Sera mic pH Controller Information For Use

Taper
Information For Use
12
®
Mikroprozessorgesteuerte
pH-Mess- und Regelanlage
für Süß- und Meerwasseraquarien
Microprocessor controlled
pH measuring and
monitoring device
for fresh and salt water aquariums
Dispositif de mesure
et de régulation du pH
à microprocesseurs
pour aquariums d’eau douce
et d’eau de mer
D
US
F
seramic pH Controller
seramic pH Controller
111111111111111111111131
38/02INT
2
DGebrauchsinformation 5
US Information for use 13
FInformation mode d’emploi 21
NL Gebruikersinformatie 29
IInformazioni per l’uso 37
EInformación para el usuario 45
PInstruções para utilização 53
SProduktinformation 61
FI Käyttöohje 69
DK Brugsinformation 77
GR ÃÃååííééêêYYòò DDëëççññïïööïïññßßååòò85
SI Navodilo za uporabo 93
HR Upute za upotrebu 101
HHasználati információ 109
PL Informacje o zastosowaniu 117
CZ InformaËní popis 125
TR Kullanım bilgileri 133
RUS ÈÈííññòòddóóêêööèèÿÿ ïïîî ïïddèèììååííååííèèpp141
3
1
2
Technische Änderungen
und Irrtum vorbehalten
Subject to technical
alterations and errors
Sous réserve de modifications
techniques et d’erreurs
4
12 h
3.1
3.4
3.2
3.3
3.5
CO2
3.6
3.8 3.9 3.10
3.7
3.7
3.3
3.3
3.5 3.5
3.7
45
67
8910
3
5
Herzlichen Glückwunsch zum Kauf dieses hochwertigen
seramic pH Controllers.
1. Anwendungsmöglichkeiten
Der mikroprozessorgesteuerte seramic pH Controller
regelt die pH-Wert-Einstellung im Süß- und Meerwas-
seraquarium. Der seramic pH Controller misst über die
angeschlossene pH-Elektrode den pH-Wert und reguliert
über das angeschlossene Dosiergerät, Magnetventil oder
Pumpe den pH-Wert auf die eingestellte Sollgröße.
Typische Anwendungen der seramic sind die Dosie-
rung von Kohlensäure im Süßwasseraquarium oder der
Betrieb eines Kalkreaktors im Meerwasseraquarium.
1.1 Regelung des pH-Wertes nach unten durch Zugabe
von CO2
1.1.1 Einsatz als CO2-Düngeanlage (1)
Die häufigste Anwendung der seramic in Süßwasser-
aquarien ist die Düngung der Aquarienpflanzen durch
den gezielten, gesteuerten Eintrag von CO2.
Die Dosierung des CO2erfolgt über ein hochwertiges
Magnetventil, das im Lieferumfang enthalten ist. Das
Magnetventil wird über den externen Stecker, der sein
Signal von der seramic bekommt, gesteuert. Der
gewünschte pH-Wert des Wassers wird mittels der
Tastatur auf der seramic präzise eingestellt. Da CO2
bzw. Kohlensäure sauer reagiert, wird durch die sera-
mic bei dieser Anordnung der pH-Wert abgesenkt.
Wenn der gewünschte Wert erreicht wird, schließt die
seramic über den externen Stecker das Magnetventil.
1.1.2 Einsatz als Steuergerät für einen Kalkreaktor (2)
Zur Steuerung eines Kalkreaktors muss die sera pH-
Elektrode in der vorgesehenen Öffnung des Kalkreaktors
wasserdicht befestigt werden. Die CO2-Versorgung des
Calciumreaktors wird über das Magnetventil geleitet
und kann so über den eingestellten pH-Sollwert an der
seramic reguliert werden. Je nach Beckengröße und
Calciumbedarf muss jetzt noch die Wasserdurchfluss-
menge durch den Calciumreaktor eingestellt werden.
Beachten Sie hierzu die Angaben der Gebrauchsinfor-
mation des Kalkreaktors.
1.2 Regelung des pH-Wertes nach oben durch Zugabe
von Pufferlösungen
Die Dosierung von Pufferlösungen oder Laugen zur Er-
höhung des pH-Wertes in Meerwasseraquarien wird
durch den Einsatz einer geeigneten Förderpumpe
(Schlauchpumpe, volumengesteuerte Pumpe) ermög-
licht. Der gewünschte pH-Wert wird an der seramic ein-
gestellt. Die Förderpumpe wird in die zu fördernde
Lösung eingetaucht und mit dem externen Stecker der
seramic verbunden. Wenn der eingestellte pH-Wert
erreicht ist, unterbricht die seramic die Stromversor-
gung zur Förderpumpe und der pH-Wert wird gehalten.
Sinkt er unter einen voreinstellbaren Wert ab (siehe
Schalthysterese), schaltet die seramic die Förderung
wieder ein.
Die Reaktionszeit der pH-Elektrode muss bei der Ein-
stellung der Förderleistung der Dosierpumpe berück-
sichtigt werden, damit nicht zuviel Lauge dosiert wird.
2. Der pH-Wert
Der pH-Wert beschreibt, ob eine Flüssigkeit sauer (pH
unter 7), neutral (pH = 7) oder alkalisch (pH über 7) ist.
In natürlichen Gewässern liegt der pH-Wert meist im
Bereich zwischen 5,5 und 8,0 bei Süßwasser und 7,5 – 8,5
bei Meerwasser.
Für Fische und Pflanzen im Gesellschaftsaquarium sind
pH-Werte zwischen 6,8 und 7,5 ideal. Wenn dieser pH-
Wert mittels gleichmäßiger CO2-Zufuhr auf einem kons-
tanten Wert gehalten wird, wachsen die Pflanzen deut-
lich besser. Auch viele Pflanzenarten, die sich bisher
nur einige Wochen im Aquarium gehalten haben, können
nun dauerhaft erfolgreich gepflegt werden (richtige
Beleuchtung vorausgesetzt). Darüber hinaus wird das
Algenwachstum gehemmt.
Typische pH-Werte
• zur optimalen Pflege von Diskus,
Skalaren, Roten Neon, Keilfleckbarben,
Zwergfadenfischen, Killifischen usw. 6,0 – 7,0
• im Gesellschaftsaquarium 6,8 – 7,5
• für Platies, Mollies, Guppies,
Malawi-/Tanganjika-Cichliden 7,5 – 8,5
• in natürlichem Meerwasser 8,1 – 8,4
• im Meerwasseraquarium 8,1 (morgens) –
8,4 (abends),
ideal: 8,2
3. Inhalt (3):
3.1 Digitaler seramic pH Controller mit Netzanschluss
3.2 Externer Stecker
3.3 Magnetventil
3.4 sera pH-Messelektrode
3.5 Rückschlagventil
3.6 2 Saughalter + Universalhalter für die pH-Elek-
trode
3.7 Universalhalteplatte
3.8 sera Prüflösung pH 4,0 (mit Sicherheits-Farbindi-
kator “rot”) 100 ml
3.9 sera Prüflösung pH 7,0 (mit Sicherheits-Farbindi-
kator “grün”) 100 ml
3.10 CO2-Schlauch 3 m
Gebrauchsinformation
4. Funktionen der seramic
Das Gerät zeichnet sich durch eine benutzerfreundliche
Bedienung aus und besitzt eine gut ablesbare LED-An-
zeige.
Folgende Funktionen sind ausführbar:
• Einstellen des pH-Sollwerts
• Kalibrieren der pH-Messelektrode
• Anzeigen des aktuellen pH-Werts
• Einstellen der Schalthysterese
Umschalten von pH-Wert-Absenkung (Lo) auf pH-Wert-
Erhöhung (Hi)
Der seramic pH Controller gibt im Display eine 2. Nach-
kommastelle (z. B. 7,57 pH) an. Die zweite (hundertstel
pH) Stelle soll lediglich zum Erkennen von Tendenzen
dienen. Sie kann niemals völlig stabil sein. Eine leichte
Bewegung oder ein minimales Wandern sind normal.
D
Gebrauchsinformation
Bitte vollständig und aufmerksam lesen.
5. Wichtige Hinweise
Bitte beachten Sie diese Bedienungsanleitung zur
Sicherung einer einwandfreien Funktion und langen
Lebensdauer des Geräts. Halten Sie außerdem unbe-
dingt die Einsatzbedingungen und zulässigen Daten
dieser Bedienungsanleitung ein.
Wird die seramic als CO2-Steueranlage eingesetzt, wird
die CO2-Zufuhr durch das mitgelieferte Magnetventil (3.3)
geregelt. (Die Inbetriebnahme des Magnetventils erfolgt
entsprechend der separaten Gebrauchsinformation).
Vor das Magnetventil muss ein Druckminderer (z. B. sera
CO2-Druckminderer für außen liegendes Ventil, Art.-Nr.
08035) geschaltet werden. Wir empfehlen bei Verwen-
dung der seramic als CO2-Anlage die sera precision CO2-
Düngeanlage (Art.-Nr. 08055) mit Druckminderer, CO2-
Flasche und CO2-Reaktor mit Blasenzähler.
Das Magnetventil wird durch einen CO2-Schlauch mit
dem Druckminderer verbunden und an die CO2-Druck-
gasflasche angeschlossen. Der maximal zulässige Ar-
beitsdruck beträgt 1 bar.
Ein Anschluss des Geräts an CO2-Durchflussregler oder
Feinnadelventile ohne vorgeschalteten Druckminderer
ist nicht erlaubt.
Bevor der Netzstecker eingesteckt wird, muss immer
erst die Elektrode angeschlossen sein!
6. Montage
Achtung: Vor der Montage Netzstecker ziehen!
Aufgrund der mitgelieferten Universalhalteplatte (4) kann
die seramic am Aquariumunterschrank oder an der Wand
montiert bzw. als Tischgerät aufgestellt werden.
ACHTUNG:
Das Steuergerät (3.1), das Magnetventil (3.3) und die mit-
gelieferte Steckdose (3.2) müssen sich immer an einer
trockenen Stelle befinden.
Bitte beachten Sie, dass die an der seramic angeschlos-
sene pH-Elektrode (3.4) dauerhaft im Aquarium befestigt
werden muss. Das 1,50 m lange Anschlusskabel der pH-
Elektrode sollte dabei locker verlegt werden.
Einbau in eine bereits installierte CO2-Anlage mit Bla-
senzähler und CO2-Reaktor
Schließen Sie die CO2-Zufuhr der Flasche sowie das Druck-
minder- und das Auslassventil (5). Wenn sich am Bla-
senzähler keine Blasen mehr zeigen, können Sie mit
dem Einbau beginnen. Schließen Sie das sera Magnet-
ventil zwischen Druckminderer und Blasenzähler wie
folgt an:
Entfernen Sie den CO2-Schlauch zwischen dem Auslass-
ventil des Druckminderers und dem Rückschlagventil (6).
Schneiden Sie von dem mitgelieferten CO2-Schlauch
zwei Stücke von geeigneter Länge ab. Mit dem ersten
Schlauchstück verbinden Sie Druckminderer und CO2-
Eingang des Magnetventils (siehe Pfeilrichtung) (7).
Schrauben Sie zur Befestigung den Ring ab, und schie-
ben Sie ihn über den Schlauch. Stecken Sie den
Schlauch bis zum Anschlag auf den Stutzen. Schieben
Sie den Ring am Schlauch hoch, und schrauben Sie ihn
handfest an (8). Mit dem zweiten Schlauchstück verbin-
den Sie auf die gleiche Weise den CO2-Ausgang des
Magnetventils mit dem Rückschlagventil (7).
Achtung:
Das Steuersystem darf nur in Verbindung mit mindes-
tens einem hochwertigen Rückschlagventil (z.B. sera
Rückschlagventil) betrieben werden.
Die Verwendung mindestens eines sera Rückschlagven-
tils bietet Sicherheit: Ist der CO2-Vorrat in der Flasche
unbemerkt erschöpft, schützt es das sera Magnetventil
zuverlässig gegen das Eindringen von Aquarienwasser.
Nach jedem Rücklauf von Wasser bis in das Rückschlag-
ventil ist dieses unbedingt auszutauschen, da es durch
mineralische Ablagerungen undicht werden kann.
7. Bedien- und Anzeigeelemente
Die folgende Abbildung zeigt die Gerätefront der sera-
mic. Das Gerät verfügt über ein vierstelliges Display zur
Anzeige von
• aktuellem pH-Wert bzw.
• pH-Sollwert
• Hi/Lo LED-Anzeige
• OUTPUT-Anzeige
Bedienfeld und Funktionen
Taste 1 und 2 müssen gleichzeitig gedrückt werden, um
ins Menü zu kommen.
Taste 1 Taste 2 Funktion / Beschreibung
pH-Sollwert einstellen
Sollwert senken bzw. erhöhen
Umschalten von Betriebsart
“pH senken” (CO2-Anlage) auf
“pH erhöhen” (Pufferdosierung)
Schalthysterese einstellen
Schalthysterese verkleinern
bzw. vergrößern
Kalibration mit pH 7,0 Prüflösung
Kalibration mit pH 4,0 Prüflösung
6
7
8. Inbetriebnahme
8.1 Vorbereitung der pH-Elektrode
Vor Montage und Inbetriebnahme der seramic muss die
Elektrode mindestens 12 Stunden lang in einem saube-
ren Glas in abgestandenem (chlorfreiem) Leitungswasser
gewässert werden (9). Entfernen Sie dazu vorsichtig die
Elektrodenschutzhülse. Ein eventuell vorhandener wei-
ßer Salzüberzug an der Elektrodenspitze ist unschädlich
und löst sich nach wenigen Minuten im Wasser wieder
auf. Min-Max-Eintauchtiefe beachten. War die Elektroden-
spitze für mehr als einige Minuten trocken, so ist die
Wässerung sogar dringend erforderlich. (Die Spitze der
Elektrode muss dauerhaft feucht gehalten werden.)
Bitte denken Sie beim Umgang mit der Elektrode immer
daran, dass nur der Elektrodenschaft aus Kunststoff
besteht. Die inneren Kapillarrohre sind jedoch aus Glas
und deshalb sehr schlagempfindlich. Zum Spülen der
Elektrode benötigen Sie destilliertes Wasser. Verwenden
Sie nur sera aqua-dest oder destilliertes Wasser aus der
Apotheke.
Anschließend stecken Sie den BNC-Stecker der Elektrode
in die entsprechende Buchse an der seramic ein. Nun
kann die Steueranlage über die mitgelieferte Steckdose
in Betrieb genommen werden.
8.2 Kalibrierung der pH-Elektrode
Der nächste Schritt ist die Kalibrierung der Elektrode.
Hierzu verwendet man die Prüflösungen 4,0 und 7,0 (3.8 /
3.9). Bitte verwenden Sie eine Messküvette (10 ml), um
den Verbrauch der Prüflösungen so gering wie möglich
zu halten. Benutzte Prüflösung nur einmal verwenden.
Geöffnete 100-ml-Flasche bitte sofort wieder schließen.
Sicherheits-Farbindikatoren der sera Prüflösungen
Achtung: Die sera Prüflösungen sind mit Farbindikato-
ren versehen. Die sera Prüflösung pH 4,0 ist rot, die sera
Prüflösung pH 7,0 ist grün. Verunreinigte oder zu alte
Prüflösungen verändern oder verlieren diese Farben.
Die Verwendung solcher Prüflösungen kann zu gefähr-
lichen Mess- und Regelfehlern führen!
Anmerkung: Nicht alle Verunreinigungen führen zu Farb-
abbau oder Farbumschlag, deshalb ist ein besonders
sorgfältiger Umgang mit den Prüflösungen unbedingt
notwendig. Prüflösungen niemals mehrfach verwenden
oder in die Flasche zurückfüllen!
Wir empfehlen, geöffnete Prüflösungen bei Zimmertem-
peratur maximal 12 Monate zu lagern, auch wenn die
Indikatorfarben noch intakt sind.
Mit der Senkung des pH-Werts greifen Sie maßgeblich
in die Wasserchemie ein. Plötzliche, deutliche Ände-
rungen des pH-Werts sind immer eine Gefahr für das
gesamte Biotop. Ändern Sie deshalb den Sollwert nicht
übermäßig und nur in möglichst kleinen Schritten über
mehrere Tage hinweg. Prüfen Sie in jedem Einzelfall,
ob der gewünschte Wert für alle Tiere und Pflanzen
verträglich ist. (Eine Tabelle als weitere Grundlage und
Empfehlung finden Sie auf S. 5, siehe “Typische pH-Wer-
te”. Beachten Sie dazu bitte auch Kap. 8.5, Aktivieren
der CO2-Zufuhr.)
Kalibrieren
pH 7 Spülen Sie die Elektrode mit Destwasser ab und
stecken Sie diese in die grüne sera Prüflösung
pH 7,0. Warten Sie mindestens 60 Sekunden.
Drücken Sie gleichzeitig die Tasten
und .
Das Display blinkt 3-mal mit dem pH-Wert
,
dann ertönt ein Signalton und der pH-Wert 7,00
ist gespeichert. Das Gerät ist sofort wieder im
Messmodus.
pH 4 Wiederholen Sie den Vorgang mit der sera Prüf-
lösung pH 4,0. Elektrode mit Destwasser spülen,
in die sera Prüflösung pH 4,0 eintauchen und
mindestens 60 Sekunden warten. Drücken Sie
gleichzeitig die Tasten
und .
Das Display blinkt 3-mal mit dem pH-Wert
.
Dann ertönt ein Signalton, das Gerät hat den pH-
Wert 4,00 gespeichert und geht automatisch in
den normalen Messmodus über. Der Kalibriervor-
gang ist beendet.
Sollte beim Kalibrieren ein Bedienungsfehler vor-
liegen, zeigt das Gerät
an!
Einstellen des pH-Sollwertes
Sie drücken die Tasten und gleichzeitig.
Im Display erscheint der “alte” voreingestellte pH-
Wert. Mit den Pfeiltasten können Sie jetzt den ge-
wünschten pH-Sollwert einstellen, bei dem das Gerät
die CO2-Zufuhr über das Magnetventil stoppt.
Sie drücken dazu bei gewünschter Erhöhung die Pfeil-
taste nach oben ,
bei Absenkung die Pfeiltaste
nach unten .
Ist der gewünschte Wert erreicht, drücken Sie mit
einem Finger die -Taste
und der eingestellte Wert ist gespeichert. Das Display
zeigt sofort wieder den derzeitigen pH-Wert des
Aquarienwassers an.
Verändern der Hysterese
Die Ein-/Ausschalthysterese gibt an, wie groß das Schalt-
fenster zwischen Ein- und Ausschalten ist. Bei einge-
stelltem pH-Sollwert von pH 7 und einer Schalthyste-
rese von 0,1 schaltet das Magnetventil die CO2-Zufuhr
bei pH 7,1 ein und bei Unterschreiten von pH 7 wieder
aus. Durch die Schalthysterese wird vermieden, dass
das Magnetventil bei kleinsten Schwankungen jedes
Mal ein- und ausschaltet. Der Verschleiß des Magnet-
ventils wird vermindert.
Durch gleichzeitiges Drücken der Tasten
und
wird im Display blinkend der Wert für die Ein-/Aus-
schalthysterese angezeigt.
Mit den Pfeiltasten können Sie diese noch erhöhen
oder herabsetzen. Nach Erreichen der gewünschten
Schalthysterese drücken Sie die Taste
,
nach ertöntem Signalton ist der Wert gespeichert und
das Gerät ist sofort wieder im normalen Messmodus.
Mit den Pfeiltasten kann der Wert schon ab der zwei-
ten Kommastelle durch ständiges Drücken in Einzel-
schritten verändert werden. Drückt man die Pfeiltaste
ständig durch, ohne den Finger zu entfernen, so läuft
der Wert nach einigen Sekunden schneller nach oben
bzw. nach unten, mit kurzen Unterbrechungen.
Somit können auch größere Wertänderungen des Soll-
wertes bzw. der Hysterese vorgenommen werden.
Wechseln von Hi auf Lo
Der Betriebsmodus “Lo” dient zur Regelung des pH-
Werts nach unten durch Zugabe von CO2(Betriebsmodus
zur Steuerung von CO2-Anlage und Kalkreaktor).
Haben Sie diesen Arbeitsmodus eingestellt, leuchtet die
Diode neben Hi/Lo rot.
Haben Sie die Geräteanordnung zur Erhöhung des pH-
Werts mittels Pufferlösungen gewählt, müssen Sie die
seramic auf den Betriebsmodus “Hi” (Erhöhen des pH-
Werts) umschalten.
Drücken Sie gleichzeitig die Tasten
und .
Jetzt ertönt ein Signalton und die Diode neben Hi/Lo
leuchtet grün, der Betriebsmodus “Hi” ist eingestellt.
Wenn Sie den Vorgang wiederholen, schalten Sie wie-
der in den Arbeitsmodus “Lo”.
8.3 Montage der pH-Elektrode im Süßwasseraquarium
Die beiden beigefügten Saughalter oder der Univer-
salhalter (3.6) müssen am Elektrodenschaft angebracht
werden. Mit Hilfe der Halter muss die pH-Elektrode in
der richtigen Höhe (10) innen an die Scheibe des
Aquariums befestigt werden, möglichst an einer dunk-
len Stelle. Bereiche mit starker Strömung sind eben-
falls zu meiden.
Die Elektrode darf nicht in der Nähe des CO2-Reaktors
angebracht werden (verfälschte Ergebnisse der pH-
Messung).
Es ist bei neuen pH-Elektroden darauf zu achten, dass
die Elektrode innerhalb der ersten Wochen im Abstand
von einigen Tagen immer wieder neu kalibriert wird.
Dazu gehen Sie wie vorher beschrieben vor. Unter der
Voraussetzung, dass das Gerät dauerhaft benutzt wird,
genügt es später, die Elektrode alle 4 – 6 Wochen erneut
zu kalibrieren.
8.4 Montage der pH-Elektrode im Kalkreaktor
(siehe 1.1.2)
8.5 Aktivieren der CO2-Zufuhr
Zum Aktivieren der CO2-Zufuhr wird zuerst das Magnet-
ventil geöffnet. Dazu muss der Sollwert des Steuergeräts
auf einen Wert unterhalb des angezeigten, tatsächlichen
pH-Werts eingestellt werden. Das Öffnen des Magnet-
ventils wird durch die rote Leuchtdiode (OUTPUT) ange-
zeigt.
Ziehen Sie dann vorsichtshalber den CO2-Schlauch vom
Blasenzähler ab und stecken das lose Ende in das
Aquarienwasser oder ein Glas mit Wasser. So können Sie
die Blasenanzahl vor einstellen, ohne Teile der Anlage
durch eventuellen Überdruck zu beschädigen.
Nun öffnen Sie die CO2-Zufuhr an der Flasche. Das
schwarze Handrad langsam leicht öffnen (nur bei Fla-
schen mit außen liegendem Ventil).
Die CO2-Zufuhr am Druckminderer wird geöffnet. Der
Druck am Arbeitsdruckmanometer darf jedoch 1 bar
nicht überschreiten. Dabei sind die jeweiligen Herstel-
lerangaben zu berücksichtigen.
Stecken Sie jetzt den CO2-Schlauch wieder auf den
Blasenzähler auf.
Nach dem Öffnen des Nadelfeinventils strömt nach kur-
zer Zeit CO2in das Aquarium.
Zur Funktionskontrolle erhöhen Sie nun den pH-Sollwert
so lange, bis das Magnetventil ausgeschaltet wird. Bei
einer Senkung des pH-Sollwerts wird das Magnetventil
wieder geöffnet.
Vergessen Sie nicht, jetzt wieder den gewünschten
pH-Sollwert einzustellen!
Karbonathärte pH-Einstellung am Steuergerät
0Karbonathärte
1mit sera KH/pH-plus
2auf 4 °dKH
3erhöhen
46,8
56,9
66,9
76,9
87,0
10 7,1
12 7,2
15 7,4
20 7,5
21 und höher Karbonathärte zunächst im Süßwasser
durch Torffilterung z.B. mit sera super
peat senken
Nach einigen Tagen können Sie den pH-Wert in Zehntel-
schritten weiter absenken, z.B. von 7,0 auf 6,9. Dabei ist
jedoch darauf zu achten, ob die Fische schneller atmen.
In diesem Fall machen Sie bitte die letzte pH-Senkung
wieder rückgängig. Bitte bedenken Sie: Je höher die
Karbonathärte ist, um so mehr CO2benötigen Sie, um
den pH-Wert zu senken. Viel gelöstes CO2verbessert
zwar die Bedingungen für die Wasserpflanzen, wird aber
nicht von allen Fischen gleich gut vertragen.
Bei den in der Tabelle angegebenen Werten befinden
sich CO2, pH-Wert und Karbonathärte im Gleichgewicht.
8
9
Achtung:
Bei niedrigen Karbonathärten (<4 °dKH) ist die Puffer-
(Säurebindungs-) kapazität des Wassers sehr niedrig.
Daher kann beispielsweise bei einem stark belasteten
Filter oder einem nicht unverzüglich entfernten toten
Fisch der pH-Wert drastisch sinken (Säuresturz). Deshalb
raten wir bei Karbonathärten unter 4 °dKH zu einer Er-
höhung mit sera KH/pH-plus.
9. Ratschläge und die Fehlersuchliste
Wichtige Hinweise zur pH-Elektrode
a. Während der Krankheitsbehandlung von Zierfischen
mit Arzneimitteln sowie der Bekämpfung von Algen
oder Schnecken darf die Elektrode nicht benutzt
werden (Elektrodenvergiftung)! Eine vergiftete Elek-
trode kann nicht repariert werden und begründet
keinen Garantieanspruch! Nehmen Sie während
einer Behandlung die Elektrode aus dem Aquarium
und setzen Sie die mit sera Pflegelösung KCl gefüllte
Schutzhülse auf die Elektrode. Vergessen Sie nicht,
auch die CO2-Steuereinheit während dieser Zeit ab-
zuschalten (Netzstecker ziehen und CO2-Flaschen-
ventil schließen), denn ohne die pH-Elektrode er-
folgt sonst völlig ungeregelte CO2-Zufuhr.
Auch darf die Elektrode nicht längere Zeit in den
Prüflösungen oder in destilliertem Wasser stehen
bleiben. Allein in sauberem Aquarienwasser oder in
sera Pflegelösung KCI darf eine Lagerung (länger als
einige Minuten) erfolgen. Setzen Sie die Elektrode
nie für einen anderen als den bestimmten Verwen-
dungszweck ein.
b. Bleibt die Anzeige während der Kalibrierung in den
Prüflösungen nach einer gewissen Zeit nicht stabil,
sondern wandert langsam in eine Richtung, ist die
Elektrode verschmutzt und muss gereinigt werden.
Dazu wird die Elektrodenspitze für maximal 10 Minu-
ten in die sera Reinigungslösung getaucht. Die Elek-
trode darf auf keinen Fall mit irgendwelchen Reini-
gungsmitteln oder mit einem rauen Tuch, einer harten
Bürste o.ä. gereinigt werden! Nach der Reinigung
wird die Elektrode zunächst wieder für 12 Stunden
in sera Pflegelösung KCl gestellt, danach gespült und
neu kalibriert.
c. Bitte achten Sie unbedingt darauf, dass die Elektro-
denspitze immer feucht bleibt. Bereits einminütiger
Luftkontakt kann zum Austrocknen der Elektrode und
damit zu falschen Messwerten führen! Auch in die-
sem Fall ist die Elektrode zunächst wieder 12 Stun-
den zu wässern und danach neu einzustellen.
d. Wasserwechsel
Vor dem Wasserwechsel sollten Sie die Elektrode aus
dem Wasser nehmen und die vorher mit Aquarien-
wasser oder sera Pflegelösung KCl gefüllte Schutzhül-
se auf die Elektrode stecken. Andernfalls trocknet
die Elektrode bei einem Absenken des Wasserstands
aus, was eine Neueinstellung erforderlich macht.
Bei trockener Elektrode kann fast jeder beliebige pH-
Wert angezeigt werden. Sollte die Elektrode zufällig
einen alkalischen pH-Wert melden, öffnet das Mag-
netventil und CO2 strömt unkontrolliert in das Aqua-
rium. Da die Elektrode nicht mehr reagiert, führt
dies schnell zu einer erheblichen Senkung des pH-
Werts.
Andere Möglichkeit: Sie lassen die Elektrode wäh-
rend des Wasserwechsels im Aquarium. Bohren Sie
dazu in eine etwa postkartengroße Styroporplatte
von ca. 25 mm Stärke ein Loch mit 12 mm Durch-
messer. Stecken Sie die Elektrode für die Dauer des
Wasserwechsels in dieses Loch. Die Styroporplatte
schwimmt auf dem sich in der Höhe verändernden
Wasserspiegel.
Achtung: Senken Sie bei dieser Methode den Wasser-
spiegel nicht so weit, dass die Elektrode an Steine
oder den Bodengrund stößt!
e. Eintauchtiefe der Elektrode (10)
Bitte beachten Sie den Eintauchbereich, der auf jeder
sera pH-Messelektrode angegeben ist. Zu flaches
Eintauchen kann falsche Messwerte ergeben. Zu tie-
fes Eintauchen kann zu Korrosion im Elektrodenin-
neren führen.
f. Alterung
Auch bei optimaler Pflege mit sera Reinigungslösung
und sera Pflegelösung KCl unterliegt jede pH-Elektro-
de technisch bedingter Alterung. Dadurch verlängert
sich die Reaktionszeit, bzw. die angegebenen Werte
werden ungenau und wandern. In diesem Fall sollte
sie gegen eine neue ausgetauscht werden. Bei be-
stimmungsgemäßem Gebrauch kann eine sera pH-
Messelektrode mehrere Jahre funktionstüchtig
sein. Dies gilt auch für die bloße Lagerung (Nichtge-
brauch). Die (begrenzte) Lebenszeit einer Elektrode
beginnt immer zum Produktionszeitpunkt.
Wasserrückfluss in/durch das Magnetventil (u.a. bei
Meerwasser):
Ausgelöst durch alte, defekte oder fehlende Sicherheits-
rückschlagventile kann Wasser (bei längerer Einwirkung)
das eingebaute CO2-Magnetventil zerstören.
Anmerkung: Sicherheitsventile können nach Wasser-
kontakt durch Ablagerungen undicht werden. Deshalb
sollten sie nach einem Kontakt mit zurückgeflossenem
Wasser ausgetauscht werden, auch wenn sie zu diesem
Zeitpunkt dicht sind.
Was ist zu tun, wenn Wasser aus dem Aquarium in das
Magnetventil zurückgeflossen ist?
1. Magnetventil öffnen.
2. Mit einem Schlauchstück einige Milliliter sera aqua-
dest zum Spülen hindurchdrücken, z.B. mit einer
Spritze. Ventil dabei mehrfach schalten lassen.
3. Membranpumpe anschließen und zum Trocknen
mehrere Stunden trockene Raumluft anstatt CO2
durch das geöffnete Magnetventil pumpen lassen.
Dabei mehrfach kurz schalten (schließen und wieder
öffnen) lassen.
Fehler Ursache Abhilfe
Anzeige wandert während der
Einstellung
Elektrode ist verschmutzt oder
veralgt
mit sera Reinigungslösung reinigen,
anschließend mit sera Pflegelösung
KCl pflegen
Elektrode war zu lange trocken Elektrode 12 Stunden wässern, neu
kalibrieren bzw. austauschen
CO2- oder Luftblasen kommen an
die Elektrodenspitze
vermeiden bzw. Elektrode anders
im Aquarium platzieren
Elektrode zu alt/defekt, Kabel defekt austauschen
Elektrode war/ist zu tief im Wasser austauschen oder anders platzieren
keine Anzeige Kabel oder Elektrode defekt austauschen
Wasser in Gehäuse gelangt Fachhandel
Stecker nicht in der Steckdose einstecken
Anzeige falscher Werte zu alte oder verunreinigte
Prüflösungen
neue Prüflösungen kaufen
Schutzhülse steckt auf Elektrode Schutzhülse abnehmen
Anzeige “Err” während des
Kalibriervorganges
Kalibrierfehler Gerät neu kalibrieren, siehe “Kalibrier-
vorgang” (S. 7).
Sind die Prüflösungen intakt?
Trotz niedrigem pH-Wert gibt die
Steueranlage CO2in das Aquarium /
Trotz zu hohem pH-Wert gibt die
Anlage kein CO2ins Aquarium /
Magnetventil schaltet nicht mehr
Magnetventil ist infolge
Wasserschadens defekt, weil kein
Rückschlagventil eingebaut war
oder dieses defekt ist
Reparatur (Fachhandel)
Magnetventil öffnet nicht mehr Arbeitsdruck am Druckminderer zu
hoch (höher als 1 bar)
zunächst manuelle Kontrolle: dazu
Gaszufuhr an Flasche, Druckminderer
und Auslassventil schließen. CO2-
Schlauch vom Auslassventil abziehen.
Durch Verändern des pH-Sollwerts
prüfen, ob Steuereinheit schaltet.
Wenn nicht: Fachhandel, wenn ja:
Schlauch wieder anschließen und
Arbeitsdruck (1 bar), wie in der
Gebrauchsinformation beschrieben,
korrekt einstellen.
pH-Wert steigt trotz geöffneten
Magnetventils
CO2-Flasche geschlossen Flasche öffnen
Druckgasflasche leer füllen lassen
Durch Ausströmerstein, Diffusor o.ä.
wird das CO2-Gas aus dem Wasser
getrieben
Luftperlung im Wasser vermeiden
Maximale Aquariengröße überschrit-
ten
CO2-Zufuhr erhöhen und zusätzliche
sera CO2-Düngeanlage anschließen
keine CO2-Blasen im Blasenzähler Druckminderer falsch eingestellt (zu
geringer oder gar kein Arbeitsdruck)
Arbeitsdruck erhöhen
Rückschlagventil falsch angeschlos-
sen
Anschlüsse des Ventils prüfen und
ggf. korrigieren
Sicherheits-Rückschlagventil ver-
stopft oder fehlerhaft
austauschen
Leck im Schlauchsystem oder in den
Schlauchanschlüssen
Schläuche und Anschlüsse prüfen
und ggf. Schläuche austauschen
CO2-Verbrauch zu hoch Leck im CO2-Schlauchsystem oder
Schläuche zu lang
Schlauch austauschen oder kürzen
Arbeitsdruck zu hoch Arbeitsdruck am Druckminderer
senken
O-Ring zwischen Druckminderer-
Armatur und CO2-Flasche defekt/
verschmutzt
austauschen
Reaktor verschmutzt oder
Wasserdruck zu niedrig, CO2-Blasen
steigen auf
Reaktor reinigen oder mehr Wasser
in den Reaktor leiten
Fehlersuchliste
10
11
10. Technische Daten
seramic pH Controller:
Gehäuse spritzwassergeschützt *
pH-Regelgerät mit benutzergeführter Kalibrierung
Versorgungsspannung 230 V/50 – 60 Hz
optional 115 V/50 Hz; 110 V/60 Hz
Leistungsaufnahme gesamt 2 VA (Watt)
Messgenauigkeit ±0,1 pH-Einheiten
(bei 25 °C/77 °F)
Messbereich (pH-Wert) pH 2 – 12
Regelbereich (pH-Wert) pH 4 – 9
Schaltverzögerung pH 0 bis 2
in Schritten von 0,01
Display 4-stellige LED-Anzeige
Eingangswiderstand
pH-Elektrode im Gigaohm-Bereich
sera CO2-Magnetventil:
Leistungsaufnahme gesamt 1,6 VA (Watt)
Max. Druckbelastung 5,5 bar
Umgebungstemperatur 0 – 50 °C (32 – 122 °F)
Schlauchanschluss 4/6 mm (Innen-/Außen-
durchmesser)
Schaltsteckdose:
Schaltleistung max. 1.000 W
max. Belastbarkeit 5A bei 250 V~
* Der Steckverbinder zum Anschluss der pH-Elektrode (Stecker
an der Elektrode) ist nicht feuchtigkeitsgeschützt. Falls diese
Steckverbindung Feuchtigkeit ausgesetzt wird, kann die pH-
Wert-Messung extrem stark verfälscht werden, was zu einer
unkontrollierten CO2-Zufuhr führen kann.
11. Ersatzteile und Zubehör:
sera pH-Messelektrode (Art.-Nr. 08921)
sera CO2-Magnetventil (Art.-Nr. 08030)
sera Prüflösung pH 4,0 (Art.-Nr. 08916)
sera Prüflösung pH 7,0 (Art.-Nr. 08923)
sera CO2-Schlauch 4/6 (Art.-Nr. 08022)
sera Rückschlagventil (Art.-Nr. 08818)
Entsorgung des Gerätes:
Altgeräte dürfen nicht in den Hausmüll!
Sollte das Gerät einmal nicht mehr benutzt werden
können, so ist jeder Verbraucher gesetzlich verpflichtet,
Altgeräte getrennt vom Hausmüll z.B. bei einer Sam-
melstelle seiner Gemeinde/seines Stadtteils abzuge-
ben. Damit wird gewährleistet, dass die Altgeräte fach-
gerecht verwertet und negative Auswirkungen auf die
Umwelt vermieden werden.
Deswegen sind Elektrogeräte mit
folgendem Symbol gekennzeichnet:
Fehler Ursache Abhilfe
CO2-Verbrauch zu hoch zu starke Belüftung des Aquariums,
keine Abdeckung
CO2-Ausgasung reduzieren, indem
Sie die Sauerstoffzufuhr reduzieren
Kontermutter am Einstellrad des
sera CO2-Druckminderers hat sich
gelockert
Kontermutter von Hand fest an-
ziehen. Keinen Schraubschlüssel
verwenden!
Gewindeschraube am Druckminderer
wurde zu fest angezogen (Anzeige
im ROTEN Bereich). Sicherheitsventil
öffnet, und CO2entweicht unter
Zischen
Gewindeschraube sofort lösen.
Bereits aufgebauten Druck durch
Öffnen des Auslassventils (Handrad)
entweichen lassen. Handrad schlie-
ßen und Gewindeschraube sehr
langsam anziehen, so dass der
Arbeitsdruck 1 bar beträgt
Elektrode zeigt im Innern des
Schaftes verfärbungen
Elektrode ist durch Arzneimittel
vergiftet
austauschen
Fische stehen schwer atmend an
der Wasseroberfläche oder schießen
ruckartig durchs Wasser
aus dem Wasser ausgegastes CO2
staut sich unter der Abdeckung
für bessere Luftzirkulation sorgen
pH-Wert ist im Verhältnis zur
Karbonathärte zu niedrig eingestellt
10 – 20 % Teilwasserwechsel durch-
führen, anschließend pH-Wert höher
einstellen
Filter läuft nicht mehr einwandfrei Filter reinigen
Aquarienwasser ist stark belastet Teilwasserwechsel mit
Bodengrundreinigung durchführen
Garantie:
Bei Beachtung der Gebrauchsinformation arbeitet der
seramic pH Controller zuverlässig. Wir haften für die
Fehlerfreiheit unserer Produkte ausschließlich im Rah-
men der gesetzlichen Bestimmungen ab dem Kaufda-
tum (Ausnahme: 12 Monate auf die Elektrode).
Wir haften für vollständige Mängelfreiheit bei Übergabe.
Sollten durch bestimmungsgemäßen Gebrauch übliche
Abnutzungs- oder Verbrauchserscheinungen auftreten,
stellt dies keinen Mangel dar. In diesem Fall sind auch
die Gewährleistungsansprüche ausgeschlossen.
Wir empfehlen Ihnen für jeden Fall eines Mangels, sich
zunächst an den Fachhändler zu wenden, bei dem Sie
das Gerät erworben haben. Er kann beurteilen, ob tat-
sächlich ein Garantiefall vorliegt. Bei einer Zusendung
an uns müssen wir Ihnen etwaige unnötigerweise an-
fallende Kosten belasten.
Jegliche Haftung wegen Vertragsverletzung ist auf Vor-
satz und grobe Fahrlässigkeit beschränkt. Nur für die
Verletzung von Leben, Körper und Gesundheit, bei Ver-
letzung wesentlicher Vertragspflichten und bei einer
zwingenden Haftung nach dem Produkthaftungsge-
setz haftet sera auch bei leichter Fahrlässigkeit. In die-
sem Fall ist die Haftung dem Umfang nach auf den
Ersatz der vertragstypisch vorhersehbaren Schäden
begrenzt.
Bitte beachten Sie die Zusatzinformationen zur Ga-
rantie (*).
Zusatzinformationen zur Garantie (*):
Eine neue pH-Elektrode ist eine kürzlich Hergestellte.
Elektroden altern, auch wenn sie nicht benutzt wer-
den. Die Lebenserwartung liegt je nach exakter Was-
serchemie, Pflege und Anwendungsbereich bei
wenigen Monaten bis zu einigen Jahren.
Garantieausschluss bei durch Arzneimittel, Farb-
stoffe oder Chemikalien vergifteten Elektroden, bei
Algenbelägen oder Verschmutzungen. Ebenso Ga-
rantieausschluss bei Lagerung in destilliertem
Wasser oder Prüflösungen, bei durch Austrocknung
unbrauchbar gewordenen Elektroden sowie bei sol-
chen mit Kabelschäden oder gebrochenen oder
durch sonstige unsachgemäße Verwendung zerstör-
ten Elektroden. Bei sachgemäßer Verwendung
gewähren wir auf die Elektrode dennoch 12 Monate
Garantie.
Magnetventil: In das externe Magnetventil zurückge-
flossenes Wasser (siehe Kap. Wasserrückfluss) kann das
Ventil zerstören. Dies ist kein Garantiefall. Eine Repa-
ratur bzw. ein Austausch ist jedoch möglich. Bitte
wenden Sie sich in diesem Fall an Ihren Fachhändler.
12
13
Congratulations on the purchase of this high quality
seramic pH controller!
1. Features and field of application
The microprocessor controlled seramic pH Controller
monitors the pH value setting in fresh and salt water
aquariums. The seramic pH Controller measures the pH
value via the connected sera pH electrode and regu-
lates the pH value to the required value via the con-
nected hose device, solenoid valve or pump.
Carbon dioxide dosage in freshwater aquariums and
operating a calcium reactor in marine aquariums are
typical application fields of the seramic.
1.1 Lowering the pH value by adding CO2
1.1.1 Application as CO2fertilizing system (1)
Fertilizing aquarium plants by directed and controlled
CO2addition is the most common application of the
seramic in freshwater aquariums.
The CO2is dosed by a solenoid valve (included with the
kit). The solenoid valve is triggered by the external
plug that receives its signal from the seramic. The
desired pH value of the water is precisely adjusted with
the keys of the seramic. As CO2and carbonic acid are
acidic, the seramic will lower the pH value when used
in this setup. The seramic will close the solenoid valve
via the external plug when the desired value is
attained.
1.1.2 Application as control unit for a calcium reactor (2)
For regulating a calcium reactor, the sera pH electrode
must be installed tightly in the assigned opening of
the calcium reactor. The CO2supply of the calcium
reactor is directed through the solenoid valve and can
thus be regulated by means of the desired pH value
selected on the seramic. Depending on tank size and
calcium requirement, you must now adjust the water
flow rate of the calcium reactor. Please consult the
instructions for use as provided by the manufacturer
of the unit to do so.
1.2 Raising the pH value by adding buffer solutions
Dosing buffer solutions or alkalines for raising the pH
value in saltwater aquariums is possible by using a suit-
able feed pump (hose pump, volume triggered pump).
The desired pH value is selected on the seramic. The
feed pump is immersed in the solution to be delivered
and connected to the external plug of the seramic.
When the selected pH value is attained, the seramic
will interrupt the power supply of the feed pump, and
the pH value is maintained. If it sinks below a preselect-
able value (see switching delay) the seramic will switch
on the feed pump again.
The reaction delay of the pH electrode must be consid-
ered when adjusting the pump performance as to pre-
vent too much alkalines being added.
2. The pH value
The pH value shows whether a liquid is acidic (pH below
7.0), neutral (pH = 7.0), or alkaline (pH above 7.0). In nat-
ural waters, pH values are mostly between 5.5 and 8.0
with freshwater and between 7.5 and 8.5 with saltwa-
ter.
pH values between 6.8 and 7.5 are suitable for fish and
plants in a community aquarium. If this pH value is sta-
ble and maintained by appropriate CO2addition, the
plants will grow considerably better. Many species of
plants that could only endure a few weeks in the
aquarium can now be kept for the long term (correct
lightning provided). Of course, the aquarium must be
equipped with the correct lighting as well.
Typical pH values
• for optimum care of discus,
angelfish, cardinal tetra,
dwarf gouramis, killifish, etc. pH 6.0 – 7.0
• in the community aquarium pH 6.8 – 7.5
• for platies, mollies, guppies,
Malawi/Tanganyika cichlids pH 7.5 – 8.5
• in natural saltwater pH 8.1 – 8.4
• in saltwater aquariums pH 8.1 (morning) –
8.4 (evening)
Ideal pH: 8.2
3. Contents (3):
3.1 Digital seramic pH Controller with power con-
nector
3.2 External plug
3.3 Solenoid valve
3.4 sera pH measuring electrode
3.5 Non-return valve
3.6 2 suction cups and universal holder
3.7 Universal holder
3.8 sera test solution pH 4.0 (with security color
indicator “red”) 100 ml (3.38 fl.oz.)
3.9 sera test solution pH 7.0 (with security color
indicator “green”) 100 ml (3.38 fl.oz.)
3.10 3 m (9.9 ft.) CO2hose 4/6
Directions for use
4. Functions of the seramic
The system is user friendly with an easy to read LED
display.
The control unit operates on the following functions:
• adjustment of the desired pH value
• calibration of the pH electrode
• display the present pH value
• adjustment of the switching delay
switching from lowering the pH value (Lo) to raising
the pH value (Hi)
The display of the seramic pH Controller shows a 2nd
decimal place (e.g., 7.57 pH). The 2nd (hundredth pH) is
for recognizing tendencies only and will never be com-
pletely stable. Light differences or a slight wandering
are considered normal.
US
Information for use
Please read completely and carefully before assembling the seramic pH Controller.
5. Important notes!
To ensure proper functioning and durability of the sys-
tem, the user must thoroughly understand the
instructions for use and comply with the application
conditions.
The included solenoid valve (3.3) will regulate the CO2
supply if you use the seramic as a CO2controller.
(Please see the separate instructions for use for putt-
ing the solenoid valve into operation.)
A pressure reducer (e.g. sera CO2pressure reducer for
external valve, item No. 08035) must be installed
before the solenoid valve. We recommend the sera
precision CO2fertilization system (item No. 08055) with
pressure reducer, CO2bottle and CO2reactor with bub-
ble counter when using the seramic as a CO2con-
troller.
The solenoid valve is connected to the pressure reduc-
er with a CO2hose. The maximum operating pressure
is 1 bar (14.5 psi.).
Do not connect the seramic pH Controller without a
pressure reducer valve from the CO2 bottle!
Always connect the pH electrode to the control unit
before the electrical cord is plugged in.
6. Assembly
Attention: Unplug all electrical devices before instal-
lation!
The included universal holder (4) allows to attach the
seramic to the aquarium cabinet or the wall, or to place
it on a table.
ATTENTION:
The control unit (3.1), the solenoid valve (3.3) and the
included socket (3.2) must always be located in a dry
place.
The junction of the pH electrode (3.4) is always
immersed in the aquarium water. The 1.5 meter (5 ft.)
flexible cord of the pH electrode should be laid freely
and connected to the control unit.
Integration of seramic pH Controller to an existing in-
stalled CO2system with bubble counter and CO2reactor
Procedure:
Shut off the CO2supply. The pressure reducer and the
outlet valve should remain shut off (5) as well. You may
begin with the installation when the bubbles stop
escaping in the bubble counter.
Connect the sera solenoid valve between pressure
reducer and bubble counter as follows:
Remove the hose that runs between the outlet of the
pressure reducer valve and inlet of the non-return
valve (6). Cut the supplied CO2hose to make two hoses
of suitable lengths. Connect one hose between the
outlet of the pressure reducer valve and the CO2intake
of the solenoid valve (see direction of the arrow) (7). To
secure, unscrew and slip the hose into the retainer
ring of the CO2intake. Insert the hose into the plastic
nozzle of the CO2intake as far as possible. Screw and
tighten the retainer ring to the CO2intake (8). In the
similar fashion, connect the second hose to the CO2
outlet of the solenoid valve and the non-return valve (7).
Caution:
The control system should always be installed with at
least one high-quality non-return valve (e.g., sera non-
return valve).
Use at least one sera non-return valve for safety reason.
The non-return valve will prevent any back-siphoning
of aquarium water when the CO2bottle has become
empty protecting the sera solenoid valve from water
damage. Every time water has been drawn back into the
non-return valve it must be replaced, as it can become
leaky due to mineral deposits.
7. Operational features, displays and adjustment of
desired pH value
The illustration shows the front panel of the seramic.
The unit is equipped with a four-figure display that
tells
• momentary pH value or
• desired pH value
• Hi/Lo LED display
• OUTPUT display
Operation panel and functions
Keys 1 and 2 must be pressed at the same time as to
enter the menu.
Key 1 Key 2 Function / Description
adjustment of desired pH value
lower or raise desired pH value
switching from function
“lower pH” (CO2system) to
“raise pH” (buffer dosage)
adjustment of hysteresis
lower or raise hysteresis
calibration with test solution
pH 7.0
calibration with test solution
pH 4.0
14
15
8. Starting up
8.1 Preparing of the pH electrode
Before installing the seramic, soak the pH electrode in
distilled water in a clean glass with old, chlorine-free
water for at least 12 hours (9). To do this, carefully
unscrew and remove the electrode protection cap. A
white salt-like deposit may coat the electrode tip. This
is normal and dissolves after a few minutes in the
water. Observe Min/Max immersion depth. This is more
urgently required if the electrode tip has been dry for
more than a few minutes. (The electrode tip must be
kept permanently moist.)
Keep in mind that only the electrode shaft is made of
plastic. The inner capillary tubes, however, are made of
glass and very fragile. To rinse the electrode you will need
distilled water. Use only sera aqua-dest or distilled water
from the pharmacy.
Then connect the BNC plug of the electrode to the cor-
responding socket of the seramic. Now the control unit
can be put into operation by plugging in the mains plug
into the supplied socket.
8.2 Calibration of the pH electrode
The next step is to calibrate the pH electrode using the
test solutions pH 4.0 and 7.0 (3.8/3.9). Please use a meas-
urement vial (10 ml) as to keep test solution consumption
as low as possible. Do not use a used test solution again.
Please close the opened 100 ml (3.38 fl.oz.) bottle imme-
diately again.
Safety color indicators of the sera test solutions
Caution: The sera test solutions contain color indica-
tors. The sera test solution pH 4.0 is red, the sera test
solution pH 7.0 is green. Test solutions that are dirty or
too old change or lose these colors. Using such test
solutions can lead to dangerous measuring and regu-
lation errors!
Note: Not all impurities cause color destruction or color
change. Therefore it is especially important to treat the
test solutions carefully. Never use test solutions more
than once or fill them back into the bottle!
We recommend storing opened test solutions for a
maximum of 12 months at room temperature, even if
the color indicators are still intact.
Lowering the pH value has a major influence on water
chemistry. Sudden and considerable pH value changes
are always a threat for the whole biotope. Therefore,
please do not change the desired value too strongly,
and only in steps as small as possible over several days.
For all changes, check if the desired value is suitable for
all animals and plants. (You will find a chart as a further
basis and recommendation on page 13, typical pH values.
Please also pay attention to section 8.5, activating and
dosing CO2.)
Calibration
pH 7 Rinse the electrode with distilled water and
immerse it into the green sera test solution pH
7.0. Wait for at least 60 seconds. Press the keys
and
at the same time. The display will flash 3 times
showing pH
,
then you will hear a signal sound indicating that
the pH value 7.00 is stored. The unit will immedia-
tely return to measuring mode.
pH 4 Repeat this procedure with the sera test solu-
tion pH 4.0. Rinse the electrode with distilled
water, immerse into the sera test solution pH 4.0
and wait for at least 60 seconds. Press the keys
and
at the same time. The display will flash 3 times
showing pH
,
then you will hear a signal sound indicating that
the pH value 4.00 is stored. The unit will immedia-
tely return to measuring mode. The calibration
procedure is now finished.
The unit will display
in case of a mistake during the calibration pro-
cedure.
Adjusting the desired pH value
Press the keys and at the same time.
The “old” preselected pH value will appear in the dis-
play. Using the arrow keys, you can now set the
desired pH value at which the unit will stop the CO2
supply via the solenoid valve.
•To do so, press the
upward arrow key
if you wish to raise the pH value, and the
downward arrow key
if you wish to lower it.
Press the key
once the desired value is attained, and the adjusted
value will be stored. The display will immediately
show the current pH value of the aquarium water.
Altering the hysteresis
The hysteresis for switching on/off tells how wide the
switching range between switching on and off is. With
an adjusted desired pH value of pH 7 and a switching
hysteresis of 0.1 the solenoid valve will switch on the
CO2supply at pH 7.1, and will switch it off again when
the pH value sinks below pH 7. The switching hystere-
sis avoids the solenoid valve switching on and off every
time there is a minor variation. Wear and tear of the
solenoid valve is reduced.
When pressing the keys
and
at the same time, the display will show the values for
the hysteresis for switching on/off flashing.
You can increase or lower it with the arrow keys. Press
the key
after the desired switching hysteresis is attained. The
value will be stored when you hear the signal sound,
and the unit immediately returns into normal measur-
ing mode.
The arrow keys allow to change the value in separate
steps even from the second decimal place by pressing
them permanently. If you press the arrow key perma-
nently without removing the finger, after a few sec-
onds the value will accelerate getting higher or lower
with short intervals.
This allows even large alterations of the desired value
or the hysteresis.
Changing from Hi to Lo
The operation mode “Lo” allows lowering the pH value
by adding CO2(operation mode for controlling CO2fer-
tilization system and calcium reactor).
The LED beside Hi/Lo will glow red if you have selected
this operation mode.
If you choose the unit setup for raising the pH value
with buffer solutions, you must switch the seramic to
the operation mode “Hi” (raising the pH value). Press
the keys
and
at the same time.
You will now hear a signal sound, and the LED beside
Hi/Lo will glow green. The operation mode “Hi” is now
selected. If you repeat this procedure you will switch
the unit back into the operation mode “Lo.”
8.3 Assembly of the pH electrode in freshwater aquar-
iums
Attach the two suction cups (supplied) or the universal
holder (3.6) to the pH electrode shaft. Then place and
attach the suction cups with the pH electrode to the in-
side glass of the aquarium. The pH electrode should have
the correct immersion depth (10), and if possible, be
set in a dark place. Avoid areas with a strong current.
Do not place the pH electrode close to the reactor. This
may result in false reading of pH measurement.
A new pH electrode needs a period of “breaking in,”
and it is necessary to recalibrate every few days for the
first few weeks. Follow the procedure as described
above. On the premise that the pH electrode is used
constantly, recalibrate the pH electrode every 4 –
6 weeks after that.
8.4 Installing the pH electrode in a calcium reactor
(see 1.1.2)
8.5 Activating and dosing CO2
First open the solenoid valve for activating the CO2
supply. You must set the desired value on the control
unit to a value below the displayed actual pH value to
do so. The opening of the solenoid valve is indicated by
the red LED (OUTPUT).
Then pull the CO2hose off the bubble counter for safe-
ty reasons and place the loose end in the aquarium
water or a glass filled with water. This allows you to
pre-adjust the bubble number without the risk of dam-
aging parts of the system by too high pressures.
Now open the CO2addition at the bottle (for bottles
with external valve only: Open the CO2at the bottle by
slowly and slightly opening the hand-wheel).
The CO2supply at the pressure reducer is opened. How-
ever, the pressure on the operating pressure manome-
ter must not exceed 1 bar (14.5 psi.). Consider the res-
pective data provided by the manufacturer.
Now put the CO2hose back on the bubble counter.
Shortly after opening the needle valve, CO2will flow
into the aquarium.
For functional control, now raise the desired pH value
until the solenoid valve switches off. If the desired
value is lowered, the solenoid valve opens again.
Do not forget now to re-adjust the desired pH value!
value of carbonate pH adjustment at the control unit
hardness
0use sera KH/pH-plus
1to increase
2carbonate hardness
3to 4°dKH
46.8
56.9
66.9
76.9
87.0
10 7.1
12 7.2
15 7.4
20 7.5
21 and higher rst lower the carbonate hardness
by filtering via peat, e.g. sera super
peat
After a few days, you can continue to lower the pH value
in steps of one-tenth of a pH unit, e.g., from 7.0 to 6.9.
When doing so, watch out for accelerated breathing
behavior of the fish. If this happens, reverse to the last
pH value. Remember! The higher the carbonate hard-
ness, the more CO2is required in order to lower the pH
value. Large amounts of dissolved CO2improve the living
conditions for the water plants but may not be tolerated
equally as well by all the fish.
With the values as stated in the chart, CO2, pH value and
carbonate hardness are in equilibrium.
With low carbonate hardness (<4°dKH), the buffering
capacity (ability to bind acids) of the water is at a high
risk. Negligible influences, such as a heavily burdened
filter or a dead fish that has not been removed imme-
diately, will cause the pH value to drop drastically (acid
drop). We recommend increasing the carbonate hard-
ness with sera KH/pH-plus if it is below 4°dKH.
16
17
9. Tips and troubleshooting
Important tips for pH electrode care
a. Do not use the pH electrode during treatment of
fish disease, treatment of algae, or while combating
a snail infestation. (re: contamination)! A contami-
nated electrode cannot be repaired and is not cov-
ered under warranty claim! Remove the electrode
from the aquarium during treatment and put it into
the protection cap, filled with sera care solution KCl.
Remember to switch off the CO2control unit, shut
off the pressure reducer valve and remove the plug
of the control unit. Otherwise, uncontrolled CO2
addition to the aquarium can occur without the pH
electrode.
Do not leave the electrode standing in the test solu-
tions or in distilled water for lengthy periods of
time. Storage (exceeding a few minutes) is permit-
ted only in clean aquarium water or in sera care
solution KCl. Never use the electrode for any other
than the intended purpose.
b. If the display on the control unit does not remain
stable after a certain time during calibration in the
test solutions, but drifts slowly into one direction,
the electrode is dirty and needs cleaning. Immerse
the tip of the pH electrode in the sera cleaning solu-
tion for 10 minutes maximum. You must never clean
the pH electrode with common cleaning solutions,
cloth, brush or the like! After cleaning, soak the pH
electrode in sera care solution KCl for 12 hours, then
rinse with distilled water and recalibrate.
c. Please note that the pH electrode tip must stay
moist always. It dries out within a short time when
in contact with air, and this leads to incorrect meas-
uring results. In such cases, soak the pH electrode
for 12 hours then recalibrate.
d. Water change
Before the water change, remove the pH electrode
and put it into the protection cap filled with aquar-
ium water or sera care solution KCl. Otherwise, the
electrode will dry out when the water level is low-
ered, which requires recalibration.
If the electrode is dried out, it creates havoc on the
control unit and displays a false pH value. Should the
electrode accidentally report an alkaline value, the
solenoid valve will open and cause uncontrollable
CO2flow into the aquarium. The pH electrode does
not react any longer, leading to a rapid decrease of
the pH value in the aquarium.
Another possibility: Leave the electrode in the
aquarium water during water change. Drill a hole of
12 mm (0.5 in.) diameter into a postcard-sized Styro-
foam plate with a thickness of about 25 mm (1 in.).
Insert the pH electrode into this hole and let it float
during the water change.
Important! When applying this method, do not lower
the water to the extent that the tip of the pH elec-
trode is in contact with the stones or gravel at the
bottom!
e. Immersion depth of the electrode (10)
Follow the immersion-depth indicators on the sera
pH electrode. Insufficient immersion may lead to
erroneous measurements. Immersing too deep may
cause corrosion within the electrode.
f. Aging
Although the pH electrode can be optimally cared
for with sera cleaning solution and sera care solu-
tion KCl, every pH electrode is technically subject to
aging. Symptoms of aging are, delayed reaction
time, inaccurate and drifting display values, etc. In
this case, replace the pH electrode by a new one.
Proper use provided, a sera pH electrode may func-
tion for several years. This includes storage (non-
use) time. The (limited) life span of an electrode
always begins at the time it is manufactured.
Water flowing back into/through the solenoid valve
(among other, in saltwater):
Caused by old, defective or missing safety non-return
valves, water may enter and destroy the built-in CO2
solenoid valve (in case of longer exposure).
Note: Safety valves can become leaky due to deposits
after contact with water that has flowed-back, even if
the connections are tight at this time.
What to do if the water from the aquarium has flowed-
back into the solenoid valve.
1. Open the solenoid valve.
2. Press through a few milliliters sera aqua-dest with a
hose piece, e.g. by using a syringe. Allow the valve
to switch several times while doing so.
3. Connect a membrane pump and allow it to pump
dry room air instead of CO2through the open sole-
noid valve for several hours. Allow the valve to switch
(close for a short time and reopen) several times
while doing so.
Problem Possible cause Troubleshooting
Readout display drifts during
adjustment
Electrode is dirty or covered with
algae
Clean with sera cleaning solution,
then soak in sera care solution KCl
Electrode has been dried for long
period
Soak electrode for 12 hours, then
recalibrate. Replace electrode if
electrode calibration is unsuccessful
CO2or air bubbles reach the tip of
electrode
Move the electrode to another
place in the aquarium
Electrode too old / defective Replace
Electrode was / is immersed too
deep in the water
Replace or move electrode to
another place in the aquarium
No display shown Defective cable or electrode Replace
Water has entered the control unit See your retailer
Control unit is not connected to
electrical outlet
Plug it in
Incorrect values displayed Too old or contaminated test
solutions
Replace with new test solutions
Protection cap left on the electrode Remove protection cap
Display shows “Err” during calibra-
tion process
Calibration mistake Recalibrate, see “Calibration
process” (page 15).
Are the test solutions intact?
Despite low pH value, the system
releases CO2into the aquarium /
Despite high pH value, the system
does not release CO2into the aquar-
ium / Solenoid valve is not working
Solenoid valve is defective caused
by water damage. Either non-return
valve was not used or the non-
return valve is defective
Needs repair (see your retailer)
Solenoid valve will not open Operating pressure at the pressure
reducer is too high – above 1 bar
(14.5 psi.)
At first manual control: close CO2
supply at the bottle. Shut off pres-
sure reducer and outlet valves.
Remove CO2hose from outlet valve.
Find out whether control unit is
working by changing the desired pH
value. If not see your retailer. If
yes, attach hose again and adjust
operating pressure (1 bar / 14.5 psi.)
correctly as described in the instruc-
tions for use
Troubleshooting
pH value rises despite the solenoid
valve is open CO2bottle is closed Open CO2bottle
CO2bottle is empty Refill CO2bottle
CO2gas is expelled from water by
air stone, air diffusor, etc.
Avoid air bubbling in the water
Exceeds the maximum aquarium
size
Increase CO2addition and install
additional sera CO2fertilization sys-
tem
No bubbles in the bubble counter Pressure reducer incorrectly adjust-
ed (insufficient or no operating
pressure)
Increase operating pressure
Non-return valve incorrectly con-
nected
Check valve fittings and correct
connection if necessary
Non-return valve clogged or
defective
Replace
Leakage in hose system or in the
hose fitting
Check hoses and fittings and
replace hoses if necessary
CO2consumption too high Leakage in CO2hose system or
hoses too long
Replace or shorten hose
Operating pressure too high Lower operating pressure at the
pressure reducer
Sealing ring between pressure reduc-
er and CO2bottle defective / dirty Replace
Reactor dirty or water pressure too
low, CO2bubbles escape Clean reactor or direct more water
into the reactor
18
19
10. Technical Data
seramic pH Controller:
Case protected against water splashing *
pH control unit with user guided calibration
Supply voltage 230 V/50 – 60 Hz
optionally 115 V/50 Hz; 110 V/60 Hz
Total operating energy input 2 VA (Watts)
Measurement precision ±0.1 pH units
(at 25°C/77°F)
Measuring range (pH value) pH 2 – 12
Control range (pH value) pH 4 – 9
Switching delay pH 0 to 2
in steps of 0.01
Display 4 digit LED display
Input resistance
of electrode within Giga Ohm range
sera CO2solenoid valve:
Total operating energy input 1.6 VA (Watts)
Max. Pressure load 5.5 bar (80 psi.)
Ambient temperature 0 – 50°C (32 – 122°F)
Hose connector 4/6 mm (0.16/0.24 in.,
internal/external
diameter)
Switchable socket:
Switching capacity max. 1,000 W
max. load 5A at 250 V~
* The socket for connecting the pH electrode (electrode plug) is
not moisture proof. Exposing this socket to moisture may
cause incorrect pH measuring values. This may lead to uncon-
trolled CO2release into the aquarium.
11. Spare parts and accessories:
sera pH measuring electrode (item No. 08921)
sera CO2solenoid valve (item No. 08030)
sera test solution pH 4.0 (item No. 08916)
sera test solution pH 7.0 (item No. 08923)
sera CO2hose 4/6 (item No. 08022)
sera non-return valve (item No. 08818)
Disposal of the unit:
Waste electrical and electronic equipment (WEEE)
must not get into domestic waste!
If ever the unit cannot be used anymore, the consumer
is legally obliged to hand in waste electrical and elec-
tronic equipment (WEEE) separately from domestic
waste, e.g. at a collection point of his community/his
district. This ensures that waste electrical and elec-
tronic equipment (WEEE) is expertly processed and
that negative effects to the environment are avoided.
Therefore electrical and electronic
equipment bears the following symbol:
Problem Possible cause Troubleshooting
CO2consumption too high Too strong aeration of the aquari-
um, no cover
Reduce CO2loss by reducing oxygen
supply
Tightening nut at adjustment wheel
of sera CO2pressure reducer has
become loose
Fasten tightening nut firmly by
hand. Do not use a wrench!
Threaded screw of pressure reducer
was over-tightened (display reads in
the RED area). Safety valve opens,
and CO2escapes with a hissing
sound
Loosen threaded screw
immediately. Open outlet valve
(adjustment wheel) to release the
built-up pressure. Close outlet valve
and tighten threaded screw very
slowly, so that operational pressure
is 1 bar (14.5 psi.)
Electrode shows discoloration
inside the shaft
Electrode has been contaminated
by other chemicals or medications
Replace
Fish are below surface and breath-
ing heavily or swimming abnormally
through the water
CO2gas having escaped from the
water is trapped below aquarium
cover
Provide better air circulation
pH value is too low in relation to
the carbonate hardness
Carry out a partial water change of
10 – 20%. Adjust to a higher pH
value after
Filter is not functioning properly Clean filter
Aquarium water is heavily burdened Carry out a partial water change
with gravel cleaning
Warranty:
When following the directions for use the seramic pH
Controller will perform reliably. We are liable for the
freedom from faults of our products only within legal
regulations beginning with the purchase date (excep-
tion: 12 months warranty on the pH electrode).
We are liable for complete flawlessness at delivery.
Should usual wear and tear occur by use as intended
by us, this is not considered a defect. Warranty claims
are also excluded in this case.
In every case of a defect we recommend that you con-
sult the specialized retailer where you purchased the
unit. He will be able to judge whether it is actually a
warranty case. In case of sending the unit to us we will
unnecessarily have to charge you for occurring costs.
Any liability because of contract breach is limited to
intent or gross negligence. sera will be liable in case of
slight negligence only in case of injuries to life, body
and health, in case of essential contractual obligations
and with binding liability according to the product lia-
bility code. In that case, the extent of liability is limited
to the replacement of contractually typically foresee-
able damages.
Please note the additional warranty information (*).
Important warranty addendum (*):
•A new pH electrode is one that has been manufactur-
ed a short time before. Electrodes will age even if
they are not in use. Depending on exact water com-
position, care and application range the expected
life span ranges from a few months up to several
years.
Warranty is void for electrodes that have been cor-
rupted by medications, colorants or chemicals, algae
deposits or dirt. Also, warranty is void in case of
storage in distilled water or test solutions, in case of
electrodes damaged by drying up and ones with
damaged cord, or broken electrodes, or ones that
have been destroyed by other improper use. Proper
use provided, however we grant 12 months warran-
ty on the electrode.
Solenoid valve: Water that has flowed-back into the
external solenoid valve (see section “Water flowing
back”) may destroy the valve. This is not a warranty
case. However, repair or replacement is possible. In
this case please consult your specialized retailer.
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149

Sera mic pH Controller Information For Use

Taper
Information For Use