Best WCP3I30SB Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation

Ce manuel convient également à

WCP3I SERIES
HB0311
INSTALLATION INSTRUCTIONS
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 12 AND 13.
READ AND SAVE THESE INSTRUCTIONS
BEST; Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711
BEST; Drummondville, QC, Canada www.BestRangeHoods.ca 866-737-7770
23863 rev. 03
! !
2
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA) and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented outdoors.
7. Do not use this unit with any solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. When applicable, local regulations comprise more
restrictive installation and/or certification requirements,
the aforementioned requirements prevail on those of this
document and the installer agrees to conform to these at his
own expense.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn power hood ON when cooking at high heat or
when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Your hood motor has a thermal overload which will automatically
shut off the motor if it overheats. The motor will restart when it
cools down. If the motor continues to shut off and restart, have
the hood serviced.
5. The minimum hood distance above cooktop must not be
less than 24” (30” over a gas range). A maximum of 30”
above cooktop is recommended for best capture of cooking
impurities.
6. Two installers are recommended because of the large size and
weight of this unit.
7. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside — Do not exhaust air into spaces within walls
or ceiling or into attics, crawl space or garage.
8. Because of the high exhausting capacity of this hood, you
should make sure enough air is entering the house. Open a
window close to or in the kitchen.
9. To reduce the risk of fire and electrical shock, the Best WCP3I
Series models should only be installed with their own built-in
blowers.
10. When used in recirculation mode, to reduce the risk of fire and
shock, use only conversion kit model HRKBSS.
11. Please read specification label on product for further
information and requirements.
WARNING
!
CAUTION
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels —
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to
operate it.
B. The fire is small and contained in the area where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
WARNING
!
3
1. PREPARE THE INSTALLATION
NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer.
Make sure that the following items are included:
- Hood
- Accessories • Decorative flue assembly (lower and upper flues)
• Hood mounting bracket
• Upper flue mounting bracket
• 2 hybrid filters
• 6” round adapter/damper (for vertical discharge), in a bag
• 3¼” x 10” adapter/damper (for horizontal or vertical discharge)
• Bag of parts including: 5 no. 8 x 1½” countersunk screws, 8 no. 8 x 3/4” screws, 6 no. 8 x 3/8” screws,
6 drywall anchors, 3 washers, 2 no. 8 x 1/2”, 2 neoprene pieces. If need be,
discard extra hardware.
Parts sold separately:
- Duct, elbows, wall or roof caps.
- Optional flue extension for 10-ft. ceilings model AEWCP3SB.
- Non-duct kit model HRKBSS, mandatory for non-ducted installation.
NOTE: The maximum ceiling height must not exceed 9 ft. when using a non-duct kit.
WARNING
!
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
2. SELECT INSTALLATION TYPE
NOTE: During the installation, protect countertop and/or cooktop.
2.1 NON-DUCTED INSTALLATION
The non-duct kit model HRKBSS is required for a non-ducted installation.
2.2 DUCTED INSTALLATION
Plan where and how the ductwork will be installed.
Install proper-sized ductwork, elbows and roof or wall cap depending on the type
of installation. For vertical discharge, use 6” round or 3¼” x 10” ductwork and for
horizontal discharge use 3¼” x 10” ductwork only. Use metal foil duct tape to seal duct
joints.
2.3 ALL INSTALLATIONS
The minimum hood distance above cooktop is 24” (30” over a gas range). A
maximum of 30” above cooktop is recommended for best capture of cooking
impurities.
Distances over 30” are at the installer and users discretion providing that ceiling
height and decorative flue length allow it.
HH0246A
3¼” X 10DUCT
OR 6 ” ROUND DUCT
ROOF CAP
3¼” X 10DUCT
WALL
C
AP
HOOD
DECORATIVE
FLUE
REFER TO CHART
FOR
DISTANCE ABOVE
COOKING SURFACE
CEILING HEIGHT
MINIMUM HOOD DISTANCE ABOVE
ELECTRIC RANGE COOKTOP
MINIMUM HOOD DISTANCE
ABOVE GAS RANGE COOKTOP
8 FT. 24 IN. 30 IN.
9
FT. 28½ IN. 30 IN.
10 FT.* 28½ IN. 30 IN.
* 10-ft. ceilings require flue extension model AEWCP3SB (sold separately).
Before installation, remove and discard the shipping bracket (in grey) and its retaining
screws. See illustration on the right.
HD0937
SCREW LOCATIONS
4
2. SELECT INSTALLATION TYPE (CONT'D)
Refer to illustrations below to locate duct opening according to discharge type chosen (grey parts to be installed later).
3. REMOVE HYBRID GREASE FILTERS
Rest the range hood on a table. Remove tapes on filters. Remove filters from range hood by
pushing them down and tilt, then set aside the filters.
Remove both styrofoam pieces and tape from under the blower and discard.
3”
2
7
/8
C
L
9¾”
HK0258A
14
15
/16
17
15
/16
30”
WIDTH HOOD
36” WIDTH HOOD
3¼”
15/16
VERTICAL DISCHARGE
12
7
/8
14
15
/16
C
L
9¾”
HK0273A
6
7
/16
17
15
/16
30”
WIDTH HOOD
36” WIDTH HOOD
3¼”
HORIZONTAL DISCHARGE
C
L
HK0261A
14
15
/16
17
15
/16
30”
WIDTH HOOD
36” WIDTH HOOD
6” DIA.
VERTICAL DISCHARGE OR NON-DUCTED INSTALLATION
HD1099
2
1
5
5. BLOWER REMOVAL (HORIZONTAL DISCHARGE ONLY)
These range hoods are factory shipped with the blower mounted for a vertical discharge configuration. For a horizontal discharge
configuration, disassemble the blower from the inner top of the hood (see procedure below). It will be assembled to the inner back of the
hood once the hood is mounted on the wall.
FOR HORIZONTAL DISCHARGE:
From outside the unit, remove the knockout from back of hood (see illustration beside).
HR0123
4. CHOOSE THE OPENING
2) Using a 5/16” socket, or a Robertson or a Phillips no. 2 screwdriver,
remove the 4 blower mounting screws (2 on each side) from the inner
top of the hood. Set the blower and screws aside.
1) Unplug the blower.
HD0386
RIGHT SIDE MOUNTING
SCREW LOCATIONS
HD0385
LEFT SIDE MOUNTING
SCREW LOCATIONS
HE0234
FOR VERTICAL DISCHARGE OR NON-DUCTED INSTALLATION:
Remove the knockout in order to clear vertical discharge opening (see illustration beside).
HR0122
6
7. WIRING INSTALLATION
WARNING
!
Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions
are not completely understood, or if there is any doubt as to whether the appliance is properly grounded. Do not
use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the
appliance, in accordance with all applicable codes and standards. Turn off electrical power at service entrance
before wiring.
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an
escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must
be plugged into an outlet that is properly installed and grounded.
Position the outlet within the space covered by the decorative flue. Place the outlet at a
maximum distance of 24” (from where the cord exits from the hood). The center of the outlet
must be positioned at 3½”
from the center of the future hood location (as illustrated beside).
Make sure this does not interfere with a mounting bracket fastening area or with the decorative
flue (where the flue touches the wall).
C
L
C
L
HE0233A
Secure the adapter/damper to the back of the hood using 2 no. 8 x 3/8” screws
(included). Seal the adapter/damper to the hood using metal foil duct tape.
NOTE: The wall ducting must be properly prepared to receive the adapter. Before
performing the installation, make sure the adapter fits easily in the duct.
HJ0129
6. INSTALL ADAPTER/DAMPER (6” ROUND OR 3¼” X 10”)
Mount the 6” round adapter/damper (included in bag) using 4 no. 8 x 3/8” screws (included) or the 3¼” x 10” adapter/damper to the hood
using 2 no. 8 x 3/8” screws (included). Seal the adapter/damper to the hood using metal foil duct tape.
HJ0139
HJ0140
VERTICAL DISCHARGE 3¼” X 10
H
ORIZONTAL DISCHARGE 3¼” X 10ONLY
VERTICAL DISCHARGE 6” ROUND AND
NON-DUCTED INSTALLATION ONLY
7
8. INSTALL HOOD MOUNTING BRACKET
Construct wood wall framing that is even with the surface of wall studs.
Wood wall framing must be at least 1/2” thick and 3” high. Fasten wood wall
framing to wall studs for a solid installation.
Make sure that the height of the framing will allow the mounting bracket
to be secured to the framing within the dimensions shown (see illustration
beside).
After wall surface is finished, carefully center and level the hood
mounting bracket over installation location. Secure it to wall framing using
3 no. 8 x 1½” screws.
Using a level, draw a vertical line up to the ceiling starting from the
mounting bracket center.
9. INSTALL UPPER FLUE MOUNTING BRACKET (DUCTED INSTALLATION ONLY)
10. INSTALL THE HOOD
WARNING
!
When cutting or drilling into wall, do not damage electrical
wiring and other hidden utilities.
Center the upper flue mounting bracket with the center line previously
drawn in step 8 and place it flush with the ceiling.
Use the upper flue mounting bracket as a template to mark the position of
its screws.
Drill the 3 screw holes using a 3/16” drill bit.
Insert the included drywall anchors into the drilled holes (1 per hole).
Secure the upper flue bracket to the wall using 3 no. 8 x 3/4” screws.
Ensure that the bracket is tight against the wall.
CAUTION
DO NOT REMOVE the protective plastic film covering the decorative flue (upper & lower) yet.
1. Align the hood and center it above the hood mounting bracket. Gently lower the
hood until it securely engages the bracket.
2. Level the hood.
3. With the hood hanging in place, mark both hole locations on wall (2 embossed
holes on back of hood; see illustration at right).
4. Remove the hood.
5. Drill through both marked holes on wall using a 3/16” drill bit. Insert the included
drywall anchors into the drilled holes (one for each hole).
6. Hang the hood to the wall bracket.
7. Secure the hood to the wall using 2 no. 8 x 3/4” screws and 2 washers.
36
7
/8” = BOTTOM OF HOOD 24” ABOVE COOKTOP
42
7
/8” = BOTTOM OF HOOD 30” ABOVE COOKTOP
SCREW LOCATIONS
HD0377
C
L
CEILING
MOUNTING BRACKET
FLUSH WITH CEILING
WARNING
!
BE CAREFUL when installing the decorative flue and hood, they may have sharp edges.
HOLE LOCATIONS
Ø 3/16” TYP.
HD0810A
SIDE VIEW
HD0813A
WALL STUDS
FRAMING BEHIND DRYWALL
NOTE: ILLUSTRATION ABOVE REPRESENTS HORIZONTAL
EXHAUST CONFIGURATION, BUT IT ALSO APPLIES TO
ALL CONFIGURATIONS.
8
11. REINSTALL BLOWER (HORIZONTAL DISCHARGE ONLY)
1) Position the blower on the inner back of the hood, as shown on the right.
2) Using a 5/16” socket, or a Robertson or a Phillips no. 2 screwdriver and the 4 screws
previously removed, secure the blower to the hood.
NOTE: In order to ease installation, before mounting the blower, prepare the screw holes
by screwing all 4 screws without the blower, then remove and mount the blower.
3) Plug the blower connector back in and plug hood power cord into the outlet.
HD0829
RIGHT SIDE
MOUNTING
SCREW
LOCATIONS
12. PLENUM INSTALLATION (NON-DUCTED INSTALLATION ONLY)
HD1025
Using 4 no. 8 x 3/8” provided screws, assemble the 6” round adapter to the lower plenum plate.
HD1024
A
A
A
Remove the shipping tape retaining the lower and upper plenum plates with the 6” round adapter
together. Carefully align the upper plenum plate central notch with the line traced in step 8 (see
inset at right) and place it flush to the ceiling. Use the plate as a template to mark the position (A)
of its screws.
NOTE: To ease installation, there are many screw configurations: 6 in ceiling and 2 in wall, on each
side. Only 4 screws are needed to hold the top plenum plate.
Insert the included drywall anchors in the marked holes, then secure the upper plate using
4 no. 8 x 3/4” screws and washers (included with non-duct kit). Make sure the plate is tight against
the wall and ceiling.
HA0135
Assemble the lower plenum plate and 6” round adapter assembly to the upper plate by inserting
both tabs of the top plenum plate to their corresponding slots in lower plenum plate. Secure the
plenum assemby using 2 no. 8-18 x 3/8” screws (included).
9
HJ0142
HJ0141
13. DUCT CONNECTION (VERTICAL DISCHARGE AND NON-DUCTED INSTALLATION ONLY)
VERTICAL DISCHARGE:
Plug hood power cord into the outlet. Slide a 6” round or a 3¼” x 10” metal duct over the adapter/damper on the hood. Use metal foil duct
tape to seal the joint.
NON-DUCTED INSTALLATION:
Plug hood power cord into the outlet.
Slide a 6” round flexible metal duct (included) over the adapter/damper on the hood.
Use metal foil duct tape to seal the joint.
HJ0153
Stretch the flexible metal duct up to the plenum, over the adapter. Use metal foil duct tape
to seal the joint.
HJ0155
10
14. PREPARE DECORATIVE FLUE
HO0271
LOWER FLUE
REAR NOTCH
DUCTED INSTALLATION:
Remove protective plastic film covering the lower flue only.
Peel off both corners at the top of the upper flue (note that upper part has one hole on left and right
sides; see image on the right).
Position the lower flue rear notches down.
Gently slide upper flue inside lower flue.
Both lower and upper flues are included with the hood, but for a 10-foot ceiling, discard the provided
upper flue and use the optional flue extension model AEWCP3SB (sold separately).
HA0078
LOUVERS
NON-DUCTED INSTALLATION:
Remove protective plastic film covering the lower flue only.
NOTE: Do not use the upper decorative flue included with the hood.
Peel off the plastic film covering both top corners of the upper decorative flue (included with
the non-duct kit).
Position the lower flue rear notches down (the ones with the 45° angle).
Gently slide upper flue inside lower flue, louvers end up.
11
15. INSTALL DECORATIVE FLUE
ALL INSTALLATIONS:
Carefully slide in place decorative flue base (notches end first) in the groove
(shaded part in inset at right) behind the exterior wall of the top of the hood.
DUCTED INSTALLATIONS:
Slide up the upper flue until it is aligned with its mounting bracket. The bracket must be
inside the flue. Secure the upper flue to its bracket using 2 no. 8 x 3/8” screws (included).
See illustration beside.
NOTE: Duct not shown in illustration to ease understanding.
16. REINSTALL HYBRID FILTERS
HO0140
UPPER FLUE MOUNTING BRACKET
FRONT VIEW
UPPER
FLUE
Rest rear filters edge on filter springs in the range hood. Using finger cup, tilt up the filters into position.
Make sure both tabs (A) are securely engaged in range hood front edge slots after installation.
HO0272
HD1100
A
NON-DUCTED INSTALLATION:
Slide the upper flue up to the ceiling. The plenum must be inside the flue. Secure the upper
flue to the plenum sides using 2 no. 8 x 3/8” screws (included) per side for stainless steel
model or 2 no. 8 x 1/2” black screws (included) per side for black stainless model.
NOTE: Ceiling not shown in illustration to ease understanding.
HA0136
ALL INSTALLATIONS:
Remove protective plastic film covering the upper flue.
12
17. LIGHTING
!
WARNING
Do not touch lamps during or soon after operation. Burns may occur. Cannot be replaced by any other type of light
bulb or LED module.
The lighting of WCP3I Series range hood is produced by two LED modules (included).
18. CARE
WARNING
!
Before servicing or cleaning the unit, switch power off at service panel and lock service panel to prevent power
from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
Hood cleaning
Avoid when choosing a detergent:
- Any cleaners that contain bleach will attack stainless steel.
- Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should never be
used close to a range.
Do:
Regularly wash with clean cloth or rag soaked with warm water
and mild phosphate-free soap or liquid dish detergent.
Always clean in the direction of original polish lines.
Always rinse well with clear water (2 or 3 times) after cleaning.
Wipe dry completely.
You may also use a specialized household stainless steel
cleaner
Don’t:
Use any steel or stainless steel wool or any other scrapers to
remove stubborn dirt.
Use any harsh or abrasive cleansers.
Allow dirt to accumulate.
Let plaster dust or any other construction residues reach the
hood. During construction/renovation, cover the hood to make
sure no dust sticks to stainless steel surface.
Grease Filters
The hybrid filters should be cleaned frequently. Use a warm dishwashing detergent solution. Grease filters are dishwasher safe.
Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filters may occur if using phosphate
detergents, or as a result of local water conditions - but this will not affect filter performance. This discoloration is not covered by the
warranty.
13
19. OPERATION
BLOWER BUTTON
When blower is OFF, press this button to turn ON the blower at the last saved speed. If there was no speed saved, the blower will be set
on LOW speed.
NOTE: When LOW speed is activated from OFF, the blower starts on MEDIUM speed for a very short lapse of time, and then resume to
LOW speed.
To change the blower speed, press on this button again until the desired speed is reached (from LOW to MEDIUM to HIGH speed to OFF).
Each time a blower speed is activated, a beep is heard and LED indicators light up to show the corresponding speed chosen (lower LED
for LOW speed, lower and center LEDs for MEDIUM speed and all LEDs for HIGH speed).
When blower is on (no matter the speed level), press and hold this button until the beep sound ends; this will turn off the blower and save
this blower speed to memory.
LIGHT BUTTON
When lights are OFF, press once on this button to turn ON the lights at the last saved setting. If there was no light setting saved, the lights
will be set on LOW intensity. Press another time to set the lights on HIGH intensity. Pressing another time after the HIGH setting will turn
OFF the lights. Each time the lights are turned ON, a beep is heard and LED indicators light up to show the corresponding intensity chosen
(lower LED for LOW and both LEDs for HIGH).
When lights are on (no matter the lighting level), press and hold this button until the beep sound ends; this will turn off the lights and save
the chosen light intensity.
FILTER CLEANING REMINDER
When it is time to clean the hood and filters, the 3 blower button LED indicators will flash slowly for 30 seconds after turning the blower OFF.
This will happen every time the blower is turned OFF until the filter cleaning reminder has been reset. Once the cleaning is done, reset
the filter cleaning reminder indicators by pressing on the blower button for 3 seconds while the 3 blower button LED indicators flash slowly.
Always turn your hood on before you begin cooking to establish an air flow in the kitchen.
Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and fresher.
Operate the hood as follows:
14
20. WIRING DIAGRAM
LINE
NEUTRAL
GROUND
120 V AC
CONTROL BOARD
J2
POWER
MOTOR
J6
OVERRIDE
5
4
32
1
6
J4
LED
J1
TRANSFORMER
RED
LED
LED
BLK
5
4
3
2
1
5
4
3
2
1
7
6
2
3
4
1
J10
INTERFACE
1
2
3
4
5
6
7
8
USER INTERFACE
MOUNTED TO J10
ON BACK OF
CONTROL BOARD
RED
FAN MOTOR
BRN
GRY
BLU
WHT
WHT
2
6
5
1
3
4
WHT
BLK
RED (LOW)
ORG (MEDIUM
)
BLK (HIGH)
BLK
WHT
WHT
BLU
BLU
RED
RED
BLK
BLK BLACK
BLU BLUE
BRN BROWN
GRY GREY
ORG ORANGE
RED RED
WHT WHITE
COLOR CODE
HE0236A
BLK
ORG
15
REPLACEMENT PARTS AND REPAIRS
In order to ensure your unit remains in good working condition, you must
use Broan-NuTone genuine replacement parts only. Broan-NuTone genuine
replacement parts are specially designed for each unit and are manufactured to
comply with all the applicable certification standards and maintain a high standard
of safety. Any third party replacement part used may cause serious damage and
drastically reduce the performance level of your unit, which will result in premature
failing. Broan-NuTone recommends to contact a certified service depot for all
replacement parts and repairs.
21. SERVICE PARTS
ITEM
NO.
PART NO.DESCRIPTION
QTY. (HOOD WIDTH)
30” 36”
1 SV63673 U
PPER FLUE MOUNTING BRACKET 11
2 SV63663 UPPER DECORATIVE FLUE, STAINLESS 11
3 SV63662 LOWER DECORATIVE FLUE, STAINLESS 11
4 S97020534 3¼” X 10ADAPTER/DAMPER 11
5 SV08487 6” ROUND ADAPTER/DAMPER 11
6 S97020444 LED MODULE (1) 2 2
7 S97020445 TRANSFORMER 11
8 SV08582
INTERNAL BLOWER
(INCLUDING CAPACITOR)
11
9 SV62053
H
YBRID FILTER
15.875” X 14X 0.5” (1)
22
10 S97020431
CAPACITIVE CONTROL
2 BUTTONS (STAINLESS)
11
11 SV09014 HOOD MOUNTING BRACKET 11
* SV05869 BEST LOGO 11
* SV23863 INSTALLATION GUIDE 11
* SV09027
P
ARTS BAG:
5 NO. 8 X 1½” COUNTERSUNK SCREWS,
8 NO. 8 X 3/4” SCREWS,
6 NO. 8 X 3/8” SCREWS,
6 DRYWALL ANCHORS, 3 WASHERS,
2 NO. 8 X 1/2” SCREWS
2 NEOPRENE PIECES
11
* N
OT SHOWN
HL0446
B
C
D
L
I
G
H
K
J
E
F
KEY
NO.
PART NO.DESCRIPTION QTY.
12 SV63628 NON-DUCT KIT UPPER DECORATIVE FLUE CHIMNEY 1
13 SV22756 6” ROUND METAL FLEXIBLE DUCT 1
14 SV63626 U
PPER PLENUM PLATE 1
15 SV63627 LOWER PLENUM PLATE 1
16 SV08487WD 6” ROUND ADAPTER 1
17 SV22759 CHARCOAL FILTER (PAIR)1
18 SV22757 CHARCOAL FILTER CLIP (SET OF 4) 1
* SV05803
PARTS BAG:
10 NO. 8-18 X 3/8” SCREWS,
4 NO. 8 X 1/2” BLACK SCREWS,
9 NO. 8-18 X 3/4” SCREWS, 4 WASHERS,
9 DRYWALL ANCHORS, 6 NO. 6 X 1/2” SCREWS.
1
* NOT SHOWN.
NON-DUCT KIT MODEL HRKBSS
HL0385
M
N
O
Q
P
S
R
16
22. WARRANTY
FIVE-YEAR LIMITED WARRANTY FOR BEST
®
PRODUCTS
Warranty Period and Exclusions: Broan-NuTone, LLC (the “Company”) warrants to the consumer purchaser of its product (“you”) that the product (the
“Product”) will be free from material defects in the materials or its workmanship for a period of five (5) years from the date of original purchase (or such
longer period as may be required by applicable law) or a period of two (2) years from the date of service for any labor provided on the Product.
The limited warranty period for any replacement parts provided by the Company and for any Products repaired or replaced under this limited warranty shall
be the remainder of the original warranty period (or such longer period as may be required by applicable law).
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES AND BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS
AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service, (b) normal wear and tear, (c) any Products or
parts which have been subject to misuse, abuse, abnormal usage, negligence, accident, improper or insufficient maintenance, storage or repair (other than
repair by the Company), (d) damage caused by faulty installation, or installation or use contrary to recommendations or instructions, (f) damage caused by
exposure to salt air, (g) damage in transit, (h) natural wear of finish, (i) Products in commercial or nonresidential use, (j) damage caused by fire, flood or
other act of God, or (k) Products with altered, defaced or removed serial numbers. This warranty covers only Products sold to consumers in North America.
This warranty supersedes all prior warranties and, subject to applicable law, is not transferable from the original consumer purchaser.
No Other Warranties: This Limited Warranty contains the Company’s sole obligation and your sole remedy for defective Products. The foregoing warranties
are exclusive and in lieu of any other warranties and conditions, express or implied. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THE
COMPANY DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS WARRANTIES AND CONDITIONS, AND DISCLAIMS AND EXCLUDES ALL WARRANTIES
AND CONDITIONS IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
To the extent that applicable law prohibits the exclusion of implied warranties or conditions, the duration of any applicable implied warranty or condition
is limited to the period specified for the express warranty above. Some jurisdictions (which may include the Province of Quebec or specific US states) do
not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Any oral or written description of the Product is
for the sole purpose of identifying it and shall not be construed as an express warranty.
Whenever possible, each provision of this Limited Warranty shall be interpreted in such manner as to be effective and valid under applicable law, but if any
provision is held to be prohibited or invalid, such provision shall be ineffective only to the extent of such prohibition or invalidity, without invalidating the
remainder of such provision or the other remaining provisions of the Limited Warranty.
Remedy: During the applicable limited warranty period, the Company will, at its option, provide replacement parts for, or repair or replace, without charge,
any Product or part thereof, to the extent the Company finds it to be covered by and in breach of this limited warranty under normal use and service. The
Company will ship the repaired or replaced Product or replacement parts to you at no charge. You are responsible for all costs for removal, reinstallation
and shipping, insurance or other freight charges incurred in the shipment of the Product or part to the Company. If you must send the Product or part
to the Company, as instructed by the Company, you must properly pack the Product or part—the Company is not responsible for damage in transit. The
Company reserves the right to utilize reconditioned, refurbished, repaired or remanufactured Products or parts in the warranty repair or replacement
process. Such Products and parts will be comparable in function and performance to an original Product or part and warranted for the remainder of the
original warranty period (or such longer period as may be required by applicable law).
Company reserves the right, in its sole discretion, to refund the money actually paid by you for the Product. If the Product or component is no longer
available, replacement may be made with a similar product of equal or greater value, at Company’s sole discretion. This is your sole and exclusive remedy
for breach of this limited warranty.
Exclusion of Damages: THE COMPANY’S OBLIGATION TO PROVIDE REPLACEMENT PARTS, OR REPAIR OR REPLACE, AT THE COMPANY’S OPTION,
SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY AND THE COMPANY’S SOLE AND EXCLUSIVE OBLIGATION. THE
COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL, INDIRECT, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
THE PRODUCT, ITS USE OR PERFORMANCE.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply
to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from jurisdiction to jurisdiction. The disclaimers,
exclusions, and limitations of liability under this warranty will not apply to the extent prohibited by applicable law.
This warranty covers only replacement or repair of defective Products or parts thereof at the Company’s main facility and does not include the cost of field
service travel and living expenses.
Any assistance the Company provides to or procures for you outside the terms, limitations or exclusions of this limited warranty will not constitute a waiver
of such terms, limitations or exclusions, nor will such assistance extend or revive the warranty. The Company will not reimburse you for any expenses
incurred by you in repairing or replacing any defective Product, except for those incurred with the Company’s prior written permission.
How to Obtain Warranty Service: To qualify for warranty service, you must (a) notify the Company at the address or telephone number stated below within
seven (7) days of discovering the covered defect, (b) give the model number and part identification and (c) describe the nature of any defect in the Product
or part. At the time of requesting warranty service, you must present evidence of the original purchase date. If you cannot provide a copy of the original
written limited warranty, then the terms of the Company’s most current written limited warranty for your particular product will control.
PRODUCT SPECIFICATIONS
All illustrations and specifications in this catalog are based on the latest product information available at time of production. Broan-NuTone, LLC and
BEST® reserves the right to make changes at any time, without notice, in prices, colors, materials, equipment, specifications and models, place of
manufacture and to discontinue models or equipment.
Best
Broan-NuTone, LLC- 926 W. State Street, Hartford, WI 53207 1-800-637-1453
Best®, 550 Lemire Blvd., Drummondville, QC, Canada (1-866-737-7770) www.bestrangehoods.com
SÉRIE WCP3I
HB0311
GUIDE D'INSTALLATION
BEST; Hartford, Wisconsin www.BestRangeHoods.com 800 558-1711
BEST; Drummondville, QC, Canada www.BestRangeHoods.ca 866 737-7770
23863 rév. 03
CONÇUE POUR USAGE RÉSIDENTIEL SEULEMENT
INSTALLATEUR : LAISSER CE GUIDE AU PROPRIÉTAIRE.
PROPRIÉTAIRE : DIRECTIVES D’UTILISATION ET D’ENTRETIEN
AUX PAGES 12 ET 13.
LIRE ET CONSERVER CES DIRECTIVES
! !
2
AFIN DE RÉDUIRE LES RISQUES D’INCENDIE,
D’ÉLECTROCUTION OU DE BLESSURES CORPORELLES,
SUIVEZ LES DIRECTIVES CI-DESSOUS :
1. N’utilisez cet appareil que de la façon prévue par le
manufacturier. Si vous avez des questions, contactez le
manufacturier à l’adresse ou au numéro de téléphone indiqués
dans la garantie.
2. Avant de réparer ou de nettoyer l’appareil, couper l’alimentation
électrique en verrouillant le panneau de distribution afin
d’éviter sa remise en marche accidentelle. Si le panneau de
distribution ne peut être verrouillé, y fixer un avertissement en
évidence, telle qu’une étiquette de couleur vive.
3. Les travaux d’installation et de raccordement électrique doivent
être effectués par une personne qualifiée, conformément
aux codes et aux standards de construction, incluant ceux
concernant la protection contre les incendies.
4. Une quantité d’air adéquate est requise afin d’assurer une
bonne combustion et l’évacuation des gaz par la cheminée
dans le cas des équipements alimentés au gaz afin de
prévenir les retours de cheminée. Suivez les instructions et
conformez-vous aux standards de sécurité des manufacturiers
d’équipement de chauffage, tel qu’ils sont publiés par la
National Fire Protection Association (NFPA) et l’American
Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE) ainsi que les responsables des
codes locaux.
5. Veillez à ne pas endommager le câblage électrique ou d’autres
équipements non apparents lors de la découpe ou du perçage
du mur ou du plafond.
6. Les ventilateurs avec conduits doivent toujours évacuer l’air
à l’extérieur.
7. Ne pas utiliser cet appareil avec une commande de vitesse à
semi-conducteur additionnelle.
8. Afin de réduire les risques d’incendie, n’utilisez que des conduits
de métal.
9. Cet appareil doit être mis à la terre.
10. Lorsqu’une réglementation est en vigueur et qu’elle comporte
des exigences d’installation et/ou de certification plus
restrictives, lesdites exigences prévalent sur celles de ce
document et l’installateur entend s’y conformer à ses frais.
AFIN DE RÉDUIRE LES RISQUES DE FEU DE
CUISINIÈRE :
a) Ne jamais laisser les appareils de cuisson sans surveillance
lorsqu’ils sont réglés à feu vif. Les débordements engendrent
de la fumée et des déversements graisseux pouvant
s’enflammer. Chauffez l’huile lentement, à feu doux ou moyen.
b) Mettez toujours la hotte en marche lorsque vous cuisinez à feu
vif ou que vous cuisinez des mets flambés (par ex. : crêpes
Suzette, cerises jubilées, steaks au poivre flambés).
c) Nettoyez régulièrement le ventilateur. Ne laissez pas la graisse
s’accumuler sur le ventilateur, les filtres ou les conduits
d’évacuation.
d) Utilisez le bon format de casserole. Servez-vous toujours de
casseroles et d’ustensiles appropriés à la dimension de la
surface chauffante.
1. Pour une utilisation à l’intérieur seulement.
2. Pour usage domestique seulement. Ne pas utiliser pour évacuer
des vapeurs ou des matières dangereuses ou explosives.
3. Afin d’éviter tout dommage au moteur ou de déséquilibrer
ou de rendre bruyante la roue du moteur, garder votre
appareil à l’abri des poussières de gypse et de construction/
rénovation,etc.
4. Le moteur de votre hotte possède une protection thermique
qui arrêtera automatiquement le moteur s’il surchauffe. Le
moteur redémarrera automatiquement une fois refroidi. Si le
moteur continue à arrêter et à redémarrer, faites-le vérifier.
5. Pour une meilleure évacuation des odeurs de cuisson, le
bas de votre hotte devrait être situé à un minimum de 24 po
(30 po pour une cuisinière à gaz) et à un maximum de 30 po
au-dessus de la table de cuisson.
6. Deux installateurs sont recommandés lors de l’installation vu
la grande dimension et le poids de cette hotte.
7. Afin de réduire les risques d’incendie, assurez-vous d’évacuer
l’air à l’extérieur. Ne pas évacuer l’air dans des espaces
restreints comme l’intérieur des murs ou plafonds ou dans le
grenier, faux plafond ou garage.
8 En raison de la grande capacité d’évacuation de cette hotte,
il est recommandé d’ouvrir une fenêtre dans ou près de la
cuisine afin de remplacer l’air évacué.
9. Afin de réduire les risques d’incendie et d’électrocution, la
hotte Best de la série WCP3I ne doit être installée qu'avec son
ventilateur intérieur intégré.
10. Afin de réduire les risques de feu ou d'électrocution, si la
hotte est utilisée en mode recirculation, utiliser uniquement
l'ensemble de recirculation modèle HRKBSS.
11. Veuillez consulter l’autocollant apposé à l’intérieur de la hotte
pour plus d’information ou autres exigences.
AVERTISSEMENT
!
ATTENTION
AVERTISSEMENT
!
AFIN D’ÉVITER TOUT RISQUE DE BLESSURES LORS
D’UN FEU DE CUISINIÈRE, SUIVEZ CES DIRECTIVES* :
1. Étouffez les flammes avec un couvercle hermétique,
une tôle à biscuits ou un plateau métallique et ensuite,
éteindre le brûleur. PRENEZ SOIN D’ÉVITER LES
BRÛLURES. SI LES FLAMMES NE S’ÉTEIGNENT PAS
IMMÉDIATEMENT, ÉVACUEZ LES LIEUX ET APPELEZ
LES POMPIERS.
2. NE PRENEZ JAMAIS UNE CASSEROLE EN FLAMMES
DANS VOS MAINS. Vous pourriez vous brûler.
3. N’UTILISEZ PAS D’EAU, incluant un linge à vaisselle ou une
serviette mouillée, cela pourrait occasionner une violente
explosion de vapeur.
4. N’utilisez un extincteur QUE DANS LE CAS OÙ :
A. Vous savez qu’il s’agit d’un extincteur de classe ABC et
que vous en connaissez le fonctionnement.
B. Le feu est petit et limité
à l’endroit où il a débuté.
C. Les pompiers ont été avisés.
D. Vous pouvez combattre le feu en ayant accès à une sortie
de secours.
*Tirées du Kitchen Fire Safety Tips publié par la NFPA.
3
HH0246F
CONDUIT DE
PO X 10 PO
OU 6 PO ROND
CAPUCHON DE TOIT
CONDUIT DE
PO X 10 PO
CAPUCHON
MURAL
HOTTE
CONDUIT
DÉCORATIF
VOIR LE TABLEAU
POUR
LA DISTANCE
AU-DESSUS DU
PLAN DE CUISSON
Avant de commencer l'installation de la hotte, retirer le support d'expédition (en gris),
ainsi que les vis qui le retiennent à la hotte et s'en défaire. Voir l'illustration de droite.
HD0937
EMPLACEMENT
DES VIS
1. PRÉPARER L'INSTALLATION
AVERTISSEMENT
!
Il est recommandé de porter des lunettes et des gants de sécurité lors de l’installation, de l’entretien et de la
réparation de cet appareil.
HAUTEUR DU PLAFOND
DISTANCE MINIMALE DE LA HOTTE
AU
-DESSUS DE LA SURFACE DE CUISSON
D'UNE CUISINIÈRE ÉLECTRIQUE
DISTANCE MINIMALE DE LA HOTTE
AU-DESSUS DE LA SURFACE DE
CUISSON D'UNE CUISINIÈRE À GAZ
8 PIEDS 24 POUCES 30 POUCES
9 PIEDS 28½ POUCES 30 POUCES
10 PIEDS* 28½ POUCES 30 POUCES
* Une rallonge de conduit décoratif est requise pour les plafonds de 10 pi, modèle AEWCP3SB (vendue séparément).
NOTE : Avant de commencer l'installation, vérifier le contenu de la boîte. Si des pièces sont manquantes ou endommagées, contacter le
manufacturier.
S'assurer que les articles suivants sont inclus :
- Hotte
- Accessoires • Ensemble de conduit décoratif (conduits inférieur et supérieur)
• Support de montage de la hotte
• Support de montage du conduit décoratif supérieur
• 2 filtres hybrides
Adaptateur/volet de 6 po rond (pour évacuation verticale), dans un sac à part
Adaptateur/volet de 3¼ po x 10 po (pour évacuation horizontale ou verticale)
• Sac de pièces comprenant : 5 vis à tête fraisée n° 8 x 1½ po, 8 vis n° 8 x 3/4 po, 6 vis n° 8 x 3/8 po, 6 douilles à
expansion, 3 rondelles, 2 vis n° 8 x 1/2 po, 2 morceaux de néoprène. Jeter la
quincaillerie excédentaire s'il y a lieu.
Pièces vendues séparément :
- Conduits, coudes, capuchons de mur ou de toit.
- Rallonge de conduit décoratif pour plafonds de 10 pi. modèle AEWCP3SB.
- Ensemble de recirculation modèle HRKBSS, obligatoire pour une installation en recirculation.
NOTE : La hauteur du plafond ne doit pas excéder 9 pi pour une installation sans conduit.
2. CHOISIR LE TYPE D'INSTALLATION
2.1 INSTALLATION EN RECIRCULATION
Un ensemble de recirculation modèle HRKBSS est requis pour ce type d'installation.
2.2 INSTALLATION AVEC CONDUITS
Déterminer à quel endroit et de quelle façon les conduits seront installés.
Installer des conduits de dimensions adéquates, des coudes et un capuchon de toit ou de
mur selon le type d’installation choisi.
Pour une évacuation verticale, utiliser des conduits ronds de 6 po ou des conduits de
3¼ po x 10 po et pour une évacuation horizontale,utiliser des conduits de 3¼ po x 10 po.
Se servir de ruban adhésif de métal pour assurer l’étanchéité des joints.
2.3 TOUTES LES INSTALLATIONS
La distance minimale entre le bas de la hotte et la surface de cuisson est de 24 po (30 po
au-dessus d'une cuisinière à gaz). Un maximum de 30 po au-dessus de la surface de
cuisson est recommandé pour une meilleure évacuation des odeurs de cuisson.
Les distances au-delà de 30 po sont à la discrétion de l’installateur et de l’utilisateur, si la
hauteur du plafond et du conduit décoratif le permettent.
NOTE : Lors de l'installation, protéger la surface de cuisson ou le comptoir de cuisine.
4
2. CHOISIR LE TYPE D'INSTALLATION (SUITE)
Se référer aux illustrations ci-dessous pour l’emplacement des conduits selon le type d’évacuation choisi (les pièces en gris seront
installées plus tard).
3. RETIRER LES FILTRES HYBRIDES
Poser la hotte à plat sur une table. Retirer les rubans adhésifs des filtres. Retirer les filtres en les
poussant vers le bas et en les dégageant de la hotte, puis les mettre de côté.
Retirer les deux morceaux de styromousse ainsi que le ruban adhésif d'en dessous du
ventilateur et s'en défaire.
3 PO
2
7
/8 PO
C
L
PO
HK0258F
14
15
/16 PO
17
15
/16 PO
HOTTE DE 30 PO DE LARGEUR
HOTTE DE 36 PO DE LARGEUR
PO
15/16 PO
12
7
/8 PO
14
15
/16 PO
C
L
PO
HK0273F
6
7
/16 PO
17
15
/16 PO
HOTTE DE 30 PO DE LARGEUR
HOTTE DE 36 PO DE LARGEUR
PO
C
L
HK0261F
14
15
/16 PO
17
15
/16 PO
HOTTE DE 30 PO DE LARGEUR
HOTTE DE 36 PO DE LARGEUR
6 PO DIA.
HD1099
2
1
ÉVACUATION VERTICALE OU INSTALLATION EN RECIRCULATION
ÉVACUATION VERTICALE
ÉVACUATION HORIZONTALE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Best WCP3I30SB Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation
Ce manuel convient également à