Modern Forms PD-72128 Coliseo Mode d'emploi

Taper
Mode d'emploi
1
INSTALLATION INSTRUCTIONS

PD-72128

modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Jun. 2021
: To prevent electrical shock, ensure electricity has been turned o at the circuit breaker before beginning.
• Read all instructions before installing.
• System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
• Retain installation instructions for future maintenance reference.
: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern
Forms could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any
parts are damaged or missing.
: Coastal conditions may cause mineral and residue build-up on the xture. We recommend that customers in coastal
areas clean all external surfaces of the xture once every two weeks with a wet cloth.
: Pour éviter tout choc électrique, assurez-vous que le disjoncteur soit mis hors tension avant de commencer.
• Lisez toutes les instructions avant l’installation.
• Le système doit être installé par un électricien licensié conformément au code national de lélectricité (NEC), et également aux
règlements locaux.
• Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement
avec les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus
pour ce produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la
garantie. Veuillez contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
: Les conditions côtières peut causer une accumulation de minéraux et de résidue sur le luminaire. Nous recommendons
aux clients qui resident dans les zones côtières de nettoyer toutes les surfaces externes du luminaire une fois toutes les deux semaines avec
un chion humide.
Wire Connector
Qty: 5pcs+2 ExtraMounting Screw
Qty:1 ExtraWood Screw
Qty: 3pcs+1 Extra
B
ACDEF
Cap Screw
Qty:1 Extra
Alabaster
Qty: 64pcs+1 Extra
Plastic Anchor
Qty: 3pcs+1 Extra
2
INSTALLATION INSTRUCTIONS

PD-72128
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Jun. 2021
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760

1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.

3. Remove the cap screw(D) and cap from the xture.
4. Remove the mounting screw (B) and back plate from the xture.
5. Drill holes in the ceiling aligned with the key holes located in the mounting back plate, insert the plastic anchor (F).
6. Secure the mounting back plate to the junction box using standard junction box screws that comes with the junction box, fasten it to the
ceiling using wood screw (E) .
N o t e (i) using any other non-original-manufacturer provided junction box screw may result in safety issue;
(ii) The side of the mounting plate marked “GND” must face out.
7. Adjust the xture wire length by pushing the cable gripper on the canopy and pulling the wire as desired.
a) Retract the wires inside the canopy until the pendant is close to a desirable length prior to securing the xture in place.
retracting or extending excessive cable length through the cable gripper is not commended.
b) Shortening these cables without professional helps or electronic background is not advisable.Any modications to the
xture may result in voiding the warranty of the product.
8. If shortening the cable is needed, make sure to identify how the wires are being connected and label each wire clearly before
trimming/shortening(Fig.4).

Wire Connector
Canopy
Ground
Junction Box
Mounting Back Plate
White Wire
Black Wire
Junction Box Screw
Mounting Screw
Lamp Body
Safety Cords
Alabaster
(RPL-GLA-72128)
Cap
Cap Screw
Push up
Cable-gripper
Plastic Anchor
Wood Screw
Driver
D
A
B
C
E
F

Alabaster
(RPL-GLA-72128)
C
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)


1 3/8“1 3/4“
Ø6 3/4“
Ø5 1/8“
3
INSTALLATION INSTRUCTIONS

PD-72128
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. June. 2021
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760

9. Properly secure the safety cord to the bracket on mounting back plate to hang the xture temporarily in place and aid installation.
10. Connect the driver’s output wires to center cable as shown in Fig. 4, red to the center, and black to the bare, make sure that wire
connectors (A) are secured. Then tuck them inside the canopy.
11. Connect the driver’s input wires to junction box wires as shown in Fig. 3, making sure that all wire connectors (A) are secured. If your
outlet box has a green or bare copper ground wire, connect the xtures ground wire to it. Otherwise, connect the xture’s ground wire
directly to the back plate using the GND screw provided. After wires are connected, tuck them carefully inside the junction box.
12. Secure the xture by mounting the canopy onto the back plate. Turn and rotate the canopy in the direction of the arrow until it stops (Fig1).
13. Fasten the canopy to the mounting back plate with mounting screws(B).

14. Insert the alabaster panels (C) into the slot from the bottom up (Fig.1), so it sits along the bottom frame of the xture and side it over to
your desired position .
15. The last piece of alabaster is not easy to be inserted from the bottom, and should be insert it from the top slot(Fig.2).
Alabaster panels is fragile, please handle it with care.
16. When complete, place the cap over the xture and secure with cap screws(D).

17. This xture features electronic low voltage (ELV or TRAIC) or 0-10V dimming capabilities. See notes below for specic dimming wires
information.
18. To utilize ELV or TRAIC dimming: use wires black (hot), white (neutral) and bare copper ground wire (ground).
19. To utilize 0-10V dimming: use wire purple (dim+), pink or gray (dim-), black (hot), white (neutral) and bare copper ground wire (ground).
: Make sure to connect 0-10V prior to power-up the xture in order to allow the 0-10V dimming to function properly.

Purple - Dim+
Pink or Gray - Dim-
White - Neutral
Black - Hot
Red +
Black -
Center +
Bare -
Canopy
Output
Input
Driver
Center - To Driver+(Red)
Bare - To Driver-(Black)
Center - To Driver+(Red)
Bare - To Driver-(Black)
Label
  • Page 1 1
  • Page 2 2
  • Page 3 3

Modern Forms PD-72128 Coliseo Mode d'emploi

Taper
Mode d'emploi