Dimplex XLF60 Le manuel du propriétaire

Catégorie
Chauffe-eau
Taper
Le manuel du propriétaire

Ce manuel convient également à

Owners Manual
Model
XLF50
XLF60
XLF74
XLF100
7215520100R02
IMPORTANT SAFETY INFORMATION: Always read this manual rst
before attempting to install or use this replace. For your safety, always
comply with all warnings and safety instructions contained in this manual to
prevent personal injury or property damage.
To view the full line of Dimplex products, please visit
www.dimplex.com
2 www.dimplex.com
Table of Contents
Always use a qualied technician or
service agency to repair this replace.
!
NOTE: Procedures and techniques
that are considered important
enough to emphasize.
CAUTION: Procedures and
techniques which, if not carefully
followed, will result in damage to
the equipment.
WARNING: Procedures and
techniques which, if not carefully
followed, will expose the user to the
risk of re, serious injury, or death.
Welcome & Congratulations ..................... 3
IMPORTANT INSTRUCTIONS .....................4
Quick Reference Guide ......................... 6
Fireplace Installation ........................... 7
Framing .............................................7
Permanent Heat Disable ...............................10
Electrical ............................................11
Bathroom Use .......................................14
Final Assembly .......................................14
Wiring Diagrams ............................. 16
Operation ................................... 18
Maintenance ................................ 23
Warranty .................................... 24
Technical Support ............................ 26
www.dimplex.com 3
Welcome & Congratulations
Thank you and congratulations for purchasing an electric replace from
Dimplex. Please use our convenient online registration page to record
your model and serial numbers for future reference at
www.dimplex.com/register
NO NEED TO RETURN TO THE STORE
Questions with operation or assembly? Require Parts Information?
Product Under Manufacturer’s Warranty?
Contact us at: www.dimplex.com/customer_support
For Troubleshooting and Technical Support
OR Toll-Free 1-888-346-7539
In order to better serve you, please have your model and serial number
ready or register your product online before calling (See above)
Model and Serial
Number Label
Please carefully read and save these instructions.
CAUTION: Read all instructions and warnings carefully before starting
installation. Failure to follow these instructions may result in a possible
electric shock, re hazard and will void the warranty.
4 www.dimplex.com
When using electrical appliances,
basic precautions should always
be followed to reduce the risk of
re, electric shock, and injury to
persons, including the following:
Read all instructions before
installing or using this electric
replace.
This replace is hot when in
use. To avoid burns, do not let
bare skin touch hot surfaces.
The trim around the heater
outlet becomes hot during
heater operation.
DANGER: High temperatures
may be generated under certain
abnormal conditions. Do not
partially or fully cover or obstruct
the front of this heater.
Extreme caution is necessary
when any heater is used by
or near children or invalids
and whenever the unit is left
operating and unattended.
Young children should be
supervised to ensure that they
do not play with the appliance.
The appliance is not intended
for use by young children
or inrmed persons without
supervision.
IMPORTANT INSTRUCTIONS
Do not operate the unit after
it malfunctions. Disconnect
power at the service panel and
contact Technical Service for
service 1-888-346-7539.
⑦Do not use outdoors.
Never locate replace where it
may fall into a bathtub or other
water container.
To disconnect the replace,
turn the controls o, then
disconnect the circuit at the
main disconnect panel.
Do not locate the heater
immediately below a xed
socket-outlet.
Do not insert or allow foreign
objects to enter any ventilation
or exhaust opening as this may
cause an electric shock or re,
or damage to the heater.
To prevent a possible fire, do
not block air intakes or exhaust
in any manner.
All electrical heaters have hot
and arcing or sparking parts
inside. Do not use in areas
where gasoline, paint, or
ammable liquids are used or
stored.
www.dimplex.com 5
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
NO USER-SERVICABLE PARTS INSIDE
SAVE THESE INSTRUCTIONS
Use this heater only as
described in this manual. Any
other use not recommended by
the manufacturer may cause
re, electric shock or injury to
persons.
Do not burn wood or other
materials in the electric
replace.
Do not strike the replace
glass.
Always use a certied
electrician should new circuits
be required.
Disconnect all power supply
before performing any
cleaning, maintenance or
relocation of the unit.
When transporting or storing
the unit and cord, keep in a
dry place, free from excessive
vibration and store so as to
avoid damage.
WARNING: Remote control
contains small batteries.
Keep away from children.
If swallowed, seek medical
attention immediately.
WARNING: Do not install
battery backwards, charge, put
in re or mix with used or other
battery types - may explode or
leak causing injury.
!
NOTE: Changes or
modications not expressly
approved by the party
responsible for compliance
could void user's authority to
operate the equipment.
IMPORTANT INSTRUCTIONS
6 www.dimplex.com
Quick Reference Guide
1. The electrical information
regarding your electric replace
can be found on the rating label
located on the top of the unit.
Please use our convenient online
registration page to record your
model and serial numbers for
future reference at
www.dimplex.com/register
2. If you have any technical
questions or concerns regarding
the operation of your electric
replace, or require service
contact customer service at
1-888-346-7539.
3. For dimensions of your
replace, refer to Figure 1.
Figure 1
16.49 in
419 mm
15.82 in.
402 mm
15.00 in.
381 mm
5.79 in.
147 mm
4.34 in.
110 mm
XLF50 50.31 in [1278 mm]
XLF60 60.31 in [1532 mm]
XLF74 74.31 in [1887 mm]
XLF100 100.31 in [2548 mm]
XLF50 51.41 in [1306 mm]
XLF60 61.41 in [1560 mm]
XLF74 75.41 in [1941 mm]
XLF100 101.41 in [2576 mm]
www.dimplex.com 7
CAUTION: Ensure installation
does not allow replace to be
in direct contact with building
vapor barrier or insulation and
meets all local building code.
!
NOTE: A dedicated, properly
fused 15 Amp circuit is
recommended, rated for the
appropriate voltage (120V,
240V). A dedicated circuit will
be required if, after installation,
the circuit breaker trips or
fuse blows on a regular basis
when the heater is operating.
Additional appliances on the
same circuit may exceed the
current rating of the circuit
breaker.
WARNING: Construction
and wiring must comply with
local building codes and other
applicable regulations to
reduce the risk of re, electric
shock and injury to persons.
WARNING: To reduce the
risk of re, do not store or use
gasoline or other ammable
vapors or liquids in the vicinity
of the heater.
1. Select a location that is not
susceptible to moisture and is
away from drapes, furniture and
high trac.
Fireplace Installation
2. Unpack the replace and
hardware from the box.
!
NOTE: Leave the front glass
and partially reective glass
safely in the box until the time
you are ready to install them.
3. Store the replace in a safe, dry
and dust free location until you
are ready to install the replace.
Framing
CAUTION: Two people will be
required for various steps of this
procedure.
This design of this unit allows
three options for installation:
partial recess, ush mounted or
sub-surface mounted.
CAUTION: Sub-surface
mounting should be limited
to ½ in. (13 mm) to ensure
adequate air ow of heated air
out of the rebox area.
8 www.dimplex.com
Fireplace Installation
Installation Recommendations
with Overhanging Surfaces
Figure 2 provides the overhang
clearance recommendations for
the replace. Areas above the
replace are marked as follows:
Solid gray box (
) has
temperatures greater than 65°C
(149° F).
Hatched box (
) has
temperatures greater than 40°C
(104° F).
Clear box (
) has
temperatures less than 40°C
(104° F).
To frame the fireplace:
1. Prepare a wall with a framed
opening of 16 in. (40.6 cm) high
• XLF50 - 50 ⅝ in. (128.7 cm)
• XLF60 - 60 ⅝ in. (154.0 cm)
• XLF74 - 74 ⅝ in. (189.7 cm
• XLF100 - 100 ⅝ in. (255.7 cm)
wide, with a bottom sill that is
a minimum of 3.5 in. (9.0 cm)
deep (Figure 3). The sill can be
constructed to support the front
of the unit to allow the power
supply wires to easily be run
behind or ush with the back
of the unit and a pass thru hole
drilled for electrical wire routing.
Figure 3
2” x 6”
5 1/2" (14.0 cm)
16"
(40.6 cm)
2” x 4”
3 1/2" (9.0 cm)
XLF50: 50 5/8" (128.7 cm)
XLF74: 74 5/8" (189.7 cm)
XLF100: 100 5/8" (255.7 cm)
XLF60: 60 5/8" (154.0 cm)
WARNING: The top of the
replace is to be installed a
minimum of 8" (20.4 cm) from
the ceiling.
Figure 2
www.dimplex.com 9
Fireplace Installation
!
NOTE: It is recommended
that the bottom of the unit
be mounted between 30 in.
(76.2 cm) and 40 in. (101.6 cm)
from the ground to maintain an
optimized viewing angle of the
ame.
WARNING: Do not attempt
to wire your own new circuits.
To reduce the risk of re,
electric shock or injury to
persons, always use a licensed
electrician.
WARNING: Make sure the
circuit on which the replace is
to be installed has the power
cut o at the service panel until
installation is complete.
2. The unit is provided with an
installed ¾ in. (2.0 cm) trim.
Depending on the installation,
this trim can be removed by
removing the securing screws
and the 4 trim pieces.
3. Ensuring a minimum of 18 in.
(46.7 cm) of slack, route the
supply power wire through a
cable clamp (not included) and
in the opening in the back of the
unit. (Figure 4)
Figure 4
Grounding
Screw
Cable Clamp
4. Lift replace, from the bottom
and the handles located on the
back, and insert into opening to
the desired depth.
5. Using a bubble level (supplied)
ensure that the replace is level
within the framing. Adjust as
required.
6. Drive four supplied mounting
screws through the four
mounting holes located on the
inside surface of the replace
chassis, into wall studs
(Figure 5).
10 www.dimplex.com
Figure 5
Mounting Holes
Main Control Board
Flame Panel
Permanent Heat Disable
The replace heater can be
permanently disabled by
removing the electronic jumper on
the main control board. Disable
the heater before any other
installation takes place.
To disable the heater:
1. Locate the main control board
(Figure 5).
2. Pull out the electronic jumper
(shunt). The marking beside the
jumper is "HT EN" (Figure 6).
Figure 6
HT EN
Fireplace Installation
www.dimplex.com 11
Electrical
120V Installation - Direct
Wire
CAUTION: Use the appropriate
wire to meet local and national
electrical codes for rated power
consumption.
To 120V direct wire:
1. Cut the wire to an appropriate
length.
2. Connect the L wire from the unit
to the live wire from the power
supply with a wire nut.
3. Connect the N wire from the
unit to the neutral wire from the
power supply with a wire nut.
4. Connect the G wire from the
unit to the ground wire from the
power supply with a wire nut
or attach the grounding wire
to the cover with the provided
grounding screw, by placing the
wire in-between screw and lock
washer and tighten (Figure 4).
5. Make sure all wires are secure
and do not protrude past the
ame panel, so as not to be
visible after nal assembly.
6. Continue to the nal assembly
instructions.
120V Installation - Wall
Switch
!
NOTE: Use a single pole, single
throw (On/O) wall switch that is
rated for a minimum of
15 amps.
CAUTION: Use the appropriate
wire to meet local and national
electrical codes for rated power
consumption.
To wire through a wall switch:
1. Cut the wire to an appropriate
length.
2. Connect the L wire from the unit
to the live wire from the main
power through the wall switch,
ensuring all live connections
are connected with a wire nut
(Figure 7).
3. Connect the N wire from the
unit to the neutral wire from the
power supply with a wire nut.
4. Connect the G wire from the
unit to the ground wire from the
power supply with a wire nut
or attach the grounding wire
to the cover with the provided
grounding screw, by placing the
wire in-between screw and lock
washer and tighten (Figure 4).
Fireplace Installation
12 www.dimplex.com
FIREPLACE JUNCTION BOX
120 V
POWER
SUPPLY
(BREAKER
PANEL)
WHITE - N
BLACK – L1
WHITE – N
BLACK – L
GROUND - G
WALL
SWITCH
GROUND - G
5. Make sure all wires are secure
and do not protrude past the
ame panel, so as not to be
visible after nal assembly.
6. Continue to the nal assembly
instructions.
120V Installation - Plug Kit
WARNING: This heater is
not intended for use with an
extension cord. Plug the cord
directly into an ap propriate wall
receptacle.
To install a plug kit:
1. Locate the rear cover plate
about 12 in. (30.5 cm) from the
left side at the bottom (when
looking at the replace from the
back). Remove the 3 screws
that hold the plate (Figure 8).
2. Feed wire from plug kit into
opening and attach re-using the
3 screws from Step 1.
3. Connect the L wire from the unit
to the black wire of the plug kit.
4. Connect the N wire from the
replace to the white wire from
the plug kit.
5. Connect ground wire from the
replace to the green wire from
the plug kit.
6. Make sure all wire connections
are tight and that wires are
secured and do not protrude
past the ame panel, so as
not to be visible after nal
installation.
7. Continue to nal installation.
Figure 7
Fireplace Installation
www.dimplex.com 13
Figure 8
240V Installations
CAUTION: Use the appropriate
wire to meet local and national
electrical codes for rated power
consumption.
To 240V direct wire:
1. Connect the L1 wire from the
unit to the L1 wire from the
power supply with a wire nut.
2. Connect the L2 wire from the
unit to the L2 wire from the
power supply with a wire nut.
3. Connect the N wire from the
unit to the neutral wire from the
power supply.
4. Connect the G wire from the
unit to the ground wire from the
power supply with a wire nut
or attach the grounding wire
to the cover with the provided
grounding screw, by placing the
wire in-between screw and lock
washer and tighten (Figure 4).
5. Ensure that all wires are secure
and do not protrude past the
ame panel, so as not to be
visible after nal assembly.
6. Continue to the nal assembly
instructions.
Fireplace Installation
14 www.dimplex.com
Fireplace Installation
For Bathroom Use
If this unit is installed in a
bathroom it must be protected
by a GFCI receptacle or circuit.
If receptacle is used it must be
readily accessible.
This electrical appliance is NOT
watertight. To prevent electric
shock, it must be installed as to
prevent water from entering unit,
or installed away from showers,
tubs, etc. Never locate replace
where it may fall into a bathtub or
other water container.
Final Assembly
1. Locate and remove the screws
securing the partially reective
glass bracket to the unit
(Figure 9), along the top of the
opening, and set bracket and
screws aside.
2. Remove the provided suction
cup from the inside cavity of the
unit (not found in XLF50 units).
3. Before installation ensure that
the front glass and the partially
reective glass are clean.
Particles can be removed by
dusting lightly with a clean dry
cloth. To remove ngerprints
or other marks, the glass
can be cleaned with a damp
cloth. Ensure that the glass
has completely dried before
installation.
4. Carefully secure the suction cup
to the partially reective glass
on the reective side, and place
into the openings on either side
of the unit.
5. Tip the glass into the unit and
using the removed screws
secure the glass into the unit
with the provided bracket
(Figure 9). Remove the
suction cup.
6. Evenly space the large media
in the media tray along the back
of the media tray (for optimum
media eect), then carefully
pour and evenly distribute
the smaller media into the
Media Tray.
7. Carefully place the front glass
into the lip located at the bottom
of the opening of the rebox.
8. Tip the front glass into the
unit and secure using the
provided screws and Allen key.
(Figure 10).
!
NOTE: Ensure that the suction
cup and Allen key are kept for
any future maintenance
or
service.
www.dimplex.com 15
9. Install the provided screw
covers (Figure 11) by placing
tabs of the screw cover between
sides of the front glass bracket.
Fireplace Installation
Figure 9
Partially Reective
Glass
Partially Reective
Glass Bracket
Media Tray
Glass
Openings
Figure 10
16 www.dimplex.com
Figure 11
Figure 12A
Wiring Diagram
CUTOUTS
THERMAL
M
FLICKER MOTOR
FLAME LED ASSEMBLY
MEDIA LED ASSEMBLY
MEDIA LED ASSEMBLY
POWER ADAPTER
FAN
FAN
CERAMIC ELEMENT
MAIN CONTROL
BOARD
THERMISTOR
XLF50
www.dimplex.com 17
Wiring Diagram
CUTOUTS
THERMAL
FLICKER MOTOR
FLAME LED ASSEMBLY
MEDIA LED ASSEMBLY
MEDIA LED ASSEMBLY
POWER ADAPTER
FAN
FAN
CERAMIC ELEMENT
MAIN CONTROL
BOARD
THERMISTOR
XLF60
M
CUTOUTS
THERMAL
M
FLICKER MOTOR
FLAME LED ASSEMBLY
MEDIA LED ASSEMBLY
MEDIA LED ASSEMBLY
POWER ADAPTER
FAN
FAN
CERAMIC ELEMENT
POWER ADAPTER
RELAY BOARD
MAIN CONTROL
BOARD
THERMISTOR
XLF74, XLF100
Figure 12B
Figure 12C
18 www.dimplex.com
Operation
!
NOTE: The element retains
heat after shutdown. When
the heat is turned Off, there
is a 2-minute cool down
period before the fan shuts off
completely.
Remote Operation
The replace is supplied with an
IR multi-function remote control.
!
NOTE: To operate correctly, the
remote control must be pointed
towards the front of the unit.
Controls
The unit can be controlled by
either the manual controls which
are located on the upper right of
the replace or the remote
(Figures 13 and 14).
A. Standby
Turns the unit On and O.
Activated by pressing the
Standby button on the remote
or the unit.
The unit will turn On with the
same functions that it was set
to when it was turned O and
the intake temperature will be
indicated on the Display.
General Operation
WARNING: This electric
firebox must be properly
installed before it is used.
This rebox operates with
Comfort$aver
TM
technology,
which automatically adjusts the
fan speed and heater wattage to
safely and precisely match the
requirements of the room based
on the thermostat setting.
The heater operates such that
once the room reaches the set
point, the fan and heater will
continuously run at a low level,
to maintain the desired room
temperature. If the temperature
in the room rises signicantly, i.e.
sun coming through a window or
a central furnace turns on, the
heater will turn o and periodically
turn back on to circulate the air
around the unit, until the room
temperature drops and requires
the heater to be constantly on
again.
!
NOTE: The unit is designed
so that the fan will run
continuously while the heater
is on.
www.dimplex.com 19
Figure 13
A
C D E
H
Display
Figure 14
A
D
B
C
E
G
J
F
I
H
I
Operation
!
NOTE: When any button is
pressed on the unit the intake
temperature will be displayed on
the Display for 7 seconds.
B. Flame Eects
Turns the Flame Eect On
and O.
Activated by pressing the
button on the remote.
C. Heat ON/OFF
Turns the heater On and O.
Activated by pressing the
button on the remote or the
unit.
Indicated by the
icon and the
setpoint temperature will ash
on the display, then the intake
temperature will be displayed
before turning off.
!
NOTE: After the heater is
switched o, there is a 2 minute
fan delay, where the fan will
continue running before turning
o.
!
NOTE: The unit can be
operated in Heat Only Mode.
When the unit is only running
with the heater, the
icon will
continuously be displayed on
the Display.
C
J
20 www.dimplex.com
* The rst time the button is
pressed the current temperature
set point will be displayed for
2 seconds.
** The temperature can be
adjusted from 5 °C to 37 °C
(41 °F to 99 °F).
!
NOTE: Holding the and
the
buttons down for
two seconds on the manual
controls will change the
temperature scale from °C to °F,
or vice versa.
F.
Eco Operation
Runs the heater in a reduced
wattage range when activated.
Adjusted by pressing the
corresponding button on the
remote when the heater is on.
Indicated by the Display and a
reduced fan speed.
G.
Heat Boost
Turns the Heater Boost On and
O. Runs the unit at the full rated
wattage.
Activated and adjusted by
repeatedly pressing the
corresponding button on
the remote.
!
NOTE: The heater may emit
a slight, harmless odor when
rst used. This odor is a normal
condition caused by initial
heating of internal heater parts
and will not occur again.
D.
Temperature Down
Decreases the temperature
setting.
Adjusted by repeatedly
pressing the corresponding
button on the remote.*
Indicated by setpoint
temperature on the Display
decreasing and the speed of
the fan decreasing to reduce
the amount of heat being
projected into the room.**
E. Temperature Up
Increases the temperature
setting.
Adjusted by repeatedly
pressing the corresponding
button on the remote.*
Indicated by the setpoint on
the Display increasing and the
speed of the fan increasing to
increase the amount of heat
being projected into the room.**
Operation
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78

Dimplex XLF60 Le manuel du propriétaire

Catégorie
Chauffe-eau
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues