Cooper Crouse-Hinds CEAG KO Operating Instructions Manual

Taper
Operating Instructions Manual
GHG 980 700x P0001 D / E / F (_)
Betriebsanleitung
Sicherheitsschalter Industriebaureihe
KO
Operating instructions
Safety switches, Industrial design
KO
Mode d’emploi
Interrupteurs de sécurité, Type industriel,
KO
"En caso necesario podrá solicitar de
su representante Cooper Crouse-Hinds
/ CEAG estas instrucciones de servicio
en
otro idioma de la Union Europea"
"Se for necessária a tradução destas
instruções de operação para outro
idioma da
União Europeia, pode solicita-la junto
do seu representante Cooper Crouse-
Hinds / CEAG"
"Se desiderate la traduzione del
manuale operativo in un´altra lingua
della Comunit à Europea
potete richiederla al vostro
rappresentante Cooper Crouse-Hinds /
CEAG"
"Montagevejledningen kan oversættes
til andre EU-sprog og rekvireres hos
Deres
Cooper Crouse-Hinds / CEAG
leverandør"
"Indien noodzakelijk kan de vertaling
van deze gebruiksinstructie in een
andere EU-taal worden
opgevraagd bij Uw Cooper Crouse-
Hinds / CEAG - vertegenwoordiging"
"Tarvittaessa tämän käyttöohjeen
käännös on saatavissa toisella EU:n
kielellä Teidän
Cooper Crouse-Hinds / CEAG -
edustajaltanne"
"En översättning av denna montage-
och skötselinstruktion till annat EU -
språk kan vid behov
beställas från Er Cooper Crouse-Hinds
/ CEAG- representant"
""
""
" Εαν χρειασθει, µεταϕραση
των οδηγιων
χρησεως σε αλλη γλωσσα της
ΕΕ, µπορει να ζητηθει απο
τον Αντιπροσωπο της Cooper
Crouse-Hinds / CEAG"
Cooper Crouse-Hinds GmbH
22
22
2
Inhalt:
Inhalt ................................... 2
Maßbild .............................. 2
1 Technische Daten .............. 3
1.1 Technische Angaben ......... 3
1.2.1 Sicherheitsschalter 160 A.3p 3
1.2.2 Sicherheitsschalter 250 A 3p 3
1.2.3 Sicherheitsschalter 400 A 3p 3
1.2.4 Sicherheitsschalter 630 A 3p 3
1.2.5 Sicherheitsschalter 250 A 6p 4
1.2.6 Sicherheitsschalter 315 A 6p 4
1.2.7 Sicherheitsschalter 400 A 6p 4
1.2.8 Sicherheitsschalter 630 A 6p 4
2 Sicherheitshinweise ........... 3
3 Normenkonformität ............ 3
4 Verwendungsbereich ........ 4
5 Verwendung/Eigenschaften 4
6 Installation .......................... 4
6.1 Montage ............................. 4
6.2 Öffnen des Gerätes/
Elektrischer Anschluss ...... 4
6.3 Kabel- und Leitungs-
einführung; Verschluss
Stopfen. .............................. 5
6.4 Flanschplatten.................... 5
6.5 Schließen des Gerätes /
Deckelverschluss .............. 5
6.6 Inbetriebnahme.................. 5
7 Instandhaltung / Wartung .. 5
8 Reparatur / Instandsetzung 5
9 Entsorgung / Wieder- ........
verwertung ......................... 5
10 Konformitätserklärung ....... 12
Sicherheitsschalter
Industriebaureihe
KO
Safety switches, Industrial
design, KO
Interrupteurs de sécurité,
Type industriel jusqu’à KO
Contents:
Contents ................................ 2
Dimensional drawings .......... 2
1 Technical data ....................... 6
1.1 Technical details ................... 6
1.2.1 Safety switch 160 A 3p ......... 6
1.2.2 Safety switch 250 A 3p ......... 6
1.2.3 Safety switch 400 A 3p ......... 6
1.2.4 Safety switch 630 A 3p ......... 6
1.2.5 Safety switch 250 A 6p ......... 7
1.2.6 Safety switch 315 A 6p ......... 7
1.2.7 Safety switch 400 A 6p ......... 7
1.2.8 Safety switch 630 A 6p ......... 7
2 Safety instructions ................ 6
3 Conformity with standards ... 6
4 Field of application ................ 7
5 Application/Properties .......... 7
6 Installation ............................. 7
6.1 Mounting ............................... 7
6.2 Opening the device/
Electrical connection ............. 7
6.3 Cable entry;blanking plug .... 8
6.4 Flange plates ......................... 8
6.5 Closing the device/
cover closure ........................ 8
6.6 Taking into operation............. 8
7 Maintenance/Servicing ......... 8
8 Repairs/Overhaul. ................ 8
9 Disposal/Recycling .............. 8
10 Declaration of conformity ..... 12
Contenu:
Contenu ...................................... 2
Plans cotés ................................. 2
1 Caractéristiques techniques ..... 9
1.1 Données techniques .................. 9
1.2.1 Interrupteur de sécurité 160 A 3p 9
1.2.2 Interrupteur de sécurité 250 A 3p 9
1.2.3 Interrupteur de sécurité 400 A 3p 9
1.2.4 Interrupteur de sécurité 630 A 3p 9
1.2.5 Interrupteur de sécurité 250 A 6p 10
1.2.6 Interrupteur de sécurité 315 A 6p 10
1.2.7 Interrupteur de sécurité 400 A 6p 10
1.2.8 Interrupteur de sécurité 630 A 6p 10
2 Consignes de sécurité ............... 9
3 Conformité avec les normes ...... 9
4 Domaine d’utilisation .................. 10
5 Utilisation/Propriétés .................. 10
6 Installation ................................... 10
6.1 Montage ...................................... 10
6.2 Ouverture de l’appareil/.............
Raccordement électrique .......... 10
6.3 Entrées de câble;
bouchon de fermeture ............... 11
6.4 Plaques bridées ......................... 11
6.5 Fermeture de l’appareil/ ............
Fermeture du couvercle ............. 11
6.6 Mise en service .......................... 11
7 Maintien/Entretien ...................... 11
8 Réparation/Remise en état ........ 11
9 Évacuation des déchets / .........
Recyclage ................................... 11
10 Déclaration de conformité .......... 12
Cooper Crouse-Hinds GmbH
33
33
3
2 Sicherheitshinweise
Die Sicherheitsschalter sind nicht
für explosionsgefährdete
Bereiche geeignet.
Zielgruppe dieser Anleitung sind Elektro-
fachkräfte und Unterwiesene Personen.
Umbauten oder Veränderungen an den
Sicherheitsschaltern sind nicht gestattet.
Sie sind bestimmungsgemäß in unbe-
schädigtem und einwandfreiem Zustand
zu betreiben.
Als Ersatz und zur Reparatur dürfen nur
Originalteile von Cooper Crouse-Hinds /
CEAG verwendet werden.
Reparaturen dürfen nur von Cooper
Crouse-Hinds / CEAG oder einer qualifi-
zierten Elektrofachkraft in Übereinstim-
mung mit national geltenden Regeln
durchgeführt werden.
Vor Inbetriebnahme müssen die
Sicherheitsschalter entsprechend der im
Abschnitt 6 genannten Anweisung
geprüft werden.
Alle Fremdkörper müssen vor der ersten
Inbetriebnahme aus den Sicherheits-
schaltern entfernt werden.
Die Deckel der Sicherheitsschalter sind
nur in "EIN"-Stellung abnehmbar.
Beachten Sie die nationalen Sicherheits-
und Unfallverhütungsvorschriften und die
nachfolgenden Sicherheitshinweise in
dieser Betriebsanleitung, die wie dieser
Text in Kursivschrift gefasst sind!
Sicherheitsschalter, Industriebaureihe KO
1 Technische Daten
1.1 Technische Angaben
Zulässige Umgebungstemperatur: -20° C bis +40° C (Listenausführung)
Abweichende Temperaturen sind bei Sonderversionen möglich)
Zul. Lagertemperatur in Originalverpackung: -40° C bis +80° C
Schutzart nach EN 60529/IEC 529 : IP 65 (Listenausführung)
Nennspannung: bis 690 V
Schutzklasse nach EN 60598/IEC 598: II - mit Metallflansch
Leitungseinführung: laut Auftrag, im Rahmen der Bescheinigung
Prüfdrehmomente:
Deckelschrauben 2,50 Nm
Druckschraube der KLE M12 1,65 Nm
Druckschraube der KLE M16 - M20 2,50 Nm
Druckschraube der KLE M25 3,50 Nm
Druckschraube der KLE M32 - M 63 5,00 Nm
Druckschraube der Metall Ex- e KLE M16 7,5 Nm z.B. Typ E1WF/e, (Ex-e)
Druckschraube der Metall Ex- e KLE M20 10,0 Nm z.B. Typ E1WF/e, (Ex-e)
Druckschraube der Metall Ex- e KLE M25 15,0 Nm z.B. Typ E1WF/e, (Ex-e)
Druckschraube der Metall Ex- e KLE M32 25,0 Nm z.B. Typ E1WF/e, (Ex-e)
Druckschraube der Metall Ex- e KLE M40 30,0 Nm z.B. Typ E1WF/e, (Ex-e)
Druckschraube der Metall Ex- e KLE M50 45,0 Nm z.B. Typ E1WF/e, (Ex-e)
Gehäusematerial (Listenausführung): Stahlblech Pulverbeschichtet
3 Normenkonformität
Die Sicherheitsschalter erfüllen die Trenn-
eigenschaften nach DIN EN 60947 sowie das
Motorschaltvermögen AC 23 nach
DIN EN 60947 .
Weitere Anforderungen wie die IEC 947 - 3,
die EG- Richtlinie Elektromagnetische
Verträglichkeit (89/336/EWG) sowie die EG-
Richtlinie für elektrische Betriebsmittel zur
Verwendung innerhalb bestimmter
Spannungsgrenzen (73/23/ EWG) werden
von den Sicherheitsschaltern erfüllt.
Sie wurden entsprechend dem Stand der
Technik und gemäß DIN EN ISO 9001
entwickelt, gefertigt und geprüft.
1.2.1 Sicherheitsschalter 160 A Typ Moeller, P7, 3 polig
Bemessungsspannung: 400 V, 50/60 Hz
Bemessungsstrom: 160 A
Zulässige Kurzschlussvorsicherung: 160 A gG/gL
Schaltvermögen AC 23: 160 A
1.2.2 Sicherheitsschalter 250 A Typ Moeller, P7, 3 polig
Bemessungsspannung: 400 V, 50/60 Hz
Bemessungsstrom: 250 A
Zulässige Kurzschlussvorsicherung: 250 A gG/gL
Schaltvermögen AC 23: 250 A
1.2.3 Sicherheitsschalter 400 A Typ Moeller, P10, 3 polig
Bemessungsspannung: 400 V, 50/60 Hz
Bemessungsstrom: 400 A
Zulässige Kurzschlussvorsicherung: 400 A gG/gL
Schaltvermögen AC 23: 400 A
1.2.4 Sicherheitsschalter 630 A Typ Moeller, P10, 3 polig
Bemessungsspannung: 400 V, 50/60 Hz
Bemessungsstrom: 630 A
Zulässige Kurzschlussvorsicherung: 800 A gG/gL
Schaltvermögen AC 23: 630 A
Cooper Crouse-Hinds GmbH
44
44
4
6 Installation
Für das Errichten / Betreiben sind die
relevanten nationalen Vorschriften sowie die
allgemein anerkannten Regeln der Technik
maßgebend.
Unsachgemäße Installation und Betrieb
der Sicherheitsschalter kann zum Verlust
der Garantie führen.
5 Verwendung / Eigenschaften
Die Sicherheitsschalter dienen zur sicheren
allpoligen Abschaltung der elektrischen
Energie bei Wartungs-, Reinigungs- und
Reparaturarbeiten an Anlagen, Maschinen
und Antrieben.
Daneben sind die Sicherheitsschalter zur zu-
sätzlichen Abschaltung des Antriebes über
z.B. das vorgeschaltete Schütz mit einem
Hilfskontakt ausgerüstet, der gegenüber den
Hauptkontakten beim Einschalten nacheilt
und beim Ausschalten voreilt.
Der mechanische Aufbau der Sicherheits-
schalter ermöglicht, dass die Kontakte
zwangsweise geöffnet werden.
Die Sicherheitsschalter erfüllen die Trenn-
eigenschaften entsprechend der
DIN EN 60 947-3, (IEC 947-3).
Die Sicherheitsschalter können in "AUS"-
Stellung mit 3 Vorhängeschlösser gegen
unbefugtes Schalten gesichert werden, siehe
Bild 1 (Bügeldurchmesser der Vorhänge-
schlösser von 4 bis 6 mm).
Eine interne Verriegelungseinheit verhindert,
dass ein Öffnen des Gehäuses in der "AUS"-
Stellung möglich ist.
Angaben aus Punkt 3 und 4 sind bei der
Verwendung zu berücksichtigen.
Andere als die beschriebenen Anwendun-
gen sind ohne schriftliche Erklärung der
Fa. Cooper Crouse-Hinds / CEAG nicht
zulässig.
Beim Betrieb sind die in der Betriebsanlei-
tung unter Punkt 7 genannten Anweisun-
gen zu beachten.
Die Verantwortung hinsichtlich bestim-
mungsgemäßer Verwendung dieser
Sicherheitsschalter unter Bezugnahme
der in dieser Anleitung vorhandenen
Rahmenbedingungen (siehe technische
Daten) liegt allein beim Betreiber.
6.1 Montage
Die Montage des Gerätes kann ohne Öffnen
des Gehäuses erfolgen.
Die Sicherheitsschalter dürfen bei der
Direktmontage an der Wand nur an den
vorgesehenen Befestigungspunkten eben
aufliegen. Die gewählte Schraube muss der
Befestigungsöffnung angepasst sein (siehe
Maßbild) und sie darf die Öffnung nicht
beschädigen (z.B. Verwendung einer
Unterlegscheibe).
Die Sicherheitsschalter sind an allen
Befestigungspunkten zu befestigen.
Bei übermäßigem Anziehen der Befesti-
gungsschrauben, kann das Gerät beschä-
digt werden.
6.2 Öffnen des Gerätes /
Elektrischer Anschluss
Vor Öffnen der Geräte ist die Spannungs-
freiheit sicherzustellen bzw. sind geignete
Schutzmaßnahmen zu ergreifen.
Vor dem Öffnen ist der Schalter in "EIN"-
Stellung zu schalten.
Ein Schalten an der Achse des Schalter-
sockels bei geöffnetem Gehäuse ist nicht
zulässig (um den Schalter wieder korrekt
schließen zu können).
Der elektrische Anschluss des Betriebs-
mittels darf nur durch Elektrofach-
personal erfolgen.
Nach der Demontage von Einbauten zur
leichteren Einführung der Kabel und
Leitungen muss das Einbaugerät vor dem
elektrischen Anschluss wieder ordnungs-
gemäß montiert werden.
Die ordnungsgemäß abisolierten Anschluss-
leitungen der Kabel sind unter Berücksichti-
gung einschlägiger Vorschriften anzuschlie-
ßen.
Die Isolation der Anschlussleitungen
muss bis an die Klemme heranreichen.
Sicherheitsschalter, Industriebaureihe KO
1.2.5 Sicherheitsschalter 250 A Typ ABB OETL, 6 polig
Bemessungsspannung: 400 V / 690 V 50/60 Hz
Bemessungsstrom 40°C: 270 A
Zulässige Kurzschlussvorsicherung: 400 A / 400 A gG/gL
Schaltvermögen AC 23: 250 A / 250 A
1.2.6 Sicherheitsschalter 315 A Typ ABB OETL, 6 polig
Bemessungsspannung: 400 V / 690 V 50/60 Hz
Bemessungsstrom 40°C: 315 A
Zulässige Kurzschlussvorsicherung: 400 A /400 A gG/gL
Schaltvermögen AC 23: 315 A / 315 A
1.2.7 Sicherheitsschalter 400 A Typ ABB OETL, 6 polig
Bemessungsspannung: 400 V / 690 V 50/60 Hz
Bemessungsstrom 40°C: 500 A
Zulässige Kurzschlussvorsicherung: 500 A / 500A gG/gL
Schaltvermögen AC 23: 500 A / 350 A
1.2.8 Sicherheitsschalter 630 A Typ ABB OETL, 6 polig
Bemessungsspannung: 400 V / 690 V 50/60 Hz
Bemessungsstrom 40°C: 630 A
Zulässige Kurzschlussvorsicherung: 630 A / 630 A gG/gL
Schaltvermögen AC 23: 630 A / 350 A
Die Technischen Daten der einzelnen Einbauelemente müssen den entsprechenden
Anleitungen entnommen werden.
Maßzeichnungen und Stromlaufpläne entnehmen Sie den beigefügten Unterlagen.
4 Verwendungsbereich
Die Sicherheitsschalter sind zum Einsatz in
rauhen Industriebereichen geeignet!
Die eingesetzten Gehäusematerialien
einschließlich der außenliegenden Metallteile
bestehen aus hochwertigen Werkstoffen die
einen anwendungsgerechten Korrosions-
schutz und Chemikalienresistenz in "normaler
Industrieatmosphäre" gewährleisten.
Bei einem Einsatz in extrem aggressiver
Atmosphäre, können Sie zusätzliche Informa-
tionen über die Chemikalienbeständigkeit der
eingesetzten Kunststoffe, bei Ihrer zuständi-
gen Cooper Crouse-Hinds Niederlassung
erfragen.
Cooper Crouse-Hinds GmbH
55
55
5
6.5 Schließen des Gerätes /
Deckelverschluss
Der Schaltgriff der Sicherheitsschalter muss
in der EIN - Stellung stehen. Beim Aufsetzen
des Deckels ist darauf zu achten, dass die
Achse des Schalters in die Mitnehmeröffnung
des Schaltgriffes eingreift.
Alle Fremdkörper sind aus dem Gerät zu
entfernen.
Zum Schließen des Gerätes ist der
Gehäusedeckel mit dem Innenvierkant-
schlüssel des Vorreiberschlosses zu
verschließen.
6.6 Inbetriebnahme
Vor Inbetriebnahme des Betriebsmittels sind
die in den einzelnen nationalen Bestimmun-
gen genannten Prüfungen durchzuführen.
Außerdem ist vor der Inbetriebnahme die
korrekte Funktion und Installation des
Betriebsmittels in Übereinstimmung mit dieser
Betriebsanleitung und anderen anwendbaren
Bestimmungen zu überprüfen.
Unsachgemäßer Betrieb der Sicherheits-
schalter kann zum Verlust der Garantie
führen.
77
77
7
Instandhaltung / WartungInstandhaltung / Wartung
Instandhaltung / WartungInstandhaltung / Wartung
Instandhaltung / Wartung
Die für die Wartung / Instandhaltung von
elektrischen Betriebsmitteln geltenden
nationalen Bestimmungen sind einzuhal-
ten.
Vor Öffnen des Gehäuses Spannungs-
freiheit sicherstellen bzw. geeignete
Schutzmaßnahmen ergreifen.
Die erforderlichen Wartungsintervalle sind
anwendungsspezifisch und daher in Abhän-
gigkeit von den Einsatzbedingungen vom
Betreiber festzulegen.
Im Rahmen der Wartung sind vor allem die
Teile, von denen die Schutzart abhängt, zu
prüfen (z.B. Unversehrtheit des Gehäuses,
der Dichtungen und der Kabel- und Leitungs-
einführungen).
Besonders zu prüfen ist die sichere
Funktion der Deckelverriegelung sowie
die Unversehrtheit der Abschließvor-
richtung.
Sollte bei einer Wartung festgestellt werden,
dass Instandsetzungsarbeiten erforderlich
sind, ist Abschnitt 8 dieser Betriebsanleitung
zu beachten.
8 Reparatur / Instandsetzung
Instandsetzungsarbeiten / Reparaturen
dürfen nur unter Verwendung von Cooper
Crouse-Hinds / CEAG Originalersatzteilen
vorgenommen werden.
Bei Schäden am Leistungstrenner ist nur
ein Austausch zulässig. Im Zweifelsfalle
ist das betroffene Betriebsmittel an
Cooper Crouse-Hinds / CEAG zur
Reparatur zurückzugeben.
Umbauten oder Änderungen am Betriebsmit-
tel sind nicht gestattet, ausgenommen ist das
Anbringen von zusätzlichen KLE im Rahmen
der Zulassung des Betriebsmittels.
9 Entsorgung / Wiederverwertung
Bei der Entsorgung des Betriebsmittels sind
die jeweils geltenden nationalen Abfall-
beseitigungsvorschriften zu beachten.
Zur Erleichterung der Wiederverwertbarkeit
von Einzelteilen sind Kunststoffteile mit dem
Kennzeichen des verwendeten Kunststoffes
versehen.
Programmänderungen und
-ergänzungen sind vorbehalten.
Sicherheitsschalter, Industriebaureihe KO
6.3 Kabel-und Leitungs-
einführungen (KLE);
Verschluss Stopfen
Es dürfen generell nur geeignete KLE und
Verschluss Stopfen verwendet werden.
Für bewegliche Leitungen sind
Trompetenverschraubungen oder andere
geeignete Einführungen mit zusätzlicher
Zugentlastung zu verwenden.
Die für die eingebauten KLE maßgeben-
den Montagerichtlinien sind zu beachten.
Beim Einsatz von KLE mit einer niedrigeren
als der für das Gerät zutreffenden IP-
Schutzart (siehe Seite 3), wird die IP-
Schutzart des gesamten Gerätes reduziert.
Nicht benutzte Einführungsöffnungen sind mit
einem Verschluss Stopfen zu verschließen,
um die Mindestschutzart herzustellen.
Es ist darauf zu achten, dass bei der
Installation der KLE die für den Leitungs-
durchmesser geeigneten Dichtungseinsätze
verwendet werden. Bei ausschneidbaren
Dichtungseinsätzen ist sicherzustellen,dass
der Einsatz ordnungsgemäß dem Leitungs-
durchmesser angepasst wird.
Zur Sicherstellung der erforderlichen
Mindestschutzart sind die KLE fest anzuzie-
hen.
Bei übermäßigem Anziehen kann die
Schutzart beeinträchtigt werden.
6.4 Flanschplatten
Müssen Flanschplatten demontiert werden
(z.B. zum Bohren von Einführungsöffnungen),
ist bei der Montage zur Aufrechterhaltung
der Mindestschutzart auf den korrekten Sitz
der Flanschplatte zu achten.
Metallische Flanschplatten müssen in den
Potentialausgleich miteinbezogen
werden.
Der Leiter selbst darf nicht beschädigt
sein.
Die minimal und maximal anschließbaren
Leiterquerschnitte sind zu beachten.
Alle Schrauben und /oder Muttern der
Anschlussklemmen, auch die der nicht
benutzten, sind fest anzuziehen.
Achtung:
Das Aufpressen der Kabelschuhe auf das
Kabel ist fachgemäß durchzuführen.
Es ist sicherzustellen, dass die erfor-
derlichen Mindestluftstrecken eingehalten
werden.
Cooper Crouse-Hinds GmbH
66
66
6
3 Conformity with standards
The safety switches fulfil the isolating
properties acc. to DIN EN 60947 as well as
the AC 23 motor switching capacity acc. to
DIN EN 60947.
The safety switches meet further
requirements such as those of the
DIN EN 60947-3, IEC 947-3 and the EC
directive on electromagnetic compatibility (89/
336/EEC) as well as of the EC directive on
electrical equipment for use within defined
voltage limits (73/23/EEC).
They have been designed, manufactured
and tested according to the state of the art
and to DIN ISO 9001.
Safety switches, industrial design KO
1 Technical Data
1.1 Technical details
Perm.ambient temperature: -20° C up to +40° C (standard version)
Deviating temperatures possible with special versions.
Perm.storage temperature in original packing: -40° C to +80° C
Degree of protection. to EN 60529/IEC 529: IP 65 (standard version)
Insulation class acc. to EN 60598 / IEC 598: II - with metal flange
Test torques:
Cover screws 2.50 Nm
Cap nut of the plastic cable entry M12 1.65 Nm
Cap nut of the plastic cable entry M16 - M20 2.50 Nm
Cap nut of the plastic cable entry M25 3.50 Nm
Cap nut of the plastic cable entry M32 - M 63 5.00 Nm
Cap nut of the Ex-e metal cable entry M16 7.5 Nm e.g. type E1WF/e (Ex-e)
Cap nut of the Ex-e metal cable entry M20 10.0 Nm e.g. type E1WF/e (Ex-e)
Cap nut of the Ex-e metal cable entry M25 15.0 Nm e.g. type E1WF/e (Ex-e)
Cap nut of the Ex-e metal cable entry M32 25.0 Nm e.g. type E1WF/e (Ex-e)
Cap nut of the Ex-e metal cable entry M40 30.0 Nm e.g. type E1WF/e (Ex-e)
Cap nut of the Ex-e metal cable entry M50 45.0 Nm e.g. type E1WF/e (Ex-e)
Enclosure material (catalogue version): Sheet steel with powder coating
1.2 Safety switch 160 A Type Moeller, P7, 3 pole
Rated voltage: 400 V, 50/60 Hz
Rated current: 160 A
Perm. short circuit back-up fuse: 160 A gG/gL
Switching capacity AC 23: 160 A
1.2.2 Safety switch 250 A Type Moeller, P7, 3 pole
Rated voltage: 400 V, 50/60 Hz
Rated current: 250 A
Perm. short circuit back-up fuse: 250 A gG/gL
Switching capacity AC 23: 250 A
1.2.3 Safety switch 400 A Type Moeller, P10, 3 pole
Rated voltage: 400 V, 50/60 Hz
Rated current: 400 A
Perm. short circuit back-up fuse: 400 A gG/gL
Switching capacity AC 23: 400 A
1.2.4 Safety switch 630 A Type Moeller, P10, 3 pole
Rated voltage: 400 V, 50/60 Hz
Rated current: 630 A
Perm. short circuit back-up fuse: 800 A gG/gL
Switching capacity AC 23: 630 A
2 Safety instructions
The safety switches are not
suitable for hazardous areas.
For skilled electricians and
trained person in accordance with
national legislation, including the relevant
standards and, where applicable.
Modifications to the safety switch or
changes of its design are not permitted.
They shall be used for their intended
purpose and in perfect and clean
condition.
For replacement and repair, only genuine
Cooper Crouse-Hinds / CEAG spare parts
shall be used.
Repairs may only be carried out by
Cooper Crouse-Hinds / CEAG or a
qualified electrician in compliance with
the respective national regulations.
Prior to their taking into operation, the
safety switches shall be checked in
accordance with the instructions as per
section 6.
Before the initial operation, any foreign
matter will have to be removed from the
safety switch.
The safety switch cover can only be
removed in „On“ position.
Observe the national safety rules and
regulations for prevention of accidents as
well as the safety instructions included in
these operating instructions set in italics
the same as this text!
Cooper Crouse-Hinds GmbH
77
77
7
4 Field of application
The safety switches are suitable for heavy-
duty use in industrial areas!
The enclosure materials employed, including
the exterior metal parts, are made of high-
quality materials which ensure a corrosion
protection and resistance to chemical
substances corresponding to the
requirements in a „normal industrial
atmosphere“:
In case of use in an extremely aggresive
atmosphere, please refer to manufacture
Safety switches, industrial design KO
1.2.5 Safety switch 250 A Type ABB, OETL, 6 pole
Rated voltage: 400 V / 690 V 50/60 Hz
Rated current: 270 A
Perm. short circuit back-up fuse: 400 A / 400 A gG/gL
Switching capacity AC 23: 250 A / 250 A
1.2.6 Safety switch 315 A Type ABB, OETL, 6 pole
Rated voltage: 400 V / 690 V 50/60 Hz
Rated current: 315 A
Perm. short circuit back-up fuse: 400 A / 400 A gG/gL
Switching capacity AC 23: 315 A / 315 A
1.2.7 Safety switch 400 A Type ABB, OETL, 6 pole
Rated voltage: 400 V / 690 V 50/60 Hz
Rated current: 500 A
Perm. short circuit back-up fuse: 500 A / 500 A gG/gL
Switching capacity AC 23: 500 A / 350 A
1.2.8 Safety switch 630 A Type ABB, OETL, 6 pole
Rated voltage: 400 V / 690 V 50/60 Hz
Rated current: 630 A
Perm. short circuit back-up fuse: 630 A / 630 A gG/gL
Switching capacity AC 23: 630 A / 350 A
The technical data of the individual installation elements must be taken out from the respective
operating instructions. Dimensional drawings and circuit diagrams take you from the
attached documents.
5 Application / Properties
When maintenance, cleaning and repair work
is carried out on systems, machinery and
drives, the safety switches ensure the
reliable switching off on on poles of electrical
energy.
In addition to this, the safety switches are so
designed, that they also switch off the drive,
e.g. via the contactor that precedes the
auxiliary contacts. In relation to the main
contacts, this auxiliary contacts are lagging
while making and leading while breaking.
Due to the mechanical design of the safety
switch, compulsory opening of the contacts is
possible.
The safety switches fulfil the isolating
properties according to DIN EN 60 947-3,
(IEC 947-3).
To prevent unauthorized switching, the
switches can be locked in the „OFF“ position
by means of 3 padlocks, see Fig. 1, (shackle
diameter of the padlocks up to 4-6 mm).
A built-in locking device prevents the opening
of the enclosure in the „OFF“ position.
The data according to sections 3 and 4
shall be taken into account during use.
Applications other than those described
are not permissible without a written
declaration of consent from Messrs.
Cooper Crouse-Hinds / CEAG.
During operation the instructions stated
in section 7 of the operating instructions
shall be observed.
The sole responsibility with respect to the
suitability and proper use of the control
switches according to the basic
requirements of these instructions (see
technical data) lies with the operator.
6.1 Mounting
The switch can be mounted without opening
its enclosure (with the exception of the 10 A
safety switch).
When being mounted directly onto the wall,
the safety switches shall rest evenly only at
the fastening points provided for them.
The chosen screw shall match the fastening
hole (see dimensional drawing) and they shall
not damage the hole (e.g. use of a washer).
The safety switches are to be fastened to all
fastening spots.
If the screws are overtightened, the
apparatus may be damaged.
6 Installation
The relevant national regulations and the
generally recognized rules of engineering
apply for the installation and operation.
The improper installation and operation
of safety switches may result in the
invalidation of the guarantee.
6.2 Opening the device/
Electrical connection
Before opening the apparatus, ensure
that it has been isolated from the voltage
supply, or take appropriate protective
meassures.
Before opening , set the switch to the „ON“
position.
Switching at the shaft of the switch base
while the enclosure is open, is not
permitted (in order that the switch can be
properly reclosed).
The electrical connection of the apparatus
may only be carried out by skilled staff.
After dismantling built-in components in
order to facililate the introduction of
cables, such components will have to be
properly fitted in again prior to the
electrical connection.
The properly bared conductors of cables
shall be connected with due regard to the
respective regulations.
The insulation shall reach up to the
terminal. The conductor itself shall not be
damaged.
The minimum and maximum conductor
cross sections that can be connected
shall be observed .
Cooper Crouse-Hinds GmbH
88
88
8
6.36.3
6.36.3
6.3
Cable entries (KLE);Cable entries (KLE);
Cable entries (KLE);Cable entries (KLE);
Cable entries (KLE);
blanking plugsblanking plugs
blanking plugsblanking plugs
blanking plugs
Generally, only certified cable entries and
blanking plugs may be used.
Flexible cables shall be used with
trumpet-shaped cable glands or other
suitable entries with additional pull-relief.
The directives for mounting applicable to
the cable entries fitted shall be observed.
When mounting cable entries of a lower IP
protection than that of the apparatus (see
page 8), the IP protection of the whole unit will
be reduced.
In order to establish the minimum protection
category, unused entry holes shall be closed
with a certified blanking plug.
Care has to be taken that when fitting the
cable entries, sealing inserts appropriate to
the cable diameter be used. In case of
sealing inserts that are cut out, it will have to
be ensured that the insert is properly
adapted to the cable diameter.
In order to ensure the required minimum
protection category, the cable entries will
have to be tightened down.
Overtightening might impair the
protection category.
6.4 Flange plates
Should flange plates have to be removed (e.
g. for drilling entry openings), attention will
have to be paid to the proper fit of the flange
plate while mounting in order to maintain the
minimum protection category.
Metal flange plates shall be included in
the potential equalisation.
6.5
Closing the device/Closing the device/
Closing the device/Closing the device/
Closing the device/
cover closurecover closure
cover closurecover closure
cover closure
The switch toggle of the safety switches shall
be in ON position. When placing the cover
take care that the shaft of the switch engages
in the tappet hole of the switch toggle.
Any foreign matter shall be removed from
the apparatus.
To close the apparatus the enclosure cover
shall be closed using the internal square
spanner of the catch lock.
6.66.6
6.66.6
6.6
TT
TT
T
aking into operationaking into operation
aking into operationaking into operation
aking into operation
Prior to taking the apparatus into operation,
the tests specified in the relevant national
regulations are to be carried out. Apart from
that, the correct functioning and installation of
the apparatus in accordance with these
operating instructions and other applicable
regulations shall be checked.
The improper operation of safety
switches may result in the invalidation of
the guarantee.
7 Maintenance/Servicing
The relevant national regulations which
apply to the maintenance/servicing of
electrical apparatus, shall be observed.
Before opening the enclosure make sure
that the apparatus is disconnected from
the supply, or take the appropriate
protective measures.
The required maintenance intervals depend
on the respective application and shall
therefore be determined by the user
dependent on the conditions of use.
When servicing the apparatus, particularly
those parts that are decisive for the type of
protection against explosion, shall be
checked (e. g. intactness of the enclosure,
cable glands, efficacy of the gaskets).
The reliable working of the cover lock and
the integrity of the padlocking device
shall be especially checked.
If during servicing repairs prove to be neces-
sary, section 8 of these operating instructions
shall be observed.
8
Repairs/OverhaulRepairs/Overhaul
Repairs/OverhaulRepairs/Overhaul
Repairs/Overhaul
Repairs may only be carried out with genuine
Cooper Crouse-Hinds / CEAG spare parts.
In case the switch base is damaged, only
its replacement will be permitted. In case
of doubt, the respective apparatus will
have to be returned for repair to Cooper
Crouse-Hinds / CEAG.
Modifications to the apparatus or changes of
its design are not permitted, except for the
mounting of additional cable entries in accor-
dance with the approval of the apparatus.
9
Disposal/RecyclingDisposal/Recycling
Disposal/RecyclingDisposal/Recycling
Disposal/Recycling
When the apparatus is disposed of, the
respective national regulations on waste
disposal shall be observed,
In order to facilitate the recycling of individual
components, plastic parts are provided with
the identification mark of the plastic material
used.
Subject to modifications or supplement of the
product range.
Safety switches, industrial design KO
All screws and/or nuts of the supply
terminals, also of those remaining vacant,
shall be tightened down.
Attention:
The cable lugs should be crimped onto the
cable in a workmanlike manner.
Cooper Crouse-Hinds GmbH
99
99
9
1 Caractéristiques techniques
1.1 Données techniques
Température ambiante admissible: -20°C à +40°C (standard catalogue)
D’autres températures sont possibles avec des modèles spéciaux.
Temp. de stockage dans l’emballage original: -40°C à +80°C
Indice de protection selon EN 60529/CEI 529: IP 65 (standard catalogue)
Classe d’isolation selon EN 60598/CEI 598: II - avec plaque métalique
Couples de serrage testés:
Vis du couvercle 2,50 Nm
Ecrou borgne bas de l’entrée plastique M12 1,65 Nm
Ecrou borgne bas de l’entrée plastique M16-M20 2,50 Nm
Ecrou borgne bas de l’entrée plastique M25 3,50 Nm
Ecrou borgne bas de l’entrée plastique M32-M50 5,00 Nm
Ecrou borgne bas de l’entrée métallique M 16 7,5 Nm par ex. type, E1WF/e (Ex-e)
Ecrou borgne bas de l’entrée métallique M 20 10,0 Nm par ex. type, E1WF/e (Ex-e)
Ecrou borgne bas de l’entrée métallique M 25 15,0 Nm par ex. type, E1WF/e (Ex-e)
Ecrou borgne bas de l’entrée métallique M 32 25,0 Nm tpar ex. type, E1WF/e (Ex-e)
Ecrou borgne bas de l’entrée métallique M 40 30,0 Nm par ex. type, E1WF/e (Ex-e)
Ecrou borgne bas de l’entrée métallique M 50 45,0 Nm par ex. type, E1WF/e (Ex-e)
Enveloppe (standard catalogue): Tôle d’acier avec revêtement par poudre de
polyester
1.2.1 Interrupteur de sécurité 160 A Type Moeller, P7, 3 pôles
Tension nominale: 400 V, 50/60 Hz
Courant nominal: 160 A
Fusible de court-circuit adm. placé en amont: 160 A gG/gL
Puissance de coupure AC 23: 160 A
Interrupteurs de sécurité, type industriel KO
1.2.2 Interrupteur de sécurité 250 A Type Moeller, P7, 3 pôles
Tension nominale: 400 V, 50/60 Hz
Courant nominal: 250 A
Fusible de court-circuit adm. placé en amont: 250 A gG/gL
Puissance de coupure AC 23: 250 A
1.2.3 Interrupteur de sécurité 400 A Type Moeller, P7, 3 pôles
Tension nominale: 400 V, 50/60 Hz
Courant nominal: 400 A
Fusible de court-circuit adm. placé en amont: 400 A gG/gL
Puissance de coupure AC 23: 400 A
1.2.4 Interrupteur de sécurité 630 A Type Moeller, P7, 3 pôles
Tension nominale: 400 V, 50/60 Hz
Courant nominal: 630 A
Fusible de court-circuit adm. placé en amont: 800 A gG/gL
Puissance de coupure AC 23: 630 A
22
22
2
Consignes de sécuritéConsignes de sécurité
Consignes de sécuritéConsignes de sécurité
Consignes de sécurité
Les interrupteurs de sécurité ne
conviennent pas à l’emploi en
atmosphère explosive.
Les interrupteurs de sécurité ne doivent
pas être ni transformés ni modifiés.
Seuls des interrupteurs de sécurité intacts
et parfaits doivent être employés pour la
fonction qui leur est dévolue.
Seules des pièces de rechange
homologuées d’origine Cooper Crouse-
Hinds / CEAG doivent être utilisées comme
remplacement et pour des réparations.
Des réparations ne doivent être exécutées
que par Cooper Crouse-Hinds / CEAG ou
par un électricien qualifié en conformité
avec la règlementation nationale en
vigueur.
Avant la mise en service, les interrupteurs
de sécurité doivent être vérifiés selon
l’’instruction donnée dans la section 6.
Avant la première mise en service, tout
corps étranger doit être ôté de
l’interrupteur de sécurité.
Le couvercle de l’interrupteur de sécurité
ne peut être enlevé qu’en position
„fermée“.
Respectez les prescriptions nationales de
sécurité et de prévoyance contre les
accidents ainsi que les consignes de
sécurité qui suivent dans ce mode
d’emploi et qui sont mis en italique
comme ce texte!
3
Conformité avec les normesConformité avec les normes
Conformité avec les normesConformité avec les normes
Conformité avec les normes
Les interrupteurs de sécurité remplissent les
propriétés de séparation selon
DIN EN 60947 et possèdent la puissance de
coupure de moteur AC 23 selon
DIN EN 60947.
De plus, les interrupteurs de sécurité
correspondent à d’autres exigences comme
par ex. à ceux de la norme EN 60947-3,
DIN EN 60947 ainsi qu’à la directive CE
concernant du matériel électrique pour
l’emploi en des limites de tension définies
(73/23/CEE).
Ils ont été conçus, construits et testés selon
l’état actuel de la technique et selon DIN EN
ISO 9001.
5
Utilisation/PropriétésUtilisation/Propriétés
Utilisation/PropriétésUtilisation/Propriétés
Utilisation/Propriétés
Les interrupteurs de sécurité servent à la
coupure fiable de l’énergie électrique sur
tous les pôles, lorsque des travaux
d’entretien, de nettoyage et de réparation
sont exécutés sur des systèmes, des
machines et des appareils moteurs.
En outre, les interrupteurs de sécurité sont
en plus équipés pour la déconnexion de la
com-mande, par ex. au moyen les contacts
de auxiliaires en combinaison avec les
contacteurs placé en amont. Ce contacts de
auxiliaires est en retard des contacts
principaux lors de la mise en circuit et les
précède lors de la mise hors circuit.
Grâce à la construction mécanique des inter-
rupteurs de sécurité il est possible que les
contacts soient à ouverture forcée. Ils
remplissent les propriétés de coupure selon
DIN EN 60 947-3, CEI 947-3.
Les interrupteurs de sécurité peuvent, en
position ARRÊT, être équipés de trois
cadenas, prévenant ainsi tout risque de mise
hors-tension non autorisée, voir fig.
1(diamètre de l'étrier: jusqu'à 4-6 mm).
Un dispositif de verrouillage intégré prévient
l'ouverture de l'enveloppe en position
ARRÊT.
Pour l’emploi, les consignes des sections
3 et 4 devront être respectées.
Des emplois autres que ceux décrits ne
sont admis qu’avec l’approbation écrite
de Cooper Crouse-Hinds / CEAG.
Lors de l’utilisation, les instructions selon
point 7 de ce mode d’emploi doivent être
respectées.
Seul l’utilisateur est responsable de
l’emploi comme prévu de interrupteur de
sécurité, en tenant compte des conditions
générales exposées dans la notice (voir
Caractéristiques techniques).
6.2 Ouverture de l’appareil /
Raccordement électrique
Avant ouverture de l’enveloppe, mettre
l’appareil hors-tension et prendre les
mesures préventives appropriées.
Avant d'ouvrir l'enveloppe, l'interrupteur doit
être mis en position "MARCHE".
Lorsque l’enveloppe est ouverte, il n’est
pas permis de commuter sur l’arbre du
socle d’interrupteur (pour pouvoir
refermer l’interrupteur correctement).
Le raccordement électrique de l’appareil
ne doit se faire que par un personnel
qualifié.
Si des composants incorporés ont été
enlevés afin de faciliter l’introduction des
câbles, ceux-ci devront être remis dûment
en place avant le raccordement électrique.
Le raccordement des câbles dénudés se
fera selon les règlements correspondants.
Afin de maintenir le mode de protection,
la connexion des conducteurs doit se
faire très soigneusement.
L’isolation doit couvrir le conducteur
jusqu’à la borne. Le conducteur lui-même
ne doit pas être endommagé.
Interrupteurs de sécurité, type industriel KO
1.2.5 Interrupteur de sécurité 250 A Type ABB OETL, 6 pôles
Tension nominale: 400 V / 690 V 50/60 Hz
Courant nominal: 270 A
Fusible de court-circuit adm. placé en amont: 400 A / 400 A gG/gL
Puissance de coupure AC 23: 250 A / 250 A
1.2.5 Interrupteur de sécurité 315 A Type ABB OETL, 6 pôles
Tension nominale: 400 V / 690 V 50/60 Hz
Courant nominal: 315 A
Fusible de court-circuit adm. placé en amont: 400 A / 400 A gG/gL
Puissance de coupure AC 23: 315 A / 315 A
1.2.5 Interrupteur de sécurité 400 A Type ABB OETL, 6 pôles
Tension nominale: 400 V / 690 V 50/60 Hz
Courant nominal: 500 A
Fusible de court-circuit adm. placé en amont: 500 A / 500 A gG/gL
Puissance de coupure AC 23: 500 A / 350 A
1.2.5 Interrupteur de sécurité 630 A Type ABB OETL, 6 pôles
Tension nominale: 400 V / 690 V 50/60 Hz
Courant nominal: 630 A
Fusible de court-circuit adm. placé en amont: 630 A / 630 A gG/gL
Puissance de coupure AC 23: 630 A / 350 A
Les données techniques des différents éléments d'installation doivent être prises des
guides correspondants.
Des dessins de mesure et des stromlaufplaene d'électricité extraire-vous des
documents ci-joints.
4
Domaine d’utilisationDomaine d’utilisation
Domaine d’utilisationDomaine d’utilisation
Domaine d’utilisation
Les interrupteurs de sécurité conviennent au
service dur en zone industrielle!
Pour l’enveloppe, y compris les pièces
métalliques extérieures, des matières de
qualité supérieure ont été employées qui
assurent une protection appropriée contre la
corrosion et une résistance contre des
agents chimiques en „atmosphère industrielle
normale“:
Avec un une application dans extrême
agressif l'atmosphère, pouvoir vous
supplémentaire des information sur le la
stabilité le commencer des matière, avec
votre compétent Cooper Crouse-Hinds
établir demander.
6 Installation
Pour l’installation et l’exploitation de ces
appareils, la règlementation nationale en
vigueur (en Allemagne par ex. ElexV, loi de
sécurité des appareils) ainsi que les règles
de la technique généralement reconnues
devront être respectées.
L’installation ou l’utilisation incorrecte de
ces interrupteurs de sécurité à bornes
peut entraîner la perte de la garantie.
6.1 Montage
Le montage de l’appareil peut se faire sans
ouvrir l’enveloppe.
Dans le cas d'un montage directement au
mur, les interrupteurs ne doivent reposer au
niveau du mur que sur les points de fixation
prévus.
La vis choisie doit être en rapport avec le
pas de fixation (voir plan coté) et ne doit pas
avarier celui-ci (par ex. emploi d’une
rondelle).
Les interrupteurs de sécurité doivent être
attachés à tous les points d'ancrage.
Un serrage excessif des vis de fixation
peut endommager l’appareil.
Reportez vous à la notice de montage
correspondante.
6.3
Entrées de câble (KLE);Entrées de câble (KLE);
Entrées de câble (KLE);Entrées de câble (KLE);
Entrées de câble (KLE);
bouchons de fermeturebouchons de fermeture
bouchons de fermeturebouchons de fermeture
bouchons de fermeture
Généralement, seuls des bouchons de
fermeture et des entrées de câble certifiés
peuvent être utilisés.
Pour des câbles flexibles il faudra utiliser
des presses-étoupes à trompette ou
d’autres entrées convenables avec
décharge de traction supplémentaire.
Les directives pour le montage
applicables aux entrées de câble montées
doivent être respectées.
Si l’indice de protection des entrées de câble
montées est inférieur à celui de l’appareil ,
l’indice de protection de l’ensemble sera
réduit.
Des ouvertures d’entrée non utilisées doivent
être fermées avec un bouchon de fermeture
certifié pour établir l’indice de protection
minimum.
Lors du montage des entrées de câble il
faudra veiller à ce que des garnitures
d’étanchéité correspondant au diamètre du
câble soient utilisées. En cas de garnitures
qui doivent être coupées sur mesure, il
faudra faire attention à ce que la garniture soit
adaptée au diamètre du câble.
Les entrées de câble doivent être serrées à
fond afin de maintenir l’indice de protection
minimum.
Au cas où elles seraient forcées, cela
pourrait être nuisible à l’indice de
protection.
6.4
Plaques bridéesPlaques bridées
Plaques bridéesPlaques bridées
Plaques bridées
Au cas où des plaques bridées seraient
démontées (par ex. pour aléser des
ouvertures d’entrée), il faudrait veiller au
propre logement de la plaque bridée de
fixation lors du montage afin de maintenir
l’indice de protection minimum.
Des plaques bridées en métal doivent être
intégrées dans la compensation de
potentiel.
6.5
Fermeture de l’appareilFermeture de l’appareil
Fermeture de l’appareilFermeture de l’appareil
Fermeture de l’appareil
Fermeture du couvercleFermeture du couvercle
Fermeture du couvercleFermeture du couvercle
Fermeture du couvercle
Le garrot de l’interrupteur de sécurité doit
être mis en position „MARCHE“. Lorsque le
couvercle est posé, il faut veiller à ce que
l’axe de l’interrupteur s’engage dans le trou
d’entraînement du garrot de l’interrupteur.
Tout corps étranger doit être ôté de
l’appareil.
Le couvercle du boîtier doit être fermé et
verrouillé avec la clé spéciale prévue à cet
effet.
6.6
Mise en serviceMise en service
Mise en serviceMise en service
Mise en service
Avant la mise en service de l’appareil, les
vérifications spécifiées dans les règlements
nationaux individuels devront être exécutées.
De plus, il faudra vérifier son fonctionnement
et installation corrects en conformité avec ce
mode d’emploi et avec d’autres règlements y
applicables.
L’utilisation incorrecte de ces
commutateurs peut annuler la garantie.
7 Maintien/Entretien
La règlementation nationale en vigueur
pour le maintien et l’entretien du matériel
électrique devra être respectée.
Avant d’ouvrir l’enveloppe, débrancher
l’appareil de la tension ou prendre des
mesures préventives appropriées.
Les intervalles de service requis dépendent
de l’emploi spécifique et devront donc être
fixés par l’utilisateur en tenant compte des
conditions d’utilisation.
En particulier, le fonctionnement fiable du
verrouillage du couvercle ainsi que
l’intégrité du dispositif de verrouillage
devront être vérifiés.
Si, lors d’un entretien, on constate que des
travaux d’entretien sont nécessaires, il
faudra suivre l’alinéa de ce mode d’emploi.
8
Réparations / Remise en étatRéparations / Remise en état
Réparations / Remise en étatRéparations / Remise en état
Réparations / Remise en état
Des réparations ne doivent se faire qu’à
l’aide des pièces de rechange d’origine
Cooper Crouse-Hinds / CEAG.
En cas de défauts sur le socle
d’interrupteur, seul un remplacement sera
admissible. Dans le doute, l’appareil
défectueux devra être renvoyé à Cooper
Crouse-Hinds / CEAG pour être réparé.
Il n’est pas permis de transformer ou de
modifier ces appareils, sauf pour le montage
des entrées de câble supplémentaires en
conformité avec l’homologation des
appareils.
9
Évacuation des déchets/Évacuation des déchets/
Évacuation des déchets/Évacuation des déchets/
Évacuation des déchets/
RecyclageRecyclage
RecyclageRecyclage
Recyclage
Lors de l’évacuation de ce matériel
électrique, la règlementation nationale
respective en vigueur devra être respectée.
Pour faciliter la réutilisation des composants
individuels, des pièces en matière plastique
ont été repérées de la marque distinctive de
la matière plastique employée.
Sous réserve de modification ou
d’informations supplémentaires.
Interrupteurs de sécurité, type industriel KO
Les sections minimales et maximales ad-
missibles des conducteurs doivent être
respectées .
Toutes les vis et/ou écrous des bornes de
connexion, aussi celles des bornes non
utilisées, doivent être serrées à fond.
Attention: L’emmmanchement par
pression des cosses au câble doit se faire
de manière appropriée. Il faut assurer que
les entrefers minimums soient respectés .
Cooper Crouse-Hinds GmbHCooper Crouse-Hinds GmbH
Cooper Crouse-Hinds GmbHCooper Crouse-Hinds GmbH
Cooper Crouse-Hinds GmbH
Neuer Weg-Nord 49
D 69412 Eberbach / Germany
Phone +49 (0) 6271 / 806-500
Fax +49 (0) 6271 / 806-476
Internet: www.CEAG.de
GHG980700xP0001 D/E/F (_)/ Auflage 0604 / x
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Cooper Crouse-Hinds CEAG KO Operating Instructions Manual

Taper
Operating Instructions Manual

dans d''autres langues