WIKA 32 Manuel utilisateur

Taper
Manuel utilisateur
Operating instructions
Betriebsanleitung
Mode d'emploi
Manual de instrucciones
EN
DE
FR
ES
Machine glass thermometer, model 32
Machine glass thermometer, model 32
Maschinen-Glasthermometer, Typ 32
Thermomètre industriel en verre, type 32
Termómetro de capilla, modelo 32
2
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
DE
FR
ES
Operating instructions model 32 Page 3 - 26
Betriebsanleitung Typ 32 Seite 27 - 50
Mode d'emploi type 32 Page 51 - 74
Manual de instrucciones modelo 32 Página 75 - 98
© 10/2010 WIKA Alexander Wiegand SE & Co. KG
All rights reserved. / Alle Rechte vorbehalten.
WIKA
®
is a registered trademark in various countries.
WIKA
®
ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Lire le mode d‘emploi avant de commencer toute opération !
A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo!
¡Guardar el manual para una eventual consulta!
3
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
Contents
Contents
1. General information 4
2. Design and function 5
3. Safety 6
4. Transport, packaging and storage 9
5. Commissioning, operation 10
6. Faults 19
7. Maintenance and cleaning 21
8. Dismounting, return and disposal 22
9. Specifications 25
10. Thermowells as accessories 26
4
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
1. General information
The machine glass thermometer described in the operating
instructions has been manufactured using state-of-the-art
technology. All components are subject to stringent quality and
environmental criteria during production. Our management
systems are certified to ISO 9001 and ISO 14001.
These operating instructions contain important information on
handling the instrument. Working safely requires that all safety
instructions and work instructions are observed.
Observe the relevant local accident prevention regulations and
general safety regulations for the instrument's range of use.
The operating instructions are part of the product and must
be kept in the immediate vicinity of the instrument and readily
accessible to skilled personnel at any time. Pass the operating
instructions onto the next operator or owner of the instrument.
Skilled personnel must have carefully read and understood the
operating instructions prior to beginning any work.
The general terms and conditions contained in the sales
documentation shall apply.
Subject to technical modifications.
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: TM 32.02
1. General information
5
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
2. Design and function
2.1 Overview
Case with measuring range
Glass insert with temperature scale and indicator liquid
Stem
2.2 Description
The model 32 machine glass thermometer is mainly used in
industrial applications such as machine building and also in
heating, air-conditioning and refrigeration technology.
see chapter
6.1
Straight 90° angle 135° angle
2. Design and function
6
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
It is notable for its high accuracy and very long service life (since
there is no mechanical wear).
The model 32 machine glass thermometer is available in three
sizes (200, 150 and 110 mm) and three versions (straight,
135° angle and 90° angle).
2.3 Scope of delivery
Cross-check scope of delivery with delivery note.
3. Safety
3.1 Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can
result in serious injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can
result in light injuries or damage to equipment or the
environment, if not avoided.
WARNING!
... indicates a potentially dangerous situation that can
result in burns, caused by hot surfaces or liquids, if not
avoided.
Information
... points out useful tips, recommendations and
information for efficient and trouble-free operation.
2. Design and function / 3. Safety
7
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
3.2 Intended use
The model 32 machine glass thermometer is used for measuring
the temperature in plant or machinery in closed rooms. Do not
exceed the specified limit values (see chapter 9 “Specifications”).
This instrument is not permitted to be used in hazardous areas!
The instrument has been designed and built solely for the
intended use described here, and may only be used accordingly.
The technical specifications contained in these operating
instructions must be observed. Improper handling or operation of
the instrument outside of its technical specifications requires the
instrument to be taken out of service immediately and inspected
by an authorised WIKA service engineer.
The manufacturer shall not be liable for claims of any type based
on operation contrary to the intended use.
3.3 Improper use
WARNING!
Injuries through improper use
Improper use of the instrument can lead to hazardous
situations and injuries.
Refrain from unauthorised modifications to the
instrument.
Do not use the instrument within hazardous areas.
Do not use the instrument with abrasive or viscous
media.
3. Safety
8
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
Any use beyond or different to the intended use is considered as
improper use.
Do not use this instrument in safety or emergency stop devices.
3.4 Responsibility of the operator
The instrument is used in the industrial sector. The operator is
therefore responsible for legal obligations regarding safety at work.
The safety instructions within these operating instructions, as well
as the safety, accident prevention and environmental protection
regulations for the application area must be maintained.
To ensure safe working on the instrument, the operating company
must ensure
that suitable first-aid equipment is available and aid is provided
whenever required.
that the operating personnel are regularly instructed in all
topics regarding work safety, first aid and environmental
protection and know the operating instructions and in
particular, the safety instructions contained therein.
that the instrument is suitable for the particular application in
accordance with its intended use.
that personal protective equipment is available.
3.5 Personnel qualification
WARNING!
Risk of injury should qualification be insufficient!
Improper handling can result in considerable injury and
damage to equipment.
The activities described in these operating instructions
may only be carried out by skilled personnel who have
the qualifications described below.
3. Safety
9
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
Skilled personnel
Skilled personnel, authorised by the operator, are understood to
be personnel who, based on their technical training, knowledge
of measurement and control technology and on their experience
and knowledge of country-specific regulations, current standards
and directives, are capable of carrying out the work described and
independently recognising potential hazards.
Special operating conditions require further appropriate
knowledge, e.g. of aggressive media.
4. Transport, packaging and storage
4.1 Transport
Check the instrument for any damage that may have been caused
by transport. Obvious damage must be reported immediately.
CAUTION!
Damage through improper transport
With improper transport, a high level of damage to
property can occur.
When unloading packed goods upon delivery as well
as during internal transport, proceed carefully and
observe the symbols on the packaging.
With internal transport, observe the instructions in
chapter 4.2 “Packaging and storage”.
4.2 Packaging and storage
Do not remove packaging until just before mounting.
Keep the packaging as it will provide optimum protection during
transport (e.g. change in installation site, sending for repair).
3. Safety / 4. Transport, packaging, storage
10
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
Permissible conditions at the place of storage:
Storage temperature: 0 ... 70 °C
Humidity: 35 ... 85 % relative humidity (no condensation)
Avoid exposure to the following factors:
Direct sunlight or proximity to hot objects
Mechanical vibration, mechanical shock (putting it down hard)
Soot, vapour, dust and corrosive gases
Hazardous environments, flammable atmospheres
Store the instrument in its original packaging in a location that
fulfils the conditions listed above. If the original packaging is not
available, pack and store the instrument as described below:
1. Wrap the instrument in a plastic film.
2. Place the instrument, along with shock-absorbent material and
the stem protector (if accompanying), in the packaging.
3. If stored for a prolonged period of time (more than 30 days),
place a bag containing a desiccant inside the packaging.
5. Commissioning, operation
Personnel: Skilled personnel
Tools:
Open-ended spanner for counter nut: SW 22
Open-ended spanner for immersion stem/thermowell:
SW 27 and SW 32
Allen key (for 90° version): size 3
4. Transport ... / 5. Commissioning, operation
11
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
WARNING!
Physical injuries and damage to property and the
environment caused by hazardous media
Upon contact with hazardous media (e.g. oxygen,
acetylene, flammable or toxic substances), harmful
media (e.g. corrosive, toxic, carcinogenic, radioactive),
and also with refrigeration plants and compressors, there
is a danger of physical injuries and damage to property
and the environment. Aggressive media with extremely
high temperatures and under high pressure or vacuum
may be present at the instrument.
For these media, in addition to all standard
regulations, the appropriate existing codes or
regulations must also be followed.
WARNING!
Physical injury and damage to the instrument
through hot surfaces and improper use
In operation, the thermometer can become very hot and
should not be subjected to any mechanical loading.
Do not touch the thermometer when in operation.
Thermometers must not be used for any purpose
other than for the intended use described.
Do not use the thermometer as a hand or foot hold.
CAUTION!
Physical injury through defective glass inserts
The glass insert is fragile and can lead to cut injuries.
Do not apply any pressure to the glass inserts.
Replace instruments with defective glass inserts.
Avoid touching with fingers.
5. Commissioning, operation
12
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
Prior to installation, check whether the wetted materials of the
instrument are suitable for the medium.
The materials used can be found on the delivery documentation.
5.1 Indicator
The scale divisions are permanently imprinted onto the glass
insert and consist of main and sub-divison lines. These form the
reference to the measuring range printed on the case. The exact
reading of the temperature is made by the level of the
thermometric liquid in the capillary, the column. This is made
easier by the sub-division lines. In order to ensure an optimal
reading of the temperature, the eyes should be at the same height
as the thermometer. Thus the viewing angle will be from the front.
In this way, the indicator liquid is optically enlarged.
Magnification of the indicator liquid when looking at the
thermometer from the front.
26 °C
Indicator
liquid
5. Commissioning, operation
13
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
5.2 Installation
For precise temperature measurement, the thermometer must be
installed correctly.
Installation instructions
5. Commissioning, operation
14
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
5.3 Mounting
WARNING!
Damage to property and the environment through
unsuitable sealing materials
Hot media might escape if unsuitable sealing material is
used. This can cause damage to the plant and pollution
of the environment.
Use a sealing material that is suitable for the
temperature range, and that is resistant to the medium
being measured.
Before mounting
Before starting the work, make sure that the conditions for
mounting the thermometer are met:
The plant is disconnected and free from pressure.
The plant has cooled down to ambient temperature.
There is a male thread at a suitable position in the plant.
A suitable sealing material is used.
Only use suitable, correctly sized tools for mounting.
5. Commissioning, operation
15
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
5.3.1 “Straight” and “135° angle” versions
or
1. Sealing
2. Inserting
3. Tightening the stem
4. Loosening
the counter
nut
5. Aligning
6. Tightening the
counter nut
Sealant
(e.g. PTFE, hemp, ...)
Flat gasket
or
5. Commissioning, operation
16
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
1. Loosening the
retainer screw
2. Removing the stem
or
4. Inserting the stem 5. Tightening the stem
3. Sealing
Sealant
(e.g. PTFE, hemp, ...)
Flat gasket
or
5.3.2 “90° angle” version
Allen key, size 3
5. Commissioning, operation
17
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
8. Tightening the retainer
screw
6. Inserting the case with
thermometer insert
7. Aligning
CAUTION!
Physical injury through defective glass inserts
The glass insert is fragile and can lead to cut injuries.
Do not apply any pressure to the glass inserts.
Replace instruments with defective glass inserts.
Avoid touching with fingers.
Allen key, size 3
5. Commissioning, operation
18
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
5.3.3 Fixing via the connection design (option)
Design 3, union nut
The standard version of the machine glass thermometer is design
E (male thread) This has a male thread which is available in
various thread types. With design 3 (union nut), the stems have a
union nut with corresponding female thread. The stem length and
thread types are already designed for use with thermowells.
The preceding mounting instructions are illustrated with design
E (male thread). The mounting of instruments with design 3
(union nut) is carried out with the same mounting steps. The only
difference is that, instead of the male thread, a corresponding
thermowell is built in to the plant or machinery.
Design E (male thread)
90° anglestraight 135° angle
3073092.01
3073106.01
3073114.01
5. Commissioning, operation
19
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
6. Faults
Personnel: Skilled personnel
Tools:
Open-ended spanner for counter nut: SW 22
Open-ended spanner for immersion stem/thermowell:
SW 27 and SW 32
Allen key (for 90° version): size 3
CAUTION!
Physical injuries and damage to property and the
environment
If faults cannot be eliminated by means of the listed
measures, the instrument must be taken out of operation
immediately.
Ensure that there is no longer any pressure present and
protect against being put into operation accidentally.
Contact the manufacturer.
If a return is needed, please follow the instructions
given in chapter 8.2 “Return”.
Design 3 (union nut), only with NS 200
straight 135° angle90° angle
3073181.01
3073130.01
3073122.01
5. Commissioning, operation / 6. Faults
20
11603445.02 03/2017 EN/DE/FR/ES
WIKA operating instructions model 32
EN
WARNING!
Physical injuries and damage to property and the
environment caused by hazardous media
Upon contact with hazardous media (e.g. oxygen,
acetylene, flammable or toxic substances), harmful
media (e.g. corrosive, toxic, carcinogenic, radioactive),
and also with refrigeration plants and compressors, there
is a danger of physical injuries and damage to property
and the environment. Aggressive media with extremely
high temperatures and under high pressure or vacuum
may be present at the instrument.
For these media, in addition to all standard
regulations, the appropriate existing codes or
regulations must also be followed.
For contact details see chapter 1 “General information” or
the back page of the operating instructions.
Faults Causes Measures
No indicator liquid Broken glass insert Send instrument in for
repair
Discontinuity in
the indicator
Shocks during improper
transport
Send instrument in for
repair
6. Faults
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100

WIKA 32 Manuel utilisateur