Delta Faucet T13220-SS Manuel utilisateur

Catégorie
Articles sanitaires
Taper
Manuel utilisateur
Owners Manual
13/14 Series
Write purchased model number here.
Table of Contents:
Warranties ..................................................................................Page 2
Installation Instructions ............................................................... Pages 3 - 12
Clean and care ...........................................................................Page 12
Maintenance ............................................................................... Page 12
Cartridge Summary Reference Sheet ........................................Page 13
For additional replacement parts, visit www.deltafaucet.com
CAUTION: This system/device must be set by the
installer to ensure safe, maximum temperature.
Any change in the setting may raise the discharge
temperature above the limit considered safe and
may lead to hot water burns.
NOTICE TO INSTALLER: CAUTION! – As the
installer of this valve, it is your responsibility
to properly INSTALL and ADJUST this valve
per the instructions given. This valve does
not automatically adjust for inlet temperature
changes, therefore, someone must make the
necessary Rotational Limit Stop adjustments
at the time of installation and further adjustments
may be necessary due to seasonal water
temperature change. YOU MUST inform the
owner/user of this requirement by following the
instructions. If you or the owner/user are unsure
how to properly make these adjustments please
refer to page 6 and if still uncertain, call us at
1-800-345-DELTA.
After installation and adjustment, you must ax
your name, company name and the date you
adjusted the Rotational Limit Stop to the caution
label provided and apply or attach the label to
the back side of the closest cabinet door and
the warning label to the water heater. Leave
this Instruction Sheet for the owner’s/user’s
reference.
WARNING: This pressure balanced or
thermostatic bath valve is designed
to minimize the eects of outlet water
temperature changes due to inlet pressure
changes, commonly caused by dishwashers,
washing machines, toilets and the like. It may
not provide protection from hot water burns
when there is a failure of other temperature
controlling devices elsewhere in the plumbing
system, if the rotational limit stop is not
properly set or if the hot water temperature is
changed after the settings are made or if the
water inlet changes due to seasonal changes.
WARNING: Do not install a shut-o device on
either outlet of this valve. When this type of
device shuts o the water ow, it can defeat
the ability of the valve to balance the hot and
cold water pressures.
107528 Rev. D10/20/2020
1
107528
MultiChoice
®
Valve Trim
Installation Instructions
You May Need
T
E
F
L
O
N
13/14 Series 13/14 Series 13/14 Series
X00107528
107528 Rev. D
2
Delta HDF Limited Warranty
All parts of the Delta HDF faucet are warranted to the
original consumer purchaser to be free from defects in
material and workmanship for a period of ve (5) years.
This warranty is made to the original consumer purchaser
and shall be eective from date of purchase as shown on
purchaser’s receipt.
Delta will replace, FREE OF CHARGE, during the warranty
period, any part which proves defective in material and/or
workmanship under normal installation, use and service.
Replacement parts can be obtained from your local
dealer or distributor listed in the telephone directory or by
returning the part along with the purchaser’s receipt to our
factory, TRANSPORTATION CHARGES PREPAID, at the
address listed. THIS WARRANTY IS THE ONLY EXPRESS
WARRANTY MADE BY DELTA. ANY CLAIMS MADE
UNDER THIS WARRANTY MUST BE MADE DURING
THE FIVE YEAR PERIOD REFERRED TO ABOVE. ANY
IMPLIED WARRANTIES, INCLUDING THE IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO
THE DURATION OF THIS WARRANTY. LABOR CHARGES
AND/OR DAMAGE INCURRED IN INSTALLATION, REPAIR
OR REPLACEMENT AS WELL AS INCIDENTAL AND
CONSEQUENTIALDAMAGES CONNECTED THEREWITH
ARE EXCLUDED AND WILL NOT BE PAID BY DELTA.
Some states do not allow limitations on how long an implied
warranty lasts, or the exclusion or limitation of incidental
or consequential damages, so the above limitations or
exclusions may not apply to you.
This warranty gives you specic legal rights, and you may
also have other rights which vary from state to state.
This warranty is void for any damage to this faucet due to
misuse, abuse, neglect, accident, improper installation, any
use violative of instructions furnished by us or any use of
replacement parts other than genuine Delta parts.
© 2020 Delta Faucet Company
Parts and Finish. All parts (other than electronic parts and batteries) and finishes of Delta® faucets purchased from authorized Delta sellers are warranted to the original
consumer purchaser to be free from defects in material and workmanship for as long as the original consumer purchaser owns the home in which the faucet was first
installed. For commercial purchasers, (a) the warranty period is ten (10) years for multi-family residential applications and (b) five (5) years for all other commercial
applications, in each case from the date of original purchase. For purposes of this warranty, the term “multi-family residential application” refers to the purchase of the
faucet from an authorized Delta seller by a purchaser who owns but does not live in the residential dwelling in which the faucet is initially installed, such as in a rented or
leased single unit or multi-unit detached home (duplex or townhome), or a condominium, apartment building or community living center. The following installations are not
considered multi-family residential applications, are excluded from the 10-year warranty and are subject to the 5-year warranty: industrial, institutional or other business
premises, such as a dormitory, hospitality premises (hotel, motel or extended stay location), airport, educational facility, long- or short-term healthcare facility (hospital,
rehabilitation center, nursing, assisted or staged-care living unit), public space or common area.
Parts and Finish for Delta® Recertified Faucets. Delta Faucet Company offers for sale on deltafaucet.com Delta® Recertified faucets. All parts (other than electronic
parts and batteries) and finishes of these Delta® Recertified faucets are warranted to the original consumer purchaser to be free from defects in material and workmanship
for ten (10) years from the date of original purchase. For commercial purchasers, the warranty period is one (1) year from the date of original purchase.
Electronic Parts. Electronic parts (other than batteries), if any, of Delta® faucets purchased from deltafaucet.com or authorized Delta sellers are warranted to the original
consumer purchaser to be free from defects in material and workmanship for five (5) years from the date of original purchase or, for commercial purchasers, for one (1)
year from the date of original purchase. No warranty is provided on batteries.
What We Will Do. Delta Faucet Company will repair or replace, free of charge, during the applicable warranty period (as described above), any part or finish that proves
defective in material and/or workmanship under normal installation, use and service. If repair or replacement is not practical, Delta Faucet Company may elect to refund
the purchase price in exchange for the return of the product. These are your exclusive remedies.
What Is Not Covered. Because Delta Faucet Company is unable to control the quality of Delta products sold by unauthorized sellers, unless otherwise prohibited by law,
this warranty does not cover Delta products purchased from unauthorized sellers.
Any labor charges incurred by the purchaser to repair, replace, install or remove this product are not covered by this warranty. Delta Faucet Company shall not be liable
for any damage to the faucet resulting from reasonable wear and tear, outdoor use, misuse (including use of the product for an unintended application), freezing water,
abuse, neglect or improper or incorrectly performed installation, maintenance or repair, including failure to follow the applicable care and cleaning instructions. Delta Faucet
Company recommends using a professional plumber for all installation and repair of faucets. We also recommend that you use only genuine Delta® replacement parts.
What You Must Do To Obtain Warranty Service or Replacement Parts. A warranty claim may be made and replacement parts may be obtained by calling 1 800 345
DELTA (3358) or by contacting us by mail or online as follows (please include your model number and date of original purchase):
In the United States and Mexico: In Canada:
Delta Faucet Company Masco Canada Limited, Plumbing Group
Product Service Technical Service Centre
55 E. 111th Street 350 South Edgeware Road
Indianapolis, IN 46280 St. Thomas, Ontario, Canada N5P 4L1
Attention: Warranty Service Attention: Warranty Service
www.deltafaucet.com/service-parts/contact-us http://www.deltafaucet.ca/customersupport/assistance.html
Proof of purchase (original sales receipt) from the original purchaser must be made available to Delta Faucet Company for all warranty claims unless the purchaser has
registered the product with Delta Faucet Company or the product is a Delta® Recertified product purchased from deltafaucet.com. This warranty applies only to Delta®
faucets manufactured after January 1, 2019 and installed in the United States of America, Canada and Mexico.
Limitation on Duration of Implied Warranties. Please note that some states/provinces (including Quebec) do not allow limitations on how long an implied warranty
lasts, so the below limitations may not apply to you. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, ANY IMPLIED WARRANTY, INCLUDING THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE, IS LIMITED TO THE STATUTORY PERIOD OR THE DURATION
OF THIS WARRANTY, WHICHEVER IS SHORTER.
Limitation of Special, Incidental or Consequential Damages. Please note that some states/provinces (including Quebec) do not allow the exclusion or limitation of
special, incidental or consequential damages, so the below limitations and exclusions may not apply to you. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE
LAW, THIS WARRANTY DOES NOT COVER, AND DELTA FAUCET COMPANY SHALL NOT BE LIABLE FOR, ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL
DAMAGES (INCLUDING LABOR CHARGES TO REPAIR, REPLACE, INSTALL OR REMOVE THIS PRODUCT), WHETHER ARISING OUT OF BREACH OF ANY
EXPRESS OR IMPLIED WARRANTY, BREACH OF CONTRACT, TORT, OR OTHERWISE. DELTA FAUCET COMPANY SHALL NOT BE LIABLE FOR ANY DAMAGE
TO THE FAUCET RESULTING FROM REASONABLE WEAR AND TEAR, OUTDOOR USE, MISUSE (INCLUDING USE OF THE PRODUCT FOR AN UNINTENDED
APPLICATION), FREEZING WATER, ABUSE, NEGLECT OR IMPROPER OR INCORRECTLY PERFORMED INSTALLATION, MAINTENANCE OR REPAIR,
INCLUDING FAILURE TO FOLLOW THE APPLICABLE INSTALLATION, CARE AND CLEANING INSTRUCTIONS. Notice to residents of the State of New Jersey: The
provisions of this warranty, including its limitations, are intended to apply to the fullest extent permitted by the laws of the State of New Jersey.
Additional Rights. This warranty gives you specific legal rights, and you may also have other rights which vary from state/province to state/province.
This is Delta Faucet Company’s exclusive written warranty and the warranty is not transferable.
If you have any questions or concerns regarding our warranty, please contact us as provided above or view our Warranty FAQs at www.deltafaucet.com.
Limited Warranty on Delta
®
Faucets
© 2020 Delta Faucet Company
107528 Rev. D
1
MultiChoice
®
Rough-In Installation
(When your product requires)
3
SHUT OFF WATER SUPPLIES.
Consider the type and thickness of your
finished wall before placing your stringer
back plate.
Install the body (1) so the surface of the
finished wall is flush with the front of the
plasterguard (2) ± 3/8". Note: For
models with stops (3), plasterguard
must be flush or subflush 3/8" to
A.
B.
finished wall.
Mount body using the two stringer
mounting holes (4) on the bracket.
Make sure the word “UP” (5) is on top of
the valve body when installing.
1
2
5
4
4
1
2
3
Distance (1) from the stringer (2) to the
front of the plasterguard is 2.8" (71 mm).
If a thin wall is used, be sure to have the
plasterguard behind the wall, otherwise
the wall should always be flush with the
front of the plasterguard. See instruction
on the bag for thin wall mounting.
107528 Rev. D
4
Connect valve body to water supplies using
the proper fittings for your valve body type
(copper tubing, iron pipe or Pex). Note: (1)
is the cold inlet port and (2) is the hot
inlet port.
If either of the two outlet ports is to be
unused, seal the port with a pipe plug.
Remove bonnet (1).
NOTICE: Avoid soldering at high
temperatures. Components of the rough
could become damaged.
Be sure stops (2) are removed from the
w/stops version before soldering. Do not
install stops before soldering.
If you are making a BACK TO BACK
OR REVERSE INSTALLATION (hot on
right and cold on left) install the valve
body as described, but the water supply
lines will be reversed. Note: (1) is the
hot inlet port and (2) is the cold inlet
port.
Copper Tubing Iron Pipe
Pex
C.
1
2
1
2
1
2
D.
1
2
107528 Rev. D
5
Connect top outlet (1) to shower pipe with
proper fittings.
Connect bottom outlet (2) to tub spout pipe
with proper fittings.
Pipe (3) between valve body and tub spout
must be a minimum of 1/2" (13 mm) copper
pipe or 1/2" (13 mm) iron pipe in a straight
drop no less than 8" (203 mm) but no more
than 18" (457 mm) long with only one iron
pipe or copper 90 degree elbow to the tub
spout nipple. Do not use PEX tubing for tub
spout drop.
To flush the system of debris, remove bonnet nut
(1).
Prepare the area for water spray.
Slowly turn on the water supplies to purge the
system for 30 seconds.
After flushing, install the cartridge and bonnet nut.
Turn cartridge stem counter clockwise until it
stops.
FOR MODELS WITH STOPS, install the
stops but leave them full open. Install stops as
follows:
Thread nut (2) onto stem (3) as shown. Then
press stem and nut assembly into body and
tighten using a 3/8”,6 point, deep well socket.
With a flat head screwdriver, adjust stem
clockwise to close and counterclockwise to
open.
Plug the tub spout and/ or shower outlet(s)
with the appropriate fitting for your piping.
Test for leaks.
After testing, turn off the valve by rotating the
cartridge stem fully clockwise.
E.
F.
1
2
3
PRESSURE TESTING & FLUSHING THE
INSTALLATION
1
1
3
2
2
3
107528 Rev. D
2
Cartridge Installation
A.
Turn off water supplies. Remove bonnet
nut (1) and test cap (2) from the body. If
this is not a thin wall mounting, the entire
plasterguard (3) may be removed. If screen
(4) is in place, remove before installing
cartridge.
Back to back Installation C.
For back to back or reverse installations
(hot on right and cold on left) insert the
cartridge with the “hot side” on the right.
If you are not making a reverse or back
to back installation skip this step and
continue with step 2C.
Slide bonnet nut (1) over the cartridge
and thread onto the body. Hand tighten
securely.
6
Normal Installation (changes not required)
Reverse
Installation
Cold
Hot
1
2
4
3
1
Rotate valve cartridge (1) so the words
“HOTTER COLDER” (2) appear on the top.
Insert cartridge assembly into rough-in body.
A light coating of plumbers grease applied to
o-rings may aid in assembly. Make sure the
key (3) on the cartridge is fully engaged with
the slot in the brass body (4).
B.
1
3
2
4
107528 Rev. D
58045
3
Shower Head and Tub Spout Installation
A.
FOR SHOWER HEAD INSTALLATION: Connect top
outlet (1) to shower arm (2) with proper ttings. To
prevent damage to nish on shower arm, insert wall end
of shower arm into shower ange (3) before screwing
arm into riser connection. Thread shower head (4) onto
shower arm. Apply plumber tape to pipe threads on both
ends. Do not overtighten shower head.
B-1
B-1: To combine the two showers, insert the top tab (1) on the hand shower into the slot (2) of
the shower head. Push the hand shower into the shower head until the two parts snap together.
B-2: To combine the two showers, push the hand shower into the shower head, then pull down
on the hand shower until locked with the shower head.
If the shower head moves when removing the hand shower, hand tighten the connection between
the shower head and the shower arm.
To change spray modes, turn the lever (3) left or right to the desired setting. Turn knob (4) to
change between shower head only, shower head and hand shower or hand shower only.
7
B-2
1
3
2
4
1
2
3
4
3
4
Installation
107528 Rev. D
8
FOR TUB SPOUT INSTALLATION:
Refer to the installation instructions supplied with your spout. Do not connect deck mount spouts to
in-wall valves. Do not use hand showers connected in lieu of a tub spout to a tub/shower valve. Do not
use PEX tubing for tub spout drop.
107528 Rev. D
4
IMPORTANT:
The Rotational Limit Stop is used to limit the
amount of hot water available such that, if set
properly, the user will not be scalded if the
handle accidentally is rotated all the way to “hot”
when a person is showering or lling a tub. The
rst position allows the LEAST amount of hot
water to mix with the cold water in the system.
In the rst position the water will be the coldest
possible when the handle is turned all the way
to hot. As you move the Rotational Limit Stop
counterclockwise, you progressively add more
and more hot water in the mix. The last position
to the left will result in the greatest amount of hot
water to the mix, and the greatest risk of scald
injury if someone accidentally turns the valve
handle all the way to the hot side while showering
or lling a tub.
WARNING: In some instances, setting the
Rotational Limit Stop in the hottest position
(full counterclockwise) could result in scald
injury. It is necessary to adjust the Rotational
Limit Stop so that the water coming out of the
valve will not scald the user when the handle
of the valve is rotated to the hot side.
According to the majority of industry standards,
the maximum allowable temperature of the water
exiting the valve is 120°F (Your local plumbing
codes may require a water temperature less than
120°F).
• The Rotational Limit Stop may need to be re-
adjusted seasonally if the inlet water temperature
changes. For example, during the winter, the
cold water temperature is colder than it is
during the summer which could result in varying
outlet temperatures. A water temperature for
a comfortable bath or shower is typically
between 90°F - 110°F.
• Run the water so that the cold water is as
cold as it will get and hot water is as hot as
it will get. Place the handle on the stem (see
page 8, step 4C) and rotate the handle coun-
terclockwise until the handle stops.
• Place a thermometer in a plastic tumbler
and hold in the water stream. If the water
temperature is above 120°F, the Rotational
Limit Stop must be repositioned clockwise to
decrease valve outlet water temperature to
be
less than 120°F or to meet the
requirements of
your local plumbing codes.
• To adjust the temperature of the water
coming out of the valve, pull the disc back
to a position where it is possible to remove
the Rotational Limit Stop and readjust the
teeth
engagement position to the desired
temperature. Clockwise will decrease the
outlet temperature, counterclockwise will
increase the outlet temperature. Temperature
change per tooth (notch) could be 4° - 16°F
based on inlet water conditions. Repeat as
necessary. Push disc until fully seated.
WARNING: Failure to re-install Disc after
setting Rotational Limit Stop could result
in scald injury.
• MAKE SURE COLD WATER FLOWS
FROM THE VALVE FIRST. MAKE SURE
WATER FLOWING FROM THE VALVE AT
THE HOTTEST FLOW POSSIBLE DOES
NOT EXCEED 120°F OR THE MAXIMUM
ALLOWED BY YOUR LOCAL PLUMBING
CODE.
9
Adjusting the Rotational Limit Stop
Hotter
Disc
Stem
1st Position
A
-For RLS With Removable Disc
107528 Rev. D
IMPORTANT:
The Rotational Limit Stop is used to limit the
amount of hot water available such that, if set
properly, a scald injury is less likely to occur if the
handle accidentally is rotated all the way to “hot”
when a person is showering or lling a tub. The
rst position allows the LEAST amount of hot
water to mix with the cold water in the system.
In the rst position the water will be the coldest
possible when the handle is turned all the way
to hot. As you move the Rotational Limit Stop
counterclockwise, you progressively add more
and more hot water in the mix. The last position
to the left will result in the greatest amount of hot
water to the mix, and the greatest risk of scald
injury if someone accidentally turns the valve
handle all the way to the hot side while showering
or lling a tub.
WARNING: In some instances, setting the
Rotational Limit Stop in the hottest position
(full counterclockwise) could result in scald
injury. It is necessary to adjust the Rotational
Limit Stop so that the water coming out of the
valve will not scald the user when the handle
of the valve is rotated to the hot side.
According to the majority of industry standards,
the maximum allowable temperature of the water
exiting the valve is 120°F (Your local plumbing
codes may require a water temperature less than
120°F).
• The Rotational Limit Stop may need to be re-
adjusted seasonally if the inlet water temperature
changes. For example, during the winter, the
cold water temperature is colder than it is
during the summer which could result in varying
outlet temperatures. A water temperature for
a comfortable bath or shower is typically
between 90°F - 110°F.
• Run the water so that the cold water is as
cold as it will get and hot water is as hot as
it will get. Place the handle on the stem (see
page 8, step 4C) and rotate the handle coun-
terclockwise until the handle stops.
• Place a thermometer in a plastic tumbler
and hold in the water stream. If the water
temperature is above 120°F, the Rotational
Limit Stop must be repositioned clockwise to
decrease valve outlet water temperature to
be
less than 120°F or to meet the
requirements of
your local plumbing codes.
• To adjust the temperature of the water
coming out of the valve, pull the white
Rotational Limit Stop (1) outward and rotate.
Clockwise rotation will decrease the outlet
temperature, counterclockwise rotation will
increase the outlet temperature. Temperature
change per tooth (notch) could be 4° - 16°F
based on inlet water conditions. Repeat as
necessary. When nished, make sure that the
Rotational Limit Stop is fully retracted into the
seated position. WARNING: Do not take the
Rotational Limit Stop apart.
• MAKE SURE COLD WATER FLOWS
FROM THE VALVE FIRST. MAKE SURE
WATER FLOWING FROM THE VALVE AT
THE HOTTEST FLOW POSSIBLE DOES
NOT EXCEED 120°F OR THE MAXIMUM
ALLOWED BY YOUR LOCAL PLUMBING
CODE.
10
Hotter
Cooler
1
1
B
-For RLS With Pull/Turn Adjustment
RLS with pull/turn adjustment
107528 Rev. D
5
Trim Installation
Slide O-ring (1) over cartridge and the
bonnet nut (2). The O-ring, which acts as
a spacer to steady the sleeve, should rest
behind the bonnet nut.
If your model requires a spacer (3), insert
it into the sleeve (4) and push it to the
front. Slide the sleeve over the cartridge,
body and O-ring.
Using an Allen wrench to secure the set
screw (1), install the handle (2) onto the
stem and tighten set screw. Insert plug
button (3) (if your model has one) into
set screw hole. Adjust the sleeve (4) to
minimize the gap between the sleeve &
handle.
Note: Adust for up to 1" thick wall. For thick
wall installation, visit delta faucet website,
check "view technical specication" of the
models you bought, order the appropriate
thick wall installation kit RP to get additional
1 3/4" wall thickness.
B-1: Secure the escutcheon (1) and backplate
(2) (if your model has one) to the bracket
(3) using the 2 screws (4) provided. Do not
overtighten escutcheon screws. Press the
cover (5) onto the escutcheon (1) when your
product includes the cover.
B-2: Install bracket (5) over the cartridge
body using the 2 screws (6) provided. Install
escutcheon (7) by placing it over the bracket
as shown and rotating it to lock the tabs (8).
Secure the escutcheon to the bracket using set
screw (9).
11
A.
C-1
2
4
1
3
1
2
1
3
B-1
B-2
3
2
1
4
5
6
7
5
9
8
8
4
4
3
107528 Rev. D
Clean and Care
Care should be given to the cleaning
of this product. Although its nish is
extremely durable, it can be damaged by
harsh abrasives or polish. To clean, simply
wipe gently with a damp cloth and blot dry
with a soft towel.
Warning: Scrubbing Bubbles
®
Bathroom
Cleaner and Lysol
®
Basin Tub and Tile
Cleaner must not be used on the clear knob
handles and levers. Use of these cleaners
can result in cracked or severely damaged
handles. If overspray gets onto the handles,
immediately wipe them dry with a soft
cotton cloth.
Maintenance
Faucet leaks from tub spout/shower head:
SHUT OFF WATER SUPPLIES.
Replace seats and springs–Repair
Kit RP4993. Check condition of lower O-rings and
replace if necessary RP14414. See Helpful Hints 1,
2, & 3.
If leak persists:
SHUT OFF WATER SUPPLIES.
Replace valve cartridge RP46074.
See Helpful Hints 1, 2, 3, 4 & 5
Unable to maintain constant
water temperature:
Replace housing assembly with RP46074 or follow
instructions in Helpful Hints 1, 2, 3, 4 & 5.
Helpful Hints:
1. Before removing valve cartridge assembly for any
maintenance, be sure to note the position of the
rotational limit stop on the cap. The valve cartridge
assembly must always be put back in the same
position. BE SAFE! After you have nished the
installation, turn on valve to make sure COLD
WATER FLOWS FIRST.
2. To remove valve cartridge from body, shut o
water supplies and remove handle and bonnet nut.
Do not pry the valve cartridge out of the body with
a screwdriver. Place handle on stem and rotate
counterclockwise approximately 1/4 turn after the
stop has been contacted. Lift valve cartridge out
of body.
3. To remove seats and springs.
Remove valve cartridge. Separate cap assembly
from the housing assembly by rotating the cap
assembly counterclockwise 90 o (degrees).
Separate cap and housing assemblies.
4. If the water in your area has lime, rust, sand
or other contaminants in it, your pressure
balance valve will require periodic inspection.
The frequency of the inspection will depend
on the amount of contaminants in the water. To
inspect valve cartridge remove it and follow the
steps in note 1 above. Turn the valve to the full
mix position and shake the cartridge vigorously.
If there is a rattling sound, the unit is functional
and can be reinstalled following instructions given
in note 1 above. If there is no rattle, replace the
housing assembly with the proper RP.
5. Push disc until fully seated. See page 9 for
more details
12
Install adapter (1) on cartridge stem (6) with
screw (2).
Thread set screw (4) into handle (3) slightly,
put handle (3) on adapter (1) , hold and adjust
the handle (3) at OFF position to ensure it
well aligned with sleeve (7). Then tighten set
screw (4).
Apply pressure, insert button (5) until properly
seated. Adjust the sleeve (7) to minimize the
gap between the sleeve & handle.
C-2
3
6
2
4
1
5
7
107528 Rev. D
Cartridge Summary Reference Sheet
Monitor
®
Series 1300/1400
Cartridge shipped before March 2006.
Cartridge shipped in July 2006 and after
(prior to MultiChoice
®
transition).
Shorter lower
housing
Blue or
o-white
White
Shorter lower
housing
White
Blue
Order RP19804 to replace cartridge. Order RP19804 to replace cartridge.
MultiChoice
®
13/14
Cartridge shipped from March 2006 to August 2014. Cartridge shipped in August 2014 and after.
Longer lower
housing
Grey
O-white
Longer lower
housing
Grey
O-white
Order RP46074 to replace cartridge. Order RP46074 to replace cartridge.
NOTE: A running change for MultiChoice
®
13/14 valves began August 2014, and
features a new Rotational Limit Stop.
MultiChoice
®
13/14 (Ceramic)
Cartridge shipping in select models (-CER).
Grey
White
Order RP74236 to replace cartridge.
13
107528 Rev. D
Instrucciones para la
Instalación del Accesorio
para Válvulas MultiChoice
®
Manual para los
Propietarios
13/14 Series
Escriba aquí el número del modelo comprado.
Usted puede necesitar
Contenido:
Garantías ....................................................................................Page 2
Instrucciones de Instalación .......................................................Pages 3 - 12
Limpieza y Cuidado de su Liave.................................................Page 12
Mantenimiento ............................................................................ Page 12
Hoja resumen de referencia para el cartucho ............................Page 13
Para las piezas de repuesto adicionales, visite www.deltafaucet.com
Límite Rotacional y aplicar o jar la etiqueta al
dorso de la puerta del gabinete más cercano y la
etiqueta de aviso al calentador de agua. Deje la
Hoja de Instrucciones para referencia del dueño/
usuario.
ADVERTENCIA: Esta válvula de presión
balanceada y termostática está diseñada
para minimizar los efectos de los cambios de
temperatura de agua por causa de los cambios
de presión en el agua de entrada, comúnmente
causados por lavadoras de platos, lavadoras
de ropa, inodoros, y otros aparatos por el
estilo. Puede no proporcionar protección de
quemaduras de agua caliente cuando hay
alguna falla de otros aparatos para el control
de temperatura en otro sitio en el sistema de
plomería. También no proporcionará protección
si el tope del límite rotacional la temperatura
no está apropiadamente jo o si cambia la
temperatura del agua caliente después de
hacer los ajustes o si los cambios del gua de
entrada son por los cambios estacionales.
ADVERTENCIA: No instale un aparato de corte
o cierre en cualquiera de las tomas de esta
válvula. Cuando este tipo de aparato cierra el
ujo de agua, puede hacer fallar la habilidad de
la válvula de balancear las presiones del agua
caliente y fría.
El instalador debe apostar este systema/divisa para
garantizar temperatura maximo y seguro. Cualqueir
cambio en el ajuste puede subir la temperatura
del agua de descarga sobre el límite considerado
seguro y puede resultar en quemaduras de agua
caliente.
AVISO PARA EL INSTALADOR:
PRECAUCIÓN – Como instalador de esta
válvula, es su responsabilidad de INSTALAR Y
AJUSTAR apropiadamente esta válvula como
se describe en las instrucciones, por lo tanto,
debe haber una persona para hacer los ajustes
necesarios del Tope del Límite Rotacional y del
pomo para la temperatura en el momento que
se haga la instalación y pueda necesitar ajustes
adicionales por los cambios estacionales de la
temperatura del agua. USTED DEBE informarle
al dueño/usuario sobre este requisito siguiendo
las instrucciones. Si usted o el dueño/usuario
no están seguros como hacer estos ajustes
apropiadamente, por favor reérase al Página
6 y si todavía no está seguro, llámenos al
1-800-345-DELTA.
Después de hacer la instalación y el ajuste,
usted puede agregarle a la etiqueta de aviso
proporcionada, su nombre, el nombre de
lacompañía y la fecha cuando ajustó el Tope del
compañía y la fecha cuando ajustó el Tope del
1
T
E
F
L
O
N
107528
107528 Rev. D10/20/2020
107528 Rev. D
2
Garantia Limitada de Delta HDF
Todas las piezas de la llave Delta HDF están
garantizadas al dueño original de estar libres de
defectos en materiales y en la mano de obra por un
período de cinco (5) años. Esta garantía se hace al
dueño original y será efectiva el día de la compra como
se ve en el recibo de compra.
Delta reemplazará, LIBRE DE CARGO, durante el
período de la garantía, cualquier pieza que resulte
defectuosa en materiales y/o en la mano de obra bajo
instalación, uso y servicio normal. Las piezas de
repuesto pueden ser obtenidas de su comerciante o
distribuidor local que se encuentran en la guía telefónica
o si usted devuelve la pieza con el recibo de compra
a nuestra fabrica, Y LOS CARGOS DE TRANSPORTE
PAGADOS CON ANTELACION, a la dirección dada.
ESTA GARANTIA ES LA UNICA GARANTIA EXPRESA
DE DELTA. CUALQUIER RECLAMO HECHO BAJO
ESTA GARANTIA TIENE QUE SER HECHO DURANTE
EL PERIODO DE CINCO AÑOS A QUE SE REFIERE
ARRIBA. CUALQUIER GARANTIA IMPLICITA,
INCLUYENDO LA GARANTIA IMPLICITA DE
COMERCIALIZACION O CONVENIENCIA PARA UN
PROPOSITO PARTICULAR, SON LIMITADOS EN
DURACION A LA DURACION DE ESTA GARANTIA.
LOS CARGOS PARA LA MANO DE OBRA Y/O DAÑOS
INCURRIDOS EN LA INSTALACION, REPARACION O
REEMPLAZO, ASI COMO LOS DAÑOS INCIDENTALES
O CONSECUENTES CONECTADOS CON
ELLOS SON EXCLUIDOS Y NO SERAN PAGADOS
POR DELTA.
Algunos estados no permiten limitaciones al tiempo que
dura la garantía implícita, o la exclusión o limitación de
los daños incidentales o consecuentes, así que la
limitación o exclusión expresada arriba puede no ser
aplicable a usted.
Esta garantía le da a usted derechos legales especícos
y usted puede también tener otros derechos que varían
de estado a estado.
Esta garantía es nula por cualquier daño a esta llave
que sea el resultado del mal uso, abuso, negligencia,
accidente, instalación impropia, cualquier uso en
violación de las instrucciones suministradas por
nosotros o cualquier uso de piezas de repuesto que no
sean piezas genuinas Delta.
© 2020 Delta Faucet Company
Piezas y Acabado. Todas las piezas (excepto los componentes electrónicos y las pilas) y los acabados de los grifos Delta Faucet® comprados de vendedores autor-
izados por Delta están garantizados al consumidor comprador original de estar libres de defectos en material y fabricación durante el tiempo que el comprador original
sea propietario de la vivienda en la que el grifo/la llave de agua fue originalmente instalada. En el caso de los consumidores comerciales, (a) el período de garantía
es de diez (10) años para aplicaciones multifamiliares (apartamentos y condominios) y (b) cinco (5) años para todos las otras aplicaciones comerciales, en cada caso
a partir de la fecha de compra. Para los propósitos de esta garantía, el término “aplicación multifamiliar residencial” se refiere a la compra del grifo de un vendedor
autorizado por Delta por el comprador propietario que no vive en la vivienda residencial donde se instaló inicialmente la llave de agua, como en una unidad alquilada
o arrendada, o unidad o vivienda unifamiliar separada (dúplex o casas adosadas), o un condominio, edificio de apartamentos o centro de vivienda comunitaria. Las
siguientes instalaciones no se consideran aplicaciones multifamiliares residenciales, están excluidas de la garantía de 10 años y están sujetas a la garantía de cinco
años: instalaciones industriales, institucionales u otras instalaciones comerciales, como dormitorios, instalaciones de hotelería (hotel, motel o una alberga para estadías
prolongadas), aeropuerto, centro educativo, centro de atención de salud a corto o largo plazo (hospital, centro de rehabilitación, asilo de ancianos, unidad de vivienda
asistida o una unidad residencial de cuidado), espacio público o área común.
Piezas y acabados para grifos recertificados Delta®. Delta Faucet Company ofrece para la venta en deltafaucet.com llaves de agua/grifos recertificados Delta®. Todas
las piezas electrónicas (excepto las partes electrónicas y las pilas) y los acabados de estos grifos recertificados Delta® están garantizados al consumidor comprador
original de estar libres de defectos en material y fabricación durante diez (10) años a partir de la fecha de compra. Para los consumidores comerciales, el período de
garantía es por un (1) año a partir de la fecha de compra.
Piezas electrónicas. Las piezas electrónicas (excepto las pilas), si las hay, de las llaves de agua Delta® compradas de deltafaucet.com o vendedores autorizados por
Delta están garantizadas al consumidor comprador original de estar libres de defectos en material y fabricación durante cinco (5) años a partir de la fecha de compra o
para los consumidores comerciales, por un (1) año a partir de la fecha de compra. No se garantizan las pilas.
Lo que haremos. La compañía Delta Faucet Company reparará o reemplazará, sin costo alguno, durante el período de garantía aplicable (como descrito arriba)
cualquier pieza o acabado que demuestre ser defectuosa en material y/o fabricación bajo la instalación, el uso y el servicio normal. Si la reparación o el reemplazo no
es práctico, Delta Faucet Company puede optar por reembolsarle el precio de compra a cambio de la devolución del producto. Estos son sus remedios exclusivos.
Lo que no cubre. Debido a que Delta Faucet Company no puede controlar la calidad de los productos Delta vendidos por vendedores no autorizados, a menos que la
ley lo prohíba, esta garantía no cubre los productos Delta comprados a vendedores no autorizados.
No cubre cualquier gasto de labor incurrido por el comprador para reparar, reemplazar, instalar o desmontar este producto. Delta Faucet Company no es responsable por
cualquier daño al grifo que resulte del desgaste razonable, uso en el exterior, uso indebido, (incluyendo el uso del producto para una aplicación indebida), agua helada,
abuso, negligencia o la instalación, el mantenimiento o la reparación incorrecta, incluido el incumplimiento de las instrucciones de cuidado y limpieza correspondientes.
Delta Faucet Company recomienda el uso de los servicios de un plomero profesional para toda instalación y reparación de los grifos. También recomendamos que use
solo piezas de repuesto genuinas Delta®.
Lo que usted debe hacer para obtener servicio de garantía o piezas de repuesto. Se puede hacer un reclamo de la garantía y se pueden obtener piezas de repuesto
llamando al 1-877-345-DELTA (3358) o contactándonos por correo postal o electrónico como indicado (favor incluya el número del modelo y la fecha de compra):
En los Estados Unidos y México: En Canadá:
Delta Faucet Company Masco Canada Limited, Plumbing Group
Product Service Technical Service Centre
55 E. 111th Street 350 South Edgeware Road
Indianapolis, IN 46280 St. Thomas, Ontario, Canada N5P 4L1
Attention: Warranty Service Attention: Warranty Service
www.deltafaucet.com/service-parts/contact-us http://www.deltafaucet.ca/customersupport/assistance.html
El comprobante de compra (recibo de venta original) del comprador original debe ser disponible a Delta Faucet Company para todos los reclamos de garantía a menos
que el comprador haya registrado el producto en Delta Faucet Company o es un producto recertificado de Delta® comprado de deltafaucet.com. Esta garantía aplica
solo a las llaves de agua/grifos Delta® fabricados después de enero 1, 2019 e instalados en los Estados Unidos de América, Canadá y México.
La limitación de la duración de las garantías implícitas. Favor tomar nota que algunos estados/provincias (incluyendo Quebec) no permiten las limitaciones de
la duración de una garantía implícita por lo que las limitaciones a continuación puedan no aplicarle. HASTA EL ALCANCE MÁXIMO EN QUE LA LEY LO PERMITA,
CUALQUIER GARANTÍA IMPLÍCITA, INCLUIDAS LAS GARANTÍAS IMPLÍCITAS DE COMERCIABILIDAD Y DE IDONEIDAD PARA UN PROPÓSITO PARTICULAR,
ESTÁ LIMITADA AL PERÍODO LEGAL O A LA DURACIÓN DE ESTA GARANTÍA, LO QUE SEA MÁS CORTO.
Limitación de daños especiales, incidentales o consiguientes. Favor de tomar nota que algunos estados/provincias (incluyendo Quebec) no permiten la exclusión
o limitación de daños especiales, incidentales o consecuentes, por lo que estas limitaciones y exclusiones puedan no aplicarle. HASTA EL ALCANCE EN QUE LA
LEY LO PERMITA, ESTA GARANTÍA NO CUBRE Y DELTA FAUCET COMPANY NO SE HACE RESPONSABLE, POR NINGÚN DAÑO ESPECIAL, INCIDENTAL
O CONSIGUIENTE (INCLUYENDO LOS GASTOS DE LABOR PARA REPARAR, REEMPLAZAR, INSTALAR O DESMONTAR ESTE PRODUCTO), YA SEA EL
RESULTADO DEL INCUMPLIMIENTO DE CUALQUIER GARANTÍA EXPRESA O IMPLÍCITA, INCUMPLIMIENTO DE CONTRATO, AGRAVIO O DE OTRA MANERA.
DELTA FAUCET COMPANY NO SE RESPONSABILIZAR POR CUALQUIER DAÑO AL GRIFO QUE RESULTE DEL DESGASTE RAZONABLE, USO EN EL EXTERIOR
DE LA PROPIEDAD, USO INDEBIDO (INCLUYENDO EL USO DEL PRODUCTO PARA UNA APLICACIÓN INDEBIDA), AGUA HELADA, ABUSO, NEGLIGENCIA O
INSTALACIÓN O MANTENIMIENTO INADECUADO O INCORRECTO, INCLUYENDO EL NO SEGUIR LAS INSTRUCCIONES CORRESPONDIENTES PARA EL
CUIDADO, LA LIMPIEZA Y EL MANTENIMIENTO. Aviso para los residentes del estado de New Jersey: Las disposiciones de este documento tienen la intención de
aplicarse en la máxima medida permitida por las leyes del estado de New Jersey.
Derechos adicionales. Esta garantía le otorga derechos legales específicos y también puede tener otros derechos que varían de estado/provincia a estado/provincia.
Esta es la garantía escrita exclusiva de Delta Faucet Company y la garantía no es transferible.
Si tiene preguntas o dudas con respecto a nuestra garantía, por favor comuníquese con nosotros como se indica anteriormente o consulte nuestras Preguntas Frecuentes
Warranty FAQs en www.deltafaucet.com.
Garantía Limitada en las Llaves de Agua de Delta
®
© 2020 Delta Faucet Company
107528 Rev. D
1
Instalación de la plomería MultiChoice
®
(Cuando su producto lo requiere)
3
CIERRE LOS SUMINISTROS DE AGUA.
Considere el tipo y el grosor de su pared
terminada antes de colocar su placa trasera
de acoplamiento de las tuberías. Instale la
pieza (1) de manera que la superficie de la
pared terminada quede al ras con el frente
del protector de yeso (2) ± 3/8". Nota: Para
con los modelos de las paradas (3), el
protector del yeso debe ser el rubor
A.
B.
rasante o secundario el 3/8a la pared
acabada. Instale la pieza usando los dos
agujeros de instalación del acoplamiento
(4) en el soporte. Cuando esté haciendo la
instalación, asegúrese que la palabra
“UP” (5) quede arriba de la válvula.
1
2
5
4
4
1
2
3
La distancia (1) del larguerillo (2) a la
parte delantera del protector de yeso es
de 2.8" (71 mm).
Si se utiliza una pared delgada,
asegúrese de tener el protector de yeso
por detrás de la pared, de lo contrario, la
pared siempre debe estar al ras con la parte
delantera del protector de yeso. Consulte
las instrucciones en la bolsa para el montaje
en pared delgada.
107528 Rev. D
4
Conecte el cuerpo de la válvula a los sumin-
istros de agua usando los accesorios apro-
piados para el tipo de su válvula (tubería de
cobre, hierro o Pex). Nota: (1) es la entrada
del agua fría y el (2) es la entrada del agua
caliente. Si no va a usar alguna de las dos
entradas de agua, séllela con un tapón
de tubería.
Si está hacienda una instalación dorso
con dorso o a la inversa (caliente en la
derecha y fría en la izquierda) instale el
cuerpo de la válvula como se describe
arriba, pero coloque al inverso las líneas
de suministro de agua. Nota: (1) es
la entrada de agua caliente (2) es la
entrada del agua fría.
Tubería de
Cobre
Hierro
Pex
D.
Quite el capuchón (1).
AVISO: Evite soldar a altas temperaturas. Los
componentes de las tuberías detrás de las
paredes podrían dañarse.
Sea seguro que las válvulas apagadas
(2) están quitadas de la versión con las
paradas antes de soldar. (no instale las
válvulas apagadas antes de soldar.)
1
2
C.
1
2
1
2
1
2
107528 Rev. D
5
Instalación
Conecte la salida de arriba (1) a la tubería de
la regadera con los accesorios apropiados.
Conecte la salida de abajo (2) a la tubería
del surtidor de la bañera con los accesorios
apropiados. La tubería (3) entre el cuerpo de
la válvula y el de la bañera debe ser de un
mínimo de 1/2" (13 mm) de tubería de cobre
ó 1/2" (13 mm) de tubería de hierro en caída
recta no menos de 8" (203 mm) pero no más
de 18" (457 mm) de largo a la entrerrosca del
surtidor de la bañera y con sólo un codo de 90
grados, de tubería de hierro o cobre. No use la
tubería PEX como tubería entre la válvula y
el surtidor de la bañera.
E.
1
2
3
F.
PRUEBA DE PRESIÓN Y
LIMPIEZA DE LA INSTALACIÓN
1
1
3
2
2
3
Para enjuagar el sistema de desechos,
retire la tuerca tapa
(1).
Prepare el área para rociar con agua.
Lentamente abra los suministros de
agua para depurar el sistema por 30
segundos.
Después de enjuagar, instale el
cartucho y la tuerca tapa.
Gire la espiga del cartucho en sentido
antihorario hasta que pare.
PARA LOS MODELOS CON TOPES, instale los topes, pero
déjelos en posición completamente abierta. Instale los topes de la
siguiente manera:
Enrosque la tuerca (2) en la espiga (3) como se muestra. A
continuación, presione el ensamble de la espiga y la tuerca en
la unidad y apriételo con una herramienta de tubo largo con
entrada de 6 puntos de 3/8”. Con un destornillador de cabeza
plana, ajuste la espiga en el sentido de las agujas del reloj para
cerrarla y en el sentido contrario a las agujas del reloj para
abrirla.
Tape el surtidor de la bañera y/o la salida o salidas de agua de
la regadera con el accesorio apropiado para su tubería.
Examine si hay fugas.
Después de hacer la prueba de fugas o filtraciones de agua,
cierre la válvula girando la espiga del cartucho completamente
en el sentido de las agujas del reloj.
107528 Rev. D
2
Instalación del Cartucho
A.
Cierre los suministros de agua. Quite la
la tuerca tapa (1) y la tapa de prueba (2). Si
no es para instalar en pared delgada, puede
quitar el protector (3) de yeso completo. Si
la pantalla (4) está en lugar, quite antes de
instalar el cartucho.
Gire el cartucho de la válvula (1) de forma que
las palabras "HOTTER COLDER" estén en la
parte superior. Inserte el cartucho en el cuerpo
de la tubería preliminar.
Una ligera capa de grasa de plomería aplicada
a las juntas tóricas puede ayudar en el
montaje. Asegúrese de que el dentado en el
cuerpo está totalmente encajado en la muesca
en el cuerpo de bronce (4).
Instalación de Espalda a Espalda
En las instalaciones dorso con dorso o al
reverso (caliente en la derecha y fría en
la izquierda) introduzca el cartucho con la
inscripción “hot side” a la derecha. Si usted
no está instalando al reverso o dorso con
dorso omita este paso y continúe con el
paso 2C.
Deslice la tuerca tapa (1) sobre el cartucho
y enrosque en el cuerpo de la válvula.
Apriete a mano bien.
6
Instalación Normal (No serequerá cambios)
Instalación
Invertido
Fría
Caliente
1
2
4
3
C.
1
B.
1
3
2
4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Delta Faucet T13220-SS Manuel utilisateur

Catégorie
Articles sanitaires
Taper
Manuel utilisateur