KitchenAid KGCD807XBL01 Guide d'installation

Taper
Guide d'installation

Ce manuel convient également à

30" (76.2 CM) GAS DOWNDRAFTCOOKTOP
INSTALLATIONINSTRUCTIONS
INSTRUCTIONSD'IlblSTALL_TIONDE LATABLEDE
CUISSON A GAZ A ASPIRATION
PARLEBASDE 30" (76,2 CM)
TableofContents/Tabledes mah_res
COOKTOP SAFETY ........................................................................ 2
INSTALLATION REQUIREMENTS ................................................ 3
Tools and Parts ............................................................................ 3
Location Requirements ................................................................ 3
Venting Requirements .................................................................. 5
Venting Methods .......................................................................... 6
Electrical Requirements ............................................................... 8
Gas Supply Requirements ........................................................... 8
INSTALLATION INSTRUCTIONS ................................................ 10
Install Cooktop ........................................................................... 10
Rotate Blower- Optional ............................................................ 10
Make Gas Connection ................................................................ 11
Electronic Ignition System .......................................................... 12
Complete Installation.................................................................. 13
SleCURITle DE LA TABLE DE CUlSSON ................................. 13
EXIGENCES D'INSTALLATION ................................................ 14
Outils et pieces........................................................................ 14
Exigences d'emplacement ...................................................... 15
Exigences concernant I'evacuation ........................................ 16
Methodes d'evacuation ........................................................... 17
Specifications electriques ....................................................... 19
Specifications de I'alimentation en gaz .................................. 20
INSTRUCTIONS D'INSTALLATION ......................................... 21
Installation de la table de cuisson ........................................... 21
Rotation du ventilateur- Facultative ....................................... 22
Raccordement au gaz ............................................................. 22
Systeme d'allumage electronique ........................................... 24
Achever I'installation ............................................................... 24
iMPORTANT:
Installer: Leave installation instructions with the homeowner.
Homeowner: Keep installation instructions for future reference.
iMPORTANT :
Installateur : Remettre les instructions d'installation au propri6taire.
Propri6taire : Conserver les instructions d'installation pour r6f6rence ult6rieure.
W10305290A
COOKTOP SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
WARNING: If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death,
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance,
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or
the gas supplier,
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the "What to do if you smell gas" instructions.
In the State of Massachusetts, the following installation instructions apply:
[] Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
[] If using a ball valve, it shall be a T-handle type.
[] A flexible gas connector, when used, must not exceed 3 feet.
2
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Tape measure 1¼.drill bit
Flat-blade screwdriver Jigsaw
Phillips head screwdriver Ratchet with 3/8"socket
Drill Pipe-joint compound
resistant to LP gas
Level
Marker or pencil Noncorrosive leak-detection
solution
Pliers
Parts supplied
Vent grill Burner caps
Pre-filter Burner grates
LP conversion kit Pressure regulator
Parts needed
Metal ducting
Vent clamps
Wall cap
6" (15.2 cm) Round Surface Wall Cap Damper
Order Part Number A406
5" (12.7 cm) Round Surface Wall Cap Damper
Order Part Number A405
31¼"x 10" (8.3 x 25.4 cm) Surface Wall Cap Damper
Order Part Number A403
To order, see the "Assistance or Service" section of the Use
and Care Guide.
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See "Electrical Requirements" and
"Gas Supply Requirements" sections.
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
IMPORTANT: Observe all governing codes and ordinances.
When installing cooktop, use minimum dimensions given.
It is the installer's responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located on side of the downdraft
plenum.
To eliminate the risk of burns or fire by reaching over the
heated surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage is to
be provided, the risk can be reduced by installing a range
hood that projects horizontally a minimum of 5" (12.7 cm)
beyond the bottom of the cabinets.
The cooktop should be installed in a location away from
strong draft areas, such as windows, doors and strong
heating vents or fans.
All openings in the wall or floor where cooktop is to be
installed must be sealed.
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
Grounded electrical supply is required. See "Electrical
Requirements" section. Proper gas supply connection must
be available. See "Gas Supply Requirements" section.
The cooktop is designed to hang from the countertop by its
side or rear flanges.
The gas and electric supply should be located as shown in
"Cabinet Dimensions" section so that they are accessible
without requiring removal of the cooktop.
Provide cutout in right rear corner of cutout enclosure as
shown to provide clearance for gas inlet, power supply cord,
and to allow the rating label to be visible.
If cabinet has drawers, drawers will need to be removed and
drawer fronts installed on front of cabinet.
IMPORTANT: An undercounter built-in oven cannot be installed
under this product.
IMPORTANT: To avoid damage to your cabinets, check with your
builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage.
Mobile Home - Additional Installation Requirements
The installation of this cooktop must conform to the
Manufactured Home Construction and Safety Standard, Title 24
CFR, Part 3280 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD Part 280). When such
standard is not applicable, use the Standard for Manufactured
Home Installations, ANSI A225.1/NFPA 501A or local codes.
In Canada, the installation of this cooktop must conform with
the current standards CAN/CSA-A240-1atest edition, or with
local codes.
Product Dimensions
30" (76.2 cm) Cooktop
Cabinet Dimensions
A. 2137/64'' (54.8 cm) with stainless steel trim or
21V2" (54.6 cm) without stainless steel trim
B. 1947/64'' (50.1 cm) screw head to screw head
C. Model/serial rating/clearance plate location
A. 291_,, (76.1 cm) without
stainless steel trim
B. 30 _2" (76.3 cm) with
stainless steel trim
C. 122_4 ''(31.6 cm) centerline of
cooktop to centerline of gas
manifold pipe
D. 7_" (18.6 cm)
E.3 _4" (9.2 cm)
F.15"(38.1cm)
G. 2_2" (5.5 cm) recommended
minimum cabinet to motor
clearance
H. 141_2" (36.4 cm)
I. 114_4" (29.9 cm)
J. 28_" (72.1 cm) screw head to
screw head
C
A. 30" (76.2 cm)
B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop platform
and bottom of uncovered wood or metal cabinet (24" [61.0 cm]
minimum clearance if bottom of wood or metal cabinet is covered
by not less than ¼" [0.6 cm] flame retardant millboard covered with
not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless
steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
D. 13" (33.0 cm) recommended upper cabinet depth
E.2 _" (5.4cm)
F. 191_ '' (50.6cm)
G. 18" (45. 7cm) minimum clearance from upper cabinet to countertop
within minimum horizontal clearances to cooktop
H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of
countertop
I. Junction box or outlet; 10" (25.4 cm) from right-hand side of
cabinet
J. 28 _" (72.7cm) on 30" (76.2 cm) models
K. 8" (20.3 cm) minimum distance to nearest left and right side
combustible surface above cooktop
L. 2" (5.1 cm) minimum clearance between back wall and countertop
M. Gas line opening - Walh anywhere 6" (15.2 cm) below underside of
countertop on the left side. Cabinet floor: anywhere within
6" (15.2 cm) of rear wall on the left side is recommended.
N. 25" (63.5 cm) depth of countertop
NOTES: After making the countertop cutout, some installations
may require notching down the base cabinet side walls to clear
the cooktop base. To avoid this modification, use a base cabinet
with sidewalls wider than the cutout.
A minimum side clearance of 6" (15.2 cm) is recommended
between side of cooktop and side wall for maximum
ventilation performance.
A minimum clearance of 2" (5.1 cm) is recommended
between the motor/blower and cabinet for proper cooling. A
6" (15.2 cm) clearance is recommended for servicing access.
Cutout Dimensions
A
A. 28 _" (72.7 cm) maximum
B. 19 '_" (50.6 cm) maximum
C. 9_" (21.6 cm)
D. 64_4 '' (17.2 cm)
E. 2 _" (5.4 cm) minimum space to front edge of cooktop
F Floor exhaust option
G. 6 _" (15.6 cm) for 6" (15.2 cm) vent system and 5 _" (13.1 cm) for
5" (12. 7cm) vent system
H. 9_" (21.6 cm)
I. 13_" (33.9 cm) from the top of the countertop surface
J. Waft exhaust option
IMPORTANT: This cooktop must be exhausted outdoors.
Do not terminate the vent system in an attic or other enclosed
area.
Use a vent cap.
Vent system must terminate to the outside.
Use only a 6" (15.2 cm) diameter round or 3 1¼,,x 10"
(8.3 x 25.4 cm) rectangular vent except as follows: For gas
models, a 5" (12.7 cm) diameter round vent must be used if
the duct length is 10 ft (3.0 m) or less.
Before making cutouts, make sure there is proper clearance
within the wall or floor for the exhaust vent.
Do not cut a joist or stud unless absolutely necessary. If a
joist or stud must be cut, then a supporting frame must be
constructed.
The size of the vent should be uniform.
The vent system must have a damper. If roof or wall cap has a
damper, do not use damper supplied with the range hood.
Use vent clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the
cap.
Determine which venting method is best for your application.
For Best Performance:
Use 26-gauge minimum galvanized or 25-gauge minimum
aluminum metal vent. Poor quality pipe fittings can reduce
airflow. Flexible metal vent is not recommended.
NOTE: Local codes may require a heavier gauge material.
Metal duct may be reduced to 30-gauge galvanized steel or
26-gauge aluminized steel if allowed by local codes. This
reduction is based on information in the International
Residential Codes Section M1601.1 (2006 edition).
Do not install 2 elbows together.
Use no more than three 90° elbows.
If an elbow is used, install it as far away as possible from the
hood's vent motor exhaust opening.
Make sure there is a minimum of 18" (45.7 cm) of straight
vent between the elbows if more than one elbow is used.
Elbows too close together can cause excess turbulence that
reduces airflow.
Do not use a 5" (12.7 cm) elbow in a6" (15.2 cm) or 31/4"x 10''
(8.3 x 25.4 cm) system.
Do not reduce to a 5" (12.7 cm) system after using
6" (15.2 cm) or 31/4'' x 10" (8.3 x 25.4 cm) fittings.
Avoid forming handmade crimps. Handmade crimps may
restrict airflow.
Use the wall caps listed in the "Tools and Parts" section for
best performance. If an alternate wall or roof cap is used, be
certain the cap size is not reduced and that it has a back draft
damper.
Use vent clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the
cap.
The length of vent system and number of elbows should be kept
to a minimum to provide efficient performance.
The maximum equivalent length of the vent system is 60 ft
(18.3 m). For altitudes above 4,500 ft (1272 m), reduce
recommended vent run by 20% for best performance.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break installed to minimize
conduction of outside temperatures as part of the vent system.
The damper should be on the cold air side of the thermal break.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
Common venting methods are shown fora counter-mounted Concrete Slab Installations -
downdraft cooktop. The cooktop may be vented through the wall Exhaust Through Window Well
or floor.
B
Option I - Roof Venting Option 2 - Wall Venting
A. Roof cap
B. 6" (15.2 cm) round roof venting
Option 3 - Venting Between
Floor Joist
:'A "B
A. Wall cap
B. 6" (15.2 cm) round wall venting
B
\
A ¸
A. 6" (15.2 cm) round wall venting
B. Wall cap
Option 4 - Venting behind
Cabinet Kick Plate
(8"3W' x 10"
25,4 cm)
A B
A. Wall cap
B. 6" (15.2 cm) round wall venting
A. Wall cap
B. 12" (30.5 cm) minimum
C. Concrete slab
D. 6" (15.2 cm) round PVC sewer pipe
E. 5" to 6" (12.7 cm to 15.2 cm) transition
F. 6" (15.2 cm) round metal duct
G. 6" (15.2 cm) round PVC coupling
H. 6" (15.2 cm) round PVC sewer pipe
I. 6" (15.2 cm) round 90 ° PVC sewer pipe elbow
J. Tightly pack gravel or sand completely around pipe.
K. 42 ft (12.8 m) max.
L. 6" (15.2 cm) round PVC coupling
M. 6" (15.2 cm) minimum
N. Window well
Concrete
Slab Installations - Exhaust Through Wall
B
A D
0
F
M
K
A. Wall cap
B. 6" (15.2 cm) round metal vent
C. 16" (40.6 cm) maximum
D. 6" (15.2 cm) round PVC sewer pipe
E. 5" to 6" (12.7 cm to 15.2 cm) transition
F. 6" (15.2 cm) round metal duct
G. 6" (15.2 cm) round PVC coupling
H. Concrete slab
I. 6" (15.2 cm) round PVC sewer pipe
J. 6" (15.2 cm) round 90 ° PVC sewer pipe elbow
K. Tightly pack gravel or sand completely around pipe.
L. 30 ft (9.1 m) max.
M. 6" (15.2 cm) round 90 ° PVC sewer pipe elbow
N. 6" (15.2 cm) round PVC coupling
O. 12" (30.5 cm) minimum
6
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Vent Piece 6" (15.2 cm) Round
45° elbow 2.5 ft
(0.8m)
90° elbow 5.0 ft
(1.5m)
6" (15.2 cm) 0.0 ft
wall cap (0.0 m)
31/4"x 10" (8.3 cm x 25.4 cm) 4.5 ft
to 6" (15.2 cm) transition (1.4 m)
6" (15.2 cm) to 31/4'' x 10" 1 ft
(8.3 cm x 25.4 cm) transition (0.3 m)
31/4"x 10" (8.3 cm x 25.4 cm) 9.0 ft
to 6" (15.2 cm) 90° elbow (2.7 m)
transition
6" (15.2 cm) to 31/4'' x 10" 5.0 ft
(8.3 cm x 25.4 cm) 90° elbow (1.5 m)
transition
31/4"x 10" (8.3 cm x 25.4 cm) 5.0 ft
90° elbow (1.5 m)
Example vent system
90 ° embow
(
6ft (1.8m)
wall cap
1- 90 ° elbow = 5 ft (1.5 m)
8 ft (2.4 m) straight = 8 ft (2.4 m)
1 - wall cap = 0 ft (0 m)
System length = 13 ft (3.9 m)
NOTE: Flexible vent is not recommended. Flexible vent creates
back pressure and air turbulence that greatly reduce
performance.
Determine Range Blower Setting
This cooktop is equipped with a dual range blower. It is shipped
from the factory in the low range for most installations. If the
equivalent duct length exceeds 30 ft (9.1 m), it must be converted
to high range. Do not convert the blower to high range for shorter
lengths; this will cause excessive noise and conditioned air loss.
Convert blower before installing into countertop if necessary.
To Convert to High Range:
1. Place cooktop on floor with front edge and plenum down.
2. Remove the four #10 - 32 Iocknuts (A) that attach the blower
motor assembly to the blower exhaust scroll.
3. Remove the blower motor assembly (B) from the blower
exhaust scroll (E).
4. Slowly reach into the blower exhaust scroll opening and
remove the retainer (C).
5. Gently remove the restrictor ring (D).
6. Place the motor assembly back on the studs of the blower
exhaust scroll.
7. Reattach the four #10-32 Iocknuts to secure the blower motor
assembly back to the blower exhaust scroll.
31/4'' x 10" (8.3 cm x 25.4 cm) 12.0 ft
flat elbow (3.7 m)
31/4'' x 10" (8.3 cm x 25.4 cm) 0.0 ft
wall cap (0.0 m)
5" to 6" (12.7 cm to 15.2 cm) 1 ft
transition (0.3 m)
AB C D E F
A. #10 - 32 Iocknut
B. Blower motor and wheel assembly
C. Retainer
D. Restrictor ring
E. Exhaust scroll
F. Blower wheel guard
IMPORTANT: The cooktop must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70
or Canadian Electrical Code, CSA C22.1.
This cooktop is equipped with an electronic ignition system that
will not operate if plugged into an outlet that is not properly
polarized.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is
required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this cooktop be provided.
Electronic ignition systems operate within wide voltage limits,
but proper grounding and polarity are necessary. Check that
the outlet provides 120-volt power and is correctly grounded.
The wiring diagrams are provided with this cooktop. See
"Wiring Diagrams" on a separate sheet. The wiring diagrams
are located on the left underside of the cooktop base.
Explosion Hazard
Use a new CSA International approved gas supply line.
install a shut-off valve.
Securely tighten all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Type of Gas
Natural Gas:
This cooktop is design-certified by CSA International for use with
Natural gas or, after proper conversion, for use with LP gas.
This cooktop is factory set for use with Natural gas. If
converting to LP gas, see the "LP Gas Conversion"
instructions provided in the package containing literature.
The model/serial rating plate located on the underside of the
cooktop base has information on the types of gas that can be
used. If the types of gas listed do not include the type of gas
available, check with the local gas supplier.
LP Gas Conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the cooktop from the gas
specified on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier. See the Gas
Conversion instructions provided in the package containing
literature.
Gas Supply Line
Provide a gas supply line of 3/4"(1.9 cm) rigid pipe to the
cooktop location. A smaller size pipe on longer runs may
result in insufficient gas supply. Pipe-joint compounds that
resist the action of LP gas must be used. Do not use
TEFLON ®_tape. With LP gas, piping or tubing size should be
1/2,,minimum. Usually, LP gas suppliers determine the size
and materials used in the system.
Flexible metal appliance connector:
If local codes permit, use a V_"or 3/4"I.D. flexible stainless
steel tubing gas connector, designed by CSA to connect
the cooktop to the rigid gas supply line.
A 1/2,,male pipe thread is needed for connection to the
female pipe threads of the inlet to the cooktop pressure
regulator.
Do not kink or damage the flexible metal tubing when
moving the cooktop.
Rigid pipe connection:
The rigid pipe connection requires a combination of pipe
fittings to obtain an in-line connection to the cooktop. The
rigid pipe must be level with the cooktop connection. All
strains must be removed from the supply and fuel lines so
cooktop will be level and in line.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest
edition.
IMPORTANT: Leak testing of the cooktop must be conducted
according to the manufacturer's instructions.
1-®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
8
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff
valve. This valve should be located in the same room but
external to the cooktop opening, such as an adjacent
cabinet. It must be accessible without removing the cooktop,
and it should be in a location that allows ease of opening and
closing. Do not block access to shutoff valve. The valve is for
turning on or shutting off gas to the cooktop.
B
//
A. Gas supply line
B. Shutoff valve "open" position
C. To cooktop
Gas Pressure Regulator
The gas pressure regulator supplied with this cooktop must be
used. The inlet pressure to the regulator should be as follows for
proper operation:
Natural Gas:
Minimum pressure: 5" (12.7 cm) WCP
Maximum pressure: 7" to 14" (17.8 cm to 35.5 cm) WCP
LP Gas:
Minimum pressure: 10" (25.4 cm) WCP
Maximum pressure: 14" (35.5 cm)WCP
Contact local gas supplier if you are not sure about the inlet
pressure.
Burner Input Requirements
Input ratings shown on the model/serial rating plate are for
elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings should be
reduced at a rate of 4% for each 1,000 ft (304.8 m) above sea
level (not applicable for Canada).
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least
1" water column pressure above the manifold pressure shown on
the model/serial rating plate.
Line pressure testing above 1/2psi gauge (14" WCP)
The cooktop and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2psi (3.5 kPa).
Line pressure testing at 1/2psi gauge (14" WOP) or lower
The cooktop must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to
or less than 1/2psi (3.5 kPa).
INSTALLATIONINSTRUCTIONS
Decide on the final location for the cooktop.
Excessive Weight Hazard
Use two or more people to move and install cooktop.
Failure to do so can result in back or other injury.
1=
2.
3.
4.
S
Open carton as instructed on product packaging.
Remove shipping materials and tape from cooktop.
Remove the removable grease filter by lifting the filter out.
For island or peninsula installations, go to the "Rotate Blower
- Optional" section.
D
C
,j/
/
A
A. Removable grease filter
B. Left side grate
C. Vent grille
D. Right side grate
5. Using 2 or more people, remove the cooktop from the carton.
REMEMBER: An undercounter built-in oven cannot be
installed under this cooktop.
6. Place cooktop right side up into the cutout.
NOTE: Make sure that the front edge of the cooktop is
parallel to the front edge of the countertop. If repositioning is
needed, lift entire cooktop up from the cutout to avoid
scratching the countertop.
7. Connect blower exhaust scroll to ducting.
8. Use vent clamps to secure the ducting to the blower exhaust
scroll.
9. Reinstall grease filter.
10. Reinstall vent grille.
IMPORTANT: The following additional steps must be performed
if the product is being installed in peninsula or island cabinetry.
The blower exhaust scroll is shipped from the factory set to
exhaust straight out the back of the cabinet through an exterior
wall.
D_ Z........
c .....\
A. Blower exhaust scroll
B. Plenum
C. Blower motor
D. #10-32 Iocknuts (4)
E.Motor mounting plate
To rotate blower:
1. Remove the right and left grates. Then remove the vent grille.
See illustration in Step 4 of the "Install Cooktop" section.
2. Locate the 4 Iocknuts inside the plenum.
i
D
3.
A. #10 - 32 Iocknut
B. Plenum
C. Flat washer
D. Blower guard
Use 3/8"socket and ratchet handle to loosen the nut half of a
rotation. Repeat this process for each of the 4 nuts.
10
4. With the nuts loosened, the blower exhaust scroll can be Typical flexible connection.
easily rotated downward.
5. Retighten each nut with the 3/8"socket, extension and ratchet.
Explosion Hazard
Use a new CSA International approved gas supply line.
install a shut=off valve.
Securely tighten all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
1. Apply pipe-joint compound made for use with Natural and LP
gas to the smaller thread ends of the flexible connector
adapters (see C and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
3. Use a 1%e"combination wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked.
;Q
E ......................................
A. Manifold entrance
B. Gas pressure regulator
C. Use pipe-joint compound.
D. Adapter (must have Y2"male pipe thread)
E.Flexible connector
F Adapter
G. Use pipe-joint compound.
H. Manual gas shutoff valve
I. Y2"or 3/4"gas pipe
4.
H .......................................(_
Install the pressure regulator with the arrow pointing up
toward the bottom of the cooktop base and in a position
where you can reach the regulator access cap.
A
C
A. Access cap
B. Rear of cooktop
C. Gas pressure regulator
D. Up arrow. Regulator must be installed with
arrow pointing up to cooktop bottom.
IMPORTANT: All connections must be wrench-tightened. Do
not make connections to the gas regulator too tight. Making
the connections too tight may crack the regulator and cause
a gas leak. Do not allow the regulator to turn on the pipe
when tightening fittings.
Use only pipe-joint compound made for use with Natural and LP
gas.
Do not use TEFLON ®tape. You will need to determine the fittings
required depending on your installation.
11
Complete Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
2.
3.
A. Closed valve
B. Open valve
Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles appear, a
leak is indicated. Correct any leak found.
Remove surface burner caps and grates from parts package.
Align notches in burner caps with pins in burner base. Burner
caps should be level when properly positioned. If burner caps
are not properly positioned, surface burners will not light.
Place burner grates over burners and caps.
A
A. Burner cap
B. Burner ports
C. Burner base
D. Gas tube opening
E. Igniter head
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
4. Plug into a grounded 3 prong outlet.
Initial lighting and gas flame adjustments
This cooktop is equipped for electronic auto-reignition by means
of a spark igniter located at the rear of each burner. The burners
are designed to light at any valve rotation that admits sufficient
gas flow to support a flame and to automatically relight following
a loss of flame due to a draft or other adverse condition. This
feature is provided only as a convenience.
Check Operation of Surface Burners
Push in and turn the surface burners control knobs to light.
The surface burner flame should light within 4 seconds. The first
time a surface burner is lit, it may take longer that 4 seconds to
light because of air in the gas line.
Check the flame on "HIGH" for a blue color. It should be clean
and soft in character. No yellow tip, blowing or lifting of flame
should occur. Occasional orange flashes are normal and reflect
different elements in the air or gas.
After verifying the proper burner operation, turn the control knobs
to "OFR"
If burners do not light properly:
Turn surface burner control knob to the "OFF" position.
Check that the power supply cord is plugged in and the
circuit breaker has not tripped or the fuse blown.
Check that the gas shutoff valves are set to the "open"
position.
Check that burner caps are properly positioned on burner
bases.
Recheck operation of surface burners. If a burner does not light
at this point, contact your dealer or authorized service company
for assistance.
Adjust Flame Height
Smart Port Burner System
This cooktop is equipped with a Smart Port Burner System. The
Smart Port Burner System produces a small flame directly under
each grate finger and a larger flame between each grate finger.
The visual difference between the ports will be noticeable when
the burner is used or when adjustments are made to the flame
length.
Adjust the height of top burner flames. The cooktop "low" burner
flame should be a steady blue flame approximately 1¼,,(0.64 cm)
high.
B
Lrd Lrd Lrd Lrd Lrd Lrd
A. Low flame
B. High flame
12
To adjust standard burners:
The flame can be adjusted using the adjustment screw in the
center of the valve stem. The valve stem is located directly
underneath the control knob.
If the "low" flame needs to be adjusted:
1. Light 1 burner and turn to lowest setting.
2. Remove the control knob.
3. Hold the knob stem in the low position using a pair of pliers.
Use an 1/8"(3.0 mm) flat-blade screwdriver to turn the screw
located in the center of the control knob stem until the flame
is the proper size.
1. Check that all parts are now installed. If there is an extra part,
go back through the steps to see which step was skipped.
2. Check that you have all your tools.
3. Dispose of/recycle all packaging materials.
4. Use a mild solution of liquid household cleaner and warm
water to clean cooktop before use. Dry thoroughly with a soft
cloth. For more information, see the "Cooktop Care" section
of the Use and Care Guide.
5. Read "Cooktop Use" in the cooktop Use and Care Guide.
6. Reconnect power.
NOTE: If the cooktop does not work after turning on the power,
check that a circuit breaker has not tripped or a household fuse
has not blown. See "Troubleshooting" section in the Use and
Care Guide for further information.
7. Use the Flow Tester Card provided with your cooktop to
check the airflow (see card for step-by-step instructions).
If you need Assistance or Service:
Please reference the "Assistance or Service" section of the Use
and Care Guide or contact the dealer from whom you purchased
your cooktop.
4. Replace the control knob.
5. Test the flame by turning the control from "LO" to "HI,"
checking the flame at each setting.
6. Repeat the above steps for each burner.
SECURITEDELATABLEDECUlSSON
Votre securite et celle des autres est tres importante.
Nous donnons de nombreux messages de s_curit_ importants dans ce manuel et sur votre appareil m_nager. Assurez-vous de
toujours lire tousles messages de s_curit_ et de vous y conformer.
Voici le symbole d'alerte de s_curit&
Ce symbole d'alerte de s_curit_ vous signale les dangers potentiels de d_c_s et de blessures graves &vous
et & d'autres.
Tousles messages de s_curit_ suivront le symbole d'alerte de s_curit_ et le mot "DANGER" ou
"AVERTISSEMENT". Ces mots signifient
Risque possible de d_ces ou de blessure grave si vous ne
suivez pas imm_diatement les instructions.
Risque possible de d_ces ou de blessure grave si vous
ne suivez pas les instructions.
Tousles messages de s_curit_ vous diront quel est le danger potentiel et vous disent comment r_duire le risque de blessure et
ce qui peut se produire en cas de non-respect des instructions.
13
AVERTISSEMENT Si les renseignements dans ce manuel ne sont pas exactement
observes, un incendie ou une explosion peut survenir, causant des dommages au
produit, des blessures ou un deces.
- Ne pas entreposer ni utiliser de I'essence ou d'autres vapeurs ou liquides inflammables
proximite de cet appareil ou de tout autre appareil electromenager.
-QUE FAIRE DANS LE CAS D'UNE ODEUR DE GAZ :
Ne pas tenter d'allumer un appareil.
Ne pas toucher a un commutateur electrique.
Ne pas utiliser le telephone se trouvant sur les lieux.
Appeler immediatement le fournisseur de gaz a partir du telephone d'un voisin. Suivre
ses instructions.
.&.defaut de joindre votre fournisseur de gaz, appeler les pompiers.
- L'installation et I'entretien doivent _tre effectues par un installateur qualifie, une agence
de service ou le fournisseur de gaz.
AVERTISSEMENT : L'odorat ne permet pas toujours la detection d'une fuite de gaz.
Les distributeurs de gaz recommandent I'emploi d'un detecteur de gaz (homologation UL ou CSA).
Pour d'autre information, contacter le fournisseur de gaz local.
En cas de detection d'une fuite de gaz, executer les instructions "Que faire dans le cas d'une odeur de gaz".
Dans 1'12tatdu Massachusetts, les instructions d'installation suivantes sont applicables :
Les travaux d'installation et r_paration doivent 6tre executes par un plombier ou tuyauteur qualifi_ ou licenci_, ou par le
personnel qualifi_ d'une entreprise licenci_e par 1'12tatdu Massachusetts.
Si une vanne & boisseau sph_rique est utilis_e, elle doit comporter une manette "T".
Si un conduit de raccordement flexible est utilis_, sa Iongueur ne doit pas d_passer 3 pi.
EXIGENCESD'INSTALLATION
Rassembler les outils et pieces necessaires avant d'entreprendre
I'installation. Lire et suivre les instructions fournies avec chacun
des outils de la liste ci-dessous.
Outils n_cessaires
Metre-ruban Foret de 1¼,,
Tournevis a lame plate Scie sauteuse
Pi_ces fournies
Grille de ventilation
Pre-filtre
Trousse de conversion
pour I'alimentation au
propane
Chapeaux de brQleur
Grilles de brQleur
Detendeur
Tournevis cruciforme
Perceuse
Niveau
Marqueur ou crayon
Cle & cliquet avec douille de
3/8';
Compose d'etancheite des
raccords filetes - resistant
au gaz propane
Pi_ces n_cessaires
Conduits metalliques
Brides de conduit
Bouche de decharge murale
Pince Solution non corrosive de
detection des fuites
Clapet de bouche de decharge murale a surface arrondie de
6" (15,2 cm)
Commander la piece numero A406
14
Clapet de bouche de decharge murale a surface arrondie de
5" (12,7 cm)
Commander la piece numero A405
Clapet de bouche de decharge murale a surface arrondie de
31¼"x 10" (8,3 x 25,4 cm)
Commander la piece numero A403
Pour commander, voir la section "Assistance ou service" du
Guide d'utilisation et d'entretien.
Verifier les codes Iocaux et consulter le fournisseur de gaz.
Verifier I'alimentation en gaz et I'alimentation electrique
existantes. Voir les sections "Specifications electriques" et
"Specifications de I'alimentation en gaz".
II est recommande de faire realiser tousles raccordements
electriques par un electricien qualifie agre6.
IMPORTANT : Observer les dispositions de tousles codes et
reglements en vigueur. Lors de I'installation de la table de
cuisson, utiliser les dimensions minimums indiquees.
C'est & I'installateur qu'incombe la responsabilite de
respecter les distances de separation exigees, specifiees sur
la plaque signaletique de I'appareil. La plaque signaletique se
trouve sur le c6te de la chambre de distribution &aspiration
par le bas.
Afin de supprimer le risque de brQlures ou d'incendie en se
penchant au-dessus des unites de surface chauffees, le
rangement en armoire au-dessus des unites de surface doit
_tre evite. Si des placards de rangement sont envisages, le
risque peut _tre reduit par I'installation d'une hotte de cuisine
depassant le bas des placards d'au moins 5" (12,7 cm)
horizontalement.
La table de cuisson doit _tre installee dans un emplacement &
I'ecart des zones de forts courants d'air, telles que fen_tres,
portes et events ou ventilateurs de chauffage.
Toutes les ouvertures dans lemur ou le plancher de
I'emplacement d'installation de la table de cuisson doivent
_tre scellees.
Respecter les dimensions indiquees pour les ouvertures
decouper dans les placards. Ces dimensions constituent les
valeurs minimales des degagements.
Une source d'electricite avec liaison & la terre est necessaire.
Voir la section "Specifications electriques". Un raccordement
adequat a I'alimentation en gaz doit _tre disponible. Voir la
section "Specifications de I'alimentation en gaz".
De par sa conception, la table de cuisson est suspendue au
plan de travail, par les rebords des c6tes ou de I'arriere.
Veiller & placer les sources de gaz et d'electricite selon les
indications de la section "Dimensions du placard" pour
qu'elles soient accessibles sans avoir a retirer la table de
cuisson.
Prevoir une ouverture dans I'angle arriere droit de I'enceinte-
voir I'illustration - pour le passage de la canalisation de gaz et
du c&ble d'alimentation electrique et pour que I'etiquette
signaletique soit visible.
Si le placard comporte des tiroirs, ces tiroirs doivent _tre
retires et I'avant des tiroirs installe sur I'avant du placard.
IMPORTANT : II n'est pas possible d'installer un four encastre
sous plan de travail sous ce produit.
IMPORTANT : Afin d'eviter d'endommager les placards,
consulter le constructeur de la maison ou le fabricant des
placards pour determiner si les materiaux utilises peuvent subir
un changement de couleur, une destratification ou d'autres
dommages.
R_sidence mobile - Sp6cifications additionnelles
respecter Iors de I'installation
L'installation de cette table de cuisson doit _tre conforme aux
dispositions de la norme Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280 (anciennement Federal
Standard for Mobile Home Construction and Safety, Title 24,
HUD Part 280). Lorsque cette norme n'est pas applicable, utiliser
la norme Standard for Manufactured Home Installations, ANSI
A225.1/NFPA 501A ou respecter les dispositions des codes
Iocaux.
Au Canada, I'installation de cette table de cuisson doit
satisfaire aux stipulations de la version la plus recente de la
norme CAN/CSA-A240 ou des codes Iocaux en vigueur.
Dimensions du produit
Table de cuisson de 30" (76,2 cm)
A
/
A. 21 _4" (54,8 cm) avec garniture en acier
inoxydable ou 21V2" (54,6 cm) sans garniture
en acier inoxydable
B. 194z_4'' (50,1 cm) d'une t_te de vis _ I'autre
C. Emplacement/d_gagement du modele/de la
plaque signal6tique
A. 291_,, (76,1 cm) sans
garniture en acier inoxydable
B. 30 _2" (76,3 cm) sans
garniture en acier inoxydable
C. 122_j ' (31,6 cm) entre I'axe
central de la table de cuisson
et I'axe central de la tubulure
de distribution de gaz
D. 7_" (18,6 cm)
E.3 _4" (9,2 cm)
F. 15" (38,1 cm)
G. 25_2'' (5,5 cm) de d_gagement
minimum recommand_ entre
la caisse et le moteur
H. 1411_2"(36,4 cm)
I. 114_4" (29,9 cm)
J. 28_" (72,1 cm) d'une t_te de
vis _ I'autre
15
Dimensions du placard Dimensions de I'ouverture _ d_couper
G
A. 30" (76,2 cm)
B.Zone de matiere combustible au-dessus du plan de travail (espace
d_limit_ par des lignes pointill_es ci-dessus)
C. Distance minimale de s_paration de 30" (76,2 cm) entre le dessus de
la table de cuisson et le fond d'un placard m_tallique ou de bois non
couvert (distance de s#paration de 24" [61 cm] ou plus si le fond du
placard de m_tal ou de bois est recouvert d'une plaque d'au moins
¼" (0,6 cm) de mat_riau r_sistant aux flammes, lui-m_me recouvert
d'une feuille m_tallique d'une _paisseur correspondant _ un calibre
de 28 au moins pour I'acier, 0,015" [0,04 cm] pour I'acier inoxydable,
0,024" [0,06 cm] pour I'aluminium ou 0,020" [0,05 cm] pour le
cuivre)
D. Profondeur recommand_e pour les placards sup_rieurs : 13" (33 cm)
E. 2_" (5,4 cm)
F. 191_,, (50,6 cm)
G. Distance de s_paration minimale de 18" (45, 7cm) entre le placard
sup_rieur et le plan de travail avec distance minimale de s_paration
horizontale pour la table de cuisson
H. Boftier de connexion ou prise _lectrique; 12" (30,5 cm) ou plus
depuis le bas du plan de travail
I. Boftier de connexion ou prise _lectrique; 10" (25,4 cm) depuis le
c6t_ droit du placard
J. 28 _" (72, 7cm) sur les modeles de 30" (76,2 cm)
K. Distance de s_paration minimale de 8" (20,3 cm) par rapport _ la
surface de mat_riau combustible la plus proche, _ gauche ou
droite au-dessus de la table de cuisson
L. Distance de s_paration minimale de 2" (5,1 cm) ou plus entre la
paroi arriere et le plan de travail
M. Ouverture pour canalisation de gaz - mur : n'importe oh, _ 6"
(15,2 cm) au-dessous de la face inf_rieure du plan de travail, du c6t_
gauche. Plancher du placard : n'importe oO, _ 6" (15,2 cm) de la
paroi arriere et du c6t_ gauche - recommand&
N. Profondeur de la table de cuisson 25" (63,5 cm)
REMARQUES Apres le decoupage de I'ouverture dans le plan
de travail, il est possible que pour certaines configurations
d'installation, il soit necessaire d'entailler les parois laterales du
placard inferieur pour permettre le passage de la base de la table
de cuisson. Pour eviter cette modification, utiliser un placard
inferieur dont la largeur des parois laterales est superieure & celle
de I'ouverture decoup6e.
Un degagement minimum de 6" (15,2 cm) entre le c6te de la
table de cuisson et la paroi laterale est recommande pour une
performance maximale de ventilation.
Un degagement minimum de 2" (5,1 cm) entre le moteur/
ventilateur et le placard est recommande pour que le
refroidissement puisse s'effectuer correctement. Un
degagement de 6" (15.2 cm) est recommande pour pouvoir
acceder en cas de reparations.
H //
A. 28_" (72, 7 cm) maximum
B. 191_,, (50,6 cm) maximum
C. 95_ '' (21,6 cm)
D. 64_4 '' (17,2 cm)
E.D_gagement minimal de 2 _" (5,4 cm) jusqu'au rebord avant de la
table de cuisson
F. Option d'_vacuation par le plancher
G. 6_" (15,6 cm) pour systeme d'_vacuation de 6" (15,2 cm) et
5 _" (13,1 cm) pour systeme d'_vacuation de 5" (12, 7 cm)
H. 95_ '' (21,6 cm)
I. 13_" (33,9 cm) _ partir du dessus de la surface de plan de travail
J. Option d'_vacuation par lemur
IMPORTANT : L'evacuation de cette table de cuisson doit se
faJre vers I'exterieur.
Ne pas terminer le circuit d'evacuation dans un grenier ou
dans un autre espace clos.
Utiliser un clapet de conduit.
Le circuit doit evacuer I'air a I'exterieur.
Utiliser uniquement un clapet de 6" (15,2 cm) de diametre ou
un clapet rectangulaire de 3 W' x 10" (8,3 x 25,4 cm), sauf
dans le cas suivant : Pour les modeles a gaz, on doit utiliser
un clapet de 5" (12,7 cm) de diam_tre si la Iongueur des
conduits est de 10 pi (3 m) ou moins.
Avant d'effectuer des decoupes, s'assurer que I'espace est
suffisant sur lemur ou le plancher pour le conduit
d'evacuation.
On ne doit couper un poteau de colombage ou une solive
que si c'est absolument necessaire. Dans ce cas, on devra
construire une structure de support appropriee.
La taille du conduit doit _tre uniforme.
Le circuit d'evacuation doit comporter un clapet anti-reflux. Si
la bouche de decharge murale ou par le toit comporte un
clapet, ne pas utiliser le clapet fourni avec la hotte de
cuisiniere.
Pour assurer I'etancheite de toutes les jonctions du circuit
d'evacuation, utiliser des brides pour conduit.
/_,I'aide d'un produit de calfeutrage, assurer I'etancheite
autour de la bouche de decharge a I'exterieur (&travers le
mur ou le toit).
Determiner la methode d'evacuation la plus appropriee.
16
Pour une performance optimale :
Utiliser un conduit metallique en acier galvanise de calibre
26 minimum ou en aluminium de calibre 25 minimum. Des
raccords de tube de qualite mediocre peuvent reduire la
circulation d'air. On deconseille I'emploi d'un conduit en
metal flexible.
REMARQUE : Los codes Iocaux peuvent imposer un
materiau d'epaisseur superieure.
Los conduits metalliques peuvent _tre reduits &de I'acier
galvanise de calibre 30 ou de I'acier aluminise de calibre 26 si
los codes Iocaux I'autorisent. Cette reduction repose sur los
informations du document International Residential Codes
Section M1601.1 (edition 2006).
Ne pas installer 2 coudes successifs.
Ne pas utiliser plus de trois coudes a 90°.
Si un coude est utilise, on doit le placer le plus loin possible
de I'ouverture de decharge du ventilateur de la hotte.
Veiller & incorporer une section de conduit rectiligne d'au
moins 18" (45,7 cm) entre deux raccords coudes adjacents.
Des coudes trop rapproches peuvent occasionner une
turbulence excessive qui reduit la circulation de I'air.
Ne pas utiliser de coude de 5" (12,7 cm) dans un circuit de
6" (15,2 cm) ou 31/4"x 10" (8,3 x 25,4 cm)
Ne pas effectuer de reduction vers un circuit de 5" (12,7 cm)
apres avoir utilise des raccords de 6" (15,2 cm) ou 31/4"x
10" (8,3 x 25,4 cm).
12viterlos assemblages par sertissage & la main. Los
sertissages a la main peuvent reduire la circulation d'air.
Utiliser los clapets muraux decrits dans la section "Outillage
et pieces" pour une performance optimale. Si une bouche de
decharge de toit ou murale est utilisee, s'assurer que sos
dimensions ne sont pas plus petites et qu'elle est equipee
d'un clapet anti-retour.
Pour assurer I'etancheite de toutes los jonctions du circuit
d'evacuation, utiliser des brides pour conduit.
A I'aide d'un produit de calfeutrage, assurer I'etancheite
autour de la bouche de decharge a I'exterieur (& travers le
mur ou le toit).
La Iongueur du systeme d'evacuation et le nombre de coudes
doit _tre reduit au minimum pour des performances optimales.
La Iongueur equivalente maximale du circuit d'evacuation est de
60 pi (18,3 m). A une altitude superieure a 4500 pi (1272 m),
reduire la Iongueur du circuit d'evacuation de 20 % pour une
meilleure performance.
Installations dans los r_gions au climat froid
On devrait installer un clapet anti-retour supplementaire pour
minimiser le reflux d'air froid et une barriere thermique pour
minimiser la conduction des temperatures exterieures par
I'intermediaire du circuit d'evacuation. Le clapet anti-retour _tre
place du c6te air froid de la barriere thermique.
Air d'appoint
Los codes Iocaux en b&timent peuvent imposer I'emploi d'un
circuit de renouvellement de I'air/introduction d'air d'appoint, Iors
de I'utilisation d'un circuit d'aspiration de debit superieur & une
valour specifiee en pieds cubes par minute. Le debit specific en
pieds cubes par minute varie d'une juridiction & I'autre. Consulter
un professionnel des installations de chauffage ventilation/
climatisation au sujet des exigences specifiques applicables
dans la juridiction locale.
Los methodes d'evacuation standard illustrees correspondent &
une table de cuisson avec aspiration par le bas montee sur
comptoir. L'evacuation de la table de cuisson pout se faire par le
mur ou le plancher.
Option 1 - D_charge a Option 2 - D_charge
travers le toit travers le tour
A
A. Bouche de d_charge sur toit
B. Conduit de dia. 6" (15,2 cm) -
sortie _ travers le toit
Option 3 - I_vacuation entre
los solives au plancher
\
A. Bouche de d_charge murale
B. Conduit de dia. 6" (15,2 cm)
pour sortie _ travers lemur
A. Conduit de dia. 6" (15,2 cm)
pour sortie _ travers lemur
B. Bouche de d_charge murale
Option 4 - I_vacuation
derriere le garde-pieds de
la caisse
== ==
A. Bouche de d_charge murale
B. Conduit de dia. 6" (15,2 cm)
pour sortie _ travers lemur
17
Installations sur dalle de b_ton -
Evacuation par un puits de fen_tre
B
A .........
M
L
A. Bouche de d_charge murale
B. 12" (30,5 cm) minimum
C. Dalle de b_ton
D. Conduit PVC dia. 6" (15,2 cm) (pour _gout)
E. Raccord de transition de 5" _ 6" (12,7 cm _ 15,2 cm)
F. Conduit m_tallique de dia. 6" (15,2 cm)
G. Raccord PVC de dia. 6" (15,2 cm)
H. Conduit PVC pour _gout de dia. 6" (15,2 cm)
I. Coude _ 90 °en PVC pour _gout de dia. 6" (15,2 cm)
J. Gravier ou sable compact_ tout autour du tuyau.
K. 42 pi (12,8 m) max.
L. Raccord PVC de dia. 6" (15,2 cm)
M. 6" (15,2 cm) minimum
N. Puits de fen_tre
Installations sur dalle de b_ton - I_vacuation par le mur
B
M
/ .............................
0
E
c i¸ ...............................G
_ ' !_ :_ ............../
,------- L -------_1 ......................
K
A. Bouche de d_charge murale
B. Conduit m_tallique rond de dia. 6" (15,2 cm)
C. 16" (40,6 cm) maximum
D. Conduit PVC dia. 6" (15,2 cm) (pour _gout)
E. Raccord de transition de 5" _ 6" (12,7 cm _ 15,2 cm)
F. Conduit m_tallique de dia. 6" (15,2 cm)
G. Raccord PVC de dia. 6" (15,2 cm)
H. Dalle de b_ton
I. Conduit pour _gout en PVC de dia. 6" (15,2 cm)
J. Raccord coud_ 90° PVC dia. 6" (15,2 cm) (pour _gout)
K. Gravier ou sable compact_ tout autour du tuyau.
L. 30 pi (9,1 m) max.
M. Raccord coud_ pour _gout de 90 ° en PVC de dia.
6" (15,2 cm)
N. Raccord PVC de dia. 6" (15,2 cm)
O. 12" (30,5 cm) minimum
Calcul de la Iongueur effective du circuit d'_vacuation
Pour calculer la Iongueur effective du circuit d'evacuation
necessaire, additionner les Iongueurs equivalentes (en pieds ou
m_tres) de tousles composants utilises dans le systeme.
Composant Conduit de diam_tre de 6"
(15,2 cm)
Coude a 45 ° 2,5 pi _
(0,8 m)
LJ
Coude a 90 ° 5 pi
(1,5 rn)
Decharge murale de 6" 0 pi
(15,2cm) (0,0 m)
Raccord de 3V4" x 10" (8,3 cm 4,5 pi
x 25,4 cm) sur 6" (15,2 cm) (1,4 m)
Raccord de 6" (15,2 cm) sur 1 pi
3V4" x 10" (8,3 cm x 25,4 cm) (0,3 m)
Raccord coude 90° de 3V4" x 9 pi
10" (8,3 cm x 25,4 cm) (2,7 m)
sur 6" (15,2 cm)
Raccord coude &90° de 6" 5 pi
(15,2 cm) vers 3V4" x 10" (1,5 m)
(8,3 cm x 25,4 cm)
Coude & 90 ° de 3V4" x 10" 5 pi
(8,3 cm x 25,4 cm) (1,5 m)
Coude plat de 3V4" x 10" 12 pi
(8,3 cm x 25,4 cm) (3,7 m)
Decharge murale de 3V4" x 10" 0 pi
(8,3 cm x 25,4 cm) (0,0 m)
Raccord de transition de 5" sur 1 pi
6" (12,7 cm & 15,2 cm) (0,3 m)
18
Exemple de circuit d'_vacuation
bouche de d_chargernurale
coude _ 90 ° , \
6 pi (1,8 rn)
U
1 coude & 90° = 5 pi (1,5 m)
Section droite de 8 pi = 8 pi (2,4 m)
(2,4 m)
1 bouche de decharge = 0 pi (0 m)
murale
Longueur totale = 13 pi (3,9 m)
REMARQUE : On deconseille I'emploi d'un conduit flexible. Un
conduit flexible peut causer une contre-pression et des
turbulences d'air, qui reduisent considerablement la
performance.
D_terminer le r_glage du ventilateur de la cuisini_re
Cette table de cuisson est equip6e d'un ventilateur & deux debits.
Sa configuration d'usine correspond & une aspiration faible pour
pouvoir convenir a la plupart des installations. Si la Iongueur
equivalente de conduit depasse 30 pi (9,1 m), le ventilateur doit
etre converti au mode &forte aspiration. Ne pas convertir le
ventilateur au mode & forte aspiration pour des Iongueurs
inferieures; ceci entrafnerait un niveau sonore excessif et une
perte d'air conditionn& Convertir le ventilateur avant de I'installer
dans le plan de travail si necessaire.
Conversion au mode & forte aspiration :
1. Placer la table de cuisson sur le plancher avec la rive avant et
le plenum orientes vers le bas.
2. Retirer les quatre contre-ecrous n° 10 - 32 (A)fixant le moteur
du ventilateur a la volute d'evacuation du ventilateur.
3. Retirer le moteur du ventilateur (B) de la volute d'evacuation
du ventilateur (E).
4. Passer lentement le bras dans I'ouverture de la volute
d'evacuation du ventilateur et retirer I'attache (C).
5. Retirer I'anneau de serrage avec precaution (D).
6. Reinstaller le moteur sur les pitons de la volute d'evacuation
du ventilateur.
7. Reinstaller les quatre contre-ecrous n° 10-32 pour fixer le
moteur du ventilateur a la volute d'evacuation du ventilateur.
/
)
i
AB CD EF
A. Contre-_crou n°lO - 32
B. Ensemble moteur de ventilateur et roue
C. Attache
D. Anneau de serrage
E. Volute d'_vacuation
F. Protection de la roue du ventilateur
IMPORTANT La table de cuisson doit etre correctement reliee
la terre en conformite avec les codes et r_glements Iocaux en
vigueur, ou en I'absence de tels codes, avec le National Electrical
Code, ANSl/NFPA 70 ou le Code canadien des installations
electriques, CSA C22.1.
Cette table de cuisson est dotee d'un systeme d'allumage
electronique qui ne fonctionnera pas en cas de branchement
dans une prise qui n'est pas correctement polarisee.
Si les codes le permettent et si on utilise un conducteur distinct
de liaison a la terre, il est recommande qu'un electricien qualifie
verifie la qualite de la liaison & la terre.
Pour obtenir un exemplaire de la norme des codes ci-dessus,
contacter :
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
L'appareil doit etre alimente par un circuit de 120 V, CA
seulement, 60 Hz, 15 amperes, protege par fusible. On
recommande egalement d'utiliser un fusible ou un disjoncteur
temporis& II est recommande de raccorder la table de
cuisson sur un circuit distinct exclusif &cet appareil.
Les systemes d'allumage electronique fonctionnent avec des
limites de tension etendues, mais une liaison &la terre
correcte et une polarite appropriee sont necessaires. Verifier
que la prise fournit une alimentation de 120 Vet qu'elle est
correctement reliee a la terre.
Les schemas de c&blage sont fournis avec cette table de
cuisson. Voir la section "Schemas de c&blage" sur une feuille
separee. Les schemas de c&blage se trouvent sur la partie
inferieure de la bas de la table de cuisson, du c6te gauche.
19
SDd c t ccI ons de ct m® 's st on ®n gc z
Risque d'expJosion
Utiliser une canalisation neuve d'arriv_e de gaz
approuv_e par la CSA International.
installer un robinet d'arr_t.
Bien sorter chaque organe de connexion de la
canalisation de gaz.
En cas de connexion au gaz propane, demander a une
personne quaJifi_e de s'assurer que la pression de gaz
ne d_passe pas 36 cm (14 po) de la colonne d'eau.
Par personne quaJJfi_e, on comprend :
le personnel autoris_ de chauffage,
le personnel autoris_ d'une compagnie de gaz, et
le personnel d'entretien autoris&
Le non=respect de cos instructions pout causer
un d_c_s, une explosion ou un incendie.
Observer les dispositions de tousles codes et reglements en
vigueur.
IMPORTANT L' installation doit satisfaire aux criteres de tousles
codes et reglements Iocaux. En I'absence de code local,
I'installation doit satisfaire aux prescriptions de la plus recente
edition du code national americain en vigueur : National Fuel Gas
Code ANSI Z223.1 ou & la norme CAN/CGA B149.
IMPORTANT Les tests de fuite de la table de cuisson doivent
_tre effectues selon les instructions du fabricant.
Type de gaz
Gaz naturel :
La conception de cette table de cuisson a ete homologuee par
CSA International pour I'alimentation au gaz naturel, ou pour
I'alimentation au propane apres conversion adequate.
Cette table de cuisson a ete configuree a I'usine pour
I'alimentation au gaz naturel. Pour la conversion pour
I'alimentation au propane, les instructions "Conversion pour
I'alimentation au propane" dans le sachet de documentation.
La plaque signaletique des numeros de modele et de serie
situee sur la face inferieure de la base de la table de cuisson
indique les types de gaz utilisables. Sile type de gaz
disponible n'est pas mentionne sur la plaque signaletique,
consulter le fournisseur de gaz local.
Conversion pour I'alimentation au propane :
L'operation de conversion doit _tre executee par un technicien
de reparation qualifi&
Ne pas entreprendre de convertir la table de cuisson pour
I'utilisation d'un gaz different de celui indique sur la plaque
signaletique sans d'abord consulter le fournisseur de gaz. Voir les
instructions de conversion de gaz fournies dans le sachet de
documentation.
Canalisation de gaz
Installer une canalisation de gaz rigide de 34"(1,9 cm) jusqu'&
I'emplacement d'installation de la table de cuisson. L'emploi
d'une canalisation de plus petit diametre sur un circuit plus
long peut causer une deficience du debit d'alimentation. On
doit utiliser un compose d'etancheite des tuyauteries
resistant a I'action du gaz de petrole liquefi& Ne pas utiliser
de ruban TEFLON% Pour I'alimentation au propane, le
diametre du tuyau ou conduit doit _tre de 1/2"ou plus.
Usuellement, le fournisseur de gaz propane determine les
materiaux & utiliser et le diametre appropri&
Raccord m_tallique flexible :
Si les codes Iocaux le permettent, utiliser un connecteur
gaz flexible en acier inoxydable de 1/2"ou %" de diametre
interne, con_;u par CSA pour raccorder la table de
cuisson & la canalisation rigide d'alimentation en gaz.
Un raccord avec filetage m&le de 1/2"est necessaire pour
la connexion sur le raccord & filetage femelle & I'entree du
detendeur de la table de cuisson.
Ne pas deformer/ecraser/endommager letube metallique
flexible Iors d'un deplacement de la table de cuisson.
Raccordement par un ensemble rigide :
On doit utiliser une combinaison de raccords pour realiser un
raccordement rigide entre la table de cuisson et la
canalisation de gaz. Le tuyau rigide doit se trouver au m_me
niveau que le raccord de connexion de la table de cuisson.
On doit veiller & ne soumettre les sections de canalisation
d'alimentation et de combustible &aucun effort de traction ou
flexion pour que la table de cuisson soit d'aplomb et
correctement alignee.
Robinet d'arr_t necessaire :
La canalisation d'alimentation doit comporter un robinet
d'arr_t manuel. Le robinet d'arr_t manuel doit _tre separe de
la table de cuisson, mais doit se trouver dans la m_me piece,
comme par exemple un placard adjacent. IIdoit se trouver en
un endroit facilement accessible et qui ne necessite pas le
demontage de la table de cuisson pour les manceuvres
d'ouverture/fermeture. Ne pas entraver I'acces au robinet
d'arr_t manuel. Le robinet d'arr_t manuel est prevu pour
ouvrir ou fermer I'alimentation en gaz de la table de cuisson.
B
A. Canalisation de gaz
B. Robinet d'arr_t - position d'ouverture
C. Vers la table de cuisson
1-®TEFLON est une marque d6pos&e de E.I. Du Pont De Nemours et Compagnie
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

KitchenAid KGCD807XBL01 Guide d'installation

Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues