Oracle SAS-2 Upgrade Manual

Taper
Upgrade Manual

Ce manuel convient également à

SAS-1/SAS-2 Compatibility Upgrade Guide
For the Sun Blade 6000 Modular System
Part No.: E21704-01
March 2011, Revision A
Please
Recycle
Copyright © 2011 Oracle and/or its affiliates. All rights reserved.
This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by
intellectual property laws. Except as expressly permitted in your license agreement or allowed by law, you may not use, copy, reproduce, translate,
broadcast, modify, license, transmit, distribute, exhibit, perform, publish, or display any part, in any form, or by any means. Reverse engineering,
disassembly, or decompilation of this software, unless required by law for interoperability, is prohibited.
The information contained herein is subject to change without notice and is not warranted to be error-free. If you find any errors, please report them to us
in writing.
If this is software or related software documentation that is delivered to the U.S. Government or anyone licensing it on behalf of the U.S. Government, the
following notice is applicable:
U.S. GOVERNMENT RIGHTS Programs, software, databases, and related documentation and technical data delivered to U.S. Government customers are
"commercial computer software" or "commercial technical data" pursuant to the applicable Federal Acquisition Regulation and agency-specific
supplemental regulations. As such, the use, duplication, disclosure, modification, and adaptation shall be subject to the restrictions and license terms set
forth in the applicable Government contract, and, to the extent applicable by the terms of the Government contract, the additional rights set forth in FAR
52.227-19, Commercial Computer Software License (December 2007). Oracle America, Inc., 500 Oracle Parkway, Redwood City, CA 94065.
This software or hardware is developed for general use in a variety of information management applications. It is not developed or intended for use in any
inherently dangerous applications, including applications which may create a risk of personal injury. If you use this software or hardware in dangerous
applications, then you shall be responsible to take all appropriate fail-safe, backup, redundancy, and other measures to ensure its safe use. Oracle
Corporation and its affiliates disclaim any liability for any damages caused by use of this software or hardware in dangerous applications.
Oracle and Java are registered trademarks of Oracle and/or its affiliates. Other names may be trademarks of their respective owners.
AMD, Opteron, the AMD logo, and the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices. Intel and Intel Xeon are
trademarks or registered trademarks of Intel Corporation. All SPARC trademarks are used under license and are trademarks or registered trademarks of
SPARC International, Inc. UNIX is a registered trademark licensed through X/Open Company, Ltd.
This software or hardware and documentation may provide access to or information on content, products, and services from third parties. Oracle
Corporation and its affiliates are not responsible for and expressly disclaim all warranties of any kind with respect to third-party content, products, and
services. Oracle Corporation and its affiliates will not be responsible for any loss, costs, or damages incurred due to your access to or use of third-party
content, products, or services.
Copyright © 2011, Oracle et/ou ses affiliés. Tous droits réservés.
Ce logiciel et la documentation qui l’accompagne sont protégés par les lois sur la propriété intellectuelle. Ils sont concédés sous licence et soumis à des
restrictions d’utilisation et de divulgation. Sauf disposition de votre contrat de licence ou de la loi, vous ne pouvez pas copier, reproduire, traduire,
diffuser, modifier, breveter, transmettre, distribuer, exposer, exécuter, publier ou afficher le logiciel, même partiellement, sous quelque forme et par
quelque procédé que ce soit. Par ailleurs, il est interdit de procéder à toute ingénierie inverse du logiciel, de le désassembler ou de le décompiler, excepté à
des fins d’interopérabilité avec des logiciels tiers ou tel que prescrit par la loi.
Les informations fournies dans ce document sont susceptibles de modification sans préavis. Par ailleurs, Oracle Corporation ne garantit pas qu’elles
soient exemptes d’erreurs et vous invite, le cas échéant, à lui en faire part par écrit.
Si ce logiciel, ou la documentation qui l’accompagne, est concédé sous licence au Gouvernement des Etats-Unis, ou à toute entité qui délivre la licencede
ce logiciel ou l’utilise pour le compte du Gouvernement des Etats-Unis, la notice suivante s’applique :
U.S. GOVERNMENT RIGHTS. Programs, software, databases, and related documentation and technical data delivered to U.S. Government customers
are "commercial computer software" or "commercial technical data" pursuant to the applicable Federal Acquisition Regulation and agency-specific
supplemental regulations. As such, the use, duplication, disclosure, modification, and adaptation shall be subject to the restrictions and license terms set
forth in the applicable Government contract, and, to the extent applicable by the terms of the Government contract, the additional rights set forth in FAR
52.227-19, Commercial Computer Software License (December 2007). Oracle America, Inc., 500 Oracle Parkway, Redwood City, CA 94065.
Ce logiciel ou matériel a été développé pour un usage général dans le cadre d’applications de gestion des informations. Ce logiciel ou matériel n’est pas
conçu ni n’est destiné à être utilisé dans des applications à risque, notamment dans des applications pouvant causer des dommages corporels. Si vous
utilisez ce logiciel ou matériel dans le cadre d’applications dangereuses, il est de votre responsabilité de prendre toutes les mesures de secours, de
sauvegarde, de redondance et autres mesures nécessaires à son utilisation dans des conditions optimales de sécurité. Oracle Corporation et ses affiliés
déclinent toute responsabilité quant aux dommages causés par l’utilisation de ce logiciel ou matériel pour ce type d’applications.
Oracle et Java sont des marques déposées d’Oracle Corporation et/ou de ses affiliés.Tout autre nom mentionné peut correspondre à des marques
appartenant à d’autres propriétaires qu’Oracle.
AMD, Opteron, le logo AMD et le logo AMD Opteron sont des marques ou des marques déposées d’Advanced Micro Devices. Intel et Intel Xeon sont des
marques ou des marques déposées d’Intel Corporation. Toutes les marques SPARC sont utilisées sous licence et sont des marques ou des marques
déposées de SPARC International, Inc. UNIX est une marque déposée concédée sous licence par X/Open Company, Ltd.
Ce logiciel ou matériel et la documentation qui l’accompagne peuvent fournir des informations ou des liens donnant accès à des contenus, des produits et
des services émanant de tiers. Oracle Corporation et ses affiliés déclinent toute responsabilité ou garantie expresse quant aux contenus, produits ou
services émanant de tiers. En aucun cas, Oracle Corporation et ses affiliés ne sauraient être tenus pour responsables des pertes subies, des coûts
occasionnés ou des dommages causés par l’accès à des contenus, produits ou services tiers, ou à leur utilisation.
iii
Contents
Using This Documentation v
1. SAS-1/SAS-2 Compatibility Upgrade Instructions 1
Overview 1
System Requirements for the SAS-1/SAS-2 Compatibility Upgrade 2
List of SAS-1 Server Modules That Are Compatible With SAS-2 Upgrade 3
Upgrading Disk Module and SAS-NEM Expander Firmware 4
Obtain the Latest Disk Module and SAS-NEM Expander Firmware for SAS-
1/SAS-2 Coexistence 5
Obtain the Firmware Update Utility to Deploy the Required Expander
Firmware 6
Upgrade Disk Module and SAS-NEM Firmware Using the fwupdate
Utility 7
A. Using the lsiutil Software 15
Where to Obtain the lsiutil Software 15
Installing lsiutil 16
Using lsiutil From the Command Line 16
Using the Interactive lsiutil Menus 16
Why Save LSI Host Bus Adapter Persistent Mappings? 20
When to Save LSI Host Bus Adapter Persistent Mappings 20
Saving and Restoring a Persistence Map 21
iv Book Title without trademarks, or an abbreviated book title March 2011
Save a Snapshot of Your Host Bus Adapter Persistent Mappings 21
Restore a Snapshot of Your Host Bus Adapter Persistent Mappings 25
Index 29
v
Using This Documentation
This document describes how to upgrade SAS-1 Network Express Modules (NEMs)
and disk modules in Sun Blade 6000 Modular System from Oracle to allow SAS-
1/SAS-2 device coexistence.
Related Documentation
For the most up-to-date information about your server, refer to its documentation set
located at
(http://www.oracle.com/technetwork/documentation/index.html)
Documentation Comments
Submit comments about this document by clicking the Feedback[+] link at:
(http://www.oracle.com/technetwork/documentation/index.html)
Please include the title and part number of your document with your feedback:
SAS-1/SAS-2 Compatibility Upgrade Guide For the Sun Blade 6000 Modular System.
vi Book Title without trademarks, or an abbreviated book title March 2011
1
CHAPTER
1
SAS-1/SAS-2 Compatibility
Upgrade Instructions
This document provides information on compatibility requirements for a server
module with a SAS-2 RAID Expansion Module (REM) in a Sun Blade 6000 Modular
System chassis that has SAS-1 Network Express Modules (NEMs), or SAS-1 NEMs
and Sun Blade 6000 Disk Modules (which are SAS-1 devices).
You must perform the firmware upgrade procedure in this document before inserting
your server module with a SAS-2 REM into a SAS-1 system chassis.
Note Refer to your device’s documentation to determine its SAS level.
Alternatively, you can identify SAS-1 and SAS-2 devices by the maximum data
transfer speeds supported by the devices. SAS-1 devices support a maximum data
transfer speed of 3 Gb per second. SAS-2 devices support a maximum data transfer
speed of 6 Gb per second.
The following topics are covered:
“Overview” on page 1
“System Requirements for the SAS-1/SAS-2 Compatibility Upgrade” on page 2
“Upgrading Disk Module and SAS-NEM Expander Firmware” on page 4
Overview
A server module with a SAS-2 REM might hang when inserted into a Sun Blade 6000
Modular System chassis under the following conditions:
If the chassis contains SAS-1 NEMs, such as:
Sun Blade 6000 Multi-Fabric Network Express Module
2 Book Title without trademarks, or an abbreviated book title March 2011
Sun Blade 6000 Virtualized Multi-Fabric 10GbE Network Express Module
If the chassis contains Sun Blade 6000 Disk Modules (SAS-1 devices)
To ensure optimal system performance and avoid the potential for a system hang,
you need to upgrade the SAS expander firmware of all SAS-1 NEMs and Sun Blade
6000 Disk Modules in the chassis to the latest available firmware update that
supports SAS-1/SAS-2 coexistence.
The Sun Blade X6270 M2 is an example of a server module that ships with a SAS-2
REM. If you install a SAS-2 REM into a server module that previously did not have
one, you will need to perform this upgrade before installing the server module into
the chassis. Refer to your product documentation to determine whether your server
module includes a SAS-2 REM (for more on available SAS-2 REMs, refer to “System
Requirements for the SAS-1/SAS-2 Compatibility Upgrade” on page 2).
After performing the SAS-1/SAS-2 compatibility upgrade, the server module with
the SAS-2 REM will be supported in the SAS-1 chassis with the following conditions:
The SAS-2 server module will function properly in the chassis and be able to use
its own internal SAS-2 storage and its PCIe Express Modules (EMs).
The SAS-2 server module will be able to use the network component of SAS-1
NEMs.
The SAS-2 server module cannot use disks in a Sun Blade 6000 Disk Module (a
SAS-1 device). This is an unsupported configuration.
The SAS-2 server module must be installed in a chassis slot that does not have a
Sun Blade 6000 Disk Module in an adjacent slot.
System Requirements for the
SAS-1/SAS-2 Compatibility Upgrade
Currently available SAS-1 NEMs and disk modules that include SAS expanders that
require the SAS-1/SAS-2 compatibility upgrade are listed below.
Sun Blade 6000 Disk Module (B18-AA)
Sun Blade 6000 Multi-Fabric Network Express Module (X4212A)
Sun Blade 6000 10GbE Multi-Fabric Network Express Module (X4236A)
Sun Blade 6000 Virtualized Multi-Fabric 10GbE Network Express Module (X4238)
In addition, if your device contains an Integrated Lights Out Manager (ILOM)
service processor, it might also require an upgrade to match the new expander
firmware.
Chapter 1 SAS-1/SAS-2 Compatibility Upgrade Instructions 3
TABLE 1-1 lists the currently available server module SAS-2 REMs affected by this
issue, and the minimum required SAS-1/SAS-2 compatibility firmware for SAS-1
devices to fix the issue.
Proceed to “Upgrading Disk Module and SAS-NEM Expander Firmware” on page 4
for instructions on performing the upgrade.
List of SAS-1 Server Modules That Are
Compatible With SAS-2 Upgrade
TABLE 1-2 lists server modules equipped with either an LSI SAS-1 on-board chip or a
supported SAS-1 REM HBA that you can use to perform the SAS-1/SAS-2
compatibility upgrade. Since the upgrade to the affected SAS-1 devices (NEMs and
disk modules) must be done through the SAS-1 bus, the server module(s) at which
the upgrade will be performed must have one of the supported HBAs.
TABLE 1-1 Supported SAS-2 REMs and Required SAS-1 Device Firmware
If Your Server Module Has One of
These SAS-2 REMs:
Minimum Required SAS-1
Expander Firmware for Sun
Blade 6000 Disk Modules:
Minimum Required SAS-1
Expander Firmware for Sun
Blade 6000 Multi-Fabric
NEMs:
Minimum Required SAS-1
Expander and ILOM
Firmware for Sun Blade 6000
Virtualized Multi-Fabric
10GbE NEMs:
Sun Storage 6 Gb SAS REM
RAID HBA (SGX-SAS6-R-
REM-Z)
Sun Storage 6 Gb SAS REM
HBA (SGX-SAS6-REM-Z)
Expander version
5.04.03, available in Sun
Blade 6000 Disk Module
software release 2.1
Expander version
5.04.03, available in Sun
Blade 6000 Disk Module
software release 2.1
Expander version 5.04.03
and ILOM version
2.0.3.12, available in Sun
Blade 6000 Virtualized
Multi-Fabric 10GbE NEM
software release 2.2.
4 Book Title without trademarks, or an abbreviated book title March 2011
Note The REM HBAs must have a minimum firmware level of v1.25.00 (also
referred to as Phase 13); otherwise, the firmware upgrade will not work. For
instructions on how to check HBA versions, see “Checking Host Bus Adapter
Firmware Versions on x86 Server Blades” in the Sun Blade 6000 Disk Module
Administration Guide.
Upgrading Disk Module and SAS-NEM
Expander Firmware
Perform the SAS-1/SAS-2 compatibility upgrade on all SAS-1 NEMs and Sun Blade
6000 Disk Modules before attempting to install your SAS-2 server module into the
chassis. The upgrade can only be performed from server modules in the chassis and
only from server modules with a supported SAS-1 REM or on-board LSI controller
chip.
TABLE 1-2 Supported Server Blades With LSI SAS-1 On-board Chips and SAS-1 REM
Host Bus Adapters
Server
Supported On-board
SAS-1 Controller
Chip Supported SAS-1 RAID Expansion Module (REM)
T6300 LSI 1068E REMs are not supported in this server
T6320 None T6320 RAID 0/1 Expansion Module (LSI)
Sun Blade RAID 0/1 G2 Expansion Module (LSI)
T6340 None Sun Blade RAID 0/1 G2 Expansion Module (LSI)
X6220 LSI 1068E REMs are not supported in this server.
X6240 None Sun Blade RAID 0/1 G2 Expansion Module (LSI)
Sun Blade RAID 5 Expansion Module (Intel/Adaptec)
X6250 None Sun Blade RAID 5 Expansion Module (Intel/Adaptec)
X6270 None Sun Blade RAID 0/1 G2 Expansion Module (LSI)
Sun Blade RAID 5 Expansion Module (Intel/Adaptec)
X6440 None Sun Blade RAID 0/1 G2 Expansion Module (LSI)
Sun Blade RAID 5 Expansion Module (Intel/Adaptec)
X6450 None Sun Blade RAID 0/1 G2 Expansion Module (LSI)
Sun Blade RAID 5 Expansion Module (Intel/Adaptec)
Chapter 1 SAS-1/SAS-2 Compatibility Upgrade Instructions 5
A list of server modules with SAS-1 Host Bus Adapters (HBAs) capable of
performing the upgrade can be found in “List of SAS-1 Server Modules That Are
Compatible With SAS-2 Upgrade” on page 3.
Obtain the Latest Disk Module and SAS-NEM
Expander Firmware for SAS-1/SAS-2 Coexistence
To support SAS-1/SAS-2 coexistence, SAS expanders for both the Sun Blade 6000
Disk Modules and SAS-1 NEMs must be at firmware version 5.04.03, at a minimum.
You need to download the latest available firmware update for your platform.
For Sun Blade 6000 Disk Modules, download Sun Blade 6000 Disk Module
Software 2.1. This version also includes expander firmware for the Sun Blade
6000 Multi-Fabric Network Express Module.
For the Sun Blade 6000 Virtualized Multi-Fabric 10GbE Network Express Module,
download Sun Blade 6000 Virtualized Multi-Fabric 10GbE Network Express
Module Software 2.2. This version includes both expander firmware and ILOM
firmware.
For the Sun Blade 6000 10GbE Multi-Fabric Network Express Module, check My
Oracle Support (MOS) Patches and Updates for a supported release that contains
expander firmware version 5.04.03 or later firmware update.
To download the appropriate software release, go to My Oracle Support (MOS)
(http://support.oracle.com) and do the following:
Select Patches & Updates -> Product or Family (Advanced Search).
Search for the following updates:
Sun Blade 6000 Disk Module (minimum version 2.1)
Sun Blade 6000 10GbE VMF (minimum version 2.2)
Sun Blade 6000 10GbE Switched NEM (version containing 5.04.03)
6 Book Title without trademarks, or an abbreviated book title March 2011
TABLE 1-3 lists the download image names for each SAS-1 NEM and disk module that
requires a firmware upgrade.
Note You might need to set up an online account before downloading the
software release.
Obtain the Firmware Update Utility to Deploy the
Required Expander Firmware
To upgrade the disk module and SAS-NEM expander firmware to the required level
for SAS-1/SAS-2 coexistence, you can use the Firmware Update command-line tool
(fwupdate) included in Oracle Hardware Management Pack (minimum supported
version 2.0.1. Upgrade instructions in this document describe using this tool).
The fwupdate tool included with Hardware Management Pack 2.0.1 can be run
from supported Sun x86 or SPARC servers from Oracle. The tool is also supported
on Oracle Solaris, Linux, and Windows operating systems. Refer to the Hardware
Management Pack 2.0 documentation for details.
To obtain Hardware Management Pack 2.0.1, go to My Oracle Support (MOS)
(http://support.oracle.com) and do the following:
1. Select Patches & Updates -> Product or Family (Advanced Search).
2. Search for Oracle Hardware Management Pack (minimum version 2.0.1).
Note You might need to first setup an online account before downloading the
software release.
TABLE 1-3 SAS-1 NEM and Disk Module Download Image Names
SAS-1 NEM or Disk Module Download Image Names
Sun Blade 6000 Disk Module Software 2.1 (B18-AA) mfgImageCust03V.5.04.03.bin
sasxfwnv.5.04.03.fw
Sun Blade 6000 Multi-Fabric Network Express
Module (X4212A)
mfgImageCust03N.5.04.03.bin
sasxfwnv.5.04.03.fw
Sun Blade 6000 10GbE Multi-Fabric Network
Express Module (X4236A)
mfgImageCust03G.5.04.03.bin
sasxfwgv.5.04.03.fw
Sun Blade 6000 Virtualized Multi-Fabric 10GbE
Network Express Module Software 2.2 (X4238)
mfgImageCust03N.5.04.03.bin
sasxfwhv.5.04.03.fw
Chapter 1 SAS-1/SAS-2 Compatibility Upgrade Instructions 7
Upgrade Disk Module and SAS-NEM Firmware
Using the fwupdate Utility
The Hardware Management Pack 2.0.1 includes a firmware update command-line
tool that works across platforms (x86/64 and SPARC) and operating systems (Oracle
Solaris, Windows, Linux). You must use this tool to perform the SAS-1/SAS-2
coexistence firmware upgrade. It is recommended that you stop all SAS I/O traffic
before performing the SAS-NEM firmware upgrade.
Note Upgrading SAS-NEM and disk module firmware can disrupt SAS I/O traffic
throughout the chassis. Plan on performing the SAS-NEM firmware upgrade at a
time when you can temporarily stop host to disk module I/O. Performing the
upgrade while booted from the disk module is not supported.
Before You Begin:
Ensure complete backup of your data is available. Use lsiutil to make snapshot
backups of all LSI HBAs attached to Disk Module. For more information, see
Appendix a.
If your chassis has Sun Blade 6000 Disk Modules installed, download the
appropriate Sun Blade 6000 Disk Module software package from the Oracle
download site to each server module equipped with a SAS-1 REM that is slot-
paired with a Sun Blade 6000 Disk Module. See “Obtain the Latest Disk Module
and SAS-NEM Expander Firmware for SAS-1/SAS-2 Coexistence” on page 5.
Download the appropriate SAS-1 NEM software package to a server module. If
you have Sun Blade 6000 Disk Modules installed, download it to one server
module equipped with a SAS-1 REM that is slot-paired with a Sun Blade 6000
Disk Module. See “Obtain the Latest Disk Module and SAS-NEM Expander
Firmware for SAS-1/SAS-2 Coexistence” on page 5.
Download the Oracle Hardware Management Pack 2.0.1 version required (several
OS versions are available) to a server module. If you have Sun Blade 6000 Disk
Modules installed, download it to each server module equipped with a SAS-1
REM that is slot-paired with a Sun Blade 6000 Disk Module. Extract the archive
file and run the component installer to install the fwupdate tool. See “Obtain the
Firmware Update Utility to Deploy the Required Expander Firmware” on page 6.
Note The fwupdate tool and firmware image files must be copied to and run
from servers in the chassis. They cannot be run from a network share.
If available, start at a server module slot-paired with a Sun Blade 6000 Disk Module,
then do the following:
1. Open a terminal or command prompt at the host.
8 Book Title without trademarks, or an abbreviated book title March 2011
Note You must be logged in with root permission level to run fwupdate
commands on Unix-based platforms, or Administrator permission level for
Windows platforms. These instructions can be used on servers running Oracle
Solaris, Linux, or Windows.
2. Change directories to where the fwupdate tool is located.
Note It is not necessary to change directories if fwupdate is in your search path.
Chapter 1 SAS-1/SAS-2 Compatibility Upgrade Instructions 9
3. Identify the SAS expanders by entering the command:
fwupdate list all
All controllers, expanders, and connected devices are listed. Expanders for both
the SAS-NEMs and the slot-paired disk module will be identified. Make a note of
all the expander IDs.
Example output might look like this:
The following expander components must be upgraded:
Network Express Module (NEM) expanders:
The expander manufacturing image
The expander firmware
Disk module expanders (both Master and Slave):
The expander manufacturing image
The expander firmware
CONTROLLER c0
=============
Manufacturer Model Product Name F/W Version BIOS Version
--------------------------------------------------------------------------
LSI Logic 0x0058 LSIREM 01.26.92.00 06.24.01.00
EXPANDERS
===============
ID Chassis Manufacturer Model Expander Name FW Version
--------------------------------------------------------------------------
c0x0 0 SUN NEMHydra_C10 Master 5.2.14.0
c0x1 1 SUN NEMHydra_C10 Master 5.2.14.0
c0x2 2 SUN Blade Storage Master 5.2.14.0
c0x3 3 SUN Blade Storage Slave 5.2.14.0
DISKS
===============
ID Brand Model Chassis Slot Type Media Size(GB)Firmware Rev.
------------------------------------------------------------------------------
c0d0 SEAGATE ST914602SSUN146G - - sas HDD 146 0603
c0d1 SEAGATE ST914602SSUN146G - - sas HDD 146 0400
c0d2 HITACHI H101414SCSUN146G - - sas HDD 146 SA02
c0d3 SEAGATE ST973402SSUN72G - - sas HDD 73 0603
c0d4 SEAGATE ST914602SSUN146G - - sas HDD 146 0603
c0d5 SEAGATE ST914602SSUN146G - - sas HDD 146 0400
c0d6 HITACHI H101414SCSUN146G - - sas HDD 146 SA02
c0d7 SEAGATE ST973402SSUN72G - - sas HDD 73 0603
10 Book Title without trademarks, or an abbreviated book title March 2011
Note It can take up to 2 minutes to upgrade expander firmware on each disk
module.
Note Though not recommended, if you later attempt to downgrade your expander
firmware, it must be done in the reverse order listed above (disk module expanders
first, then NEM expanders).
4. Upgrade the expander firmware of the SAS-1 disk module or NEM as follows:
a. Rename the manufacturing image from
/path/mfgImageCust03x.5.04.03.bin to mfgImageCust03x.bin.
Where x is a variable that is determined by the name of the image file for the
specific NEM expander being upgraded. For manufacturing image file names
for SAS-1 NEMs, see
TABLE 1-3.
b. Upgrade the manufacturing image by entering:
fwupdate update expander-manufacturing-image -n c0x0 -f
/path/mfgImageCust03x.bin
Where c0x0 is the ID for the target NEM expander, and path is the directory
path to where the image file is located, and x is determined by the name of the
manufacturing image file for the specific SAS-1 NEM expander being
upgraded (see
TABLE 1-3).
Example output might look like:
If the upgrade is not successful, review the fwupdate error log file to isolate
the problem and retry the upgrade. The fwupdate.log file is located in
/var/log/fwupdate/fwupdate.log in Solaris and Linux, and
/temp/log/fwupdate/fwupdate.log in Windows.
Note The firmware upgrade is successful if you see the keywords “succeeded” or
“success.” Wait until the firmware of the target expander has been successfully
upgraded before attempting any additional commands. The new manufacturing
image is not active until after the system has been power cycled. Ignore any
messages after the firmware was successfully upgraded.
The following components will be upgraded:
c0x0 [y/n]? y
Upgrade of c0x0 from 5.2.14.0 to 5.4.3.0 succeeded.
Chapter 1 SAS-1/SAS-2 Compatibility Upgrade Instructions 11
c. Upgrade the expander firmware by entering:
fwupdate update expander-firmware -n c0x0 -f /path/sasxfwx
v.5.04.03.fw
Where c0x0 is the ID for the target NEM expander, path is the directory path to
where the image file is located, and x is determined by the name of the
expander firmware file. For the name of the expander firmware file for the
specific SAS-1 NEM being upgraded, see
TABLE 1-3.
Example output might look like this:
Note Wait until the firmware of the target expander has been successfully
upgraded before attempting any additional commands. If you see an “Upgrade
succeeded, but is not yet active” message, it can be safely ignored.
d. If the chassis has two SAS-1 NEMs, repeat the upgrade process described in
Step b and Step c for the second NEM.
The example used here would include upgrading expander c0x1.
5. Upgrade the expander firmware of the host-paired Sun Blade 6000 Disk Module
as follows:
a. Rename the manufacturing image from
/path/mfgImageCust03x.5.04.03.bin to mfgImageCust03x.bin.
Where x is a variable that is determined by the name of the manufacturing
image file for the specific disk module expander being upgraded (see
TABLE 1-3).
Note The version of manufacturing image may not be machine readable. And
after the expander firmware is updated, the new version of the manufacturing image
is not readable until after the system has been power cycled.
The following components will be upgraded:
c0x0 [y/n]? y
Upgrade of c0x0 from 5.2.14.0 to 5.4.3.0 succeeded.
12 Book Title without trademarks, or an abbreviated book title March 2011
b. Upgrade the manufacturing image by entering:
fwupdate update expander-manufacturing-image -n c0x0 -f
/path/mfgImageCust03x.bin
Where c0x0 is the ID for the target NEM expander, and path is the directory
path to where the image file is located, and x is determined by the name of the
manufacturing image file for the specific disk module expander being
upgraded (see
TABLE 1-3).
Example output might look like:
Note Wait until the firmware of the target expander has been successfully
upgraded before attempting any additional commands. If you see an “Upgrade
succeeded, but is not yet active” message, it can be safely ignored.
If the upgrade is not successful, review the fwupdate error log file to isolate
the problem and retry the upgrade. The fwupdate.log file is located in
/var/log/fwupdate/fwupdate.log in Solaris and Linux, and
/temp/log/fwupdate/fwupdate.log in Windows.
c. Upgrade the expander firmware by entering:
fwupdate update expander-firmware -n c0x2 -f /path/sasxfwx
v.5.04.03.fw
Where c0x2 is the ID for the target disk module expander, path is the directory
path to where the image file is located, and x is determined by the name of the
disk module expander firmware file. For the name of the disk module
expander firmware file, see
TABLE 1-3.
Example output might look like this:
The following components will be upgraded as shown:
ID Priority Action Status OldFirmwareVer. ProposedVer.
NewFirmwareVer. SysReboot
c0x0 1 CheckFW Success N/A Not Provided N/A
None
Do you wish to process all of the above component upgrades? [y/n]? y
Updating c0x0: Success
The following components will be upgraded as shown:
ID Priority Action Status OldFirmwareVer. ProposedVer.
NewFirmwareVer. SysReboot
c0x2 1 CheckFW Success 5.2.14.0 Not Provided N/A
None
Do you wish to process all of the above component upgrades? [y/n]? y
Updating c0x2: Success
Chapter 1 SAS-1/SAS-2 Compatibility Upgrade Instructions 13
Note Wait until the firmware of the target expander has been successfully
upgraded before attempting any additional commands. If you see an “Upgrade
succeeded, but is not yet active” message, it can be safely ignored.
If the upgrade is not successful, review the fwupdate error log file to isolate
the problem and retry the upgrade. The fwupdate.log file is located in
/var/log/fwupdate/fwupdate.log in Solaris and Linux, and
/log/fwupdate/fwupdate.log in Windows.
d. Repeat Step b and Step c for the second expander in the disk module.
The example used here would include upgrading expander c0x3.
Note Both Master and Slave expanders in the disk module must be upgraded.
6. Shut down the host OS and power cycle the chassis.
If you are shutting down from a CMM, see
(http://docs.sun.com/source/820-0051-
11/service_preparation.html#50409492_pgfId-1045755)
or use the following CLI:
-> stop -f /CH
-> start /CH
7. When done, check that all host viewable SAS expanders are at the supported
version for SAS-1/SAS-2 coexistence (5.04.03) by entering the command:
fwupdate list all
Example output might look like this:
CONTROLLER c0
=============
Manufacturer Model Product Name F/W Version BIOS Version
--------------------------------------------------------------------------
LSI Logic 0x0058 LSIREM 01.26.92.00 06.24.01.00
EXPANDERS
===============
ID Chassis Manufacturer Model Expander Name FW Version
--------------------------------------------------------------------------
c0x0 0 SUN NEMHydra_C10 Master 5.4.3.0
c0x1 1 SUN NEMHydra_C10 Master 5.4.3.0
c0x2 2 SUN Blade Storage Master 5.4.3.0
c0x3 3 SUN Blade Storage Slave 5.4.3.0
DISKS
14 Book Title without trademarks, or an abbreviated book title March 2011
8. Proceed to the next SAS-1 server module slot-paired with a Sun Blade 6000
Disk Module and repeat Step 3 to obtain the expander IDs.
9. Repeat Step 5 through Step 8 until all SAS-1 disk modules in the chassis have
had their expanders upgraded.
10. If your SAS-1 NEMs have an ILOM service processor, you might also need to
upgrade its ILOM firmware to achieve a supported firmware level that is
matched to the new expander firmware.
For instructions on upgrading the ILOM service processor firmware for a SAS-1
NEM, refer to the NEM user’s guide. For more information on SAS-1 NEMs, see
“System Requirements for the SAS-1/SAS-2 Compatibility Upgrade” on page 2.
11. After you have upgraded all of your SAS-1 NEMs and disk modules, you can
safely insert your SAS-2 server module into the chassis.
The SAS-2 server module will be supported in the SAS-1 chassis with the
following conditions:
The SAS-2 server module will function properly in the chassis and be able to
use its own internal SAS-2 storage and its PCIe Express Modules (EMs).
The SAS-2 server module will be able to use the network component of SAS-1
NEMs.
The SAS-2 server module cannot use disks in a Sun Blade 6000 Disk Module (a
SAS-1 device). This is an unsupported configuration.
The SAS-2 server module must be installed in a chassis slot that does not have
a Sun Blade 6000 Disk Module in an adjacent slot.
Refer to the documentation that comes with your SAS-2 server module for
additional installation and configuration instructions.
===============
ID Brand Model Chassis Slot Type Media Size(GB)Firmware Rev.
------------------------------------------------------------------------------
c0d0 SEAGATE ST914602SSUN146G - - sas HDD 146 0603
c0d1 SEAGATE ST914602SSUN146G - - sas HDD 146 0400
c0d2 HITACHI H101414SCSUN146G - - sas HDD 146 SA02
c0d3 SEAGATE ST973402SSUN72G - - sas HDD 73 0603
c0d4 SEAGATE ST914602SSUN146G - - sas HDD 146 0603
c0d5 SEAGATE ST914602SSUN146G - - sas HDD 146 0400
c0d6 HITACHI H101414SCSUN146G - - sas HDD 146 SA02
c0d7 SEAGATE ST973402SSUN72G - - sas HDD 73 0603
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Oracle SAS-2 Upgrade Manual

Taper
Upgrade Manual
Ce manuel convient également à

dans d''autres langues