Delta T17453-SS Mode d'emploi

Catégorie
Articles sanitaires
Taper
Mode d'emploi
107529 Rev. D
MultiChoice
®
Valve Trim
Installation Instructions
Owners Manual
17 Series
THIS VALVE MEETS OR EXCEEDS THE
FOLLOWING STANDARDS: ASME A112.18.1/
CSA B125.1 and ASSE 1016 (Type -P- or -T-).
CAUTION: This system/device must be set by the
installer to ensure safe, maximum temperature.
Any change in the setting may raise the discharge
temperature above the limit considered safe and
may lead to hot water burns.
NOTICE TO INSTALLER: CAUTION!–As the
installer of this valve, it is your responsibility
to properly INSTALL and ADJUST this valve
per the instructions given. This valve does
not automatically adjust for inlet temperature
changes, therefore, someone must make the
necessary Rotational Limit Stop adjustments
at the time of installation and further adjustments
may be necessary due to seasonal water
temperature change. YOU MUST inform the
owner/user of this requirement by following
the instructions. If you or the owner/user are
unsure how to properly make these adjustments
please refer to page 7 and if still uncertain, call
us at 1-800-345-DELTA.
After installation and adjustment, you must ax
your name, company name and the date you
adjusted the Rotational Limit Stop to the caution
label provided and apply or attach the label to
the back side of the closest cabinet door and the
warning label to the water heater. Leave this
Instruction Sheet for the owners/users
reference.
WARNING: This pressure balanced or
thermostatic bath valve is designed
to minimize the eects of outlet water
temperature changes due to inlet pressure
changes, commonly caused by dishwashers,
washing machines, toilets and the like. It may
not provide protection from hot water burns
when there is a failure of other temperature
controlling devices elsewhere in the
plumbing system, if the rotational limit stop
is not properly set or if the hot water
temperature is changed after the settings are
made or if the water inlet changes
due to seasonal changes.
WARNING: Do not install a shut-o device on
either outlet of this valve. When this type of
device shuts o the water ow, it can defeat
the ability of the valve to balance the hot and
cold water pressures.
10/20/2020 1
107529
Table of Contents:
Warranties ...............................................................................  Page 2
Installation Instructions ...........................................................  Pages   3 - 11
Clean and care.........................................................................  Page 12
Maintenance ............................................................................ Page 12
Cartridge Summary Reference Sheet .....................................   Page 12
For additional replacement parts, visit www.deltafaucet.com
You May Need
T
E
F
L
O
N
17 Series17 Series17 Series
X00107529
Write purchased model number here.
107529 Rev. D
2
Delta HDF Limited Warranty
All parts of the Delta HDF faucet are warranted to the
original consumer purchaser to be free from defects in
material and workmanship for a period of ve (5) years.
This warranty is made to the original consumer purchaser
and shall be eective from date of purchase as shown on
purchaser’s receipt.
Delta will replace, FREE OF CHARGE, during the warranty
period, any part which proves defective in material and/or
workmanship under normal installation, use and service.
Replacement parts can be obtained from your local
dealer or distributor listed in the telephone directory or by
returning the part along with the purchaser’s receipt to our
factory, TRANSPORTATION CHARGES PREPAID, at the
address listed. THIS WARRANTY IS THE ONLY EXPRESS
WARRANTY MADE BY DELTA. ANY CLAIMS MADE
UNDER THIS WARRANTY MUST BE MADE DURING
THE FIVE YEAR PERIOD REFERRED TO ABOVE. ANY
IMPLIED WARRANTIES, INCLUDING THE IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO
THE DURATION OF THIS WARRANTY. LABOR CHARGES
AND/OR DAMAGE INCURRED IN INSTALLATION, REPAIR
OR REPLACEMENT AS WELL AS INCIDENTAL AND
CONSEQUENTIALDAMAGES CONNECTED THEREWITH
ARE EXCLUDED AND WILL NOT BE PAID BY DELTA.
Some states do not allow limitations on how long an implied
warranty lasts, or the exclusion or limitation of incidental
or consequential damages, so the above limitations or
exclusions may not apply to you.
This warranty gives you specic legal rights, and you may
also have other rights which vary from state to state.
This warranty is void for any damage to this faucet due to
misuse, abuse, neglect, accident, improper installation, any
use violative of instructions furnished by us or any use of
replacement parts other than genuine Delta parts.
© 2020 Delta Faucet Company
Parts and Finish. All parts (other than electronic parts and batteries) and finishes of Delta® faucets purchased from authorized Delta sellers are warranted to the original
consumer purchaser to be free from defects in material and workmanship for as long as the original consumer purchaser owns the home in which the faucet was first
installed. For commercial purchasers, (a) the warranty period is ten (10) years for multi-family residential applications and (b) five (5) years for all other commercial
applications, in each case from the date of original purchase. For purposes of this warranty, the term “multi-family residential application” refers to the purchase of the
faucet from an authorized Delta seller by a purchaser who owns but does not live in the residential dwelling in which the faucet is initially installed, such as in a rented or
leased single unit or multi-unit detached home (duplex or townhome), or a condominium, apartment building or community living center. The following installations are not
considered multi-family residential applications, are excluded from the 10-year warranty and are subject to the 5-year warranty: industrial, institutional or other business
premises, such as a dormitory, hospitality premises (hotel, motel or extended stay location), airport, educational facility, long- or short-term healthcare facility (hospital,
rehabilitation center, nursing, assisted or staged-care living unit), public space or common area.
Parts and Finish for Delta® Recertified Faucets. Delta Faucet Company offers for sale on deltafaucet.com Delta® Recertified faucets. All parts (other than electronic
parts and batteries) and finishes of these Delta® Recertified faucets are warranted to the original consumer purchaser to be free from defects in material and workmanship
for ten (10) years from the date of original purchase. For commercial purchasers, the warranty period is one (1) year from the date of original purchase.
Electronic Parts. Electronic parts (other than batteries), if any, of Delta® faucets purchased from deltafaucet.com or authorized Delta sellers are warranted to the original
consumer purchaser to be free from defects in material and workmanship for five (5) years from the date of original purchase or, for commercial purchasers, for one (1)
year from the date of original purchase. No warranty is provided on batteries.
What We Will Do. Delta Faucet Company will repair or replace, free of charge, during the applicable warranty period (as described above), any part or finish that proves
defective in material and/or workmanship under normal installation, use and service. If repair or replacement is not practical, Delta Faucet Company may elect to refund
the purchase price in exchange for the return of the product. These are your exclusive remedies.
What Is Not Covered. Because Delta Faucet Company is unable to control the quality of Delta products sold by unauthorized sellers, unless otherwise prohibited by law,
this warranty does not cover Delta products purchased from unauthorized sellers.
Any labor charges incurred by the purchaser to repair, replace, install or remove this product are not covered by this warranty. Delta Faucet Company shall not be liable
for any damage to the faucet resulting from reasonable wear and tear, outdoor use, misuse (including use of the product for an unintended application), freezing water,
abuse, neglect or improper or incorrectly performed installation, maintenance or repair, including failure to follow the applicable care and cleaning instructions. Delta Faucet
Company recommends using a professional plumber for all installation and repair of faucets. We also recommend that you use only genuine Delta® replacement parts.
What You Must Do To Obtain Warranty Service or Replacement Parts. A warranty claim may be made and replacement parts may be obtained by calling 1 800 345
DELTA (3358) or by contacting us by mail or online as follows (please include your model number and date of original purchase):
In the United States and Mexico: In Canada:
Delta Faucet Company Masco Canada Limited, Plumbing Group
Product Service Technical Service Centre
55 E. 111th Street 350 South Edgeware Road
Indianapolis, IN 46280 St. Thomas, Ontario, Canada N5P 4L1
Attention: Warranty Service Attention: Warranty Service
www.deltafaucet.com/service-parts/contact-us http://www.deltafaucet.ca/customersupport/assistance.html
Proof of purchase (original sales receipt) from the original purchaser must be made available to Delta Faucet Company for all warranty claims unless the purchaser has
registered the product with Delta Faucet Company or the product is a Delta® Recertified product purchased from deltafaucet.com. This warranty applies only to Delta®
faucets manufactured after January 1, 2019 and installed in the United States of America, Canada and Mexico.
Limitation on Duration of Implied Warranties. Please note that some states/provinces (including Quebec) do not allow limitations on how long an implied warranty
lasts, so the below limitations may not apply to you. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, ANY IMPLIED WARRANTY, INCLUDING THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE, IS LIMITED TO THE STATUTORY PERIOD OR THE DURATION
OF THIS WARRANTY, WHICHEVER IS SHORTER.
Limitation of Special, Incidental or Consequential Damages. Please note that some states/provinces (including Quebec) do not allow the exclusion or limitation of
special, incidental or consequential damages, so the below limitations and exclusions may not apply to you. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE
LAW, THIS WARRANTY DOES NOT COVER, AND DELTA FAUCET COMPANY SHALL NOT BE LIABLE FOR, ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL
DAMAGES (INCLUDING LABOR CHARGES TO REPAIR, REPLACE, INSTALL OR REMOVE THIS PRODUCT), WHETHER ARISING OUT OF BREACH OF ANY
EXPRESS OR IMPLIED WARRANTY, BREACH OF CONTRACT, TORT, OR OTHERWISE. DELTA FAUCET COMPANY SHALL NOT BE LIABLE FOR ANY DAMAGE
TO THE FAUCET RESULTING FROM REASONABLE WEAR AND TEAR, OUTDOOR USE, MISUSE (INCLUDING USE OF THE PRODUCT FOR AN UNINTENDED
APPLICATION), FREEZING WATER, ABUSE, NEGLECT OR IMPROPER OR INCORRECTLY PERFORMED INSTALLATION, MAINTENANCE OR REPAIR,
INCLUDING FAILURE TO FOLLOW THE APPLICABLE INSTALLATION, CARE AND CLEANING INSTRUCTIONS. Notice to residents of the State of New Jersey: The
provisions of this warranty, including its limitations, are intended to apply to the fullest extent permitted by the laws of the State of New Jersey.
Additional Rights. This warranty gives you specific legal rights, and you may also have other rights which vary from state/province to state/province.
This is Delta Faucet Company’s exclusive written warranty and the warranty is not transferable.
If you have any questions or concerns regarding our warranty, please contact us as provided above or view our Warranty FAQs at www.deltafaucet.com.
Limited Warranty on Delta
®
Faucets
© 2020 Delta Faucet Company
107529 Rev. D
SHUT OFF WATER SUPPLIES.
Consider the type and thickness of your
finished wall before placing your stringer
back plate. Install the body (1) so the
surface of the finished wall is flush with the
front of the plasterguard (2) ± 3/8". Note:
For models with stops (3), plasterguard
A.
B.
Distance (1) from the stringer (2) to the
front of the plasterguard is 2.8" (71 mm).
must be flush or subflush 3/8" to
finished wall. Mount body using the two
stringer mounting holes (4) on the bracket.
Make sure the word “UP” (5) is on top of the
valve body when installing.
If a thin wall is used, be sure to have the
plasterguard behind the wall, otherwise the
wall should always be flush with the front of
the plasterguard. See instruction on the bag
for thin wall mounting.
1
2
5
4
4
1
2
3
3
1
MultiChoice
®
Rough-In Installation
(When your product requires)
107529 Rev. D
Connect valve body to water supplies using
the proper fittings for your valve body type
(copper tubing, iron pipe or Pex). Note: (1) is
the cold inlet port and (2) is the hot inlet
port. If either of the two outlet ports is to be
unused, seal the port with a pipe plug.
Remove bonnet (1). Warning: Avoid
soldering at high temperatures.
Be sure stops (2) are removed from the
w/stops version before soldering. (Do not
install stops before soldering.)
If you are making a back to back or
reverse installation (hot on right and
cold on left) install the valve body as
described, but the water supply lines will
be reversed. Note: (1) is the hot inlet
port and (2) is the cold inlet port.
Copper Tubing Iron Pipe
Pex
C.
1
2
1
2
1
2
D.
1
2
4
107529 Rev. D
Connect top outlet (1) to shower pipe
with proper ttings. Connect bottom outlet
(2) to tub spout pipe with proper ttings.
Pipe (3) between valve body and tub
spout must be a minimum of 1/2" (13 mm)
copper pipe or 1/2" (13 mm) iron pipe in a
straight drop no less than 8" (203 mm) but
no more than 18" (457 mm) long with only
one iron pipe or copper 90 degree elbow
to the tub spout nipple. Do not use PEX
tubing for tub spout drop.
E.
1
2
3
5
107529 Rev. D
2
Cartridge Installation
Turn o water supplies. Remove bonnet
nut (1) and test cap (2) from the body. If
this is not a thin wall mounting, the entire
plasterguard (3) may be removed. If screen
(4) is in place, remove before installing
cartridge.
Insert adapter assembly (1) into valve
body. Make sure the adapter assembly
is correctly positioned and is pressed all
the way down inside body. Remove the
retainer (2) from the adapter.
Rotate cartridge (1) so the words
“HOT SIDE” (2) appear on the left. Insert
cartridge assembly into valve body.
Make sure the key (3) on the cartridge is
fully engaged with the slot in the brass
body (4). Slide bonnet nut (5) over the
cartridge and thread onto the body.
Hand tighten securely.
For back to back or reverse installations
(hot on right and cold on left): Rotate
cartridge (1) so the words “HOT SIDE” (2)
appear on the right. Install the cartridge
making sure that the key is fully engaged
with the slot in the brass body (See step C).
Slide bonnet nut (3) over the cartridge and
thread onto the body. Hand tighten securely.
6
A.
1
2
4
3
B.
1
2
C.
1
3
4
5
2
Back to back Installation
Normal Installation
(changes not required)
Reverse
Installation
Cold
Hot
1
3
2
107529 Rev. D
3
7
Shower Head and Tub Spout Installation
A.
1
2
3
4
FOR SHOWER HEAD INSTALLATION: Connect top
outlet (1) to shower arm (2) with proper ttings. To
prevent damage to nish on shower arm, insert wall end
of shower arm into shower ange (3) before screwing
arm into riser connection. Thread shower head (4) onto
shower arm. Apply plumber tape to pipe threads on both
ends. Do not overtighten shower head.
To combine the two showers, connect the top slot (1) of the handshower onto the tab (2) of the
showerhead. Push the handshower into the showerhead until the two parts snap together.
If the showerhead moves when removing the handshower, hand tighten the connection between
the showerhead and the shower arm.
To change spray modes, turn the lever/dial (3) left or right, or push button (3), to the desired setting. Turn
knob or lever (4) to change between showerhead only, showerhead and handshower or handshower only.
B.
1
2
4
3
107529 Rev. D
FOR TUB SPOUT INSTALLATION:
Refer to the installation instructions supplied with your spout. Do not connect deck mount spouts to
in-wall valves. Do not use hand showers connected in lieu of a tub spout to a tub/shower valve. Do not
use PEX tubing for tub spout drop.
8
107529 Rev. D
4
9
Trim Installation
Slide O-ring (1) over cartridge and the
bonnet nut (2). The O-ring, which acts as
a spacer to steady the sleeve, should rest
behind the bonnet nut. Slide the sleeve
(3) over the cartridge, body and O-ring.
Ensure sleeve is properly positioned over
the front of cartridge.
Install volume control handle (1) with lever
to the right. Seat stop (2) into volume
handle. Turn to the on position.
DO NOT SECURE WITH SCREW.
Note: Adust for up to 1" thick wall. For thick
wall installation, visit delta faucet website,
check "view technical specication" of the
models you bought, order the appropriate
thick wall installation kit RP to get
additional 1 3/4" wall thickness.
B-1: Secure the escutcheon (1) and backplate
(2) (if your model has one) to the bracket
(3) using the 2 screws (4) provided. Do not
overtighten escutcheon screws. Press the
cover (5) onto the escutcheon (1) when your
product includes the cover.
B-2: Install bracket (5) over the cartridge
body using the 2 screws (6) provided. Install
escutcheon (7) by placing it over the bracket
as shown and rotating it to lock the tabs (8).
Secure the escutcheon to the bracket using set
screw (9).
8
9
7
6
5
8
B-1
B-2
4
1
2
3
5
A.
1
2
3
C.
1
2
107529 Rev. D
5
Installation and Adjustment of the Rotational Limit Stop
Place the temperature control knob (1) on
volume handle and rotate to the mixed
position
(if required). DO NOT SECURE WITH
SCREW. Turn on water supplies; let the
water
run until both hot and cold water is as hot/
cold
as possible. Place thermometer in a plastic
tumbler, and hold the tumbler in the water
stream. Record the temperature reading.
Secure temperature control knob (1) with
screw (2). Hook (3) front of temperature
control cover (4) onto knob (1) before
engaging rear snap (5).
If the water temperature is above 120°F,
remove the temperature control knob (1)
and rotate the limit stop (2) clockwise one
tooth for every 4°F - 6°F (approximate)
change in temperature. If water temperature
is cooler than desired, rotate the limit stop
counterclockwise.
IMPORTANT: The rst position of the
Rotational Limit Stop (the Limiter) is that
position that restricts the rotation of the
stem the most and is at the maximum
clockwise setting. According to industry
standards, the maximum allowable
temperature of the water exiting from the
valve is 120
o
F. This temperature may vary
in your local area. The Rotational Limit Stop
may need to be readjusted if the inlet water
temperature changes. For instance, during
the winter, the cold water temperature is
colder than it is during the summer which
could result in varying outlet temperatures.
Typical temperature for a comfortable bath
or shower is between 90
o
–110
o
F.
10
Secure temperature control knob (1) with
screw (2). snap on temperature control cover
(3) with side snaps onto knob (1).
C-2
3
1
5
2
4
C-1
1
2
3
B.
Hotter
Colder
1
2
A.
1
107529 Rev. D
11
6
Potential scald or thermal shock injury could result due to cross ow if outlet at the
shower is blocked or restricted (e.g., pause control on hand shower). Be sure to point
hand shower away from you when re-starting ow or install inlet check valves on both
supply lines to prevent possible injury.
Place volume handle (11) onto cartridge.
Seat stop (13) into volume handle, place
adapter (14) into handle and tighten screw
(15). Thread cover (12) onto handle. Place
temperature handle assembly (16) onto
cartridge and drive set screw (17).
C-3
C-4
11
13
14
15
16
17
12
Install adapter (1) over valve stem (2) and secure it with screw (3).
Install washer (4) onto handle (5), slide handle onto adapter and secure it with screw (6), then
cover set screw with handle button (7).
1
3
4
5
7
6
2
107529 Rev. D
Clean and Care
Care should be given to the cleaning
of this product. Although its nish is
extremely durable, it can be damaged by
harsh abrasives or polish. To clean, simply
wipe gently with a damp cloth and blot dry
with a soft towel.
Warning: Scrubbing Bubbles
®
Bathroom
Cleaner and Lysol
®
Basin Tub and Tile
Cleaner must not be used on the clear knob
handles and levers. Use of these cleaners
can result in cracked or severely damaged
handles. If overspray gets onto the handles,
immediately wipe them dry with a soft
cotton cloth.
Maintenance
Faucet leaks from tub spout/hand shower:
SHUT OFF WATER SUPPLIES.
Replace valve cartridge
RP46463 or RP32104
See Helpful Hints 1, 2 & 3.
Helpful Hints:
1. Before removing valve cartridge assembly for any
maintenance, be sure to note the position of the
rotational limit stop on the cap. The valve cartridge
assembly must always be put back in the same
position. BE SAFE! After you have nished the
installation, turn on valve to make sure COLD
WATER FLOWS FIRST.
2. To remove valve cartridge from body, shut o
water supplies and remove handle and bonnet nut.
Do not pry the valve cartridge out of the body with
a screwdriver. Place handle on stem and rotate
counterclockwise approximately 1/4 turn after the
stop has been contacted. Lift valve cartridge out
of body.
Remove seats and springs and replace.
Place the largest diameter of the spring into the
seat pocket rst and then press the tapered end
of the seal over the spring. Reassemble valve
cartridge and replace in body following instructions
given in 1 above.
3. If the water in your area has lime, rust, sand
or other contaminants in it, your pressure
balance valve will require periodic inspection.
The frequency of the inspection will depend
on the amount of contaminants in the water. To
inspect valve cartridge remove it and follow the
steps in note 1 above. Turn the valve to the full
mix position and shake the cartridge vigorously.
If there is a rattling sound, the unit is functional
and can be reinstalled following instructions given
in note 1 above. If there is no rattle, replace the
housing assembly with the proper RP.
12
Cartridge Summary Reference Sheet
Units shipped in March
2006 and after.
Units shipped before
March 2006.
Order RP46463 to
Replace Cartridge.
Order RP32104 to
Replace Cartridge.
Grey Upper Cap
White Upper Cap
V Notch
Square Notch
Adapter
Shorter Tab Longer Tab
17 1700
107529 Rev. D
1
Instrucciones para la
Instalación del Accesorio
para Válvulas MultiChoice
®
Manual para los
Propietarios
17 Series
Escriba aquí el número del modelo comprado.
Usted puede necesitar
Para las piezas de repuesto adicionales, visite www.deltafaucet.com
Contenido:
Garantías ................................................................................. Page 2
Instrucciones de Instalación .................................................... Pages 3 - 11
Limpieza y Cuidado de su Liave .............................................. Page 12
Mantenimiento .......................................................................... Page 12
Hoja resumen de referencia para el cartucho ...........................Page 12
compañía y la fecha cuando ajustó el Tope del
Límite Rotacional y aplicar o jar la etiqueta al
dorso de la puerta del gabinete más cercano
y la etiqueta de aviso al calentador de agua.
Deje la Hoja de Instrucciones para referencia
del dueño/usuario.
ADVERTENCIA: Esta válvula de presión
balanceada y termostática está diseñada
para minimizar los efectos de los cambios
de temperatura de agua por causa de los
cambios de presión en el agua de entrada,
comúnmente causados por lavadoras de
platos, lavadoras de ropa, inodoros, y otros
aparatos por el estilo. Puede no proporcionar
protección de quemaduras de agua caliente
cuando hay alguna falla de otros aparatos
para el control de temperatura en otro
sitio en el sistema de plomería. También
no proporcionará protección si el tope del
límite rotacional la temperatura no está
apropiadamente jo o si cambia la
temperatura del agua caliente después de
hacer los ajustes o si los cambios del gua
de entrada son por los cambios estacionales.
ADVERTENCIA: No instale un aparato de corte
o cierre en cualquiera de las tomas de esta
válvula. Cuando este tipo de aparato cierra el
ujo de agua, puede hacer fallar la habilidad
de la válvula de balancear las presiones del
agua caliente y fría.
ESTA VÁLVULA CUMPLE O EXCEDE LAS
SIGUIENTES NORMAS: ASME A112.18 1 / CSA
B125.1 y ASSE 1016 (Type -P- or -T-).
ADVERTENCIA: El instalador debe apostar
este systema/divisa para garantizar temperatura
maximo y seguro. Cualqueir cambio en el ajuste
puede subir la temperatura del agua de descarga
sobre el límite considerado seguro y puede
resultar en quemaduras de agua caliente.
AVISO PARA EL INSTALADOR: PRECAUCIÓN
– Como instalador de esta válvula, es su
responsabilidad de INSTALAR Y AJUSTAR
apropiadamente esta válvula como se describe
en las instrucciones, por lo tanto, debe haber
una persona para hacer los ajustes necesarios
del Tope del Límite Rotacional y del pomo
para la temperatura en el momento que se
haga la instalación y pueda necesitar ajustes
adicionales por los cambios estacionales
de la temperatura del agua. USTED DEBE
informarle al dueño/usuario sobre este
requisito siguiendo las instrucciones. Si usted
o el dueño/usuario no están seguros como
hacer estos ajustes apropiadamente, por favor
reérase al Página 7 y si todavía no está seguro,
llámenos al 1-800-345-DELTA.
Después de hacer la instalación y el ajuste, usted
puede agregarle a la etiqueta de aviso
proporcionada, su nombre, el nombre de
lacompañía y la fecha cuando ajustó el Tope del
10/20/2020
T
E
F
L
O
N
107529
107529 Rev. D
2
Garantia Limitada de Delta HDF
Todas las piezas de la llave Delta HDF están
garantizadas al dueño original de estar libres de
defectos en materiales y en la mano de obra por un
período de cinco (5) años. Esta garantía se hace al
dueño original y será efectiva el día de la compra como
se ve en el recibo de compra.
Delta reemplazará, LIBRE DE CARGO, durante el
período de la garantía, cualquier pieza que resulte
defectuosa en materiales y/o en la mano de obra bajo
instalación, uso y servicio normal. Las piezas de
repuesto pueden ser obtenidas de su comerciante o
distribuidor local que se encuentran en la guía telefónica
o si usted devuelve la pieza con el recibo de compra
a nuestra fabrica, Y LOS CARGOS DE TRANSPORTE
PAGADOS CON ANTELACION, a la dirección dada.
ESTA GARANTIA ES LA UNICA GARANTIA EXPRESA
DE DELTA. CUALQUIER RECLAMO HECHO BAJO
ESTA GARANTIA TIENE QUE SER HECHO DURANTE
EL PERIODO DE CINCO AÑOS A QUE SE REFIERE
ARRIBA. CUALQUIER GARANTIA IMPLICITA,
INCLUYENDO LA GARANTIA IMPLICITA DE
COMERCIALIZACION O CONVENIENCIA PARA UN
PROPOSITO PARTICULAR, SON LIMITADOS EN
DURACION A LA DURACION DE ESTA GARANTIA.
LOS CARGOS PARA LA MANO DE OBRA Y/O DAÑOS
INCURRIDOS EN LA INSTALACION, REPARACION O
REEMPLAZO, ASI COMO LOS DAÑOS INCIDENTALES
O CONSECUENTES CONECTADOS CON
ELLOS SON EXCLUIDOS Y NO SERAN PAGADOS
POR DELTA.
Algunos estados no permiten limitaciones al tiempo que
dura la garantía implícita, o la exclusión o limitación de
los daños incidentales o consecuentes, así que la
limitación o exclusión expresada arriba puede no ser
aplicable a usted.
Esta garantía le da a usted derechos legales especícos
y usted puede también tener otros derechos que varían
de estado a estado.
Esta garantía es nula por cualquier daño a esta llave
que sea el resultado del mal uso, abuso, negligencia,
accidente, instalación impropia, cualquier uso en
violación de las instrucciones suministradas por
nosotros o cualquier uso de piezas de repuesto que no
sean piezas genuinas Delta.
© 2020 Delta Faucet Company
Piezas y Acabado. Todas las piezas (excepto los componentes electrónicos y las pilas) y los acabados de los grifos Delta Faucet® comprados de vendedores autor-
izados por Delta están garantizados al consumidor comprador original de estar libres de defectos en material y fabricación durante el tiempo que el comprador original
sea propietario de la vivienda en la que el grifo/la llave de agua fue originalmente instalada. En el caso de los consumidores comerciales, (a) el período de garantía
es de diez (10) años para aplicaciones multifamiliares (apartamentos y condominios) y (b) cinco (5) años para todos las otras aplicaciones comerciales, en cada caso
a partir de la fecha de compra. Para los propósitos de esta garantía, el término “aplicación multifamiliar residencial” se refiere a la compra del grifo de un vendedor
autorizado por Delta por el comprador propietario que no vive en la vivienda residencial donde se instaló inicialmente la llave de agua, como en una unidad alquilada
o arrendada, o unidad o vivienda unifamiliar separada (dúplex o casas adosadas), o un condominio, edificio de apartamentos o centro de vivienda comunitaria. Las
siguientes instalaciones no se consideran aplicaciones multifamiliares residenciales, están excluidas de la garantía de 10 años y están sujetas a la garantía de cinco
años: instalaciones industriales, institucionales u otras instalaciones comerciales, como dormitorios, instalaciones de hotelería (hotel, motel o una alberga para estadías
prolongadas), aeropuerto, centro educativo, centro de atención de salud a corto o largo plazo (hospital, centro de rehabilitación, asilo de ancianos, unidad de vivienda
asistida o una unidad residencial de cuidado), espacio público o área común.
Piezas y acabados para grifos recertificados Delta®. Delta Faucet Company ofrece para la venta en deltafaucet.com llaves de agua/grifos recertificados Delta®. Todas
las piezas electrónicas (excepto las partes electrónicas y las pilas) y los acabados de estos grifos recertificados Delta® están garantizados al consumidor comprador
original de estar libres de defectos en material y fabricación durante diez (10) años a partir de la fecha de compra. Para los consumidores comerciales, el período de
garantía es por un (1) año a partir de la fecha de compra.
Piezas electrónicas. Las piezas electrónicas (excepto las pilas), si las hay, de las llaves de agua Delta® compradas de deltafaucet.com o vendedores autorizados por
Delta están garantizadas al consumidor comprador original de estar libres de defectos en material y fabricación durante cinco (5) años a partir de la fecha de compra o
para los consumidores comerciales, por un (1) año a partir de la fecha de compra. No se garantizan las pilas.
Lo que haremos. La compañía Delta Faucet Company reparará o reemplazará, sin costo alguno, durante el período de garantía aplicable (como descrito arriba)
cualquier pieza o acabado que demuestre ser defectuosa en material y/o fabricación bajo la instalación, el uso y el servicio normal. Si la reparación o el reemplazo no
es práctico, Delta Faucet Company puede optar por reembolsarle el precio de compra a cambio de la devolución del producto. Estos son sus remedios exclusivos.
Lo que no cubre. Debido a que Delta Faucet Company no puede controlar la calidad de los productos Delta vendidos por vendedores no autorizados, a menos que la
ley lo prohíba, esta garantía no cubre los productos Delta comprados a vendedores no autorizados.
No cubre cualquier gasto de labor incurrido por el comprador para reparar, reemplazar, instalar o desmontar este producto. Delta Faucet Company no es responsable por
cualquier daño al grifo que resulte del desgaste razonable, uso en el exterior, uso indebido, (incluyendo el uso del producto para una aplicación indebida), agua helada,
abuso, negligencia o la instalación, el mantenimiento o la reparación incorrecta, incluido el incumplimiento de las instrucciones de cuidado y limpieza correspondientes.
Delta Faucet Company recomienda el uso de los servicios de un plomero profesional para toda instalación y reparación de los grifos. También recomendamos que use
solo piezas de repuesto genuinas Delta®.
Lo que usted debe hacer para obtener servicio de garantía o piezas de repuesto. Se puede hacer un reclamo de la garantía y se pueden obtener piezas de repuesto
llamando al 1-877-345-DELTA (3358) o contactándonos por correo postal o electrónico como indicado (favor incluya el número del modelo y la fecha de compra):
En los Estados Unidos y México: En Canadá:
Delta Faucet Company Masco Canada Limited, Plumbing Group
Product Service Technical Service Centre
55 E. 111th Street 350 South Edgeware Road
Indianapolis, IN 46280 St. Thomas, Ontario, Canada N5P 4L1
Attention: Warranty Service Attention: Warranty Service
www.deltafaucet.com/service-parts/contact-us http://www.deltafaucet.ca/customersupport/assistance.html
El comprobante de compra (recibo de venta original) del comprador original debe ser disponible a Delta Faucet Company para todos los reclamos de garantía a menos
que el comprador haya registrado el producto en Delta Faucet Company o es un producto recertificado de Delta® comprado de deltafaucet.com. Esta garantía aplica
solo a las llaves de agua/grifos Delta® fabricados después de enero 1, 2019 e instalados en los Estados Unidos de América, Canadá y México.
La limitación de la duración de las garantías implícitas. Favor tomar nota que algunos estados/provincias (incluyendo Quebec) no permiten las limitaciones de
la duración de una garantía implícita por lo que las limitaciones a continuación puedan no aplicarle. HASTA EL ALCANCE MÁXIMO EN QUE LA LEY LO PERMITA,
CUALQUIER GARANTA IMPLCITA, INCLUIDAS LAS GARANTAS IMPLCITAS DE COMERCIABILIDAD Y DE IDONEIDAD PARA UN PROPSITO PARTICULAR,
ESTÁ LIMITADA AL PERODO LEGAL O A LA DURACIN DE ESTA GARANTA, LO QUE SEA MÁS CORTO.
Limitación de daños especiales, incidentales o consiguientes. Favor de tomar nota que algunos estados/provincias (incluyendo Quebec) no permiten la exclusión
o limitación de daños especiales, incidentales o consecuentes, por lo que estas limitaciones y exclusiones puedan no aplicarle. HASTA EL ALCANCE EN QUE LA
LEY LO PERMITA, ESTA GARANTA NO CUBRE Y DELTA FAUCET COMPANY NO SE HACE RESPONSABLE, POR NINGN DAÑO ESPECIAL, INCIDENTAL
O CONSIGUIENTE (INCLUYENDO LOS GASTOS DE LABOR PARA REPARAR, REEMPLAZAR, INSTALAR O DESMONTAR ESTE PRODUCTO), YA SEA EL
RESULTADO DEL INCUMPLIMIENTO DE CUALQUIER GARANTA EXPRESA O IMPLCITA, INCUMPLIMIENTO DE CONTRATO, AGRAVIO O DE OTRA MANERA.
DELTA FAUCET COMPANY NO SE RESPONSABILIZARÁ POR CUALQUIER DAÑO AL GRIFO QUE RESULTE DEL DESGASTE RAZONABLE, USO EN EL EXTERIOR
DE LA PROPIEDAD, USO INDEBIDO (INCLUYENDO EL USO DEL PRODUCTO PARA UNA APLICACIN INDEBIDA), AGUA HELADA, ABUSO, NEGLIGENCIA O
INSTALACIN O MANTENIMIENTO INADECUADO O INCORRECTO, INCLUYENDO EL NO SEGUIR LAS INSTRUCCIONES CORRESPONDIENTES PARA EL
CUIDADO, LA LIMPIEZA Y EL MANTENIMIENTO. Aviso para los residentes del estado de New Jersey: Las disposiciones de este documento tienen la intención de
aplicarse en la máxima medida permitida por las leyes del estado de New Jersey.
Derechos adicionales. Esta garantía le otorga derechos legales específicos y también puede tener otros derechos que varían de estado/provincia a estado/provincia.
Esta es la garantía escrita exclusiva de Delta Faucet Company y la garantía no es transferible.
Si tiene preguntas o dudas con respecto a nuestra garantía, por favor comuníquese con nosotros como se indica anteriormente o consulte nuestras Preguntas Frecuentes
Warranty FAQs en www.deltafaucet.com.
Garantía Limitada en las Llaves de Agua de Delta
®
© 2020 Delta Faucet Company
107529 Rev. D
3
CIERRE LOS SUMINISTROS DE AGUA.
Considere el tipo y el grosor de su pared
terminada antes de colocar su placa trasera
de acoplamiento de las tuberías. Instale la
pieza (1) de manera que la superficie de la
pared terminada quede al ras con el frente
del protector de yeso (2) ± 3/8". Nota: Para
con los modelos de las paradas (3), el
protector del yeso debe ser el rubor
A.
B.
rasante o secundario el 3/8a la pared
acabada. Instale la pieza usando los dos
agujeros de instalación del acoplamiento (4)
en el soporte.
Cuando esté haciendo la instalación,
asegúrese que la palabra “UP” (5) quede
arriba de la válvula.
1
2
5
4
4
1
2
3
1
Instalación de la plomería MultiChoice
®
(Cuando su producto lo requiero)
La distancia (1) del larguerillo (2) a la
parte delantera del protector de yeso es
de 2.8” (71 mm).
Si se utiliza una pared delgada,
asegúrese de tener el protector de yeso
por detrás de la pared, de lo contrario,
la pared siempre debe estar al ras con
la parte delantera del protector de yeso.
Consulte las instrucciones en la bolsa
para el montaje en pared delgada.
107529 Rev. D
4
Conecte el cuerpo de la válvula a los sumin-
istros de agua usando los accesorios apro-
piados para el tipo de su válvula (tubería de
cobre, hierro o Pex). Nota: (1) es la entrada
del agua fría y el (2) es la entrada del agua
caliente. Si no va a usar alguna de las dos
entradas de agua, séllela con un tapón
de tubería.
Si está hacienda una instalación dorso
con dorso o a la inversa (caliente en la
derecha y fría en la izquierda) instale el
cuerpo de la válvula como se describe
arriba, pero coloque al inverso las líneas
de suministro de agua. Nota: (1) es
la entrada de agua caliente (2) es la
entrada del agua fría.
Tubería de
Cobre
Hierro
Pex
D.
Quite el capuchón (1). Advertencia: Evite
soldar a temperaturas altas.
Sea seguro que las válvulas apagadas
(2) están quitadas de la versión con las
paradas antes de soldar. (no instale las
válvulas apagadas antes de soldar.)
1
2
C.
1
2
1
2
1
2
107529 Rev. D
5
Conecte la salida de arriba (1) a la
tubería de la regadera con los accesorios
apropiados. Conecte la salida de abajo
(2) a la tubería del surtidor de la bañera
con los accesorios apropiados. La tubería
(3) entre el cuerpo de la válvula y el de la
bañera debe ser de un mínimo de 1/2" (13
mm) de tubería de cobre ó 1/2" (13 mm) de
tubería de hierro en caída recta no menos
de 8" (203 mm) pero no más de 18" (457
mm) de largo a la entrerrosca del surtidor
de la bañera y con sólo un codo de 90
grados, de tubería de hierro o cobre.
No
use la tubería PEX como tubería entre
la válvula y el surtidor de la bañera.
E.
1
2
3
107529 Rev. D
6
2
Instalación del Cartucho
Cierre los suministros de agua. Quite la
tuerca tapa (1) y la tapa de prueba (2). Si
no es para instalar en pared delgada, puede
quitar el protector (3) de yeso completo. Si
la pantalla (4) está en lugar, quite antes de
instalar el cartucho.
Introduzca el adaptador (1) en la válvula.
Asegúrese que el adaptador estén
correctamente colocados dentro de los
oricios en la base de la válvula. Quite el
retenedor (2) del adaptador.
Gire el cartucho (1) de manera que las
palabras ‘HOT SIDE’ (LADO CALIENTE) (2)
aparezcan en la izquierda. Introduzca el
cartucho en la válvula. Asegúrese que la
guía (3) en el cartucho esté totalmente
encajada en la muesca del cuerpo de
latón (4). Deslice la tuerca tapa (5) sobre
el cartucho y enrosque en el cuerpo de la
válvula. Apriete a mano bien.
En las instalaciones dorso con dorso (el agua
caliente en la derecha y la fría en la izquierda):
Gire el cartucho (1) de manera que las palabras
“HOT SIDE” (LADO CALIENTE) (2) aparezcan
en la derecha. Instale el cartucho asegurando
que la guía quede totalmente encajada en la
muesca de la pieza de latón. Deslice la tuerca
tapa (3) sobre el cartucho y enrosque en el
cuerpo de la válvula. Apriete a mano bien.
Instalación de Espalda a Espalda
Instalación Normal
(No serequerá cambios)
Instalación
Invertido
Fría
Caliente
A.
B.
1
2
4
3
1
2
1
2
3
C.
1
3
4
5
2
107529 Rev. D
Instalación de Espalda a Espalda
3
Instalación de la Cabeza de la Regadera y el Surtidor de la Bañera
PARA LAS INSTALACIONES DE LAS CABEZAS
DE REGADERA: Conecte la toma de salida de
agua superior (1) al brazo de la regadera (2) con los
accesorios apropiados. Para prevenir daño al acabado
del brazo de la regadera, introduzca el extremo que
va hacia la pared del brazo de la regadera dentro del
reborde (3) antes de atornillar el brazo en la conexión de
la tubería vertical. Aplique cinta para plomero a los enrosques
de la tubería. No apriete demasiado la cabeza de la
regadera.
7
A.
1
2
3
4
Para combinar las dos regaderas, conecte la ranura superior (1) de la ducha de mano en la lengüeta (2)
del cabezal de la regadera. Presione la ducha de mano en el cabezal de la regadera hasta que las dos
partes encajen.
Si la cabeza de la regadera se mueve cuando retira la regadera manual, apriete a mano la
conexión entre la cabeza de la regadera y el brazo de la regadera.
Para cambiar los modos de rocío, gire la palanca/dial (3) hacia la izquierda o hacia la derecha, o presione
el botón (3), a la conguración deseada. Gire la perilla o palanca (4) para cambiar entre los modos de
solo la regadera, la regadera y la ducha de mano o solo la ducha de mano.
B.
1
2
4
3
107529 Rev. D
PARA LA INSTALACIóN DEL SURTIDOR DE LA BAÑERA: Reérase a las instrucciones para la
instalación suministradas con su surtidor. No conecte los surtidores para las instalaciones en las
supercies horizontales en las válvulas dentro de las paredes. No use las regaderas de mano en vez
de un surtidor de bañera conectado a una válvula de bañera/regadera. No use la tubería PEX como
tubería entre la válvula y el surtidor de la bañera.
8
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Delta T17453-SS Mode d'emploi

Catégorie
Articles sanitaires
Taper
Mode d'emploi