1
INSTALLATION INSTRUCTIONS
642 - LED Pendant
PD-64256
A
BC D
Wire Connector
Qty: 3pcs+1 Extra
Mounting Screw
Qty: 1 Extra
Wood Screw
Qty: 2pcs+1 Extra
Plastic Anchor
Qty: 2pcs+1Extra
• Read all instructions before installing.
• System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
• Retain installation instructions for future maintenance reference.
All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern
Forms could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any
parts are damaged or missing.
Pour éviter tout choc électrique, assurez-vous que le disjoncteur soit mis hors tension avant de commencer.
• Lisez toutes les instructions avant l’installation.
• Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également aux
règlements locaux.
• Lors de la manipulation du luminaire, nappuyez pas sur les LED. Tenez-le uniquement par la base.
Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement
avec les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus
pour ce produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la
garantie. Veuillez contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
Les conditions côtières peut causer une accumulation de minéraux et de résidue sur le luminaire. Nous recommendons
aux clients qui resident dans les zones côtières de nettoyer toutes les surfaces externes du luminaire une fois toutes les deux semaines avec
Phone (800) 526.2588
Fax (800) 526.2585
44 Harbor Park Drive
Port Washington, NY 11050
1600 Distribution Ct
Lithia Springs, GA 30122
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Nov. 2021
PREPARATION
1. Shut o the power at the circuit breaker and
remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out
all the parts on a clear area. Be careful not to
lose any small parts necessary for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screw (B) from the
mounting plate.
4. Drill holes in the wall aligned with the key
holes located in the mounting plate. Insert
the plastic anchors (C).
5. Adjust the xture wire length by pushing the
cable gripper on the canopy and pulling the
wire as desired.
a) Retract these wires close to a desirable
length to within the canopy before securing
the xture in place.
Note: retracting or extending excessive cable
length through the cable gripper is not
recommended.
b) Warning: Shortening these cables without
professional helps or electronic background is
not advisable. Any modications to the
xture may result in voiding the warranty of the product.
6. Secure the mounting plate to the junction box using the screws provided with the junction box. Fasten the back plate to the wall with
the plastic anchors using the wood screws (D) provided.
Note: (i)using any other non-original-manufacturer provided junction box screw may result in safety issue;
(ii) The side of the mounting plate marked GND” must face out.
CONNECTING THE WIRES (Fig. 2)
7. Properly secure the safety cord to the bracket on the mounting back plate to temporarily hang the xture in place and aid installation.
8. Connect the Driver input wires to junction box as shown in Fig .2. Making sure that all wire connectors (A) are secured. If your
outlet box has a green or bare copper ground wire, connect the xture’s ground wire to it. Otherwise, connect the xtures ground
wire directly to the back plate using the GND screw provided. After wires are connected, tuck them carefully inside the junction box.
COMPLETING THE INSTALLATION
9. Secure the xture by mounting the canopy to the mounting plate. Slide the canopy in the direction of the notch until it latches in place.
Secure the xture to the mounting plate using the mounting screw(B).
DIMMING WIRING INFORMATION (Fig. 3)
10. This xture features electronic low voltage (ELV or TRIAC) or 0-10V dimming capabilities. See notes below for specic dimming wires
information.
11. To utilize ELV or TRIAC dimming: use wires black (hot), white (neutral) and bare copper ground wire (ground).
12. To utilize 0-10V dimming: use wire purple (dim+), gray or pink (dim-), black (hot), white (neutral) and bare copper ground wire (ground).
NOTE: Make sure to connect 0-10V prior to power-up the xture in order to allow the 0-10V dimmer to function properly.
2
INSTALLATION INSTRUCTIONS
642 - LED Pendant
PD-64256
White - Neutral
Black - Hot
Purple - Dim+
Pink or gray - Dim-
Red - Fixture+
Black - Fixture-
Phone (800) 526.2588
Fax (800) 526.2585
44 Harbor Park Drive
Port Washington, NY 11050
1600 Distribution Ct
Lithia Springs, GA 30122
1750 Archibald Avenue
Ontario, CA 91760
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Nov. 2021
Wire Connector
Junction Box
A
Ground Wire
Mouting Plate
Plastic Anchor
C
Junction Box Screw
Wood Screw
D
Driver
Canopy
Wire
Push up
Cable gripper
Fixture
Mounting Screw
B
13
4
11
8
Mouting Plate Dimensions
41
2
47
8
41
8
Instruction: Adjust the xture wire
length by pushing the cable
gripper on the canopy and
pulling the wire as desired.
Safety Cord
  • Page 1 1
  • Page 2 2

Modern Forms PD-64256 Sydney Mode d'emploi

Catégorie
Mur
Taper
Mode d'emploi

dans d''autres langues