Jenn-Air JXU9130HP Le manuel du propriétaire

Catégorie
Hottes
Taper
Le manuel du propriétaire

Ce manuel convient également à

JENNAIR
®
30" AND 36" (76.2 CM AND 91.4 CM)
COMMERCIAL STYLE WALL-MOUNT CANOPY
RANGE HOOD
HOTTE DE CUISINIÈRE JENNAIR
®
POUR MONTAGE
MURAL DE STYLE COMMERCIAL
30" ET 36" (76,2 CM ET 91,4 CM)
Installation Instructions and Use & Care Guide
For questions about features, operation/performance, parts, accessories, or service in the U.S.A., call:
1-800-JENNAIR (1-800-536-6247) or visit our website at www.jennair.com.
In Canada, call: 1-800-JENNAIR (1-800-536-6247), or visit our website at www.jennair.ca.
Instructions d’installation et Guide d’utilisation et d’entretien
Au Canada, pour assistance, installation ou service, composez le 1-800-JENNAIR (1-800-536-6247) ou visitez notre site web à
www.jennair.ca.
Table of Contents/Table des matières .....................................2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPOR
TANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT
.
LI3V3D/W11374533A
2
RANGE HOOD SAFETY
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
TABLE OF CONTENTS TABLE DES MATIÈRES
RANGE HOOD SAFETY .................................................................2
INSTALLATION REQUIREMENTS .................................................4
Tools and Parts .............................................................................4
Location Requirements ................................................................4
Venting Requirements ..................................................................5
Electrical Requirements ...............................................................6
INSTALLATION INSTRUCTIONS ...................................................7
Prepare Location ..........................................................................7
Install Range Hood ....................................................................... 9
Make Electrical Connection .........................................................9
Install Vent Covers (Optional) .....................................................10
Complete Installation .................................................................10
RANGE HOOD USE ......................................................................10
Range Hood Controls ................................................................10
RANGE HOOD CARE ...................................................................11
Cleaning .....................................................................................11
WIRING DIAGRAM .......................................................................12
ASSISTANCE OR SERVICE .........................................................13
In the U.S.A. ..............................................................................13
In Canada ...................................................................................13
Accessories ................................................................................13
SÉCURITÉ DE LA HOTTE DE CUISINIÈRE ...............................14
EXIGENCES D’INSTALLATION ...................................................16
Outils et pièces ...........................................................................16
Exigences d’emplacement .........................................................16
Exigences concernant l’évacuation ...........................................17
Spécications électriques ..........................................................19
INSTRUCTIONS D’INSTALLATION .............................................19
Préparation de l’emplacement ...................................................19
IInstallation de la hotte ...............................................................21
Raccordement électrique ...........................................................22
Installation des cache-conduits (facultatif) ................................23
Achever l’installation ..................................................................23
UTILISATION DE LA HOTTE .......................................................23
Commandes et caractéristiques ................................................23
ENTRETIEN DE LA HOTTE .........................................................24
Nettoyage ...................................................................................24
SCHÉMA DE CÂBLAGE ...............................................................25
ASSISTANCE OU SERVICE .........................................................26
Au Canada ..................................................................................26
Accessoires ................................................................................27
3
IMPORTANT SAFETY INSTRUCTIONS
READ
AND
SAVE
THESE
INSTRUCTIONS
For General Ventilating Use Only. Do Not Use
To Exhaust Hazardous Or Explosive Materials And Vapors.
This appliance is not intended for use by people (including
children) whose physical, sensory or mental capacities are
different or impaired or who lack the necessary experience
or knowledge/expertise to do so, unless such persons are
supervised or are trained to operate the appliance by a
person who accepts responsibility for their safety.
To Reduce The Risk Of Fire Or Electric
Shock, Do Not Use This Fan With Any Solid-State Speed
Control Device.
Ducted fans must always be vented to the outdoors.
4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Level
Drill
Drill with 1¼" (3.0 cm), 3/16" (4.8 mm), 1/8" (3.0 mm), and
5/16" (7.9 mm) drill bits
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Metric hex key set
Parts needed
Home power supply cable
1/2" (1.3 cm) UL listed or CSA approved strain relief
3 UL listed wire connectors
1 wall or roof cap
Metal vent system
Parts supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and light bulbs
installed
3¼" x 10" (8.3 x 25.4 cm) rectangular vent connector
2 metal grease lters for 30" (76.2 cm) model
3 metal grease lters for 36" (91.4 cm) model
T20
®
Torx
®†
adapter
4 - 5 x 45 mm mounting screws
6 - 4.5 x 13 mm screws
3 - 4 x 8 mm screws
4 - 10 x 50 wall anchors
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualied technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specied on the model/serial rating plate. The model/serial rating
plate is located behind the left lter on the rear wall of the vent
hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
The canopy hood is factory set for venting through the roof or
wall.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
Product Dimensions
Front View
12"
(30.5 cm)
2"
(5.1 cm)
30" (76.2 cm)
36" (91.4 cm)
23" (58.4 cm)
10"
(25.4 cm)
³⁄₈"
(1.0 cm)
(6.5 cm)
2⁹⁄₁₆"
7½"
(19.0 cm)
29¹⁄₈" (74.0 cm): 30" (76.2 cm) models
35¹⁄₈" (89.2 cm): 36" (91.4 cm) models
†®TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.
5
Back View
Cabinet Dimensions
IMPORTANT:
Minimum distance “X”: 30" (76.2 cm)
Suggested maximum distance “X”: 36" (91.4 cm)
Venting Requirements
Vent system must terminate to the outdoors.
Do not terminate the vent system in an attic or other enclosed
area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Use metal vent only. Rigid metal vent is recommended.
The length of vent system and number of elbows should be
kept to a minimum to provide efcient performance.
For the most efcient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper. If roof or wall cap has
a damper, do not use damper supplied with the range hood.
Use caulking to seal exterior wall or roof opening around the
cap.
The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air ow and a thermal break should be installed to
minimize conduction of outside temperatures as part of the vent
system. The damper should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specied CFM of
air movement. The specied CFM varies from locale to locale.
Consult your HVAC professional for specic requirements in your
area.
Venting Methods
This canopy hood is factory set for venting through the roof or
wall.
A 3¹⁄
4
" x 10" (8.3 x 25.4 cm) rectangular vent system is needed for
installation (not included). The hood exhaust opening is 3¹⁄
4
" x 10"
(8.3 x 25.4 cm). Vent system can terminate either through the roof
or wall. To vent out of the top of the range hood and through a
wall, a 90° elbow is needed. See “Install Range Hood” section for
details for installing the damper.
NOTE: Flexible vent is not recommended. Flexible vent
creates back pressure and air turbulence that greatly reduce
performance.
(3.2 cm)
1⁹⁄₃₂"
8¹⁄₈" (20.6 cm): 30" (76.2 cm) models
11" (27.9 cm): 36" (91.4 cm) models
Wiring knockout
(20.0 cm)
7⁷⁄₈"
¾"
(1.9 cm)
12³⁄₁₆" (31.0 cm): 30" (76.2 cm) models
12¹⁄₈" (30.8 cm): 36" (91.4 cm) models
13" (33.0 cm)
18" (45.7 cm)
min.
36" (91.4 cm)
clearance upper
cabinet
to countertop
countertop height
30" (76.2 cm) or 36" (91.4 cm)
cabinet opening width
(If installed between cabinets)
A
B
Min. cabinet
opening width
(if used)
X
yponac fo mottoB
to cooking surface
Duct cover
Canopy
A. 76" (193.0 cm) minimum for
installations with canopy only.
B. 88" (223.5 cm) minimum for
installations with optional
duct cover.
6
Rear discharge
This range hood can be vented directly out the back using the
3¼" x 10" (8.3 cm x 25.4 cm) rectangular damper (supplied) along
with a 3¼" x 10" (8.3 cm x 25.4 cm) rectangular vent system (not
supplied). See “Install Range Hood” section for details for
installing the damper.
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
3¹⁄
4
" x 10" (8.3 cm x 25.4 cm) Vent System
Vent Piece
3¹⁄
4
" x 10" (8.3 cm x 25.4 cm)
90° elbow
5.0 ft
(1.5 m)
3¹⁄
4
" x 10" (8.3 cm x 25.4 cm)
at elbow
12.0 ft
(3.7 m)
3¹⁄
4
" x 10" (8.3 cm x 25.4 cm) wall
cap
0.0 ft
(0.0 m)
Example vent system
Maximum Recommended Length = 35 ft (10.7 m)
1 - 90° elbow = 5.0 ft (1.5 m)
8 ft (2.4 m) straight = 8.0 ft (2.4 m)
1 - wall cap = 0.0 ft (0.0 m)
Length of 3¹⁄
4
" x 10" (8.3 cm x 25.4 cm)
system
= 13.0 ft (3.9 m)
Electrical Requirements
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 (latest
edition), or CSA Standards C22.1-94, Canadian Electrical Code,
Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes
and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualied electrician determine that the
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 V, 60 Hz, AC only, 15 A, fused electrical circuit is
required.
If the house has aluminum wiring, follow the procedure
below:
Connect the aluminum wiring using special connectors and/or
tools designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with local
codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of
the appliance as specied on the model/serial/rating plate.
The model/serial/rating plate is located behind the left lter on
the rear wall of the range hood.
Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22. 1-94, Canadian Electrical Code, Part 1 and
C22.2 No. 0-M91 (latest edition) and all local codes and
ordinances.
Roof Venting Wall Venting
(top or re
ar discharge)
A
B
A
B
A. Roof cap
B. 3¹⁄
4
" x 10" (8.3 x 25.4 cm)
rectangular metal vent
A. Wall cap
B. 3¹⁄
4
" x 10" (8.3 x 25.4 cm)
rectangular metal vent
Wall cap
3
¹⁄₄" x 10"
(8.3 x 25.4 cm)
elbow
2 ft
(0.6 m)
6 ft (1.8 m)
7
INSTALLATION INSTRUCTIONS
Prepare Location
It is recommended that the vent system be installed before
the range hood is installed.
If you are installing an optional backsplash or full width duct
cover, follow the instructions included with that product.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
Check your ceiling height and the hood height maximum
before you select your hood.
1. Disconnect power.
2. Determine which venting method to use: roof, wall, or
non-vented.
3. Select a at surface for assembling the range hood.
Place covering over that surface.
4. Using 2 or more people, lift range hood onto covered surface.
NOTE: This range hood can be mounted to the cabinets or to the
wall.
For Cabinet Installations
1. If cabinet has recessed bottom, add wood ller strips on each
side. Install screws to attach ller strips in locations shown.
Determine Wiring Hole Location
Cut only one 1¹⁄
4
" (3.2 cm) diameter wiring access hole.
See Step 2 for wiring hole location instructions.
1. Determine and clearly mark a vertical centerline on the wall
and cabinet in the area the vent opening will be made.
2. To wire through top:
Mark a line distance “A” from the left of the centerline on the
underside of the cabinet. Mark the point on this line that is 7
7
/
8
"
(20.0 cm) from back wall. Drill a 1¼" (3.2 cm) diameter hole
through the cabinet at this point.
Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm)
Rectangular Vent System
Roof Venting
To make a 3½" x 10½" (8.9 cm x 26.7 cm) rectangular cutout
on the underside of cabinet top and bottom:
1. Mark lines 3/8" (1.0 cm) and 3
7
/
8
" (9.8 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
Cabinet
Wall
bottom
3" (7.6 cm)
3" (7.6 cm)
Wood filler strips
(recessed cabinet
bottoms only)
A
A. Centerline
Centerline
7⁷⁄₈" (20.0 cm
)
from wall,
not cabinet
frame
A
A. 12³⁄
16
" (31.0 cm)
8
4. Repeat steps 1-3 for the underside of the top of the cabinet.
Wall Venting Under Cabinet
To make a 3½" x 10½" (8.9 cm x 26.7 cm) rectangle in the
wall:
1. Make 2 lines by measuring 3/8" (9.5 mm) and 3
7
/
8
" (9.8 cm)
down from underside of cabinet and mark on the centerline
on the back wall.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the wall.
Use saber or keyhole saw to cut a rectangular opening in the wall
for the vent.
3. Lift the range hood up under cabinet and determine nal
location by centering beneath cabinet. Mark on the underside
of cabinet the location of the 4 keyhole mounting slots on the
range hood. Set range hood aside on a covered surface.
4. Use 1/8" (3 mm) drill bit and drill 4 pilot holes as shown.
5. Install the 4 - 4.5 x 13 mm mounting screws in pilot holes.
Leave about 1/4" (6.4 cm) space between screw heads and
cabinet to slide range hood into place.
For Wall Installations:
1. Determine and mark the centerline on the wall where the
canopy hood will be installed.
2. Select a mounting height between a minimum of 30"
(76.2 cm) and a suggested maximum of 36" (91.4 cm) above
the range to the bottom of the hood. Mark a reference line on
the wall.
3. Using 2 or more people, center the hood on the vertical
centerline, then align the bottom of the hood with the
horizontal reference line marked on the wall.
4. Mark centers of the fastener locations to the wall. Set range
hood aside on a covered surface.
IMPORTANT: All screws must be installed into wood. If there
is no wood to screw into, additional wall framing supports
may be required.
5. Drill 3/16" (4.8 mm) pilot holes at all locations where screws
are being installed into wood.
6. Install the 2 - 5 x 45 mm mounting screws. Leave a 1/4"
(6.4 mm) gap between the wall and the back of the screw
head to slide range hood into place.
7. Determine and make all necessary cuts in the wall or ceiling
for the vent system. Install the vent system before installing
the hood. See “Venting Requirements” section.
(13.3 cm)
5¹/"
(13.3 cm)
5¹/"
(9.8 cm)
*3⁷⁄₈"
*From wall, not cabinet frame
Cabinet cutouts
*³⁄₈" (1.0 cm)
2¾"
6¾"
Cabinet
front
(7.0 cm)
(13.3 cm)
5
¹⁄₄"
5¹⁄₄"
A
A. Keyhole slot
A
A. Drill pilot hole.
¹⁄₄"
(6.4 mm)
A
C
B
X
D
A. Horizontal reference line
B. Vertical centerline
C. Mounting height
D. Cooking surface
A
A. Keyhole slot
A
A. Drill pilot hole.
¹⁄₄
"
(6.4 mm
)
9
Complete Preparation
1. Determine the required height for the home power supply
cable and drill a 1¼" (3.2 cm) hole at this location.
2. Run the home power supply cable according to the National
Electrical Code or CSA Standards and local codes and
ordinances. There must be enough 1/2" conduit and wires
from the fused disconnect (or circuit breaker) box to make the
connection in the hood’s electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
3. Remove terminal box cover and set aside.
4. Remove knockout from the top of the vent hood and install a
UL listed or CSA approved 1/2" strain relief.
Install Range Hood
1. Remove the grease lters. See the “Range Hood Care”
section.
2. Depending on your installation, remove either top or rear
rectangular vent knockout. If using round vent, remove top
rectangular knockout.
Make sure damper pivot is nearest to top/back edge of range
hood.
3. Remove tape from damper ap.
NOTE: The 3¼" x 10" (8.3 x 25.4 cm) rectangular damper can
be installed up to 1" (2.5 cm) on either side of the hood center
to accommodate off center duct work.
4. Attach the 3¼" x 10" (8.3 x 25.4 cm) rectangular vent
connector to the range hood using sheet metal screws.
NOTE: If the wall cap is directly behind the 3¼" x 10" (8.3 x
25.4 cm) rectangular vent connector, check that the damper
and the wall cap do not interfere with each other. Remove the
damper from the 3¼" x 10" (8.3 x 25.4 cm) rectangular vent
connector if they interfere.
5. Using 2 or more people, lift the hood into nal position.
Feed enough electrical wire through the ½" UL listed or CSA
approved strain relief to make connections in the terminal
box. Tighten the strain relief screws.
6. Position the range hood so that the large end of the keyhole
slots are over the mounting screws. Then, push the hood
toward the wall (for cabinet mounting) or allow the range
hood to slide down to the marked mounting height (for wall
mounting) so that the screws are in the neck of the slots.
Tighten the mounting screws, making sure the screws are
in the narrow neck of slots. (For wall mount, check that the
hood is level).
7. Connect ventwork to hood. Seal joints with clamps to make
secure and airtight.
8. Check that back draft dampers work properly.
Make Electrical Connection
1. Disconnect power.
2. Use UL listed wire connectors and connect white wires (A)
together.
A
A. Vent knockouts
A
B
C
D
C
B
E
A. Top venting
B. Sheet metal screws
C.Hinge pin
D. Vent knockouts
E. Rear venting
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
C
D
E
F
A. White wires
B. Black wires
C. UL listed wire connector
D. Green (or bare) and yellow-green ground wire
E. Home power supply cable
F. UL listed or CSA approved 1/2" strain relief
10
3. Use UL listed wire connectors and connect black wires (B)
together.
4. Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (C) in terminal box using UL
listed wire connectors.
5. Install terminal box cover.
6. Check that all light bulbs are secure in their sockets.
7. Reconnect power.
Install Vent Covers (Optional)
If you are installing an optional full width duct cover, follow the
instructions included with that product.
Complete Installation
1.
section.
2. Check the operation of the range hood blower and light. See
the “Range Hood Use” section.
NOTE:
hood, read the “Range Hood Use” section.
RANGE HOOD USE
The range hood is designed to remove smoke, cooking vapors
and odors from the cooktop area. For best results, start the hood
before cooking and allow it to operate several minutes after
the cooking is complete to clear all smoke and odors from the
kitchen.
The hood controls are located on the right-hand underside of the
range hood.
Range Hood Controls
Operating the lights
1. Turn the light switch to the Night position to use the range
hood lights as a night light.
2. Turn the light switch to the High position to turn the range
hood lights On.
3. Turn the light switch to the Off position to turn the range hood
lights Off.
Operating the blower
1.
hood on Low.
2. Turn the blower switch to the second position to turn the
range hood on Medium.
3. Turn the blower switch to the third position to turn the range
hood on Medium - High.
4. Turn the blower switch to the High position to turn the range
hood on High.
5. Turn the blower switch to the Off position to turn the range
hood blower Off.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
A. LED light control
B. Fan control
A
B
11
RANGE HOOD CARE
Cleaning
IMPORTANT:
before operating hood.
Exterior Surfaces:
To avoid damage to the exterior surface, do not use steel wool or
Always wipe dry to avoid water marks.
Cleaning Method:
Liquid detergent soap and water, or all-purpose cleanser
Wipe with damp soft cloth or nonabrasive sponge, then rinse
with clean water and wipe dry.
Metal Grease Filter
To Remove Metal Grease Filters:
1.
handles, push toward the rear of the range hood and pull
down on the front handle to remove.
2.
3.
wash in a hot detergent solution to clean.
To Reinstall Metal Grease Filters:
1.
2. Push down on the rear handle and set the front of the grease
3.
Replacing a LED Lamp
Turn off the range hood and allow the LED lamp to cool.
To avoid damage or decreasing the life of the new bulb, do
wearing cotton gloves to handle bulb.
If new lamps do not operate, make sure the lamps are inserted
correctly before calling service.
1. Disconnect power.
2. Push up on the lens and turn it counterclockwise.
3. Remove the bulb and replace it with a 120 V, 6.5 watt
maximum LED bulb with a GU10 base. Turn it clockwise
to lock it into place.
4. Repeat steps 2-3 for the other bulb if needed.
5. Reconnect power.
SE1YJB
LED LED
12
WIRING DIAGRAM
VARISTOR
BK
BK
BK
BK
BK
WH
WH
WH
WH
BU
BK
GY
RD
WH
BU
BK
WH
WH
BUBU
GY
GY
BK
BK
RD
RD
YL
YL
BR
BR
YL/GN
YL/GN
WH
BK
WH
BK
YL/GN
BK
BK
WH
WH
YL/GN
YL/
GN
WH
BK
BU
13
ASSISTANCE OR SERVICE
If you need service
Please refer to the warranty page in this manual.
If you need replacement parts
If you need to order replacement parts, we recommend that
precision used to build every new appliance.
following customer assistance telephone number or your nearest
designated service center.
In the U.S.A.
Call JennAir Customer eXperience Center toll free:
1-800-JENNAIR (1-800-536-6247) or visit our website at
www.jennair.com.
Our consultants provide assistance with:
Scheduling of service. JennAir
®
appliances designated
and provide after-warranty service anywhere in the United
States.
Referrals to local JennAir
®
appliance dealers.
Installation information.
Use and maintenance procedures.
Accessory and repair parts sales.
Specialized customer assistance (Spanish speaking, hearing
impaired, limited vision, etc.).
For further assistance
If you need further assistance, you can write to JennAir
®
Appliances with any questions or concerns at:
JennAir Brand Home Appliances
Customer eXperience Center
553 Benson Road
Benton Harbor, MI 49022-2692
Please include a daytime phone number in your correspondence.
In Canada
Call the Whirlpool Canada LP Customer eXperience Centre toll
free at 1-800-JENNAIR (1-800-536-6247) or visit our website at
www.jennair.ca.
Our consultants provide assistance with:
Scheduling of service. JennAir
®
appliances designated
and provide after-warranty service anywhere in Canada.
Referrals to local JennAir
®
appliance dealers.
Installation information.
Use and maintenance procedures.
Accessory and repair parts sales.
For further assistance
If you need further assistance, you can write to JennAir
®
Appliances with any questions or concerns at:
JennAir Brand Home Appliances
Customer eXperience Centre
200 - 6750 Century Ave.
Mississauga, Ontario L5N 0B7
Please include a daytime phone number in your correspondence.
Accessories
Backsplash with Shelves
Order part number W10285447 for 30" (76.2 cm) model
Order part number W10285448 for 36" (91.4 cm) model
Backsplash without Shelves
Order part number 8285148 for 30" (76.2 cm) model
Order part number 8284756 for 36" (91.4 cm) model
Full Width Chimney Cover
Order part number EXTKIT02ES for 30" (76.2 cm) model
Order part number EXTKIT04ES for 36" (91.4 cm) model
14
SÉCURITÉ DE LA HOTTE DE CUISINIÈRE
Risque possible de décès ou de blessure grave si vous ne
suivez pas immédiatement les instructions.
Risque possible de décès ou de blessure grave si vous
ne suivez pas les instructions.
Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et
ce qui peut se produire en cas de non-respect des instructions.
Votre sécurité et celle des autres est très importante.
Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de
toujours lire tous les messages de sécurité et de vous y conformer.
AVERTISSEMENT
DANGER
Voici le symbole d’alerte de sécurité.
Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous
et à d’autres.
Tous les messages de sécurité suivront le symbole d’alerte de sécurité et le mot “DANGER” ou
“AVERTISSEMENT”. Ces mots signifient :
15
IMPORTANTES INSTRUCTIONS DE SÉCURITÉ
LIRE ET CONSERVER CES INSTRUCTIONS
AVERTISSEMENT :
POUR RÉDUIRE LE RISQUE
D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE
BLESSURES, RESPECTER LES INSTRUCTIONS
SUIVANTES :
Utiliser cet appareil uniquement selon les modalités
d’utilisation prévues par le fabricant. Pour toute question,
contacter le fabricant.
Avant d’entreprendre une opération d’entretien ou de
nettoyage sur l’appareil, interrompre l’alimentation de
l’appareil au panneau de distribution et verrouiller ce dernier
pour empêcher tout rétablissement accidentel de
l’alimentation du circuit. Lorsqu’il n’est pas possible de
verrouiller le tableau de distribution, placer sur ce dernier
une étiquette d’avertissement bien en vue interdisant le
rétablissement de l’alimentation.
Tout travail d’installation ou câblage électrique doit être
réalisé par une personne qualifiée, dans le respect des
prescriptions de tous les codes et toutes les normes
applicables, y compris les codes du bâtiment et de
protection contre les incendies.
Ne pas faire fonctionner un ventilateur dont le cordon ou la
fiche est endommagé. Jeter le ventilateur ou le retourner à
un centre de service agréé pour examen ou réparation.
Une source d’air de débit suffisant est nécessaire pour que
la combustion et l’évacuation des gaz puissent s’effectuer
correctement par la cheminée de l’appareil à gaz, afin
d’éviter tout reflux des gaz de combustion. Respecter les
directives du fabricant de l’équipement de chauffage et les
prescriptions des normes de sécurité – comme celles
publiées par la National Fire Protection Association (NFPA)
et l’American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), ainsi que les
prescriptions des autorités réglementaires locales.
Lors des opérations de découpage et de perçage dans un
mur ou un plafond, ne pas endommager les câblages
électriques et les canalisations qui peuvent s’y trouver.
Les ventilateurs d’évacuation doivent toujours décharger
l’air vers l’extérieur.
MISE EN GARDE : Cet appareil est conçu uniquement
pour la ventilation générale. Ne pas l’utiliser pour
l’extraction de matières ou vapeurs dangereuses ou
explosives.
MISE EN GARDE : Pour réduire le risque d’incendie et
évacuer adéquatement les gaz, acheminer l’air aspiré par
un conduit jusqu’à l’extérieur – ne pas décharger l’air aspiré
dans un espace vide du bâtiment comme une cavité
murale, un plafond, un grenier, un vide sanitaire ou un
garage.
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE
D’INCENDIE, UTILISER UNIQUEMENT DES CONDUITS
MÉTALLIQUES.
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D’UN
FEU DE GRAISSE SUR LA CUISINIÈRE :
Ne jamais laisser un élément de surface fonctionner à
puissance maximale sans surveillance.Un
renversement/débordement de matière graisseuse peut
provoquer des flammes et générer de la fumée. Chauffer
l’huile à une puissance moyenne ou basse.
Veiller à toujours faire fonctionner le ventilateur de la hotte
lors de la cuisson avec une puissance élevée ou lors de la
cuisson d’un mets à flamber (à savoir crêpes Suzette,
cerises jubilées, steak au poivre flambé).
Nettoyer fréquemment le ventilateur d’extraction. Veiller à
ne pas laisser la graisse s’accumuler sur les surfaces du
ventilateur ou des filtres.
Utiliser toujours un ustensile de taille appropriée. Utiliser
toujours un ustensile adapté à la taille de l’élément
chauffant.
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE DE
BLESSURES APRÈS LE DÉCLENCHEMENT D’UN FEU DE
GRAISSE SUR LA CUISINIÈRE, RESPECTER LES
RECOMMANDATIONS SUIVANTES
a
:
Placer sur le récipient un couvercle bien ajusté, une tôle à
biscuits ou un plateau métallique POUR ÉTOUFFER LES
FLAMMES, puis éteindre le brûleur. VEILLER À ÉVITER
LES BRÛLURES. Si les flammes ne s’éteignent pas
immédiatement, ÉVACUER LA PIÈCE ET APPELER LES
POMPIERS.
NE JAMAIS PRENDRE EN MAIN UN RÉCIPIENT
ENFLAMMÉ – Vous risquez de vous brûler.
NE PAS UTILISER D’EAU ni de torchon humide – ceci
pourrait provoquer une explosion de vapeur brûlante.
Utiliser un extincteur SEULEMENT si :
– Il s’agit d’un extincteur de classe ABC, dont on connaît le
fonctionnement.
– Il s’agit d’un petit feu encore limité à l’endroit où il s’est
déclaré.
– Les pompiers ont été contactés.
– Il est possible de garder le dos orienté vers une sortie
pendant l’opération de lutte contre le feu.
a
Recommandations tirées des conseils de sécurité en cas
d'incendie de cuisine publiés par la NFPA.
AVERTISSEMENT : Pour réduire le risque d’incendie
ou de décharge électrique, ne pas utiliser ce ventilateur
avec un dispositif de réglage de la vitesse à
semi-conducteurs.
Cet appareil ne convient pas à une utilisation par des
personnes (y compris des enfants) dont les capacités
physiques, sensorielles ou mentales sont différentes ou
réduites ou qui ne possèdent pas l’expérience, les connais-
sances ou l’expertise nécessaire, à moins d’être super-
visées ou d’avoir reçu des instructions concernant l’utilisa-
tion par une personne responsable de leur sécurité.
16
EXIGENCES D'INSTALLATION
Outils et pièces
Rassembler les outils et pièces nécessaires avant d’entreprendre
l’installation. Lire et observer les instructions fournies avec
chacun des outils de la liste ci-dessous.
Outils nécessaires
Outils nécessaires
Niveau
Perceuse avec des forets 1¼" (3 cm), 3/16" (4,8 mm), 1/8"
(3 mm) et 5/18" (7,9 mm)
Crayon
Pince à dénuder ou couteau utilitaire
Mètre-ruban ou règle
Pince
Pistolet à calfeutrage et composé de calfeutrage résistant aux
intempéries
Brides de conduit d’evacuation
Scie sauteuse ou scie à guichet
Tournevis à lame plate
Cisaille de ferblantier
Tournevis Phillips
Ensemble de clés à tête hexagonale (système métrique)
Pièces nécessaires
Câble d'alimentation électrique du domicile
Serre-câble de 1/2" (12,7 mm) (homologation UL ou CSA)
3 connecteurs de ls homologués UL
1 bouche de décharge (décharge à travers le mur ou à travers
le toit)
Circuit d’évacuation métallique
Pièces fournies
Retirer les pièces de leur emballage. Vérier que toutes les pièces
sont présentes.
Auvent de hotte avec ventilateur et lampes installés
Connecteur 3¼" x 10" (8,3 x 25,4 cm) pour conduit
rectangulaire
2 ltres à graisse métalliques, pour modèle de 30" (76,2 cm)
3 ltres à graisse métalliques, pour modèle de 36" (91,4 cm)
Raccord d'adaptation Torx
®†
T20
®
4 vis de montage de 5 x 45 mm
6 vis de 4,5 x 13 mm
3 vis de 4 x 8 mm
4 chevilles d'ancrage mural de 10 x 50 mm
Exigences d'emplacement
IMPORTANT : Observer les dispositions de tous les codes et
règlements en vigueur.
Coner l'installation de la hotte à un technicien qualié. C'est
à l'installateur qu'incombe la responsabilité de respecter les
distances de séparation spéciées sur la plaque signalétique de
l'appareil. La plaque signalétique de l'appareil est située derrière
le ltre de gauche, sur la paroi arrière de la hotte.
On doit toujours installer la hotte à distance des sources de
courant d’air (fenêtres, portes et bouches de chauffage).
Respecter les dimensions indiquées pour les ouvertures à
découper dans les placards. Ces dimensions tiennent compte
des valeurs minimales des dégagements de séparation.
On doit disposer d'une prise de courant électrique reliée à la
terre. Voir la section “Spécications électriques”.
La hotte est congurée à l’usine pour une décharge à travers le
toit ou un mur.
On doit assurer l’étanchéité au niveau de chaque ouverture
découpée dans le plafond ou un mur traversé par l’équipement
de la hotte.
Installation dans une résidence mobile
L’installation de cette hotte doit satisfaire aux exigences de la
norme Manufactured Home Construction Safety Standards, Titre
24 CFR, partie 328 (anciennement Federal Standard for Mobile
Home Construction and Safety, titre 24, HUD, partie 280); lorsque
cette norme n’est pas applicable, l’installation doit satisfaire aux
critères de la plus récente édition de la norme Manufactured
Home Installation 1982 (Manufactured Home Sites, Communities
and Setups) ANSI A225.1/NFPA 501A, ou des codes locaux.
†®TORX et T20 sont des marques déposées de Acument Intellectual Properties, LLC
17
Dimensions du produit
Vue de face
Vue arrière
Dimensions du placard
IMPORTANT :
Valeur minimale de la distance “X” : 30" (76,2 cm)
Valeur maximale suggérée pour la distance “X” : 36" (91,4 cm)
Exigences concernant l’évacuation
Le système doit décharger l'air à l'extérieur.
Ne pas terminer le circuit d’évacuation dans un grenier ou
dans un autre espace clos.
Ne pas utiliser une bouche de décharge murale de 4" (10,2
cm) normalement utilisée pour un équipement de buanderie.
Utiliser un conduit métallique uniquement. Un conduit en
métal rigide est recommandé.
La longueur du système d’évacuation et le nombre de coudes
doivent être réduits au minimum pour des performances
optimales.
Pour un fonctionnement efcace et silencieux :
Ne pas utiliser plus de trois coudes à 90°.
Veiller à ce qu’il y ait une section droite de conduit d'un
minimum de 24" (61,0 cm) entre les raccords coudés, si on
doit en utiliser plus d'un.
Ne pas installer 2 coudes successifs.
Au niveau de chaque jointure du circuit d'évacuation, assurer
l'étanchéité avec les brides de serrage.
Le circuit d’évacuation doit comporter un clapet anti-reux.
Si la bouche de décharge murale ou par le toit comporte
un clapet, ne pas utiliser le clapet fourni avec la hotte de
cuisinière.
À l’aide d’un produit de calfeutrage, assurer l’étanchéité
autour de la bouche de décharge à l’extérieur (à travers le
mur ou le toit).
La taille du conduit doit être uniforme.
12"
(30,5 cm)
2"
(5,1 cm)
30" (76,2 cm)
36" (91,4 cm)
23" (58,4 cm)
10"
(25,4 cm)
³⁄₈"
(1,0 cm)
(6,5 cm)
2⁹⁄₁₆"
7½"
(19,0 cm)
29¹⁄₈" (74,0 cm): modèles 30" (76,2 cm)
35¹⁄₈" (89,2 cm): modèles 36" (91,4 cm)
(3,2 cm)
1⁹⁄₃₂"
conduit d'évacuation
8
¹⁄₈
" (20,6 cm): modèles 30" (76,2 cm)
11" (27,9 cm): modèles 36" (91,4 cm)
Opercules arrachables du
(20,0 cm)
7⁷⁄₈"
¾"
(1,9 cm
)
12³⁄₁₆" (31,0 cm):
modèles 30" (76,2 cm)
12¹⁄₈" (30,8 cm): modèles 36" (91,4 cm)
13"(33,0 cm)
36" (91,4 cm)
de hauteur jusqu'au
plan de travail
18" (45,7 cm)
de dégagement minim
um
entre le placard supérieur
et le plan de travail
(en cas d'installation entre des placards)
30" (76,2 cm), 36" (91,4 cm),
ca
vité d'encastrement
AB
X
Du bas
à la surface de cuisson
de la hotte
Cavité d'encastrement
minim
um
Hotte
Couverc
le de l'é
vent
(le cas échéant)
A. 76" (193,0 cm) minimum
pour les installations avec
hotte uniquement.
B. 88" (223,5 cm) minimum
pour les installations avec
cacheconduit facultatif.
18
Installations dans les régions au climat froid
On doit installer un clapet anti-retour supplémentaire à l’arrière
pour minimiser le reux d’air froid et incorporer un élément
d’isolation thermique pour minimiser la conduction de chaleur
par l’intermédiaire du conduit d’évacuation, de l’intérieur de la
maison à l’extérieur. Le clapet anti-retour être placé du côté air
froid de la barrière thermique.
L’élément d’isolation thermique doit être aussi proche que
possible de l’endroit où le circuit d’évacuation s’introduit dans la
partie chauffée de la maison.
Air d’appoint
Les codes locaux en bâtiment peuvent imposer l’emploi d’un
circuit de renouvellement de l’air/introduction d’air d’appoint, lors
de l’utilisation d’un circuit d’aspiration de débit supérieur à une
valeur spéciée en pieds cubes par minute. Le débit spécié en
pieds cubes par minute varie d’une juridiction à l’autre. Consulter
un professionnel des installations de chauffage ventilation/
climatisation au sujet des exigences spéciques applicables
dans la juridiction locale.
Méthodes d’évacuation
Cette hotte est congurée à l’usine pour la décharge de l’air
aspiré à travers le toit ou à travers un mur.
Pour l'installation on a besoin d'un circuit d'évacuation de
conduit rectangulaire 3¹⁄
4
" x 10" (8,3 x 25,4 cm). L'ouverture de
décharge de la hotte est 3¹⁄
4
" x 10" (8,3 x 25,4 cm). La sortie à
l’extérieur du circuit d’évacuation peut se faire à travers le toit
ou à travers un mur. Un coude à 90° est nécessaire pour aspirer
l'air du dessus de la hotte et à travers un mur. Voir la section
“Installation de la hotte” pour les détails pour l'installation d'un
clapet anti-reux.
REMARQUE : On déconseille l’emploi d’un conduit exible.
Un conduit exible peut susciter une rétro-pression et
des turbulences de l’air, ce qui réduit considérablement la
performance.
Décharge à l’arrière
L'air aspiré par la hotte peut être déchargé directement à l'arrière
à l'aide du clapet anti-reux rectangulaire 3¼" x 10" (8,3 cm x
25,4 cm) (fourni) en même temps qu'un circuit d'évacuation de
conduit rectangulaire 3¼" x 10" (8,3 cm x 25,4 cm) (non fourni).
Voir la section "Installation de la hotte" pour les détails pour
l'installation d'un clapet anti-reux.
Calcul de la longueur effective du circuit
d’évacuation
Pour calculer la longueur effective du circuit d’évacuation
nécessaire, additionner les longueurs équivalentes (en pieds ou
mètres) de tous les composants utilisés dans le système.
Système de décharge de 3¹⁄
4
" x 10" (8,3 cm x 25,4 cm)
Composant
Coude à 90° de
3¹⁄
4
" x 10" (8,3 cm x 25,4 cm)
5,0 pi
(1,5 m)
Coude plat de
3¹⁄
4
" x 10" (8,3 cm x 25,4 cm)
12,0 pi
(3,7 m)
Bouche de décharge murale
de 3¹⁄
4
" x 10" (8,3 cm x
25,4 cm)
0,0 pi
(0,0 m)
Exemple de circuit d’évacuation
Longueur maximale recommandée = 35 pi (10,7 m)
1 coude à 90° = 5,0 pi (1,5 m)
Section droite de 8 pi (2,4 m) = 8 pi (2,4 m)
1 bouche de décharge murale = 0 pi (0 m)
Longueur du système de 3¹⁄
4
" x 10"
(8,3 cm x 25,4 cm)
= 13 pi (3,9 m)
Décharge à travers le toit Décharge à travers le mur
(décharge par le dessus ou
par l'arrière)
A
B
A
B
A. Bouche de décharge sur toit
B. Conduit rectangulaire
métallique 3¹⁄
4
" x 10"
(8,3 x 25,4 cm)
A. Bouche de décharge murale
B. Conduit rectangulaire
métallique 3¹⁄
4
" x 10"
(8,3 x 25,4 cm)
Bouche de
décharg
e murale
2 pi (0,6 m)
6 pi (1,8 m)
Coude de 3
¹⁄₄" x 10"
(8,3 x 25,4 cm)
19
Spécications électriques
Observer les dispositions de tous les codes et règlements en
vigueur.
S'assurer que l’installation électrique est correcte et qu'elle
satisfait aux exigences de la plus récente édition de la norme
National Electrical Code, ANSI/NFPA 70, ou de la norme CSA
C22. 1-94, Code canadien de l’électricité, partie 1 et C22.2 n°
0-M91 (dernière édition) et de tous les codes et règlements en
vigueur.
Si les codes le permettent et si l'on utilise un conducteur distinct
de liaison à la terre, il est recommandé qu'un électricien qualié
vérie la qualité de la liaison à la terre.
Pour obtenir un exemplaire des normes des codes ci-dessus,
contacter :
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
L'appareil doit être alimenté par un circuit de 120 V CA
seulement, 60 Hz, 15 ampères, protégé par fusible.
Si le domicile possède un câblage en aluminium, suivre la
procédure ci-dessous :
1. Raccorder une section de câble en cuivre massif aux
conducteurs en queue de cochon.
2. Connecter le câblage en aluminium à la section ajoutée de
câblage en cuivre en utilisant des connecteurs et/ou des
outils spécialement conçus et homologués UL pour xer le
cuivre à l’aluminium.
Suivre la procédure recommandée par le fabricant de
connecteurs électriques. Les raccordements aluminium/
cuivre doivent satisfaire aux prescriptions des codes locaux
et de l’industrie, et être conformes aux pratiques de câblage
reconnues.
Le calibre des conducteurs et les connexions doivent
être compatibles avec les caractéristiques électriques de
l'appareil spéciées sur la plaque signalétique. La plaque
signalétique de l'appareil est située derrière le ltre, sur la
paroi arrière de la hotte.
Le calibre des conducteurs doit être conforme aux exigences
du National Electrical Code, de la plus récente édition de la
norme ANSI/NFPA 70 ou des normes CSA C22. 1-94, Code
canadien de l'électricité, partie 1 et C22.2 n° 0-M91 (édition la
plus récente) et de tous les codes et règlements en vigueur.
INSTRUCTIONS D’INSTALLATION
Préparation de l’emplacement
Il est recommandé d'installer le conduit de décharge avant de
procéder à l'installation de la hotte.
Si l'on installe un dosseret ou un cache-conduit pleine largeur
(facultatifs), suivre les instructions fournies avec ce produit.
Avant d’exécuter les découpages, vérier la disponibilité
d’un dégagement sufsant dans le plafond ou le mur pour le
conduit d’évacuation.
Avant de sélectionner la hotte à installer, mesurer la hauteur
libre sous plafond et la hauteur maximum disponible sous la
hotte.
1. Déconnecter la source de courant électrique.
2. Déterminer la méthode d’évacuation à utiliser : décharge à
travers le mur ou le toit, ou recyclage.
3. Sélectionner une surface plane pour l’assemblage de la hotte.
Placer le matériau de protection sur cette surface.
4. À l’aide de deux personnes ou plus, soulever la caisse de la
hotte et la poser sur la surface couverte.
REMARQUE : Cette hotte de cuisine peut être montée sur des
placards ou sur le mur.
Pour les installations sur des placards
1. Si le fond du placard forme une cavité, ajouter des tringles
d’appui en bois de chaque côté. Installer les vis pour xer les
tringles d’appui aux emplacements indiqués.
AVERTISSEMENT
Risque du poids excessif
Utiliser deux ou plus de personnes pour déplacer et
installer la hotte de la cuisinière.
Le non-respect de cette instruction peut causer
une blessure au dos ou d'autre blessure.
3"
3"
(7,6 cm)
(7,6 cm)
Mur
Tringles d'appui en bois
(seulement pour fond de
placard avec cavité)
Bord inf. du placard
20
Déterminer l’emplacement du trou de passage du câble
Percer seulement un trou de passage de 1¹⁄
4
" (3,2 cm) de
diamètre pour le câblage. Voir l’étape 2 pour des instructions sur
l’emplacement du trou de passage du câblage.
1. Déterminer et tracer l’axe central vertical sur le mur et le
placard dans la zone où le passage du conduit d’évacuation
sera réalisé.
Câblage à travers le sommet du placard :
Tracer une ligne à de distance “A” à gauche de l’axe central,
sur la face inférieure du placard. Sur cette ligne, marquer le point
situé à 7
7
8
" (20,0 cm) du mur arrière. Percer en ce point un trou
de 1¼" (3,2 cm) de diamètre à travers le placard.
Découpage d’ouverture pour un système d’évacuation
rectangulaire de 3¼” x 10” (8,3 cm x 25,4 cm)
Décharge à travers le toit
Découpage d’une ouverture rectangulaire de 3½" x 10½"
(8,9 cm x 26,7 cm) dans le fond et le sommet de la face
inférieure du placard :
1. Tracer des lignes à 3/8" (1,0 cm) et 3
7
/
8
" (9,8 cm) du mur
arrière, sur l’axe central de la face inférieure du placard.
2. Tracer des lignes à 5¼" (13,3 cm) de part et d’autre de l’axe
central sur la face inférieure du placard.
3. Utiliser une scie sauteuse ou une scie à guichet pour
découper l'ouverture rectangulaire pour le passage du
conduit d'évacuation.
4. Répéter les étapes 1 à 3 pour la face inférieure du sommet du
placard.
Décharge à travers le mur sous un placard
Découpage d’une ouverture rectangulaire de 3½" x 10½"
(8,9 cm x 26,7 cm) dans le mur :
1. Mesurer 2 lignes de 3/8" (9,5 mm) et 3³⁄
7
" (9,8 cm) en
descendant à partir de la face inférieure du placard et
marquer leur emplacement sur l'axe central du mur arrière.
2. Tracer des lignes à 5¼" (13,3 cm) de part et d’autre de l’axe
central sur le mur.
Utiliser une scie sauteuse ou une scie à guichet pour découper
l'ouverture rectangulaire du système d’évacuation dans le mur.
3. Soulever la hotte sous le placard et déterminer sa position
d’installation nale en la centrant sous le placard. Sur la face
inférieure du placard, marquer l’emplacement des 4 trous de
montage sur la hotte. Placer la hotte à part sur une surface
couverte.
4. À l'aide d'un foret de 1/8" (3 mm), percer 4 avant-trous tel
qu'illustré.
A
A. Axe central
A. 12
³⁄₁₆
" (31,0 cm)
A
Axe central
7⁷⁄₈" (20,0 cm) à partir
cadre du placard
du mur, et non du
(13,3 cm)
5¹/"
(13,3 cm)
5¹/"
découpées
Ouvertures
dans le placard
du cadre du placard
(9,8 cm)
*À partir du mur, et non
*3⁷⁄₈"
*³⁄₈" (1,0 cm)
2¾"
6¾"
(7,0 cm)
(17,1 cm)
Axe central
Avant du
placard
(13,3 cm)
5¹⁄₄"
(13,3 cm)
5¹⁄₄"
A
A. Trou en forme de serrure
A
A. Perçage des avant-trous
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Jenn-Air JXU9130HP Le manuel du propriétaire

Catégorie
Hottes
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues