Silvercrest 297903 Instructions For Use And Safety Notes

Catégorie
Unités de pression artérielle
Taper
Instructions For Use And Safety Notes
UPPER ARM BLOOD PRESSURE MONITOR
IAN 297903
OBERARM-
BLUTDRUCKMESSGERÄT
Gebrauchsanleitung und Sicherheitshinweise
BOVENARM-BL OEDDRUKMETER
Gebruikershandleiding en veiligheidsinstructies
TENSIOMÈTRE DE BRAS
Mode d‘emploi et consignes de sécurité
BLODTR YKSMÅLER TIL
OVERARMEN
Brugsvejledning og sikkerhedshenvisninger
UPPER ARM BLOOD PRESSURE
MONITOR
Instructions for Use and Safety Notes
Before reading, unfold both pages containing illustrations and familiarise yourself with all functions
of the device.
Før du læser, vend begge sidene med billeder frem og bliv bekendt med alle apparatets funktioner.
Avant de lire le mode d‘emploi, ouvrez la page contenant les illustrations et familiarisez-vous ensuite
avec toutes les fonctions de l‘appareil.
Vouw vóór het lezen de pagina met de afbeeldingen open en maak u vertrouwd met alle functies van het
apparaat.
Klappen Sie vor dem Lesen die Seite mit den Abbildungen aus und machen Sie sich anschließend mit
allen Funktionen des Gerätes vertraut.
GB / IE / NI Instructions for Use and Safety Notes Page 5
DK Brugsvejledning og sikkerhedshenvisninger Side 37
FR / BE Mode d‘emploi et consignes de sécurité Page 67
NL / BE Gebruikershandleiding en veiligheidsinstructies Pagina 99
DE / AT / CH Gebrauchsanleitung und Sicherheitshinweise Seite 131
C D
B
12
13
14
161718 1519
20
22
21
A
1
7
2 3 4
5
6
8
9
10
11
E F
G H
I J
5 GB/IE/NI
List of pictograms used ...............................................Page 6
Introduction .....................................................................Page 7
Intended use ....................................................................Page 8
Improper use .................................................................... Page 8
Parts description...............................................................Page 9
Scope of delivery .............................................................Page 10
Technical data .................................................................Page 10
Important Safety notes ...............................................Page 13
Battery safety information ...............................................Page 16
Initial use ........................................................................... Page 17
Inserting / Replacing batteries .........................................Page 17
App / web version of „HealthForYou“ ...........................Page 18
Configuring the date / time / Bluetooth
®
........................Page 18
Measuring blood pressure ........................................Page 20
Attaching the cuff ............................................................. Page 20
Adopting the correct posture ..........................................Page 21
Selecting a memory ......................................................... Page 21
Carrying out the blood pressure measurement .............Page 22
Transferring measurements via Bluetooth
®
.......Page 23
Evaluating measurements .........................................Page 25
Classification of measurement results ............................. Page 25
Saving, requesting and
deleting measurements ..............................................Page 27
Cleaning and care .........................................................Page 28
Storage ..............................................................................Page 29
Troubleshooting .............................................................Page 30
Disposal .............................................................................Page 31
Warranty / Service ........................................................Page 32
6 GB/IE/NI
List of pictograms used
Warning of risks of injury or health
hazards
Safety note related to possible damage to
the device / components
Safety notes
Instructions
Observe instructions for use
Direct current
Storage &
Transport
Permissable storage and transport
temperature and humidity
Operating
Permissible operating temperature and
humidity
Permissible storage, transport and
operating air pressure
Manufacturer
7 GB/IE/NI
Applied part, type BF
Serial number
0483
The CE mark certifies compliance with the
basic requirements of Medical Devices
Directive 93/42/EEC.
Improper disposal of batteries can harm the
environment!
IP21
Device protected against foreign matter
≥12.5 mm and against water falling
vertically
21
PAP
Dispose of the packaging and the blood
pressure monitor in an environmentally
friendly manner!
Upper Arm Blood Pressure Monitor
Introduction
Please make yourself familiar with the upper arm
blood pressure monitor before preparing it for
use or using it for the first time. Please carefully
read the following instructions for use and the important
safety notes. Failure to observe the notes may result in per-
sonal injury or property damage. The product must only be
8 GB/IE/NI
used as described in these instructions for use and for the
specified fields of application. Keep these instructions for
use in a safe place. If you pass the upper arm blood pres-
sure monitor on to anyone else, please ensure that you also
pass on all the documentation.
Intended use
This upper arm blood pressure monitor is intended to meas-
ure and monitor the arterial blood pressure values of adults
in a non-invasive way.
Using this device, you can quickly and easily measure your
blood pressure, save the measurements and display the
progression and average of these measurements. You are
warned in cases of pre-existing cardiac arrhythmia. The
values determined are classified and evaluated graphically.
Any use other than previously mentioned or any product
modification is prohibited and may result in injuries and / or
product damage. The manufacturer assumes no liability for
damage arising out of improper use.
The product is only intended for use in private environments
(at home).
Improper use
Do not use this product on newborns
and preeclampsia patients. We recommend consulting
your doctor before using the product if you are pregnant.
9 GB/IE/NI
The measurements determined by you are only intended
for your information - they do not replace a medical ex-
amination. Discuss the measurements with your doctor.
Do not self-diagnose or self-treat based on the measure-
ment results without consulting your attending physician.
Do not start new medication without consulting a doctor
and do not modify the type and / or dosage of current
medications.
The product may not be used in conjunction with a
high-frequency surgical unit.
Parts description
1
Cuff
2
Cuff tubing
3
Cuff plug
4
Display
5
Memory button M
6
Settings button SET
7
Function button -/+
8
START/STOP button
9
Scale for classifying measurement results
10
Connection for cuff plug
11
Battery compartment
Display indicators
12
Time and date
13
Systolic pressure
14
Diastolic pressure
10 GB/IE/NI
15
Pulse value determined
16
Symbol for cardiac arrhythmia
Symbol for pulse
17
Symbol for replace battery
18
Memory display: Average value (A), morning (AM),
evening (PM), number of the memory space
19
Classification of measurement results
20
Release air
21
User memory
22
Symbol for Bluetooth
®
transfer
Scope of delivery
1 Upper arm blood pressure monitor
1 Upper arm cuff (Material no. 163.243) with cuff tubing
4 Batteries 1.5 V Type AA
1 Instructions for use
1 Quick start guide
Technical data
Model no.: SBM 67
Measuring method: Oscillometric, non-invasive blood
pressure measurement on the upper
arm
Measurement range: Cuff pressure 0–300 mmHg,
systolic 50–250 mmHg, diastolic
30–200 mmHg, pulse 40–180
beats per minute
11 GB/IE/NI
Display accuracy: systolic ± 3 mmHg, diastolic
± 3 mmHg, pulse ± 5 % of the
displayed value
Measurement
uncertainty: max. permissible standard deviation
according to clinical testing: systolic
8 mmHg / diastolic 8 mmHg
Memory: 4 x 30 memory spaces
Dimensions: L 139 mm x W 103 mm x H 54 mm
Cuff: suitable for an arm circumference
between 22 and 36 cm
Weight: approx. 267 g (without batteries
and cuff)
Permissible
operating conditions: +5 °C to +40 °C, 15% to 93%
relative humidity (non-condensing)
Permissible storage
conditions: -25 °C to +70 °C, < 93% relative
humidity, 700-1060 hPa ambient
pressure
Power supply: 4 x 1.5 V AA batteries
Product expected
lifespan: 5 years
Battery life: Approx. 200 measurements, de-
pending on blood pressure level and
inflation pressure / Bluetooth
®
trans-
fer
Components: Instructions for use, 4 x 1.5 V AA,
batteries, storage pouch
12 GB/IE/NI
Classification: Internal supply, IP21, no AP or APG,
continuous operation, applied part
Type BF
Data transfer via
Bluetooth
®
wireless technology: The product uses Bluetooth
®
low
energy technology, frequency band
2.402 - 2.480 GHz, maximum
transmission power radiated in the
frequency band < 0.6 dBm, compati-
ble with Bluetooth
®
≥ 4.0 smart
phones / tablets
For a list of compatible smart phones,
information about the HealthForYou
app and software, as well as further
details about the devices, please
visit: www.healthforyou.lidl
System requirements
of the „HealthForYou“
web version: - MS Internet Explorer
- MS Edge
- Mozilla Firefox
- Google Chrome
- Apple Safari
(in the respective updated version)
13 GB/IE/NI
System requirements
of the „HealthForYou“
app iOS from Version ≥ 9.0, Android
TM
from Version ≥ 5.0, Bluetooth
®
≥ 4.0.
Technical specifications subject to change without notice
due to updates.
Important Safety
notes
This device is not intended to be used
by persons with limited physical, sensory or mental abili-
ties or lacking experience and / or knowledge unless
supervised or instructed on its use by an person respon-
sible for their safety. Children should be supervised to
ensure they do not play with the device.
Cardiovascular system diseases may result in incorrect
measurements and/or impairments to the device‘s
measurement accuracy. This is also the case when it
comes to low blood pressure, diabetes, circulatory prob-
lems and dysrhythmia, as well as chills and shaking.
Only use the product on individuals who have the
upper arm range stated for the product.
Ensure that the limb is not functionally impaired during
inflation.
Blood circulation should not be restricted by the blood
pressure measurement for an unnecessary amount of
time. Remove the cuff from the arm if the device mal-
functions.
14 GB/IE/NI
Avoid mechanically restricting, compressing or kinking
the cuff tubing.
Avoid sustained pressure to the cuff, as well as frequent
measurements. The resulting curtailing of the blood flow
can lead to injuries.
Ensure that the cuff is not placed on an arm whose
arteries or veins are undergoing medical treatment, i.e.
intravascular access or intravascular therapy or an
arteriovenous (A-V) shunt.
Do not place the cuff on individuals who have had a
mastectomy.
Do not place the cuff over wounds as this could lead to
further injuries.
Only place the cuff on the upper arm. Do not place the
cuff on other body parts.
Attention: The device may only be used in conjunction
with the original cuff provided.
Do not use rechargeable batteries.
If no button is pressed, the automatic shutoff will switch
off the blood pressure monitor within 1 minute to save
the batteries.
Attention! Potential damage to the device!
The blood pressure monitor is made up of
precision components and electronic compo-
nents. The accuracy of the measurements
and the service life of the device depend on
the device being used with a due amount of
care:
Protect the device from impacts, moisture, dirt, severe
temperature fluctuations and direct sunlight.
15 GB/IE/NI
Do not drop the device.
The use of the device may be limited in the presence of
electromagnetic disturbances. This could result in issues such
as error messages or the failure of the display/device.
Avoid using this device directly next to other devices or
stacked on top of other devices, as this could lead to
faulty operation. If, however, it is necessary to use the
device in the manner stated, this device as well as the
other devices must be monitored to ensure they are
working properly.
The use of accessories other than those specified or
provided by the manufacturer of this device can lead to
an increase in electromagnetic emissions or a decrease
in the device’s electromagnetic immunity; this can result
in faulty operation.
Failure to comply with the above can impair the perfor-
mance of the device.
Do not use the device in the vicinity of strong electro-
magnetic fields, keep it away from radio equipment
and mobile telephones.
Only use the cuff provided or an original replacement
cuff. Otherwise, measurements could be miscalculated.
Remove the batteries from the device if it is not used
over a longer period of time.
Routinely inspect the device to ensure the device is not
visibly damaged before use and the battery level is suf-
ficient. When in doubt, do not use and contact service
or an authorised retailer. Do not use additional parts
not recommended or sold as components by the manu-
facturer.
16 GB/IE/NI
Never open or repair the device or proper function cannot
be guaranteed. Non-compliance will void the warranty.
Please contact service or an authorised retailer for
repairs. However, before making a complaint, firstly
check the batteries and replace them if necessary.
Battery safety
information
DANGER TO LIFE! Keep batteries out of the reach of
children. Seek immediate medical attention if swallowed!
EXPLOSION HAZARD! Never recharge
disposable batteries. Never short-circuit and /
or open batteries. The battery may overheat,
ignite or explode.
Never throw batteries into fire or water.
Do not exert mechanical stress on batteries.
Risk of battery leakage
Avoid extreme conditions and temperatures which may
affect batteries, e.g. radiators / direct sunlight.
If batteries have leaked, avoid contact with skin, eyes
and mucous membranes with the chemicals! Flush im-
mediately the affected areas with fresh water and seek
medical attention!
WEAR PROTECTIVE GLOVES! Leaked or
damaged batteries can cause burns on con-
tact with the skin. Therefore wear suitable
safety gloves in this case.
17 GB/IE/NI
In the event of a battery leak, immediately remove the
batteries from the product to prevent damage.
Only use the same type of batteries. Do not mix old
and new batteries!
Remove the batteries if the product will not be used for
an extended period.
Risk of product damage
Only use the specified battery type!
Insert the batteries according to the polarity marking
(+) and (-) on the battery and the product.
Clean the contacts on the battery and inside the battery
compartment with a dry cloth before inserting the battery!
Immediately remove drained batteries from the product.
Do not use rechargeable batteries.
Initial use
Verify the parts listed in the scope of delivery are complete.
Remove all packaging material.
Inserting / Replacing batteries
Slide the battery cover off the battery compartment
11
(Fig. C).
Insert the four type 1.5V AA (Alkaline Type LR6) batter-
ies (with the correct polarity) into the device (Fig. C).
Please note the marking inside the battery compartment.
18 GB/IE/NI
Carefully close the battery cover on the battery com-
partment
11
.
Do not use rechargeable batteries.
Note: If the battery indicator
17
is displayed continu-
ously, measurement is not possible and you must replace
all of the batteries with new batteries. As soon as the
batteries have been removed from the device, the date
and time will be reset.
All display elements will be displayed briefly and „24h“
will flash on the display. Configure the date, time and
Bluetooth
®
(see „Configuring date / time / Bluetooth
®
“).
App / web version of
„HealthForYou“
Download the free app „HealthForYou“ from the Apple
App Store and Google Play.
Follow the installation instructions on the screen.
Alternatively, you can also visit the website
www.healthforyou.lidl. Here you will be
able to enter measurements and find
guidance for assessment.
Configuring the date /
time / Bluetooth
®
Configure the date, hour format and time. It is only in
this way that you will be able to correctly save these
19 GB/IE/NI
measurements with the date and time and request them
later on.
Configure the date, Bluetooth
®
and time as follows:
Insert the batteries, or press the SET button
6
for over
5 seconds for batteries that have already been inserted.
Configure the 12-hour or 24-hour mode using the +
7
button. Press the SET button
6
to confirm.
The year will flash.
Configure the year using the + button. Press the SET
button
6
to confirm.
The month will flash.
Configure the month using the + button. Press the SET
button
6
to confirm.
Configure the day, hour and minute consecutively as
described above. Press the SET
6
button to confirm
each entry.
The Bluetooth
®
symbol will be shown on the display.
„On“ or „Off“ will flash at the same time.
Using the function buttons „-/+“ choose whether you
want to activate („On“ flashes) or deactivate („Off
flashes“) Bluetooth
®
data transfer. Press the SET
button
6
to confirm.
If Bluetooth
®
is activated („On“) data transfer will begin
automatically after the measurement has been taken.
Note: The battery life is reduced by transfer via
Bluetooth
®
.
20 GB/IE/NI
Measuring blood pressure
Note: To guarantee that you will be able to compare
values adequately, always measure your blood pressure
at the same time of day. Rest for approx. 5 minutes
before every measurement!
If you wish to undertake multiple measurements on the
one person, wait for 5 minutes between taking each
measurement.
You should not eat, drink, smoke or be active in the
30 minutes before each measurement.
Repeat the measurement process if the measured values
seem incorrect.
Bring the device to room temperature before the meas-
urement.
Attaching the cuff
ATTENTION! The device may only be used in conjunction
with the original cuff provided. The cuff is suitable
for an
upper arm circumference of between 22 and 36
cm.
Place the cuff
1
on a bare upper left arm (Fig. D). The
blood flow of the arm should not be constricted by
clothing which is too tight, etc.
The cuff
1
should be placed on the upper arm in such
a way that the lower edge lies 2–3 cm over the crook
of the arm and the artery. The cuff tubing
2
points to
the centre of the palm.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164

Silvercrest 297903 Instructions For Use And Safety Notes

Catégorie
Unités de pression artérielle
Taper
Instructions For Use And Safety Notes

dans d''autres langues