Miller LH330361F Le manuel du propriétaire

Catégorie
Système de soudage
Taper
Le manuel du propriétaire

Ce manuel convient également à

OWNER’S MANUAL
OM-624 126 174P
200710
And Non-CE Models
Coolmate 4
1. Specifications
Recirculating Coolant System For Water-Cooled GTAW Torches And GMAW Guns
Use With Guns/Torches Rated Up To 600 Amperes
4 gal (15 L) Coolant Tank Capacity;
Maximum Cooling Capacity: 15,000 BTU/hr At 1.3 qt/min (1.2 L/min)
Dimensions: 18-3/4 in (476 mm) Long, 15-1/4 in (387 mm) Wide, 16-1/4 in (413 mm)
R f ST 1228 574 A
Dimensions: 18 3/4 in (476 mm) Long, 15 1/4 in (387 mm) Wide, 16 1/4 in (413 mm)
Weight: 44 lb (20 kg)
Ref. ST-1228 574-A
115 Volts, 5.2 Amperes, 50/60, Single-Phase Input Power
2. Safety Symbol Definitions
DANGER! Indicates a hazardous situation which, if not
avoided, will result in death or serious injury. The possible
hazards are shown in the adjoining symbols or explained
in the text.
DANGER! Indique une situation dangereuse qui si on
l’évite pas peut donner la mort ou des blessures graves. Les
dangers possibles sont montrés par les symboles joints ou
sont expliqués dans le texte.
Have only trained and qualified persons install, operate,
or service this unit. Call your distributor if you do not un-
derstand the directions. For WELDING SAFETY and
EMF information, read wire feeder and welding power
source manuals.
L’installation, l’exploitation et l’entretien de cet appareil
doivent être confiés uniquement à des personnes
qualifiées et convenablement formées. S’adresser à un
distributeur si l’on ne comprend pas les directives. Pour
des renseignements ayant trait à la SÉCURITÉ lors du
soudage et aux champs électromagnétiques, consulter
les manuels traitant les dévidoirs et les sources de
courant pour le soudage.
Beware of electric shock from wiring.
Attention! Risque d’électrocution due au contact avec des
fils.
Beware of moving parts.
Attention! Pièces en mouvement.
Wear safety glasses with side shields.
Porter des lunettes de sécurité avec protections
latérales.
Recycle or dispose of used coolant in an environmentally
safe way.
Recycler ou éliminer tout liquide de refroidissement usé
conformément aux méthodes prescrites pour assurer la
protection de l’environnement.
OM-624 Page 2
3. Warning Label Definitions For CE Products
S-180 663
1 2 3 4 5
6
7 8 9
1 Warning! Watch Out! There are
possible hazards as shown by the
symbols.
2 Electric shock from wiring can kill.
3 Disconnect input plug or power before
working on machine.
4 Moving parts, such as fans, can cut
fingers and hands and cause injury.
Keep away from moving parts.
5 Wear safety glasses with side shields.
6 Read the Owner’s Manual before
working on this machine.
7 Read the labels on the welding power
source, wire feeder, or other major
equipment for welding safety
information.
8 Recycle or dispose of used coolant in
an environmentally safe way.
9 Do not remove or paint over (cover)
the label.
4/96
S-178 910
=
043 810 (HF)
043 809 (AL)
100 h. std.
21 3
6
4
7
5
1 Warning! Watch Out! There are
possible hazards as shown by the
symbols.
2 Disconnect input plug or power before
working on machine.
3 Wear safety glasses with side shields.
4 Plugged filter or hoses cause
overheating and damage.
5 Read Owner’s Manual.
6 Check and clean filter every 100
hours; also check condition of hoses.
7 Use Low Conductivity Coolant No. 043
810 for High-Frequency assisted or
Gas Tungsten Arc Welding
applications. Use Aluminum Protecting
Coolant No. 043 809 where coolant
contacts aluminum parts or for Gas
Metal Arc Welding applications or
where High Frequency is not used.
OM-624 Page 3
1 Warning! Watch Out! There
are possible hazards as
shown by the symbols.
2 Moving parts, such as fans,
can cut fingers and hands and
cause injury. Keep away from
moving parts.
4/96
S-176 106
1
2
4. Rating Label
INPUT
NRTL/C
VOLTS
AMPERES
KW
PHASE HERTZ
SERIAL NO.
STOCK NO.
EVIDENCE OF LABEL TAMPERING VOIDS WARRANTY
KJ306576
042288
115VAC
5.2A
1 (Single) 50/60Hz
COOLMATE 4
LR5071
S-165 371
5. Symbols And Definitions
. Some symbols are found only on CE products.
A
Amperes Alternating Current
U
1
Primary Voltage Single Phase
V
Volts
Water (Coolant) In-
put
Water (Coolant)
Output
Line Connection
Hz
Hertz
IP
Degree Of
Protection
I
1
Primary Current
OM-624 Page 4
6. Preparing Cooling Unit For Use
137 378-A / 160 554
1 Coolant Out Fitting
2 Coolant In Fitting
Fittings have 5/8-18 left-hand
threads.
Use table to select proper coolant,
and fill tank. Maintain coolant level
at approximately 1 in (25 mm) from
filler neck.
Unit turns On when plugged in.
Tools Needed:
5/8 in
12
Low Conductivity Coolant
No. 043 810**;
Distilled Or Deionized Water
OK Above 32° F (0° C)
Low Conductivity Coolant
No. 043 810**; Or
Aluminum Protecting Coolant
No. 043 809**;
Distilled Or Deionized Water
OK Above 32° F (0° C)
GTAW Or Where
HF* Is Used
GMAW Or Where
HF* Is Not Used
Application
*HF: High Frequency Current
**Coolants 043 810 and 043 809 protect to -37° F (-38°C) and resist algae growth.
Coolant
Aluminum Protecting
Coolant No. 043 809**
Where Coolant Contacts
Aluminum Parts
OM-624 Page 5
7. Connections
160 556 / 160 555-B
To prevent overheating, make sure
cooling unit is positioned so airflow
is not restricted.
NOTICE If welding power source
has a water valve, do not connect
hoses to water valve. Connect
hoses as shown.
GTAW Connections
GMAW Connections
OM-624 Page 6
8. Routine Maintenance
! Disconnect power
before maintaining.
1 Month
Clean Coolant Filter
Blow Out
Radiator Fins
6 Months
Replace
Cracked
Hoses
Replace
Unreadable
Labels
Change
Coolant (If
Using Water)
12 Months
Oil Motor
Change
Coolant (If
Using 043 810
Or 043 809
Coolant)
9. Coolant Maintenance
160 559
1 Coolant Filter
Remove nut to remove filter. Clean
filter and reinstall.
Changing coolant: Drain coolant by
tipping unit. Fill with clean water and
run for 10 minutes. Drain and refill.
. If replacing hoses, use hoses
compatible with ethylene gly-
col, such as Buna-n, Neo-
prene, or Hypalon. NOTE:
Oxy-acetylene hoses are not
compatible with any product
containing ethylene glycol.
1
15/16 in
Tools Needed:
OM-624 Page 7
Tools Needed:
10. Oiling Motor
Ref. 160 557 / Ref. 801 195-A
1 Wire Form
2 Radiator
. Wear gloves when handling ra-
diator.
Remove wire form. Pull radiator out
far enough to turn it to the side as
shown.
3 Motor
Remove plugs and put about 15
drops of SAE 20 motor oil into each
oil port. Replace plugs, and reas-
semble unit.
7/16 in
1
2
3
Tools Needed:
11. Adjusting Relief Valve
160 558-A
. Relief valve is factory set at 60
psi (414 kPa), and normally
needs no adjustment: Only ad-
just if replacing motor.
1 Pressure gauge
2 Relief Valve Adjustment
Screw
Connect gauge to Coolant Out fit-
ting as shown. Block or plug any
output fitting on gauge.
Turn On power, and adjust pres-
sure adjustment screw as needed.
Turn Off power. Disconnect gauge
and reinstall nut.
3/4 in
2
1
IncreaseDecrease
OM-624 Page 8
12. Troubleshooting
Trouble Remedy
Coolant system does not work. Be sure input power cord is plugged in to energized receptacle.
Check line fuses or circuit breaker, and replace or reset if necessary.
Motor overheated. Unit starts running when motor has cooled.
Have Factory Authorized Service Agent check motor.
Decreased or no coolant flow. Add coolant.
Check for clogged hoses or coolant filter.
Disconnect pump, and check for sheared coupling. Replace coupling if necessary.
187 313
Figure 12-1. Circuit Diagram
OM-624 Page 9
13. Parts List
131 764-G
1
2
3
6
7
8
9
Includes
Items
10&11
3
12
13
14
15
17
3
10
11
18
20
19
21
22
4
11
10
24
25
26
27
3
4
4
Figure 13-1. Complete Assembly
OM-624 Page 10
Description Quantity
Part
No.
Figure 13-1. Complete Assembly
Item
No.
1 124 377 WIRE FORM, radiator end 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 127 904 RADIATOR, coolant tank w/weatherstripping (includes) 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
124 374 RADIATOR, coolant tank 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
159 594 WEATHERSTRIPPING, adh .250 x .750 x 3ft 4 in 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 228 531 HOSE, rubber braided .375 ID X .650 OD X 12.000 SAE J20R3CLASS D2 2. . . . . . . . . . . . . .
4 236 084 HOSE, rubber braided .375 ID X .650 OD X 10.500 SAE J20R3CLASS D22. . . . . . . . . . . . . .
6 188 980 LABEL, caution incorrect coolant (non-CE and generic models) 1. . . . . . . . . . . . . . . . . . . . . . . . . . .
6 178 910 LABEL, caution incorrect coolant (CE models only) 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 121 316 LABEL, warning general precautionary (non-CE and generic models) 1. . . . . . . . . . . . . . . . . . . . . .
7 180 663 LABEL, warning general precautionary (CE models only) 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 166 608 CAP, tank screw-on w/screw type vent 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 +139 154 TANK, coolant (includes) 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 124 253 BUSHING, tank fuel 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11 124 621 FITTING, hose brs barbed 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12 130 633 INSULATOR, panel front 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13 601 881 NUT, stl hex jam .500-20 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 231 241 WASHER, tooth .512 ID x .900 OD 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 137 378 PLATE, ident 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 149 356 FITTING, hose brs barbed elb M 3/8tbg 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 173 263 MOTOR, 1/4HP 115VAC 50/60 Hz 1425/1725RPM dual sha 1. . . . . . . . . . . . . . . . . . . . . . . . . . .
19 177 246 PUMP, coolant (includes) 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20 5523 FITTING, hose brs barbed elb M 3/8tbg x 3/8NPT 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21 134 795 COUPLER, drive pump 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
146 249 STRAINER, screen 100 x 90 mesh 2.125 lg x .687 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22 144 649 CABLE, pwr 115V 16ga 3/c 13ft w/strain relief 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24 194 099 BRACKET, mtg motor 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25 129 484 LABEL, warning moving parts can cause serious injury 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26 132 987 BLADE, fan 10 in 6wg 23deg .500 bore CCW 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27 026 653 TUBING, phenelic .531 ID x .875 OD x .687 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS.
dec_cooler_1/07
© 2007 MILLER Electric Mfg. Co.
Declaration of Conformity for
European Community (CE) Products
. This information is provided for units with CE certification (see rating label on unit).
Manufacturer: European Contact:
Miller Electric Mg. Co. Mr. Danilo Fedolfi,
1635 W. Spencer St. Managing Director
Appleton, WI 54914 USA ITW Welding Products Italy S.r.l.
Phone: (920) 734-9821 Via Privata Iseo 6/E
20098 San Giuliano
Milanese, Italy
Phone: 39(02)98290-1
Fax: 39(02)98290203
European Contact Signature:
Declares that the product: COOLMATE 4
conforms to the following Directives and Standards:
Directives
Electromagnetic compatibility Directives: 89/336/EEC, 92/31/EEC
Low Voltage Directive: 73/23/EEC
Machinery Directives: 89/392/EEC, 91/368/EEC, 93/C 133/04, 93/68/EEC
Standards
Electromagnetic compatibility (EMC) Product standard for arc welding equipment: EN50199: August 1995
Safety Requirements for Arc Welding Equipment part 1: EN 60974-1: 1989
Arc Welding Equipment Part 1: Welding Power Sources: IEC 9741 (April 1995 Draft Revision)
Degrees of Protection provided by Enclosures (IP code): IEC 529: 1989
The product technical file is maintained by the responsible Business Unit(s) located at the manufacturing facility.
S/N: KG085472
042288
115
5.2
COOLMATE 4
Hz50/60
IP 23
MILLER ELECTRIC MFG. CO., APPLETON, WI USA
V
U
1
=
A I
1
=
1
Notes
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Miller LH330361F Le manuel du propriétaire

Catégorie
Système de soudage
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues