qu’un casque conforme à la norme ANSI Z89.1
soit utilisé.
Rester attentif, prêter attention au travail et faire
preuve de bon sens lors de l’utilisation de tout
outil électrique. Ne pas utiliser cet outil en état de
fatigue ou sous l’influence d’alcool, de drogues ou
de médicaments. Un moment d’inattention pendant
l’utilisation d’un outil électrique peut entraîner des
blessures graves.
Porter une tenue appropriée. Ne porter ni vêtements
amples, ni bijoux. Attacher ou couvrir les cheveux
longs. Garder les cheveux, les vêtements et les gants
à l’écart des pièces en mouvement. Les vêtements
amples, bijoux et cheveux longs peuvent se prendre dans
les pièces en mouvement.
Ne pas travailler hors de portée. Toujours se tenir
bien campé et en équilibre. Une bonne tenue et un bon
équilibre permettent de mieux contrôler l’outil en cas de
situation imprévue.
Utiliser l’équipement de sécurité. Toujours porter une
protection oculaire. Suivant les conditions, le port d’un
masque antipoussière, de chaussures de sécurité, d’un
casque ou d’une protection auditive est recommandé.
Ne pas utiliser l’outil sur une échelle ou un support
instable. Une bonne tenue et un bon équilibre permettent
de mieux contrôler l’outil en cas de situation imprévue.
UTILISATION ET ENTRETIEN DE L’OUTIL
Ne pas dépasser les pressions nominales des
composants du système.
Protéger les flexibles d’alimentation et d’outil contre les
dommages et risques de perforation. Garder le flexible et
le cordon d’alimentation électrique à l’écart de la chaleur,
de l’huile, des solvants et sols humides ou mouillés.
Avant chaque utilisation, s’assurer que les fexibles
ne sont pas affaiblis ou endommagés et vérifier tous
les branchements. Ne pas utiliser le compresseur si les
flexibles ne sont pas en bon état. Acheter de nouveaux
flexibles ou contacter un centre de réparations agréé,
pour les faire inspecter ou réparer.
3 – Français
RÈGLES DE SÉCURITÉ GÉNÉRALES
Apprendre à connaître le compresseur d’air . Lire
attentivement le manuel d’utilisation. Apprendre les
applications et les limites de l’outil, ainsi que les risques
spécifiques relatifs à son utilisation. Le respect de cette
règle réduira les risques d’incendie, de choc électrique
et de blessures.
Purger le réservoir après chaque journée de travail.
Si le compresseur ne doit pas être utilisé pendant un
certain temps, il est préférable de laisser le robinet de
purge ouvert. Cela permettra d’évacuer complètement
l’humidité et aidera à empêcher la corrosion de l’intérieur
du réservoir.
Risque d’incendie ou d’explosion. Ne pas vaporiser de
liquides inflammables dans un endroit confiné. La zone de
pulvérisation doit être bien ventilée. Ne pas fumer pendant
la pulvérisation ou pulvériser en présence de flammes.
Garder les compresseurs le plus loin possible des zones
de pulvérisation, au moins à 6,1 m (20 pi) de la zone de
pulvérisation et de toutes vapeurs explosives.
Risque d’éclatement. Ne pas régler le détendeur pour
obtenir une pression de sortie supérieure à la pression
nominale de l’accessoire utilisé. Ne pas utiliser une
pression de plus de 150 psi.
Si connecter à un circuit protéger par des fusibles,
utiliser des fusibles coussinets avec ce produit.
Pour réduire le risque de choc électrique, ne pas
exposer à la pluie. Remiser à l’intérieur.
Une fois l’an, s’assurer que le réservoir n’est pas rouillé
ou piqué et ne présente aucun défaut risquant de le
rendre dangereux. Ne jamais percer ou souder le réservoir.
S’assurer que le flexible n’est ni bloqué, ni accroché.
Un flexible emmêlé ou entortillé peut causer une perte
d’équilibre et être endommagé.
Le compresseur ne doit être utilisé que pour les
applications pour lesquelles il est conçu. Ne pas
altérer ou modifier le compresseur ou l’utiliser pour
des applications pour lesquelles il n’est pas conçu.
Ne jamais oublier qu’un usage incorrect ou abusif
de cet outil peut mettre l’opérateur et les autres
personnes présentes en danger.
Ne jamais laisser l’outil sans surveillance avec le
flexible d’air branché.
Ne pas pointer un outil pneumatique quel qu’il soit
vers soi ou d’autres personnes.
Ne pas utiliser ce compresseur s’il ne comporte pas
d’autocollant d’avertissement.
Ne pas utiliser un outil qui présente des fuites d’air
ou ne fonctionne pas correctement.
Toujours débrancher l’outil des alimentations
pneumatique et électrique avant d’effectuer des
réglages ou entretiens et lorsque l’outil n’est pas utilisé.
Ne pas essayer de tirer ou de transporter le
compresseur par son flexible.
La consommation d’air de l’outil peut être supérieure
à la capacité de ce compresseur.
Toujours respecter les consignes de sécurité du fabricant
de l’outil pneumatique, ainsi que toutes les règles de
sécurité d’utilisation du compresseur. Le respect de cette
consigne réduira les risques de blessures graves.
RÈGLES DE SÉCURITÉ PARTICULIÈRES
Relâcher toutes les pressions du système lentement.
La projection de poussières et de débris peut être
dangereuse.
Ranger les outils non utilisés hors de portée des
enfants et des personnes n’ayant pas reçu des
instructions adéquates. Dans les mains de personnes
n’ayant pas reçu des instructions adéquates, les outils
sont dangereux.
Entretenir soigneusement les outils. Respecter toutes
les instructions d’entretien. Les outils correctement
entretenus sont plus faciles à contrôler.
Vérifier qu’aucune pièce mobile n’est mal alignée,
grippée ou brisée et s’assurer qu’aucun autre
problème risque d’affecter le bon fonctionnement
de l’outil. En cas de dommages, faire réparer l’outil
avant de l’utiliser de nouveau. Beaucoup d’accidents
sont causés par des outils mal entretenus.
Garder l’extérieur du compresseur sec, propre et
exempt d’huile ou de graisse. Toujours utiliser un chiffon
propre pour le nettoyage. Ne jamais utiliser de liquide de
freins, d’essence, de produits à base de pétrole ou de
solvants puissants pour nettoyer l’outil. Le respect de
cette règle réduira les risques de perte du contrôle et
d’endommagement du boîtier en plastique.
DÉPANNAGE
Utiliser exclusivement des pièces identiques à celles
d’origine pour les réparations. Se conformer aux
instructions de la section Entretien de ce manuel.
L’usage de pièces non autorisées ou le non respect des
instructions d’entretien peut présenter des risques de
blessures.
Le dépannage des outils doit être confié exclusivement
à un personnel qualifié. Les réparations ou entretiens
effectués par des personnes non qualifiées présentent
des risques de blessures.
Débrancher le compresseur, ouvrir le robinet de purge
pour relâcher la pression, laisser l’eau s’écouler et
laisser la machine refroidir avant de procéder à tout
entretien. Après avoir arrêté le compresseur, tourner
le bouton du détendeur à fond vers la gauche.
4 – Français
RÈGLES DE SÉCURITÉ PARTICULIÈRES
Ne jamais diriger le jet d’air comprimé vers des
personnes ou animaux. Veiller à ne pas projeter de la
poussière ou de la saleté vers soi-même ou d’autres
personnes. Le respect de cette règle réduira les risques
de blessures graves.
Ne pas utiliser ce compresseur pour la pulvérisation
de produits chimiques. L’inhalation de vapeurs toxiques
peut causer des lésions pulmonaires. Le port d’un
respirateur peut être nécessaire dans les environnements
poussiéreux ou lors de la pulvérisation de peinture. Ne
pas porter lorsque vous êtes en train de peindre.
Inspecter régulièrement le cordon d’alimentation de
l’outil et les flexibles. S’ils sont endommagés, les
confier au centre de réparations agréé le plus proche.
Toujours être conscient de l’emplacement du cordon.
Le respect de cette consigne réduira les risques de choc
électrique et d’incendie.
Ne jamais utiliser un adaptateur électrique avec cette
prise de terre.
Vérifier l’état des pièces. Avant d’utiliser le
compresseur de nouveau, examiner soigneusement
les pièces et dispositifs de protection qui semblent
endommagés afin de déterminer s’ils fonctionnent
correctement et remplissent les fonctions prévues.
Vérifier l’alignement des pièces mobiles, s’assurer
qu’aucune pièce n’est bloquée ou cassée, vérifier la
fixation de chaque pièce et s’assurer qu’aucun autre
problème ne risque d’affecter le bon fonctionnement
de l’outil. Toute protection ou pièce endommagée
doit être correctement réparée ou remplacée
dans un centre de réparations agréé. Le respect de
cette consigne réduira les risques de choc électrique,
d’incendie et de blessures graves.
S’assurer que le cordon prolongateur est en bon
état. Si un cordon prolongateur est utilisé, s’assurer
que sa capacité est suffisante pour supporter le
courant de fonctionnement de l’outil. Un calibre de
fil (A.W.G) d’au minimum 14 est recommandé pour un
cordon prolongateur de 8 mètres (25 pi) maximum.
L’usage d’un cordon de plus de 15 mètres (50 pi) est
déconseillé. En cas de doute, utiliser un cordon du
calibre immédiatement supérieur. Moins le numéro
de calibre est élevé, plus la capacité du fil est grande.
Un cordon de capacité insuffisante causerait une baisse
de la tension de ligne, entraînant une perte de puissance
et une surchauffe.
Un cet équipement incorpore des parties,
commutateurs telles que de claquement, les prises,
et l’aimé qu’avoir tendance à produire des arcs ou des
étincelles et, donc, quand localisé dans un garage, ce doit
être dans une pièce ou la clôture a pourvu au but, ou doit
être 457 mm (18 po) ou plus au-dessus du plancher.
Ne jamais emmagasiner l’outil avec l’air connecté.
Emmagasiner l’outil avec l’air connecté peut avoir pour
résultat vider imprévu et la blessure personnelle, sérieuse
et possible.
Protection respiratoire. Porter un masque facial ou
respiratoire si le travail produit de la poussière. Le respect
de cette règle réduira les risques de blessures graves.
Si le cordon d’alimentation est endommagé, il doit être
remplacé uniquement pas le fabricant ou par un centre
de réparation agréé pour éviter tout risque.
Conserver ces instructions. Les consulter fréquemment
et les utiliser pour instruire les autres utilisateurs éventuels.
Si cet outil est prêté, il doit être accompagné de ces
instructions.
5 – Français
SYMBOLES
Certains des symboles ci-dessous peuvent être utilisés sur produit. Veiller à les étudier et à apprendre leur signification.
Une interprétation correcte de ces symboles permettra d’utiliser produit plus efficacement et de réduire les risques.
Symbole d’alerte de sécurité Indique un risque de blessure potentiel.
Lire manuel d’utilisation
Pour réduire les risques de blessures, l’utilisateur doit lire et veiller à
bien comprendre le manuel d’utilisation avant d’utiliser ce produit.
Protection oculaire
Toujours porter une protection oculaire avec écrans latéraux
certifiée conforme à la norme ANSI Z87.1.
Avertissement concernant
l’humidité
Ne pas exposer à la pluie ou l’humidité.
Risque d’éclatement
Ne pas régler le détendeur pour obtenir une pression de sortie
supérieure à la pression nominale de l’accessoire utilisé. Ne pas
utiliser une pression de plus de 1034 kPa (150 PSI).
Risque d’incendie ou
d’explosion
Ne pas vaporiser de liquides inflammables dans un endroit confiné.
La zone de pulvérisation doit être bien ventilée. Ne pas fumer pen-
dant la pulvérisation ou pulvériser en présence de flammes.Garder
les compresseurs le plus loin possible des zones de pulvérisation,
au moins à 6,1 m (20 pi) de la zone de pulvérisation et de toutes
vapeurs explosives.
Risque de choc électrique
Tension dangereuse : Débrancher de la prise secteur avant de
faire des réparations. Le compresseur doit être mis à la terre.
Surface brûlante
Pour éviter les risques de blessures ou de dommages, éviter
tout contact avec les surfaces brûlantes.
Risques d’inhalation
L’air sortant directement du compresseur ne doit jamais être utilisé
pour la respiration.
SYMBOLE NOM
DÉSIGNATION / EXPLANATION
Les termes de mise en garde suivants et leur signification ont pour but d’expliquer le degré de risques associé à l’utilisation
de ce produit.
SYMBOLE SIGNAL SIGNIFICATION
DANGER :
Indique une situation dangereuse qui, si elle n’est pas évitée, aura pour
conséquences des blessures graves ou mortelles.
AVERTISSEMENT :
Indique une situation dangereuse qui, si elle n’est pas évitée, pourrait entraîner
des blessures graves ou mortelles.
ATTENTION :
Indique une situation dangereuse qui, si elle n’est pas évitée, pourraît entraîner
des blessures légères ou de gravité modérée.
AVIS :
(Sans symbole d’alerte de sécurité) Indique les informations jugées importantes
sans toutefois représenter un risque de blessure (ex. : messages concernant les
dommages matériels).
6 – Français
SYMBOLES
Certains des symboles ci-dessous peuvent être utilisés sur produit. Veiller à les étudier et à apprendre leur signification.
Une interprétation correcte de ces symboles permettra d’utiliser produit plus efficacement et de réduire les risques.
V Volts Tension
A Ampères Intensité
Hz Hertz Fréquence (cycles par seconde)
Courant alternatif Type de courant
Construction de classe II Construction à double isolation
SYMBOL NAME
DESIGNATION/EXPLANATION
DANGER :
Ce compresseur / pompe n’est pas équipé et ne doit pas être utiliser pour fournir de l’air de qualité respirable. Un
équipement supplémentaire est nécessaire pour filtrer et purifier l’air conformément aux spécifications minimum
d’air respirable de qualité D G 7.1 - 1966, OSHA 29 CFR 1910. 134 de la Compressed Gas Association, 4221
Walney Road, Fifth Floor, Chantilly, VA 20151-2923, (703) 788-2700, www.cganet.com. Un tel équipement n’a pas
été examiné et nulle implacation d’utilisation propre pour l’air respirable n’est prévue ou implicite.
Si ce compresseur est modifier de quelle que manière que ce soit, les garanties en vigueur seront déclarées
nulles et non avenues. RIDGID®. et One World Technologies, Inc., déclineront toute responsabilité pour les pertes,
blessures et dommages résultant de son utilisation.
EXONÉRATION DE GARANTIES
Si ce compresseur est utilisé pour des applications d’air respirable sans un système de sécurité et d’alarme
approprié, les garanties en vigueur seront déclarées nulles et non avenues et RIDGID®. déclinera toute
responsabilité pour les pertes, blessures et dommages résultant de son utilisation.
AVERTISSEMENT :
Ce produit et la poussière dégagée lors du ponçage, sciage, meulage, perçage de certains matériaux et lors
d’autres opérations de construction contient des produits chimiques reconnus causer le cancer, des malforma-
tions congénitales ou des lésions de l’appareil reproducteur. Bien se laver les mains après toute manipulation.
Voici certains exemples de ces produits chimiques :
le plomb contenu dans la peinture au plomb,
la silice cristalline contenue dans les briques, le béton et d’autres produits de maçonnerie, ainsi que
l’arsenic et le chrome contenus dans le bois de construction traité par produits chimiques.
Le risque présenté par l’exposition à ces produits varie en fonction de la fréquence de ce type de travail. Pour
réduire l’exposition,: travailler dans un endroit bien aéré et utiliser des équipements de sécurité approuvés tels
que masques antipoussière spécialement conçus pour filtrer les particules microscopiques.
PROPOSITION 65 DE L'ÉTAT DE CALIFORNIE
7 – Français
CONNEXION ÉLECTRIQUE
Ce compresseur est équipé d’un moteur électrique
de précision. Il doit être branché uniquement sur une
alimentation 120 V, c.a. (courant résidentiel standard),
60 Hz. Ne pas utiliser cet outil sur une source de courant
continu (c.c.). Une chute de tension importante causerait
une perte de puissance et une surchauffe du moteur. Si le
compresseur ne fonctionne pas une fois branché, vérifier
l’alimentation électrique.
VITESSE ET CÂBLAGE
La vitesse à vide de ce compresseur est d’environ 18 000 r/ min.
La vitesse n’est pas constante et elle diminue sous une
charge ou en présence d’une baisse de tension. Le câblage
de l’atelier est aussi important que la puissance nominale du
moteur. Une ligne conçue seulement pour l’éclairage ne peut
pas alimenter correctement le moteur d’un outil électrique.
Un fil électrique d’une capacité suffisante pour une courte
distance ne le sera pas nécessairement pour une distance
plus longue. Une ligne dont la capacité est suffisante pour
un outil électrique ne l’est pas nécessairement pour deux
ou trois.
INSTRUCTIONS DE MISE À LA TERRE
Voir la figure 1, page 16.
En cas de problème de fonctionnement ou de panne, la
mise à la terre fournit un chemin de résistance au courant
électrique, pour réduire le risque de choc électrique. Ce
compresseur est équipé d’un cordon électrique avec
conducteur et fiche de mise à la terre. Le cordon doit être
branché sur une prise correctement installée et mise à la
terre conformément à tous les codes et réglementations
locaux en vigueur.
Ne pas modifier la fiche fournie. Si elle ne peut pas être
insérée dans la prise secteur, faire installer une prise
adéquate par un électricien qualifié.
AVERTISSEMENT :
L’usage d’un cordon prolongateur incorrect peut
présenter des risques de choc électrique. Si
le cordon doit être réparé ou remplacé, ne pas
connecter le fil de terre de l’outil sur une borne
sous tension.Le fil à gaine verte, avec ou sans
traceur jaune est le fil de terre.
Consulter un électricien qualifié ou le personnel de service si
les instructions de mise à la terre ne sont pas bien comprises,
ou en cas de doute au sujet de la mise à la terre.
Tout cordon endommagé doit être réparé ou remplacé
immédiatement.
Ce compresseur est conçu pour être branché sur un circuit
comportant une prise telle que celle montrée à la figure 2,
page 16. Sa fiche est dotée d’une broche de terre semblable
à celle représentée. Ce produit peut être mis à la terre.
CARACTÉRISTIQUES ÉLECTRIQUES
CORDONS PROLONGATEURS
Utiliser exclusivement des cordons prolongateurs à 3
fils dotés d’une fiche à prise de terre branchés sur une
prise triphasée compatible avec la fiche de l’outil. Lors
de l’utilisation du compresseur à grande distance d’une
prise secteur, veiller à utiliser un cordon prolongateur d’une
capacité suffisante pour supporter l’appel de courant de
l’outil. Un cordon de capacité insuffisante causerait une
baisse de la tension de ligne, entraînant une perte de
puissance et une surchauffe. Se reporter au tableau ci-
dessous pour déterminer le calibre minimum de fil requis
pour un cordon donné. Utiliser exclusivement des cordons à
gaine cylindrique homologués par Underwriter’s Laboratories
(UL).
**Intensité nominale (sur la plaquette signalétique du compresseur)
0-2.0 2.1-3.4 3.5-5.0 5.1-7.0 7.1-12.0 12.1-16.0
Longueur Calibre de fil
du cordon (A.W.G.)
25' 16 16 16 16 14 14
50' 16 16 16 14 14 12
100' 16 16 14 12 10
**Utilisé sur circuit de calibre 12 – 20 A
NOTE : AWG = American Wire Gauge
Pour les travaux à l’extérieur, utiliser un cordon prolongateur
spécialement conçu à cet effet. La gaine des cordons de ce
type porte l’inscription « W-A » ou « W ».
Avant d’utiliser un cordon prolongateur, vérifier que ses fils
ne sont ni détachés ni exposés et que son isolation n’est ni
coupée, ni usée.
AVERTISSEMENT :
Maintenir le cordon prolongateur à l’écart de la
zone de travail. Lors du travail avec un cordon
électrique, placer le cordon de manière à ce qu’il ne
risque pas de se prendre dans les pièces de bois,
outils et autres obstacles. Ne pas prendre cette
précaution peut entraîner des blessures graves.
AVERTISSEMENT :
Vérifier l’état des cordons prolongateurs avant
chaque utilisation. Remplacer immédiatement
tout cordon endommagé. Ne jamais utiliser un
compresseur dont le cordon d’alimentation est
endommagé, car tout contact avec la partie
endommagée pourrait causer un choc électrique
et des blessures graves.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

RIDGID OF45200SS-R175RNF-R5025LF Manuel utilisateur

Catégorie
Compresseurs d'air
Taper
Manuel utilisateur