• To reduce the risk of death, personal injury or property damage from fire, electric
shock, falling parts, cuts/abrasions, and other hazards please read all warnings and
instructions included with and on the fixture box and all fixture labels.
• Before installing, servicing, or performing routine maintenance upon this equipment,
follow these general precautions.
• Installation and service of luminaires should be performed by a qualified licensed
electrician.
• Maintenance of the luminaires should be performed by person(s) familiar with the
luminaires’ construction and operation and any hazards involved. Regular fixture
maintenance programs are recommended.
• It will occasionally be necessary to clean the outside of the refractor/lens. Frequency
of cleaning will depend on ambient dirt level and minimum light output which is
acceptable to user. Refractor/lens should be washed in a solution of warm water and
any mild, non-abrasive household detergent, rinsed with clean water and wiped dry.
Should optical assembly become dirty on the inside, wipe refractor/lens and clean in
above manner, replacing damaged gaskets as necessary.
DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly
packed so that no parts should have been damaged during transit. Inspect to confirm.
Any part damaged or broken during or after assembly should be replaced.
• Recycle: For information on how to recycle LED electronic products, please visit
www.epa.gov.
• These instructions do not purport to cover all details or variations in equipment nor to
provide every possible contingency to meet in connection with installation, operation,
or maintenance. Should further information be desired or should particular problems
arise which are not covered suffi ciently for the purchaser’s or owner’s purposes, this
matter should be referred to Acuity Brands Lighting, Inc.
WARNING RISK OF ELECTRIC SHOCK
• Disconnect or turn off power before installation or servicing.
• Verify that supply voltage is correct by comparing it with the luminaire label
information.
• Make all electrical and grounded connections in accordance with the National
Electrical Code (NEC) and any applicable local code requirements.
• All wiring connections should be capped with UL approved recognized
wire connectors.
• Luminaires wiring, power supply, or other electrical parts may be damaged when
drilling for installation of retrofi t assembly hardware. Inspect wiring and components
for damage.
CAUTION RISK OF INJURY
• Wear gloves and safety glasses at all times when removing luminaire from carton,
installing, servicing or performing maintenance.
• Avoid direct eye exposure to the light source while it is on.
WARNING RISK OF BURN
• Allow lamp/fi xture to cool before handling. Do not touch enclosure or light source.
• Do not exceed maximum wattage marked on luminaire label.
• Follow all manufacturer’s warnings, recommendations and restrictions for: driver
type, burning position, mounting locations/methods, replacement and recycling.
CAUTION RISK OF FIRE
• Keep combustible and other materials that can burn, away from lamp/lens.
• Do not operate in close proximity to persons, combustible materials or substances
affected by heat or drying.
• Install this kit only in the luminaires that has the construction features and dimensions
shown in the photographs and / or drawings and where the input rating of the retrofi t
kit does not exceed the input rating of the luminaire.
CAUTION: RISK OF PRODUCT DAMAGE
• Never connect components under load.
• Do not mount or support these fi xtures in a manner that can cut the outer jacket or
damage wire insulation.
• Never connect an LED product to an unapproved dimmer pack. Contact ABL
directly for any dimmers not specifi cally recommended for the product.
• Unless individual product specifi cations deem otherwise: Allow for some volume of
airspace around fi xture. Avoid covering LED fi xtures with insulation, foam, or other
material that will prevent convection or conduction cooling.
• Unless individual product specifi cations deem otherwise: Maximum ambient
temperature is 90°C. Do not operate fi xture at temperatures higher than this.
• Unless individual product specifi cations deem otherwise: Never mount in places
where fi xture will be exposed to rain, high humidity, extreme temperature changes or
restricted ventilation.
• LED products are Polarity Sensitive. Ensure proper Polarity before installation.
• Electrostatic Discharge (ESD): ESD can damage LED fi xtures. Personal grounding
equipment must be worn during all installation or servicing of the unit.
• Do not touch individual electrical components as this can cause ESD, shorten lamp
life, or alter performance.
• There are no user serviceable parts inside the unit. Do not rewire, reconfi gure, or
modify the unit or attempt any repairs yourself. Additionally, fi eld replacement of the
LED assembly or lamps is not allowed by UL standards at this time. In the unlikely
event your unit may require service, stop using the unit immediately and contact an
ABL representative.
All luminaires that contain electronic devices that generate frequencies above 9kHz from
any component within the luminaire comply with one of the following Part 15 of the FCC
Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference
(2) This device must accept any interference received, including interference that may
cause undesired operation.
This device complies with Part 18 of the FCC Rules but may cause interference with
cordless and cell phones, radios, televisions, and other electronic devices. To correct
the problem move the device away from the luminaire or plug into a different outlet.
This product may cause interference to radio equipment and should not be installed
near maritime safety communications equipment or other critical navigation or
communications equipment operating between 0.45-30MHz.
Failure to follow any of these instructions could void product warranties.
For a complete listing of product Terms and Conditions, please visit
www.acuitybrands.com.
OUR BRANDS
Indoor/Outdoor: Lithonia Lighting, Carandini, Holophane, RELOC
Indoor Lighting: Gotham, Mark Architectural Lighting, Peerless, Renaissance
Lighting, Winona Lighting
Outdoor Lighting: American Electric Lighting, Antique Street Lamps, Hydrel, Tersen
Controls: DARK TO LIGHT, Lighting Control & Design, ROAM, Sensor Switch, Synergy
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising
out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
LED IMPORTANT SAFETY INSTRUCTIONS
LIRE ATTENTIVEMENT ET OBSERVER TOUTES LES CONSIGNES DE SÉCURITÉ
CONSERVER CES DIRECTIVES ET LES REMETTRE AU PROPRIÉTAIRE APRÈS
L’INSTALLATION
• Pour réduire les risques de décès, blessures ou dommages matériels résultant d’un incendie, d’un
choc électrique, de chutes de pièces, coupures, érafl ures et autres dangers, veuillez lire tous les
avertissements et toutes les directives fournis avec l’appareil, sur la boîte et les étiquettes.
• Avant l’installation, l’entretien ou la maintenance de cet équipement, veuillez prendre les précautions
générales suivantes.
• L’installation et le service technique des luminaires doivent être effectués par un électricien
licencié qualifi é.
• L’entretien des luminaires doit être effectué par des personnes au courant de la construction et du
fonctionnement des luminaires et des risques impliqués. Un programme d’entretien régulier est
recommandé.
• À l’occasion, il sera nécessaire de nettoyer l’extérieur du réfracteur ou de la lentille. La fréquence
de nettoyage dépendra du niveau de saleté ambiant et du fl ux lumineux minimal acceptable pour
l’utilisateur. Le réfracteur et la lentille doivent être nettoyés à l’aide d’une solution d’eau tempérée et de
tout détergent domestique doux, non abrasif, puis rincés à l’eau propre et essuyés. En cas de saleté à
l’intérieur du bloc optique, essuyer le réfracteur ou la lentille, puis nettoyer comme indiqué ci-dessus
et remplacer toute garniture d’étanchéité endommagée au besoin.
NE PAS INSTALLER UN PRODUIT ENDOMMAGÉ ! Ce luminaire a été emballé de manière
à ce que les pièces ne subissent pas de dommages lors du transport. Veuillez inspecter et confi rmer
le bon état. Toute pièce endommagée ou brisée lors de l’assemblage ou après devrait être remplacée.
• Recyclage : pour accéder à l’information sur le recyclage des produits électroniques DEL, veuillez
visiter www.epa.gov.
• Ces directives n’entendent pas couvrir tous les détails, tous les modèles d’équipement, ni prévoir
toute éventualité liée à l’installation, au fonctionnement ou à l’entretien de cet équipement. Pour toute
autre information ou en cas d’un problème non résolu par le présent document, l’acheteur ou le
propriétaire est prié de contacter Acuity Brands Lighting, Inc.
AVERTISSEMENT RISQUE DE CHOC ÉLECTRIQUE
• Couper ou éteindre l’alimentation électrique avant l’installation ou l’entretien.
• Vérifi er que la tension d’alimentation est adéquate en la comparant à l’information sur l’étiquette
du luminaire.
• Effectuer toutes les connexions et la mise à la terre conformément au National Electrical Code (NEC)
et aux exigences de tout autre code local applicable.
• Toutes les connexions doivent être protégées d’un capuchon de connexion homologué UL.
• Câblage de luminaires, d’alimentation ou d’autres pièces électriques peuvent être endommagés
lors du perçage pour l’installation du matériel de rénovation de l’Assemblée. Inspecter le câblage et
composants pour les dommages.
MISE EN GARDE RISQUE DE BLESSURE
• Porter des gants et des verres de sécurité en tout temps pour retirer le luminaire de la boîte,
l’installation, l’entretien ou les travaux de maintenance.
• Éviter d’exposer directement les yeux à la source lumineuse lorsqu’allumée.
AVERTISSEMENT RISQUE DE BRÛLURE
• Permettre le refroidissement de la lampe et du luminaire avant la manipulation. Ne pas toucher au
boîtier ou à la source lumineuse.
• Ne pas dépasser la puissance maximale indiquée sur l’étiquette du luminaire.
• Observer tous les avertissements, toutes les recommandations et toutes les restrictions du fabricant
sur : le type de pilote, la position d’utilisation, l’emplacement et les méthodes de montage, le
remplacement et le recyclage.
MISE EN GARDE RISQUE D’INCENDIE
• Éloigner toutes les matières combustibles ou infl ammables de la lampe et de la lentille.
• Ne pas employer à proximité des personnes, des matières combustibles ou des substances
sensibles à la chaleur ou la sécheresse.
• Installez ce kit uniquement dans les appareils d’éclairage qui a les caractéristiques de construction et
les dimensions indiquées dans les photographies et/ou dessins et où la puissance calorifi que du kit
de rattrapage n’excède pas la puissance calorifi que de l’appareil.
MISE EN GARDE : RISQUE DE CAUSER DES DOMMAGES AU PRODUIT
• Ne jamais connecter des composantes en charge.
• Ne pas monter ou supporter ces appareils d’une manière pouvant causer l’abrasion de la gaine
externe ou endommager l’isolant des fi ls.
• Ne jamais connecter un produit DEL à un dispositif de gradation non approuvé. Veuillez contacter
ABL directement pour vérifi er la compatibilité d’un gradateur non recommandé précisément pour
le produit.
• Sauf en cas de spécifi cations contraires individuelles des produits : Permettre un espace libre suffi
sant autour du luminaire. Éviter de couvrir les appareils DEL d’un matériau isolant, alvéolaire ou tout
autre matériau empêchant le refroidissement de l’unité par convexion ou conduction.
• Sauf en cas de spécifi cations contraires individuelles des produits : La température ambiante
maximale est 90 °C. Ne pas employer le luminaire à une température plus élevée.
• Sauf en cas de spécifi cations contraires individuelles des produits : Ne pas monter le luminaire
où il sera exposé à la pluie, l’humidité élevée, les changements de température extrêmes ou une
aération limitée.
• Les produits DEL sont sensibles à la polarité. S’assurer d’une polarité adéquate avant l’installation.
• Décharge électrostatique (DES) : Une DES peut endommager les appareils DEL. Un équipement de
mise à la terre de protection individuelle doit être porté lors de l’installation ou l’entretien de l’unité.
• Ne pas toucher aux composantes électriques individuelles, car cela peut causer une DES, réduire la
durée de vie de la lampe ou compromettre la performance de l’unité.
• Aucune pièce ne doit être réparée par l’utilisateur. Ne pas recâbler, reconfi gurer, modifi er ou réparer
l’unité. De plus, le remplacement sur place du groupe DEL ou des lampes n’est pas permis par UL
pour le moment. Dans le cas peu probable où l’unité exige un service technique, cesser de l’utiliser
et contacter le représentant ABL.
Tous les luminaires comportant des dispositifs électroniques émetteurs de fréquences supérieures à
9 kHz de toute composante du luminaire se conforment à l’une des règles de la FCC, Section 15. Le
fonctionnement est soumis aux deux conditions suivantes :
(1) Ce dispositif ne peut causer de perturbations nuisibles.
(2) Ce dispositif peut accepter toute perturbation reçue, notamment les perturbations pouvant
causer un fonctionnement indésirable.
Ce dispositif est conforme à la Section 18 des règles de la FCC, mais peut causer de l’interférence
avec les téléphones sans fi l ou cellulaires, radios, téléviseurs et autres dispositifs électroniques.
Pour corriger un problème, éloigner le dispositif du luminaire ou le brancher dans une autre prise de
courant. Ce produit peut causer de l’interférence à l’équipement radio, ne pas l’installer à proximité
de l’équipement de communications de la sécurité maritime ou tout autre équipement critique de
navigation ou de communications fonctionnant entre 0,45 et 30 MHz.
Ne pas observer ces instructions pourrait annuler les garanties du produit. Pour une
liste complète des conditions et modalités, veuillez visiter www.acuitybrands.com.
NOS MARQUES
Intérieur/Extérieur: Lithonia Lighting, Carandini, Holophane, RELOC
Éclairage intérieur: Gotham, Mark Architectural Lighting, Peerless, Renaissance Lighting, Winona
Lighting
Éclairage extérieur: American Electric Lighting, Antique Street Lamps, Hydrel, Tersen
Commandes d’éclairage: DARK TO LIGHT, Lighting Control & Design, ROAM, Sensor Switch, Synergy
Acuity Brands Lighting, Inc. décline toute responsabilité pour les réclamations
résultant d’une installation ou manipulation inadéquate ou négligente de ses
produits.
Avertissements généraux de ABL sur les produits DEL, pub. no 503.203
© 2010 Acuity Brands Lighting, Inc. Tous droits réservés. 12/01/10
IMPORTANTES CONSIGNES DE
SÉCURITÉ SUR L’ÉCLAIRAGE DEL
LEA Y RESPETE TODAS LAS INSTRUCCIONES DE INSTALACIÓN
GUARDE LAS INSTRUCCIONES Y DEVUÉLVALAS AL PROPIETARIO
DESPUÉS DE REALIZAR LA INSTALACIÓN
• Para reducir el riesgo de muerte, lesiones personales o daño a la propiedad que pueda surgir de
incendios, choques eléctricos, cortes, abrasiones, caída de partes y otros peligros lea todas las
advertencias e instrucciones incluidas en la caja o su interior, además de las etiquetas del montaje.
• Antes de instalar, revisar o realizar el mantenimiento de rutina del equipo, siga estas precauciones
generales.
• La instalación y el mantenimiento de las luminarias lo debe realizar un electricista califi cado
autorizado.
• El mantenimiento de las luminarias lo debe realizar una persona familiarizada con la fabricación
y el funcionamiento de este producto así como con los peligros relacionados con este. Se
recomienda realizar el mantenimiento regular de los montajes.
• Cada tanto será necesario limpiar la parte externa del refractor y de la lente. La frecuencia de la
limpieza dependerá del nivel de polvo del ambiente y de la potencia de la luz mínima aceptable
para el usuario. El refractor/la lente se debe lavar con una solución de agua tibia y detergente
de uso doméstico suave no abrasivo, enjuagar con agua limpia y secar. Si el montaje óptico se
ensuciara por dentro, limpie el refractor o la lente como se indicó anteriormente; de ser necesario,
reemplace las juntas dañadas.
NO INSTALE EL PRODUCTO SI ESTÁ DAÑADO Esta luminaria se embaló adecuadamente
de modo tal que las piezas no resulten dañadas durante su transporte. Inspecciónelas para
confi rmarlo. Reemplace toda pieza que se dañe o rompa durante su montaje o posterior a este.
• Reciclado: Para obtener información sobre cómo reciclar productos electrónicos LED, visite
www.epa.gov.
• Estas instrucciones no pretenden cubrir todos los detalles o las variaciones de los equipos ni
abarcar todas las posibles eventualidades relacionadas con la instalación, el funcionamiento o
el mantenimiento. Si necesita más información o surgen problemas específi cos que no están
debidamente cubiertos en la información del producto, remítase a Acuity Brands Lighting, Inc.
ADVERTENCIA: RIESGO DE CHOQUE ELÉCTRICO
• Desconecte o interrumpa la energía eléctrica antes de realizar la instalación o la reparación.
• Verifi que que el voltaje de alimentación sea correcto; compárelo con la información de la etiqueta
de la luminaria.
• Realice todas las conexiones eléctricas y a tierra en cumplimiento con el Código Eléctrico
Nacional y de los requisitos del código local vigente.
• Todas las conexiones de cableado deben cubrirse con conectores para cable
reconocidos y aprobados por UL.
• Cableado de luminarias, fuente de alimentación u otras partes eléctricas pueden
dañarse durante la perforación para la instalación de hardware para montaje.
Inspeccione el cableado y los componentes de los daños.
PRECAUCIÓN: RIESGO DE LESIONES
• Use gafas y guantes de protección en todo momento al retirar la luminaria de la caja, al instalarla,
repararla o realizar operaciones de mantenimiento.
• Una vez encendida la fuente de luz, evite la exposición directa con los ojos.
ADVERTENCIA: RIESGO DE QUEMADURAS
• Antes de manipular la lámpara o el montaje, déjelo enfriar. No toque la carcasa ni la fuente de
iluminación.
• No supere el voltaje máximo señalado en la etiqueta de la luminaria.
• Respete todas las advertencias, recomendaciones y restricciones que proporciona el fabricante
para: tipo de conductor, posición de funcionamiento, puntos o métodos de montaje, reemplazo
y reciclado.
PRECAUCIÓN: RIESGO DE INCENDIO
• Mantenga lejos de la luminaria y de las lámparas o los lentes, los materiales combustibles y de
otro tipo que se puedan incendiar.
• No las encienda cerca de personas, materiales combustibles o sustancias calientes o secas.
• Instale este kit solamente en las luminarias que tiene las características de
construcción y dimensiones que se muestran en las fotografías o dibujos y donde la
entrada del kit para reequipamiento posterior no exceder la entrada de la luminaria.
PRECAUCIÓN: RIESGO DE DAÑO PARA EL PRODUCTO
• Jamás conecte componentes bajo carga.
• No monte estos montajes de manera que puedan cortar el revestimiento exterior o dañar el
aislamiento de los cables.
• Jamás conecte un producto LED directamente a un paquete de reducción de intensidad de la luz.
Los montajes LED se deben apagar directamente de un circuito de interruptores.
• A menos que las especifi caciones del producto individual consideren lo contrario: Deje un poco
de espacio alrededor del montaje. Evite cubrir los montajes LED con aislación, goma u otro
material que evitará la convección o el enfriamiento de la conducción.
• A menos que las especifi caciones del producto individual consideren lo contrario: La temperatura
ambiente máxima debe ser de 90 °C. No haga funcionar el montaje a temperaturas más elevadas
que esta.
• A menos que las especifi caciones del producto individual consideren lo contrario: Jamás instale
los montajes en lugares donde queden expuestos a la lluvia, a un alto nivel de humedad, a
cambios de temperatura extrema o a ventilación limitada.
• Los productos LED son sensibles a la polaridad. Asegure la correcta polaridad antes de la
instalación.
• Descarga electrostática (DES): la DES puede dañar los montajes LED. Durante la instalación o
reparación de la unidad se debe usar siempre equipo personal conectado a tierra.
• No toque componentes eléctricos individuales ya que esto puede causar DES, reducir la vida útil
de la lámpara o alterar el funcionamiento.
• La unidad no contiene piezas que el usuario pueda reparar. No modifi que los
cables de la unidad, no la vuelva a confi gurar, no la modifi que ni intente repararla usted mismo.
Además, en este momento los estándares de UL no permiten el reemplazo en campo del montaje
LED o sus lámparas. En el caso improbable de que su unidad requiera reparación, deje de usar la
unidad inmediatamente y comuníquese con un representante de ABL.
Todas las luminarias que contienen dispositivos eléctricos que generan frecuencias superiores a
9kHz desde cualquier componente de la luminaria cumplen una de las reglas de la Parte 15 de las
reglas de la FCC. El funcionamiento depende de las siguientes dos condiciones:
(1) Este dispositivo no puede ocasionar interferencias perjudiciales
(2) Este dispositivo debe aceptar cualquier interferencia recibida, incluso, las interferencias que
pueden ocasionar un mal funcionamiento.
Este dispositivo cumple con la Parte 18 de las reglas de la FCC pero puede ocasionar interferencia
con teléfonos inalámbricos y celulares, radios, televisores y otros dispositivos electrónicos. Para
corregir el problema, aleje el dispositivo de la luminaria o enchúfelo en otra toma de corriente. Este
producto puede ocasionar interferencia en equipos de radio y no se debe instalar cerca de equipos
de comunicación de seguridad marítima u otros equipos de comunicación o navegación crítica que
funcionen en el rango 0.45-30MHz.
El incumplimiento de alguna de estas instrucciones puede anular la garantía del
producto. Para obtener la lista completa de los términos y las condiciones respecto
del producto, visite www.acuitybrands.com.
NUESTRAS MARCAS
Interior/Exterior: Lithonia Lighting, Carandini, Holophane, RELOC
Sistemas de iluminación para interior: Gotham, Mark Architectural Lighting, Peerless,
Renaissance Lighting, Winona Lighting
Sistemas de iluminación para exterior: American Electric Lighting, Antique Street Lamps,
Hydrel, Tersen
Controles: DARK TO LIGHT, Lighting Control & Design, ROAM, Sensor Switch, Synergy
Acuity Brands Lighting, Inc. no se hace responsable por los reclamos que puedan
surgir de la instalación o manipulación inadecuada o negligente de sus productos.
Advertencias generales de ABL LED, Form. n.º 503.203
© 2010 Acuity Brands Lighting, Inc. Todos los derechos reservados. 12/01/10
INSTRUCCIONES DE SEGURIDAD
IMPORTANTES SOBRE EL LED
Page 1 of 4
Part No. CJ520299
©2016 Acuity Brands Lighting, Inc., 01/16
Page 4 of 4
INSTALLATION INSTRUCTIONS - 65BEMW LED, 4BEMW LED,
&43BEMW LED
(6”, 5”, 4”, & 3” Baffl e LED Module)
FIVE YEAR LIMITED WARRANTY –
INDOOR LED ENERGY STAR QUALIFIED RESIDENTIAL
DOWNLIGHTING PRODUCTS
Subject to the exclusions set forth below, Acuity Brands Lighting, Inc.
(“Acuity”) warrants this Energy Star® qualifi ed Lithonia Lighting indoor
light emitting diode (LED) residential downlighting product (“LED Product”),
purchased from an authorized reseller, to be free from defects in material and
workmanship (the “Limited LED Warranty”) for a period of fi ve (5) years from
the date of purchase. The LED arrays in the LED Product will be considered
defective in material or workmanship only if the LED Product fails to operate
or if a total of 15% or more of the individual light emitting diodes in the LED
Product fail to illuminate.
If the LED Product fails to comply with the terms of this Limited LED Warranty,
Acuity will repair or replace the LED Product with the same or a functionally
equivalent LED Product or component part. If it is not commercially
practicable for Acuity to repair or replace the LED Product, Acuity will refund
to you the purchase price paid by you for the LED Product. This Limited
LED Warranty excludes labor required to remove and/or reinstall original
or replacement LED Product or component parts. The repair or replacement
of the LED Product or any component part is the sole and exclusive remedy
for failure of the LED Product to comply with the terms of this Limited LED
Warranty and does not extend the Limited LED Warranty period. Warranty
claims regarding the LED Product may be made by contacting our Post Sale
department at 1-800-315-4935 or [email protected] for a return
authorization and shipping instructions. You must provide proof of purchase
when making a warranty claim with us. Sales receipt or online registration
at lightahome.com are examples of acceptable proof of purchase. If we ask
you to return the product to us for repair or replacement, you will be required
to pay the cost of shipping the LED Product. In addition, you may also be
able to make a warranty claim regarding the LED Product by returning the
LED Product to your authorized reseller for replacement, refund or credit, in
accordance with its applicable return policy.
This Limited LED Warranty extends only to the LED Product at the original
installation location. This Limited LED Warranty applies only when the LED
Product is installed in applications in which ambient temperatures are within
the range of intended operating temperatures. Acuity will not be responsible
under this Limited LED Warranty for any failure of the LED Product that
is a result of external causes such as acts of nature; physical damage;
environmental conditions; vandalism; fi re; power failure, improper power
supply, power surges or dips, or excessive switching; induced vibration;
animal or insect activity; your fault or negligence or the fault or negligence
of anyone hired by you; improper or unauthorized use, installation, handling,
storage, alteration, maintenance or service or failure to comply with any
applicable codes and/or recommendations, product specifi cation sheets or
instructions of Acuity; failure resulting from use with non-Acuity products,
processes or materials; or any other occurrences beyond Acuity’s reasonable
control. This Limited LED Warranty does not apply to LED downlighting
products sold for commercial purposes, indoor residential LED downlighting
products that do not qualify for Energy Star ratings, or any other consumer or
commercial products, all of which are governed by separate limited warranty
terms.
EXCEPT AS EXPRESSLY PROVIDED IN THIS LIMITED LED WARRANTY,
ACUITY MAKES NO WARRANTIES OF ANY KIND WITH RESPECT TO THIS
PRODUCT, AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT
LIMITATION, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, ARE HEREBY EXPRESSLY LIMITED TO THE FIVE
(5) YEAR DURATION OF THIS LIMITED WARRANTY. ACUITY’S TOTAL
LIABILITY ARISING IN ANY MANNER IN CONNECTION WITH THIS LED
PRODUCT SHALL BE LIMITED TO THE AMOUNT OF THE PURCHASE
PRICE PAID BY YOU AND IN NO EVENT SHALL ACUITY BE LIABLE FOR
ANY INCIDENTAL, CONSEQUENTIAL, SPECIAL OR INDIRECT DAMAGES,
INCLUDING, WITHOUT LIMITATION, LOSS OF PROFITS OR REVENUES OR
LOSS OF USE OF THIS LED PRODUCT.
NOTE: This warranty gives you specifi c legal rights and you may also
have other rights which vary from state to state. Some states do not allow
limitations on how long an implied warranty lasts or the exclusion or
limitation of incidental or consequential damages, so the above limitations
or exclusions may not apply to you.
Lithonia DownlighƟ ng
One Lithonia Way / Conyers, GA 30012
800-315-4935 / www.lithonia.com
INSTRUCTIONS D’INSTALLATION - 65BEMW LED, 4BEMW LED,
&43BEMW LED
(Module DEL avec déflecteur de 15,24 cm, 12,7 cm, 10,16 cm, & 7.62 cm)
GARANTIE LIMITÉE DE CINQ ANS CONCERNANT LES
PLAFONNIERS INTENSIFS D’INTÉRIEUR RÉSIDENTIEL
RÉPONDANT AUX EXIGENCES « ENERGY STAR »
Sous réserve des exclusions défi nies ci-dessous, la compagnie Acuity Brands
Lighting, Inc. (« Acuity ») garantit durant une période de cinq (5) ans à partir
de la date d’achat contre tout défaut de matériaux et de main d’oeuvre («
garantie limitée DEL ») le plafonnier intensif d’intérieur résidentiel de type diode
électroluminescente (« produit DEL ») « Lithonia » répondant aux exigences «
Energy Star® » dans la mesure où il a été procuré par un revendeur agréé. La
série de DEL sera considérée défectueuse en raison d’un défaut de matériaux ou
de fabrication seulement si le produit DEL ne fonctionne pas du tout ou, si un
nombre supérieur ou égal à 15 % des diodes électroluminescentes individuelles
du produit DEL ne s’allument pas.
Si le produit DEL n’est pas conforme aux conditions stipulées par la présente
garantie limitée DEL, Acuity s’engage à effectuer une réparation du produit, à
échanger le produit, à fournir un produit DEL ou une pièce de remplacement
de fonctionnalité équivalente. Dans l’éventualité où une réparation ou un
remplacement du produit s’avérerait commercialement impossible, Acuity
effectuera un remboursement intégral du produit DEL. La présente garantie DEL
exclut la main d’oeuvre susceptible d’être nécessaire au démontage et/ ou à la
réinstallation du produit DEL original ou de remplacement ainsi que des pièces
fournies. La réparation ou le remplacement du produit DEL ou de ses composants
représentent les seules options disponibles dans l’éventualité où le produit ne
serait pas conforme aux conditions stipulées par la présente garantie. Une telle
éventualité ne peut en aucun cas être invoquée pour prolonger la période de
couverture de cette garantie. Les réclamations concernant la garantie du produit
DEL peuvent être soumises en contactant directement notre service après-vente
par téléphone au : 1 800 315 49 35 ou en envoyant un courriel à l’adresse suivante:
[email protected] afi n d‘obtenir l’autorisation de renvoi ainsi que les
instructions d’emballage appropriées. Une preuve d’achat doit être fournie et
accompagner toute réclamation de garantie. Par exemple, un reçu ou une copie
de l’enregistrement du produit obtenue sur le site Web « lightahome.com »
constituent des preuves d’achat acceptables. Si nous acceptons de réparer ou de
remplacer le produit DEL, les frais d’envoi seront à votre charge exclusive. D’autre
part, une réclamation de garantie concernant le produit DEL est susceptible d’être
soumise directement auprès du revendeur agréé auquel cas, il se chargera de
remplacer, de rembourser ou de délivrer une note de crédit équivalente au produit
DEL considéré, en fonction de la politique de retour appliquée.
La présente garantie limitée s’applique uniquement au produit DEL à l’endroit
de l’installation d’origine. La présente garantie limitée s’applique uniquement
lorsque le produit DEL est installé dans un lieu de fonctionnement conforme
aux limites de températures ambiantes stipulées. Conformément à la présente
garantie limitée, Acuity ne sera pas tenu responsable des défaillances du
produit DEL résultant de causes externes telles que : les catastrophes naturelles,
les dommages physiques, les conditions environnementales, les actes de
vandalisme, les incendies, les pannes d’électricité, les défaillances du réseau
électrique, les fl uctuations de secteur, les commutations excessives, les vibrations
induites, l’activité des insectes, les erreurs ou les négligences de votre part ou
causées par toute personne que vous employez, une utilisation, installation,
maniement, stockage, modifi cation ou maintenance impropre ou non- autorisé,
le non respect des codes, normes et/ ou recommandations en vigueur, le non
respect des fi ches techniques et des instructions concernant le produit fourni par
Acuity, les défaillances résultant de l’utilisation conjointe de produits, processus
ou matériaux non fournis par Acuity ou tout autre évènement échappant au
contrôle raisonnable d’Acuity. La présente garantie limitée ne s’applique pas aux
plafonniers intensifs DEL vendus à des fi ns commerciales, aux autres plafonniers
intensifs DEL ne répondant pas aux exigences « Energy Star » ou à tout autre
produit de consommation courante ou d’utilisation commerciale, ceux-ci faisant
l’objet de conditions de garantie séparées.
À L’EXCLUSION DES CONDITIONS STIPULÉES PAR LA PRÉSENTE, ACUITY
NE FOURNIT AUCUNE AUTRE GARANTIE DE QUELQUE NATURE QUE CE SOIT
EN CE QUI CONCERNE CE PRODUIT. TOUTE AUTRE GARANTIE IMPLICITE, Y
COMPRIS ET SANS EN EXCLURE D’AUTRES, CELLES CONCERNANT LA VALEUR
MARCHANDE OU L‘ADAPTATION À DES FINS PARTICULIÈRES SONT LIMITÉES
EXPRESSÉMENT À UNE DURÉE DE CINQ (5) ANS. LA RESPONSABILITÉ
D’ACUITY DÉCOULANT DE QUELQUE FAÇON QUE CE SOIT DE LA PRÉSENTE
GARANTIE DE CE PRODUIT DEL SERA LIMITÉE À LA SOMME QUE VOUS AVEZ
PAYÉE. EN AUCUN CAS ACUITY NE POURRA ÊTRE TENU RESPONSABLE DE
DOMMAGES ACCIDENTELS, ACCESSOIRES, SPÉCIAUX OU INDIRECTS, Y
COMPRIS ET SANS EN EXCLURE D’AUTRES, LES PERTES DE REVENUS OU DE
PROFITS OU LES PERTES D’EXPLOITATION DE CE PRODUIT DEL.
Remarque : cette garantie vous octroie certains droits légaux. Vous êtes
susceptibles de bénéfi cier d’autres droits légaux pouvant varier d’un État à l’autre.
Certains États ne limitent pas la durée d’une garantie implicite, ni n’excluent ou ne
restreignent les dommages accessoires ou indirects de sorte que les restrictions
INSTRUCCIONES DE INSTALACIÓN - 65BEMW LED, 4BEMW LED,
&43BEMW LED
(Módulo led defl ector de 15,24 cm, 12,7 cm, 10,16 cm, & 7.62cm)
GARANTÍA LIMITADA POR 5 AÑOS: PRODUCTOS LED
DE ILUMINACIÓN DIRECTA PARA USO RESIDENCIAL EN
INTERIORES CON CERTIFICACIÓN ENERGY STAR
Sujeto a las excepciones establecidas a continuación, Acuity Brands
Lighting, Inc. (“Acuity”) garantiza que este producto de iluminación directa
a través de diodos emisores de luz (LED) para uso residencial en interiores
(“Producto LED”) de Lithonia Lighting certifi cado por Energy Star®,
adquirido de un distribuidor autorizado, no tendrá defectos de material o
mano de obra (la “Garantía LED limitada”) por un período de cinco (5) años
a partir de la fecha de compra. Se considerará que las matrices LED del
Producto LED tienen defectos de material o mano de obra sólo si el Producto
LED no funciona o si un total del 15% o más de los diodos emisores de luz
individuales del Producto LED no se encienden.
Si el Producto LED no cumple con los términos de esta Garantía LED
limitada, Acuity reparará o reemplazará el Producto LED por el mismo
Producto LED o una parte del componente o producto operativamente
equivalente. Si no fuese comercialmente viable para Acuity la reparación o el
reemplazo del Producto LED, Acuity le reintegrará el precio de compra que
usted desembolsó por el Producto LED. Esta Garantía LED limitada excluye
la mano de obra requerida para remover o reinstalar el Producto LED original
o de reemplazo o partes de este. La reparación o reemplazo del Producto LED
o cualquier parte de este es el único y exclusivo recurso en caso de que el
Producto LED no cumpla con los términos de esta Garantía LED limitada y
no extiende el período de dicha Garantía. Los reclamos de la garantía con
respecto al Producto LED pueden hacerse a través de nuestro departamento
de Post Venta llamando al 1-800-315-4935 o por escrito a PSGDR01@
acuitybrands.com para una autorización de devolución e instrucciones de
envío. Deberá proporcionar la constancia de compra al hacer un reclamo de
la garantía. El recibo de venta o registro en línea en la dirección lightahome.
com son formas aceptables de constancia de compra. En caso de que le
solicitemos que nos devuelva el producto para su reparación o reemplazo,
deberá cubrir el costo de envío del Producto LED. Además, puede hacer
cualquier reclamo de la garantía con respecto al Producto LED a través de la
devolución del Producto LED a su distribuidor autorizado para su reemplazo,
reintegro o crédito, conforme a su política de devolución aplicable.
Esta Garantía LED limitada abarca sólo el Producto LED en el lugar de
instalación original. Esta Garantía LED limitada se aplica solo en caso
de que el Producto LED sea instalado en aplicaciones en las que la
temperatura ambiente esté dentro del rango proyectado de temperaturas de
funcionamiento. Acuity no será responsable bajo esta Garantía LED limitada
de cualquier falla del Producto LED que resulte de causas externas, como
desastres naturales; daño físico; condiciones ambientales; vandalismo;
incendio; falla eléctrica, suministro eléctrico inadecuado, subidas o
caídas de voltaje, o conmutación excesiva; vibración inducida; actividades
de animales o insectos; error o negligencia suya o de cualquier persona
contratada por usted; uso, instalación, manipulación, almacenamiento,
alteración, mantenimiento o servicio inadecuado o desautorizado, o
incumplimiento de cualquier código o recomendación aplicable, hojas de
especifi cación del producto o instrucciones Acuity; falla provocada por el
uso con productos, procesos o materiales que no sean de Acuity; o cualquier
otra situación que escape del control razonable de Acuity. Esta Garantía LED
limitada no se aplica a productos LED de iluminación directa vendidos con
nes comerciales, productos LED de iluminación de uso residencial en
interiores que no se encuentren dentro de la clasifi cación de Energy Star, o
cualquier otro producto para distribución o comercial, que estén regulados
por términos individuales de garantías limitadas.
A EXCEPCIÓN DE LO ESTABLECIDO EXPRESAMENTE EN ESTA GARANTÍA
LED LIMITADA, ACUITY NO OFRECE NINGUNA GARANTÍA CON RESPECTO
A ESTE PRODUCTO, Y TODAS LAS GARANTÍAS IMPLÍCITAS, INCLUIDAS,
ENTRE OTRAS, GARANTÍAS DE COMERCIABILIDAD O IDONEIDAD
PARA UN PROPÓSITO EN PARTICULAR, SE LIMITAN EXPRESAMENTE
A LOS CINCO (5) AÑOS DE DURACIÓN DE ESTA GARANTÍA LIMITADA.
LA RESPONSABILIDAD TOTAL DE ACUITY QUE PUEDA SURGIR DE
CUALQUIER MANERA EN RELACIÓN CON ESTE PRODUCTO LED SE
LIMITARÁ AL MONTO DEL PRECIO DE COMPRA DESEMBOLSADO
POR USTED Y, EN NINGÚN CASO, ACUITY SERÁ RESPONSABLE POR
CUALQUIER DAÑO IMPREVISTO, DERIVADO, ESPECIAL O INDIRECTO,
INCLUIDAS, ENTRE OTROS, LA PÉRDIDA DE GANANCIAS O INGRESOS O
LA IMPOSIBILIDAD DE USO DE ESTE PRODUCTO LED.
NOTA: Esta garantía le otorga derechos legales y, además, usted puede
contar con otros derechos que varian dependiendo del estado. Algunos
estados no permiten limitaciones sobre la duración de cualquier garantía
implícita o la exclusión o limitación de daños imprevistos o derivados,
de manera que las limitaciones o exclusiones mencionadas anteriormente
E-SERIES LED RETROFIT DOWNLIGHT INSTALLATION INSTRUCTIONS
DISCONTINUED
Page 2 of 4
INSTALLATION INSTRUCTIONS - 65BEMW LED, 4BEMW LED, &
43BEMW LED
(6”, 5”, 4”, & 3” Baffl e LED Module)
Suitable for wet locations.
This device is not intended for use with emergency exits or emergency
lighting.
CAUTION - shock and fi re hazard. Do not use when enclosure is broken.
WARNING - risk of fi re or electric shock. Luminaires wiring, power supply,
or other electrical parts may be damaged when drilling for installation of
retrofi t assembly hardware. Inspect wiring and components for damage.
WARNING - risk of fi re or electric shock. Installation of this retrofi t
assembly requires a person familiar with the construction and operation of
the luminaire’s electrical system and the hazards involved. If not qualifi ed,
do not attempt installation, contact a qualifi ed electrician.
WARNING - risk of fi re or electric shock. Install this kit only in the
luminaires that has the construction features and dimensions shown in the
photograps and / or drawing and where the input rating of the retrofi t kit
does not exceed the input rating of the luminaire.
Do not make or alter any open holes in an enclosure of wiring or electrical
components during kit installation.
WARNING - to prevent wiring damage or abrasion, do not expose wiring to
edges of sheet metal or other sharp objects.
The retrofi t kit is accepted as a component of a luminaire where the
suitability of the combination shall be determined by CSA or authorities
having jurisdiction.
6”& 5” Matte White Baffl e LED Module, Model 65BEMW LED 27K M6,
65BEMW LED 30K M6 and 65BEMW LED 40K M6, Input 120V 60Hz, 0.10A,
12W.
4” Matte White Baffl e LED Module, Model 4BEMW LED 27K M6, 4BEMW
LED 30K M6 and 4BEMW LED 40K M6, Input 120V 60Hz, 0.09A, 10W.
3” Matte White Baffl e LED Module, Model 43BEMW LED 27K M6, 43BEMW
LED 30K M6, and 43BEMW LED 40K M6 Input 120V, 60Hz, 0.09A, 10W.
Each unit carton contains 1ea LED module, 1ea E26 adapter, 1ea GU10
adapter (43BEMW only), 1 ea connector, and 1ea Replacement Marking
Label (affi xed to the retrofi tted luminaire).
REQUIRED TOOLS (not included): safety glasses and gloves.
Step 1A: Torsion Spring Brackets (Model 65BEMW LED Only)
1. If necessary, remove the ballast and ensure the input power is 120V before
installation.
2. Loosen (2) Torsion Bracket mounting screws on top of module (Figure 1) to adjust
brackets and torsion springs to fi t and align with either a 6” or 5” recess housing
bracket-clips in ceiling.
3. Tighten Torsion Bracket mounting screws securely.
Note: The 65BEMW LED module only installs with the torsions springs, no other
mounting clips are provided.
Step 1B: Retention Spring Clips (Model 4BEMW LED Only)
1. If necessary, remove the ballast and ensure the input power is 120V before
installation.
Note: The 4BEMW LED module only installs with the retention springs, no other
mounting clips are provided.
Step 1C: Adjustable Retention Spring Clips (Model 43BEMW LED Only)
1. If necessary, remove the ballast and ensure the input power is 120V before
installation.
2. If needed to adjust to fi t different recess housing (can fi t any 3” to 4”) loosen (2)
Retention Spring Clip screws on top of module (Figure 1) and adjust clip to fi t and
align with any of 3” to 4” recesssed can.
Lithonia DownlighƟ ng
One Lithonia Way / Conyers, GA 30012
800-315-4935 / www.lithonia.com
3. Tighten Retention Spring Clips mounting screws securely.
Note: The 43BEMW LED module only installs with the retention springs, no other
mounting clips are provided.
Step 2: Grounding Wire
NOTE – DO NOT LET THE MODULE HANG UNSUPPORTED BY THE ORANGE
CONNECTOR (Figure 2)
A. Recessed housing with grounding wire:
1. Cut off the grounding wire eyelet from the LED module.
2. Pair the LED module’s bare copper grounding wire with the grounding wire from
the recessed housing and secure with a wire nut.
B. Recessed housing without grounding wire:
1. Install the grounding wire eyelet into a 8-18 x 3/8” screw (Lithonia Lighting
housings). Or,
2. Install the eyelet through an 8-18 or equivalent self-tapping screw and secure
into the housing wall.
Warning: risk of fi re or electric shock, read and follow all safety instructions. The retrofi t
must be grounded using the proper method as described above.
Step 3: Determine Wiring Method (Select one wiring method)
A. E26 Socket Adapter:
1. Screw E26 socket adapter into the base socket inside the housing.
2. Plug the orange connector of E26 socket adapter into the LED module’s mating
orange connector (see Figure 3). Or,
B. GU10 Adapter:
1. Twist GU10 adapter into the base socket inside the housing.
2. Plug the orange connector of GU10 adapter into the LED module’s mating orange
connector (see Figure 3). Or,
C. LED Connector:
1. Plug orange connector from the module into the mating orange connector in the
recessed housing. -This type of connection complies with Title 24 (permanent
LED installation).
Note: No Hardwire Connection Kit is supplied with module.
Step 4: Installation of the Module into the Recessed Housing
A. Torsion springs (Model 65BEMW LED Only): Squeeze each torsion spring together
and seat them inside the housing torsion brackets. Release springs, and gently push
module into housing until fl ush with ceiling (Figure 4).
B. Spring retention clips (Model 4BEMW LED & 43BEMW LED Only): Center the LED
module in the housing opening and gently push the module up into the housing
evenly on all sides until fl ush with ceiling (Figure 5).
NOTE:
• Align the two retention clips with the recessed housing avoiding interference with
anything protruding from the housing walls.
• For removal of a recessed LED module with retention clips, pull down and rotate
back and forth until free. Use two standard fl at blade screw drivers to pry the
module apart from the recessed housing. This will aid in the removal process.
_____________________________________________________________
RECOMMENDED DIMMING SWITCHES: The LED Modules are compatible with
several standard residential dimmers. A list of recommended dimmers can be found at
www.lithonia.com, keyword search 65BEMW, 4BEMW, or 43BEMW.. Exclusion from the
list does not mean a dimmer will not work in conjunction with your LED module. Consult
with your dimmer manufacturer regarding compatibility with LED modules/lamps.
RECESSED CAN COMPATIBILITY: Lithonia’s 65BEMW LED modules are tested to fi t in
a minimum enclosure of 5” diameter by 7” height, with a maximum fl ange diameter of 7.5”.
Lithonia’s 4BEMW LED modules are tested to fi t in a minimum enclosure of 4” diameter
by 6” height, with a maximum fl ange diameter of 5.25”. Lithonia’s 43BEMW LED modules
are tested to fi t in a minimum enclosure of 3” diameter by 4” height, with a maximum
ange diameter of 5.25”. For a list of compatible housings go to www.lithonialighting.com,
keyword search 65BEMW, 4BEMW, or 43BEMW.
LISTINGS: CSA certifi ed to US and Canadian safety standards; Energy Star qualifi ed;
California Title 24 compliant; damp location listed; and WSEC ASTEM E283 for Air-
Tight rated with IC housings. 65BEMW minimum lamp compartment 5 inches (127 mm)
diameters by 7 inches (180 mm) tall or minimum lamp compartment 137 in³ (2315cm³).
4BEMW minimum lamp compartment 4 inches (100 mm) diameters by 6 inches (150
mm) tall or minimum lamp compartment 75.4 in³ (1178 cm³). 43BEMW minimum lamp
compartment 3 inches (76 mm) diameters by 4 inches (102 mm) tall or minimum lamp
compartment 28.3 in³ (462 cm³). Use only in open luminaires. Suitable for Type IC or
Type Non-IC luminaires. The retrofi t kit is accepted as a component of a luminaries
where the suitability of the combination shall be determined by CSA or authorities having
jurisdiction.
PATENTS PENDING
Figure 5 / Figura 5 / Schéma 5
INSTRUCCIONES DE INSTALACIÓN - 65BEMW LED, 4BEMW LED, &
43BEMW LED
(Módulo led defl ector de 15,24 cm, 12,7 cm, 10,16 cm, & 7,62 cm)
Apto para lugares húmedos.
Este dispositivo no está diseñado para uso con salidas de emergencia o no
para la iluminación de emergencia.
PRECAUCIÓN - choque y peligro de incendio, no utilice cuando la caja está
quebrado.
ADVERTENCIA - riesgo de incendio o descarga eléctrica. Cableado de
luminarias, fuente de alimentación u otras partes eléctricas pueden dañarse
durante la perforación para la instalación de hardware para montaje.
Inspeccione el cableado y los componentes de los daños.
ADVERTENCIA - risego de incendio o descarga eléctrica. Luminarias de
cableado, fuente de alimentación, u otras partes eléctricas pueden resultar
dañados cuando perforación para la instalación de hardware asamblea
retrofi t. Controlar el cableado y componentes para daños.
ADVERTENCIA - risego de incendio o descarga eléctrica. Instalación de
esta asamblea retrofi t requiere una persona familiar con la construcción y
operación de sistema eléctrico del aparato y el peligro de involucrados. si
no está califi cado, no trate de instalación. pida a un electricista.
ADVERTENCIA - risego de incendio o descarga eléctrica. Instalar este
kit solo en los aparatos que tiene las carateristicas de construccion y
dimensions muestra en las fotografías y / o planos.
No haga o alterar los agujeros de puertas abiertas en una caja de cableado o
componentes eléctricos durante la instalación kit.
ADVERTENCIA - para evitar daños cableado o abrasión, no exponer el
cableado de bordes de chapa u otros objetos punzantes.
El kit se acepta como componente de un aparato donde la conveniencia de la
combinación será determinado por csa o autoridades competente.
6”y 5” Módulo Matte White Baffl e LED, Modelo 65BEMW LED 27K M6,
65BEMW LED 30K M6 y 65BEMW LED 40K M6, 60Hz 120V de entrada, 0.10A,
12W.
4” Módulo Matte White Baffl e LED, Model 4BEMW LED 27K M6, 4BEMW LED
30K M6 y 4BEMW LED 40K M6, 60Hz 120V de entrada, 0.09A, 10W.
3” Módulo Matte White Baffl e LED, Model 43BEMW LED 27K M6, 43BEMW
LED 30K M6, y 43BEMW LED 40K M6 60Hz 120V de entrada, 0.09A, 10W.
Cada caja unidad contiene módulo 1ea LED, adaptador E26 1ea, adaptador
GU10 1ea (43BEMW sólo), conector 1ea y 1ea reemplazo Marcado Label
(fi jida a la luminaria modernizado).
Harramientas necesarias (no se incluyen): gafas de seguridad y guantes.
Paso 1A: Soportes de resorte de torsión (Módelo 65BEMW LED)
1. Si es necesario, Quitar el lastre y asegurar la potencia de entrada es da 120 V antes
de la instalación.
2. Afl oje los (2) tornillos de montaje del soporte de torsión en la parte superior del
módulo (Figura 1) para ajustar los soportes y los resortes de torsión para adaptarlos
y alinearlos con los sujetadores de soporte de la caja empotrada de 6 in o 5 in en el
techo. Ajuste los tornillos de montaje del soporte de torsión.
Nota: El módulo led 65BEMW solo se instala con resortes de torsión. No se suministran
otros sujetadores de montaje.
Paso 1B: Pinzas de resorte de retención (Módelo 4BEMW LED)
1. Si es necesario, Quitar el lastre y asegurar la potencia de entrada es da 120 V antes
de la instalación.
Nota: El módulo led 4BEMW solo se instala con resortes de retención. No se suministra
otros sujetadores de montaje.
Paso 1C: sujetadores de resorte de retención ajustables (Módelo 43BEMW LED)
1. Si es necesario, Quitar el lastre y asegurar la potencia de entrada es da 120 V antes
de la instalación.
2. Si es necesario ajustar para adaptarse a diferentes cajas empotradas (puede adaptarse
a cualquier caja de 3 in a 4 in), afl oje (2) tornillos de los sujetadores de resorte de
retención en la parte superior del módulo (Figura 1) y ajuste el sujetador para que se
adapte y se alinee a cualquier carcasa empotrada de 3 in a 4 in.
3. Asegure los tornillos de montaje de los sujetadores de resorte de retención.
Nota: El módulo led 43BEMW solo se instala con sujetadores de resorte de retención.
No se suministran otros sujetadores de montaje.
Paso 2: Cable conectado a tierra
NOTA: EL MÓDULO NO DEBE COLGAR SIN EL APOYO DEL CONECTOR
NARANJA (Figura 2).
A. Caja empotrada con cable conectado a tierra:
1. Corte el ojal del cable conectado a tierra del módulo led.
2. Forme pares con el cable conectado a tierra de cobre pelado del módulo led
con el cable conectado a tierra de la caja empotrada y asegure con una tuerca
para cables.
B. Caja empotrada sin cable conectado a tierra:
1. Instale el ojal del cable conectado a tierra en un tornillo de 8-18 x 3/8 in (cajas
Lithonia Lighting).
2. O instale el ojal a través de un tornillo autorroscante de 8-18 o equivalente y
asegure en la pared de la caja.
Paso 3: Determine el método de cableado (seleccione un método de cableado)
A. Adaptador de enchufe E26:
1. Enrosque el adaptador de enchufe E26 en el portalámparas de base dentro de
la caja.
2. Enchufe el conector naranja del adaptador de enchufe E26 en el conector
naranja de acople del módulo led (consultar la Figura 3). O,
B. Adaptador GU10:
1. adaptador GU10 de giro en el portalámparas de base dentro de la caja.
2. Enchufe el conector naranja del adaptador de enchufe GU10 en el conector
naranja de acople del módulo led (consultar la Figura 3). O,
C. Conector led:
1. Enchufe el conector naranja del módulo en el conector naranja de acople en
la caja empotrada. -Este tipo de conexión cumple con el Título 24 (instalación
permanente de led).
Nota: El módulo no incluye juego de conexión de cableado.
Paso 4: Instalación del módulo en la caja empotrada
A. Resortes de torsión (Modelo 65BEMW LED): Comprima cada resorte de torsión
junto y asiéntelos dentro de los soportes de torsión de la caja. Libere los resortes y
empuje suavemente el módulo en la caja que quede a nivel del techo (Figura 4).
B. Sujetadores de retención de resorte (Módelo 4BEMW LED & 43BEMW LED): Centre
el módulo led en la abertura de la caja y empuje suavemente el módulo hacia arriba
en la caja de manera uniforme sobre todos los lados hasta que quede nivelado con
el techo (Figura 5).
NOTA:
• Alinee los dos sujetadores de retención con la caja empotrada, evitando obstruir
con algún objeto que sobresalga en las paredes de la caja.
• Para retirar un módulo led empotrado con sujetadores de retención, tire
hacia abajo y gire hacia adelante y hacia atrás hasta que se libere. Utilice dos
destornilladores planos estándares para extraer el módulo de la caja empotrada.
Esto será de ayuda para el proceso de retiro.
___________________________________________________________
REDUCTORES DE INTENSIDAD DE LUZ RECOMENDADOS: Los módulos led
son compatibles con varios reductores de alumbrado estándares de uso residencial.
Puede encontrar una lista de reductores de alumbrado recomendados en
www.lithonia.com e ingrese la palabra clave de búsqueda 65BEMW, 4BEMW, o
43BEMW. Si no se encuentran en la lista, esto no signifi ca que un reductor de
alumbrado no funcionará con su módulo led. Consulte al fabricante del reductor de
alumbrado sobre la compatibilidad con los módulos/lámparas led.
COMPATIBILIDAD DE LA CARCASA EMPOTRADA: Los módulos led de 65BEMW
de Lithonia son sometidos a prueba para adaptarse a una caja de mínimo 5 in de
diámetro por 7 in de altura, con un diámetro de base máximo de 7.5 in. Los módulos
led de 4BEMW de Lithonia son sometidos a prueba para adaptarse a una caja de mínimo
4 in de diámetro por 6 in de altura, con un diámetro de base máximo de 5.25 in. Los
módulos led de 43BEMW de Lithonia son sometidos a prueba para adaptarse a una caja
de mínimo 3 in de diámetro por 4 in de altura, con un diámetro de base máximo de 5.25
in. Para acceder a la lista de cajas compatibles: ingrese a www.lithonialighting.com y
escriba la palabra clave de búsqueda 65BEMW, 4BEMW o 43BEMW.
LISTADOS: CSA certifi cado por los estándares de seguridad canadienses y de EE. UU.;
certifi cación Energy Star; conforme al Título 24 de California; protegido para lugares
húmedos; y WSEC ASTEM E283 para uso hermético clasifi cado para construcciones
con IC (techo con aislamiento). 65BEMW compartimiento de la lámpara mínimo de 5
in (127 mm) de diámetro por 7 in (180 mm) de altura o compartimiento de lámpara
mínimo de 137 in³ (2315 cm³). 4BEMW compartimiento de la lámpara mínimo de 4
in (100 mm) de diámetro por 6 in (150 mm) de altura o compartimiento de lámpara
mínimo de 75.4 in³ (1178 cm³). 43BEMW compartimiento de la lámpara mínimo de 3 in
(76 mm) de diámetro por 4 in (102 mm) de altura o compartimiento de lámpara mínimo
de 28.3 in³ (462 cm³). Use solo en luminarias abiertas. Apropiado para luminarias tipo
ic o tipo sin ic. El juego de readaptación es aceptado como un componente de una
luminaria donde la idoneidad de la combinación debe ser determinada por CSA o las
autoridades que tengan jurisdicción.
PATENTES PENDIENTES
Étape 2 : Fil de mise à la terre
REMARQUE – NE PAS LAISSER LE MODULE PENDRE DANS LE VIDE AVEC
LE CONNECTEUR ORANGE (Schéma 2).
A. Boîtier encastré avec fi l de mise à la terre:
1. Couper l’oeillet du fi l de mise à la terre du module DEL.
2. Coupler le fi l de mise à la terre de cuivre nu du DEL avec le fi l de mise à la terre
du boîtier encastré et fi xer solidement avec un capuchon de connexion.
B. Boîtier encastré sans fi l de mise à la terre:
1. Installer l’oeillet du fi l de mise à la terre dans une vis de 8-1/8 x 3/8 po (boîtiers
d’éclairage Lithonia). ou,
2. Installer l’oeillet à travers une vis autotaraudeuse de 8-1/8 ou l’équivalent et le
xer à la paroi du boîtier.
Étape 3 : Déterminer la méthode de câblage (Sélectionner une méthode de câblage)
A. E26 Adaptateur de douille:
1. Visser l’adaptateur de douille E26 dans la douille de la base à l’intérieur du
boîtier.
2. Brancher le connecteur orange de l’adaptateur de douille E26 dans le connecteur
orange compatible du module DEL (Schéma 3). ou,
B. GU10 Adaptateur:
1. tourner la douille GU10 dans la douille de la base à l’intérieur du boîtier.
2. Brancher le connecteur orange de l’adaptateur GU10 dans le connecteur orange
compatible du module DEL (Schéma 3). ou,
C. Connecteur LED:
1. Brancher le connecteur orange du module dans le connecteur orange
compatible du boîtier encastré. -Ce type de connexion est conforme avec
l’appellation 24 (installation permanente de LED).
Remarque: Aucun kit de connexion de câblage fi xe n’est fourni avec le module.
Étape 4 : Installation du module dans le boîtier encastré
A. Ressorts de torsion (Modèle 65BEMW LED): Pincer ensemble chaque ressort de
torsion et les loger à l’intérieur des supports de torsion du boîtier. Relâcher les
ressorts et pousser délicatement le module dans le boîtier jusqu’à ce qu’il affl eure
le plafond (Schéma4).
B. Pinces de retenue de ressort (Módelo 4BEMW LED & 43BEMW LED): CCentrer le
module DEL dans l’ouverture du boîtier et pousser délicatement le module dans le
boîtier uniformément sur tous les côtés jusqu’à ce qu’il affl eure le plafond (Schéma
5).
REMARQUE:
• Aligner les deux pinces de retenue avec le boîtier encastré en évitant les
interférences avec tout ce qui dépasse des parois du boîtier.
• Pour le retrait d’un module DEL encastré avec des pinces de retenue, tirer sur le
module et le faire pivoter de l’avant vers l’arrière jusqu’à ce qu’il sorte. Utiliser
deux tournevis plat pour extraire le module en dehors du boîtier encastré. Ceci
aidera dans le processus de retrait.
_____________________________________________________________
GRADATEURS RECOMMANDÉS: Les modules DEL sont compatibles avec
une multitude de gradateurs résidentiels. Vous trouverez une liste de gradateurs
recommandés sur www.lithonia.com, mot-clé de recherche : 65BEMW, 4BEMW,
ou 43BEMW. Un gradateur non présent dans la liste ne signifi e pas que celui-ci
ne fonctionne pas avec votre module DEL. Consulter votre fabricant de gradateur
concernant la compatibilité avec les modules/lampes DEL.
COMPATIBILITÉ DU BOÎTIER ENCASTRÉ: Les modules DEL de 65BEMW de
Lithonia sont testés pour s’ajuster dans une ouverture minimale de 5 po de diamètre
x 7 po de hauteur, avec un diamètre de rebord maximal de 7,5 po. Les modules DEL
de 4BEMW de Lithonia sont testés pour s’ajuster dans une ouverture minimale de 4
po de diamètre x 6 po de hauteur, avec un diamètre de rebord maximal de 5,25 po.Les
modules DEL de 43BEMW de Lithonia sont testés pour s’ajuster dans une ouverture
minimale de 3 po de diamètre x 4 po de hauteur, avec un diamètre de rebord maximal de
5,25 po. Pour obtenir la liste des boîtiers compatibles, aller à www.lithonialighting.com,
mot-clé de recherche : 65BEMW, 4BEMW ou 43BEMW.
HOMOLOGATION: Certifi é CSA pour les normes de sécurité aux États-Unis et
au Canada; qualifi é Energy Star; conforme aux exigences de la Californie, titre 24;
répertorié pour emplacements humides; et WSEC ASTEM E283 comme étanche à l’air
avec les boîtiers de type CI. 65BEMW taille minimum du compartiment de la lampe :
127 mm (5 po) de diamètre par 180 mm (7 po) de hauteur ou un volume minimum de
2315 cm³ (137 in³). 4BEMW taille minimum du compartiment de la lampe : 100 mm
(4 po) de diamètre par 150 mm (6 po) de hauteur ou un volume minimum de 1178cm³
(75.4 in³). Àutiliser uniquement avec les luminaires ouverts. 43BEMW taille minimum
du compartiment de la lampe : 76 mm (3 po) de diamètre par 102 mm (4 po) de hauteur
ou un volume minimum de 462cm³ (28.3 in³). Àutiliser uniquement avec les luminaires
ouverts. Compatible avec les luminaires de types « CI » et « non CI ». Le nécessaire
de modifi cations est considéré comme un composant d’un luminaire pourvu que la
pertinence de la combinaison soit confi rmée par la CSA ou les autorités compétentes.
EN ATTENTE DE BREVET
INSTRUCTIONS D’INSTALLATION - 65BEMW LED, 4BEMW LED, &
43BEMW LED
(Module DEL avec déflecteur de 15,24 cm, 12,7 cm, 10,16 cm, & 7,62 cm)
Apte pour les endroits humides.
Cet appareil n’est pas conçu pour une utilisation avec les issues de
secours ou pas pur eclairage.
ATTENTION - choc et d’incendie, ne pas utiliser une enceinte est cassé.
AVERTISSEMENT - risque d’incendie ou d’électrocution. Câblage de
luminaires, d’alimentation ou d’autres pièces électriques peuvent être
endommagés lors du perçage pour l’installation du matériel de rénovation
de l’Assemblée. Inspecter le câblage et composants pour les dommages.
ADVERTISSEMENT - risque d’incendie ou de choc électrique. Installation
de ce montage de rattrapage exige une personne familière avec la
contruction et exploitation du système électrique luminaire et de la
risques liés. Ne qualifi e pas, ne pas essayer d’installation. Contactez un
électricien qualifi é.
ADVERTISSEMENT - risque d’incendie ou de choc électrique. Installer ce
kit seulement dans les luminaires qui a le caractéristiques de dimensions
le montrent les photographies et / ou dessins.
Ne pas faire ou modifi er des trous de chasse dans une enceinte de cablage
ou de composants électriques pendant kit installation.
ADVERTISSEMENT - pour éviter d’endommager câblage ou à l’abrasion, ne
pas exposer le câblage à bords de tole ou autres objets tranchants.
Let kit de rattrapage est acceptée comme une composante d’un luminaire
où la pertinence de la combinasion sera déterminée par la csa ou autorités
ayant jurisdiction.
6”et 5” Matte White Baffl e module LED, Modèle 65BEMW LED 27K M6,
65BEMW LED 30K M6 et 65BEMW LED 40K M6, 120V d’entrée 60Hz,
0.10A, 12W.
4” Matte White Baffl e module LED, Modèle 4BEMW LED 27K M6, 4BEMW
LED 30K M6 y 4BEMW LED 40K M6, 120V d’entrée 60Hz, 0.09A, 10W.
3” Matte White Baffl e module LED, Modèle 43BEMW LED 27K M6,43BEMW
LED 30K M6 y 43BEMW LED 40K M6 120V d’entrée 60Hz, 0.09A, 10W.
Chaque boite unitaire contient module de 1ea LED, 1ea E26 adapteur,
1ea GU10 adapteur (43BEMW seulement), connecteur 1ea et 1ea
remplacement Etiquette (apposée sur le luminaire modernisé).
Outils nécessaires (non inclus): lunettes de sécurité et des gants.
Étape 1A: Supports de ressort de torsion (Modèle 65BEMW LED)
1. Si nécessaire, retirer le ballast et d’assururer la puissance d’entrée est de 120 V
avant l’installation.
2. Desserrer les vis de fi xation (2) du support de torsion sur le dessus du module
(Schéma 1) pour régler les supports et les ressorts de torsion afi n qu’ils s’adaptent
et s’alignent avec les pinces de supports du boîtier encastré de 5 ou 6 po.
3. Serrer fermement les vis de fi xation du support de torsion.
Remarque: Le module DEL 65BEMW s’installe uniquement avec les ressorts de
torsion, aucunes autres pinces de fi xation ne sont fournies.
Étape 1B: Pinces de ressort de retenue (Modèle 4BEMW LED)
1. Si nécessaire, retirer le ballast et d’assururer la puissance d’entrée est de 120 V
avant l’installation.
Remarque: Le module DEL 4BEMW s’installe uniquement avec les ressorts de
retenue, aucunes autres pinces de fi xation ne sont fournies.
Étape 1C: et clip de retenue réglable (Modèle 43BEMW LED)
1. Si nécessaire, retirer le ballast et d’assururer la puissance d’entrée est de 120 V
avant l’installation.
2. S’il est nécessaire d’adapter l’appareil à différents boîtiers d’encastrement [il
s’adapte à ceux de 7,62 à 10,15 cm (3 à 4 po)], desserrez les deux vis du clip à
ressort de retenue situées au-dessus du module (Schéma 1) et réglez le clip pour
l’adapter et l’aligner avec l’un des boîtiers de 7,62 à 10,15 cm (3 à 4 po).
3. Serrez fermement les vis de montage des clips à ressort de retenue.
Remarque: Le module DEL 43BEMW s’installe uniquement avec clip de retenue
réglable, aucunes autres pinces de fi xation ne sont fournies.
Figure 4 / Figura 4 / Schéma 4
Figure 3 / Figura 3 / Schéma 3
Socket adapter or GU10 adapter
/ Adaptador de enchufe o Adaptador GU10
/ Adaptateur de douille ou Adaptateur GU10
Orange connector
/ Conector naranja
/ Connecteur orange
Figure 2 / Figura 2 / Schéma 2
Eyelet
/ Ojal
/ OEillet
Recess can torsion brackets &
adjustable retention clip
/ Carcasa empotrada, soportes
de torsión y sujetador de
retención ajustables
/ Supports de torsion et clip de
retenue réglable du boîtier
E-SERIES LED RETROFIT DOWNLIGHT INSTALLATION INSTRUCTIONS
43BEMW LED
43BEMW LED
43BEMW LED
43BEMW LED
43BEMW LED
43BEMW LED
For 65BEMW loosen torsion bracket mounting screws to adjust for 6” or 5” recess housing. For 43BEMW loosen
adjustable retention spring clips and adjust for any of 4” to 3” recess housing.
/ Para 65BEMW, a oje los tornillos de montaje del soporte de torsión para ajustarlo a cajas empotradas de 6 in o 5
in. - Para 43BEMW,a oje los sujetadores de resorte de retención ajustables para ajustarlo a cajas empotradas de 4
in o 3 in, si es necesario.
/ Pour le 65BEMW, desserrez les vis de montage du ressort de torsion pour l’adapter au boîtier d’encastrement de
15,24 ou de 12,7 cm (6 ou 5 po). Pour le 43BEMW, desserrez les clips du ressort de retenue réglable et réglez-les
pour le boîtier d’encastrement de 10,16 ou de 7,62 cm (4 ou 3 po) si nécessaire.
Figure 1 / Figura 1 / Schéma 1
Page 3 of 4
4BEMW LED 4BEMW LED4BEMW LED
65BEMW LED 65BEMW LED
65BEMW LED 3.5” can size mounting reference for
43BEMW
/ 3.5” puede ser el tamaño de referencia
de montaje para 43BEMW
/ La taille de référence de montage pour
43BEMW peut être de 3,5 po
DISCONTINUED
  • Page 1 1
  • Page 2 2

Lithonia Lighting 3" and 4" E Series LED Module Guide d'installation

Taper
Guide d'installation