KitchenAid KVUC600JSS Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation

Ce manuel convient également à

30" (76.2 CM) AND 36" (91.4 CM)
COMMERCIAL STYLE
WALL-MOUNT CANOPY RANGE HOOD
Installation Instructions and Use & Care Guide
For questions about features, operation/performance, parts, accessories or service, call: 1-800-422-1230
or visit our website at www.kitchenaid.com
In Canada, for assistance, installation and service, call: 1-800-807-6777
or visit our website at www.kitchenaid.ca
HOTTE D'EXTRACTION À MONTAGE MURAL
DE STYLE COMMERCIAL DE
30" (76,2 CM) ET 36" (91,4 CM)
Instructions dinstallation et Guide dutilisation et dentretien
Au Canada, pour assistance, installation ou service composez le 1-800-807-6777
ou visitez notre site web à www.kitchenaid.ca
Table of Contents/Table des matières.............................................................................2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
LI3Y4B/W11374534A
2
TABLE OF CONTENTS
RANGE HOOD SAFETY .................................................................2
INSTALLATION REQUIREMENTS................................................4
Tools and Parts ............................................................................4
Location Requirements................................................................4
Venting Requirements..................................................................5
Electrical Requirements ...............................................................6
INSTALLATION INSTRUCTIONS..................................................7
Prepare Location..........................................................................7
Install Range Hood.......................................................................9
Make Electrical Connection .........................................................9
Install Vent Covers (Optional).....................................................10
Complete Installation .................................................................10
RANGE HOOD USE......................................................................10
Range H
ood Controls ................................................................10
RANGE HOOD CARE...................................................................11
Cleaning......................................................................................11
WIRING DIAGRAM ......................................................................12
ASSISTANCE OR SERVICE.........................................................13
In the U.S.A. ...............................................................................13
Accessories ................................................................................13
In Canada ...................................................................................13
TABLE DES MATIÈRES
CURITÉ DE LA HOTTE DE CUISINIÈRE ...............................15
EXIGENCES D'INSTALLATION...................................................17
Outils et pièces...........................................................................17
Exigences d’emplacement.........................................................17
Exigences concernant l’évacuation ...........................................18
Spécifications électriques ..........................................................20
INSTRUCTIONS D'INSTALLATION.............................................20
Préparation de l'emplacement...................................................20
Installation de la hotte ................................................................22
Raccordement électrique...........................................................23
Installation des cache-conduits (facultatif) ................................24
Achever l’installation ...................................................
...............24
UTILISATION DE LA HOTTE .......................................................24
Commandes de la hotte de cuisinière .......................................24
ENTRETIEN DE LA HOTTE..........................................................25
Nettoyage ...................................................................................25
SCHÉMA DE CÂBLAGE ..............................................................26
ASSISTANCE OU SERVICE.........................................................27
Au Canada..................................................................................27
Accessoires ................................................................................27
RANGE HOOD SAFETY
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
3
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag,
to the service panel.
Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.
Do not operate any fan with a damaged cord or plug.
Discard fan or return to an authorized service facility for
examination and/or repair.
Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), the American Society for
Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling; do not damage
electrical wiring and other utilities.
Ducted fans must always be vented outdoors.
CAUTION: For general ventilating use only. Do not use
to exhaust hazardous or explosive materials and vapors.
CAUTION: To reduce risk of fire and to properly exhaust
air, be sure to duct air outside - do not vent exhaust air into
spaces within walls or ceilings, attics or into crawl spaces,
or garages.
WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
WARNING: TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE:
Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
Always turn hood ON when cooking at high heat or when
flambeing food (i.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING: TO REDUCE THE RISK OF INJURY TO
PERSONS IN THE EVENT OF A RANGE TOP GREASE
FIRE, OBSERVE THE FOLLOWING:
a
SMOTHER FLAMES with a close fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out
immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
NEVER PICK UP A FLAMING PAN - you may be burned.
DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
Use an extinguisher ONLY if:
– You know you have a class ABC extinguisher, and you
already know how to operate it.
– The fire is small and contained in the area where it
started.
– The fire department is being called.
– You can fight the fire with your back to an exit.
a
Based on "Kitchen Fire Safety Tips" published by NFPA.
WARNING: To reduce the risk of fire or electrical shock,
do not use this fan with any solid-state speed control
device.
4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Level
Drill with 1¼" (3.0 cm), ³⁄₁₆" (4.8 mm), ¹⁄₈" (3.0 mm), and
⁵⁄₁₆" (7.9 mm) drill bits
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Metric hex key set
Parts needed
Home power supply cable
½" (12.7 mm) UL listed or CSA approved strain relief
3 UL listed wire connectors
1 wall or roof cap
Metal vent system
Parts supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and light bulbs
installed
3¼" x 10" (8.3 x 25.4 cm) rectangular vent connector
2 metal grease filters for 30" (76.2 cm) model
3 metal grease filters for 36" (91.4 cm) model
T20 Torx
®†
adapter
4 - 5 x 45 mm mounting screws
6 - 4.5 x 13 mm screws
3 - 4 x 8 mm screws
4 - 10 x 50 wall anchors
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial rating
plate is located behind the left filter on the rear wall of the vent
hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
The canopy hood is factory set for venting through the roof or
wall.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
Product Dimensions
Front View
†®TORX is a registered trademark of Saturn Fasteners, Inc.
12"
(30.5 cm)
3¹⁄₈"
(7.9 cm)
30" (76.2 cm)
36" (91.4 cm)
23" (58.4 cm)
10"
(25.4 cm)
³⁄₈"
(1.0 cm)
2⁹⁄₁₆"
(6.5 cm)
7½"
(19.0 cm)
29¹⁄₈" (74.0 cm): 30" (76.2 cm) models
35¹⁄₈" (89.2 cm): 36" (91.4 cm) models
5
Back View
Cabinet Dimensions
IMPORTANT:
Minimum distance “X” : 24" (61.0 cm) to electric cooking surface
and 30" (76.2 cm) to gas cooking surface.
Suggested maximum distance “X” : 36" (91.4 cm)
Venting Requirements
Vent system must terminate to the outdoors.
Do not terminate the vent system in an attic or other enclosed
area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Use metal vent only. Rigid metal vent is recommended.
The length of vent system and number of elbows should be
kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper. If roof or wall cap has a
damper, do not use damper supplied with the range hood.
Use caulking to seal exterior wall or roof opening around the
cap.
The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed to
minimize conduction of outside temperatures as part of the vent
system. The damper should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
Venting Methods
This canopy hood is factory set for venting through the roof or
wall.
A 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vent system is needed for
installation (not included). The hood exhaust opening is 3¹⁄₄"x
10" (8.3 x 25.4 cm). Vent system can terminate either through the
roof or wall. To vent out of the top of the range hood and through
a wall, a 90° elbow is needed. See “Install Range Hood” section
for details for installing the damper.
NOTE: Flexible vent is not recommended. Flexible vent creates
back pressure and air turbulence that gently reduce performance.
A. For installations with canopy
only. 70" (177.8 cm) minimum
above electric cooking surface.
76" (193.0 cm) minimum above
gas cooking surface.
B. For installations with optional
duct cover. 82" (208.3 cm)
minimum above electric
cooking surface. 88"
(223.5 cm) minimum above
gas cooking surface.
1¹⁄₈"
(2.9 cm)
7" (17.8 cm): 30" (76.2 cm) models
9⁷⁄₈" (25.0 cm): 36" (91.4 cm) models
Wiring knockout
7⁷⁄₈"
(20.0 cm)
30" (76.2 cm) models: 12¼" (31.1 cm)
36" (91.4 cm) models: 15" (38.1 cm)
12³⁄₁₆" (31.0 cm)
⁵⁄₈"
(1.6 cm)
13" (33.0 cm)
18" (45.7 cm) min.
clearance upper
cabinet to countertop
36" (91.4 cm)
countertop height
30" (76.2 cm) or 36" (91.4 cm)
cabinet opening width
(If installed between cabinets)
A
B
X
Bottom of canopy
to cooking surface
Min. cabinet
opening width
Duct cover (if used)
Canopy
6
Rear discharge
This range hood can be vented directly out the back using the
3¼" x 10" (8.3 cm x 25.4 cm) rectangular damper (supplied) along
with a 3¼" x 10" (8.3 cm x 25.4 cm) rectangular vent system (not
supplied). See “Install Range Hood” section for details for
installing the damper.
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) Vent System
Example vent system
Electrical Requirements
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 (latest
edition), or CSA Standards C22.1-94, Canadian Electrical Code,
Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes
and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is
required.
If the house has aluminum wiring, follow the procedure
below:
1. Connect a section of solid copper wire to the pigtail
leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of
the appliance as specified on the model/serial rating plate.
The model/serial plate is located behind the filter on the rear
wall of the range hood.
Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22. 1-94, Canadian Electrical Code, Part 1 and
C22.2 No. 0-M91 (latest edition) and all local codes and
ordinances.
Roof Venting Wall Venting
(top or rear discharge)
A. Roof cap
B. 3
¹⁄₄
" x 10" (8.3 x 25.4 cm)
rectangular metal vent
A. Wall cap
B. 3
¹⁄₄
" x 10" (8.3 x 25.4 cm)
rectangular metal vent
Vent Piece
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
90° elbow
5.0 ft
(1.5 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
flat elbow
12.0 ft
(3.7 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
wall cap
0.0 ft
(0.0 m)
A
B
A
B
Maximum Recommended Length = 35 ft (10.7 m)
1 - 90° elbow = 5.0 ft (1.5 m)
8 ft (2.4 m) straight = 8.0 ft (2.4 m)
1 - wall cap = 0.0 ft (0.0 m)
Length of 3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
system
= 13.0 ft (3.9 m)
Wall cap
3
¹⁄₄" x 10"
(8.3 x 25.4 cm)
elbow
2 ft
(0.6 m)
6 ft (1.8 m)
7
INSTALLATION INSTRUCTIONS
Prepare Location
It is recommended that the vent system be installed before
hood is installed.
If you are installing a full width duct cover, follow the
instructions included with that product.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
Check your ceiling height and the hood height maximum
before you select your hood.
1. Disconnect power.
2. Determine which venting method to use: roof or wall.
3. Select a flat surface for assembling the range hood. Place
covering over that surface.
4. Using 2 or more people, lift range hood onto covered surface.
NOTE: This range hood can be mounted to the cabinets or to the
wall.
For Cabinet Installations
1. If cabinet has recessed bottom, add wood filler strips on each
side. Install screws to attach filler strips in locations shown.
Determine Wiring Hole Location
Cut only one 1¹⁄₄" (3.2 cm) diameter wiring access hole. See
Step 2 for wiring hole location instructions.
1. Determine and clearly mark a vertical centerline on the wall
and cabinet in the area the vent opening will be made.
2. To wire through top:
Mark a line distance “A” from the left of the centerline on the
underside of the cabinet. Mark the point on this line that is
7⁷⁄₈" (20.0 cm) from back wall. Drill a 1¼" (3.2 cm) diameter
hole through the cabinet at this point.
Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm)
Rectangular Vent System
Roof Venting
To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangular cutout
on the underside of cabinet top and bottom:
1. Mark lines ¹⁄₂" (1.3 cm) and 4¹⁄₂" (11.4 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
Cabinet
bottom
Wall
3" (7.6 cm)
Wood filler strips
(recessed cabinet
bottoms only)
3" (7.6 cm)
A. Centerline
A. 12
³⁄₁₆
" (31.0 cm)
A
Centerline
7⁷⁄₈" (20.0 cm
)
from wall,
not cabinet
frame
A
8
4. Repeat steps 1-3 for the underside of the top of the cabinet.
Wall Venting Under Cabinet
To make a 3½" x 10½" (8.9 cm x 26.7 cm) rectangle in the
wall:
1. Make 2 lines by measuring ³⁄₈" (9.5 mm) and 3⁷⁄₈" (9.8 cm)
down from underside of cabinet and mark on the centerline
on the back wall.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the wall.
Use saber or keyhole saw to cut a rectangular opening in the wall
for the vent.
3. Lift the range hood up under cabinet and determine final
location by centering beneath cabinet. Mark on the underside
of cabinet the location of the 4 keyhole mounting slots on the
range hood. Set range hood aside on a covered surface.
4. Use ¹⁄₈" (3 mm) drill bit and drill 4 pilot holes as shown.
5. Install the 4 - 4.5 x 13 mm mounting screws in pilot holes.
Leave about ¹⁄₄" (6.4 cm) space between screw heads and
cabinet to slide range hood into place.
For Wall Installations:
1. Determine and mark the centerline on the wall where the
canopy hood will be installed.
2. Select a mounting height between a minimum of
24" (61.0 cm) for electric cooking surfaces and 30" (76.2 cm)
for gas cooking surfaces. The suggested maximum height is
36" (91.4 cm) above the range to the bottom of the hood.
Mark a horizontal reference line on the wall.
3. Using 2 or more people, center the hood on the vertical
centerline, then align the bottom of the hood with the
horizontal reference line marked on the wall.
4. Mark centers of the fastener locations to the wall. Set range
hood aside on a covered surface.
IMPORTANT: All screws must be installed into wood. If there
is no wood to screw into, additional wall framing supports
may be required.
5. Drill ³⁄₁₆" (4.8 mm) pilot holes at all locations where screws are
being installed into wood.
6. Install the 2 - 5 x 45 mm mounting screws. Leave a
¹⁄₄" (6.4 mm) gap between the wall and the back of the
screw head to slide range hood into place.
7. Determine and make all necessary cuts in the wall or ceiling
for the vent system. Install the vent system before installing
the hood. See “Venting Requirements” section.
A. Keyhole slot
A. Drill pilot hole.
5¹/"
(13.3 cm)
5¹/"
(13.3 cm)
*4¹⁄₂"
(11.4 cm)
*From wall, not cabinet frame
Cabinet cutouts
*¹⁄₂" (1.3 cm)
³⁄₈"
3 ⁷⁄₈"
Cabinet
front
5
¹⁄₄"
(9.5 mm)
(9.8 cm)
(13.3 cm)
Centerline
A
A
¹⁄₄"
(6.4 mm)
A. Horizontal reference line
B. Vertical centerline
C. Mounting height
D. Cooking surface
A. Keyhole slot
A. Drill pilot hole.
A
C
B
X
D
A
A
¹⁄₄"
(6.4 mm)
9
Complete Preparation
1. Determine the required height for the home power supply
cable and drill a 1¼" (3.2 cm) hole at this location.
2. Run the home power supply cable according to the National
Electrical Code or CSA Standards and local codes and
ordinances. There must be enough ½" conduit and wires from
the fused disconnect (or circuit breaker) box to make the
connection in the hood’s electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
3. Remove the grease filters. See the “Range Hood Care”
section.
4. Remove terminal box cover and set aside.
5. Remove knockout from the top of the vent hood and install a
UL listed or CSA approved ½" strain relief.
Install Range Hood
1. Depending on your installation, remove either top or rear
rectangular vent knockout.
2. Remove tape from damper flap.
NOTE: The 3¼" x 10" (8.3 x 25.4 cm) rectangular damper can
be installed up to 1" (2.5 cm) on either side of the hood center
to accommodate off center duct work.
3. Attach the 3¼" x 10" (8.3 x 25.4 cm) rectangular vent
connector to the range hood using sheet metal screws.
NOTE: If the wall cap is directly behind the 3¼" x 10"
(8.3 x 25.4 cm) rectangular vent connector, check that the
damper and the wall cap do not interfere with each other.
Remove the damper from the 3¼" x 10" ( 8.3 x 25.4 cm)
rectangular vent connector if they interfere.
4. Using 2 or more people, lift the hood into final position. Feed
enough electrical wire through the ½" UL listed or CSA
approved strain relief to make connections in the terminal
box. Tighten the strain relief screws.
5. Position the range hood so that the large end of the keyhole
slots are over the mounting screws. Then push the hood
toward the wall (for cabinet mounting) or allow the range
hood to slide down to the marked mounting height (for wall
mounting) so that the screws are in the neck of the slots.
Tighten the mounting screws, making sure the screws are in
the narrow neck of slots. (For wall mount, check that the
hood is level).
6. Connect ventwork to hood. Seal joints with clamps to make
secure and airtight.
7. Check that back draft dampers work properly.
Make Electrical Connection
1. Disconnect power.
2. Use UL listed wire connectors and connect white wires (A)
together.
A. Vent knockouts
A. Top venting
B. Sheet metal screws
C. Hinge pin
D. Vent knockouts
E. Rear venting
A
A
B
C
D
C
B
E
A. White wires
B. Black wires
C. UL listed wire connector
D. Green (or bare) and yellow-green ground wire
E. Home power supply cable
F. UL listed or CSA approved ½" strain relief
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
C
D
E
F
10
3. Use UL listed wire connectors and connect black wires (B)
together.
4. Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (C) in terminal box using UL
listed wire connectors.
5. Install terminal box cover.
6. Check that all light bulbs are secure in their sockets.
7. Reconnect power.
Install Vent Covers (Optional)
If you are installing an optional full width duct cover, follow the
instructions included with that product.
Complete Installation
1. Install metal grease filters. See the “Range Hood Care”
section.
2. Check the operation of the range hood blower and light. See
the “Range Hood Use” section.
NOTE: To get the most efficient use from your new range hood,
read the “Range Hood Use” section.
RANGE HOOD USE
The range hood is designed to remove smoke, cooking vapors
and odors from the cooktop area. For best results, start the hood
before cooking and allow it to operate several minutes after the
cooking is complete to clear all smoke and odors from the
kitchen.
The hood controls are located on the underside of the range
hood.
Range Hood Controls
Operating the light
1. Move the light switch to the “1” position to turn range hood
light to night light setting.
2. Move the light switch to the “2” position to turn range hood
light to full light setting.
3. Move the light switch to the “Off” position to turn range hood
light OFF.
Operating the fan
1. Move the fan switch to the “On” position to turn the fan ON.
The fan will begin operating at the speed set on the fan speed
switch.
2. Move the fan switch to the “Off” position to turn the fan OFF.
Auto On Fan
The range hood is equipped with a sensor to automatically turn
on the fan when excessive heat is detected in the control area.
When the fan switch is in the “Off” position, this sensor will turn
the fan to high speed when necessary. When the heat decreases,
the fan will turn off.
When the fan switch is in theOn position, the heat sensor is not
active and the range hood functions normally.
Adjusting the fan
The fan has 3 speed controls. Move the fan speed switch to “1”
position for low speed, “2” position for medium speed, or “3”
position for high speed.
Thermal Protector
The range hood is equipped with a thermal protector to avoid
overheating conditions. If the range hood shuts off while in use,
move fan slider switch to Off to turn off the range hood. Wait
approximately 60 minutes, then move slider to On to restart the
range hood.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
A. Light control
B. Blower control
C. Fan speed control
A
B
C
11
RANGE HOOD CARE
Cleaning
IMPORTANT: Clean the hood and grease filters frequently
according to the following instructions. Replace grease filters
before operating hood.
Exterior Surfaces:
To avoid damage to the exterior surface, do not use steel wool or
soap-filled scouring pads.
Always wipe dry to avoid water marks.
Cleaning Method:
Liquid detergent soap and water, or all-purpose cleanser
Wipe with damp soft cloth or nonabrasive sponge, then rinse
with clean water and wipe dry.
Metal Grease Filter
To Remove Metal Grease Filters:
1. Use 2 hands to remove the metal grease filters. Grasp filter
handles, push toward the rear of the range hood and pull
down on the front handle to remove.
2. Repeat for each grease filter.
3. Wash metal grease filters as needed in a dishwasher or hand
wash in a hot detergent solution to clean.
To Reinstall Metal Grease Filters:
1. Grasp filter handles and place rear of filter into rear track.
2. Push down on the rear handle and se
t the front of the grease
filter into the front track to secure.
3. Repeat for each filter.
Replacing a LED Lamp
Turn off the range hood and allow the LED lamp to cool. To
avoid damage or decreasing the life of the new bulb, do not
touch bulb with bare fingers. Replace bulb, using tissue or
wearing cotton gloves to handle bulb.
If new lamps do not operate, make sure the lamps are inserted
correctly before calling service.
1. Disconnect power.
2. Push up on the lens and turn it counterclockwise.
3. Remove the bulb and replace it with a 120-volt, 6.5-watt
maximum
LED bulb with a GU10 base. Turn it clockwise
to lock it into place.
4. Repeat steps 2-3 for the other bulb if needed.
5. Reconnect power.
12
WIRING DIAGRAM
LED LED
SE11RB
Junction Box
Motor Resistance
(Ohms)
Blue - Red
Blue - Gray
Blue - Black
Blue - White
Room Temp.
18
14.3
9.8 (max)
21.6 (min)
41˚F (23˚C)
Motor
Characteristics
Power Supply
Frequency
Power Absorption
Current
120 VAC
60 HZ
420 W
3.7A
GND
L
N
Y/G
BK
W
BR
W
W
W
W
Y
Y
BU
BR
BK
BK
R R
Y
Fan Speed
Fan
Light
On Off
Off
GY
R
W
BK
BR
Y
BK
Y
BR
BR
T
Speed 3
Speed 2
Speed 1
BK
GY
BU
W
Y
BR
Y/G
Y/G
BR
Y
W
R
BK
GY
BU
25uF
M
S50
13
ASSISTANCE OR SERVICE
When calling for assistance or service, please know the purchase
date and the complete model and serial number of your
appliance. This information will help us to better respond to your
request.
If you need replacement parts
If you need to order replacement parts, we recommend that you
use only factory specified parts. Factory specified parts will fit
right and work right because they are made with the same
precision used to build every new appliance. To l
ocate factory
specified replacement parts in your area, call us or your nearest
designated service center.
In the U.S.A.
Call the KitchenAid Customer eXperience Center toll free:
1-800-422-1230.
Our consultants provide assistance with:
Features and specifications on our full line of appliances.
Installation information.
Use and maintenance procedures.
Accessory and repair parts sales.
Specialized customer assistance (Spanish speaking, hearing
impaired, limited vision, etc.).
Referrals to local dealers, repair parts distributors and service
companies. KitchenAid designated service technicians are
trained to fulfill the product warranty and provide after-
warranty service, anywhere in the United States.
To locate the KitchenAid designated service company in your
area, you can also look in your telephone directory Yellow
Pages.
For further assistance
If you need further assistance, you can write to KitchenAid with
any questions or concerns at:
Kitch
enAid Brand Home Appliances
Customer eXperience Center
553 Benson Road
Benton Harbor, MI 49022-2692
Please include a daytime phone number in your correspondence.
Accessories
Full Width Chimney Cover
Order Part Number EXTKIT02ES for 30" (76.2 cm) model
Order Part Number EXTKIT04ES for 36" (91.4 cm) model
In Canada
Call the KitchenAid Canada Customer eXperience Centre toll
free: 1-800-807-6777.
Our consultants provide assistance with:
Features and specifications on our full line of appliances.
Use and maintenance procedures.
Accessory and repair parts sales.
Referrals to local dealers, repair parts distributors and service
companies. KitchenAid Canada designated service
technicians are trained to fulfill the product warranty and
provide after-warranty service, anywhere in Canada.
For further assistance
If you need further assistance, you can write to KitchenAid
Canada with any questions or concerns at:
Customer eXperience Centre
KitchenAid Canada
200 - 6750 Century Ave.
Mississauga, Ontario L5N 0B7
Plea
se include a daytime phone number in your correspondence.
14
15
SÉCURITÉ DE LA HOTTE DE CUISINIÈRE
Risque possible de décès ou de blessure grave si vous ne
suivez pas immédiatement les instructions.
Risque possible de décès ou de blessure grave si vous
ne suivez pas les instructions.
Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et
ce qui peut se produire en cas de non-respect des instructions.
Votre sécurité et celle des autres est très importante.
Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de
toujours lire tous les messages de sécurité et de vous y conformer.
AVERTISSEMENT
DANGER
Voici le symbole d’alerte de sécurité.
Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous
et à d’autres.
Tous les messages de sécurité suivront le symbole d’alerte de sécurité et le mot “DANGER” ou
“AVERTISSEMENT”. Ces mots signifient :
16
IMPORTANTES INSTRUCTIONS DE SÉCURITÉ
LIRE ET CONSERVER CES INSTRUCTIONS
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE
D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES
CORPORELS, RESPECTER LES INSTRUCTIONS
SUIVANTES :
Utiliser cet appareil uniquement dans les applications
envisagées par le fabricant. Pour toute question, contacter
le fabricant.
Avant d'entreprendre un travail d'entretien ou de nettoyage,
interrompre l'alimentation de la hotte au niveau du tableau
de disjoncteurs, et verrouiller le tableau de disjoncteurs
pour empêcher tout rétablissement accidentel de
l'alimentation du circuit. Lorsqu'il n'est pas possible de
verrouiller le tableau de disjoncteurs, placer sur le tableau
de disjoncteurs une étiquette d'avertissement proéminente
interdisant le rétablissement de l'alimentation.
Tout travail d'installation ou câblage électrique doit être
réalisé par une personne qualifiée, dans le respect des
prescriptions de tous les codes et normes applicables, y
compris les codes du bâtiment et de protection contre les
incendies.
Ne pas faire fonctionner un ventilateur dont le cordon ou la
fiche est endommagé(e). Jeter le ventilateur ou le retourner
à un centre de service agréé pour examen et/ou réparation.
Une source d'air de débit suffisant est nécessaire pour le
fonctionnement correct de tout appareil à gaz (combustion
et évacuation des gaz à combustion par la cheminée), pour
qu'il n'y ait pas de reflux des gaz de combustion. Respecter
les directives du fabricant de l'équipement de chauffage et
les prescriptions des normes de sécurité - comme celles
publiées par la National Fire Protection Association (NFPA)
et l'American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), et les prescriptions des
autorités réglementaires locales.
Lors d'opérations de découpage et de perçage dans un mur
ou un plafond, veiller à ne pas endommager les câblages
électriques ou canalisations qui peuvent s'y trouver.
Les ventilateurs d'évacuation doivent toujours décharger
l'air à l'extérieur.
MISE EN GARDE : Cet appareil est conçu uniquement
pour la ventilation générale. Ne pas l'utiliser pour l'extraction
de matières ou vapeurs dangereuses ou explosives.
MISE EN GARDE : Pour minimiser le risque d'incendie
et évacuer adéquatement les gaz, veiller à acheminer l'air
aspiré par un conduit jusqu'à l'extérieur - ne pas décharger
l'air aspiré dans un espace vide du bâtiment comme une
cavité murale, un plafond, un grenier, un vide sanitaire ou
un garage.
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE
D'INCENDIE, UTILISER UNIQUEMENT DES CONDUITS
MÉTALLIQUES.
AVERTISSEMENT : POUR MINIMISER LE RISQUE
D'UN FEU DE GRAISSE SUR LA CUISINIÈRE :
Ne jamais laisser un élément de surface fonctionner à
puissance de chauffage maximale sans surveillance. Un
renversement/débordement de matière graisseuse pourrait
provoquer une inflammation et la génération de fumée.
Utiliser une puissance de chauffage moyenne ou basse
pour le chauffage d'huile.
Veiller à toujours faire fonctionner le ventilateur de la hotte
lors de la cuisson avec une puissance de chauffage élevée
ou lors de la cuisson d'un mets à flamber (à savoir crêpes
Suzette, cerise jubilée, steak au poivre flambé).
Nettoyer fréquemment les ventilateurs d'extraction. Veiller à
ne pas laisser la graisse s'accumuler sur les surfaces du
ventilateur ou des filtres.
Utiliser toujours un ustensile de taille appropriée. Utiliser
toujours un ustensile adapté à la taille de l'élément
chauffant.
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE DE
DOMMAGES CORPORELS APRÈS LE DÉCLENCHEMENT
D'UN FEU DE GRAISSE SUR LA CUISINIÈRE, APPLIQUER
LES RECOMMANDATIONS SUIVANTES :
a
Placer sur le récipient un couvercle bien ajusté, une tôle à
biscuits ou un plateau métallique POUR ÉTOUFFER LES
FLAMMES, puis éteindre le brûleur. VEILLER À ÉVITER
LES BRÛLURES. Si les flammes ne s'éteignent pas
immédiatement, ÉVACUER LA PIÈCE ET APPELER LES
POMPIERS.
NE JAMAIS PRENDRE EN MAIN UN RÉCIPIENT
ENFLAMMÉ - vous risquez de vous brûler.
NE PAS UTILISER D'EAU, ni un torchon humide - ceci
pourrait provoquer une explosion de vapeur brûlante.
Utiliser un extincteur SEULEMENT si :
– Il s'agit d'un extincteur de classe ABC, dont on connaît le
fonctionnement.
– Il s'agit d'un petit feu encore limité à l'endroit où il s'est
déclaré.
– Les pompiers ont été contactés.
– Il est possible de garder le dos orienté vers une sortie
pendant l'opération de lutte contre le feu.
a
Recommandations tirées des conseils de sécurité en cas
d'incendie de cuisine publiés par la NFPA.
AVERTISSEMENT : Pour réduire le risque d'incendie
ou de choc électrique, ne pas utiliser ce ventilateur avec un
quelconque dispositif de réglage de la vitesse à semi-
conducteurs.
17
EXIGENCES D'INSTALLATION
Outils et pièces
Rassembler les outils et pièces nécessaires avant d’entreprendre
l’installation. Lire et observer les instructions fournies avec
chacun des outils de la liste ci-dessous.
Outils nécessaires
Niveau
Perceuse avec des forets 1¼" (3 cm), ³⁄₁₆" (4,8 mm),
¹⁄₈" (3 mm) et ⁵⁄₁₆" (7,9 mm)
Crayon
Pince à dénuder ou couteau utilitaire
Mètre-ruban ou règle
Pince
Pistolet à calfeutrage et composé de calfeutrage résistant
aux intempéries
Brides de conduit d’evacuation
Scie sauteuse ou scie à guichet
Tournevis à lame plate
Cisaille de ferblantier
Tournevis Phillips
Ensemble de clés à tête hexagonale (système métrique)
Pièces nécessaires
Câble d'alimentation électrique du domicile
Serre-câble de ½" (12,7 mm) (homologation UL ou CSA)
3 connecteurs de fils homologués UL
1 bouche de décharge (décharge à travers le mur ou à travers
le toit)
Circuit d’évacuation métallique
Pièces fournies
Retirer les pièces de leur emballage. Vérifier que toutes les
pièces sont présentes.
Auvent de hotte avec ventilateur et lampes installés
Connecteur 3¼" x 10" (8,3 x 25,4 cm) pour conduit
rectangulaire
2 filtres à graisse métalliques, pour modèle de 30" (76,2 cm)
3 filtres à graisse métalliques, pour modèle de 36" (91,4 cm)
Raccord d'adaptation Torx
®†
T20
4 vis de montage de 5 x 45 mm
6 vis de 4,5 x 13 mm
3 vis de 4 x 8 mm
4 chevilles d'ancrage mural de 10 x 50 mm
Exigences d’emplacement
IMPORTANT : Observer les dispositions de tous les codes et
règlements en vigueur.
Confier l'installation de la hotte à un technicien qualifié. C'est à
l'installateur qu'incombe la responsabilité de respecter les
distances de séparation spécifiées sur la plaque signalétique de
l'appareil. La plaque signalétique de l'appareil est située derrière
le filtre de gauche, sur la paroi arrière de la hotte.
On doit toujours installer la hotte à distance des sources de
courant d’air (fenêtres, portes et bouches de chauffage).
Respecter les dimensions indiquées pour les ouvertures à
découper dans les placards. Ces dimensions tiennent compte
des valeurs minimales des dégagements de séparation.
On doit disposer d'une prise de courant électrique reliée à la
terre. Voir la section “Spécifications électriques”.
La hotte est configurée à l’usine pour une décharge à travers le
toit ou un mur.
On doit assurer l’étanchéité au niveau de chaque ouverture
découpée dans le plafond ou un mur traversé par l’équipement
de la hotte.
Installation dans une résidence mobile
L’installation de cette hotte doit satisfaire aux exigences de la
norme Manufactured Home Construction Safety Standards, Titre
24 CFR, partie 328 (anciennement Federal Standard for Mobile
Home Construction and Safety, titre 24, HUD, partie 280); lorsque
cette norme n’est pas applicable, l’installation doit satisfaire aux
critères de la plus récente édition de la norme Manufactured
Home Installation 1982 (Manufactured Home Sites, Communities
and Setups) ANSI A225.1/NFPA 501A, ou des codes locaux.
†®TORX est une marque déposée de Saturn Fasteners, Inc.
18
Dimensions du produit
Vue de face
Vue arrière
Dimensions du placard
IMPORTANT :
Valeur minimale de la distance “X” : 24" (61,0 cm) jusqu'à la
surface de cuisson électrique et 30" (76,2 cm) jusqu'à la surface
de cuisson à gaz.
Valeur maximale suggérée pour la distance “X” : 36" (91,4 cm)
Exigences concernant l’évacuation
Le système doit décharger l'air à l'extérieur.
Ne pas terminer le circuit d’évacuation dans un grenier ou
dans un autre espace clos.
Ne pas utiliser une bouche de décharge murale de
4" (10,2 cm) normalement utilisée pour un équipement de
buanderie.
Utiliser un conduit métallique uniquement. Un conduit en
métal rigide est recommandé.
La longueur du système d’évacuation et le nombre de coudes
doivent être réduits au minimum pour des performances
optimales.
Pour un fonctionnement efficace et silencieux :
Ne pas utiliser plus de trois coudes à 90°.
Veiller à ce qu’il y ait une section droite de conduit d'un
minimum de 24" (61,0 cm) entre les raccords coudés, si on
doit en utiliser plus d'un.
Ne pas installer 2 coudes successifs.
Au niveau de chaque jointure du circuit d'évacuation, assurer
l'étanchéité avec les brides de serrage.
Le circuit d’évacuation doit comporter un clapet anti-reflux. Si
la bouche de décharge murale ou par le toit comporte un
clapet, ne pas utiliser le clapet fourni avec la hotte de
cuisinière.
12"
(30,5 cm)
3¹⁄₈"
(7,9 cm)
30" (76,2 cm)
36" (91,4 cm)
23" (58,4 cm)
10"
(25,4 cm)
³⁄₈"
(1,0 cm)
2⁹⁄₁₆"
(6,5 cm)
7½"
(19,0 cm)
29¹⁄₈" (74,0 cm): modèles 30" (76,2 cm)
35¹⁄₈" (89,2 cm): modèles 36" (91,4 cm)
1¹⁄₈"
(2,9 cm)
7" (17,8 cm): modèles 30" (76,2 cm)
9⁷⁄₈" (25,0 cm): modèles 36" (91,4 cm)
Opercules arrachables du
conduit d'évacuation
7⁷⁄₈"
(20,0 cm)
12³⁄₁₆" (31,0 cm)
⁵⁄₈"
(1,6 cm)
Modèles 30" (76,2 cm) : 12¼" (31,1 cm)
Modèles 36" (91,4 cm) : 15" (38,1 cm)
A. Pour les installations avec hotte
uniquement. 70" (177,8 cm)
minimum au-dessus de la
surface de cuisson
électrique.76" (193,0 cm)
minimum au-dessus de la
surface de cuisson à gaz.
B. Pour les installations avec
cache-conduit facultatif.
82" (208.3 cm) minimum au-
dessus d'une surface de
cuisson électrique. 88"
(223,5 cm) minimum au-
dessus d'une surface de
cuisson à gaz.
13" (33,0 cm)
18" (45,7 cm)
de dégagement minimum
entre le placard supérieur
et le plan de travail
36" (91,4 cm)
de hauteur jusqu'au
plan de travail
30" (76,2 cm), 36" (91,4 cm),
cavité d'encastrement
(en cas d'installation entre des placards)
A B
Du bas de la hotte
à la surface de cuisson
Cavité d'encastrement
minimum
Couvercle de l'évent
(le cas échéant)
Hotte
X
19
À l’aide d’un produit de calfeutrage, assurer l’étanchéi
autour de la bouche de décharge à l’extérieur (à travers le
mur ou le toit).
La taille du conduit doit être uniforme.
Installations dans les régions au climat froid
On doit installer un clapet anti-retour supplémentaire à l’arrière
pour minimiser le reflux d’air froid et incorporer un élément
d’isolation thermique pour minimiser la conduction de chaleur
par l’intermédiaire du conduit d’évacuation, de l’intérieur de la
maison à l’extérieur. Le clapet anti-retour être placé du côté air
froid de la barrière thermique.
L’élément d’isolation thermique doit être aussi proche que
possible de l’endroit où le circuit d’évacuation s’introduit dans la
partie chauffée de la maison.
Air d’appoint
Les codes locaux en bâtiment peuvent imposer l’emploi d’un
circuit de renouvellement de l’air/introduction d’air d’appoint, lors
de l’utilisation d’un circuit d’aspiration de débit supérieur à une
valeur spécifiée en pieds cubes par minute. Le débit spécifié en
pieds cubes par minute varie d’une juridiction à l’autre. Consulter
un professionnel des installations de chauffage ventilation/
climatisation au sujet des exigences spécifiques applicables
dans la juridiction locale.
Méthodes d’évacuation
Cette hotte est configurée à l’usine pour la décharge de l’air
aspiré à travers le toit ou à travers un mur.
Pour l'installation on a besoin d'un circuit d'évacuation de
conduit rectangulaire 3¹⁄₄" x 10" (8,3 x 25,4 cm). L'ouverture de
décharge de la hotte est 3¹⁄₄" x 10" (8,3 x 25,4 cm). La sortie à
l’extérieur du circuit d’évacuation peut se faire à travers le toit ou
à travers un mur. Un coude à 90° est nécessaire pour aspirer l'air
du dessus de la hotte et à travers un mur. Voir la section
“Installation de la hotte” pour les détails pour l'installation d'un
clapet anti-reflux.
REMARQUE : On déconseille l’emploi d’un conduit flexible. Un
conduit flexible peut susciter une rétro-pression et des
turbulences de l’air, ce qui réduit considérablement la
performance.
Décharge à l’arrière
L'air aspiré par la hotte peut être déchargé directement à l'arrière
à l'aide du clapet anti-reflux rectangulaire 3¼" x 10"
(8,3 cm x 25,4 cm) (fourni) en même temps qu'un circuit
d'évacuation de conduit rectangulaire 3¼" x 10"
(8,3 cm x 25,4 cm) (non fourni). Voir la section "Installation de la
hotte" pour les détails pour l'installation d'un clapet anti-reflux.
Calcul de la longueur effective du circuit d’évacuation
Pour calculer la longueur effective du circuit d’évacuation
nécessaire, additionner les longueurs équivalentes (en pieds ou
mètres) de tous les composants utilisés dans le système.
Système de décharge de ⁄₄" x 10" (8,3 cm x 25,4 cm)
Exemple de circuit d’évacuation
Décharge à travers le toit Décharge à travers le mur
(décharge par le dessus ou
par l'arrière)
A. Bouche de décharge sur toit
B. Conduit rectangulaire
métallique 3
¹⁄₄
" x 10"
(8,3 x 25,4 cm)
A. Bouche de décharge murale
B. Conduit rectangulaire
métallique 3
¹⁄₄
" x 10"
(8,3 x 25,4 cm)
A
B
A
B
Composant
Coude à 90° de
3¹⁄₄" x 10" (8,3 cm x 25,4 cm) 5,0 pi
(1,5 m)
Coude plat de
3¹⁄₄" x 10" (8,3 cm x 25,4 cm) 12,0 pi
(3,7 m)
Bouche de décharge murale
de 3¹⁄₄" x 10" (8,3 cm x
25,4 cm)
0,0 pi
(0,0 m)
Longueur maximale recommandée = 35 pi (10,7 m)
1 coude à 90° = 5,0 pi (1,5 m)
Section droite de 8 pi (2,4 m) = 8 pi (2,4 m)
1 bouche de décharge murale = 0 pi (0 m)
Longueur du système de 3¹⁄₄" x 10"
(8,3 cm x 25,4 cm)
= 13 pi (3,9 m)
Bouche de
décharge murale
Coude de 3 ¹⁄₄" x 10"
(8,3 x 25,4 cm)
2 pi (0,6 m)
6 pi (1,8 m)
20
Spécifications électriques
Observer les dispositions de tous les codes et règlements en
vigueur.
Vérifier que l'installation électrique a été correctement effectuée
et qu'elle est conforme aux spécifications de la plus récente
édition des normes National Electrical Code, ANSI/NFPA 70, ou
de la norme CSA C22.1-94, Code canadien de l'électricité, partie
1 et C22.2 N° 0-M91 (dernière édition) et de tous les codes et
règlements en vigueur locaux.
Si les codes le permettent et si on utilise un conducteur distinct
de liaison à la terre, il est recommandé qu'un électricien qualif
vérifie la qualité de la liaison à la terre.
Pour obtenir un exemplaire de la norme des codes ci-dessus,
contacter :
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
L'appareil doit être alimenté par un circuit de 120 V, CA
seulement, 60 Hz, 15 A, protégé par fusible.
Si le domicile est équipé d'un câblage en aluminium, suivre
les instructions suivantes :
1. Connecter une section de câble en cuivre massif aux
conducteurs en queue de cochon.
2. Connecter le câblage en aluminium à la section ajoutée
de câblage en cuivre en utilisant des connecteurs et/ou
des outils spécialement conçus et homologués UL pour
fixer le cuivre à l'aluminium.
Appliquer la procédure recommandée par le fabricant des
connecteurs. La connexion aluminium/cuivre doit être
conforme aux codes locaux et aux pratiques de câblage
acceptées par l'industrie.
Le calibre des conducteurs et les connexions doivent être
compatibles avec la demande de courant de l'appareil
spécifiée sur la plaque signalétique. La plaque signalétique
de l'appareil est située derrière le filtre, sur la paroi arrière de
la hotte.
Le calibre des conducteurs doit satisfaire aux exigences de la
plus récente édition de la norme National Electrical Code,
ANSI/NFPA 70, ou de la norme CSA C22.1-94, Code
canadien de l'électricité, partie 1 et C22.2 n° 0-M91 (dernière
édition) et de tous les codes et règlements en vigueur.
INSTRUCTIONS D'INSTALLATION
Préparation de l'emplacement
Il est recommandé d'installer le conduit de décharge avant de
procéder à l'installation de la hotte.
Si l'on installe un cache-conduit pleine largeur (facultatifs),
suivre les instructions fournies avec ce produit.
Avant d’exécuter les découpages, vérifier la disponibilité d’un
dégagement suffisant dans le plafond ou le mur pour le
conduit d’évacuation.
Avant de sélectionner la hotte à installer, mesurer la hauteur
libre sous plafond et la hauteur maximum disponible sous la
hotte.
1. connecter la source de courant électrique.
2. terminer la méthode d’évacuation à utiliser : décharge à
travers le mur ou le toit, ou recyclage.
3. lectionner une surface plane pour l’assemblage de la
hotte. Placer le matériau de protection sur cette surface.
4. À l’aide de deux personnes ou plus, soulever la hotte et la
poser sur la surface couverte.
REMARQUE : Cette hotte de cuisine peut être montée sur des
placards ou sur le mur.
Pour les installations sur des placards
1. Si le fond du placard forme une cavité, ajouter des tringles
d’appui en bois de chaque côté. Installer les vis pour fixer les
tringles d’appui aux emplacements indiqués.
Déterminer l’emplacement du trou de passage du câble
Percer seulement un trou de passage de 1¹⁄₄" (3,2 cm) de
diamètre pour le câblage. Voir l’étape 2 pour des instructions sur
l’emplacement du trou de passage du câblage.
AVERTISSEMENT
Risque du poids excessif
Utiliser deux ou plus de personnes pour déplacer et
installer la hotte de la cuisinière.
Le non-respect de cette instruction peut causer
une blessure au dos ou d'autre blessure.
3"
(7,6 cm)
3"
(7,6 cm)
Tringles d'appui en bois
(seulement pour fond de
placard avec cavité)
Bord inf. du placard
Mur
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

KitchenAid KVUC600JSS Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues