Extron DTP T UWP 4K 232 D Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

User Guide
DTP T UWP 4K D Series
HDMI Transmitters
HDMI Twisted Pair Extender Transmitters
68-3157-01 Rev.
B
01 19
Safety Instructions
Safety Instructions • English
WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within
the product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind und
die einen elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in
der im Lieferumfang enthaltenen Dokumentation besonders wichtige
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad
de Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du
produit d’une tension électrique dangereuse susceptible de provoquer
un choc électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf.
68-290-01, sur le site Extron, www.extron.com.
Istruzioni di sicurezza • Italiano
AVVISO: Questo simbolo, ,quando viene utilizzato il prodotto, serve
ad avvisare l’utente della presenza di tensioni pericolose non isolate
all’interno del prodotto, che può presentare un rischio di scosse
elettriche.
ATTENTZIONE: Questo simbolo, , quando viene utilizzato il
prodotto, serve ad avvisare l’utente di importanti istruzioni di uso e
manutenzione (assistenza) nella letteratura fornita con l’apparecchiatura.
Per informazioni sulle linee guida di sicurezza, adempimenti normativi,
compatibilità EMI/EMF, accessibilità e argomenti correlati, vedere la sicurezza
di Extron e Regulatory Compliance Guide, parte numero
68-290-01, sul sito Web Extron, www.extron.com.
Instrukcje bezpieczeństwa • Polska
OSTRZEŻENIE: Ten symbol, , gdy używany na produkt, ma na celu
poinformować użytkownika o obecności izolowanego i niebezpiecznego
napięcia wewnątrz obudowy produktu, który może stanowić zagrenie
porażenia prądem elektrycznym.
UWAGI: Ten symbol, , gdy używany na produkt, jest przeznaczony do
ostrzegania użytkownika ważne operacyjne oraz instrukcje konserwacji
(obsługi) w literaturze, wyposażone w sprzęt.
Informacji na temat wytycznych w sprawie bezpieczeństwa, regulacji
wzajemnej zgodności, zgodność EMI/EMF, dostępności i Tematy pokrewne,
zobacz Extron bezpieczeństwa i regulacyjnego zgodności przewodnik, część
numer 68-290-01, na stronie internetowej Extron, www.extron.com.
Инструкция по технике безопасности Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии неизолированного опасного напряжения
внутри корпуса продукта, которое может привести к поражению электрическим
током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: ,
www.extron.com, номер по каталогу - 68-290-01.
安全说明 简体中文
警告 产品上的这个标志意在警告用户该产品机壳内有暴露的危险 电压,
险。
注意 产品上的这个标志意在提示用户设备随附的用户手册中有
重要的操作和维护(维修说明
关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍
使用的特性等相关内容,敬请访问 Extron 网站 , www.extron.com,参见
Extron 安全规范指南,产品编号 68-290-01
安全記事 • 繁體中文
警告: 若產品上使用此號,是為了提醒使用者產品機殼內存在著
可能會導致觸電之風險的未絕緣危險電壓
注意 品上使用此符號,是為提醒使用備隨附用戶手冊中
重要的操作和維(維修説明
有關安全性指導方針法規遵EMI/EMF 相容存取範圍和相主題的詳細
訊,請瀏覽 Extron 網站:www.extron.com然後參《Extron 安全性與法規
守手冊準則編號 68-290-01
安全上の注意
日本語
警告: この 製品上に表示されている場合は、筐体内に絶縁され
いない高電圧が流れ、電の危険があるを示ています
意:この が製上に表示されている場合は、の取明書に
されている重作と保()のについてユーザー
を喚起するものです
安全上の注意、法規厳守、EMI/EMF適合性、その他の関連項
スト イト www.extron.com よ り Extron Safety
and Regulatory Compliance Guide』 ( P/N 68-290-01) をご覧ださい。
안전 지침 • 한국어
경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합
니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에
대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및
규제 준수 안내서, 68-290-01 조항을 참조하십시오.
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause interference. This interference must be corrected at the expense of the user.
ATTENTION: The Twisted Pair Extension technology works with shielded twisted pair
(STP) cables only. To ensure FCC Class A and CE compliance, STP cables and STP
connectors are also required.
For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the “Extron Safety and
Regulatory Compliance Guide” on the Extron website.
Copyright
© 2017
-2019 Extron Electronics. All rights reserved.
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks
®
, registered service marks
(SM)
, and trademarks
(TM)
are the property of RGB Systems, Inc. or
Extron Electronics (see the current list of trademarks on the Terms of Use page at www.extron.com):
Registered Trademarks
(®)
Extron, Cable Cubby, ControlScript, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, Flat Field, FlexOS, Global Configurator,
GlobalScripter, GlobalViewer, Hideaway, HyperLane, IPIntercom, IPLink, KeyMinder, LinkLicense, LockIt, MediaLink, MediaPort, NetPA,
PlenumVault, PoleVault, PowerCage, PURE3, Quantum, Show Me, SoundField, SpeedMount, SpeedSwitch, SystemINTEGRATOR,
TeamWork, TouchLink, V-Lock, VideoLounge, VN-Matrix, VoiceLift, WallVault, WindoWall, XTP, XTPSystems, and ZipClip
Registered Service Mark
(SM)
: S3 Service Support Solutions
Trademarks
(
)
AAP, AFL (Accu-RateFrameLock), ADSP(Advanced Digital Sync Processing), Auto-Image, CableCover, CDRS(ClassD Ripple
Suppression), Codec Connect, DDSP(Digital Display Sync Processing), DMI (DynamicMotionInterpolation), DriverConfigurator,
DSPConfigurator, DSVP(Digital Sync Validation Processing), eLink, EQIP, Everlast, FastBite, FOX, FOXBOX, IP Intercom HelpDesk,
MAAP, MicroDigital, Opti-Torque, ProDSP, QS-FPC(QuickSwitch Front Panel Controller), Room Agent, Scope-Trigger, ShareLink, SIS,
SimpleInstructionSet, Skew-Free, SpeedNav, StudioStation, Triple-Action Switching, True4K, Vector™ 4K , WebShare, XTRA, and
ZipCaddy
Conventions Used in this Guide
Notifications
The following notifications are used in this guide:
CAUTION: Risk of minor personal injury.
ATTENTION : Risque de blessuremineure.
ATTENTION:
Risk of property damage.
Risque de dommages matériels.
NOTE: A note draws attention to important information.
Software Commands
Commands are written in the fonts shown here:
^AR Merge Scene,,Op1 scene 1,1 ^B 51 ^W^C
[01] R 0004 00300 00400 00800 00600 [02] 35 [17] [03]
E X! *X1&* X2)* X2#* X2! CE}
NOTE: For commands and examples of computer or device responses mentioned
in this guide, the character “0” is used for the number zero and “O” is the capital
letter “o.”
Computer responses and directory paths that do not have variables are written in the font
shown here:
Reply from 208.132.180.48: bytes=32 times=2ms TTL=32
C:\Program Files\Extron
Variables are written in slanted form as shown here:
ping xxx.xxx.xxx.xxx —t
SOH R Data STX Command ETB ETX
Selectable items, such as menu names, menu options, buttons, tabs, and field names are
written in the font shown here:
From the File menu, select New.
Click the OK button.
Specifications Availability
Product specifications are available on the Extron website, www.extron.com.
Extron Glossary of Terms
A glossary of terms is available at http://www.extron.com/technology/glossary.aspx.
viExtron DTP T UWP 4K D Series • Contents
Contents
Introduction............................................................ 1
About this Guide ................................................. 1
About the DTP T UWP 4K D Extenders .............. 1
Twisted Pair Cable Advantages ....................... 2
Control Communications ................................ 2
Transmission Distance .................................... 2
Features ............................................................. 2
Installation and Operation .................................. 3
Mounting the Transmitter .................................... 3
UL and Safety Guidelines ................................ 3
Site Preparation and Wall Box Installation ....... 4
Mud Ring Installation ...................................... 5
Final Installation .............................................. 6
DTP T UWP 4K D Connections .......................... 6
Front Panel ..................................................... 6
Rear Panel ...................................................... 7
Twisted Pair Recommendations for DTP
Communication ................................................. 8
Power Supply Wiring .......................................... 9
RS-232 Connector Wiring ................................ 10
Remote RS-232 and Contact Closure
Connector ................................................... 10
Over DTP RS-232 Connector ....................... 10
Operation ......................................................... 11
Transmitter LEDs .......................................... 11
System Operation ......................................... 12
Audio Configuration ...................................... 12
Remote Control ................................................... 13
Contact Closure Control ................................... 13
Simple Instruction Set Control .......................... 13
Host-to-Extender Communications ............... 13
Extender-Initiated Messages ......................... 13
Error Responses ........................................... 14
Timeout ........................................................ 14
Using the Command and Response Table .... 14
Command and Response Table for SIS
Commands ................................................. 16
Reference Information ...................................... 20
Configuring the Transmitter with the Extron
PCS Software .................................................. 20
Downloading and Installing PCS ................... 20
Using PCS with the DTP T UWP 4K D
Series Transmitters ...................................... 21
Updating the Device Firmware ...................... 26
Decorator-Style Wallplate Template
Dimensions ..................................................... 30
Extron DTP T UWP 4K D Series • Introduction 1
Introduction
About this Guide
About the DTP T UWP 4K D Extenders
Features
About this Guide
This guide provides instructions for experienced, professional installers to install, operate,
and configure the Extron DTP T UWP 4K D series of High-Definition Multimedia Interface
(HDMI
®
) and VGA Extenders.
Terms Used in this Guide
The terms “extender” and “transmitter” are used interchangeably in this guide to refer to all
of the DTP T UWP 4K D models.
About the and DTP T UWP 4K D Extenders
The Extron DTP T UWP 4K 232 D and DTP T UWP 4K 332 D extenders are a series
of HDMI and VGA transmitters (see figure 1) that are housed in enclosures that can be
mounted in Underwriters Laboratories (UL) standard wall boxes with decorator-style
faceplates. Paired with a compatible DTP 230 or 330 receiver, they extend the usable
distance of HDMI digital video, VGA analog video, and RS-232 control signals over one
shielded twisted pair (STP) cable. The extenders also route and embed audio.
TLP 1000T
V
IPCP 505
IN1608
DTP HDMI 230 Rx
Projector
100-240V ~ -- A MAX
1
2
CONFIGURABLE
HDMI
HDMI
5
6
7
8
C
RS-232 IR
RS-232 IR
Tx Rx Tx RxG
Tx Rx Tx RxG
Tx Rx Tx RxG
HDMI
A
B
3
4
INPUTS
OUTPUTS
Tx Rx
RS-232
G
LAN
2x25W(8Ω)/2x50W(4Ω)
RESET
AUDIO INPUTS
OUTPUTS
REMOTE
LL1R R
L2
R
L
3
R
CLASS 2 WIRING
L4
R
L5R
+48V
+48V
12
LR
VARIABLE
IN1608 SA
2
MIC/LINE
L6
R
SIG LINK
DTP IN
SIG LINK
DTP IN
SIG LINK
DTP OUT
50/60 Hz
RS-232 IR
OVER DTP
OVER DTP
OVER DTP
AMPLIFIED OUTPUT
VOLUME
SCALING PRESENTATION SWITCHER
IN1608
INPUTS
1
HDCP
SIGNAL
OUTPUTS
ENTER
MENU
E
2 3 4 5 6 7 8 A B C
INPUTS
1 2 3 4 5 6 7 8
CONFIG
Extron
DTP T UWP 4K 232 D Tx
Transmitter
Ethernet
Network
LR
POWER
12V
0.7A MAX
AUDIO
SIG LINK
DTP IN
OUTPUTS
XTP DTP 24 Cable
230'
HDMI
12345678
100
LINK
ACT
COM
IR/S
TX
RX
TX
RX
RTS
CTS
R
5
1
6
2
7
3
8
4
RELAY
FLEX
I/O
5
1
6
2
3
1
4
2
eBUS
ACT LIMIT
OVER
SWITCHED
12VDC
3
1
4
OVER
2
LIMIT
IR
7
3
8
4
IPCP 505
AUTO SW
CONFIG
HDMI IN
AUDIO IN
HDCP
1
AUDIO IN
VGA IN
Figure 1. A Typical Transmitter and Receiver Application
DTP T UWP 4K D systems consist of a transmitter (Tx) and a receiver (Rx). The transmitters
and corresponding compatible receivers are sold separately. Each purchased transmitter is
shipped with a single external desktop 12 VDC power supply that accepts 100 to 240 VAC,
50-60 Hz input. A single power supply connected to either the transmitter or a compatible
receiver can power both units through the twisted pair cable that links the units.
Extron DTP T UWP 4K D Series • Introduction 2
Twisted Pair Cable Advantages
Twisted pair cable is much smaller, lighter, more flexible, and less expensive than coaxial
or HDMI cable. These transmitter and receiver twisted pair (TP) products make cable runs
simpler and less cumbersome. Termination of the cable with RJ-45 connectors is simple,
quick, and economical (see Twisted Pair Recommendations for DTP Communication
on page 8 for more information).
NOTE: Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201
cable to link the transmitter and receiver. The DTP T UWP 4K D series does not work
properly with these cables.
Control Communications
The RS-232 communications are pass-through only. The transmitter and receiver do not
generate or respond to these signals.
Transmission Distance
The maximum transmission distance is determined by the resolution of the signal and the
twisted pair cable, graphics card, and display used in the system.
DTP T UWP 4K 232 D transmitters can transmit 720p, 1080i or 1080p HDTV video,
and 4K signals up to 230 feet (70 meters) over STP cable.
DTP T UWP 4K 332 D transmitters can transmit 720p, 1080i or 1080p HDTV video,
and 4K signals up to 330 feet (100 meters) over STP cable.
Features
Transmits HDMI or VGA signals over one STP cable — Twisted pair cables provide an
economical, easily installed cable solution.
Supports computer and video resolutions up to 4K
Supports DDC and HDCP transmission — The transmitters fully support long distance
transmission of the DDC and HDCP signals.
Control communications pass-through — Bidirectional RS-232 control signals can be
transmitted alongside the HDMI signal, so that the remote display can be controlled without
the need for additional cabling.
Analog stereo audio embedding — Analog stereo audio signals can be selectively
embedded onto the digital video output signal and transported over DTP. The HDMI inputs
can be set to pass the embedded digital audio, embed the analog audio, or to automatically
embed the analog audio when no digital audio is detected.
External 100 VAC to 240 VAC, 50-60 Hz, international power supply — Included with
transmitters.
Remote powering of the transmitter or receiver — Only one power supply is necessary
to power both devices.
Extron DTP T UWP 4K D Series • Installation and Operation 3
Installation and
Operation
This section describes the installation and the operation of the extenders, including:
Mounting the Transmitter
DTP T UWP 4K D Connections
Twisted Pair Recommendations for DTP Communication
Power Supply Wiring
RS-232 Connector Wiring
Operation
Mounting the Transmitter
ATTENTION:
Installation and service must be performed by authorized personnel.
L’installation et l’entretien doivent être effectués par le personnel autorisé
uniquement.
The unit must be installed in accordance with the National Electrical Code and with
local electrical and safety codes.
L’unité doit être installée conformément au National Electric Code et aux normes
électriques et de sécurité locales.
The transmitters can be installed in a two-gang electrical wall box, or with a mud ring with a
decorator-style wallplate cover (supplied).
UL and Safety Guidelines
The following UL guidelines pertain to the installation of the decorator-style wallplate
transmitters into a wall or furniture.
These units are not to be connected to a centralized DC power source or used beyond
their rated voltage range.
These units must be installed in UL-listed wall boxes.
These units must be installed in a UL-listed junction box with a UL-listed faceplate.
This product is intended to be supplied by a power source marked “Class 2” or “LPS”
rated 12 VDC, minimum 1.0 A
Extron DTP T UWP 4K D Series • Installation and Operation 4
Site Preparation and Wall Box Installation
Choose a location that allows cable runs without interference. Allow enough depth for both
the wall box and the cables. Install the cables into the wall, furniture, or conduits before
installing the wallplate.
NOTE: The extender units are very deep and have connectors on the back side. Extron
recommends a 2-gang wall box that has a depth of at least 3.0 inches (7.6 cm) to
accommodate the connectors and cables.
To install a new wall box, perform steps 1 through 9. If a suitable wall box is already
installed, perform steps 6 through 9 on the next page. UL listed wall boxes are
recommended.
1. If a wall box is not available to use for a template, use the Decorator-Style Wallplate
Template Dimensions on page 30 to create a template. If installing directly into
furniture, cut out the center portion of the template.
2. Place the wall box (or the full size template) against the installation surface, and mark
the opening guidelines.
3. Cut out the material from the marked area.
4. Insert the wall box into the opening. The rear connectors on the box or wallplate should
fit easily into the opening. Enlarge or smooth the edges of the opening if needed.
5. Secure the wall box with nails or screws, leaving the front edge flush with the outer wall
or furniture surface (see figure 2).
NOTES:
If attaching the wall box to wood, use four #8 or #10 screws or 10-penny
nails. A minimum of 0.5 inch (1.3 cm) of screw thread must penetrate the
wood.
If attaching the wall box to metal studs or furniture, use four #8 or #10
self-tapping sheet metal screws or machine bolts with matching nuts.
Extron
DTP T UWP 4K 332 D
Signal Output
Cable
Cable
Clamp
Decorator-Style Faceplate
Screws or
Nails
W
all opening is
flush with edge of box.
Wall Stud
UTO SW
CONFIG
HDMI IN
AUDIO IN
DCP
1
AUDIO IN
VGA IN
Figure 2. Installing the Wall Box and Mounting the Unit
Extron DTP T UWP 4K D Series • Installation and Operation 5
6. Feed the twisted pair cables and, if applicable, the power cables through the opening
and through the wall box punch-out holes, securing them with cable clamps to provide
strain relief.
NOTES:
In order to fit in the wall box, the twisted pair cables and RJ-45 connectors
should not have a boot installed.
One power supply can power both the transmitter and the receiver, so only
one unit needs a power supply (see Power Supply Wiring on page 9).
7. Trim back and insulate exposed cable shields with heat shrink to reduce the chance of
short circuits.
To prevent short circuits, the outer foil shield can be cut back to the point where the
cable exits the cable clamp.
8. Connect the cables to the rear of the unit (see Rear Panel on page 7 for connector
details).
9. Connect front panel devices (see Front Panel on page 6 for connector details), restore
the power supply, and test the transmitter and receiver system. Make any cabling
adjustments before final installation, as the cables will be inaccessible afterwards.
Mud Ring Installation
1. Using the mud ring as a guide, mark the edges and cut out the material within the
marked area.
2. Insert the mud ring into the opening, rotate and secure the locking arms with the
supplied screws shown in figure 3.
3. Follow steps 6 through 9 of “Site Preparation and Wall Box Installation” above and
Final Installation on the next page.
Wall Mounting
Mudring
Wall
Figure 3. Installing the Mud Ring
Extron DTP T UWP 4K D Series • Installation and Operation 6
Final Installation
After testing and making any adjustments, do the following:
1. At the power outlet, unplug the power supply.
NOTE: One power supply can power both the transmitter and the receiver (see
Power Supply Wiring on page 9).
2. Mount the transmitter into the wall box or mud ring and attach the supplied
decorator-style faceplate to the unit (see figure 2 on page 4).
3. At the power outlet, reconnect the power supply. This powers up both units.
DTP T UWP 4K D Connections
Front Panel
AUTO SW
CONFIG
IR OUT
HDMI IN
AUDIO IN
G
S
HDCP
1
2
HDMI IN
AUDIO IN
E
DTP T HWP D
Front Panel
A
B
B
A
E
D
AUTO SW
CONFIG
HDMI IN
AUDIO IN
HDCP
1
AUDIO IN
VGA IN
E
DTP T UWP 4K D
Front Panel
A
A
B
C
D
Figure 4. DTP T UWP 4K D Front Panel Connectors
A Audio input connector — Connect an unbalanced stereo audio source to this 3.5 mm
mini stereo jack (see Audio Configuration on page 12 for embedded audio details).
B HDMI input connector — Connect an HDMI cable between this port and the HDMI
output port of the digital video source.
C VGA input connector — Connect a VGA cable between this port and the output port
of the video source.
D Mini USB port — Connect a male USB Mini-B cable to this port for SIS and PCS
configuration and firmware updates.
Extron DTP T UWP 4K D Series • Installation and Operation 7
Rear Panel
Reset
DTP OUTREMOTEOVER
DTP
SIG LINK
RS-232
CONTACT
DTP T UWP 232 D
Tx Rx
Tx Rx G
POWER
12V
A MAX
0.9
+–
G1 2
DTP T HWP/UWP 232/332 D
Rear Panel
F
A
B
C
E
D
Figure 5. DTP T UWP 4K D Rear Panel Connectors
A DC power input connector — Plug the included external 12 VDC power supply into
either this 2-pole connector (see Power Supply Wiring on page 9 to wire the power
connector) or the power input connector on the receiver (see the user guide of your
receiver for more information).
B Over DTP control port — Connect an RS-232 device to this 3-pole, 3.5 mm captive
screw connector for pass-through RS-232 control (see RS-232 Connector Wiring on
page 10 to properly wire the RS-232 connector).
C Remote (RS-232 and contact closure) control port — Connect an RS-232 device,
contact closure device, or both to this 5-pole, 3.5 mm captive screw connector to
control switching on the unit (see RS-232 Connector Wiring on page 10 to properly
wire the Remote connector).
RS-232 — To control the unit through this port, connect an RS-232 device and
configure it as follows: 9600 baud rate, 8 data bits, 1 stop bit, no parity.
Contact — Momentarily short pin 1 or 2 to ground (G) to select the corresponding
input.
D Grounding screw — Connect a grounding wire from this screw to the gang box
chassis to safely ground the unit.
E DTP Out port — Connect one end of the twisted pair cable to the RJ-45 connector on
the transmitter (see Twisted Pair Recommendations for DTP Communication on
the next page to properly wire the RJ-45 connectors). Connect the opposite end of the
cable to the appropriate receiver.
ATTENTION:
Do not connect these outputs to a telecommunications or computer data
network.
Ne connectez pas ces appareils à des données informatiques ou à un réseau
de télécommunications.
F Reset button — To perform a factory reset, use a small screwdriver to press and hold
the recessed button for 6 seconds while the extender is running.
Extron DTP T UWP 4K D Series • Installation and Operation 8
Twisted Pair Recommendations for DTP Communication
Use the following pin configurations for both ends of the shielded twisted pair cables.
5
Pin
1
2
3
6
7
8
4
Wire color
White-green
Green
White-orange
White-blue
Orange
White-brown
Brown
Blue
TIA/EIA
T568-B
TP Wires
12345678
Pins:
Figure 6. Twisted Pair Cable Configuration
Supported Cables
The extenders are compatible with shielded twisted pair cable (F/UTP, SF/UTP, and S/FTP).
ATTENTION:
Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or
STP201 cable to link the device with DTP transmitters or receivers.
N’utilisez pas le câble AV Skew-FreeUTP version améliorée UTP23SF
d’Extron ou le câble STP201 pour relier le appareil avec les émetteurs ou les
récepteurs DTP.
Cable Recommendations
Extron recommends using the following practices to achieve full transmission distances and
reduce transmission errors.
Use the following Extron XTP DTP 24 SF/UTP cables and connectors for the best
performance:
XTP DTP 24/1000 Non-Plenum 1000’ (305 m) spool 22-236-03
XTP DTP 24P/1000 Plenum 1000’ (305 m) spool 22-235-03
XTP DTP 24 Plug Package of 10 101-005-02
If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
Terminate cables with shielded connectors to the TIA/EIA-T568B standard.
Limit the use of more than two pass-through points, which may include patch points,
punch down connectors, couplers, and power injectors. If these pass-through points
are required, use shielded couplers and punch down connectors.
NOTE: When using shielded twisted pair cable in bundles or conduits, consider the
following:
Do not exceed 40% fill capacity in conduits.
Do not comb the cable for the first 20 meters, where cables are straightened,
aligned, and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.
Separate twisted pair cables from AC power cables.
Extron DTP T UWP 4K D Series • Installation and Operation 9
Power Supply Wiring
NOTES:
Only one power supply is required for both the transmitter and receiver. A single
power supply connected to either unit in the pair powers both units.
A power supply is included with each individually-packaged transmitter.
Do not tin the power supply leads before installing them in the direct insertion
connector. Tinned wires are not as secure in the connectors and could be pulled
out.
Figure 7 shows how to wire the connector.
SECTION A–A
AA
Power Supply
Captive Screw
Ridges
Smooth
3/16"
(5 mm) Max.
Connector
Output Cord
Figure 7. Power Connector Wiring
CAUTION: The wires must be kept separate while the power supply is plugged in.
Remove power before wiring.
ATTENTION : Les deux cordons d’alimentation doivent être tenus à l’écart l’un de
l’autre quand l’alimentation est branchée. Couper l’alimentation avant de faire
l’installation électrique.
ATTENTION:
Always use a power supply supplied and or specified by Extron. Use of an
unauthorized power supply voids all regulatory compliance certification and may
cause damage to the supply and the end product.
Utilisez toujours une source d’alimentation fournie ou recommandée par Extron.
L’utilisation d’une source d’alimentation non autorisée annule toute conformité
réglementaire et peut endommager la source d’alimentation ainsi que le produit
final.
The installation must always be in accordance with the applicable provisions of
National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical
Code part 1, section 16. The power supply shall not be permanently fixed to
building structure or similar structure.
Cette installation doit toujours être en accord avec les mesures qui s’applique
au National Electrical Code ANSI/NFPA70, article725, et au Canadian Electrical
Code, partie1, section16. La source d’alimentation ne devra pas être fixée de
façon permanente à une structure de bâtiment ou à une structure similaire.
Extron DTP T UWP 4K D Series • Installation and Operation 10
Power supply voltage polarity is critical. Incorrect voltage polarity can damage
the power supply and the unit. The ridges on the side of the cord (see figure 7 on
previous page) identify the power cord negative lead.
La polarité de la source d’alimentation est primordiale. Une polarité incorrecte
pourrait endommager la source d’alimentation et l’unité. Les stries sur le côté du
cordon permettent de repérer le pôle négatif du cordon d’alimentation.
To verify the polarity before connection, plug in the power supply with no load and
check the output with a voltmeter.
Pour vérifier la polarité avant la connexion, brancher l’alimentation hors charge et
mesurer sa sortie avec un voltmètre.
The length of the exposed (stripped) copper wires is important.
The ideal length is 3/16 inch (5 mm). Longer bare wires can short together.
Shorter wires are not as secure in the connectors and could be pulled out.
La longueur des câbles exposés est primordiale lorsque l’on entreprend de les
dénuder. La longueur idéale est de 5mm (3/16inches). S’ils sont un peu plus
longs, les câbles exposés pourraient se toucher et provoquer un court circuit. S’ils
sont un peu plus courts, ils pourraient sortir, même s’ils sont attachés par les vis
captives.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air
handling spaces or in wall cavities.
Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une
utilisation dans les espaces d’aération ou dans les cavités murales.
RS-232 Connector Wiring
NOTE: Do not tin the wires before installing them in the direct insertion connector.
Tinned wires are not as secure in the connectors and could be pulled out.
Remote RS-232 and Contact Closure Connector
Wire the rear Remote RS-232 and contact closure connector as shown in figure 8.
Ground
Receive pin on connected unit
Transmit pin on connected unit
Connected RS-232 and
Contact Closure Device Pins
Tx/Rx
Pins
Pin 1 f
or contact closure control
Pin 2 f
or contact closure control
RxTx
RS-232 Contact
21
G
REMOTE
Figure 8. RS-232 and Contact Closure Connector Wiring
Over DTP RS-232 Connector
Wire the rear Over DTP RS-232 connector as shown in figure 9.
Tx Rx G
OVER DTP
Ground
Receive pin on connected unit
Tr
ansmit pin on connected unit
Figure 9. Over DTP Connector Wiring
Extron DTP T UWP 4K D Series • Installation and Operation 11
Operation
AUTO SW
CONFIG
IR OUT
HDMI IN
AUDIO IN
S
G
HDCP
1
2
HDMI IN
AUDIO IN
E
AUTO SW
CONFIG
HDMI IN
AUDIO IN
HDCP
1
AUDIO IN
VGA IN
E
DTP T HWP 232/332 D
Front Panel
DTP T UWP 4K D
Front Panel
A
B
C
A
B
C
Figure 10. Transmitter LED Indicators
Transmitter LEDs
A Power LEDs — Two-color front panel LEDs on the transmitters light to indicate signal
and power status as follows:
Amber — The unit is receiving power but there is no signal on the associated input.
Green — The unit is receiving power and a signal is present on the associated
input.
NOTE: Both inputs on the transmitters have their own separate LEDs.
B Auto Switch LED — Lights steadily when auto switch is active (see item
C
on page
7).
C HDCP LEDs — Lights steadily when HDMI input has been authenticated on the source
device.
Extron DTP T UWP 4K D Series • Installation and Operation 12
System Operation
After the transmitter, the receiver, and their connected devices are powered up, the system
is fully operational. If any problems are encountered, ensure all cables are routed and
connected properly.
NOTES:
Ensure that the video source and display are properly connected to the transmitter
and receiver pair, and that the transmitter, the receiver, and the display have power
applied before power is applied to the video source. If all other devices are not
turned on before the video source, the image may not appear.
Input switching can be performed only via auto switching, RS-232, USB, or
contact closure through the rear panel connectors.
Audio Configuration
The DTP T UWP 4K D series can embed analog audio inputs onto the digital video output.
Use Extron PCS software (available at www.extron.com) or SIS commands to select the
desired embedded audio mode.
NOTE: If no VGA or HDMI signal is present, analog audio will be transported over
the DTP connection to the analog audio output of the receiver.
When an input is selected, audio transport over HDMI can be configured to operate in one
of three modes. Each input can be configured individually for any of the three modes.
Transport embedded digital audio (default) — The embedded digital audio
content on the digital video input is transported. Analog audio is still separate from the
embedded digital audio on the HDMI signal and transported simultaneously over the
DTP output, not embedded onto the digital output.
Embed analog audio input — The analog audio input is always embedded to the
digital output, replacing whatever content is already present on the embedded digital
audio. Analog audio is also transported over the DTP output as a simultaneous output.
Auto select between analog audio and digital audio — When both analog audio
and embedded digital audio on HDMI are present, embedded digital audio on the HDMI
signal takes priority. Analog audio is transported simultaneously with the embedded
digital audio content that is already present on the DTP output.
EDID Minder
EDID Minder ensures that source devices connected to the DTP T UWP 4K D inputs
continually recognize the EDID of a sink device, even if a sink is not physically connected.
By default, the EDID on the VGA input is configured for 1920x1080 @ 60 Hz, and the EDID
on the HDMI input is configured for 1080p @ 60 Hz with 2-channel audio.
EDID can be configured further using PCS software (see EDID Minder on page 23).
Extron DTP T UWP 4K D Series • Remote Control 13
Remote Control
This section includes:
Contact Closure Control
Simple Instruction Set Control
The DTP T UWP 4K D series of transmitters can be remotely controlled via their front panel
configuration (USB) port, rear panel Remote RS-232 port, and rear panel Remote Contact
port.
Contact Closure Control
The rear panel Remote port provides a way to select an input to the extender using a
remote contact closure device. For contact closure pin assignments, see “Contact” in item
C
, page 7.
To select a different input number using a contact closure device, momentarily short the pin
for the desired input number to ground. To force one of the inputs to be always selected,
leave the short to ground in place.
Simple Instruction Set Control
The DTP T UWP 4K D series of extenders can be remotely controlled using SIS commands
from a host device such as a computer or control system via its rear panel Remote RS-232
port (see item
C
on page 7) or front panel Configuration (USB) port (see item
D
on
page 6).
The default serial port protocol of the RS-232 port is as follows:
9600 baud No parity 8 data bits
No flow control1 stop bit
Host-to-Extender Communications
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command character sequence. When a command is valid, the
extender executes the command and sends a response to the host device. All responses
from the extender to the host end with a carriage return and a line feed (CR/LF =
]
), which
signals the end of the response character string. A string is one or more characters.
Extender-Initiated Messages
When a local event occurs, such as a front panel operation, loss or restoration of an input
signal, or an error condition, the extender responds by sending a message to the host.
Examples of the extender-initiated messages are listed below:
© Copyright 20yy, Extron Electronics DTP T UWP 4K 232 D, Vx.xx, 60-nnnn-nn
]
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

Extron DTP T UWP 4K 232 D Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues