DRYER SAFETY ..........................................................................2
INSTALLATION REQUIREMENTS ..............................................4
Tools and Parts .................................................................... 4
Location Requirements ......................................................5
ELECTRICAL REQUIREMENTS – U.S.A. ONLY
(SPÉCIFICATIONS ÉLECTRIQUES – ÉTATS-UNIS
SEULEMENT) ..............................................................................7
Electrical Requirements .....................................................7
ELECTRIC DRYER POWER HOOKUP – CANADA ONLY ......... 8
Electrical Requirements .....................................................8
GAS DRYER POWER HOOKUP – U.S.A. AND CANADA ..........8
Electrical Requirements .....................................................8
Gas Supply Requirements ..................................................9
Install Leveling Legs .........................................................10
MAKE ELECTRICAL CONNECTION – U.S.A. ONLY
(EFFECTUER LE RACCORDEMENT ÉLECTRIQUE –
ÉTATS-UNIS SEULEMENT) ......................................................11
Electrical Connection Options .........................................11
Power Supply Cord Connection.......................................12
Direct Wire Connection.....................................................13
MAKE GAS CONNECTION ....................................................... 16
VENTING ....................................................................................17
Venting Requirements .......................................................17
Plan Vent System ...............................................................18
Venting Kits ........................................................................ 18
INSTALL VENT SYSTEM ..........................................................19
CONNECT INLET HOSES .........................................................20
CONNECT VENT .......................................................................21
LEVEL DRYER ........................................................................... 21
COMPLETE INSTALLATION CHECKLIST ...............................22
REVERSE DOOR SWING (OPTIONAL) ....................................22
TROUBLESHOOTING ...............................................................24
INSTALLATION NOTES
Date of purchase: _________________________________
Date of installation: _______________________________
Installer: ________________________________________
Model number: ___________________________________
Serial number: ___________________________________
Date d’achat : _____________________________________
Date d’installation : ________________________________
Installateur : ______________________________________
Numéro de modèle : ________________________________
Numéro de série : __________________________________
NOTES CONCERNANT L’INSTALLATION
Table des matières
SÉCURITÉ DE LA SÉCHEUSE ................................................. 25
EXIGENCES D’INSTALLATION ................................................ 27
Outillage et pièces ............................................................ 27
Exigences d’emplacement ............................................... 28
RACCORDEMENT DE LA SÉCHEUSE ÉLECTRIQUE –
CANADA SEULEMENT ............................................................. 30
Spécications électriques ................................................ 30
RACCORDEMENT D’UNE SÉCHEUSE À GAZ ....................... 31
Spécications électriques ................................................ 31
Spécications de l’alimentation en gaz .......................... 31
Installation des pieds de nivellement .............................. 33
Raccordement au gaz ....................................................... 33
ÉVACUATION ............................................................................ 34
Exigences concernant l’évacuation ................................ 34
Planication du système d’évacuation ........................... 35
Trousses d’évacuation ...................................................... 36
INSTALLATION DU CIRCUIT D’ÉVACUATION ........................ 37
RACCORDEMENT DES TUYAUX D’ALIMENTATION ............. 37
RACCORDEMENT DU CONDUIT D’ÉVACUATION ................ 39
RÉGLAGE DE L’APLOMB DE LA SÉCHEUSE......................... 39
ACHEVER L’INSTALLATION – LISTE DE VÉRIFICATION ....... 39
INVERSION DU SENS DE L’OUVERTURE DE LA PORTE
(FACULTATIF)
............................................................................. 40
DÉPANNAGE ............................................................................. 42
Gas and Electric Dryer Installation Instructions
29" Wide Models
Instructions d’installation de la sécheuse à gaz et électrique
Modèles de largeur 29"
Para obtener acceso al manual de uso y cuidado en español, o para obtener información adicional acerca de su producto, visite:
www.whirlpool.com o www.maytag.com
Tenga listo su número de modelo completo. Puede encontrar el número de modelo y de serie dentro de la cavidad superior de la puerta.
2
DRYER SAFETY
3
4
Tools and Parts
Gather the required tools and parts before starting installation.
Tools needed for all installations:
Level
Tape measure
Pliers
Flat-blade screwdriver #2 Phillips screwdriver
Adjustable wrench that
opens to 1" (25 mm) or
hex-head socket wrench
Tin snips (new vent
installations)
Caulking gun and
compound (for installing
new exhaust vent)
Vent clamps
1/4" nut driver or socket
wrench (recommended)
Utility knife
INSTALLATION REQUIREMENTS
Putty knife
Parts supplied (steam models):
“Y” connector
Short inlet hose
5' (1.52 m) inlet hose
Rubber washer
Parts needed (steam models):
Parts package is located in dryer drum. Check that all parts
are included.
Parts supplied (all models):
Tools needed for gas installations:
8" (203 mm) or 10"
(254 mm) pipe wrench
8" (203 mm) or 10"
(254 mm) adjustable wrench
(for gas connections)
Pipe-joint compound
resistant to LP gas
Leveling legs (4)
(Length and appearance of legs may vary according to model)
Wire Stripper (direct wire
installations)
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be
at least 4 ft. (1.22 m) long. The wires that connect to
the dryer must end in ring terminals or spade terminals
with upturned ends.
A UL listed strain relief.
or
5
Parts needed: (Not supplied with dryer)
Check local codes. Check existing electrical supply and venting.
See “Electrical Requirements” and “Venting Requirements”
before purchasing parts.
Mobile home installations require metal exhaust system hardware
available for purchase from the dealer from whom you purchased
your dryer. For further information, please refer to the “Assistance
or Service” section in your “Use and Care Guide.”
Optional Equipment: (Not supplied with dryer)
Refer to your “Use and Care Guide” for information about
accessories available for your dryer.
Location Requirements
You will need:
A location allowing for proper exhaust installation. See
“Venting Requirements.”
A separate 15 or 20-amp circuit needed for gas dryers and
30-amp circuit needed for electric dryers.
If you are using power supply cord, a grounded electrical
outlet located within 2 ft. (610 mm) of either side of dryer.
See “Electrical Requirements.”
A sturdy oor to support dryer and a total weight (dryer
and load) of 200 lbs. (90.7 kg). The combined weight of a
companion appliance should also be considered.
Level oor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended
Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
For garage installation, place dryer at least 18" (460 mm)
above oor.
Steam models only: Cold water faucet located within 4 ft.
(1.2 m) of the water ll valves, and water pressure of 20-100
psi (137.9-689.6 kPa). You may use the water supply for your
washer using the “Y” connector and short hose which are
provided.
IMPORTANT: Do not operate, install, or store dryer where it
will be exposed to water, weather, or at temperatures below
45°F (7°C). Lower temperatures may cause dryer not to shut
off at end of automatic sensor cycles, resulting in longer drying
times.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
Installation clearances:
For each arrangement, consider allowing more space for ease of
installation and servicing, spacing for companion appliances, and
clearances for walls, doors, and oor moldings. Space must be
large enough to allow door to fully open. Add spacing on all sides
of dryer to reduce noise transfer. If a closet door or louvered door
is installed, top and bottom air openings in door are required.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Dryer Dimensions
Front View
50
3
/4"
(1289 mm)
42"
(1067 mm)
28
1
/4"
(717 mm)
28
1
/4"
(717 mm)
NOTE: Minimum height of leveling legs should be 1/2" (13 mm),
or to match the height of the accompanying washer.
Side View
29"
(737 mm)
40
7
/8"
(1038 mm)
1
/2"
(13 mm)
A B
A. Wide opening side-swing door
B. Wide opening hamper door
6
Installation Spacing
6"/0"
(152 mm/
0 mm)
14" max
(356 mm)
1"/0"
(25 mm/0 mm)
1"/1"
(25 mm/25 mm)
18"/18"
(457 mm/
457 mm)
3"/3"
(76 mm/
76mm)
3"/3"
(76 mm/
76mm)
48"
2
/48"
2
(310 cm
2/
310 cm
2
)
24"
2/
24"
2
(155 cm
2/
155 cm
2
)
Recommended/Minimum spacing
Back View
14
1
/
2
"
(368 mm)
4
3
/4"
(121 mm)
9
1
/4"
(235 mm)
1
1
/4"
(32 mm)
14
1
/
2
"
(368 mm)
4
3
/4"
(121 mm)
9
1
/4"
(235 mm)
1
1
/4"
(32 mm)
30
1
/4"
(768 mm)
4"
(101 mm)
Steam Non-Steam
Mobile home – Additional installation
requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280) or the Canadian
Manufactured Home Standard CAN/CSA-Z240 MH.
Metal exhaust system hardware, available for purchase.
For further information, please reference the “Assistance
or Service” section of the “Use and Care Guide.”
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such
as a nearby window) should be at least twice as large
as the dryer exhaust opening.
For gas dryers mobile home installations:
Mobile Home Installation Hold-down Kit Part Number
W10432680 is available to order. For further information,
see “Assistance or Service” section in your “Use and
Care Guide.”
Installation spacing for recessed area
or closet
The dimensions shown are for the minimum spacing allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door,
and oor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer
is recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
7
ELECTRICAL REQUIREMENTS –
U.S.A. ONLY (SPÉCIFICATIONS
ÉLECTRIQUES – ÉTATS-UNIS
SEULEMENT)
Electrical Requirements
It is your responsibility:
To contact a qualied electrical installer.
To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA
70 - latest edition and all local codes and ordinances.
The National Electrical Code requires a 4-wire power
supply connection for homes built after 1996, dryer circuits
involved in remodeling after 1996, and all mobile home
installations.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch
Park, Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240
volt, 60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208
volt electrical supply, if specied on the serial/rating plate)
on a separate 30-amp circuit, fused on both sides of the
line. Connect to an individual branch circuit. Do not have
a fuse in the neutral or grounding circuit.
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is
recommended that a qualied electrician determine that
the ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
This dryer is manufactured ready to install with a 3-wire
electrical supply connection. The neutral ground conductor
is permanently connected to the neutral conductor (white
wire) within the dryer. If the dryer is installed with a 4-wire
electrical supply connection, the neutral ground conductor
must be removed from the external ground connector (green
screw), and secured under the neutral terminal (center or
white wire) of the terminal block. When the neutral ground
conductor is secured under the neutral terminal (center
or white wire) of the terminal block, the dryer cabinet is
isolated from the neutral conductor.
If local codes do not permit the connection of a neutral
ground wire to the neutral wire, see “Optional 3-wire
connection” section.
A 4-wire power supply connection must be used when the
appliance is installed in a location where grounding through
the neutral conductor is prohibited. Grounding through the
neutral is prohibited for (1) new branch-circuit installations,
(2) mobile homes, (3) recreational vehicles, and (4) areas
where local codes prohibit grounding through the neutral
conductors.
4-wire
receptacle
(14-30R)
If your outlet looks like this:
Then choose a 4-wire power supply cord with
ring or spade terminals and UL listed strain
relief. The 4-wire power supply cord, at least
4 ft. (1.22 m) long, must have 4 10-gauge solid
copper wires and match a 4-wire receptacle of
NEMA Type 14-30 R. The ground wire (ground
conductor) may be either green or bare. The
neutral conductor must be identied by a
white cover.
3-wire
receptacle
(10-30R)
If your outlet looks like this:
Then choose a 3-wire power supply cord with
ring or spade terminals and UL listed strain
relief. The 3-wire power supply cord, at least
4 ft. (1.22 m) long, must have 3 10-gauge solid
copper wires and match a 3-wire receptacle
of NEMA Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
Flexible armored cable or nonmetallic sheathed copper
cable (with ground wire), covered with exible metallic
conduit. All current-carrying wires must be insulated.
10-gauge solid copper wire (do not use aluminum) at least
5 ft. (1.52 m) long.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be
at least 4 ft. (1.22 m) long. The wires that connect to
the dryer must end in ring terminals or spade terminals
with upturned ends.
A UL listed strain relief.
8
4-wire receptacle
(14-30R)
ELECTRIC DRYER POWER HOOKUP –
CANADA ONLY
ELECTRICAL REQUIREMENTS
It is your responsibility:
To contact a qualied electrical installer.
To be sure that the electrical connection is adequate and in
conformance with Canadian Electrical Code, C22.1-latest
edition and all local codes. A copy of above codes standard
may be obtained from: Canadian Standards Association,
178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4 wire, single phase, 120/240 volt,
60 Hz, AC only electrical supply on a separate 30-amp
circuit, fused on both sides of the line. A time-delay fuse
or circuit breaker is recommended. Connect to an individual
branch circuit.
This dryer is equipped with a CSA
International Certied Power Cord
intended to be plugged into a standard
14-30R wall receptacle. The cord is
5 ft. (1.52 m) long. Be sure wall receptacle
is within reach of dryer’s nal location.
If using a replacement power supply cord, it is recommended
that you use Power Supply Cord Replacement Part Number
9831317.
For further information, please reference service numbers located
in “Assistance or Service” section of your Use and Care Guide.
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualied electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not t the outlet, have a proper outlet
installed by a qualied electrician.
GAS DRYER POWER HOOKUP –
U.S.A. AND CANADA
ELECTRICAL REQUIREMENTS
120 Volt, 60 Hz, AC only, 15- or 20-amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate
circuit serving only this dryer be provided.
9
Gas Supply Requirements
Gas type
Natural gas:
This dryer is equipped for use with Natural Gas. It is design-
certied by CSA International for LP (propane or butane) gases
with appropriate conversion.
Your dryer must have the correct burner for the type of gas
in your home. Burner information is located on the rating
plate in the door well of your dryer. If this information does
not agree with the type of gas available, please reference the
“Assistance or Service” section of the Use and Care Guide.
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualied electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not t the outlet, have a proper outlet
installed by a qualied electrician.
LP Gas Conversion:
IMPORTANT: Conversion must be made by a qualied
technician.
No attempt shall be made to convert the dryer from the gas
specied on the model/serial rating plate for use with a different
gas without consulting your gas company.
GAS SUPPLY LINE
Option 1 (Recommended Method)
Flexible stainless steel gas connector:
If local codes permit, use a new exible stainless steel gas
connector (Design Certied by the American Gas Association
or CSA International) to connect your dryer to the rigid
gas supply line. Use an elbow and a 3/8" are x 3/8" NPT
adapter tting between the stainless steel gas connector and
the dryer gas pipe, as needed, to prevent kinking.
Option 2 (Alternate Method)
Approved aluminum or copper tubing
Must include 1/8" NPT minimum plugged tapping accessible
for test gauge connection, immediately upstream of the gas
connection to the dryer.
1/2" IPS pipe is recommended.
3/8" approved aluminum or copper tubing is acceptable
for lengths under 20 ft. (6.1 m) if local codes and gas
supplier permit.
If you are using Natural gas, do not use copper tubing.
Lengths over 20 ft. (6.1 m) should use larger tubing and
a different size adapter tting.
If your dryer has been converted to use LP gas, 3/8" LP
compatible copper tubing can be used. If the total length
of the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of LP
gas must be used. Do not use TEFLON
®†
tape.
Must include shut-off valve
In the U.S.A.:
An individual manual shut-off valve must be installed within
six (6) ft. (1.8 m) of the dryer in accordance with the National
Fuel Gas Code, ANSI Z223.1. The location should be easy
to reach for opening and closing.
In Canada:
An individual manual shut-off valve must be installed in
accordance with the B149.1, Natural Gas and Propane
Installation Code. It is recommended that an individual
manual shutoff valve be installed within six (6) ft. (1.8 m)
of the dryer. The location should be easy to reach for
opening and closing.
†®TEFLON is a registered trademark of Chemours.
10
Dryer gas pipe
The gas pipe that comes out through the rear of your dryer
has a 3/8" male pipe thread.
9
1
/4"
(235 mm)
1
1
/4"
(32 mm)
3/8" NPT dryer gas pipe
GAS SUPPLY CONNECTION REQUIREMENTS
Use an elbow and a 3/8"  are x 3/8" NPT adapter  tting
between the  exible gas connector and the dryer gas pipe,
as needed, to avoid kinking.
Use only pipe-joint compound. Do not use TEFLON
®
tape.
This dryer must be connected to the gas supply line with a
listed  exible gas connector that complies with the standard
for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
BURNER INPUT REQUIREMENTS
Elevations above 2,000 ft. (610 m):
When installed above 2,000 ft. (610 m), a 4% reduction of the
burner Btu rating shown on the model/serial number plate is
required for each 1,000 ft. (305 m) increase in elevation.
Gas supply pressure testing
The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than
1/2 psi.
A. 3/8"  exible gas connector
B. 3/8" pipe to  are adapter  tting
C. 1/8" NPT minimum plugged tapping
D. 1/2" NPT gas supply line
E. Gas shutoff valve
E
BA
D
C
INSTALL LEVELING LEGS
Screw in leveling legs
2.
Using a wrench and tape measure, screw leveling legs into
leg holes until bottom of foot is approximately 1/2" (13 mm)
from bottom of dryer (so that the dryer height matches that
of the accompanying washer).
Now stand the dryer on its feet. Slide the dryer until it is
close to its  nal location. Leave enough room to connect
the exhaust vent.
For mobile home use
Gas dryers must be securely fastened to the  oor.
Mobile home installations require a Mobile
Home Installation Hold-down Kit. For
ordering information, please reference
the “Use and Care Guide.”
Prepare dryer for leveling legs
1.
To avoid damaging  oor, use a large,  at piece of cardboard
from dryer carton; place under entire back edge of dryer.
Firmly grasp dryer body (not console panel) and gently lay
dryer down on cardboard.
or
11
MAKE ELECTRICAL CONNECTION – U.S.A. ONLY (EFFECTUER LE
RACCORDEMENT ÉLECTRIQUE – ÉTATS-UNIS SEULEMENT)
Power Supply Cord
ELECTRICAL CONNECTION OPTIONS
1. Choose electrical connection type
Power supply cord 4-wire receptacle
(NEMA Type 14-30R): Go to steps 1-2
on page 12 for power supply cord strain
relief; then steps 3-6 for 4-wire Power
Supply Cord Connection section. Then,
go to Venting Requirements.
3-wire direct connection: Go to steps
1-2 on page 13 for direct wire strain relief;
then steps 3-7 for 3-wire Direct Wire
Connection section. Then go to Venting
Requirements.
4-wire direct connection: Go to steps
1-2 on page 13 for direct wire strain relief;
then steps 3-8 for 4-wire Direct Wire
Connection section. Then go to Venting
Requirements.
Power supply cord 3-wire receptacle
(NEMA Type 10-30R): Go to steps 1-2
on page 12 for power supply cord strain
relief; then steps 3-5 for 3-wire Power
Supply Cord Connection section. Then
go to Venting Requirements.
NOTE: If local codes do not permit connection of a
cabinet-ground conductor to neutral wire, go to “Optional
3-wire Connection” section. This connection may be
used with either a power supply cord or a direct wire
connection.
Direct Wire
A
B
CCE F
D
2. Remove terminal block cover
Before you start, disconnect power. Remove hold-down
screw (D) and terminal block cover (A).
A. Terminal block cover
B. External ground conductor screw
C. Center terminal block screw
D. Hold-down screw
E. Neutral ground wire
F. Hole below terminal block cover
12
Put power supply cord through the strain relief. Be sure that
the wire insulation on the power supply cord is inside the
strain relief. The strain relief should have a tight  t with the
dryer cabinet and be in a horizontal position. Do not further
tighten strain relief screws at this point.
For 3-wire Power Supply Cord Connection,
continue to step 3 on page 13.
For 4-wire Power Supply Cord Connection,
continue to step 3 on this page.
Attach power supply cord
to strain relief
2.
D
C
B
A
Attach power supply cord
strain relief
Remove the screws from a 3/4" (19 mm) UL listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp
sections (C) into the hole (B) below the terminal block opening
so that one tab is pointing up (A) and the other is pointing
down (D), and hold in place. Tighten strain relief screws just
enough to hold the two clamp sections (C) together.
1.
Power supply cord strain relief
POWER SUPPLY CORD CONNECTION
4-wire Power Supply Cord Connection
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).
B
A
E
Prepare to connect neutral
ground wire and neutral wire
3.
IMPORTANT: A 4-wire connection is required for mobile
homes and where local codes do not permit the use of 3-wire
connections.
A. 4-wire receptacle (NEMA type 14-30R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
E. Spade terminals with upturned ends
F. 3/4" (19 mm) UL listed strain relief
G. Ring terminals
B
CE
Connect neutral ground wire
and neutral wire
4.
Connect neutral ground wire (E) and neutral wire (white or
center) (C) of power supply cord under center terminal block
screw (B). Tighten screw.
A
F
Connect ground wire (F) (green or bare) of power supply cord
to external ground conductor screw (A). Tighten screw.
5. Connect ground wire
A.
B.
D.
C.
E. F.
G.
13
3-wire Power Supply Cord Connection
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
A. 3-wire receptacle (NEMA type 10-30R)
B. 3-wire plug
C. Neutral prong
D. Spade terminals with upturned ends
E. 3/4" (19 mm) UL listed strain relief
F. Ring terminals
G. Neutral (white or center wire)
Connect remaining wires
6.
Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinstall terminal block cover.
Secure cover with hold-down screw. Now, go to Venting
Requirements.
Remove center terminal block screw (B).
B
3. Remove center screw
Unscrew the removable conduit connector (A) and any
screws from a 3/4" (19 mm) UL listed strain relief (UL marking
on strain relief). Put the threaded section of the strain relief
through the hole (B) below the terminal block opening.
Reaching inside the terminal block opening, screw the
removable conduit connector onto the strain relief threads (C).
C
B
A
1. Attach direct wire strain relief
Put direct wire cable through the strain relief. The strain relief
should have a tight  t with the dryer cabinet and be in a
horizontal position. Tighten strain relief screws.
For 3-wire Direct Wire Connection, continue to step 3
on page 15.
For 4-wire Direct Wire Connection, continue to step 3
on the next page.
2. Attach direct wire cable
to strain relief
Direct wire strain relief
4. Connect neutral wire
Connect neutral wire (white or center) (C) of power supply cord
to center terminal block screw (B). Tighten screw.
B
C
B
5. Connect remaining wires
Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinstall terminal block cover.
Secure cover with hold-down screw. Now, go to Venting
Requirements.
DIRECT WIRE CONNECTION
A.
B.
E.
C.
D.
F.
G.
14
4-wire Direct Wire Connection
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit 3-wire connections.
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving
bare ground wire at 5" (127 mm). Cut 1
1
/
2
" (38 mm) from
remaining 3 wires. Strip insulation back 1" (25 mm). Shape
ends of wires into hooks.
1"
(25 mm)
3
1
2
"
(89 mm)
5"
(127 mm)
3. Prepare your 4-wire cable
for direct connection
To connect wires to terminal block, place hooked end of
wire under terminal block screw, facing to the right, squeeze
hooked end together, and tighten screw.
4. Connect wires to terminal block
5. Prepare to connect neutral
ground wire and neutral wire
B
A
E
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).
7. Connect ground wire
FE
A
Connect ground wire (green or bare) (F) of direct wire cable
to external ground conductor screw (A). Tighten screw.
B
E C
6. Connect neutral ground wire
and neutral wire
Connect neutral ground wire (E) and place hooked end (hook
facing right) of neutral wire (white/center wire) (C) of direct
wire cable under center screw of terminal block (B). Squeeze
hooked ends together and tighten screw.
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze
hooked ends together and tighten screws. Finally, reinstall
terminal block cover. Now, go to Venting Requirements.
8. Connect remaining wires
15
3-wire Direct Wire Connection
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
B
5. Remove center screw
Remove center terminal block screw (B).
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 3
1
/
2
" (89 mm) of outer covering from end of cable. Strip
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape wire ends
into hooks.
1"
(25 mm)
3½"
(89 mm)
3. Prepare your 3-wire cable
for direct connection
To connect wires to terminal block, place hooked end of wire
under terminal block screw, facing to the right, squeeze
hooked end together, and tighten screw.
4. Connect wires to terminal block
1. Prepare to connect neutral
ground wire and neutral wire
B
A
E
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).
Optional 3-wire Connection
You must verify with a quali ed electrician that this grounding
method is acceptable before connecting.
Connect remaining wires
7.
Place hooked ends of remaining direct wire cable wires
under outer terminal block screws (hooks facing right).
Squeeze hooked ends together and tighten screws. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to
Venting Requirements.
B
C
Place hooked end of neutral wire (white or center) (C) of direct
wire cable under center terminal block screw (B). Squeeze
hooked end together. Tighten screw.
6. Connect neutral wire
16
B
CE
Connect neutral ground wire
and neutral wire
2.
Connect neutral ground wire (E) and neutral wire (white or
center wire) (C) of power supply cord or cable under center
terminal block screw (B). Tighten screw.
Connect remaining wires
3.
Place hooked ends of remaining wires under outer terminal
block screws (hooks facing right). Tighten screws.
A
E
Connect external ground wire
4.
Connect a separate copper ground wire (G) from the external
ground conductor screw (A) to an adequate ground. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to
Venting Requirements.
A
B
D
C
2. Plan pipe  tting connection
A combination of pipe  ttings must be used to connect dryer
to existing gas line. A recommended connection is shown.
Your connection may be different, according to supply line
type, size, and location.
A. 3/8"  exible gas connector
B. 3/8" dryer pipe
C. 3/8" to 3/8" pipe elbow
D. 3/8" pipe-to- are adapter  tting
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing
on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leaks found.
A
B
1. Connect gas supply to dryer
Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound
on threads of all non- ared male  ttings. If  exible metal
tubing is used, be sure there are no kinks.
NOTE: For LP gas connections, you must use pipe-joint
compound resistant to action of LP gas. Do not use
TEFLON
®
tape.
MAKE GAS CONNECTION
Closed valve
Open valve
3. Open shut-off valve
Non- ared
male  tting
Flared
male  tting
G
17
VENTING
Venting Requirements
4"
(102 mm)
4" (102 mm) heavy metal exhaust vent
WARNING: To reduce the risk of re, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or exible metal vent shall be used for
exhausting.
Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
Do not use plastic or metal foil vent.
Rigid metal vent:
Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
Must be fully extended and supported in nal dryer location.
Remove excess to avoid sagging and kinking that may result
in reduced airow and poor performance.
Do not install in enclosed walls, ceilings, or oors.
The total length should not exceed 7
3
/
4
ft. (2.4 m).
NOTE: If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not plugged
with lint. Replace plastic or metal foil vents with rigid metal
or exible metal vents. Review “Vent System Chart” and, if
necessary, modify existing vent system to achieve best drying
performance.
Exhaust hoods:
Must be at least 12" (305 mm) from ground or any object
that may obstruct exhaust (such as owers, rocks, bushes,
or snow).
Elbows:
45° elbows provide better airow than 90° elbows.
Clamps:
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct tape.
See “Venting Kits” for more information.
Recommended Styles:
Acceptable Style:
Louvered hood Box hood
Angled hood
Good
Better
18
Plan Vent System
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
B
B
C
D
E
E
F
G
H
A
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
F. Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
Standard rear offset exhaust installation
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance installations are shown.
Refer to the manufacturer’s instructions.
Over-The-Top installation
(also available with one offset elbow)
Periscope installation
NOTE: The following kits for close clearance alternate
installations are available for purchase.
Venting Kits
For more information, call 1-866-698-2538 (Whirlpool)
or 1-800-344-1274 (Maytag), or visit us at
www.applianceaccessories.com (Whirlpool)
or www.maytag.com (Maytag).
In Canada, call 1-800-688-2002 (Whirlpool and Maytag) or visit
us at www.whirlpoolparts.ca (Whirlpool) or www.maytag.ca
(Maytag).
Part Number Descriptions
8171587RP 0"-5" Metal vent periscope
4396037RP 0"-18" Metal vent periscope
4396011RP 18"-29" Metal vent periscope
4396014 29"-50" Metal vent periscope
4392892 In-Wall metal DuraVent™ Periscope
4396028 Sure Connect™ venting kit
(over-the-top installation)
4396009RP 5' Universal connect vent, exible dryer venting
4396010RP 6' SecureConnect™ vent, exible dryer venting
4396013RB Dryer vent installer’s kit
4396033RP 5' exible dryer venting with clamps
4396727RP 8' exible dryer venting with clamps
4396004 Dryer offset elbow
4396005 Wall offset elbow
4396006RW DuraSafe™ close elbow
4396007RW Through-the-wall vent cap
4396008RP 4" steel dryer venting clamps - 2 pack
8212662 Flush mounting louvered vent hood 4"
19
Special provisions for mobile home
installations:
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path:
Select route that will provide straightest and most direct path
outdoors.
Plan installation to use fewest number of elbows and turns.
When using elbows or making turns, allow as much room
as possible.
Bend vent gradually to avoid kinking.
Use as few 90° turns as possible.
Determine vent length and elbows needed
for best drying performance:
Use following “Vent System Chart” to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those speci ed
in “Vent System Chart.” Exhaust systems longer than those
speci ed will:
Shorten life of dryer.
Reduce performance, resulting in longer drying times and
increased energy usage.
The “Vent System Chart” provides venting requirements that
will help achieve best drying performance.
Number of
90° turns
or elbows
Type
of vent
Box/louvered
hoods
Angled
hoods
0 Rigid metal 64 ft. (20 m) 58 ft. (17.7 m)
1 Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m)
2 Rigid metal 44 ft. (13.4 m) 38 ft. (11.6 m)
3 Rigid metal 35 ft. (10.7 m) 29 ft. (8.8 m)
4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m)
Vent System Chart
INSTALL VENT SYSTEM
12" min.
(305 mm)
12" min.
(305 mm)
Install exhaust hood
1.
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
Connect vent to exhaust hood
2.
Vent must  t over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location
using straightest path possible. Avoid 90° turns. Use clamps
to seal all joints. Do not use duct tape, screws, or other
fastening devices that extend into interior of vent to secure
vent, because they can catch lint.
Number of
90° turns
or elbows
Type
of vent
Box/louvered
or angled hoods
0 Rigid metal 160 ft. (48.8 m)
1 Rigid metal 150 ft. (45.7 m)
2 Rigid metal 140 ft. (42.7 m)
3 Rigid metal 130 ft. (39.6 m)
4 Rigid metal 120 ft. (36.6 m)
5 Rigid metal 110 ft. (33.5 m)
Vent System Chart
(29" Wide Long Vent WED/WGD4870
and WED/WGD4975 Models Only)
20
Turn cold water off, remove
and replace rubber washer
1.
Turn cold water faucet off and remove washer inlet hose.
Remove old rubber washer from inlet hose and replace
with new rubber washer.
For non-steam models, skip to “Connect Vent.”
The dryer must be connected to the cold water faucet using
the new inlet hoses. Do not use old hoses.
CONNECT INLET HOSES
(Steam Models Only)
Tighten couplings
3.
Using pliers, tighten the couplings with additional
two-thirds turn.
NOTE: Do not overtighten. Damage to the coupling can result.
Attach short hose and
“Y” connector
2.
Attach 2 ft (0.6 m) inlet hose to cold water faucet. Screw
on coupling by hand until it is seated on faucet. Then attach
“Y” connector to end of the 2 ft (0.6 m) inlet hose. Screw
on coupling by hand until it is seated on “Y” connector.
Attach long hose to “Y”
connector and tighten couplings
4.
Attach dryer 5 ft (1.5 m) inlet hose ends to the “Y” connector.
Attach washer cold inlet hose to other side of “Y” connector.
Screw on coupling by hand until it is seated on connector.
Using pliers, tighten the couplings an additional two-thirds
turn.
NOTE: Do not overtighten. Damage to the coupling can result.
4"
(101 mm)
30
1
/4"
(768 mm)
Attach long hose to dryer  ll
valve and tighten coupling
5.
Attach other end of long hose to
ll valve at top of dryer back panel.
Screw on coupling by hand until
it is seated on  ll valve connector.
Using pliers, tighten the coupling
an additional two-thirds turn.
NOTE: Do not overtighten. Damage
to the coupling can result.
Turn on cold water faucet
Check that the water faucet is turned on.
6.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Whirlpool WED4850HW Guide d'installation

Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues