2
EN
Thank you for purchasing the hands free kit HFX-7000MW!
This intercom system uses 2-wire installation and allows you to identify and communicate
with callers at the door, from the security and convenience of any room in your home or
office.
Visitors activate the system by pressing a call pad on the external unit, which sounds a
doorbell chime as well as turning on the inside "hands free video monitor".
A two-way intercom then lets you speak with visitors after first visually identifying them.
By installing and configuring the COMELIT App on smartphone/tablet it is possible to
answer video door entry calls from a local and remote network (or mobile network); in
addition it is possible to make a Self-ignition on cameras/entrance panels and send
commands to actuator modules.
HFX-7000MW kit consists of a hands free monitor station and an external unit.
This kit is capable of expanding up to a total of 4 indoor monitors and 4 external units.
3
EN
1. Contents of the package ......................................................... 4
2. Parts identification ................................................................... 5
2.1 EX-DSME EXTERNAL UNIT ........................................................................................5
2.2 EX-7000HW MONITOR ...............................................................................................6
2.2.1 Capacitive-touch key description ...................................................................7
2.2.2 Indicator LED description ...............................................................................7
2.3 1209/4 BUS POWER SUPPLY ...................................................................................8
2.4 PARTS IDENTIFICATION FOR EXPANSION ...............................................................8
2.4.1 Video door expander 1405 .............................................................................8
3. System installation ................................................................... 9
3.1 OPERATING DISTANCES AND SYSTEM LAYOUT ....................................................9
3.1.1 Single-User Kit HFX-7000MW .......................................................................9
3.1.2 Maximum Expansion Monitors in Daisy Chain connection ...........................9
3.1.3 Full System Expansion Diagram ...................................................................10
BASIC SINGLE-USER KIT
STANDARD INSTALLATION .......................................................................11
EXPANDED SINGLE-USER KIT
MAXIMUM EXPANSION IN DAISY CHAIN CONNECTION ........................12
EXPANDED SINGLE-USER KIT
MAXIMUM EXPANSION .............................................................................. 13
MULTI-USERS EXPANSION
TWO-USERS EXPANSION .......................................................................... 14
MULTI-USERS EXPANSION
FOUR-USERS EXPANSION ........................................................................ 15
FULL MULTI-USERS EXPANSION
FOUR-USERS EXPANSION WITH FOUR EXTERNAL UNIT ....................... 16
TV INTERFACE (ART. 1257) CONNECTION ................................................17
BASIC SINGLE-USER KIT
BASIC SINGLE-USER KIT
ADDITIONAL RELAY MODULE (ART. 1256) CONNECTION .......................18
BASIC SINGLE-USER KIT
FULL MULTI-USERS EXPANSION
FOUR-USERS EXPANSION WITH FOUR EXTERNAL UNIT AND CCTV
CAMERA INTERFACE (ART. 1409) ....................................................... 20
3.2 ASSEMBLY MINI HANDSFREE ART. EX-7000HW INTERNAL UNIT ........................21
3.2.1 Removing monitor .......................................................................................22
3.2.2 Removing the terminal / inserting the terminal ...........................................22
3.3 INSTALLATION OF EXTERNAL UNIT ART. EX-DSME ...............................................23
3.3.1 How to change the nameplate of the external unit art. EX-DSME ...............24
4. Additional features programming ........................................... 25
4.1 ADDRESSING ART. EX-7000HW BY MEANS OF DIP-SWITCH ................................25
4.2 CONFIGURATION CAPACITIVE-TOUCH KEYS ART. EX-7000HW............................25
4.2.1 Preset functions ...........................................................................................25
Legend ..................................................................................................................25
4.2.2 Quick programming ......................................................................................26
4.2.3 Special key programming .............................................................................26
4.2.3.1 HOW TO PROGRAM THE ACTUATOR FUNCTION ........................26
4.2.3.2 HOW TO PROGRAM THE INTERCOM FUNCTION ........................ 27
4.2.3.3 HOW TO PROGRAM THE PAGING FUNCTION .............................27
4.2.3.4 HOW TO PROGRAM THE SELF-IGNITION FUNCTION .................28
4.2.3.5 HOW TO PROGRAM THE DOCTOR MODE ...................................28
4.3 RESET PROGRAMMING ART. EX-7000HW ..............................................................29
4.4 RANGE PROGRAMMING ART. EX-7000HW .............................................................29
4.5 MONITOR RINGTONE SELECTION ART. EX-7000HW .............................................30
4.6 CONFIGURATION EX-DSME ......................................................................................30
4.6.1 External unit addressing ...............................................................................30
4.6.2 Function programming .................................................................................30
4.6.3 Call address programming for 2/4 users ......................................................31
4.6.4 User code ..................................................................................................... 31
4.7 ACTUATOR RELAY MODULE ART. 1256 ...................................................................32
4.7.1 Parts description ..........................................................................................32
4.7.2 Functions ...................................................................................................... 32
4.8 TV INTERFACE ART. 1257 ..........................................................................................33
4.8.1 Parts description ..........................................................................................33
4.8.2 Functions ...................................................................................................... 33
4.9 CCTV CAMERA INTERFACE ART. 1409 ....................................................................34
4.9.1 Parts description ..........................................................................................34
4.9.2 Operation .....................................................................................................34
4.9.2.1 PROGRAMMING THE NUMBER OF CAMERAS CONNECTED .....34
4.9.2.2 FUNCTION 1: GENERIC ACTUATOR MODE ..................................34
4.9.2.3 FUNCTION 2: ACTUATOR WITH CODE MODE .............................. 35
4.9.2.4 COMPATIBILITY TABLE ..................................................................35
5. System function........................................................................ 36
5.1 PERFORMING CALLS ................................................................................................36
5.1.1 How to call from the external unit ................................................................36
5.1.2 How to answer a call from an internal unit ...................................................36
5.1.3 How to transmit a call to the other internal units ..........................................36
5.1.4 How to answer a call from an internal unit ...................................................36
5.2 PAGING CALL .............................................................................................................37
5.2.1 How to initiate a paging call .........................................................................37
5.2.2 How to answer a paging call ........................................................................37
5.3 ACTIVATION HANDS-FREE MODE ............................................................................37
5.4 LOCK RELEASE FUNCTION ......................................................................................37
5.5 SELF-IGNITION FUNCTION .......................................................................................37
5.5.1 How to display on the monitor the image transmitted from the CCTV camera
38
5.6 ACTIVATION DOCTOR MODE ....................................................................................38
5.7 ACTIVATION PRIVACY MODE ....................................................................................38
6. Navigation mode ...................................................................... 38
7. Device functions ....................................................................... 39
7.1 VIDEO MEMORY.........................................................................................................39
7.2 VIDEO MESSAGES .....................................................................................................39
7.3 WI-FI ............................................................................................................................39
Wi-Fi connection status - Key to symbols .............................................................39
Signal strength ......................................................................................................39
7.3.1 Wi-Fi setup via the monitor ..........................................................................39
PROCEDURE VIA WPS...............................................................................39
MANUAL PROCEDURE ..............................................................................39
7.3.2 Wi-Fi setup via the COMELIT app ................................................................ 39
7.4 SETUP .........................................................................................................................40
7.4.1 Wi-Fi reporting unconnected .......................................................................40
7.4.2 App registration enable ................................................................................40
7.4.3 Date and time settings .................................................................................40
7.4.4 Language .....................................................................................................40
7.4.5 Information ...................................................................................................40
7.4.6 Reset ............................................................................................................40
7.4.7 Update product ............................................................................................40
8. Technical specification ............................................................ 41
8.1 EX-7000HW MAIN MONTOR .....................................................................................41
8.2 EX-DSME EXTERNAL UNIT ........................................................................................41
8.3 1209/4 BUS POWER SUPPLY ...................................................................................41
8.4 ACTUATOR RELAY MODULE ART. 1256 ...................................................................41
8.5 TV INTERFACE ART. 1257 ..........................................................................................41
8.6 REMOTE CAMERA MODULE ART. 1409 ...................................................................41
8.7 DOOR EXPANDER ART. 1405 ...................................................................................41
9. Appendix ................................................................................... 42
9.1 WARNING ...................................................................................................................42
9.2 IMPORTANT SAFETY INSTRUCTIONS ......................................................................42
9.3 FCC CLASS B NOTICE ...............................................................................................43
9.4 GENERAL PRODUCT WARRANTY: ...........................................................................43
Contents
4
EN
1. Contents of the package
monitor backplate
×1 ×1
×4 ×4
screws
dry wall
anchors
EX-7000HW - Monitor
EX-7000HW 1209/4EX-DSME
PUSH HERE
HFX-7000MW Kit
Replaceable call buttons
for 2 usersfor 1 user for 4 users
screwsexternal unit
×3 ×3
dry wall
anchors
×1
×1 ×1 ×1
PUSH HERE
PUSH HERE
EX-DSME - External unit
screwspower supply
×1 ×2
1209/4 - BUS Power supply
Passion.Technology.Design.
EN
QUICK
REFERENCE
GUIDE
EN FR ES
Quick reference Guide for
Single-User Kit HFX-7000M
also available in
French and Spanish
Technical manual
The “Smart registration” manual will help during the first installation
of Comelit app on smartphone / tablet.
“Smart registration” manual and “Comelit app” manual are
available to download from the website pro.comelitgroup.com
5
EN
3.79 in
7.72 in
1.06 in
PUSH HERE
8.
9.
10.
11.
12.
13.
14.
15.
16.
1.
2.
3.
4.
5.
6.
7.
PUSH HERE
1. Die-cast aluminium cover
2. Camera lighting LED (Can be disabled by setting DIP 7 to ON, see
page 30 "4.6.2 Function programming" )
3. Wide-angle colour camera
4. Loudspeaker
5. Indicator LED
call sent / lock-release enabled
audio enabled / system engaged
6. Call button 1 user
For instructions on replacing the nameplate, see page 24
“3.3.1 How to change the nameplate of the external unit art. EX-
DSME” .
For instructions on enabling the buttons for 2/4 users, see page
31 “4.6.3 Call address programming for 2/4 users” .
7. Microphone
8. Terminal block M1
LL bus line connection
RTE timed local lock-release input
COM common input for RTE and DO contacts
DO door open indication input
9. PR programming input/output switch
10. CNF programming confirmation switch
11. Loudspeaker volume control
12. Audio balance (Factory default do not touch)
13. Terminal block M2
SE- SE+ connection for electric door lock
NC relay normally closed contact
NO relay normally open contact
C relay common contact
14. JP1 enable RC network for door lock filter on relay contacts
ON CONTACTS C. NO. ON CONTACTS C. NC.
DISABLED: CLEAN CONTACT
15. DIP SWITCH for function programming
16. Microphone volume control
2. Parts identification
2.1 EX-DSME EXTERNAL UNIT
6
EN
4.52 in 0.83 in
6.29 in
2.2 EX-7000HW MONITOR
3.
5.
4.
1.
2.
6.
7.
8.
9.
10.
12.
11.
13.
1. Brightness control
f To increase the value, turn clockwise
2. Loudspeaker volume control
f To increase the value, turn clockwise
3. Call volume adjustment (high - medium - low)
4. 4.3” colour LCD screen
5. Speaker and audio activation key / Paging call key
6. Capacitive-touch keys
7. S1
Micro-switches for user code setting
8. S2
Micro-switches for programming keys and functions
DIP 1-2-3-4 Keys function programming
DIP 5-6 Access to programming
DIP 7 Power supply voltage management (Default ON - Do not
change!)
DIP 8 (not used)
9.10. Factory setting - Do not change!
11. CV 5 Jumper for video closure
12. Pin for securing terminal block
13. S3 Microswitches:
DIP 1 operating mode (Default ON - Do not change!)
DIP 2 (not used)
Terminal block for system connection:
LL BUS line connection terminals
CFP1 CFP2 Outside door call input
7
EN
2.2.1 Capacitive-touch key description
SPEAKER AND AUDIO ACTIVATION KEY / PAGING CALL KEY / HANDS-FREE MODE ACTIVATION KEY
Answer call
Can be used to activate a conversation with the external unit or to end a conversation.
Paging call
Internal paging function: can be used to make a paging call to the internal units with the same user code.
General paging to another user code: can be used to make a paging call to the internal units with another user code.
Hands-Free mode
On receipt of a call the audio will be activated automatically.
LOCK-RELEASE KEY
can be used to activate the lock-release relay
ACTUATOR [programmable]
Generic actuator function: can be used to activate the relay for a generic actuator installed within the system.
Coded actuator function: can be used to activate the relay for a specific actuator installed within the system.
SELF-IGNITION [programmable]
Can be used to receive images from the main external unit cameras (press the key again to cycle through several external unit
[programmable]
DOCTOR MODE [programmable]
can be used to enable automatic activation of the lock-release in response to a call from the external unit.
NAVIGATING MENU: up, down, right and left
CONFIRM A SELECTION, SELECT / DESELECT AN OPTION
Quick access to the VIDEO MESSAGES SECTION
MENU / ON-OFF DISPLAY / RETURN
PRIVACY KEY
Privacy mode
Can be used to enable or to disable the ringtone for calls from the external unit and paging.
2.2.2 Indicator LED description
FLASHING LED: incoming call
STEADY LED (WITH CALL): In communication
STEADY LED (IDLE): Hands-Free mode enabled
FLASHING LED: Incoming call
FLASHING LED (SLOWLY): door open
1 FLASH AFTER PRESSING: door opening confirmation
1 FLASH AFTER PROG.: Confirm “Key programming executed”
STEADY LED: Privacy mode active
STEADY AND FLASHING LED (3 every 5 s.): Doctor and Privacy active
OFF AND FLASHING LED (3 every 5 s.): Doctor mode active
4 FLASHES: The called device is busy
FLASHING LED: User notification present
See page 36 “5. System function”
8
EN
2.3 1209/4 BUS POWER SUPPLY
1. LM LM Art. 1209/4 connection
2. LS | LS additional external unit connection
LP | LP main external unit connection
1. LP LP external unit connection
2. L1 | L1 monitor connection 1
L2 | L2 monitor connection 2
L3 | L3 monitor connection 3
L4 | L4 monitor connection 4
3. Video closing jumpers
(REMOVE WHEN LINE IS USED)
4. L
N mains power input 110-240
V~
1.
2.
3.55 in
1.42 in 2.28 in
50-60Hz
OUTPUT/SORTIE 34V 0.5A 2A 1'on/5'o
ta=40°C
110V-240V
1.4A
L
N
L4
L4
L3
L3
INPUT/D'ENTREE
Dopo un cortocircuito,per ripristinare l'apparecchio,
interrompere l'alimentazione per circa 1 minuto.
To reset the operation after a short circuit,cut o mains
voltage for about 1 minute.
Apres un court circuit, pour remettre en fonction l'appareil,
interrompre l'alimentation pendant environs une minute.
L2L2L1L1
LP
LP
C US
R
Art.1209/4
1.
2.
3.
4.
2.4 PARTS IDENTIFICATION FOR EXPANSION
ADDITIONAL INTERNAL UNIT
EX-7000H
EX-7000H
The art. EX-7000H is the additional internal unit for Single-User Kits.
(For further information see the respective manual).
ADDITIONAL EXTERNAL UNIT
EX-DSQE
+
1405
EX-DSME
The art. EX-DSQE is the additional external unit and contains the
external unit art. EX-DSME (See "EX-DSME" on page 5 for further
information) and the Video door expander art. 1405 (See point 2.4.1 for
further information).
2.4.1 Video door expander 1405
4.17 in 3.52 in
2.44 in
9
EN
A
B
C
1209/4
EX-7000H
expansion monitor
EX-7000H
expansion monitor
EX-7000H
expansion monitor
EX-DSME
HFX-7000MW
EX-7000HW
3.1.2 Maximum Expansion Monitors in Daisy Chain connection3.1.1 Single-User Kit HFX-7000MW
A
B
C
1209/4
EX-DSME
HFX-7000MW
EX-7000HW
3. System installation
Wire Assignment Wire Assignment Wire Type
A max B max C max
SINGLE PAIR CABLE
CAT5
24AWG
1,115 feet
(340 m)
557 feet
(170 m)
557 feet
(170 m)
DOUBLE PAIR
CABLE
CAT5
24AWG
1,312 feet
(400 m)
656 feet
(200 m)
656 feet
(200 m)
MULTI PAIR CABLE
FOLLOW THE COLORS
SHOWN IN THE DIAGRAM!
GREEN
ORANGE
BLU
GREEN / WHITE
ORANGE / WHITE
BLU / WHITE
BROWN / WHITE
BROWN
CAT5
24AWG
1,312 feet
(400 m)
656 feet
(200 m)
656 feet
(200 m)
NON-BRAIDED
CABLE
AWG22
1,115 feet
(340 m)
557 feet
(170 m)
557 feet
(170 m)
NON-BRAIDED
CABLE
AWG18
1,312 feet
(400 m)
656 feet
(200 m)
656 feet
(200 m)
3.1 OPERATING DISTANCES AND SYSTEM LAYOUT
Maximum 2 monitors
per output
10
EN
1209/4
EX-7000H
expansion monitor
EX-7000H
expansion monitor
EX-7000H
expansion monitor
1405 14051405
EX-DSME EX-DSME EX-DSME EX-DSME
A
B
C
HFX-7000MW
EX-DSQE
expansion external unit
EX-DSQE
expansion external unit
EX-DSQE
expansion external unit
EX-7000HW
3.1.3 Full System Expansion Diagram
EX-DSQE
+
1405
EX-DSME
NOTE: This system is capable to expanding up to 4 external units and 4 internal units. For alternative application please consult
our technical support engineer first.
At the first connection on the riser, the internal units automatically acquire theirs sub-addresses.
The LEDs
and flash simultaneously for some seconds. After the procedure the LEDs will turn off.
The art. EX-DSQE is the additional external unit for Single-User Kits and contains the external unit art. EX-DSME and the Video
door expander art. 1405.
11
EN
Basic single-user kit
STANDARD INSTALLATION
routerComelit app
EX-7000HW
HFX-7000MW
C
F
P
LL
C
F
P
1
2
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
34 Vdc
S1
A
1209/4
L1 L1 L2 L2
L
N
110-240V
LP LP L3 L3 L4 L4
ON
85 764321
LEAVE DEFAULT SETTING
Local lock release button
12
EN
Expanded single-user kit
CV5
Video Closing Jumper
MAXIMUM EXPANSION IN DAISY CHAIN CONNECTION
C
F
P
LL
C
F
P
1
2
1209/4
L1 L1 L2 L2
L
N
110-240V
LP LP L3 L3 L4 L4
C
F
P
LL
C
F
P
1
2
ON
85 764321
C
F
P
LL
C
F
P
1
2
EX-7000H
EX-7000H
EX-7000H
S1
A
C
F
P
LL
C
F
P
1
2
REMOVE WHEN LINE IS USED
REMOVE CV5
REMOVE CV5
LEAVE DEFAULT SETTING
ON
85 764321
S1
A
LEAVE DEFAULT SETTING
ON
85 764321
S1
A
LEAVE DEFAULT SETTING
ON
85 764321
S1
A
LEAVE DEFAULT SETTING
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
HFX-7000MW
routerComelit app
EX-7000HW
Local lock release button
13
EN
Expanded single-user kit
MAXIMUM EXPANSION
0 1 2 3
C
F
P
LL
C
F
P
1
2
HFX-7000MW
1209/4
L1 L1 L2 L2
L
N
LP LP L3 L3 L4 L4
C
F
P
LL
C
F
P
1
2
EX-7000H
C
F
P
LL
C
F
P
1
2
EX-7000H
C
F
P
LL
C
F
P
1
2
EX-7000H
1405
L
M
L
M
L
S
L
S
L
P
L
P
1405
L
M
L
M
L
S
L
S
L
P
L
P
1405
L
M
L
M
L
S
L
S
L
P
L
P
THESE DEVICES
MUST BE STORED TOGETHER
MAXIMUN CABLE LENGHT FOR 1405: 3 feet
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
ON
85 764321
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
ON
85 764321
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
ON
85 764321
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
ON
85 764321
REMOVE WHEN LINE IS USED
SET THE ADDRESS SET THE ADDRESS SET THE ADDRESS
LEAVE DEFAULT SETTING
ON
85 764321
S1
A
LEAVE DEFAULT SETTING
ON
85 764321
S1
A
LEAVE DEFAULT SETTING
ON
85 764321
S1
A
LEAVE DEFAULT SETTING
ON
85 764321
S1
A
LEAVE DEFAULT SETTING
EX-DSQE
+
1405
EX-DSME
EXTERNAL UNIT ADDRESSING
DIP 1 DIP 2 DIP 3 CODE
0 0 0
0 (default)
1 0 0
1
0 1 0
2
0 0 1
3
The addresses must be consecutive!
correct: 0,1,2,3 / incorrect: 0,1,3
Local lock release button
14
EN
HFX-7000MW
ON
85 764321
C
F
P
LL
C
F
P
1
2
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
S1
A
S1
A
1209/4
L1 L1 L2 L2
L
N
110-240V
LP LP L3 L3 L4 L4
ON
85 764321
C
F
P
LL
C
F
P
1
2
EX-7000HW EX-7000HW
REMOVE WHEN LINE IS USED
SET
THE ADDRESSLEAVE DEFAULT SETTING
Comelit app
router
Comelit app
router
1 2
Multi-users expansion
TWO-USERS EXPANSION
Local lock release button.
For programming see page 31 "4.6.3 Call address programming for 2/4 users"
15
EN
HFX-7000MW
C
F
P
LL
C
F
P
1
2
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
1209/4
L1 L1 L2 L2
L
N
110-240V
LP LP L3 L3 L4 L4
ON
85 764321
C
F
P
LL
C
F
P
1
2
ON
85 764321
C
F
P
LL
C
F
P
1
2
ON
85 764321
C
F
P
LL
C
F
P
1
2
3
4
#
SET THE ADDRESS SET THE ADDRESS SET THE ADDRESS
REMOVE WHEN LINE IS USED
EX-7000HW
EX-7000HW EX-7000HW EX-7000HW
2
Comelit app
router
Comelit app
router
Comelit app
router
Comelit app
router
ON
85 764321
S1
A
S1
A
LEAVE DEFAULT SETTING
1
Multi-users expansion
FOUR-USERS EXPANSION
Local lock release button.
For programming see page 31 "4.6.3 Call address programming for 2/4 users"
16
EN
0 1 2 3
C
F
P
LL
C
F
P
1
2
HFX-7000MW
1209/4
L1 L1 L2 L2
L
N
110-240V
LP LP L3 L3 L4 L4
ON
85 764321
C
F
P
LL
C
F
P
1
2
ON
85 764321
C
F
P
LL
C
F
P
1
2
ON
85 764321
C
F
P
LL
C
F
P
1
2
1405
L
M
L
M
L
S
L
S
L
P
L
P
1405
L
M
L
M
L
S
L
S
L
P
L
P
1405
L
M
L
M
L
S
L
S
L
P
L
P
THESE DEVICES
MUST BE STORED
TOGETHER
MAXIMUN CABLE LENGHT FOR 1405: 3 feet
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
ON
85 764321
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
ON
85 764321
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
ON
85 764321
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
ON
85 764321
REMOVE WHEN LINE IS USED
2
# # # #
SET THE ADDRESS SET THE ADDRESS SET THE ADDRESS
LEAVE DEFAULT SETTING
SET THE ADDRESS
SET THE ADDRESS SET THE ADDRESS
EX-7000HW
EX-7000HW EX-7000HW EX-7000HW
3 4
ON
85 764321
S1
A
S1
A
S1
A
S1
A
LEAVE DEFAULT SETTING
1
Local lock release button.
For programming, see 31 "4.6.3 Call address programming for 2/4 users"
EXTERNAL UNIT ADDRESSING
DIP 1 DIP 2 DIP 3 CODE
0 0 0
0 (default)
1 0 0
1
0 1 0
2
0 0 1
3
The addresses must be consecutive!
correct: 0,1,2,3 / incorrect: 0,1,3
Full multi-users expansion
FOUR-USERS EXPANSION WITH FOUR EXTERNAL UNIT
EX-DSQE
+
1405
EX-DSME
17
EN
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
1209/4
L1 L1 L2 L2
L
N
110-240V
LP LP L3 L3 L4 L4
~
-
L
OUT
G
V
1257
~
L
+
N
D
SH
IND 1
IND 2
1234 675 8
ON
ON
85 764321
JP4
P
T
B/N
JP2
B/NC
C
JP1
12V~
1200UL
120V~
C
F
P
LL
C
F
P
1
2
CABLEEQUIPMENT
CP2N
SINGLE ADDRESS MODE
HFX-7000MW
REMOVE CV5
ON
85 764321
S1
A
LEAVE DEFAULT SETTING
S1
S2
JP3
MOVE JP3LEAVE DEFAULT SETTING
EX-7000HW
Comelit app
router
Local lock release button.
For further information see page 33 "4.8 TV INTERFACE ART. 1257"
Basic single-user kit
TV INTERFACE (Art. 1257) CONNECTION
18
EN
HFX-7000MW
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
C
N
O
C
N
L L
~
-
~
+
L
OUT
L
IN
L
IN
L
OUT
LM
LM
1214/2C
1256
12/24V
AC/DC
12V~
1200UL
120V~
JP2
2 1
12
JP3
JP4
2
1
C
F
P
LL
C
F
P
1
2
1209/4
L1 L1 L2 L2
L
N
110-240V
LP LP L3 L3 L4 L4
EX-7000HW
Comelit app
router
ON
85 764321
S1
A
LEAVE DEFAULT SETTING
For further information see page 32 "4.7 Actuator relay module Art. 1256"
Local lock release button
Basic single-user kit
ADDITIONAL RELAY MODULE (Art. 1256) CONNECTION
19
EN
HFX-7000MW
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
1409
G
N
DA
N
I
3
V S
32
SV
2
S
11
V
+
-
~ ~
LLL
OUT
L
OUT
IN IN
120V~
12V~
1200UL
C
F
P
LL
C
F
P
1
2
1209/4
L1 L1 L2 L2
L
N
110-240V
LP LP L3 L3 L4 L4
1234 675 8
ON
EX-7000HW
Comelit app
router
ON
85 764321
S1
A
LEAVE DEFAULT SETTING
Local lock release button
For further information see page 34 "4.9 CCTV camera interface ART. 1409"
Basic single-user kit
CCTV CAMERA INTERFACE (Art. 1409) CONNECTION
20
EN
1409
G
N
DA
N
I
3
V S
32
SV
2
S
11
V
+
-
~ ~
LLL
OUT
L
OUT
IN IN
120V~
12V~
1200UL
C
F
P
LL
C
F
P
1
2
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
1209/4
L1 L1 L2 L2
L
N
110-240V
LP LP L3 L3 L4 L4
ON
85 764321
C
F
P
LL
C
F
P
1
2
ON
85 764321
C
F
P
LL
C
F
P
1
2
ON
85 764321
C
F
P
LL
C
F
P
1
2
1405
L
M
L
M
L
S
L
S
L
P
L
P
ON
85 764321
1405
L
M
L
M
L
S
L
S
L
P
L
P
1405
L
M
L
M
L
S
L
S
L
P
L
P
THESE DEVICES
MUST BE STORED
TOGETHER
MAXIMUN CABLE LENGHT FOR 1405: 3 feet
#
0
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
ON
85 764321
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
ON
85 764321
LL
O
D
E
T
R
NO
SE
-
SE
+
NC C
M
O
C
EX-DSME
ON
85 764321
#
#
#
1
2
3
REMOVE WHEN LINE IS USED
1234 675 8
ON
SET THE ADDRESS
SET THE ADDRESS
SET THE ADDRESS
SET THE ADDRESS
LEAVE DEFAULT SETTING
1
EX-7000HW
EX-7000HW EX-7000HW EX-7000HW
2
3 4
HFX-7000MW
ON
85 764321
S1
A
S1
A
SET THE ADDRESS
S1
A
SET THE ADDRESS
S1
A
LEAVE DEFAULT SETTING
EX-DSQE
+
1405
EX-DSME
Full multi-users expansion
FOUR-USERS EXPANSION WITH FOUR EXTERNAL UNIT and CCTV CAMERA INTERFACE (Art. 1409)
EXTERNAL UNIT ADDRESSING
DIP 1 DIP 2 DIP 3 CODE
0 0 0
0 (default)
1 0 0
1
0 1 0
2
0 0 1
3
The addresses must be consecutive!
correct: 0,1,2,3 / incorrect: 0,1,3
Local lock release button.
For programming, see page 31 "4.6.3 Call address programming for 2/4 users"
For further information see page 34 "4.9 CCTV camera interface ART. 1409"
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128

Comelit HFX-7000MW Technical Manual

Taper
Technical Manual

dans d''autres langues