NOTICE: This service data sheet is intended for use by persons having electrical
and mechanical training and a level of knowledge of these subjects generally
considered acceptable in the appliance repair trade. The manufacturer cannot
be responsible, nor assume any liability, for injury or damage of any kind arising
from the use of this data sheet.
IMPORTANT NOTE: This unit includes an EOC (electronic oven control). This
board is not eld-repairable.
Safe Servicing Practices
To avoid the possibility of personal injury and/or property damage, it is important
that safe servicing practices be observed. The following are some, but not all,
examples of safe practices.
1. Do not attempt a product repair if you have any doubts as to your ability to
complete it in a safe and satisfactory manner.
2. Before servicing or moving an appliance, remove power cord from electric
outlet, trip circuit breaker to Off, or remove fuse.
3. Never interfere with the proper installation of any safety device.
4. Use only replacement parts specied for this appliance. Substitutions may
not comply with safety standards set for home appliances.
5. Grounding: The standard color coding for safety ground wires is green
or green with yellow stripes. Ground leads are not to be used as current
carrying conductors. It is extremely important that the service technician
reestablish all safety grounds prior to completion of service. Failure to do so
will create a potential hazard.
6. Prior to returning the product to service, ensure that:
All electric connections are correct and secure.
All electrical leads are properly dressed and secured away from sharp
edges, high-temperature components, and moving parts.
All uninsulated electrical terminals, connectors, heaters, etc. are ade-
quately spaced away from all metal parts and panels.
All safety grounds (both internal and external) are correctly and secure-
ly reassembled.
All panels are properly and securely reassembled.
IMPORTANT
DO NOT REMOVE THIS BAG
OR DESTROY THE CONTENTS
WIRING DIAGRAMS AND SERVICE
INFORMATION ENCLOSED
REPLACE CONTENTS IN BAG
A13273201 REV B (2018/12)
SERVICE DATA SHEET - Microwave Combination Unit with Modular Electronic Oven Control
GROUNDING INSTRUCTIONS
This oven is equipped with a three prong grounding plug. It must be plugged into
the wall oven receptacle that is properly installed and grounded in accordance
with the National Electrical Code and local codes and ordinances.
In the event of an electrical short circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric current.
WARNING: Improper use of the
grounding plug can result in a risk of
electric shock.
Electrical Requirements
The electrical requirements are a 120
volt 60 Hz, AC only, a branch circuit
protection fuse, 20 amp is provided in
series with the ac outlet on top of the
wall oven support.
*Note: Branch circuit fuse 20 amp
shall be replaced with class cc type.
DOOR SENSING AND PRIMARY INTERLOCK SWITCHES
The primary interlock switch is mounted in the lower position of the latch hook and
the door sensing switch in the secondary interlock system is mounted in the upper
position of the latch hook. They are activated by the latch heads on the door. When
the door is opened, the switches interrupt the power to all high voltage components.
A cook cycle cannot take place until the door is rmly closed thereby activating both
interlock switches. The secondary interlock system consists of the door sensing
switch and secondary interlock relay located on the control circuit board.
MONITOR SWITCH
The monitor switch is activated (the contacts opened) by the latch head on the door
while the door is closed. The switch is intended to render the oven inoperative, by
means of blowing the monitor fuse, when the contacts of the secondary interlock
relay (RY2) and primary interlock switch fail to open when the door is opened.
Functions:
1. When the door is opened, the monitor switch contact close (to the ON condition)
due to their being normally closed. At this time the secondary interlock relay
(RY2) and primary interlock switch are in the OFF condition (contacts open)
due to their being normally open contact switches.
2. As the door goes to a closed position, the monitor switch contacts are rst opened
and then the door sensing switch and the primary interlock switch contacts close.
(On opening the door, each of these switches operate inversely.)
3. If the door is opened, and the secondary interlock relay (RY2) and primary
interlock switch contacts fail to open, the monitor fuse blows simultaneously
with closing of the monitor switch contacts.
CAUTION: BEFORE REPLACING A BLOWN MONITOR FUSE TEST THE
DOOR SENSING SWITCH, SECONDARY INTERLOCK RELAY (RY2), RELAY
(RY1), PRIMARY INTERLOCK SWITCH AND MONITOR SWITCH FOR PROP-
ER OPERATION. (REFER TO CHAPTER «TEST PROCEDURE»).
NOTE: MONITOR FUSE AND MONITOR SWITCH ARE REPLACED AS AN
ASSEMBLY.
CAVITY TEMPERATURE FUSE
The cavity temperature fuse located on the top of the oven cavity, is designed to
prevent damage to the oven by re. If the food load is overcooked, by either error
in cook time or defect in the control unit, the cavity temperature fuse will open.
Under normal operation, the cavity temperature fuse remains closed. However, when
abnormally high temperatures are reached within the oven cavity, the cavity temperature
fuse will open at 302
O
F(150
O
C) causing the oven to shut down.
NOTE: This is fuse. It does not reset.
MONITOR FUSE
1. The monitor fuse blows when the contacts (COM-NO) of the primary interlock
relay (RY2) and secondary interlock switch remain closed with the oven door
open and when the monitor switch closes.
2. If the wire harness or electrical components are short-circuited, this monitor
fuse blows to prevent an electric shock or re hazard.
MAGNETRON TEMPERATURE FUSE
The magnetron temperature fuse located near the magnetron is designed to prevent
damage to the magnetron if an over heated condition develops in the tube due to
cooling fan failure, obstructed air guide, dirty or blocked air intake, etc.
Under normal operation, the magnetron temperature fuse remains closed. However,
when abnormally high temperatures are reached within the magnetron, the magne-
tron temperature fuse will open at 302°F(150°C) causing the oven to shut down.
NOTE: This is a fuse. It does not reset.
AVIS: Cette feuille de données d’entretien est destinée aux personnes ayant reçu une
formation en électricité et en mécanique, et qui possèdent un niveau de connaissance
jugé acceptable dans l’industrie de réparation des appareils électroménagers. Le
fabricant ne peut être tenu responsable, ni assumer aucune responsabilité, pour toute
blessure ou dommage de quelque nature que ce soit pouvant résulter de l’utilisation de
cette feuille de données.
NOTES IMPORTANTES: Cet appareil inclut un contrôleur de four électronique. Le
tableau de contrôle n’est pas réparable sur place.
Pratiques d’entretien Sécuritaires
Pour éviter tout risque de blessure et/ou dommage matériel, il est important que des
pratiques d’entretien sécuritaires soient suivies. Voici quelques exemples de pratiques
sécuritaires.
1. N’essayez jamais de réparer un appareil si vous ne croyez pas avoir les com-
pétences nécessaires pour le faire de manière satisfaisante et sécuritaire.
2. Avant de procéder au service d’entretien ou de déplacer tout appareil ménager,
débranchez le cordon d’alimentation de la prise électrique, réglez le disjoncteur
de circuit à OFF, ou enlevez le fusible et fermez le robinet d’alimentation en gaz.
3. N’entravez jamais l’installation adéquate de tout dispositif de sécurité.
4. Utilisez que les pièces de remplacement énumérées dans le catalogue pour cet
appareil. La moindre substitution risque de ne pas être conforme aux normes de
sécurité établies pour les appareils électroménagers.
5. Mise à la Terre: La couleur de codage standard des conducteurs de mise à la
terre de sécurité est verte ou verte à barres jaunes. Les conducteurs de mise à
la terre ne doivent pas être utilisés comme conducteurs de courant. Il est d’une
importance capitale que le technicien d’entretien complète toutes les mises à la
terre de sécurité avant de terminer le service. Si cette recommandation n’est pas
suivie à la lettre, il en résultera des risques pour les personnes et les biens.
6. Avant de retourner le produit au service de réparation ou d’entretien, as-
surez-vous que:
Toutes les connexions électriques sont correctes et sécuritaires.
Tous les conducteurs électriques sont correctement préparés et à l’abri des
bords tranchants, des composants à température élevée, et des parties
mobiles.
Toutes les bornes électriques, connecteurs, réchauffeurs, etc. dénudés sont
espacés convenablement loin de toute pièce en métal et des panneaux.
Toutes les mises à la terre de sécurité (interne et externe) sont correcte-
ment ré-assemblées de façon sécuritaire.
Tous les panneaux sont correctement et fermement remontés.
INSTRUCTIONS DE MISE À LA TERRE
Cet appareil est muni d’une che
d’alimentation électrique à trois ls mise à
la terre. Elle doit être branchée à la prise
de courant qui est correctement installée et
mise à la terre conformément au National
Electrical code et aux codes locaux et
règlements, située sur le dessus du four.
Dans l’éventualité d’un court-circuit, la mise à
la terre réduit le risque de choc électrique en
permettant au courant électrique de passer
par le l de mise à la terre.
AVERTISSEMENT: Une mauvaise utilisation
du l de mise à la terre peut résulter en un
choc électrique.
Requis électriques
Les requis électriques sont: 120 volt 60 Hz, AC seulement, un fusible de protection du
circuit, 20 ampères est fourni en série avec la prise AC sur la dessus du four.
*Note: Le fusible du circuit terminal de 20 ampères doit être remplacé par un de type
classe cc.
IMPORTANT
N’ENLEVEZ P
AS CE SAC OU NE
DÉTR
UISEZ P
AS SON CONTENU
CONTIENT LES SCHÉMAS DE CÂBLAGE ET
LES INFORMATIONS DE RÉPARATION
REMETTRE LE CONTENU
DANS LE SAC
FEUILLET DE DONEÉS TECHNIQUES - Électroménager avec commande de four électronique ES530/535.
INTERRUPTEUR SENSIBLE ET INTERRUPTEUR DE VERROUILLAGE PRIMAIRE
L’interrupteur de verrouillage primaire est monté à la position la plus basse du support
de taquet et interrupteur sensible de la porte du système d’interrupteur secondaire
est monté à la position la plus haute du support de taquet. Ils sont activé par les têtes
du taquet sur la porte. Lorsque la porte est ouverte, les interrupteurs interrompent
le courant à toutes les composantes à haut voltage. Un cycle de cuisson ne peut
pas fonctionner tant que la porte n’est pas complètement fermée, ce qui activent les
interrupteur de verrouillage. Le système d’interrupteur de verrouillage secondaire
consiste en un interrupteur sensible et un relais de verrouillage secondaire situés sur
la plaque de série.
L’INTERRUPTEUR DE CONTRÔLE
L’interrupteur de contrôle est activé (les contacts sont ouverts) par la tête du taquet
sur la porte lorsqu’elle est fermée. L’interrupteur est destiné à rendre le four inactif,
en faisant sauter le fusible de contrôle, lorsque le contact du relais du verrouillage
secondaire (RY2) et l’interrupteur de verrouillage primaire échouent l’ouverture lorsque
la porte est ouverte.
Fonctions:
1. Lorsque la porte est ouverte, le contact de l’interrupteur de contrôle est fermé
(condition ON) puisque normalement il est fermé. À ce moment, le relais verrouillage
secondaire (RY2) et l’interrupteur verrouillage primaire sont en position OFF
(contacts ouverts) puisque normalement, les contacts des interrupteurs sont ouverts.
2. Lorsque la porte passe en position fermée, le contact de l’interrupteur de contrôle
est le premier ouvert et ensuite les contacts de l’interrupteur sensible de la porte
et de l’interrupteur de contrôle primaire sont fermés (sur une porte ouverte,
chacun de ces interrupteurs fonctionne de façon inversée.
3. Si la porte est ouverte, et que les contacts du relais verrouillage secondaire
(RY2) et de l’interrupteur de contrôle primaire échouent à l’ouverture, le fusible
de contrôle saute et en même temps, le contact de l’interrupteur de contrôle se
ferme.
ATTENTION: Avant de remplacer un fusible de contrôle brûlé, vériez Si l’interrupteur
sensible de la porte, le relais verrouillage secondaire (RY2), le relais (RY1), l’inter-
rupteur verrouillage primaire et l’interrupteur de contrôle fonctionnent correctement.
(Référez-vous à la section «procédure de TEST»).
NOTE: Le fusible de contrôle et l’interrupteur contrôle peuvent être remplacé en-
semble.
FUSIBLE DE LA TEMPÉRATURE DE LA CAVITÉ
Le fusible de la température de la cavité, situé sur le dessus de la cavité du four, est désigné
pour prévenir les dommages pouvant être causé au four par un feu. Si la nourriture est
cuite outre mesure, par soit une erreur de temps de cuisson ou par un défaut du contrôle
du four, le fusible de température de la cavité s’ouvrira.
Lorsque le four est utilisé normalement, le fusible de la température de la cavité demeure
fermé. Toutefois, lorsque des températures anormales sont atteintes dans la cavité du
four, le fusible sautera à 302
O
F (150
O
C) causant ainsi l’arrêt du four.
NOTE: C’est un fusible. Il ne peut pas être réinitialisé.
FUSIBLE DE CONTRÔLE
1. Le fusible de contrôle saute lorsque les contacts (COM-NO) du relais de
verrouillage primaire (RY2) et l’interrupteur de verrouillage secondaire restent
fermés avec la porte ouverte et lorsque l’interrupteur de contrôle est fermé.
2. Si le faisceau électrique et les composantes électriques sont en court-circuit, le
fusible de contrôle saute pour prévenir un choc électrique ou un incendie.
FUSIBLE DE LA TEMPÉRATURE DU MAGNÉTRON
Le fusible de la température du magnétron est situé près du magnétron et est désigné
pour prévenir les dommages possibles au magnétron si une condition de surchauffage
se développe dans le tube dû à une défaillance du ventilateur de refroidissement, à une
obstruction de la conduite de l’air, à un blocage de l’évent, etc.
En condition normale, le fusible de la température de magnétron reste fermé.
Toutefois, lorsque des températures anormales sont atteintes dans le magnétron, le
fusible sautera à 302°F (150°C) causant ainsi l’arrêt du four.
NOTE: C’est un fusible. Il ne peut pas être réinitialisé.
ELECTRONIC OVEN CONTROL (EOC) FAULT CODE DESCRIPTIONS
Fault
Code
Description of Error Code Suggested Corrective Action
F01 F02
F04 F05
Touch panel failure Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the touch panel.
F03 The oven user interface board is incorrectly
congured.
Replace the oven user interface board. Make sure you install the latest revision available for this model.
F10 Oven temperature runaway: the cavity tem-
perature has been detected in excess of the
maximum safe operating temperature.
1. If oven is overheating, disconnect power. Check oven temperature probe (RTD) and replace if necessary.
2. If the oven temperature probe is good and if oven continues to overheat when power is reapplied, replace the oven relay board.
F11 Stuck key: a key has been detected has pressed
continuously for 30 seconds or more.
1. If a key was pressed inadvertently for a long time this error code will be displayed. Make sure there is nothing (water, utensils) in contact with
the keyboard. The fault code should go away once the key is released and the Stop key is pressed. If the F011 error comes back when a key is
pressed it means the error condition is still there. If the F011 error does not come back it means the error condition is gone and the oven can be
used.
2. If the fault code cannot be cleared, test the wiring harness between oven user interface board (connector I2C1 or I2C2) and touch panel (connec-
tor I2C1 or I2C2).
3. If the fault code cannot be cleared and the wiring is good, the touch panel is most likely defective: replace the touch panel.
4. If changing the touch panel did not x the problem replace the oven user interface board.
F12 Keyboard conguration alarm: the oven user
interface board received from the touch panel a
key code that does not match the key map.
1. Verify the unit has the proper oven user interface board and touch panel, based on the model number and parts catalog.
2. Replace the oven user interface board.
3. If the problem persists replace the touch panel.
F13 Data written to non-volatile memory has failed
verication
Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the oven user interface.
F15 Keyboard error Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the touch panel.
F17 The oven user interface board is unable to
congure the touch panel.
1. Disconnect power to the unit, wait 30 seconds, then reapply power.
2. If fault returns, verify harness going to I2C1 or I2C2 connector of the touch panel.
3. Verify the unit has the proper oven user interface board and touch panel, based on the model number and parts catalog.
4. If fault persists, replace the oven user interface.
5. If fault persists, replace the touch panel.
F18 Oven relay board failure (wiggler) Replace the oven relay board.
F19 The oven user interface board is unable to
congure the oven relay board
1. Disconnect power to the unit, wait 30 seconds, then reapply power.
2. If fault returns, verify connection between the oven user interface board (MACS1 or MACS2 connector) and the oven relay board (connector J3
or J4).
3. Verify the unit has the proper oven user interface board and oven relay board, based on the model number and parts catalog.
4. If fault persists, replace oven user interface board.
5. If fault persists, replace the relay board.
F22 Communication failure between the oven user
interface board and the oven relay board
1. Disconnect power, wait 30 seconds and reapply power. Check if error condition is still there.
2. Test wiring harness between oven user interface board (connector MACS1 or MACS2) and oven relay board (connector J3 or J4).
3. If wiring harness is good replace oven relay board.
4. If the problem persists replace the oven user interface.
F23 Communication failure between the oven user
interface board and the glass touch panel
1. Disconnect power, wait 30 seconds and reapply power. Check if error condition is still there.
2. Test wiring harness between oven user interface board (connector I2C1 or I2C2) and touch panel (connector I2C1 or I2C2).
3. If wiring harness is good replace touch panel.
4. If the problem persists replace the oven user interface.
F25
F27
The communication between the over user
interface and the oven relay board cannot be
initiated.
1. Disconnect power to the unit, wait 30 seconds, then reapply power.
2. If fault returns, verify connection between the oven user interface board (MACS1 or MACS2 connector) and the oven relay board (connector J3
or J4).
3. Verify the unit has the proper oven user interface board and oven relay board, based on the model number and parts catalog.
4. If fault persists, replace relay board.
5. If fault persists, replace the oven user interface board.
F28
F29
The communication between the over user inter-
face and the touch panel cannot be initiated.
1. Disconnect power to the unit, wait 30 seconds, then reapply power.
2. If fault returns, verify touch panel is connected (verify harness going to I2C1 or I2C2 connector) and is getting power from the oven user interface.
3. Verify the unit has the proper oven user interface board and touch panel, based on the model number and parts catalog.
4. If fault persists, replace the touch panel.
5. If fault persists, replace the oven user interface.
F30 Open oven temperature sensor (RTD) 1. Check probe circuit wiring for possible open or short condition.
2. Verify RTD resistance at room temperature (compare to probe resistance chart). If resistance does not match the chart, replace the RTD probe.
3. If the problem persists replace the oven relay board.
F31 Shorted oven temperature probe (RTD)
F33 Meat probe temperature sensor shorted or too
hot
1. The error is triggered if the meat probe sees a temperature in excess of 392°F. Make sure the meat probe was not used in such way that it could
have seen such temperature. If the tip of the probe is not inserted in the meat it will see the cavity temperature, which can be higher than 392°F
(depending on the setpoint) and trigger the alarm.
2. When the meat probe is connected to the socket inside the oven cavity, if the meat probe is not fully inserted into the socket it may short the
contacts and cause the error. Make sure the probe is inserted as much as it can.
3. Verify meat probe resistance at room temperature. Compare to meat probe resistance chart. If the meat probe does not match the chart, replace
it.
4. If the above steps failed to correct the problem, replace the oven relay board.
F45 Cooling fan speed too low. 1. Check if the cooling fan blades are blocked.
2. Conrm tachometer harness is connected on fan and on oven control.
3. Replace cooling fan.
4. Replace oven control.
F46 Cooling fan speed too high. 1. Check for mechanical obstruction in the air path.
2. Replace cooling fan.
3. Replace oven control.
F50 A/D Out of Range: the oven relay board is unable
to read the status of the switches (door, MDL)
1. Check to ensure that the connections between the door switch, MDL and temp probes are properly connected. This includes all splices and
junctions.
2. If the above step failed to correct the problem, replace the oven relay board.
F90 Motor Door Lock mechanism failure. The oven
control does not see the Motor Door Lock
running.
1. Disconnect power to the unit, wait 30 seconds, then reapply power. Try again to make the door lock or unlock (ex: initiate a Lockout or a Clean
cycle).
2. Check if the Lock Motor is running or not. If it is not running, test the wiring between the Lock Motor and the oven relay board. If the wiring is
good, check if there is 120VAC at the motor when it is expected to run to see if the failure originates from a bad motor (120VAC present but not
turning) or a problem with the relay board (J20 pin 10 on the oven relay board is the output to the Lock Motor). The Lock Motor can also be test-
ed by applying 120VAC directly to the motor (unplug it from the relay board rst). If the Lock Motor does not run when 120VAC is applied replace
the Lock Motor Assembly. If it is the relay board that does not provide 120VAC to the Lock Motor replace the oven relay board.
3. If the Lock Motor is running but the oven control cannot nd the locked or unlocked position (ex: motor turns continuously until F90 fault code
is generated) the Lock Switch needs to be veried. Check wiring between Lock Switch and oven relay board. Verify with ohmmeter if the switch
makes contact properly (verify continuity with ohmmeter when the switch is pressed). If the Lock Switch is defective replace the Motor Lock
Assembly.
4. If all above steps failed to correct the situation, replace the oven relay board.
F95 Motor Door Lock mechanism failure. The Motor
Door Lock does not stop running or the Lock
Switch sends an invalid signal.
1. The problem can be caused by a faulty Lock Switch or by a defective oven relay board. If the Motor Door Lock is always running (as if the relay
controlling it is stuck closed) replace the oven relay board.
2. If the motor is not always running replace the Motor Lock Assembly.
F96 The oven door has been detected open during a
Self Clean cycle.
1. This error occurs if the door switch has lost its contact during a Self Clean cycle. Make sure the oven door closes well and fully presses on the
door switch plunger when the door is locked, and no one attempted to pull on the oven door during the Self Clean cycle.
2. Test continuity of wiring between the door switch and the oven relay board, make sure the door switch is well connected. With an ohmmeter,
verify the switch is closed when the plunger is pressed. If the door switch is found to be defective replace the door switch.
3. If the switch and wiring are good and the problem persists, replace the oven relay board.
ELECTRONIC OVEN CONTROL (EOC) FAULT CODE DESCRIPTIONS
Fault
Code
Description of Error Code Suggested Corrective Action
CIRCUIT ANALYSIS
MATRIX
Elements
Door Motor
J20-10 (K13)
Light
J20-6 (K9)
Conv. Fan
Low J20-9 (K12)
High J19-3 (K6)
Door
Switch
J5-7, J5-9
DLB L2
out (K1)
Cooling Fan
Low J20-7 (K10)
High J20-8 (K11)
Catalyst
“Air Guard”
J19-2 (K5)
Bake
P7 (K3)
Broil
K2
Conv.
P8 (K6)
Bake X X X X X X X
Broil X X X
Conv. Bake X X X X X X X
Conv. Roast X X X X X X X
Clean X X X X X X
Locking X
Locked
Unlocking X
Unlocked
Light X
Door Open X X
Door Closed
Air Guard
(with key press)
X X X
X
NOTES: Bake, broil, and convection elements alternate cycles. Convection fans may run during preheat and may run intermittently during non-convection functions to improve cooking performance.
Modular Control Systems
This appliance is equipped with a modular system of controls. The modular
system consists of various boards which communicate with one another to drive
cooking functions. Oven functions, if available, operate through an oven user
interface (UI or UIB) and an oven relay board. Cooktop functions, if available,
operate through a cooktop UI/UIB and a cooktop relay board. There may be addi-
tional boards which work within the system to drive specic functions (refer to the
schematics and diagrams and this sheet). Low voltage operating and communica-
tions power for the modular boards is provided through the wiring schemes. The
boards that generate low voltage operating and communications power depend
upon the individual control system (refer to the schematics and diagrams on
this sheet). These voltages are only the operational voltages. Do not use these
voltages as conrmation of communication between the boards. Communication
occurs through software programming on each board. This communication is not
detectable by volt ohmmeters. The programming is self-monitored and the UI
displays will show error codes based on detected failures. The individual boards
are not eld repairable. See the schematics and diagrams included on this sheet
for more unit-specic details.
OVEN CONTROL
RELAY BOARD
(OVC)
TOUCH PANEL
(BENDER HMI)
OVEN CONTROL
(MARS)
MACS
I2C
Resistance (ohms)
1000 ± 4.0
1091 ± 5.3
1453 ± 8.9
1654 ± 10.8
1852 ± 13.5
2047 ± 15.8
2237 ± 18.5
2697 ± 24.4
Open circuit/infinite resistance
RTD SCALE
Temperature °F (°C)
32 ± 1.9 (0 ± 1.0)
75 ± 2.5 (24 ± 1.3)
250 ± 4.4 (121 ± 2.4)
350 ± 5.4 (177 ± 3.0)
450 ± 6.9 (232 ± 3.8)
550 ± 8.2 (288 ± 4.5)
650 ± 9.6 (343 ± 5.3)
900 ± 13.6 (482 ±7.5)
Probe circuit to case ground
MEAT PROBE TEMPERATURE VS RESISTANCE
Temperature °F (°C) Resistance (Kohm)
77 (25) 50.0 ± 7%
122 (50) 18.0 ± 4.9%
176 (80) 6.3 ± 3.3%
212 (100) 3.4 ± 4.6%
CODES D’ERREUR POUR LA FICHE TECHNIQUE DE LA CUISINIÈRE AVEC BOUTONS DE COMMANDE À L’AVANT
Code Description de l’erreur Actions correctives suggérées
F01 F02
F04 F05
Panneau tactile en échec. Débranchez l’alimentation, attendez 30 secondes et rebranchez. Si le problème réapparaît lorsque l’appareil est rebranché, remplacez le panneau tactile.
F03 La carte interface usager n’est pas cong-
urée correctement.
Remplacez la carte interface usager. Assurez-vous d’installer la dernière version disponible pour ce modèle.
F10 Emballement de la température du four: La
température du four a été détectée comme
étant supérieure à la température maximale
sécuritaire.
1. 1- Si le four surchauffe, débranchez l’alimentation. Vériez la sonde de température (RTD) et remplacez-la si nécessaire.
2. 2- Si la sonde de température est correcte et que le four continue de surchauffer une fois l’appareil rebranché, remplacez le panneau de relais du four.
F11 Touche engagée: Une touche a été
rapportée appuyée pendant 30 secondes
ou plus.
1. Ce code s’afche si une touche est appuyée par inadvertance pendant une longue période. Assurez-vous qu’il n’y a rien en contact avec le panneau
tactile (eau, ustensiles). Le code d’erreur disparaît lorsque la touche est relâchée et que la touche STOP est appuyée. Si le code F011 réapparaît
lorsqu’une touche est appuyée, ceci indique que les conditions de l’erreur sont toujours présentes. Si le code F011 ne réapparaît pas, ceci indique que
les conditions de l’erreur ont disparu et que le four peut être utilisé.
2. Si le code d’erreur ne disparaît pas, vériez le l entre la carte interface usager (connecteur I2C1 ou I2C2) et le panneau tactile (connecteur I2C1 ou
I2C2).
3. Si le code d’erreur ne disparaît pas et que le l est bon, le panneau tactile est probablement défectueux: remplacez le panneau tactile.
4. Si le problème n’est toujours pas réglé après avoir changé le panneau tactile, changez la carte interface usager.
F12 Alarme de conguration de clavier: La carte
interface usager a reçu du panneau tactile
un code qui ne se retrouve pas dans le
registre.
1. À l’aide du numéro de modèle et du catalogue de service, vériez si l’appareil a la bonne carte interface usager et le bon panneau tactile.
2. Remplacez la carte interface usager du four.
3. Si le problème persiste, remplacez le panneau tactile.
F13 Échec lors de la vérication des données
écrites à la mémoire permanente.
Débranchez l’alimentation, attendez 30 secondes et rebranchez. Si le problème réapparaît lorsque l’appareil est rebranché, remplacez la carte interface
usager du four.
F15 Erreur du clavier. Débranchez l’alimentation, attendez 30 secondes et rebranchez. Si le problème réapparaît lorsque l’appareil est rebranché, remplacez le panneau tactile.
F17 La carte interface usager du four est incapa-
ble de congurer le panneau tactile.
1. Débranchez l’alimentation, attendez 30 secondes et rebranchez.
2. Si l’erreur réapparaît, vériez le l allant au connecteur I2C1 ou I2C2 du panneau tactile.
3. À l’aide du numéro de modèle et du catalogue de service, vériez si l’appareil a la bonne carte interface usager et le bon panneau tactile.
4. Si le problème persiste, remplacez la carte interface usager.
5. Si le problème persiste, remplacez le panneau tactile.
F18 Échec du panneau de relais du four
(onduleur)
Remplacez le panneau de relais du four.
F19 La carte interface usager du four est
incapable de congurer le panneau de
relais du four.
1. Débranchez l’alimentation, attendez 30 secondes et rebranchez.
2. Si l’erreur réapparaît, vériez le connexion entre la carte interface usager du four (connecteur MACS1 ou MACS2) et le panneau de relais du four
(connecteur J3 ou J4).
3. À l’aide du numéro de modèle et du catalogue de service, vériez si l’appareil a la bonne carte interface usager et le bon panneau de relais du four.
4. Si le problème persiste, remplacez la carte interface usager.
5. Si le problème persiste, remplacez le panneau de relais du four.
F22 Échec de communication entre la carte
d’interface usager et le panneau de relais
du four.
1. Débranchez l’alimentation, attendez 30 secondes et rebranchez. Vériez si l’erreur est encore présente.
2. Vériez le faisceau de ls entre la carte interface usager (connecteur MACS1 ou MACS2) et le panneau de relais du four (connecteur J3 ou J4).
3. Si le faisceau de ls est bon, remplacez le panneau de relais du four.
4. Si le problème persiste, remplacez la carte interface usager du four.
F23 Échec de communication entre la carte
d’interface usager et le panneau tactile.
1. Débranchez l’alimentation, attendez 30 secondes et rebranchez. Vériez si les conditions d’erreur sont encore présentes.
2. Vériez le l entre la carte interface usager (connecteur I2C1 ou I2C2) et le panneau tactile (connecteur I2C1 ou I2C2).
3. Si le l est bon, remplacez le panneau tactile.
4. Si le problème persiste, remplacez la carte interface usager du four.
F25
F27
La communication entre la carte interface
usager et le panneau de relais du four ne
peut être démarrée.
1. Débranchez l’alimentation, attendez 30 secondes et rebranchez.
2. Si l’erreur réapparaît, vériez la connexion entre la carte interface usager du four (connecteur MACS1 ou MACS2) et le panneau de relais du four
(connecteur J3 ou J4).
3. À l’aide du numéro de modèle et du catalogue de service, vériez si l’appareil a la bonne carte interface usager et le bon panneau de relais du four.
4. Si le problème persiste, remplacez le panneau relais du four.
5. Si le problème persiste, remplacez la carte interface usager.
F28
F29
La communication entre la carte interface
usager et le panneau tactile ne peut être
démarrée.
1. Débranchez l’alimentation, attendez 30 secondes et rebranchez.
2. Si l’erreur réapparaît, vériez si le panneau tactile est branché (vériez le faisceau de ls allant au connecteur I2C1 ou I2C2) et s’il reçoit de l’alimenta-
tion de la carte interface usager.
3. À l’aide du numéro de modèle et du catalogue de service, vériez si l’appareil a la bonne carte interface usager et le bon panneau tactile.
4. Si le problème persiste, remplacez le panneau tactile.
5. Si le problème persiste, remplacez la carte interface usager du four.
F30 Le circuit de la sonde de température du
four est ouvert (RTD)
1. Vériez si le circuit de la sonde ne serait pas ouvert ou en condition de court-circuit.
2. Vériez la résistance RTD à la température ambiante (comparez la valeur obtenue dans la charte de résistance). Si la valeur obtenue ne correspond
pas à la valeur de la charte, remplacez la sonde RTD.
3. Si le problème persiste, remplacez le panneau de relais.
F31 La sonde de température du four (RTD) est
en court-circuit.
F33 Le capteur de la sonde à viande est en
court-circuit ou trop chaud.
1. L’erreur est déclenchée si la sonde à viande perçoit une température supérieure à 392°F. Assurez-vous que la sonde à viande ne puisse pas percevoir
la température provenant d’une autre source. Si le bout de la sonde n’est pas inséré dans la viande, celui-ci va capter la température de la cavité,
laquelle peut être supérieure à 392°F (dépendant de la température réglée dans le four) et déclencher l’alarme.
2. Si la sonde à viande n’est pas complètement insérée dans le réceptacle situé à l’intérieur de la cavité du four ceci peut entrainer un court-circuit et
causer un code d’erreur. Assurez-vous que la sonde est correctement insérée dans le réceptacle.
3. Vériez la résistance de la sonde à viande à la température ambiante. Comparez cette valeur à celles dans la table de la résistance de la sonde à
viande. Si elle ne correspond pas aux valeurs du tableau, remplacez la sonde à viande.
4. Si toutes les étapes mentionnées ci-haut ont échoué, remplacez le panneau de relais du four.
F45 Vitesse du ventilateur de refroidissement
trop lente.
1. Vériez si les pales du ventilateur de refroidissement sont bloquées.
2. Conrmez que le lage du tachymètre est branché au ventilateur et à la commande du four.
3. Remplacez le ventilateur de refroidissement.
4. Remplacez la commande du four.
F46 Vitesse du ventilateur de refroidissement
trop élevée.
1. Vériez qu’il n’y ait pas d’obstruction mécanique dans le chemin de l’air.
2. Remplacez le ventilateur de refroidissement.
3. Remplacez la commande du four.
F50 A/D hors limite: Le panneau relais du four
ne peut connaître le statut des interrupteurs
(porte, moteur verrou)
1. Vériez que les branchements entre le commutateurs de la porte, le loquet de porte à moteur (LPM) et les sondes de température sont correctement
établis. Ceux-ci incluent toutes les épissures et les jonctions.
2. Remplacez la carte de relais de commande des relais du four.
F90 Échec du mécanisme du moteur verrou de
la porte du four: La commande du four ne
détecte pas que le moteur verrou de la porte
du four est en marche.
1. Débranchez l’alimentation, attendez 30 secondes et rebranchez. Essayez à nouveau de verrouiller ou déverrouiller la porte (ex: activez le Lockout ou
un cycle autonettoyant).
2. Vériez si le moteur tourne ou non. S’il ne tourne pas, vériez le faisceau de ls entre le moteur verrou et le panneau de relais. Si le faisceau de ls est
bon, vériez si il y a 120VAC au moteur lorsqu’il est sensé fonctionner pour voir si le problème est dû à un mauvais moteur (la lecture est de 120VAC
mais le moteur ne tourne pas) ou si le problème revient au panneau de relais (Tige 10 de J20 sur le panneau de relais est la sortie vers le moteur
verrou). Le moteur verrou peut aussi être vérié en appliquant 120VAC directement au moteur (Il faut commencer par le débrancher du panneau de re-
lais). Si le moteur verrou ne tourne pas lorsque 120VAC est appliqué, remplacez l’assemblé moteur verrou. Si c’est le panneau de relais qui ne fournit
pas 120VAC au moteur verrou, remplacez le panneau de relais.
3. Si le moteur tourne mais la commande de four ne peut trouver la position verrouillée ou déverrouillée (ex: le moteur tourne continuellement lorsque le
code F90 est afché) l’interrupteur verrou doit être vérié. Vériez le faisceau de ls entre l’interrupteur verrou et le panneau de relais. Vériez avec
un ohmmètre que le contact de l’interrupteur est correct (vériez la continuité avec le ohmmètre lorsque l’interrupteur est appuyé). Si l’interrupteur est
défectueux, remplacez l’assemblé moteur verrou.
4. Si toutes les étapes mentionnées ci-haut ont échoué, remplacez le panneau de relais du four.
F95 Échec du mécanisme du moteur verrou de
la porte du four. Le moteur verrou tourne
continuellement ou l’interrupteur envoie un
mauvais signal.
1. Le problème peut être causé par un interrupteur ou un panneau de relais défectueux. Si le moteur verrou fonctionne continuellement (ou comme si le
relais demeure fermé) remplacez le panneau de relais du four.
2. Si le moteur ne tourne pas continuellement remplacez l’assemblé moteur verrou.
F96 La porte du four a été détectée ouverte lors
d’un cycle autonettoyant.
1. Cette erreur survient si l’interrupteur de porte perd son contact lors d’un cycle autonettoyant. Assurez-vous que la porte du four ferme complètement et
qu’elle presse adéquatement le piston de l’interrupteur de porte lorsque cette dernière est verrouillée et assurez-vous que personne n’essaie d’ouvrir la
porte lorsque le four est en cycle autonettoyant.
2. Vériez le faisceau de ls entre l’interrupteur de porte et le panneau de relais, assurez-vous que l’interrupteur de porte est bien branché. À l’aide d’un
ohmmètre, vériez si l’interrupteur est fermé lorsque le piston est pressé. Si l’interrupteur est défectueux, remplacez-le.
3. Si l’interrupteur et le faisceau de ls sont bons, remplacez le panneau de relais.
CODES D’ERREUR POUR LA FICHE TECHNIQUE DE LA CUISINIÈRE AVEC BOUTONS DE COMMANDE À L’AVANT
Code Description de l’erreur Actions correctives suggérées
MATRICE D’ANALYSE
DU CIRCUIT
ÉLÉMENTS
Moteur Verrou
J20-10 (K13)
Lampe
J20-6 (K9)
Ventilateur Conv
Basse J20-9 (K12)
Haute J19-3 (K6)
Interr. porte
J5-7, J5-9
DLB L2
sortie
(K1)
Ventilateur
refroidissement
Basse J20-7 (K10)
Haute J20-8 (K11)
Catalyseur
d’autonettoyage
J19-2 (K5)
Cuisson
P7 (K3)
Gril
K2
Conv.
P8 (K6)
Cuisson X X X X X X X
Gril X X X
Cuisson Conv. X X X X X X X
Rôtissage Conv X X X X X X X
Nettoyage X X X X X X
Verrouillage X
Verrouillé
Déverrouillage X
Déverrouillé
Lampes X
Porte Ouverte X
Porte Fermée X
Catalyseur
d’autonettoyage
(en pressant la touche)
X X X
X
NOTES: cycles de cuisson, de gril et de convection alternés. Les ventilateurs de convection peuvent fonctionner pendant le préchauffage et peuvent fonctionner de manière intermittente pendant les fonctions de non
convection pour améliorer les performances de cuisson.
CARTE DE RELAIS DE
C
OMMANDE DU FOUR
(OVC)
PANNEAU TACTILE
(BENDER HMI)
CONTRÔLE DU FOUR
(MARS)
MACS
I2C
Résistance (ohms)
1 000 ± 4,0
1 091 ± 5,3
1 453 ± 8,9
1 654 ± 10,8
1 852 ± 13,5
2 047 ± 15,8
2 237 ± 18,5
2 697 ± 24,4
Circuit ouvert/résistance infinie
ÉCHELLE DU DÉTECTEUR DE TEMPÉRATURE
À RÉSISTANCE
Température °F (°C)
32 ± 1,9 (0 ± 1,0)
75 ± 2,5 (24 ± 1,3)
250 ± 4,4 (121 ± 2,4)
350 ± 5,4 (177 ± 3,0)
450 ± 6,9 (232 ± 3,8)
550 ± 8,2 (288 ± 4,5)
650 ± 9,6 (343 ± 5,3)
900 ± 13,6 (482 ±7,5)
Circuit de la sonde mise à la
terre à la caisse
SONDE À VIANDE TEMPÉRATURE VS RÉSISTANCE
Température °F (°C) Résistance (Kohm)
77 (25) 50.0 ± 7%
122 (50) 18.0 ± 4.9%
176 (80) 6.3 ± 3.3%
212 (100) 3.4 ± 4.6%
SYSTÈME DE COMMANDES MODULAIRE
Cet appareil est muni d’un système de commandes modulaire. Le système modulaire
comporte différentes cartes qui communiquent entre elles pour activer les fonctions
de cuisson. Les fonctions du four, si disponibles, sont activées grâce à une interface
utilisateur pour le four (IU ou TIU) et une carte de relais pour le four. Les fonctions de
la surface de cuisson, sont activées grâce à un IU/PIU et une carte de relais pour la
surface de cuisson. D’autres cartes dans le système peuvent activer des fonctions
spéciques (consultez les schémas et diagrammes sur cette che d’information).
Le fonctionnement à basse tension et l’alimentation des communications pour les
cartes modulaires sont assurés par les circuits de câbles. Les cartes qui gènèrent la
basse tension et alimentent les communications sont contrôlés par des système de
commandes individuels (consultez les schémas et diagrammes sur cette che d’infor-
mation) Ces tensions sont uniquement les tensions de fonctionnement. N’utilisez pas
ces tensions comme conrmation d’une transmission entre les cartes. La transmission
se fait grâce à une programmation logicielle sur chaque carte. Cette transmission ne
peut pas être détectée à l’aide d’un ohmmètre. La programmation est auto-contrôlée
et les afchages sur l’IU montrent les codes d’erreur selon les pannes détectées. Les
cartes individuelles ne peuvent pas être réparées sur place. Consultez les schémas
et les diagrammes contenus dans cette che d’information pour en savoir plus sur un
élément spécique.
INTERRUPTEUR DE VERROUILLAGE
PRIMAIRE (HAUT)
CAVITÉ
COUPURE
THERMIQUE
SOURCE DE
COURANT :
MONOPHASÉ
SEULEMENT
MAGNÉTRON
COUPURE
THERMIQUE
ASSEMBLAGE
DU FILTRE
MAGNÉTRON
INTERRUPTEUR DE
MONITOR INTERLOCK
RELAIS
MOTEUR
RELAI
ELECTRIQUE
RELAIS DE
COMMUTATION
TRANSFORMATEUR HAUTE TENSION
DIODE HAUTE
TENSION
CONDENSATEUR
HAUTE TENSION
INTERRUPTEUR DE
VERROUILLAGE
SECONDAIRE
TRANSFORMATEUR
BASSE TENSION
FERMÉ
LAMPE DU
FOUR
MOTEUR DE
CONVECTION
MOTEUR DE PLAQUE
TOURNANTE
NOIRE
ROUGE
BLANC
JAUNE
VERTE
BRUN
BLEU
FUSE : FUSIBLE
Lin : LIGNE ENTRANT
Lout : LIGNE DE SORTIE
Nin : NEUTRE ENTRANT
Nout : NEUTRE DE SORTIE
ASSEMBLÉE DE CONTRÔLE DE
TABLEAU D'ALIMENTATION
1 1
1
1
1
1
1
1
1
NEUTRAL/NEUTRE
L1
COOLING FAN LOW SPEED/VENT. DE REFROID. BASSE
CONVECTION FAN LOW (OPT)/VENT. DE CONV. BASSE (OPT)
CONVECTION FAN HIGH
J3 TO USER INTERFACE BOARD/MARS BOARD
LATCH MOTOR/MOTEUR VERROU
OVEN LIGHT/LAMPE HALOGÈNE
NEUTRAL/NEUTRE
L1
MEAT PROBE (OPT)/
SONDE À VIANDE
TEMPERATURE PROBE/
SONDE À TEMPÉRATURE
MOTOR DOOR LATCH SWITCH/INTERRUPTEUR DE MOTEUR VERROU
DOOR SWITCH/INTERRUPTEUR DE PORTE
COMMON/COMMUNE
PROGRAMMING HEADER/
TÊTE DE PROGRAMMATION
CONV ELEMENT
BAKE ELEMENT
SELF CLEAN CATALYST (OPT)
L2 OUT/THERM
L2 IN
BROIL/
GRILLAGE
COM L1
BROIL
J4
COOLING FAN HIGH SPEED/VENT. DE REFROID. HAUTE
CATALYST
CONV FAN
HIGH/VENT.
DE CONV.HAUTE
BAKE ELEMENT
CONV ELEMENT (OPT)
L1L1
J2 COMM TO COOLING
FAN SPEED SENSOR/(OPT)
COMM À REFROID. CAPTEUR
DE VITESSE DE VENT(OPT)
MDL
CATALYSEUR D’AUTONETTOYAGE (OPT)
SORTIE/THERM
GRIL
CATALYSEUR
VENT. DE CONV. HAUTE VITESSE
À PLAQUETTE D'INTERFACE DE UTILISATEUR/“MARS BOARD”
ÉLÉMENT DE
CONVECTION (OPT)
ÉLÉMENT DE
CUISSON
DLB
LIGNE
DOUBLE
INTERROMPUE
ENTRÉE
ÉLÉMENT DE
CONVECTION
ÉLÉMENT DE
CUISSON
MOTEUR
VERROU
COOL FAN HI
VENT.DE
REFRD HAUTE
OVEN LIGHT/
LAMPE
HALOGÈNE
CONV FAN LO
VENT. DE
CONV.BASSE
COOL FAN LO
VENT.DE
REFRD BASSE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Frigidaire FGMC2766UF Information produit

Taper
Information produit

dans d''autres langues