Power One PVI-AEC-EVO Quick Installation Manual

Taper
Quick Installation Manual
BATTERY PACK
For PVI-AEC-EVO
QUICK INSTALLATION GUIDE
Note: This document contains proprietary information of Power-One, Inc.
The contents of this document or any part thereof should not be reproduced or disclosed
to any third party whitout Power-One’s express written consent.
REV 2.0
BATTERY PACK
QUICK INSTALLATION GUIDE
Wiring Battery Pack to PVI-AEC-EVO
Package contents
12
Quick Installation Guide
BATTERY PACK
For PVI-AEC-EVO
QUICK INSTALLATION GUIDE
No te: Th is do cume nt co ntai ns pr op riet ary in form atio n of Po wer- One, In c.
The contents of this document or any part thereof should not be reproduced or disclosed
to any third party whitout Power-One’s express written consent.
REV 0.1.0
123
1
2
3
Battery Pack
Package contents
Wire (200 mm) + connectors (assembled)
Product description and technical parameter
The BATTERY PACK is an expansion module specifically designed for PVI-AEC-EVO which provides a back-up for the PVI-
AEC-EVO monitoring system.
The battery pack includes 4 x 1,2Vdc AAA type Ni-Mh rechargeable batteries: please refer to the below table for the
characteristic.
The PVI-AEC-EVO System is equipped with an integrated battery charger that can recharge the batteries of the BATTERY
PACK. When the batteries are used for the first time, they may not be fully charged: to obtain a full charge, the battery pack
must be connected to the PVI-AEC-EVO (powered by 24Vdc source) for a period of at least 24h.
The BATTERY PACK is able to supply the PVI-AEC-EVO in case of the 24Vdc failure but is not able to turn on the PVI-AEC-EVO
from the shut down condition.
When the system is powered by the battery pack, there are no limitation to the embedded functionalities of the
system: the presence of the battery pack provides full system operation in absence of supply voltage 24Vdc.
The battery pack is able to keep the system up for a period of approximately 30 minutes, after which the system will
shut down completely.
In the event that the system PVI-AEC-EVO is equipped with the expansion module GSM / GPRS, the absence of supply
voltage 24Vdc, will be notified by sending an SMS alert containing “W004 - AC Failure”.
Once the power supply is back, (power supply is back while the system is powered by the BATTERY PACK) another SMS
is sent, to alert about this event.
If the power supply is reconnected after a full battery discharge, the system will send an SMS alerting about a system
boot event (I005 - Wake Up).
Monitoring System
Provision for recycling of exhausted batteries
For proper disposal of exhausted batteries, it is necessary be scrapped at an authorized collection center, in
compliance with European Directive 2002/96/EC (WEEE Directive) has been acknowledged into the Italian law by
Legislative Decree Nr. 151, dated July 25, 2005.
BATTERY PACK
QUICK INSTALLATION GUIDE
Note: The batteries must be changed every 25.000 power on hours to assure a back-up data during black-out.
CAUTION!
RISK OF EXPLOSION IF BATTERIES ARE REPLACED BY A WRONG TYPE.
REPLACE BATTERIES ONLY WITH SAME MANUFACTURER PART
NUMBER.
TECHNICAL DATA
Battery Type Panasonic Model HHR60AAAH
AAA Ni-Mh Rechargeable battery
www.panasonic.com
Battery Voltage 4 x 1.2 V
Battery Rated Capacity 500 mAh
Battery Charge Current 50 mA
Max. Ambient Working Temperature +55 °C
-20 °C
Operating Humidity 25 to 95 % RH @ +40 °C
Protection Degree IP20
Useful Life (see note) 100.000 Hour (@ 40 °C Ambient Temperature)
Min. Ambient Working Temperature
Monitoring System
Connessione del Battery Pack al PVI-AEC-EVO
Contenuto della confezione
12
Guida di installazione rapida
BATTERY PACK
For PVI-AEC-EVO
QUICK INSTALLATION GUIDE
No te: Th is do cume nt co ntai ns pr op riet ary in form atio n of Po wer- One, In c.
The contents of this document or any part thereof should not be reproduced or disclosed
to any third party whitout Power-One’s express written consent.
REV 0.1.0
123
1
2
3
Battery Pack
Contenuto della confezione
Cablaggio (200 mm) + connettori (assemblati)
BATTERY PACK
GUIDA DI INSTALLAZIONE RAPIDA
Descrizione del prodotto e dati tecnici
Il Battery Pack è un modulo di espansione specificatamente sviluppato per il sistema PVI-AEC-EVO in grado di fornire un
alimentazione di back-up al sistema in caso di assenza della tensione di alimentazione.
Il Battery Pack è costituito da 4 batterie tipo AAA Ni-Mh ricaricabili: le caratteristiche tecniche delle batterie sono riportate
nella tabella di seguito.
Il sistema PVI-AEC-EVO è dotato di un caricabatterie integrato in grado di ricaricare le batterie del BATTERY PACK. Alla
prima installazione le batterie potrebbero non essere completamente cariche: per la completa ricarica delle batterie, il
BATTERY PACK deve essere lasciato connesso al PVI-AEC-EVO (alimentato dalla tensione di 24Vdc) per un tempo di 24h.
Il Battery Pack è in grado di mantenere attivo il sistema ma non è in grado di attivarlo da una condizione di sistema spento
(la connessione del solo BATTERY PACK non è sufficiente a permettere l'accensione del sistema).
L'alimentazione del sistema attraverso il BATTERY PACK non limita le funzionalità del sistema: la presenza del battery pack
assicura il completo funzionamento del sistema in assenza della tensione di alimentazione 24Vdc.
Il BATTERY PACK è in grado di mantenere il sistema attivo per un tempo di circa 30 minuti, al termine dei quali il sistema si
spegne completamente.
Nel caso in cui il sistema PVI-AEC-EVO sia accessoriato con il modulo di espansione GSM/GPRS, l'assenza della tensione di
alimentazione 24Vdc, verrà notificata attraverso l'invio di un SMS di allarme W004 - AC Failure.
Il ripristino del normale stato di funzionamento (ripristino della tensione di alimentazione del data logger durante il
periodo di alimentazione da BATTERY PACK) causa l'invio di un secondo SMS di chiusura dell'allarme.
Qualora il ripristino del normale stato di funzionamento si manifesti successivamente alla completa scarica delle batterie,
il sistema invierà l'SMS di avvio del sistema (I005 - Wake Up).
Monitoring System
Disposizioni per lo smaltimento delle batterie esaurite
For proper disposal of exhausted batteries, it is necessary be scrapped at an authorized collection center, in
compliance with European Directive 2002/96/EC (WEEE Directive) has been acknowledged into the Italian law by
Legislative Decree Nr. 151, dated July 25, 2005.
Nota: Le batterie devono essere sostituite ogni 25.000 ore di funzionamento per assicurare il back-up dei
dati in caso di black-out.
ATTENZIONE!
RISCHIO DI ESPLOSIONE IN CASO DI SOSTITUZIONE DELLE
BATTERIE CON BATTERIE DI TIPOLOGIA ERRATA. SOSTITUIRE LE
BATTERIE SOLAMENTE CON BATTERIE DELLO STESSO MODELLO.
DATI TECNICI
Tipologia di batterie Panasonic Model HHR60AAAH
AAA Ni-Mh Rechargeable battery
www.panasonic.com
Voltaggio delle batterie 4 x 1.2 V
Capacità delle batterie 500 mAh
Corrente di carica delle batterie 50 mA
Max. Temperatura operativa +55 °C
-20 °C
Umidità operativa 25 to 95 % RH @ +40 °C
Grado di protezione IP20
Vita utile (vedi nota) 100.000 ore (@ 40 °C Temperatura ambiente)
Min. Temperatura operativa
BATTERY PACK
SCHNELLINSTALLATIONSANLEITUNG
Anschluss des Battery Pack an den PVI-AEC-EVO
Packungsinhalt
BATTERY PACK
For PVI-AEC-EVO
QUICK INSTALLATION GUIDE
No te: Th is do cume nt co ntai ns pr op riet ary in form atio n of Po wer- One, In c.
The contents of this document or any part thereof should not be reproduced or disclosed
to any third party whitout Power-One’s express written consent.
REV 0.1.0
123
1
2
3
Packungsinhalt
Battery Pack
Kabel (200 mm) + Stecker (montiert)
Schnellinstallationsanleitung
12
Monitoring System
Produktbeschreibung und Technische Parameter
Das BATTERY PACK ist ein Erweiterungsmodul welches speziell als Back up System für den PVI-AEC-EVO entwickelt
wurde.
Das Battery Pack beinhaltet 4 x 1,2Vdc AAA Ni-Mh aufladbare Akkus: Detaillierte Spezifikationen entnehmen Sie bitte der
nachfolgenden Tabelle.
Das PVI-AEC-EVO System ist mit einer Batterie-Ladefunktion ausgestattet, welches die Batterie lädt. Wird die Batterie
zum ersten Mal verwendet, ist sie möglicherweise nicht vollständig geladen. Zur vollständigen Ladung muß die Batterie
mindestens 24 Stunden mit demPVI-AEC-EVO verbunden sein (Versorgung über 24V DC).
Das Battery Pack kann den PVI-AEC-EVO speisen, ist aber nicht in der Lage den PVI-AEC-EVO nach einem Systemstillstand
neu zu starten.
Wird das System mit der Batterie betrieben gibt es keinerlei Einschränkungen bzgl. der Funktionen des Systems.
Durch die Verwendung der Batterie ist der Betrieb für ca. 30 Min. auch ohne die 24V Spg. Versorung gewährleistet.
Anschließend schaltet sich das System vollständig ab.
Sollte das PVI-AEC-EVO System mit einem GSM/GPRS Modul ausgestattet sein, wird der Ausfall der
Versorgungsspannung per SMS mit der Fehlermeldung „W004-AC Failure“ gemeldet. Nach Wiederherstellung der
Spannungsversorgung wird erneut eine SMS versendet.
Wird die Versorgungsspannung erst wieder nach vollständiger Entladung hergestellt erfolgt eine Mitteilung über den
Neustart des Systems (I 005-wake up).
BATTERY PACK
SCHNELLINSTALLATIONSANLEITUNG
Hinweis zur Entsorgung von gebrauchten Batterien
Um Batterien fachgerecht gemäss der Europäischen Weisung 2002/96/EC zu entsorgen sind diese zur Sammelstelle zu
bringen.
Bemerkung: Die Batterien müssen nach 25'000 Betriebsstunden getauscht werden um die Datenspeicherung
während eines Stromausfalles zu gewährleisten.
WARNUNG!
FALLS DIE BATTERIEN DURCH EINEN FALSCHEN TYP ERSETZT
WERDEN BESTEHT EXPLOSIONSGEFAHR! BATTERIEN NUR DURCH
SOLCHE VOM GLEICHEN HERSTELLER UND MIT DER GLEICHEN
TYPENBEZEICHNUNG ERSETZEN.
Batterie Typ Panasonic Model HHR60AAAH
AAA Ni-Mh wiederaufladbare Akkus
www.panasonic.com
Batteriespannung 4 x 1.2 V
Batteriekapazität 500 mAh
Batterie Ladestrom 50 mA
Max. Arbeitstemperatur +55 °C
-20 °C
Relative Luftfeuchtigkeit 25 bis 95 % RH @ +40 °C
Schutzklasse IP20
MTBF (siehe Bemerkung) 100.000 Hour (@ 40 °C Umgebungstemperatur)
TECHNISCHE DATEN
Min. Arbeitstemperatur
Monitoring System
Pack Batterie pour PVI-AEC-EVO
Contenu de l'emballage
BATTERY PACK
For PVI-AEC-EVO
QUICK INSTALLATION GUIDE
No te: Th is do cume nt co ntai ns pr op riet ary in form atio n of Po wer- One, In c.
The contents of this document or any part thereof should not be reproduced or disclosed
to any third party whitout Power-One’s express written consent.
REV 0.1.0
123
1
2
3
Contenu de l'emballage
Battery Pack
Câble (200 mm) + connecteurs (assemblés)
Guide d'installation rapide
12
BATTERY PACK
GUIDE D'INSTALLATION RAPIDE
Description du produit et paramètres techniques
Le pack batterie est un module d'extension conçu spécialement pour le PVI-AEC-EVO qui fournit une alimentation de
secours pour le système de surveillance PVI-AEC-EVO.
Le pack batterie comprend 4 unités de 1,2 Vcc AAA de type Ni-MH rechargeables: s'il vous plaît se référer au tableau ci-
dessous pour les caractéristiques.
Le PVI-AEC-EVO est équipé d'une batterie et de son chargeur. Lorsque la batterie est utilisée pour la première fois, elle peut
être partiellement vide. Elle sera rechargée complètement une fois que le PVI-AEC-EVO sera alimenté en 24V durant 24
heures au minimum.
La batterie est en mesure d'alimenter le PVI-AEC-EVO en cas de défaillance de son alimentation 24Vdc mais n'est pas
capable de mettre sous tension le PVI-AEC-EVO lorsqu'il est à l'arrêt.
En l'absence d'alimentation 24V, la batterie permet l'utilisation du système complet, durant 30 minutes, sans aucune
limitation des fonctionnalités.
Si l'EVO-AEC-PVI est équipé du module GSM/GPRS, l'absence d'alimentation 24V sera notifiée par une alerte SMS « W004 -
AC Failure ».
Dès lors que le système sera sous tension grâce à la batterie, un autre SMS sera envoyé pour prévenir. Une fois la batterie
déchargée, le système s'éteint, jusqu'à ce que l'alimentation 24V soit à nouveau active. Alors, le SMS « I005 – Wake up »
sera envoyé pour informer du redémarrage du système.
Monitoring System
Recyclage des batteries usagées
Pour l'élimination appropriée des batteries usagées, il est nécessaire de les déposer dans un centre de collecte autorisé, en
conformité avec la Directive européenne 2002/96/CE.
Remarque: Les batteries doivent être changées tous les 25.000 heures pour assurer une sauvegarde des
données lors de coupure de courant.
ATTENTION!
RISQUE D'EXPLOSION SI LES PILES SONT REMPLACÉS PAR UN
TYPE DIFFÉRENT. REMPLACER LES BATTERIES UNIQUEMENT
LE MODELE PRECONISE PAR LE FABRICANT.
Type de batterie Panasonic Modèle HHR60AAAH
AAA Ni-MH rechargeable
www.panasonic.com
Tension de la batterie 4 x 1.2 V
Capacité nominale de la batterie 500 mAh
Courant de charge de la batterie 50 mA
Température Max. Ambiante de fonctionnement +55 °C
-20 °C
Humidité de fonctionnement 25 à 95 % RH @ +40 °C
Degré de protection IP20
Durée de vie utile (voir note) 100,000 heure
(@ 40 °C de température ambiante)
CARACTÉRISTIQUES TECHNIQUES
Température Min. Ambiante de fonctionnement
BATTERY PACK
QUICK INSTALLATION GUIDE
Monitoring System
Declaration of Conformity - Dichiarazione di Conformità
Konformitätserklärung - Déclaration de conformité
BATTERY PACK
QUICK INSTALLATION GUIDE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Power One PVI-AEC-EVO Quick Installation Manual

Taper
Quick Installation Manual

dans d''autres langues