Manual No. 80024252 Revision A
Outdoor Portable Generator
Operator’s Manual
Model Number _____________________________
Revision __________________________________
Serial Number ______________________________
Date Purchased ____________________________
Copyright © 2017. Briggs & Stratton Corporation
Milwaukee, WI, USA. All rights reserved.
BRIGGS & STRATTON is a registered
trademark of Briggs & Stratton Corporation
800-743-4115
BRIGGSandSTRATTON.COM
Not for
Reproduction
EN2 BRIGGSandSTRATTON.COM
Equipment Description
Table of Contents
Equipment Description.........................2
Features and Controls .........................5
Operation....................................7
Maintenance ................................12
Storage ....................................15
Troubleshooting/Specifications .................16
Warranty ...................................20
Register Your Product
To ensure prompt and complete warranty coverage, register
your product online at www.onlineproductregistration.com.
Symbols and Meanings
Signal Meaning
DANGER
Indicates a hazard which, if not avoided, will
result in death or serious injury.
WARNING
Indicates a hazard which, if not avoided, could
result in death or serious injury.
CAUTION
Indicates a hazard which, if not avoided, could
result in minor or moderate injury.
NOTICE
Indicates information considered important, but
not hazard-related.
Symbol Name Explanation
Safety Alert
Symbol
Indicates a potential personal injury
hazard.
Operator’s
Manual
Failure to follow warnings,
instructions and operator’s manual
could result in death or serious
injury.
Toxic Fumes
Engine exhaust contains carbon
monoxide, a poisonous gas that
could kill you in minutes. You
cannot smell it or see it.
Fire
Fuel and its vapors are extremely
flammable which could cause
burns or fire resulting in death or
serious injury.
Engine exhaust could cause fire
resulting in death or serious injury.
Electric
Shock
Generator could cause electrical
shock resulting in death or serious
injury.
Hot Surface
Muffler could cause burns or
resulting in serious injury.
WARNING! The engine exhaust from this product
contains chemicals known to the State of California to
cause cancer, birth defects, or other reproductive harm.
WARNING! Certain components in this product and
related accessories contain chemicals known to the
State of California to cause cancer, birth defects or
other reproductive harm. Wash hands after handling.
Equipment Description
Read this manual carefully and become familiar
with your outdoor generator. Know its applications,
its limitations, and any hazards involved. Save
these instructions for future reference.
The outdoor generator is an engine-driven, revolving field,
alternating current (AC) generator equipped with a voltage
regulator. The generator is designed to supply electrical power
for operating compatible electrical lighting, appliances, tools
and motor loads. The voltage regulator within the generator is
designed to automatically maintain output voltage level.
The portable generator produces power that can be used for
outdoor items using extension cords or for first time temporary
home power restoration. Before your next home power outage,
install a listed transfer switch. A transfer switch is a separate
device installed by a licensed electrician that allows the portable
generator to be cord connected, using the locking receptacle,
directly into your home’s electrical system. Extension cords
connected to the portable generator’s control panel are not
intended to be a long term solution when connected to items
inside your home.
Every effort has been made to ensure that the information in this
manual is both accurate and current. However, the manufacturer
reserves the right to change, alter or otherwise improve the
generator and this documentation at any time without prior notice.
NOTICE If you have questions about intended use, contact an
authorized service dealer. This equipment is designed to be used
with Briggs & Stratton authorized parts only.
This spark ignition system complies with the Canadian
standard ICES-002.
System Ground
The generator has a system ground that connects the generator
frame components to the ground terminals on the AC output
receptacles. The system ground is connected to the AC neutral
wire (the neutral is bonded to the generator frame).
Special Requirements
There may be Federal or State regulations, local codes, or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician,
electrical inspector, or
the local agency having jurisdiction.
This generator is not intended to be used at a construction
site or similar activity as defined by NFPA 70-2014 (NEC)
section 590.6.
Not for
Reproduction
EN3
To Temporarily Restore Power Using
Extension Cords
1. Only use cords marked for outdoor use rated for your
loads.
To Temporarily provide power
using extension cords
Total
Amperage
Minimum Guage, Outdoor Rated
Up to 50 FT (15 M) Up to 100 FT (30 M)
Up to 13A
16
14
Up to 15A
14
12
Up to 20A
12
10
Up to 30A
10
8
2. Follow cord safety instructions.
3. Extension cords running directly into the home
increase your risk of carbon monoxide poisoning
through openings. Install carbon monoxide alarm(s).
4. Before your next home power outage, install a listed*
transfer switch.
* Certified by a Nationally Recognized Testing Laboratory that the
product complies to appropriate product safety test standards.
To Restore Home Power Using a Listed
Transfer Switch
Connections to your home’s electrical system must use a
listed transfer switch installed by a licensed electrician. The
connection must isolate the generator power from the utility
power and comply with all applicable laws and electrical
codes. Power your home with a 30 Amp transfer switch
system.
Equipment Description
120V
OUTLET
120/240V
Outlet
Transfer
Switch
Typical Indoor Items
Not for
Reproduction
EN4 BRIGGSandSTRATTON.COM
Equipment Description
Air Cleaner — Filters engine intake air.
Battery Charger Jack — Use battery charger to keep the
starting battery charged and ready for use.
Choke Control — Used when starting a cold engine.
Engine Identification — Provides model, type and code of
engine.
Fuel Cap — Add unleaded fuel here.
Fuel Valve — Used to turn fuel supply on and off to engine.
Grounding Fastener — Consult your local agency having
jurisdiction for grounding requirements in your area.
Identification Label — Provides model and serial number of
generator.
Oil Drain Plug — Drain engine oil here.
Oil Fill Cap/Dipstick — Check and add engine oil here.
Recoil Starter — Used to start the engine manually.
Spark Arrester Muffler — Exhaust muffler lowers engine
noise and is equipped with a spark arrester screen.
Engine Identification
Oil Fill Cap/Dipstick
Oil Drain Plug
Fuel Cap
Grounding Fastener
Choke Control
Spark Arrester Muffler
Air Cleaner
Identification Label
Fuel Valve
Battery Charger Jack
Recoil Starter
Not for
Reproduction
EN5
Features and Controls
120 Volt AC, 20 Amp, GFCI Duplex Receptacles — Used
to supply 120 Volt AC, single phase, 60 Hz power for
electrical lighting, appliance, tool and motor loads.
120/240 Volt AC, 30 Amp Locking Receptacle — Used to
supply 120 / 240 Volt AC, single phase, 60 Hz power for
electrical lighting, appliance, tool and motor loads.
Circuit Breakers (AC) — The 120 Volt AC, 20A GFCI
duplex receptacles are provided with “push to reset” 20
Amp circuit breakers to protect the generator against
electrical overload.
Hour Meter — Displays and records how many hours your
generator has run (up to 9,999.9).
Low Oil Shutdown — This unit is equipped with a low oil
protection device. Oil must be at proper level for engine
to run. If the engine oil drops below a preset level, an oil
switch will stop the engine. Check oil level with dipstick.
Rocker Switch Circuit Breaker — The 30 Amp locking
receptacle is provided with a 2 pole rocker switch circuit
breaker to protect the generator against electrical overload.
Start Switch — Turn key to START position to start engine.
Turn key to OFF position to switch off engine.
120/240 Volt AC, 30 Amp
Locking Receptacle
120 Volt AC, 20 Amp
GFCI Duplex Receptacles
Circuit Breakers
Low Oil
Shutdown
Compare the illustrations with your generator to familiarize yourself with the locations of various
controls and product warnings.
Hour Meter
202997
Start
Switch
Rocker Switch
Circuit Breaker
Not for
Reproduction
EN6 BRIGGSandSTRATTON.COM
Features and Controls
80021107
Read and follow
Operating Instructions
before running or
servicing engine.
Gasoline is flammable.
Allow engine to cool
at least 2 minutes
before refueling.
Engines emit carbon
monoxide that can
kill you. Operate
only outdoors.
Muffler area
temperature may
exceed 150°F (65°C).
Do not touch hot parts.
Lire et suivre les instructions
d´utilisation avant de démarrer
ou effectuer l´entretien du moteur.
L´essence est inflammable.
Laisser refroidir le moteur
pendant au moins 2 minutes
avant de faire le plein.
Autour du silencieux, la
température peut dépasser
150°F (65°C). Ne pas toucher
des pièces chaudes.
WARNING
AVERTISSEMENT
DANGER
Les moteurs émettent du monoxyde
de carbone pouvant vous tuer.
Ne faire fonctionner qu’à l’extérieur.
Muffler
Point away
from home
Not for
Reproduction
EN7
Operation
Operation
Step 1: Safe Location
Before starting the portable generator there are two equally
important safety concerns regarding carbon monoxide
poisoning and fire that must be addressed.
Operation Location to Reduce the Risk of
Carbon Monoxide Poisoning
The engine exhaust of all fossil fuel burning equipment,
such as a portable generator, contains carbon monoxide,
a poisonous gas that could kill you in minutes. You cannot
smell it, see it, or taste it. Even if you do not smell exhaust
fumes, you could still be exposed to carbon monoxide gas.
By law it is required in many states to have a carbon
monoxide alarm in operating condition in your home. A
carbon monoxide alarm is an electronic device that detects
hazardous levels of carbon monoxide. When there is
a buildup of carbon monoxide, the alarm will alert the
occupants by flashing visual indicator light and alarm.
Smoke alarms cannot detect carbon monoxide gas.
DANGER! Engine exhaust contains carbon
monoxide, a poisonous gas that could kill you in
minutes. You cannot smell it, see it, or taste it.
Even if you do not smell exhaust fumes, you could still be
exposed to carbon monoxide gas.
Operate this product only outdoors far away from
windows, doors and vents to reduce the risk of carbon
monoxide gas from accumulating and potentially being
drawn towards occupied spaces.
Install battery-operated carbon monoxide alarms or
plug-in carbon monoxide alarms with battery back-up
according to the manufacturer’s instructions. Smoke
alarms cannot detect carbon monoxide gas.
Do not run this product inside homes, garages,
basements, crawlspaces, sheds, or other partially-
enclosed spaces even if using fans or opening doors
and windows for ventilation. Carbon monoxide can
quickly build up in these spaces and can linger for
hours, even after this product has shut off.
Always place this product downwind and point the
engine exhaust away from occupied spaces.
If you start to feel sick, dizzy, or weak while using this
product, get to fresh air right away. See a doctor. You may
have carbon monoxide poisoning.
Carbon monoxide alarm
Install carbon monoxide alarms inside
your home. Without working carbon
monoxide alarms, you will not realize
you are getting sick and dying from
carbon monoxide poisoning.
CARBON MONOXIDE ALARM(S)
USE OUTDOORS - AVOID CARBON MONOXIDE POISONING
point away
from home
MUFFLER
To better educate yourself about all carbon monoxide risks,
go to www.takeyourgeneratoroutside.com.
Not for
Reproduction
EN8 BRIGGSandSTRATTON.COM
Operation
Operation Location to Reduce the Risk of Fire
WARNING!
Exhaust heat/gases could ignite
combustibles, structures or damage fuel tank
causing a fire, resulting in death or serious injury.
Portable generator must be at least 5 ft. (1.5 m) from
any structure, overhang, trees, windows, doors, any wall
opening, shrubs, or vegetation over 12 in. (30.5 cm) in
height.
Do not place portable generator under a deck or other
type of structure that may confine airflow. Smoke alarm(s)
must be installed and maintained indoors according to the
manufacturer’s instructions/recommendations.
Carbon monoxide alarms cannot detect smoke.
Do not place portable generator in manner other than
shown.
MUFFLER
5 ft. (1.5 m)
min.
5 ft. (1.5 m)
min.
Not for
Reproduction
EN9
Operation
Step 2: Oil and Fuel
The generator engine is shipped from the factory filled with
10W30 oil. This allows for generator operation in a wide
range of temperature and climate conditions. For checking/
adding or changing oil see Maintenance.
Fuel must meet these requirements:
Clean, fresh, unleaded fuel with a minimum of 87
octane.
Gasoline with an ethanol content up to 10% is
acceptable.
E10
E15
NOTICE Do not mix oil in fuel or modify engine to run on
alternate fuels. Use of unapproved fuels could damage
engine and will not be covered under warranty.
See High Altitude for 5,000 ft. and above.
WARNING! Fuel and its vapors are extremely
flammable which could cause burns or fire
resulting in death or serious injury.
Do not refuel during operation.
Turn engine off and let it cool at least 2 minutes before
removing fuel cap.
Fill fuel tank outdoors. Keep fuel away from sparks, open
flames, pilot lights, heat, and other ignition sources.
Check fuel lines, tank, cap and fittings frequently for
cracks or leaks. Replace if necessary.
1. Slowly remove fuel cap to relieve pressure in tank.
2. Slowly add unleaded fuel to fuel tank. Be careful not
to fill above lip. This allows adequate space for fuel
expansion.
3. Install fuel cap and let any spilled fuel evaporate
before starting engine.
High Altitude
At altitudes over 5,000 ft. (1524 m), a minimum 85 octane
fuel is acceptable. To remain emissions compliant, high
altitude adjustment is required. Operation without this
adjustment will cause decreased performance, increased
fuel consumption,
and increased emissions.
See an authorized Briggs & Stratton dealer for high altitude
adjustment information. Operation of the engine at altitudes below
2,500 ft. (762 m) with the high altitude kit is not recommended.
Transporting
When transporting equipment with a vehicle or trailer, turn fuel
shutoff valve to off (0) position. Do not tip engine or equipment at
an angle which causes fuel to spill.
Step 3: Generator Start Up
Disconnect battery charger and all electrical loads from the
generator. Use the following start instructions:
1. Make sure unit is outdoors on a level surface.
NOTICE Failure to operate the unit on a level surface may
cause the unit to shut down.
2. Turn the fuel valve to the on (I) position.
3. Pull choke control out to close choke ( ).
4. Turn and hold key in start switch to START position
until generator starts. DO NOT hold key in START
position for more than 5 seconds. Pause for at least
30 seconds between starting attempts.
NOTICE If battery is discharged, turn key in start switch
to RUN position, grasp recoil handle and pull slowly until
slight resistance is felt. Then pull rapidly one time only to
start engine.
5. Open choke gradually as engine warms up by pushing
in on choke handle.
NOTICE If engine starts but fails to run, see Low Oil
Shutdown in Features and Controls.
Fuel Valve
Start Switch
Not for
Reproduction
EN10 BRIGGSandSTRATTON.COM
Step 4: Connecting Electrical Loads
Using Extension Cords
Use only grounded extension cords marked for outdoor
use rated for your loads. Follow cord safety instructions.
WARNING! Damaged or overloaded extension
cords could overheat, arc, and burn resulting in
death or serious injury.
NOTICE For best results when plugging into the 120 Volt
receptacles, plug items to be powered in sequence as
shown.
NOTICE For generator output required see Generator
Capacity. Connect electrical loads in off position then turn
on for operation.
120 Volt AC, 20 Amp, GFCI Duplex Receptacles
Use each receptacle to operate 120 Volt AC, single-phase,
60 Hz electrical loads requiring up to 2,400 Watts (2.4 kW)
at 20 Amps of current.
Ground Fault Protection
The duplex receptacles are equipped with Ground Fault
Circuit Interrupter (GFCI) protection. The GFCI protects
against electrical shock that may be caused if your body
becomes a path which electricity travels to reach ground.
When protected by a GFCI, one may still feel a shock, but
the GFCI is intended to cut current off quickly enough so
that a person in normal health should not suffer any serious
electrical injury.
WARNING! Generator voltage could cause
electrical shock or burn resulting in death or
serious injury. Contact with the hot and neutral
conductor at the same time could cause electrical shock
or burn, even if the circuit is GFCI protected.
Testing the GFCI
While generator is running, test each GFCI receptacle prior
to use, as follows:
Push the “Test” button. The “Reset” button should
pop out, which should allow no power to reach the
receptacle.
Press the “Reset” button firmly until it is fully in place
and locks in that position. If the GFCI receptacle does
not reset properly, do not use the receptacle. Call
or take your generator to a local Briggs & Stratton
authorized service dealer.
If the GFCI trips by itself at any time, reset and test the
receptacle.
Operation
1
4
2
3
Not for
Reproduction
EN11
Operation
120/240 Volt AC, 30 Amp, Locking Receptacle
Use a NEMA L14-30 plug with this receptacle. Connect a
4-wire cord set rated for 250 Volt AC loads at 30 Amps. The
generator’s locking receptacle is not protected by a GFCI.
This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 7,200 Watts of power (7.2kW)
at 30 Amps for 240 Volts or two independent 120 Volt
loads at 30 Amps each.
Generator Capacity
To make sure your generator can supply enough running
watts and starting watts for the items you will power at the
same time, follow these simple steps:
1. Select the items you will power at the same time. See
following list for typical wattages.
* Typical wattages listed are approximate only. Check tool
or appliance for actual wattage.
** Per Briggs & Stratton 628K, Starting Watts represents
the momentary electrical current the generator can
provide to start electric motors. Starting Watts does
not represent the power required to continuously run
electrical loads. Starting Watts is the maximum current
that can momentarily be supplied when starting a motor,
multiplied by the generator’s rated voltage.
2. Total the running watts. This is the amount of power
your generator must produce to keep your items
running. See following example:
Example
Total running watts = 2355
Highest starting watts = 2000
Total generator watts required = 4355
3. Estimate the starting watts you will need. Because not
all motors start at the same time, total starting wattage
can be estimated by adding only the item with the
highest additional starting watts requirements to the
total running watts from step 2.
Power Management
To manage generator power, sequentially add loads as
follows:
1. With nothing connected to generator, start the engine
outdoors.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Never add more loads than the generator capacity. Take
special care to consider surge loads in generator capacity.
Step 5: Generator Shutdown
1. Turn off and unplug all electrical loads from generator
panel receptacles. Never stop engine with electrical
devices plugged in and turned on.
2. Let engine run at no-load for one minute to stabilize
internal temperatures of engine and generator.
3. Turn key in start switch to 0FF (0) position.
4. Move fuel valve to off (0) position.
4-Wire Cord Set
240V
120V
W (Neutral)
X (Hot)
Y (Hot)
Ground (Green)
120V
NEMA L14-30
Tool or Appliance Running Watts Starting Watts
Window air conditioner
1200 1800
Refrigerator 800 2000
Television 280
Light (75 Watts) 75
2355 Total
Running Watts
2000 Highest
Starting Watts
Tool or Appliance
Running
Watts*
Starting
Watts**
Light Bulb - 75 Watt 75 -
Sump Pump 800 1200
Refrigerator/Freezer 800 2000
Water Well Pump - 1/3 HP 1000 2000
Window AC - 10,000 BTU 1200 1800
Furnace Fan Blower - 1/2 HP 800 1300
Microwave Oven - 1000 Watt 1000 -
Color Television - 42” 280 -
Personal Computer w/17” monitor 800 -
Garage Door Opener - 1/2 HP 480 520
Not for
Reproduction
EN12 BRIGGSandSTRATTON.COM
Maintenance
Maintenance
Maintenance Schedule
Follow the hourly or calendar intervals, whichever occurs
first. More frequent service is required when operating in
adverse conditions noted below.
1
Service more often under dirty or dusty conditions.
General Recommendations
Regular maintenance will improve the performance and
extend the life of the generator. See any authorized dealer
for service.
The generator’s warranty does not cover items that have
been subjected to operator abuse or negligence. To
receive full value from the warranty, the operator must
maintain the generator as instructed in this manual.
All service and adjustments should be made at least once
each season. A new spark plug and clean air filter assure
proper fuel-air mixture and help your engine run better and
last longer. Follow requirements in Maintenance Schedule.
Emissions Control
Maintenance, replacement, or repair of the emissions
control devices and systems may be performed by any
non-road engine repair establishment or individual.
However, to obtain ”no charge” emissions control service,
the work must be performed by a factory authorized dealer.
See Emissions Warranty.
Cleaning
Daily or before use, look around and underneath
the generator for signs of oil or fuel leaks. Clean any
accumulated debris. Keep area around muffler free from
any debris.
Use a soft bristle brush to loosen caked on dirt or oil.
Use a damp cloth to wipe exterior surfaces clean.
NOTICE Improper treatment of generator could damage
it and shorten its life. Do not expose generator to excessive
moisture, dust, dirt, or corrosive vapors. Do not insert any
objects through cooling slots.
Fuel Valve Maintenance
The fuel valve is equipped with a fuel sediment cup,
screen, and o-ring that need to be cleaned.
1. Move fuel valve to off (0) position.
2. Remove sediment cup from fuel valve. Remove o-ring
and screen from fuel valve.
3. Wash sediment cup, o-ring, and screen in a
nonflammable solvent. Dry them thoroughly.
4. Place screen and o-ring into fuel valve. Install
sediment cup and tighten securely.
5. Move fuel valve to on (I) position, and check for leaks.
Replace fuel valve if there is any leakage.
Battery Maintenance
Other than charging, no maintenance is required for the
starting battery. Keep the battery and terminals clean and
dry.
NOTICE Battery charging should be performed in a dry
location.
WARNING!
Battery posts, terminals and related
accessories contain lead and lead compounds -
chemicals known to the State of California to cause
cancer and reproductive harm. Wash hands after
handling.
Screen
O-Ring
Sediment Cup
First 5 Hours
Change engine oil
Every 8 Hours or Daily
Clean debris
Check engine oil level
Every 25 Hours or Yearly
Clean engine air filter
1
Every 100 Hours or Yearly
Change engine oil
1
Yearly
Replace engine air filter
1
Service fuel valve
Service spark plug
Inspect muffler and spark arrester
Not for
Reproduction
EN13
Maintenance
Engine Maintenance
Oil Recommendations
We recommend the use of Briggs & Stratton Warranty
Certified oils for best performance. Other high-quality
detergent oils are acceptable if classified for service SF
or higher. Do not use special additives. See Common
Service Parts.
Outdoor temperatures determine the proper oil viscosity for
the engine. Use the chart to select the best viscosity for the
outdoor temperature range expected.
* Below 4°C (40°F) the use of SAE 30 will result in hard starting.
** Above 27°C (80°F) the use of 10W30 may cause increased oil
consumption. Check oil level more frequently.
Checking/Adding Engine Oil
Oil level should be checked prior to each use or at least
every 8 hours of operation. Keep oil level maintained.
1. Make sure generator is on a level surface.
2. Clean area around oil fill, remove dipsitck and wipe
with clean cloth. Replace dipstick. Remove and check
oil level.
NOTICE Do not screw in dipstick when checking oil level.
3. Verify oil is at full mark on dipstick. Replace and
tighten dipstick.
4. If needed, slowly pour oil into oil fill opening to the full
mark on dipstick. Do not overfill.
NOTICE Overfilling with oil could cause the engine to not
start, or hard starting.
Do not overfill.
If over the full mark on dipstick, drain oil to reduce oil level to
full mark on dipstick.
5. Replace and tighten dipstick.
NOTICE Do not attempt to crank or start engine before
it has been properly serviced with recommended oil. This
could result in an engine failure.
CAUTION Avoid prolonged or repeated skin contact
with used motor oil. Used motor oil has been shown
to cause skin cancer in certain laboratory animals.
Thoroughly wash exposed areas with soap and water.
KEEP OUT OF REACH OF CHILDREN. DON’T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.
Changing Engine Oil
If you are using your generator under extremely dirty or
dusty conditions, or in extremely hot weather, change the
oil more often.
Change the oil while the engine is still warm from running,
as follows:
1. Make sure unit is on a level surface.
2. Remove oil drain plug and drain oil completely into a
suitable container.
3. Reinstall oil drain plug and tighten securely. Remove
dipstick.
4. Slowly pour recommended oil (about 36 oz. (1.0 l))
into oil fill opening. Pause to permit oil to settle. Fill to
Full mark on dipstick.
5. Wipe dipstick clean each time oil level is checked. Do
not overfill.
6. Reinstall dipstick. Tighten cap securely.
7. Wipe up any spilled oil.
Oil Drain Plug
Full
Not for
Reproduction
EN14 BRIGGSandSTRATTON.COM
Maintenance
Service Air Cleaner
Your engine will not run properly and may be damaged if
you run it with a dirty air cleaner. Clean or replace more
often if operating under dusty or dirty conditions.
1. Loosen screws and remove air cleaner cover.
2. Carefully remove cartridge from base.
3. Install clean (or new) air cleaner assembly inside
cover. Dispose of old filter properly.
NOTICE If the filter is excessively dirty, replace with a
new filter. See Common Service Parts.
4. Assemble air cleaner cover onto base and tighten
screws.
Service Spark Plug
Changing the spark plug will help your engine to start
easier and run better.
1. Clean area around spark plug.
2. Remove and inspect spark plug.
3. Replace spark plug if electrodes are pitted, burned
or porcelain is cracked. Use the recommended
replacement spark plug. See Common Service Parts.
4. Check electrode gap with wire feeler gauge and reset
spark plug gap to recommended gap if necessary
(see Specifications).
5. Install spark plug and tighten firmly.
Inspect Muffler and Spark Arrester
The engine exhaust muffler has a spark arrester screen.
Inspect the muffler for cracks, corrosion, or other damage.
Inspect spark arrester screen for damage or carbon
blockage. Clean if carbon blockage is found or replace if
damaged. If replacement parts are required, make sure to
use only original equipment replacement parts.
WARNING!
Contact with muffler area could
cause burns resulting in serious injury.
Do not touch hot parts.
It is a violation of California Public Resource Code,
Section 4442, to use or operate the engine on any forest-
covered, brush-covered, or grass-covered land unless
the exhaust system is equipped with a spark arrester, as
defined in Section 4442, maintained in effective working
order. Other states or federal jurisdictions may have
similar laws, reference Federal Regulation 36 CFR Part
261.52.
Clean or replace spark arrester as follows:
1. Remove four screws that connect heat shield to
muffler.
2. Remove four screws that attach spark arrester screen.
3. Obtain a replacement screen. See Common Service
Parts.
4. Reattach screen and muffler guard.
Common Service Parts
Air Cleaner ......................491588 or 5043
Spark Plug .............................491055
Engine Oil Bottle ...............100005 or 100028
Synthetic Oil Bottle ......................100074
Fuel Stabilizer .................100120 or 100117
Spark Arrester ........................ 83083GS
Contact an authorized service dealer or
BRIGGSandSTRATTON.COM for a full list of parts and
diagrams.
Screws
Cover
Filter
Base
Muffler
Heatshield
Spark Arrester Screen
Screws
Screws
Not for
Reproduction
EN15
Storage
Storage
If storing the unit for more than 30 days, use the following
guidelines to prepare it for storage.
Long Term Storage Instructions
1. Clean the generator as outlined in Cleaning.
2. Change engine oil while engine is still warm, drain oil
from crankcase. Refill with recommended grade. See
Changing Engine Oil.
3. Treat or drain fuel from generator as fuel can become
stale when stored over 30 days.
Stale fuel causes acid and gum deposits to form in the fuel
system or on essential carburetor parts. To keep fuel fresh,
use Briggs & Stratton® Advanced Formula Fuel Treatment
& Stabilizer, available wherever Briggs & Stratton genuine
service parts are sold. See Common Service Parts.
There is no need to drain gasoline from the engine if a
fuel stabilizer is added according to instructions. Run the
engine for 2 minutes to circulate the stabilizer throughout
the fuel system before storage.
If gasoline in the engine has not been treated with a fuel
stabilizer, it must be drained into an approved container.
Run the engine until it stops from lack of fuel. The use of a
fuel stabilizer in the storage container is recommended to
maintain freshness.
WARNING!
Fuel and its vapors are extremely
flammable and explosive which could cause
burns, fire or explosion resulting in death or
serious injury.
When storing fuel or equipment with fuel in tank, store
away from furnaces, stoves, water heaters, clothes dryers
or other appliances that have pilot light or other ignition
source because they could ignite fuel vapors.
When draining fuel, turn generator engine off and let it
cool at least 2 minutes before removing fuel cap. Loosen
cap slowly to relieve pressure in tank. Drain fuel tank
outdoors. Keep fuel away from sparks, open flames, pilot
lights, heat, and other ignition sources.
Check fuel lines, tank, cap and fittings frequently for
cracks or leaks. Replace if necessary.
4. Plug charger into battery charger jack and a 120 Volt
AC wall receptacle.
NOTICE The charger will not overcharge the battery
when plugged in for an extended period of time.
5. Store generator in clean, dry area and cover with a
suitable protective cover that does not retain moisture.
WARNING! Storage covers could cause a fire
resulting in death or serious injury.
Do not place a storage cover over a hot generator. Let
equipment cool for a sufficient time before placing the
cover on the equipment.
Not for
Reproduction
EN16 BRIGGSandSTRATTON.COM
Troubleshooting/Specifications
Problem Cause Correction
Engine is running, but no AC
output is available.
1. One of the circuit breakers is open.
2. Poor connection or defective cord set.
3. Connected device is bad.
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is in
good condition.
Engine runs well at no-load but
“bogs down” when loads are
connected.
1. Generator is overloaded. 1. See Generator Capacity.
Engine will not start; starts and
runs rough or shuts down when
running.
1. Start switch in OFF (0) position.
2. Fuel valve is in off (0) position.
3. Low oil level.
4. Dirty air cleaner.
5. Out of fuel.
6. Spark plug wire not connected to
spark plug.
7. Flooded with fuel.
8. Low battery charge.
1. Turn key in switch to RUN (I) position.
2. Turn fuel valve to on (I) position.
3. Fill crankcase to proper level or
place generator on level surface.
4. Clean or replace air cleaner.
5. Fill fuel tank.
6. Connect wire to spark plug.
7. Wait 5 minutes and re-crank engine.
8. Charge battery for 24 hours.
For all other issues, see a Briggs & Stratton authorized dealer.
Specifications
Model 030663A
Running Watts* ...........................7,000
Starting Watts** ...........................8,750
AC Current at 240 Volts ............... 29.1 Amps
AC Current at 120 Volts ............... 58.3 Amps
Frequency. . . . . . . . . . . . . . . . . . . . . 60 Hz at 3600 rpm
Phase ............................ Single Phase
Displacement ................25.63 cu. in. (420 cc)
Spark Plug Gap ...............0.030 in. (0.76 mm)
Fuel Capacity .........7.5 U.S. Gallons (28.4 Liters)
Oil Capacity ................36 Ounces (1.0 Liters)
Model 030664A
Running Watts* ...........................8,000
Starting Watts** ..........................10,000
AC Current at 240 Volts ............... 33.3 Amps
AC Current at 120 Volts ............... 66.6 Amps
Frequency. . . . . . . . . . . . . . . . . . . . . 60 Hz at 3600 rpm
Phase ............................ Single Phase
Displacement ................25.63 cu. in. (420 cc)
Spark Plug Gap ...............0.030 in. (0.76 mm)
Fuel Capacity .........7.5 U.S. Gallons (28.4 Liters)
Oil Capacity ................36 Ounces (1.0 Liters)
Power Ratings: The gross power rating for individual gasoline engine models is labeled in accordance with SAE (Society of Automotive
Engineers) code J1940 Small Engine Power & Torque Rating Procedure, and is rated in accordance with SAE J1995. Torque values are
derived at 2600 RPM for those engines with “rpm” called out on the label and 3060 RPM for all others; horsepower values are derived
at 3600 RPM. The gross power curves can be viewed at www.BRIGGSandSTRATTON.COM. Net power values are taken with exhaust
and air cleaner installed whereas gross power values are collected without these attachments. Actual gross engine power will be higher
than net engine power and is affected by, among other things, ambient operating conditions and engine-to-engine variability. Given the
wide array of products on which engines are placed, the gasoline engine may not develop the rated gross power when used in a given
piece of power equipment. This difference is due to a variety of factors including, but not limited to, the variety of engine components
(air cleaner, exhaust, charging, cooling, carburetor, fuel pump, etc.), application limitations, ambient operating conditions (temperature,
humidity, altitude), and engine-to engine variability. Due to manufacturing and capacity limitations, Briggs & Stratton may substitute an
engine of higher rated power for this engine.
* Generator certified in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-14, Motors and Generators
and PGMA (Portable Generator Manufacturers’ Association) standard ANSI/PGMA G300-2015, Safety and Performance of Portable
Generators.
** Per Briggs & Stratton 628K
Not for
Reproduction
EN17
Troubleshooting
Schematic - Model 030663A (7000 Watt)
Not for
Reproduction
EN18 BRIGGSandSTRATTON.COM
Troubleshooting
Schematic - Model 030664 (8000 Watt)
Not for
Reproduction
EN19
Notes
Not for
Reproduction
EN20 BRIGGSandSTRATTON.COM
Warranty
80011056_EN Rev A
BRIGGS & STRATTON PRODUCTS WARRANTY POLICY
LIMITED WARRANTY
Briggs & Stratton warrants that, during the warranty period specified below, it will repair or replace, free of charge, any part that is defective in material or workmanship
or both. Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser. This warranty is effective for
and is subject to the time periods and conditions stated below. For warranty service, find the nearest Authorized Service Dealer in our dealer locator map at
BRIGGSandSTATTON.COM. The purchaser must contact the Authorized Service Dealer, and then make the product available to the Authorized Service Dealer for
inspection and testing.
There is no other express warranty. Implied warranties, including those of merchantability and fitness for a particular purpose, are limited to the
warranty period listed below, or to the extent permitted by law. Liability for incidental or consequential damages are excluded to the extent exclusion
is permitted by law. Some states or countries do not allow limitations on how long an implied warranty lasts, and some states or countries do not allow the exclusion
or limitation of incidental or consequential damages, so the above limitation and exclusion may not apply to you. This warranty gives you specific legal rights and you
may also have other rights which vary from state to state or country to country.**
WARRANTY PERIOD
After 12 months, warranty covers parts only.
* Applies to Briggs & Stratton engines only. Warranty coverage of non-Briggs & Stratton engines is provided by that engine manufacturer. Emissions-related components
are covered by the Emissions Warranty Statement.
** In Australia - Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major
failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be
of acceptable quality and the failure does not amount to a major failure. For warranty service, find the nearest Authorized Service Dealer in our dealer locator map at
BRIGGSandSTRATTON.COM, or by calling 1300 274 447, or by emailing or writing to [email protected], Briggs & Stratton Australia Pty Ltd, 1
Moorebank Avenue, NSW, Australia, 2170.
The warranty period begins on the date of purchase by the first retail or commercial consumer. “Consumer use” means personal residential household use by a retail
consumer. “Commercial use” means all other uses, including use for commercial, income producing or rental purposes. Once a product has experienced commercial
use, it shall thereafter be considered as a commercial use product for purposes of this warranty.
Save your proof of purchase receipt. If you do not provide proof of the initial purchase date at the time warranty service is requested, the manufacturing date of the
product will be used to determine the warranty period. Product registration is not required to obtain warranty service on Briggs & Stratton products.
ABOUT YOUR WARRANTY
Warranty service is available only through Briggs & Stratton Authorized Service Dealers. This warranty covers only defects in materials or workmanship. It does not cover
damage caused by improper use or abuse, improper maintenance or repair, normal wear and tear, or stale or unapproved fuel.
Improper Use and Abuse - The proper, intended use of this product is described in the Operator’s Manual. Using the product in a way not described in the Operator’s
Manual or using the product after it has been damaged will not be covered under this warranty. Warranty coverage will also not be provided if the serial number on the
product has been removed or the product has been altered or modified in any way, or if the product has evidence of abuse such as impact damage or water/chemical
corrosion damage.
Improper Maintenance or Repair - This product must be maintained according to the procedures and schedules provided in the Operator’s Manual, and serviced or
repaired using genuine Briggs & Stratton parts or equivalent. Damage caused by lack of maintenance or use of non-original parts is not covered by warranty.
Normal Wear and Tear - Like most mechanical devices, your unit is subject to wear even when properly maintained. This warranty does not cover repairs when normal
use has exhausted the life of a part or the equipment. Maintenance and wear items such as filters, belts, cutting blades, and brake pads (except engine brake pads) are
not covered by warranty due to wear characteristics alone, unless the cause is due to defects in material or workmanship.
Stale or Unapproved Fuel - In order to function correctly, this product requires fresh fuel that conforms to the criteria specified in the Operator’s Manual. Engine or
equipment damage caused by stale fuel or the use of unapproved fuels (such as E15 or E85 ethanol blends) is not covered by warranty.
Other Exclusions - This warranty excludes damage due to accident, abuse, modifications, alterations, improper servicing, freezing or chemical deterioration.
Attachments or accessories that were not originally packaged with the product are also excluded. There is no warranty coverage on equipment used for primary power in
place of utility power or on equipment used in life support applications. This warranty does not include used, reconditioned, second-hand, or demonstration equipment or
engines. This warranty also excludes failures due to acts of God and other force majeure events beyond the manufacturer’s control.
Item Consumer Use Commercial Use
Equipment 36 months 12 months
Engine* 24 months 12 months
Battery (if equipped) 3 months None
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Simplicity 030664A-00 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur

dans d''autres langues