Sterilight S5Q-DWS Installation Instructions & Owner's Manual

Taper
Installation Instructions & Owner's Manual
Drinking Water Systems
S1Q-DWS, S2Q-DWS, S5Q-DWS
Installation Instructions &
Owner’s Manual
520030-RevE
Manufactured in Canada by:
Systéme de traitement de l’eau potable
S1Q-DWS, S2Q-DWS, S5Q-DWS
Instructions D’installation et
Manual D’utilisation
520030-RevE
®
2450 Business Park Dr., Vista, CA 92081 (760) 727-3711 (760) 727-4427
www.appliedmembranes.com [email protected]
Industry Leader in RO Expertise and Membrane Applications since 1983™
Distributed By:
®
2450 Business Park Dr., Vista, CA 92081 (760) 727-3711 (760) 727-4427
www.appliedmembranes.com [email protected]
Industry Leader in RO Expertise and Membrane Applications since 1983™
Distributed By:
Composantes ...................................1
Directives de sécurité ............................2
“ICE Ballast” additionnelles .......................3
Caractéristiques chimiques de l’eau ................4
Comment installer votre système de désinfection UV 4-6
Directives de fonctionnement et d’entretien ........ 6-7
Garantie du manufacturier ...................... 8-9
Spécifications .................................. 10
Table des maTières :
Parts ..........................................1
Safety Instructions ............................... 2
ICE Ballast Features .............................. 3
Water Chemistry ................................4
Installing Your UV Disinfection System ........... 4-6
Operating & Maintenance Instructions ............ 6-7
Manufacturer’s Warranty ....................... 8-9
Specifications .................................. 10
Table of ConTenTs:
Potential
Hazard
Safety Measures
UV Exposure Never illuminate UV Lamp outside of the UV Chamber.
Never look directly at illuminated UV Lamp, even when using protective gear.
Always use protective gear, including gloves and UV safety glasses.
If accidental exposure occurs, immediately cool affected area and consult physician.
Electrical Shock Disconnect power to system before performing any maintenance or repair.
There may be more than one source of power.
Impalement Never perform any physical inspection, repair or maintenance on UV Chamber unless UV
chamber has been isolated and depressurized.
Never service UV Lamps, Sleeves or associated hardware until depressurization of UV
chamber has been confirmed.
Hot chamber Allow UV Lamps, UV Chamber to cool for a minimum of 10 minutes before handling.
Cut or ingestion Ensure the quartz sleeve or lamp is not broken, cracked or damaged in any way when
handling equipment.
Scald from water When there is no water flow, the water in the chamber will become hot. To prevent scalding,
allow the system to cool before draining the system.
Fire Do not store any combustible or flammable material close to the system.
Hg Exposure The UV lamp contains mercury. If the lamp breaks, then avoid inhalation or ingestion of
the debris and avoid exposure to eyes and skin. Never use a vacuum cleaner to clean up a
broken lamp as this may scatter the spilled mercury. Obey local regulations and guidelines
for the removal and disposal of mercury waste.
Water leak Use proper plumbing materials to avoid potential material degradation from UV exposure.
Danger
potentiel
Des meaures de sécurité
Exposition aux
rayons UV
N’allumez jamais la lampe à rayons UV en dehors de la chambre UV.
Ne regardez jamais directement la lampe à rayons UV allumée, même si vous disposez d’un
équipement de protection.
Servez-vous toujours d’un équipement de protection, notamment des gants et des lunettes
de protection UV.
En cas d’exposition accidentelle, refroidissez immédiatement la zone affectée et consultez un
médecin.
choc électrique Débranchez l’alimentation du système avant d’effectuer toute opération d’entretien ou de
réparation.
Il peut exister plus d’une source d’alimentation.
Empalement Ne procédez jamais à une inspection physique, opération de réparation ou d’entretien de la
chambre UV, à moins que cette dernière soit isolée ou dépressurisée.
N’utilisez jamais les lampes à rayons UV, les manches ou tout matériel connexe avant d’avoir
la confirmation que la chambre UV est dépressurisée.
Échauffement de la
chambre
Laissez les lampes UV, la chambre UV refroidir pendant au moins 10 minutes avant toute
manutention.
Coupure ou ingestion En manipulant l’équipement, vérifiez que le manche ou la lampe à quartz ne présente pas de
fracture, fissure ou autre dommage de quelque nature.
Échaudures En l’absence d’écoulement d'eau, l'eau contenue dans la chambre devient chaude. Pour
éviter toute brûlure, laissez le dispositif refroidir avant de le vidanger.
Incendie Évitez de ranger tout matériau combustible ou inflammable à proximité du dispositif.
Exposition au
mercure
La lampe à rayons UV contient du mercure. Si la lampe se brise, évitez d’inhaler ou d’ingérer
des débris ou même d’exposer vos yeux et votre peau. N’utilisez jamais d’aspirateur pour
nettoyer une lampe brisée, car cela pourrait répandre le mercure déversé. Respectez la
réglementation et les directives locales en matière de nettoyage et d’élimination des déchets
de mercure.
Fuite d’eau Utilisez des matériaux de plomberie appropriés pour éviter une éventuelle dégradation
matérielle due à l'exposition aux rayons UV.
Prudence Conducteur de
terre
Attention –
courant
électrique
Fragile
Lunettes de
sécurité
symboles :
Caution Protective
Ground
Electrical
Warning Fragile
Eye Protection
symbols:
1
ParTs breakdown:
1
lisTe des PiéCes :
BALLASTS: (IEC POWER CORDS SOLD SEPARATELY):
BA-ICE-S....FOR ALL (100-240V/50-60HZ)UNITS
BALIMENTATION ÉLECTRIQUE :
(IEC POWER CORDS SOLD SEPARATELY):
BA-ICE-S....FOR ALL (100-240V/50-60HZ)UNITS
RETAINING NUT: RN-001.....FOR ALL UNITS
TORIQUE ÉROU D’IMMOBILISATION :
RN-001.....FOR ALL UNITS
QUARTZ SLEEVES:
QS-001.......FOR S1Q-DWS
QS-330.......FOR S2Q-DWS
QS-463.......FOR S5Q-DWS
GAINE DE QUARTZ :
QS-001.......FOR S1Q-DWS
QS-330.......FOR S2Q-DWS
QS-463.......FOR S5Q-DWS
LAMPS:
S287RL....FOR S1Q-DWS
S330RL....FOR S2Q-DWS
S463RL....FOR S5Q-DWS
LAMPE UV :
S287RL....FOR S1Q-DWS
S330RL....FOR S2Q-DWS
S463RL....FOR S5Q-DWS
REPLACEMENT CARTRIDGES:
AWP110.....SEDIMENT FILTER FOR S1Q-DWS AND S2Q-DWS
AWP110-2.....SEDIMENT FILTER FOR S5Q-DWS
REPLACEMENT CARTRIDGES:
AWP110.....SEDIMENT FILTER FOR S1Q-DWS AND S2Q-DWS
AWP110-2.....SEDIMENT FILTER FOR S5Q-DWS
IEC POWER CORDS FOR BALLASTS:
260010.....NORTH AMERICAN (NEMA 5-15P), 3-PRONG
GROUNDED
602637.....CONTINENTAL EUROPEAN (CEE 7/7), 2 PIN
WITH GROUND, “SCHUKO”
260012.....UK VERSION (BS 1363), 3 PRONG GROUNDED
(5 AMP FUSE)
260013.....AUSTRALIAN VERSION (AS 3112), 3 PRONG
GROUNDED
260019.....NO CONNECTOR, 3 WIRE, BARE LEADS
CORDONS ÉLECTRIQUES IEC POUR RÉGULATEURS :
260010.....NORTH AMERICAN (NEMA 5-15P), 3-PRONG
GROUNDED
602637.....CONTINENTAL EUROPEAN (CEE 7/7), 2 PIN
WITH GROUND, “SCHUKO”
260012.....UK VERSION (BS 1363), 3 PRONG GROUNDED
(5 AMP FUSE)
260013.....AUSTRALIAN VERSION (AS 3112), 3 PRONG
GROUNDED
260019.....NO CONNECTOR, 3 WIRE, BARE LEADS
REPLACEMENT CARTRIDGES:
C-01.....CARBON FILTER FOR S1Q-DWS AND S2Q-DWS
C-02.....CARBON FILTER FOR S5Q-DWS
REPLACEMENT CARTRIDGES:
C-01.....CARBON FILTER FOR S1Q-DWS AND S2Q-DWS
C-02.....CARBON FILTER FOR S5Q-DWS
O RINGS: 410867-R.....FOR ALL UNITS
JOINT TORIQUE :
410867-R.....FOR ALL UNITS
2
safeTy insTruCTions:
WARNING - to guard against injury, basic safety precautions should
be observed, including the following:
1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
2. CAUTION - Disconnect power before servicing.
3. DANGER - To avoid possible electric shock, special care should
be taken since water is present near electrical equipment.
Unless a situation is encountered that is explicitly addressed by
the provided maintenance and troubleshooting sections, do not
attempt repairs yourself, refer to an authorized service facility.
4. Carefully examine the disinfection system after installation. It
should not be plugged in if there is water on parts not intended
to be wet.
5. Do not operate the disinfection system if it has a damaged cord
or plug, if it is malfunctioning or if it is dropped or damaged in
any manner.
6. Always unplug the disinfection system before performing
cleaning or maintenance activities. Never yank the cord
to remove from an outlet; grasp the wall plug and pull to
disconnect.
7. Do not use this disinfection system for other than intended
use (potable water applications). The use of attachments not
recommended or sold by the manufacturer / distributor may
cause an unsafe condition.
8. Intended for indoor use only. Do not install this disinfection
system where it will be exposed to the weather or to
temperatures below freezing. Do not store this disinfection
system where it will be exposed to the weather. Do not store
this disinfection system where it will be exposed to temperatures
below freezing unless all water has been drained from it and the
water supply has been disconnected.
9. Read and observe all the important notices and warnings on the
water disinfection system.
10. If an extension cord is necessary, a cord with a proper rating
should be used. A cord rated for less Amperes or Watts than the
disinfection system rating may overheat. Care should be taken to
arrange the cord so that it will not be tripped over or pulled.
11. SAVE THESE INSTRUCTIONS.
Warning: The UV light given off by this unit can cause serious
burns to unprotected eyes and skin. Never look directly at an
illuminated UV lamp. When performing any work on the UV
disinfection system always unplug the unit first. Never operate the
UV system while the UV lamp is outside of the UV chamber.
Note: The UV lamp inside of the disinfection system is rated at an effective life of
approximately 9000 hours. To ensure continuous protection, replace the UV lamp annually.
WARNING - Always shut-off water flow and release water pressure
before servicing.
2
direCTives de séCuTiTé :
AVERTISSEMENT - Pour la protection contre les blessures on doit
toujours observer quelques mesures de sécurité fondamentales, dont les
suivantes:
1. LISEZ ET RESPECTEZ TOUTES LES DIRECTIVES DE SÉCURITÉ.
2. AVERTISSEMENT - Débrancher de la prise de courant avant toute
intervention d’entretien.
3. DANGER – Pour éviter les possibilités d’électrocution, il faut être
particulièrement prudent en raison de la présence d’eau près
d’appareils électriques. À moins qu’une situation rencontrée soit
expressément décrite par les sections d’entretien et de dépannage,
n’essayez pas d’effectuer des réparations vous même; consultez un
centre de réparation autorisé.
4. Examinez soigneusement le système de désinfection après son
installation. Il ne devrait pas être branché s’il y a de l’eau sur des
pièces qui ne devraient pas être mouillées.
5. Ne faites pas fonctionner le système de désinfection si son cordon ou
sa fiche sont abîmés, s’il ne fonctionne pas bien ou s’il est tombé ou
endommagé de quelque façon que ce soit.
6. Déconnectez toujours le système de désinfection et sa prise électrique
avant de commencer son nettoyage ou son entretien. Ne tirez jamais
sur le cordon pour le débrancher de la prise murale; saisissez la fiche
murale et tirez-la pour la débrancher.
7. N’utilisez pas ce système de désinfection à d’autres fins que celle
pour laquelle il est conçu (applications à eau potable). L’utilisation
d’accessoires qui ne sont ni approuvées, ni recommandés ni vendus
par le fabricant/distributeur peut créer une situation dangereuse.
8. Réservé à une utilisation à l’intérieur. N’installez pas ce système de
désinfection là où il sera exposé au climat ou à des températures
inférieures à 0 ˚C, à moins qu’il n’ait été vidé de toute l’eau qu’il
contient et qu’il ait été déconnecté de l’alimentation en eau.
9. Lisez et respectez tous les avertissements et toutes les mises en
garde sur le système de désinfection.
10. Si vous devez utiliser un cordon prolongateur, utilisez un cordon dont
les caractéristiques électriques sont appropriées. Un cordon dont les
caractéristiques d’ampérage ou de wattage sont inférieures à celles
du système de désinfection peut surchauffer. Il faut faire attention à
placer le cordon afin qu’il ne constitue pas un obstacle sur lequel on
peut trébucher ou qui peut être tiré.
11. CONSERVEZ CES DIRECTIVES.
Avertissement :
Note : La longévité prévue de la lampe UV à l’intérieur du système de désinfection est d’environ 9000
heures. Pour garantir une protection permanente, remplacer la lampe UV chaque année.
AVERTISSEMENT - Toujours arrêter le débit d’eau et dépressuriser le
système avant l’entretien.
3
3
Water quality is extremely important for the optimum performance of your
UV system. The following levels are recommended for installation:
Iron: < 0.3 ppm (0.3 mg/L)
Hardness*: < 7 gpg (120 mg/L)
Turbidity: < 1 NTU
Manganese: < 0.05 ppm (0.05 mg/L)
Tannins: < 0.1 ppm (0.1 mg/L)
UV Transmittance: > 75% (call factory for
recommendations on applications where UVT < 75%)
* Where total hardness is less than 7 gpg, the UV unit should operate
efficiently provided the quartz sleeve is cleaned
periodically. If total hardness is over 7 gpg, the water should be softened.
If your water chemistry contains levels in excess of those mentioned above,
proper pre-treatment is recommended to correct these water problems
prior to the installation of your UV disinfection system. These water quality
parameters can be tested by your local dealer, or by most private analytical
laboratories. Proper pre-treatment is essential for the UV disinfection
system to operate as intended.
waTer ChemisTry:
drinking waTer sysTems and ComPonenTs loCaTions:
System Location
Your DWS may be installed under a sink (S1Q-DWS and S2Q-DWS
only), in a basement or other location, depending on available space.
Do not install unit where temperatures fall below freezing; otherwise,
damage will result.
Faucet should be placed near the sink where drinking/cooking water
is normally required. A 2” diameter flat surface is required to mount
the faucet if an existing hole for a second faucet is not available. The
thickness of the mounting surface should not exceed 1-1/4”.
Feed water connection is accomplished with a 3/8” x 3/8” x 1/4”
adaptor. Locate this assembly as close to the DWS as possible.
Connect to a potable, cold water supply line only.
La qualité de l’eau est un facteur extrêmement important pour la
performance du système UV. On recommande les niveaux suivants pour
l’installation :
Fer : < 0,3 ppm (0,3 mg/L)
Dureté* : < 7 gpg (120 mg/L)
Turbidité : < 1 unité NTU
Manganèse : < 0,05 ppm (0,05 mg/L)
Tannins : < 0,1 ppm (0,3 mg/L)
Transmittance UV : > 75% (demander les recommandations du
fabricant pour les applications dans lesquelles la transmittance UV est
inférieure à 75%)
* Lorsque la valeur de dureté totale est inférieure à 7 gpg (120 mg/L), l’appareil
peut fonctionner efficacement si on nettoie périodique ment le manchon de quartz.
Lorsque la valeur de dureté totale est supérieure à 7 gpg (120 mg/L), on doit
soumettre l’eau à un adoucissement.
Si certains composants de l’eau sont présents en quantités supérieures à
celles indiquées ci-dessus, un pré-traitement approprié est recommandé
pour la correction de la composition de l’eau avant l’installation du systéme
de désinfection UV. Ces paramètres de qualité de l’eau peuvent être
examinés par votre revendeur local, ou par la plupart des laboratoires
analytiques privés. Il est essentiel pour que le système de désinfection UV
fonctionne traitement préparatoire approprié comme prévu.
CaraCTérisTiques Chimiques de leau :
emPlaCemenT du sysTème eT des ComPosanTs :
Emplacement du système
Votre système de désinfection de l’eau peut être monté sous un évier
(S1Q-DWS et S2Q-DWS seulement), au sous-sol ou ailleurs, selon
l’espace disponible. Pour éviter de l’endommager, ne le montez pas
dans un endroit où la température baisse sous le point de congélation.
Le robinet doit être placé près de l’évier où l’on prend l’eau de cuisson
et de boisson. Une surface plate de 2 po de diamètre est nécessaire
pour monter le robinet lorsqu’il n’y a pas déjà un trou pour un deuxième
robinet. L’épaisseur maximale de la surface de montage est
de 1 1/4 po.
Le raccordement de l’alimentation en eau se fait à l’aide d’un adaptateur
3/8 po x 3/8 po x 1/4 po. Placez cet assemblage le plus près possible
de votre système de désinfection. Raccordez le système uniquement à
une conduite d’eau potable froide.
4
4
Note: All plumbing must be completed in accordance
with local plumbing codes.
1. Faucet installation
If the sink has a sprayer it may be disconnected for faucet installation.
A pipe cap or plug will be necessary to seal the sprayer connection.
To make the faucet mounting hole (if sprayer or second hole is not used),
check below to make sure the drill does not interfere with anything under
your sink. Center punch a small indent at the desired faucet location.
(A 2” diameter flat surface is required, not exceeding 1 - 1/4”in thickness.)
Drill the required pilot hole for the chassis punch and tighten nut to cut the
desired hole size. Clean up sharp edges.The faucet should be positioned
so it empties into the sink and the spout swivels freely for convenience.
If the sink has a hole that can accommodate the faucet, no drilling is
required. Proceed with mounting the faucet.
insTalling your drinking waTer sysyTem:
Chrome Base Plate
Rubber Washer
Threaded Nipple
Flat Washer
Star Washer
Hex Nut
Faucet Adaptor
Figure 2
Remarque : Tous les raccords de plomberie doivent être faits
conformément au code de plomberie en vigueur dans votre région.
1. Installation du robinet
Si l’évier a une douchette, celle-ci peut être déconnectée pour permettre
l’installation du robinet. Il faut alors poser un bouchon ou capuchon de tuyau
pour sceller la connexion de la douchette.
Pour faire le trou de montage du robinet (lorsqu’on n’utilise pas la douchette
ou s’il n’y a pas de deuxième trou), vérifiez que la mèche de la perceuse
n’entrera pas en contact avec quelque chose sous l’évier. Utilisez un
poinçon pour marquer le centre du trou pour le robinet. (Il faut une surface
plate de 2 po de diamètre d’une épaisseur maximale de 1 1/4 po.)
Percez l’avant-trou nécessaire pour l’emporte-pièce et serrez l’écrou pour
couper le trou à la taille désirée. Supprimez les ébarbures. Le robinet doit
être placé de façon à ce qu’il se déverse dans l’évier et que le bec pivote
librement pour commodité. Aucun perçage n’est nécessaire lorsqu’il y a
déjà un trou où installer le robinet. Passez au montage du robinet.
insTallaTion du sysTème deau PoTable
Plaque chromée
Rondelle de caoutchouc
Mamelon leté
Rondelle plate
Rondelle en étoile
Écrou à six pans
Adaptateur de robinet
Figure 2
2. Mounting the faucet
Disassemble hardware from the threaded nipple, except for chrome base
plates and rubber washers. (Rubber washers may be replaced with bead of
plumber’s putty for neater appearance.) Feed the threaded nipple through
sink or counter mounting hole and orient the faucet. From below sink or
counter, assemble the white spacer flat washer and hex nut on threaded
nipple and tighten by hand. (Open end up; open side toward air gap). After
checking faucet orientation, tighten with a wrench until secure.
3. Installing the Water Supply Adapter
Typical installation requires bringing cold water supply to the Drinking Water
System. This can be done using the 3/8”x3/8”x1/4” adapter (supplied) or
any other adapter that can be obtained from your local plumbing store.
Recommendations for installing an adapter:
1. Turn off cold water inlet supply line. If cold water line does not have a
shut off valve under the sink, one should be installed.
2. Turn on the cold water faucet and allow all water to drain from the line.
3. Install the Water Supply Adapter in line with the main faucet using
appropriate fittings.
4. Ensure outlet of adapter is oriented to allow easy connection to the DWS
with the supplied 1/4” tube.
5
5
2. Montage du robinet
Démontez les fixations du mamelon fileté, sauf pour la plaque de base
chromée et les rondelles de caoutchouc. (Vous pouvez remplacer les
rondelles de caoutchouc par un filet de mastic de plomberie pour améliorer
l’apparence.) Enfilez le mamelon fileté dans le trou de l’évier ou du comptoir
et orientez le robinet. Sous l’évier ou le comptoir, montez la rondelle plate
blanche et l’écrou à six pans sur le mamelon fileté et serrez à la main
(bout ouvert vers le haut; côté ouvert vers l’ouverture). Après avoir vérifié
l’orientation du robinet, serrez solidement avec une clé.
3. Pose de l’adaptateur d’alimentation en eau
L’installation typique exige d’aporter une alimentation en eau froid chez
the système de traitement de l’eau potable. Ceci peut être fait en utilisant
l’adaptateur inclus (3/8”x3/8”x1/4”), ou un autre adaptateur obtenu par la
magasin de plomberie local.
Les recommandations pour l’installation avec l’adaptateur:
1. Coupez l’alimentation en eau froide. Si le tuyau d’alimentation sous l’évier
n’a pas de soupape d’arrêt, posez-en une.
2. Ouvrez le robinet d’eau froide et laissez toute l’eau s’évacuer de
la canalisation.
3. Faire installer l’alimentation de l’eau en ligne avec le robinet principal en
utilisant les raccords appropriés.
4. Assurer que le sortie d’adaptateur est orientée facilement à le système
DWS avec le tube inclus (1/4”).
Figure 3 : DWS Unit Installation
Faucet Adaptor
(7/16 UNS to 3/8” tube)
Adaptor
3/8 - 3/8 - 1/4”
1/4“
Connection
from water
supply
F
aucet
F
F
A
da
p
tor
(
7
/
1
6
UNS to 3/8” tube
)
Ada
p
tor
3
/
8
- 3/8 - 1/4”
1/4
onn
e
cti
on
f
r
om
w
at
er
w
w
s
upp
ly
Figure 3 : Installation du système de désinfection
Adaptateur
d’alimentation
d’eau 3/8 x
3/8 x 1/4 Connexion
1/4 po
de l’alimentation
en eau
Adaptateur de robinet
(7/16 UNS à tuyau 3/8 po)
A
da
p
tateu
r
d
’alimentati
on
d
eau
3
/8 x
3
/8 x 1/4
Co
nnexi
on
1/
4 p
o
d
e l
alimentatio
n
e
n
e
au
Adaptateur de robine
t
(
7/16 UNS à tuyau 3/8
p
o
)
6
6
1. For shipping purposes, the UV lamp is shipped in a separate cardboard
tube. Carefully remove the UV lamp from the shipping tube being careful
not to touch the “glass” portion with your fingers. Insert the UV lamp into
the quartz sleeve and chamber making sure the connection end is inserted
last. Mount the disinfection system to the wall or cabinet.
2. If the disinfection system is to be hard plumbed, make sure you leave
enough clearance in front of the lamp connector to facilitate lamp service
(a length equal to the length of the unit should suffice).
3. Mount the system to the wall using the two mounting holes in the back of
the disinfection system with appropriate fastening devices. (See Fig. 3)
4. Final tubing connections:
With all components in place, complete final tubing connections using
these guidelines:
a. Cut tubing to desired length using square cuts and
proper cutting device
b. Make no sharp bends
c. Keep tubing from the supply line to the unit and faucet as short as
practical for good flow
d. Connect tubing from faucet to DWS
e. Connect tubing from water supply adaptor to DWS
5. Prior to connecting the power source, check all connections to ensure that
they are indeed secure, turn on water supply and check for any leaks.
If satisfied that there are no leaks, proceed with the following steps.
6. The power source provided with your disinfection system must be located
within (5) feet of an electrical outlet. DO NOT USE AN OUTLET THAT
CAN BE SWITCHED OFF (IE. A WASTE DISPOSAL OUTLET). Install the
UV lamp as outlined on pages 8, 9. Plug the ballast into the outlet and
ensure the POWER-ON LED is illuminated. The audible ballast will enter a
self test mode when power is first applied to verify ballast operation.
Note: If ballast enters alarm condition, power must be removed for 30 seconds to
allow ballast to reset.
Note: As the system requires time to reach its full operating capacity,please allow
the disinfection system to operate 3 - 5 minutes prior to using the water from the
unit. In addition, to clear any air or debris from the system, open the faucet and
allow water to run through the disinfection system for 2 - 3 minutes (when using
an RO application, run the water for 30 - 45 seconds).
1. La lampe UV est expédiée séparément, dans un tube de carton. Retirez
prudemment la lampe UV du tube d’emballage en veillant à ne pas toucher la partie
en « verre » avec les doigts. Insérez la lampe UV dans la gaine de quartz et la
chambre d’irradiation, l’extrémité comportant le connecteur vers le haut. Montez le
système de désinfection sur un mur ou une armoire.
2. Si le système de désinfection est installé en permanence, veillez à laisser assez
d’ espace libre devant le connecteur de la lampe pour pouvoir remplacer la lampe
(il suffit d’une longueur égale à la longueur de l’appareil).
3. Montez le système sur le mur en insérant des fixations appropriées dans les deux
trous de montage à l’arrière du système. (Voir la figure 3.)
4. Raccordement à la tuyauterie :
Une fois tous les composants en place, raccordez les canalisations en respectant
les directives suivantes.
a. Coupez les tuyaux à la longueur désirée en faisant des coupes droites à
l’aide d’un outil de coupe approprié.
b. Ne pliez pas excessivement les tuyaux.
c. Veillez à ce que le tuyau raccordant l’alimentation en eau à l’appareil et au
robinet soit le plus court possible pour avoir un bon débit.
d. Raccordez le tuyau du robinet à l’appareil de désinfection.
e. Raccordez le tuyau de l’adaptateur de l’alimentation en eau à l’appareil
de désinfection.
5. Avant de brancher l’appareil sur la prise de courant, vérifiez que toutes les
connexions ont été correctement exécutées. Ouvrez l’alimentation en eau et
recherchez les fuites. S’il n’y a pas de fuite, passez aux étapes suivantes.
6. La source d’ alimentation électrique fournie avec le systéme de désinfection doit
être située à moins de 5 pi d’ une prise de courant. NE PAS UTILISER UNE PRISE
DE COURANT DESTINÉE À UN BROYEUR À DÉCHETS, DONT L’ALIMENTATION
PEUT ÊTRE CONTRÔLÉE PAR UN INTERRUPTEUR. Faire installer la lampe
UV comme indiquer sur les pages 8 & 9. Le connecteur comporte un repère
de positionnement qui empêche un branchement incorrect. Veiller à ce que le
connecteur soit parfaitement enfoncé sur la lampe UV. Faire glisser le connecteur
par dessus l’écrou de retenue en aluminium. Branchez le régulateur dans la prise
et vérifiez que la diode électroluminescente (DEL) POWER-ON est allumée. Le
régulateur audible entrera dans un mode de test automatique lorsqu’il sera mis
sous tension pour en vérifier le bon fonctionnement.
Note : si le régulateur passe en condition d’alarme, coupez l’électricité pendant
30 secondes pour permettre au régulateur de se réinitialiser.
Note : Comme le système n’atteint le maximum de sa capacité de traitement qu’après
quelques instants, laisser le systéme de désinfectionfonctionner pendant 3 à 5 minutes
avant d’ utiliser l’eau traitée par l’appareil. De plus, pour éliminer tous débris ou résidu
d’air du système, ouvrir le robinet et laisser l’eau circuler à travers le systéme de
désinfection pendant 2 à 3 minutes (dans le cas d’ une application avec osmose inverse,
laisser l’ eau couler pendant 30 à 45 secondes).
4. DWS Unit Installation
7
7
4. Installation de l’unité de désinfection
To sanitize system follow these procedures:
1. At all times during this process, make sure the UV unit and lamp is
turned on and operational.
2. Shut off the feed water valve.
3. Remove pre-filter cartridges from housings.
4. Use 5.25% unscented bleach such as Clorox.
DO NOT use hydrogen peroxide.
5. Add one cap full (2 tsp or 10 ml) of bleach to each pre-filter housing.
6. Slowly open the feed water line and allow cold water to run.
7. Close faucet as soon as you smell chlorine dripping out of spout.
8. Let system stand for approximately 15 minutes.
9. After fifteen minutes flush the chlorine solution from the system until
no chlorine smell is detectable
10. Reinstall the filter cartridges in the appropriate filter housings. Tighten
with wrench.
Note: Be sure to check o-rings are in place and are lubricated with silicone
based lubricant when installing cartridges in filter housings.
1. As the system requires time to reach its full operating capacity, please
allow the disinfection system to operate 3 - 5 miniutes prior to using the
water from the unit. In addition, to clear any air or debris from the
system, open the faucet and allow water to run through the disinfection
system for 2-3 minutes.
2. Close faucet and re-inspect system for leaks.
OPERATION
• Always disconnect power before performing any work on the
disinfection system.
• Regularly inspect your disinfection system to ensure that the power
indicators are on and no alarms are present.
• Replace the UV lamp annually (or biennially if seasonal home use)
to ensure maximum disinfection.
• Always drain the reactor chamber and filter housings when closing a
seasonal home or leaving the unit in an area subject to freezing
temperatures.
saniTizing insTruCTions:
CondiTioning filTer and CheCking oPeraTion:
8
Marche à suivre pour désinfecter le système :
1. Assurez-vous que l’appareil UV et la lampe sont allumés et fonctionnent
pendant toutes les étapes de la désinfection.
2. Fermez la soupape d’alimentation en eau.
3. Retirez les cartouches de filtration des boîtiers.
4. Utilisez un javellisant non parfumé de 5,25 % comme le Clorox.
N’UTILISEZ PAS du peroxyde d’hydrogène.
5. Ajoutez un capuchon complet (2 c. à thé ou 10 ml) de javellisant dans
chaque boîtier de filtration.
6. Ouvrez lentement l’alimentation en eau et laissez couler l’eau froide.
7. Fermez le robinet dès que vous détectez l’odeur du chlore au robinet
d’eau potable.
8. Laissez le système se désinfecter pendant environ 15 minutes.
9. Au bout de quinze minutes, vidangez la solution de chlore du système
en faisant couler l’eau jusqu’à ce que vous ne puissiez plus détecter
l’odeur du chlore.
10. Replacez les cartouches de filtration dans les boîtiers appropriés. Serrez
avec une clé.
Remarque : Veillez à ce que les joints toriques soient en place et lubrifiés
avec un lubrifiant à la silicone lorsque vous remplacez les cartouches
de filtration.
1. Le système exige quelques minutes avant de fonctionner à pleine
capacité. Laissez le système de désinfection fonctionner de 3 à 5
minutes avant d’utiliser l’eau qu’il produit. De plus, pour évacuer l’air et
les débris du système, ouvrez le robinet et faites couler l’eau pendant
2 à 3 minutes pour vidanger le système.
2. Fermez le robinet et examinez de nouveau les raccords pour des fuites.
désinfeCTion du sysTème
FONCTIONNEMENT
Débranchez toujours l’alimentation électrique avant de faire l’entretien du
système de désinfection.
Inspectez régulièrement le système de désinfection pour assurer que les
témoins de tension sont allumés et qu’aucune alarme n’est activée.
Remplacez la lampe UV une fois par année (tous les deux ans dans les
résidences saisonnières) pour assurer une désinfection maximale.
• Vidangez toujours la chambre d’irradiation et les boîtiers du filtre lorsque
vous fermez une maison saisonnière ou avant de laisser le système dans
un endroit où il peut être exposé à une température inférieure au point
de congélation.
CondiTionnemenT du filTre eT vérifiCaTion du
fonCTionnemenT
8
oPeraTing & mainTenanCe insTruCTions:
CAUTION: PRIOR TO PERFORMING ANY WORK ON THE
DISINFECTION SYSTEM,
ALWAYS DISCONNECT THE POWER SUPPLY FIRST.
UV Lamp Replacement:
NOTE: RESET LAMP LIFETIMER AFTER LAMP REPLACEMENT (PG 11).
Refer to www.lamprecycle.org for lamp disposal.
1. Lamp replacement is a quick and simple procedure
requiring no special tools. The UV lamp must be
replaced after 9,000 hours of continuous operation
(approximately one year) in order to ensure adequate
disinfection.
2. Disconnect main power source and allow the unit
to power down. Remove the lamp connector by
squeezing the plastic locking tabs on the side of the
connector. Remove connector and lamp from the
reactor chamber and lamp connector base. Separate
the lamp from the connector (Figure 2A). Do not twist
the lamp from the connector, simply slide the two
apart. Avoid touching the lamp on the glass portion.
Handling the lamp at the ceramic ends is acceptable,
however if you must touch the lamp glass, please use
gloves, or a soft cloth. Fully remove the lamp from
the reactor chamber being careful not to angle the
lamp as it is removed from the chamber. If the lamp
is removed on an angle, pressure will be applied on
the inside of the quartz sleeve, causing the sleeve to
fracture.
3. To install a new lamp, first remove the lamp from its
protective packaging, again being careful not to touch
the lamp glass itself. Carefully insert the lamp into the
reactor vessel (actually inside the quartz sleeve) (Figure
2B). Insert the lamp fully into the chamber leaving
about two inches of the lamp protruding from the
chamber. Next, attach the connector to the UV lamp.
The connector is “keyed” and will only allow correct
installation in one position. Ensure the connector is fully
seated onto the UV lamp (Figure 2C).
4. Once the lamp is fully seated on the connector,
slide the connector over the retaining nut. and lamp
connector base. Push the lamp connector and lamp
connector base together until an audible click is heard.
9
WARNING: ALWAYS SHUT-OFF WATER FLOW AND RELEASE WATER PRESSURE
BEFORE SERVICING.
REMARQUE - NE PAS OUBLIER DE DÉBRANCHER
D’ABORD L’ALIMENTATION ÉLECTRIQUE AVANT
D’EXÉCUTER LES TRAVAUX SUR LE STÉRILISATEUR.
Remplacement de la lampe UV:
Noter: Remettre le remise de la minuterie après replacement de la
lampe (pg 11).
Référer à www.lamprecycle.org pour la disposition de la lampe.
1. Le remplacement de la lampe est une opération simple et
rapide, qui ne nécessite aucun outillage spécial. Pour garantir
une désinfection adéquate, on doit remplacer la lampe UV à
intervalles de 9,000 heures de service continu (environ 1 fois
par an).
2. Interrompre l’alimentation électrique et laisser le processus de
mise hors-tension s’exécuter pendent 30 secondes. Enlever
le connecteur par faire compression des onglets verrouillage
sûr le côté du connecteur. Enlever le connecteur et retirer la
lampe de la chambre du réacteur et base de le connecteur de
la lampe. Lorsque la lampe devient visible, séparer la lampe du
connecteur (Figure 2A). Il suffit de séparer les deux composants
– ne pas effectuer un mouvement de torsion entre la lampe et
le connecteur. Éviter de toucher la surface de verre de la lampe.
Il est acceptable de manipuler la lampe par les extrémités de
céramique; cependant, s’il est nécessaire de toucher le tube
de verre, porter des gants ou utiliser un linge doux. Retirer
complètement la lampe de la chambre du réacteur; en veillant à
ne pas incliner la lampe par rapport au réacteur; si la lampe est
inclinée, une pression est exercée à l’intérieur du manchon de
quartz, et ceci provoquera le bris du manchon.
3. Pour l’installation d’une lampe neuve, retirer d’abord la lampe
de son emballage de protection; veiller encore à ne pas toucher
la surface de verre de la lampe. Insérer prudemment la lampe
dans le réacteur (en fait, à l’intérieur de la gaine de quartz) (Figure
2B). Insérer complètement la lampe dans le réacteur – ne laisser
la lampe dépasser que de deux pouces hors de la chambre
du réacteur. Ensuite, placer le connecteur sur la lampe UV le
connecteur comporte un repère de positionnement qui empêche
un branchement incorrect. Veiller à ce que le connecteur soit
parfaitement enfoncé sur la lampe UV (Figure 2C).
4. Lorsque la connexion est parfaite entre le connecteur et
la lampe, faire glisser le connecteur par-dessus l’écrou de
retenueet base de le connecteur de la lampe. Poussez sûr
la base du connecteur de la lampe et aussi le connecteur du
lampe, aussitôt qu’un clic audible est entendu.terre située sur la
chambre du réacteur.
insTruCTions d’uTilisaTion eT d’enTreTien :
9
AVERTISSEMENT - TOUJOURS ARRÊTER LE DÉBIT D’EAU ET DÉPRESSURISER
LE SYSTÈME AVANT L’ENTRETIEN.
FIGURE 2A
FIGURE 2A
FIGURE 2B
FIGURE 2B
FIGURE 2C
FIGURE 2C
5. If the water contains any hardness minerals (calcium or magnesium),
iron or manganese, the quartz sleeve will require periodic cleaning. To
remove the quartz sleeve, first remove the UV lamp as outlined in step
1-4 then perform the following steps:
a) Shut off water supply and drain all lines.
b) Remove the lowest connection on the
disinfection system and drain the UV
chamber (use a small bucket under the unit
to prevent a spill).
c) Remove retaining nuts from chamber
(Figure 3A), checking for the free floating
spring inside sleeve at the opposite end to
the lamp connection (do not allow quartz
sleeve to fall).
d) Carefully remove o-rings from the quartz
sleeve. As the o-ring may tend to adhere
to the quartz sleeve, it is recommended to
replace the o-rings annually.
e) Clean the quartz sleeve with a cloth soaked
in CLR, vinegar or some other mild acid and
then rinse.
f) Re-assemble the quartz sleeve with spring
in the UV chamber allowing the sleeve to
protrude an equal distance from both ends
of the UV chamber (Figure 3B).
g) Wet the o-rings and slide onto each end
of the quartz sleeve and reassemble the
retaining nuts (hand tight is sufficient).
h) Re-tighten all connections, turn on water
and check for leaks.
I) Re-install the UV lamp and lamp connector
as per prior instructions.
j) Plug in ballast and verify the POWER-ON
LED is illuminated and ballast power-up
sequence operates.
Note: If the system is put on a temporary by-pass or if it becomes contaminated
after the disinfection system, it will be necessary to shock the system with
household bleach for a full 20 minutes before resuming the use of the water.
10
5. Si l’ eau contient des composés minéraux comme calcium ou magnésium (eau dure),
fer ou manganèse, la gaine de quartz nécessitera un nettoyage périodique. Pour
retirer la gaine de quartz, retirer d’ abord la lampe UV comme ceci est décrit à l’
étape 1-4, et exécuter les étapes suivantes :
a) Fermer l’ arrivée d’ eau, et purger toutes les
canalisations.
b) Ouvrir la connexion la plus basse sur le
stérilisateur, et drainer la
chambre d’ irradiation UV (placer un petit seau sous
l’ appareil pour éviter de répandre l’ eau).
c) Enlever les écrous de retenue des deux extrémités
de la chambre du réacteur, (Figure 3A), tout en
vérifiant le ressort flottant qui se retrouve dans le
manchon de quartz au bout opposé du connecteur.
(Veiller à ne pas laisser tomber lemanchon de
quartz).
d) Séparer prudemment les joints toriques de la gaine
de quartz. Comme les joints toriques peuvent
adhérer à la gaine de quartz, on recommande leur
remplacement annuel.
e) Nettoyer la gaine de quartz avec un linge imbibé
de CLR, vinaigre ou d’ un autre acide faible, puis
rincer.
f) Réinstaller la gaine de quartz dans la chambre d’
irradiation UV; veiller à ce que la gaine dépasse
de la même distance aux deux extrémités de la
chambre (Figure 3B).
g) Humidifier les joints toriques et glisser les joints
à chaque extrémité du manchon de quartz.
Réinstaller les écrous (le serrage à la main est
suffisant). Utilisez les nouveaux joints toriques
fournis
h) Resserrer toutes les connexions; ouvrir l’ arrivée d’
eau; inspecter pour rechercher les fuites.
i) Réinstaller la lampe UV et le capuchon de
caoutchouc conformément aux instructions
précédentes.
Note: Si le système est contourné temporairement ou s’il y a contamination après le
système de désinfection, il sera nécessaire de faire un traitement choc au javellisant
domestique, pendant un bon 20 minutes, avant de consommer l’eau de nouveau.
10
FIGURE 3A
FIGURE 3B
FIGURE 3A
FIGURE 3B
11
Operation:
Basic Systems incorporating BA-ICE-S controller:
178973
To be used with
Model S Series only.
1. Lamp life remaining (days):
The controller tracks the number of days of operation of the lamp and the
controller. The default screen will display the total lamp life remaining (in days).
The controller will count down the number of days remaining until the lamp
requires changing (365 days to 1 day). At “0” days, the controller will display
on the display and supply an intermittent audible chirp (1 second on, 5 seconds off),
indicating the need to change the lamp.
DEFERRAL - Once the A3” or end of lamp life message is shown on the LED screen, the
audible alarm can be deferred up to 4 separate times. The delay is designed to allow you
time to address the alarm while you obtain a new UV lamp. This can be done by simply
depressing the timer reset button for 5 seconds, which is located on the left side of the
controller. Each time the timer reset button is pressed the
controller alarm is deferred seven days. Once the final 7 day
deferral has been reached the alarm can only be silenced by
changing the UV lamp and manually resetting the controller timer.
To do this please follow the step by step instructions below:
RESETTING LAMP LIFE:
1. disconnect power supply from controller
2. disconnect lamp connector and remove expired lamp from the
reactor chamber (refer to www.lamprecycle.org for lamp disposal)
3. install new UV lamp and re-connect it to lamp connector (refer to page 8)
4. re-connect lamp connector to lamp connector base
5. hold down the timer reset button while reapplying power to the controller until you see
“rSEt”, then release
6. 5 second delay will occur until you hear an audible tone & LED display will read once again
Once you hear the tone, let go of the reset button and the counter will be reset. Even
though the alarm on the system can be deferred for a period of time, it is important to
address each and every alarm condition as they are indicating that there is a potential
problem with the system and should be remedied.
2. Total days of operation:
The controller also displays the total running time of the controller. To obtain this reading,
press the push-button once. The total running time of the controller will be numerically
displayed in days. This information will remain displayed for ten seconds and
will then revert back to the lamp life remaining default screen. It should be
noted that this value cannot be reset.
3. Lamp failure (blank screen):
When the system recognizes LAMP FAILURE (no current running through the lamp), the
4-segment display will be blank (no default LAMP LIFE REMAINING screen) and the system
will supply an intermittent audible tone (1 second on,1 second off). The system
will remain in this state, until this condition is remedied.
Fonctionnement :
178973
To be used with
Model S Series only.
1. Durée d’opération résiduelle de la lampe (en jours) :
Le contrôleur prend note du nombre de jours d’utilisation de la lampe et du
contrôleur. La valeur par défaut de l’afficheur indiquera la durée d’opération
résiduelle de la lampe, en nombre de jours. Le contrôleur compte à rebours le
nombre de jours qui restent avant que la lampe nécessite un changement (de 365 jours à 1
jour). Une fois à “zéro” (0), le contrôleur affichera et émettra un signal sonore intermittent
(à toutes les cinq (5) secondes) indiquant que la lampe doit être changée.
INTERRUPTION - Lorsque le code “A3” ou message indiquant la fin de la durée d’opération de
la lampe apparaît à l’écran DEL, vous pouvez interrompre l’émission de l’alarme sonore, jusqu’à
quatre (4) fois, en appuyant tout simplement sur le bouton de
remise de la minuterie situé à gauche du contrôleur. Chaque fois
que vous appuyez sur le bouton de remise de la minuterie, l’alarme
du contrôleur est interrompue pendant sept (7) jours. Après avoir
interrompu l’alarme pour une quatrième fois, la seule façon de
réduire l’alarme au silence est de changer la lampe et de remettre
la minuterie du contrôleur à l’état initial, à la main. Pour remplacer
la lampe, veuillez suivre les étapes ci-dessous une à une :
RÉINITIALISATION DU COMPTEUR DE LA DURÉE RÉSIDUELLE DE LA LAMPE
1. Débrancher l’alimentation électrique du contrôleur.
2. débrancher le connecteur de la lampe et retirer la lampe usée de la chambre du réacteur
(visitez www.lamprecycle.org pour disposition des lampes usées).
3. Installer la nouvelle lampe UV et la reconnecter au connecteur de lampe (pour instructions
voir la page 8).
4.reconnecter le connecteur de la lampe avec la base du connecteur de la lampe.
5. Appuyer sur le bouton de remise de la minuterie pendant que vous rebranchez l’alimentation
électrique au contrôleur et relâcher le bouton seulement lorsque vous voyez ‘’rSEt’’ s’afficher
à l’écran.
6. Après un délai de cinq (5) secondes, un avertisseur sonore se fera entendre et l’écran DEL
affichera à nouveau .
Dès que vous entendrez le signal sonore, relâcher le bouton et le compteur sera remis à l’état
initial. Même si l’alarme peut être interrompue pour un certain temps, il est très important de
tenir compte de toutes les conditions d’alarme puisqu’elles indiquent qu’il y a un problème
potentiel avec le système qui doit être rémédié.
2. Nombre total de jours d’activité :
Le contrôleur peut aussi afficher la durée totale de fonctionnement du contrôleur.
Pour l’obtenir, appuyer une fois sur le bouton de remise de la minuterie et la
durée totale de fonctionnement (nombre de jours) s’affichera. Cette valeur
restera affichée pendant 10 secondes avant de retourner à la valeur par défaut :
la durée d’opération résiduelle de la lampe. Veuillez prendre note que cette valeur ne peut pas
être remise à zéro.
3. Défaillance de la lampe (absence d’affichage) :
Lorsque le système détecte une défaillance de la lampe (le courant ne passe pas dans la lampe),
l’afficheur à quatre segments sera blanc (la valeur par défaut de la durée d’opération résiduelle
de la lampe n’apparaîtra pas) et le système émettra un signal sonore intermittent
(à toutes les deux secondes), tant et aussi longtemps que vous n’aurez pas
remédié à la situation.
Systèmes de base avec contrôleur BA-ICE-S
11
12
12
CarTridge rePlaCemenT:
It is recommended to change the filter cartridges regularly, approximately
3-4 times per year depending on water quality and usage. A gradual drop
in water pressure after the filtration device is an indication that the filter
cartridges are nearing the end of their useful life. To change the cartridges,
please follow the following procedure:
Note: Prior to performing any work on the drinking water system,
ALWAYS DISCONNECT THE POWER SUPPLY FIRST.
1. Shut-off the water flow to the unit via the main line shut-off valve.
2. Remove the filter sumps from the unit by turning counter-clockwise until
the sump falls free from the head (be careful as the sumps will be full of
water and they will be heavy).
3. Discard the used cartridge and clean the sump housing as required.
Make sure to thoroughly rinse the sump with water to get rid of any
cleaning agents.
4. Ensure the sump o-ring is lubricated with silicone base lubricant. Install
the new cartridge in the reverse procedure as stated above turning the
sump clockwise until the sump is tight. DO NOT OVER TIGHTEN.
5. Plug UV unit into the applicable outlet and power-up system.
6. Slowly turn on the water supply and allow any air that may now be
present to bleed off from the system. This can easily be accomplished by
partially opening a nearby faucet. Once the water runs without the
presence of any air, return the system to use.
remPlaCemenT de la CarTouChe
Il est conseillé de changer régulièrement les cartouches de filtration, de
trois à quatre fois par année, selon la qualité de l’eau et la consommation
d’eau. Une baisse graduelle de la pression de l’eau après l’unité de filtration
est une indication que les cartouches de filtration approchent de la fin de
leur durée utile. Suivez les étapes ci-dessous pour remplacer les cartouches:
Remarque : RETIREZ TOUJOURS LA FICHE DE LA PRISE DE COURANT
AVANT de faire tout entretien du système de désinfection.
1. Coupez l’alimentation en eau du système à la soupape d’arrêt principale.
2. Retirez les boîtiers des filtres en les tournant dans le sens contraire aux
aiguilles d’une montre (attention – les boîtiers sont remplis d’eau et ils
sont lourds).
3. Jetez la cartouche usée et nettoyez le boîtier du filtre selon les besoins.
Assurez-vous de rincer complètement le boîtier pour éliminer toute trace
de l’agent de nettoyage.
4. Assurez-vous que le joint torique du boîtier est lubrifié avec un lubrifiant
à la silicone. Installez la nouvelle cartouche en inversant les étapes
précédentes et en tournant le boîtier dans le sens des aiguilles d’une
montre jusqu’à ce qu’il soit serré. NE SERREZ PAS EXCESSIVEMENT.
5. Branchez le module UV sur la prise de courant pour mettre le système
sous tension.
6. Ouvrez lentement l’alimentation en eau et laissez l’air s’échapper du
système en ouvrant partiellement un robinet. Lorsqu’il n’y a plus
de bulles d’air dans l’eau, remettez le système en service.
13
garanTie du fabriCanT :
Notre engagement
VIQUA s’engage à assurer que votre expérience avec ses produits et son organisation
dépasse vos attentes. Nous avons fabriqué votre système de purification aux UV selon
les normes les plus élevées de qualité et nous sommes fiers de vous compter parmi
nos clients. Si vous avez besoin de soutien ou avez des questions au sujet de votre
système, veuillez contacter notre équipe d’assistance technique au 1.800.265.7246 ou à
tec[email protected] et nous nous ferons un plaisir de vous venir en aide. Nous
espérons sincèrement que vous apprécierez les bienfaits d’une eau potable propre et
sûre après l’installation de votre système de purification Sterilight®.
Modalités de réclamation en vertu de la garantie
REMARQUE : Pour maximiser le rendement de désinfection et la fiabilité de votre
produit Sterilight®, le système doit être de taille appropriée et être installé et entretenu
correctement. Le manuel du propriétaire renferme des renseignements sur les paramètres
de qualité essentiels de l’eau et les exigences en matière d’entretien de votre système.
Veuillez contacter votre revendeur si votre système a besoin de réparations ou de pièces
de rechange en vertu de cette garantie. Communiquez avec notre équipe d’assistance
technique au 1.800.265.7246 ou par courriel à [email protected] si vous ne
savez pas si un problème ou une défaillance de votre matériel est couvert par la garantie.
Nos techniciens spécialisés vous aideront à dépanner le problème et à déterminer la
solution. Vous devez fournir le numéro de modèle (type de système), la date d’achat,
le nom du revendeur chez qui vous avez acheté votre système Sterilight® (« revendeur
d’origine »), ainsi qu’une description du problème.
Pour établir votre preuve d’achat lors d’une réclamation en vertu de la garantie, il vous
faudra votre facture originale ou avoir complété et retourné votre carte d’inscription du
produit ou vous être inscrit en ligne.
Protection spécifique de la garantie
La couverture de cette garantie ne s’applique qu’aux produits des gammes Sterilight®
Copper, Silver, Cobalt et Platinum et est assujettie aux conditions et restrictions figurant
sous « Conditions et restrictions générales » ci-dessous.
Garantie limitée de sept ans pour la chambre UV Sterilight®
VIQUA garantit que la chambre UV du système Sterilight® est exempte de toute
défectuosité de matériel et de fabrication pendant une période de sept (7) ans après la
date d’achat. Au cours de cette période, VIQUA réparera ou remplacera, comme bon
lui semble, les chambres UV Sterilight® défectueuses. Veuillez retourner la pièce
défectueuse à votre revendeur qui traitera votre réclamation.
Garantie limitée de deux ans pour les composants matériels et électriques
VIQUA garantit que les composants électriques (bloc d’alimentation) et matériels sont
exempts de toute défectuosité de matériel et de fabrication pendant une période de deux
(2) ans après la date d’achat. Au cours de cette période, VIQUA réparera ou remplacera,
comme bon lui semble, les pièces défectueuses couvertes par la garantie. Veuillez
retourner la pièce défectueuse à votre revendeur qui traitera votre réclamation.
13
Our Commitment
VIQUA is committed to ensuring your experience with our products and organization
exceeds your expectations. We have manufactured your UV purification system to
the highest quality standards and value you as our customer. Should you need any
support, or have questions about your system, please contact our Technical Support team
at 1.800.265.7246 or [email protected] and we will be happy to assist you.
We sincerely hope you enjoy the benefits of clean, safe drinking water after the installation
of your Sterilight® purification system.
How to Make a Warranty Claim
NOTE: To maximise the disinfection performance and reliability of your Sterilight® product,
the system must be properly sized, installed and maintained. Guidance on the necessary
water quality parameters and maintenance requirements can be found in your Owner’s
Manual.
In the event that repair or replacement of parts covered by this warranty are required, the
process will be handled by your dealer. If you are unsure whether an equipment problem
or failure is covered by warranty, contact our Technical Support team at 1.800.265.7246
or e-mail tec[email protected]. Our fully trained technicians will help you
troubleshoot the problem and identify a solution. Please have available the model number
(system type), the date of purchase, the name of the dealer from whom you purchased
your Sterilight® product (“the source dealer”), as well as a description of the problem you
are experiencing.
To establish proof of purchase when making a warranty claim, you will either need your
original invoice, or have previously completed and returned your product registration card
via mail or online.
Specific Warranty Coverage
Warranty coverage is specific to the Sterilight® Copper, Silver, Cobalt and Platinum range
of products. Warranty coverage is subject to the conditions and limitations outlined under
the heading “General Conditions and Limitations” below.
Seven-Year Limited Warranty for Sterilight® UV Chamber
VIQUA warrants the UV chamber on the Sterilight® product to be free from defects in
material and workmanship for a period of seven (7) years from the date of purchase.
During this time, VIQUA will repair or replace, at its option, any defective Sterilight® UV
chamber. Please return the defective part to your dealer who will process your claim.
Two-Year Limited Warranty for Electrical and Hardware Components
VIQUA warrants the electrical (power supply) and hardware components to be free
from defects in material and workmanship for a period of two (2) years from the date of
purchase. During this time, VIQUA will repair or replace, at its option, any defective parts
covered by the warranty. Please return the defective part to your dealer who will process
your claim.
One-Year Limited Warranty for Lamps, Sleeves and UV Sensors
VIQUA warrants lamps, sleeves and UV sensors to be free from defects in material and
workmanship for a period of one (1) year from the date of purchase. During this time,
VIQUA will repair or replace, at its option, any defective parts covered by the warranty.
Your dealer will process your claim and advise whether the defective item needs to be
returned for failure analysis.
manufaCTurers warranTy:
14
IMPORTANT NOTE: Use only genuine Sterilight® replacement lamps and sleeves in
your system. Failure to do so may seriously compromise disinfection performance
and affect warranty coverage.
General Conditions and Limitations
None of the above warranties cover damage caused by improper use or maintenance,
accidents, acts of God or minor scratches or imperfections that do not materially impair
the operation of the product. The warranties also do not cover products that are not
installed as outlined in the applicable Owner’s Manual.
Parts repaired or replaced under these warranties will be covered under warranty up to the
end of the warranty period applicable to the original part.
The above warranties do not include the cost of shipping and handling of returned items
The limited warranties described above are the only warranties applicable to the
Sterilight® range of products. These limited warranties outline the exclusive remedy for all
claims based on a failure of or defect in any of these products, whether the claim is based
on contract, tort (including negligence), strict liability or otherwise. These warranties are in
lieu of all other warranties whether written, oral, implied or statutory. Without limitation,
no warranty of merchantability or of fitness for a particular purpose shall apply to any of
these products.
VIQUA does not assume any liability for personal injury or property damage caused by
the use or misuse of any of the above products. VIQUA shall not in any event be liable
for special, incidental, indirect or consequential damages. VIQUAs liability shall, in all
instances, be limited to repair or replacement of the defective product or part and this
liability will terminate upon expiration of the applicable warranty period.
14
Garantie limitée d’un an pour les lampes, les manchons et les capteurs UV
VIQUA garantit que ses lampes, ses manchons et ses capteurs UV sont exempts de toute
défectuosité de matériel et de fabrication pendant une période d’un (1) an après la date
d’achat.
Au cours de cette période, VIQUA réparera ou remplacera, comme bon lui semble, les
pièces
défectueuses couvertes par la garantie. Votre revendeur traitera votre réclamation et vous
avisera si vous devez retourner la pièce défectueuse pour une analyse de défaillance.
REMARQUE IMPORTANTE : N’utilisez que des lampes et des manchons de rechange
d’origine Sterilight® dans votre système. Tout manquement à cet égard peut grave-
ment compromettre la capacité de désinfection de votre système ainsi que la couver-
ture de la garantie
Conditions et restrictions générales
Les garanties précédentes ne couvrent pas les dommages causés par un usage ou un
entretien inapproprié, un accident ou une calamité naturelle ni les petites égratignures et
imperfections qui n’affectent pas de façon appréciable le fonctionnement du produit. Les
garanties ne protègent pas les produits qui ne sont pas installés conformément aux indica-
tions dans le manuel du propriétaire approprié.
Les pièces réparées ou remplacées en vertu de ces garanties sont couvertes jusqu’à la fin
de la période de garantie applicable de la pièce originale.
Les garanties précédentes ne comprennent pas le coût de l’expédition et de manutention
des pièces retournées.
Les garanties limitées précédentes sont les seules garanties applicables aux produits des
gammes Sterilight®. Ces garanties limitées énoncent votre recours exclusif pour toutes
les réclamations attribuables à une défaillance ou à une défectuosité d’un de ces produits,
peu importe que la réclamation soit basée sur un contrat, un tort (y compris la négligence),
une responsabilité absolue ou autre. Ces garanties remplacent toute autre garantie, qu’elle
soit écrite, verbale, tacite ou accordée par la loi. Sans restriction, aucune garantie de valeur
marchande ou d’adaptation à un usage particulier ne s’applique à ces produits.
VIQUA n’assume aucune responsabilité pour les blessures personnelles ou les dommages
matériels causés par l’utilisation ou l’usage abusif des produits ci-dessus. VIQUA décline
toute responsabilité pour les dommages spéciaux, accessoires, indirects ou consécutifs,
peu importe les circonstances. La responsabilité de VIQUA se limite, dans tous les cas, à
la réparation ou au remplacement de la pièce ou du produit défectueux et cette respon-
sabilité prend fin à la fin de la période de garantie applicable.
15
MODEL S1Q-DWS S2Q-DWS S5Q-DWS
Flow Rate
US Public
Health
16 mJ/cm2
12 lpm
(3.3 gpm)
(0.8 m3/Hr.)
15 lpm
(5 gpm)
(1.1 m3/Hr.)
42 lpm
(11 gpm)
(2.5 m3/Hr.)
VIQUA
Standard
30 mJ/cm2
7 lpm
(2 gpm)
(0.4 m3/Hr.)
11 lpm
(3 gpm)
(0.7 m3/Hr.)
23 lpm
(6 gpm)
(1.4 m3/Hr.)
NSF/EPA
40 mJ/cm2
5 lpm
(1.5 gpm)
(0.3 m3/Hr.)
7 lpm
(2 gpm)
(0.4 m3/Hr.)
17 lpm
(4.5 gpm)
(1.0 m3/Hr.)
Dimensions
Length 42cm (16.5”) 39cm (15.5”) 52cm (20.5”)
Width 35cm
(14”)
38cm
(15”)
71cm
(28”)
Height 15cm
(6”)
15cm
(6”)
15cm
(6”)
Shipping Weight 6.5kg
(14lbs.)
7.3kg
(16lbs.) 9.1kg (20lbs.)
Electrical
Voltage 100-240V./
50-60Hz1
100-240V./
50-60Hz1
100-240V./
50-60Hz1
Power
Consumption 19W 22W 30W
Lamp
Watts 14W 17W 25W
Maximum Operating
Pressure
8.62 bar
(125 psi)
8.62 bar
(125 psi)
8.62 bar
(125 psi)
Ambient
Temperature
2-40˚C
(36-104˚F)
2-40˚C
(36-104˚F)
2-40˚C
(36-104˚F)
Installation Kit Yes Yes N/A
Visual
“Power-On” Yes Yes Yes
Audible Lamp
Failure Yes Yes Yes
Sediment
Cartridge AWP110 AWP110 AWP110-2
Carbon Cartridge AWP117 AWP117 C-02
Chamber Material 304 S.S. 304 S.S. 304 S.S.
sPeCifiCaTions:
15
MODÈLE S1Q-DWS S2Q-DWS S5Q-DWS
Débit
16 mJ/cm2
Sante publique
É.U.
12 lpm
(3,3 gpm)
(0,8 m3/Hr)
15 lpm
(5 gpm)
(1,1 m3/Hr)
42 lpm
(11 gpm)
(2,5 m3/Hr)
30 mJ/cm2
Standard
VIQUA
7,5 lpm
(2 gpm)
(0,5 m3/Hr)
11 lpm
(3 gpm)
(0,7 m3/Hr)
23 lpm
(6 gpm)
(1,4 m3/Hr)
40 mJ/cm2
Standard
NSF/APE
5,5 lpm
(1,5 gpm)
(0,3 m3/Hr)
7 lpm
(2 gpm)
(0,4 m3/Hr)
17 lpm
(4,5 gpm)
(1,0 m3/Hr)
Dimensions
Longueur 42 cm
(16,5 po)
39 cm
(15,5 po)
52 cm
(20,5 po)
Largeur 35 cm
(14 po)
38 cm
(15 po)
71 cm
(28 po)
Hauter 15 cm
(6 po)
15 cm
(6 po)
15 cm
(6 po)
Poids à L’expédition 6,5kg
(14 lbs)
7,3kg
(16 lbs)
9,1kg
(20 lbs)
Alimentation
Électique
Volts 100-240V/
50-60Hz1
100-240V/
50-60Hz1
100-240V/
50-60Hz1
Consommation
Électrique 19W 22W 30W
Puissance
de la lampe 14W 17W 25W
Pression Maximum
D’utilisation
8,62 bar
(125lb/po2))
8,62 bar
(125lb/po2))
8,62 bar
(125lb/po2))
Température
Ambiante
2-40 ˚C
(36-104 ˚F)
2-40 ˚C
(36-104 ˚F)
2-40 ˚C
(36-104 ˚F)
Installation Kit Oui Oui N/A
Alarme visuelle
pour “alimenation Oui Oui Oui
Alarme défailance
lampe Oui Oui Oui
Sediment Cartridge AWP110 AWP110 AWP110-2
Carbon Catridge AWP117 AWP117 C-02
Matériau De La
Chambre UV
Acier Inoxydable
304
Acier Inoxydable
304
Acier Inoxydable
304
fiChe TeChnique :
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19

Sterilight S5Q-DWS Installation Instructions & Owner's Manual

Taper
Installation Instructions & Owner's Manual

dans d''autres langues