Whirlpool YGH8155XMQ1 Guide d'installation

Taper
Guide d'installation
MICROWAVE HOOD COMBINATION
INSTALLATION INSTRUCTIONS
This product is suitable for use above electric or gas cooking products up to 36" (91.4 cm) wide.
These installation instructions cover different models. The appearance of your particular model may differ slightly from the
illustration in these installation instructions.
NOTES:
Proper installation isthe responsibility of the installer.
Product failure due to improper installation is not coveredunder the warranty.
INSTRUCTIONSD'INSTALLATION
DEL'ENSEMBLEFOUR MICRO-ONDES/HOTTE
Ce produit est congu pour I'utilisation au-dessus d'appareils de cuisson 61ectriques ou _.gaz de 36" (91,4 cm) de largeur
ou moins.
Ces instructions d'installation sent valables pour plusieurs mod_les. IIse peut que I'apparence de votre propre mod_le soit
16g_rement diff6rente de celle montr6e sur les illustrations dans ce document.
REMARQUES :
C'est &I'installateur qu'il incombe de realiserune installation correcte.
Lesdefaillances du produit dues &une installation incorrecte nesent pas couvertes par la garantie.
Table of Contents / Table des mati@res
MICROWAVE HOOD COMBINATION SAFETY ......................... 2
VENTING DESIGN SPECIFICATIONS ......................................... 2
INSTALLATION REQUIREMENTS .............................................. 3
Tools and Parts .......................................................................... 3
Location Requirements .............................................................. 4
Product Dimensions ................................................................... 4
Electrical Requirements ............................................................. 5
INSTALLATION INSTRUCTIONS ................................................ 5
Remove Mounting Plate ............................................................ 5
Rotate Air Deflector .................................................................... 5
Locate Wall Stud(s) .................................................................... 7
Mark Rear Wall ........................................................................... 8
Drill Holes in Rear Wall ............................................................... 8
Attach Mounting Plate to Wall ................................................... 9
Prepare Upper Cabinet .............................................................. 9
Install Damper Assembly ........................................................ 10
Installthe Microwave Oven ..................................................... 10
Complete installation .............................................................. t 2
ASSISTANCE .............................................................................. 12
Replacement Parts .................................................................. t 2
Accessories ............................................................................. 12
SleCURITle DE L'ENSEMBLE FOUR .&MICRO-ONDES/HOTTE....13
SPleCIFICATIONS/CONCEPTION DU CIRCUIT D'IeVACUATION .13
EXIGENCES D'INSTALLATION ......................................................... 15
Outillage et pieces ........................................................................... t 5
Exigenees d'emplacement .............................................................. 15
Dimensions du produit ..................................................................... t6
Specifications _lectriques ................................................................ t6
INSTRUCTIONS D'INSTALLATION ................................................... 17
D_pose de la plaque de montage ................................................... 17
R_orientation du d_flecteur d'air ..................................................... 17
Identifier la position du/des poteaux du colombage mural ............ 19
Trac_ sur lemur arriere .................................................................... 20
Percage de trous dans lemur arri_re .............................................. 20
Fixation de la plaque de montage sur le mur .................................. 21
Preparation du placard mural .......................................................... 22
Installation du module du clapet anti-reflux .................................... 22
Installation du four & micro-ondes ................................................... 22
Achever I'installation ........................................................................ 24
ASSISTAN CE ...................................................................................... 24
Pieces de rechange ......................................................................... 24
Accessoires ...................................................................................... 24
IMPORTANT: Read Installation Instructions thoroughly before beginning installation. Save Installation Instructions for local house
inspector's use.
IMPORTANT : Lire completement les instructions d'installation avant de commencer I'installation. Conserver ces instructions
d'installation & I'usage de I'inspecteur local des installations de la maison.
8206197
MICROWAVE HOOD COMBINATION SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
VENTING DESIGN SPECIFICATIONS
This section is intended for architectural designer and builder/contractor reference only.
NOTES:
Vent materials needed for installation are not provided with
microwave hood.
We do not recommend using a flexible metal vent.
Toavoid possible product damage, be sure to vent air outside,
unless using ventless (recirculating) installation. Do not vent
exhaust air into concealed spaces, such as spaces within
walls or ceilings, attics, crawl spaces or garages.
For optimal venting installation, we recommend:
using roof or wall caps that have back draft dampers
using a rigid metal vent
using the most direct route by minimizing the length of the
vent and number of elbows to provide efficient performance
using uniformly sized vents
using duct tape to seal all joints in the vent system
using caulking compound to seal exterior wall or roof opening
around cap
not installing 2 elbows together, for optimal hood performance
If venting through the wall, be sure that there is proper clearance
within the wall for the damper to open fully.
If venting through the roof, and rectangular to round transition is
used, be sure there is at least 3" (7.6 cm) of clearance between
the top of the microwave oven and the transition piece. See
"Rectangular to Round Transition" illustration.
Roof venting Roof cap
Wall venting Wall cap
Rectangular to Round Transition
NOTE: The minimum 3" (7.6 cm) clearance must exist between
the top of the microwave oven and the rectangular to round
transition piece so that the damper can open freely and fully.
B
C
3" (7.6 cm)
t
E
F
A. Roof cap
B. 6" (15.2 cm) min. diameter round vent
C. Elbow (for wall venting only)
D. Wall cap
E. 3¼" x 10" to 6" (8.3 x 25.4 cm to 15.2 cm)
rectangular to round transition piece
F Vent extension piece, at least 3" (7.6 cm) high
Recommended Standard Fittings
The following length equivalents are for use when figuring vent
length. See the examples in "Recommended Vent Length."
A B C
E F G
A. Rectangular to round transition piece: 3¼" x 10" to 6" = 5 ft
(8.3 x 25.4 cm to !5.2 cm = 1.5 m)
B. Roof cap: 3 ¼" x 10" = 24 ft (8.3 x 25.4 cm = 7.3 m)
C. 90° elbow: 3¼" x 10" =25 ft (8.3 x 25.4 cm = 7.6 m)
D. 90 ° elbow: 6" = !0 ft (15.2 cm = 3 m)
E. Wall cap: 3¼" x 10" = 40 ft (8.3 x 25.4 cm = 12.2 m)
F. 45 ° elbow: 6" = 5 ft (15.2 cm = 1.5 m)
G. 90 ° flat elbow: 3¼" x 10" = 10 ft (8.3 x 25.4 cm = 3 m)
Recommended Vent Length
A 3W' x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent
should be used.
The total length of the vent system including straight vent,
elbow(s), transitions and wall or roof caps must not exceed the
equivalent of 140 ft (42.7 m) for either type of vent. See
"Recommended Standard Fittings" section for equivalent lengths.
For best performance, use no more than three 90° elbows.
Tocalculate the length of the system you need, add the equivalent
lengths of each vent piece used in the system. See the following
examples:
3W' x 10" (8.3 x 25.4 cm) vent system = 73ft (22.2 m) total
A B
i_( 6ft (1.8 m) _
2 ft TI I
(0.6m)
C
A. One 3 ¼" x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m)
B. 1wall cap = 40 ft (12.2 m)
C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
6" (15.2 cm) vent system = 73 ft (22.2 m) total
A
I,_ 6 ft (1.8 rn)
................................................................................
B
C D
A. Two 90° elbows = 20 ft (6.1 m)
B. 1 wall cap = 40 ft (12.2 m)
C. 1rectangular to round transition piece = 5 ft (1.5 m)
D. 2 ft (O.6m) + 6 ft (1.8 m) straight = S ft (2.4 m)
Ifthe existing vent is round, a rectangular to round transition piece
must be used. In addition, a rectangular 3" (7.6 cm) extension vent
between the damper assembly and rectangular to round transition
piece must be installed to keep the damper from sticking.
INSTALLATION
REQUIREMENTS
Tools Needed
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Measuring tape
Pencil
Masking tape or thumbtacks
Scissors
No. 2 Phillips screwdriver
No. 3 Phillips screwdriver for
1/4-20 x 3" round-head bolts
Electric drill
3/16" (5 mm), 3/8" (10 mm)
drill bits
3/4" (19 mm) hole saw
Stud finder
7116" socket wrench
(or box wrench) for 1/4" x 2"
lag screws
1W' (3.8 cm) diam. hole drill
bit for wood or metal
cabinet
Keyhole saw
Caulking gun and
weatherproof caulking
compound
Duct tape
PartsSupplied
Forreorderinformation,see"ReplacementParts"section.
NOTE:Thehardwareitemslistedhereareforwoodstuds.For
othertypesofwallstructures,besuretouseappropriate
fasteners.
A. 1/4-20 x 3" bolts (6)
B. Washers (2)
C. Toggle nuts (4)
D. 1/4" x 2" lag screws (4)
E. Power supply cord bushing (!)
F Damperassembly (for wall or roof
venting)
Not Shown:
Upper cabinet template
Mounting plate (attached to
back of microwave oven)
Aluminum grease filters
Charcoal filters (Depending
on model, charcoal filters
may not be included. See
Use and Care Guide.)
NOTE: Depending on model, aluminum grease filter and charcoal
filter may be combined.
Materials needed
Standard fittings for wall or roof venting. See "Venting Design
Specifications" section.
Check the opening where the microwave oven will be installed.
The location must provide:
Minimum installation dimensions. See "Installation
Dimensions" illustration.
Minimum one 2" x 4" (50.8 x 101.6 mm) wood wall stud and
minimum 3/8" (9.5 mm) thickness drywall or plaster/lath within
cabinet opening.
Support for weight of 150 Ibs (68 kg), which includes
microwave oven and items placed inside the microwave oven
and upper cabinet.
Grounded electrical outlet inside upper cabinet. See
"Electrical Requirements" section.
NOTES:
If installing the microwave oven near a left sidewall, make sure *_
there is at least 6" (15.2 cm) of clearance between the wall and
/
the microwave oven, so that the door can open fully.
Some cabinet and building materials are not designed to 16w'
withstand the heat produced by the microwave oven for (41.3cm)
cooking. Check with your builder or cabinet supplier to make |
sure that the materials used will not discolor, delaminate or
l
sustain other damages.
Special Requirements
For Wall Venting Installation Only:
The 12" x 4" (30.5 x 10.2 cm) cutout area must align with the
rectangular hole in the mounting plate.
Cutout must be free of any obstructions so that the vent tube
fits properly, and the damper blade opens freely and fully.
For Roof Venting Installation Only:
If using rectangular to round transition piece, the 3" (7.6 cm)
clearance needs to exist above the microwave oven so that
the damper blade can open freely and fully. See "Rectangular
to Round Transition" illustration in "Venting Design
Specifications" section.
Installation Dimensions
NOTE: The grounded 3 prong outlet must be inside the upper
cabinet. See "Electrical Requirements" section.
A B
66" (167.6 cm) rain.
u ...........
30" (76.2 cm) typ!cal*
_ 12" (36.5 cm) rain.
14" (35.6 cm) max.
-_@_ .....
__ : ::::;: r:z:: ::: :
A.2" x 4" wallstud
B. Grounded3 prong outlet
*30" (76.2 cm) is typical for 66" (167.6 cm) installation height.
Exact dimensions may vary depending on type of range/cooktop
below.
t
15"
[38.1 cm)
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Observe all governing codes and ordinances.
Required:
[] A 120 Volt, 60 Hz, AC only, 15- or 20-amp electrical supply
with a fuse or circuit breaker.
Recommended:
[] A time-delay fuse or time-delay circuit breaker.
[] A separate circuit serving only this appliance.
GROUNDING INSTRUCTIONS
[] For all cord connected appliances:
The microwave oven must be grounded. In the event of
an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric
current. The microwave oven is equipped with a cord
having a grounding wire with a grounding plug. The plug
must be plugged into an outlet that is properly installed
and grounded.
WARNING: Improper use of the grounding plug can
result in a risk of electric shock. Consult a qualified
electrician or serviceman if the grounding instructions are
not completely understood, or if doubt exists as to whether
the microwave oven is properly grounded.
Do not use an extension cord. If the power supply cord is
too short, have a qualified electrician or serviceman install
an outlet near the microwave oven.
SAVE THESE INSTRUCTIONS
INSTALLATIONINSTRUCTIONS
NOTE: To avoid possible damage to the work surface, place a
protective cover on the work surface.
1. Remove any remaining contents from the microwave oven
cavity.
2. Remove the mounting plate by peeling off the strips of tape
that attach it to the back of the microwave oven, and set the
mounting plate aside.
A B C
®® ®o ®o
® ® /e
e e eemeeoeeoeeeeeoeeoeee_ee e
0"_ ...................... _0
® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ®
A. Back of microwave oven
B. Mounting plate
C. Tape (multiple locations)
3. Tape microwave oven door closed so that door does not
swing open while microwave oven is being handled.
NOTE: Do not grip or use the door or door handle while the
microwave oven is being manipulated.
%oteb Def eckx'
The microwave oven is set for ventless (recirculating) installation.
For wall or roof venting, changes must be made to the venting
system.
NOTE: Skip this section if you are using ventless (recirculating)
installation. Keep the damper assembly in case the venting
method is changed, or the microwave oven is reinstalled in
another location where wall or roof venting may be used.
Wall Venting Installation Only
1. Remove 5 screws attaching damper plate to top of microwave
oven exterior, then lift off damper plate.
A
A. Damper plate
2. Keep damper plate and screws together and set aside.
3. Slideairdeflectoroutofmicrowaveoven.
4.
5=
A.Air deflector
Rotate air deflector front to back so that deflector vanes face
the back of the microwave oven, and the exhaust port (open
end) of air deflector aligns with microwave oven exhaust port.
A
A. Microwave oven exhaust port
B. Air deflector exhaust port (open end)
C. Deflector vanes
Slide air deflector into the back of the microwave oven as
shown, making sure its exhaust port (open end) aligns with the
microwave oven exhaust port.
A
Roof Venting Installation Only
1.
2.
3.
4.
Repeat Step 1 from "Wall Venting Installation Only."
Repeat Step 2 from "Wall Venting Installation Only."
Repeat Step 3 from "Wall Venting Installation Only."
Rotate air deflector so that deflector vanes face the top of the
microwave oven, and the exhaust port (open end) of air
deflector aligns with microwave oven exhaust port.
A
5=
A. Microwave oven exhaust port
B. Deflector vanes
C. Air deflector exhaust port (open end)
Slide air deflector into the back of the microwave oven as
shown, making sure its exhaust port (open end) aligns with the
microwave oven exhaust port.
C
A. Microwave oven exhaust port
B. Air deflector exhaust port (open end)
C. Deflector vanes
6. Reattach damper plate with screws.
6=
A. Microwave oven exhaust port
B. Deflector vanes
C. Air deflector exhaust port (open end)
Reattach damper plate at corners with 4 screws. Save the fifth
screw for later use.
Lx}c@e S ud(s}
NOTE: If no wall studs exist within the cabinet opening, do not 1. Using a stud finder, locate the edges of the wall stud(s) within
install the microwave oven, the opening.
See illustrationsin "Possible Wall Stud Configurations," 2. Mark the center of each stud, and draw a plumb line down
each stud center. See illustrationsin "Possible Wall Stud
Configurations."
Possible Wall Stud Configurations
These depictions show examples of preferred installation configurations with the mounting plate.
No Wall Studs at Corner Holes
Figure 1
No Wall Studs at Corner Holes
Figure2
_i_ _i_
,ii'
i i I
i i
i i
NOTE: If wall stud is behind vent opening, only ventless
(recirculating) or roof venting installation can be done.
.D
One Wall Stud at Two Corner Holes
Figure3
Wall Studs at All Four Corner Holes
Figure4
A. Corner holes (on mounting plate)
B. Cabinet opening vertical centerllne
C. Wall vent opening (on mounting plate)
D. Wall stud centerllnes
E. Holes for lag screws
F. Support tabs
G. Mounting plate center markers
The microwave oven must be installed on a minimum of I wall
stud, preferably 2, using a minimum of 1 lag screw, preferably 2 or
more.
1. Using measuring tape, find and clearly mark the vertical
centerline of the opening.
A. Centerline
2. With the support tabs facing forward (see illustrations in
"Possible Wall Stud Configurations" in "Locate Wall Stud(s)"
section), align the mounting plate center markers to the
centerline on the wall, making sure it is level, and that the top
of the mounting plate is butted up against the bottom edge of
the upper cabinet.
NOTE: If the front edge of the upper cabinet is lower than the
back edge, lower the mounting plate so that its top is level with
the front edge of the cabinet.
A ........
C
B
A. Rear wall
B. Mounting plate
C. Top of mounting plate must align
with front edge of cabineL
D. Front edge of upper cabinet
3. Holding the mounting plate in place, mark the 4 corner holes.
4. Find the wall stud centerline(s) marked in Step 2 of "Locate
Wall Stud(s)," and mark at least 1, preferably 2 or more, hole(s)
through the mounting plate, closest to the centerline(s). See
figures 1, 2 and/or 3 in "Possible Wall Stud Configurations" in
"Locate Wall Stud(s)" section. The blackened holes in the
shaded areas are ideal hole locations.
5. Set mounting plate aside.
Wall Venting Installation Only
Centeriine
Upper CabinetBottom
J
IP
t
4" (10.2 cm)
6" (15.2 cm) 6" (15.2 cm)
6. Mark the centerline 3/8" (1 cm) down from the bottom edge of
the upper cabinet.
7. Using measuring tape, measure out 6" (15.2 cm) on both sides
of the centedine, and mark.
8. Measure down 4" (10.2 cm) from the mark made in Step 6,
and mark.
9. Using a straightedge, draw the 2 horizontal, level lines through
the marks made in steps 6 and 8.
10. Draw the 2 vertical, plumb lines down from the marks made in
Step 7 to complete the 12" x 4" (30.5 x 10.2 cm) rectangle.
This is the venting cutout area.
11. Cut a 3/4" (19 mm) hole in one corner of the cutout area.
12. Using a keyhole saw, cut out the venting cutout area.
In addition to being installed on at least 1 wall stud, the mounting
plate must attach to the wall at all 4 corner holes. If the holes are
not over wall studs, use four 1/4-20 x 3" round-head bolts with
toggle nuts; if 2 holes are over wall studs, use 2 each of lag
screws and 1/4-20 x 3" round-head bolts with toggle nuts; or if all
4 holes are over wall studs, use 4 lag screws. Following are 3
installation configurations.
Installation for No Wall Studs at Corner Holes
(Figures 1 & 2)
1. Drill 3/4" (19 mm) holes through the wall at all 4 corner holes
marked in Step 3 of "Mark Rear Wall."
2. Drill 3/16" (5 mm) hole(s) into the wall stud(s) at the hole(s)
marked in Step 4 of "Mark Rear Wall." Refer to figures 1 and 2
in "Possible Wall Stud Configurations" in "Locate Wall Stud(s)"
section.
Installation for One Wall Stud at Two Corner Holes
(Figure 3)
1. Drill 3/16" (5 mm) holes into the wall stud at the 2 corner holes
marked in Step 3 of "Mark Rear Wall."
2. If installing on a second wall stud, drill 3/16" (5 mm) hole(s)
into the wall stud at the holes marked in Step 4 of "Mark Rear
Wall." Refer to Figure 3 in "Possible Wall Stud Configurations."
in "Locate Wall Stud(s)" section.
3. Drill 3/4" (19 mm) holes through the wall at the other 2 corner
holes.
Installation for Wall Studs at All Four Corner Holes
(Figure 4)
1. Drill3/16" (5mm) holes into the studs atthe 4 corner holes
marked in Step 3 of "Mark RearWall."
NOTE: Secure the mounting plate to the wall at all 4 corner holes
drilled into the wall studs and/or drywall using either 1/4-20 x 3"
round-head bolts and toggle nuts or 1/4 x 2" lag screws.
Refer to illustrations in "Possible Wall Stud Configurations" in
"Locate Wall Stud(s)" section.
No Wall Studs at Corner Holes (Figures I & 2)
NOTE: The mounting plate must also be secured to the wall on at
least 1 wall stud as well as at all 4 corners.
1. With the support tabs of the mounting plate facing forward,
insert 1/4-20 x 3" round-head bolts through all 4 corner holes
of mounting plate.
2. Start toggle nuts on bolts from the back of the mounting plate.
Leave enough space for the toggle nuts to go through the wall
and open.
B
A. 1/4-20 x 3" round-head bolt
B. Mounting plate
C. Spring toggle nut
1
3. Position mounting plate on the wall, making sure that the top 1.
of the mounting plate is aligned with the front edge of the
upper cabinet. 2.
4. Push the 4 bolts with toggle nuts through the drywall, and 3.
finger tighten the bolts to make sure toggle nuts have opened
against drywall.
C
A. 1/4-20 x 3" round-head bolt
B. Mounting plate
C. Drywall
D. Spring toggle nut
5. Insert lag screw(s) into the holes drilled into wall stud(s) in
Step 2 of "Installation for No Wall Studs at Corner Holes" in
the "Drill Holes in Rear Wall" section.
6. Check alignment of mounting plate, making sure it is level.
7. Securely tighten all lag screws and bolts.
One Wall Stud at Two Corner Holes (Figure 3)
1. With the support tabs of the mounting plate facing forward,
insert 1/4-20 x 3" round-head bolts through the 2 corner holes
that fit over the two 3/4" (19 mm) holes drilled in Step 2 of
"Installation for One Wall Stud at Two Corner Holes" in the
"Drill Holes in Rear Wall" section.
2. Start toggle nuts on the bolts from the back of the mounting
plate. Leave enough space for the toggle nut to go through
the wall and to open.
3. Position mounting plate on the wall, making sure that the top
of the mounting plate is aligned with the front edge of the
upper cabinet.
4. Push the 2 bolts with toggle nuts through the drywall, and
finger tighten the bolts to make sure toggle nuts have opened
against drywall.
5. Insert 2 lag screws into the remaining 2 corner holes.
6. If installing on a second wall stud, insert lag screw(s) into the
other hole(s) drilled in Step 2 of "Installation for One Wall Stud
at Two Corner Holes" in the "Drill Holes in Rear Wall" section.
7. Check alignment of mounting plate, making sure it is level.
8. Securely tighten all lag screws and bolts.
Wall Studs at All Four Corner Holes (Figure 4}
1. Position mounting plate on the wall, making sure that the top
of the mounting plate is aligned with the front edge of the
upper cabinet.
2. Insert lag screws into the 4 corner holes.
3. Check alignment of mounting plate, making sure it is level.
4. Securely tighten all lag screws.
Disconnect power to outlet.
Remove all contents from upper cabinet.
Place Upper Cabinet Template against the bottom of the
upper cabinet, and attach with tape or thumbtacks. Make sure
the template centerline aligns with the vertical centerline on
the rear wall.
The "rear wall" arrows must be against the rear wall so that the
holes cut into the upper cabinet align with the holes in the top
of the microwave oven.
NOTE: If the upper cabinet has a frame around it, trim the
template edges so that it fits inside the frame, against the upper
cabinet bottom. The template has trim lines to use as guides.
4. Make sure the 107_6'' (26.5 cm) dimension from the rear wall to
points "D" and "E" on the template is maintained.
O O
\
5. Cut the 11/2"(3.8 cm) diameter hole at the circular shaded area
"G" on the template. This hole is for the power supply cord.
NOTE: If upper cabinet is metal, the supply cord bushing needs to
be installed around the supply cord hole, as shown.
A ......................................................
%_ f
A. Metal cabinet
B. Power supply cord bushing
6. Drill 3/8" (10 mm) holes at points "D" and "E" on the template.
These are for two 1/4-20 x 3" round-head bolts and washers
used to secure the microwave oven to the upper cabinet.
For Roof Venting Installation Only
7. Cut 3/4" (19 mm) hole at one corner of the shaded rectangular
area "F" on Upper Cabinet Template.
8. Using a keyhole saw, cut out the rectangular area.
1.
2.
©empe A ruby
Check that damper blade moves freely, and opens toward the
wall fully.
Push damper assembly through opening in mounting plate so
that tabs in damper assembly lock damper assembly against
mounting plate. Long tab of damper assembly must be to left
side of mounting plate.
A ....
B
C
A. Mounting plate
B. Mounting plate opening
C. Damper assembly
D. Long tab
E, Damper blade
ns xs the Mc Oven
Excessive Weight Hazard
Use two or more people to move and install
microwave oven.
Failure to do so can result in back or other injury.
IMPORTANT: The control side of the unit is the heavy side.
Handle the microwave oven gently.
1. Place a washer on each 1/4-20 x 3" bolt and place inside
upper cabinet near the 3/8" (10 mm) holes.
2. Make sure the microwave oven door is closed and taped shut.
II
3.
support tabs at the bottom of mounting plate.
NOTE: Do not grip or use the door or door handle during
installation.
Using 2 or more people, lift microwave oven and hangit on
A. Mounting plate
B. Support tabs
10
4.
With front of microwave oven still tilted, thread power supply
cord through the power supply cord hole in the bottom of the
upper cabinet.
For Roof Venting Installation Only
1. Insert damper assembly through the cabinet cutout so that the
long tab of the damper assembly slides under the raised tabs
of the damper plate. Then secure with screw removed in
Step 1 of "Rotate Air Deflector."
NOTE: The screw cannot be installed if the damper assembly is
not positioned as shown.
B C
5. Rotate microwave oven up toward upper cabinet.
NOTE: If venting through the wall, make sure the damper
assembly fits easily into the vent tube in the wall cutout.
6. Push microwave oven against mounting plate and hold in
place.
NOTE: If microwave oven does not need to be adjusted, skip
steps 7-9.
7. If adjustment is required, rotate microwave oven downward.
Using 2 or more people, lift microwave oven off of mounting
plate, and set aside on a protected surface.
8. Loosen mounting plate screws. Adjust mounting plate and
retighten screws.
9. Repeat steps 3-6.
10. With the microwave oven centered, and with at least one
person holding it in place, insert bolts through upper cabinet
into microwave oven. Tighten bolts until there is no gap
between upper cabinet and microwave oven.
NOTES:
Some upper cabinets may require bolts longer or shorter than
3" (7.6 cm). Longer or shorter bolts are available at most
hardware stores.
Overtightening bolts may warp the top of the microwave oven.
To avoid warping, wood filler blocks may be added. The
blocks must be the same thickness as the space between the
upper cabinet bottom and the microwave oven.
2.
E
A. Raised tabs
B. Damper assembly
C. Screw
D. Upper cabinet cutout
E. Long tab
F. Damper plate
Connect vent to damper assembly.
A B
i_i ii
[
II niF -I
A. Vent
B. Damper assembly (under vent)
A. Bolts
11
Comp @e cJf<'n
Refer to the Use and Care Guide for instructions on how to
install filters into your model.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
ASSISTANCE
Call your authorized dealer or service center. When you call, you
will need the microwave oven model number and serial number.
Both numbers can be found on the model and serial number
plate, which is located behind the microwave oven door on the
front frame of the microwave oven.
If you need additional assistance, call us at our toll free number
listed in the Use and Care Guide, or visit us on the Web.
If any of the installation hardware needs to be replaced, call us at
our toll free number listed in the Use and Care Guide, and
reference the appropriate part number listed here.
Damper Assembly
Part Number 8205558
Mounting Plate
Part Number 8205400
Upper Cabinet Template
Part Number 8205928
Mounting Screw Kit (includes
parts A-E in "Parts Supplied"
section)
Part Number 8205947
2=
3.
4.
5=
Plug microwave oven into grounded 3 prong outlet.
Reconnect power.
Check the operation of microwave oven by placing 1cup
(250 mL) of water on the turntable, and programming a cook
time of I minute at 100% power. Test vent fan and exhaust by
operating the vent fan.
If the microwave oven does not operate:
Check that a household fuse has not blown, or a circuit
breaker tripped. Replace the fuse or reset the circuit
breaker. If the problem continues, call an electrician.
Check that the power supply cord is plugged into a
grounded 3 prong outlet.
See the Use and Care Guide for troubleshooting
information.
Installation is now complete.
Save Installation Instructions for future use.
Filler Panel Kits are available from your dealer to use when
installing this microwave oven in a 36" (91.4 cm) or 42" (106.7 cm)
wide opening. The filler panels come in pairs. Each panel is 3"
(7.6 cm) wide.
o1[o
JE
Filler Panel Kit Number 8171336 White
8171337 Black
8171338 Biscuit
8171339 Stainless Steel
99403 Almond
See your authorized dealer or service center for details.
12
SECURITEDE L'ENSEMBLEFOURA MICRO-ONDES/HOTTE
Votre s_curit_ et celle des autres est tres importante.
Nous donnons de nombreux messages de securite importants dans ce manuel et sur votre appareil menager. Assurez-vous de
toujours lire tousles messages de securite et de vous y conformer.
Voici le symbole d'alerte de securite.
Ce symbole d'alerte de securite vous signale les dangers potentiels de deces et de blessures graves &vous
eta d'autres.
Tous les messages de securite suivront le symbole d'alerte de securite et le mot "DANGER" ou
"AVERTISSEMENT'. Ces mots signifient :
Risque possible de deces ou de blessure grave si vous ne
suivez pas immediatement les instructions.
Risque possible de deces ou de blessure grave si vous
ne suivez pas les instructions.
Tousles messages de securite vous diront quel est le danger potentiel et vous disent comment reduire le risque de blessure et
ce qui peut se produire en cas de non-respect des instructions.
SPECIFICATIONS/CONCEPTION DU CIRCUITD'EVACUATION
Cette section presente de I'information de reference uniquement, a I'intention des architectes/concepteurs et constructeurs.
REMARQUES :
Les materiaux du circuit d'evacuation necessaires &
I'installation ne sent pas fournis avec I'ensemble four a micro-
ondes/hotte.
On deconseille I'emploi d'un conduit metallique flexible.
Pour eviter d'eventuelles deteriorations du produit, veiller a ce
que I'air aspire soit decharge a I'exterieur (sauf dans le cas
d'une installation avec recyclage). Veiller a ce que I'air aspire
ne soit pas decharge dans un espace ferme dissimule (cavite
dans une cloison), au-dessus du plafond, grenier, vide
sanitaire ou garage.
Recommandations pour une installation optimale du
circuit d'_vacuation :
utiliser une bouche de decharge (murale ou sur toit)
comportant un clapet anti-reflux
utiliser un conduit metallique rigide
utiliser I'itineraire d'acheminement le plus direct; minimiser la
Iongueur du circuit et le nombre de coudes pour obtenir un
fonctionnement efficace
utiliser des conduits de taille uniforme
Decharge a travers le toit Bouche de decharge sur toit
assurer I'etancheite de toutes les jointures des conduits avec
du ruban adhesif pour conduits
utiliser un compose de calfeutrage pour assurer I'etanch6it6
autour de la bouche de decharge (murale ou sur toit)
ne pas connecter ensemble 2 raccords coudes, pour
optimiser la performance de la hotte
Dans le cas de la decharge &travers lemur, veiller a disposer de
I'espace libre suffisant a I'interieur du mur pour que le clapet anti-
reflux puisse manceuvrer librement.
Dans le cas de la decharge atravers le toit, si on dolt utiliser un
raccord de transition (de rectangulaire a rond), veiller a disposer
d'un espace libre d'au moins 3" (7,6 cm) entre le sommet du four
micro-ondes et le raccord de transition. Voir I'illustration
"Raccord de transition rectangulaire/rond".
Decharge a travers le mur Bouche de decharge murale
13
Raccord de transition rectangulaire/rond
REMARQUE :On doit disposer d'un espace libre de 3" (7,6 cm)
ou plus entre le sommet du four & micro-ondes et le raccord de
transition rectangulaire/rond pour que le clapet anti-reflux puisse
manceuvrer librement et completement.
B
C
A. Bouche de d_charge sur toit
B. Conduit fond dia. 6" (15,2 cm) min.
C. Coude (pour d_charge murale uniquement)
D. Bouche de d_charge murale
E.Raccord de transition rectangulaire/rond 3Y4"x 10" b
dia. 6" (8,3x25,4 cm a !5,2cm)
F. Raccord d'extension, Iongueur de 3" (7,6 cm) min.
Raccords standard recommand_s
Les Iongueurs equivalentes suivantes doivent _tre utilisees pour
calculer la Iongueur du circuit d'evacuation. Voir les exemples
dans la section "Longueur recommandee du circuit d'evacuation'.
A B C
E F G
A. Raccord de transition rectangulaire/rond : 3Y4" x 10" a dia. 6"=
5 pi (8,3 x 25,4 cm a !5,2cm = 1,5m)
B. Bouche de d_charge sur toit : 3 1/4"x 10" = 24 pi (8,3 x 25,4 cm
=7,3m)
C. Coude a gO° : 3 !/4"x 10" = 25 pi (8,3 x 25,4 cm = 7,6m)
D. Coude a gO° : 6" = 10pi (15,2 cm =3 m)
E.Bouche de d_charge murale : 3 1/4" x !0" = 40 pi (8,3 x 25,4 cm
= !2,2 m)
F. Coude a 45° : 6'' = 5 pi (15,2 cm = 1,5m)
G. Coude a 90° plat : 3 1/4"x 10" = 10 pi (8,3 x 25,4 cm = 3 m)
Longueur recommand_e du circuit d'6vacuation
On devrait utiliser un conduit rectangulaire 31/4'' x 10" (8,3 x
25,4 cm), ou un conduit rond de dia. 6" (15,2 cm).
La Iongueur equivalente totale du circuit d'evacuation, ceci
incluant les sections de conduit rectilignes, coude(s), raccords de
transition et bouche de decharge murale ou sur toit, ne doit pas
depasser 140 pi (42,7 m) quel que soit le type de conduit. Les
Iongueurs equivalentes des divers composants sont mentionnees
dans la section "Raccords standard recommandes".
Pour optimiser la performance, ne pas utiliser plus de trois coudes
&90°.
Pour calculer la Iongueur equivalente du systeme necessaire,
totaliser les valeurs de Iongueur equivalente pour tous les
composants utilises dans le circuit. Voir les exemples suivants :
Conduit de 31/4''x 10" (8,3 x 25,4 cm) = Iongueur totale 73 pi
(22,2 m)
A
epi (1,8m)
'°,°m'±U
C
B
A. Un coude a 90° 3¼" x 10" (8,3 x 25,4 cm) = 25 pi (7,6 m)
B. 1 bouche de d_charge murale = 40 pi (12,2 m)
C. Sections de conduit rectiligne 2 pi (0,6 m) + 6 pi (1,8 m) = 8 pi
(2,4 m)
Conduit de dia. 6" (15,2 cm) = Iongueur totale 73 pi (22,2 m)
H
c
_[ 6 pi (1,8 m)
B
D
A. Deux coudes a 90 ° = 20 pi (6,1 m)
B. 1 bouche de d_charge murale = 40 pi (12,2 m)
C. Raccord de transition conduit rectangulaire/conduit fond = 5 pi
(!,5 m)
D. Sections de conduit rectiligne 2 pi (0,6 m) + 6 pi (1,8 m) = 8 pi
(2,4 m)
Si le circuit d'evacuation existant est fait de conduit rond, on doit
utiliser un raccord de transition de conduit rectangulaire a conduit
rond. De plus on devra utiliser une extension de conduit
rectangulaire de 3" (7,6 cm) entre le clapet anti-reflux et le raccord
de transition rectangulaire/rond, pour eviter toute entrave a la
manceuvre du clapet anti-reflux.
14
EXIGENCESD'INSTALLATION
Outillage n_cessaire
Rassembler les outils et pieces necessaires avant de commencer
I'installation. Lire et suivre les instructions fournies avec les outils
mentionnes ici.
Metre ruban Detecteur magnetique
(detection des poteaux du
Crayon colombage)
Ruban de masquage ou Cle a douille de 7/16" (ou
punaises cle mixte), pour vis
Ciseaux d'ancrage de 1/4" x 2"
Tournevis Phillips n° 2 Scie a trou de 1_/2"(3,8 cm)
de diametre pour placard de
Tournevis Phillips n° 3 (pour bois ou metallique
visa t6te ronde de 1/4-20 x
3") Scie a guichet
Perceuse electrique Pistolet a calfeutrage et
compose de calfeutrage
Meches de 3/16" (5 mm) et resistant aux intemperies
3/8" (10 mm)
Ruban adhesif pour conduit
Scie a guichet de 3/4"
(19 mm)
Pi_ces fournies
Pour la commande de pieces, voir la section "Pieces de
rechange".
REMARQUE : Les articles de quincaillerie presentes ci-dessous
sont destines & I'utilisation sur un colombage de bois. En
presence d'une structure de mur different, utiliser les organes de
fixation appropries.
F
}
A. Visa t_te ronde de 1/4-20x3"(6)
B. Rondelles (2)
C. Ecrous articul_s (4)
D. Vis d'ancrage 1/4" x 2" (4)
E. Garniture pour trou de passage du
cordon d'alimentation (1)
F Module de clapet anti-reflux (pour
d_charge a travers lemur ou le toit)
Composants non illustr_s :
Gabarit pour placard mural
Plaque de montage (fixation
I'arriere du four a micro-
ondes)
Filtres a graisse en
aluminium
Filtres a charbon (selon le
modele, les flltres a charbon
peuvent ne pas _tre inclus.
Voir le Guide d'utilisation et
d'entretien.)
Mat_riaux n_cessaires
Composants standard pour decharge a travers lemur ou
travers le toit Voir la section "Specifications/conception du
circuit d'evacuation'.
Inspecter I'espace ou le four a micro-ondes sera installe.
L'emplacement d'installation dolt disposer de :
Dimensions minimales a respecter Iors de I'installation. Voir
I'illustration "Dimensions a respecter Iors de I'installation'.
Au moins un poteau de colombage en bois 2" x 4"
(50,8 x 101,6 mm), et parement de pl&tre ou panneau de
gypse d'epaisseur 3/8" (9,5 mm) ou plus, dans I'ouverture du
placard.
Capacite de support de charge de 150 Ib (68 kg), ceci incluant
le four a micro-ondes et les articles places a I'interieur du four
micro-ondes et du placard mural.
Prise de courant electrique reliee &la terre & I'int@ieur du
placard mural. Voir la section "Specifications electriques".
REMARQUES :
Dans le cas de I'installation du four a micro-ondes a proximite
d'une paroi laterale sur le c6te gauche, veiller a laisser un
espace libre de 6" (15,2 cm) ou plus entre lemur et le four
micro-ondes, pour permettre la manoeuvre d'ouverture
complete de la porte.
Les materiaux de certains placards et certains mat@iaux de
construction ne sont pas congus pour resister a la chaleur
emise par le four a micro-ondes Iors des op@ations de
cuisson. Consulter le constructeur de la maison ou le fabricant
des placards pour determiner si les materiaux utilises
pourraient subir un changement de couleur, une
destratification ou d'autres dommages.
Exigences sp_ciales
Pour une installation avec d_charge murale seulement :
L'ouverture de 12" x 4" (30,5 x 10,2 cm) &decouper dolt @re
alignee avec I'ouverture rectangulaire de la plaque de
montage.
L'ouverture decoupee dolt _tre exempte d'obstruction pour
I'ajustement adequat du conduit d'evacuation, et pour que le
clapet anti-reflux puisse manoeuvrer completement et
librement.
Pour une installation avec d_charge & I'ext_rieur & travers
le toit seulement :
S'il est necessaire d'utiliser un raccord de transition, on dolt
disposer d'un espace libre de 3" (7,6 cm) au-dessus du four
micro-ondes pour que le clapet anti-reflux puisse manoeuvrer
completement et librement. Voir I'illustration "Raccord de
transition rectangulaire/rond" a la section "Specifications/
conception du circuit d'evacuation".
REMARQUE :Selon le modele de I'appareil, le filtre a graisse en
aluminium et le filtre a charbon peuvent _tre combines.
15
Dimensions & respecter Iors de rinstallation
REMARQUE : La prise de courant fl 3 alveoles reliee & la terre dolt
_tre situee & I'interieur du placard mural. Voir la section
"Specifications electriques".
A B
66" (167,6 cm) min.
30" (76,2 cm) typique*
lz' (3o,sore)
rail3.
" 5,6 cm) max.
@ @ @ @
............
A, Poteau du colombage mural de 2" x 4"
B, Prise a 3 alv6oles reli_e a la terre
t; .........
*30" (76,2 cm) est typique pour une hauteur d'installation de 66"
(167,6 cm). Les dimensions exactes peuvent varier en fonction
du type de cuisiniere/table de cuisson di-dessous.
T
161/4 `'
(41,3 cm)
t
15"
[38,1 cm)
l
Risque de choc electrique
Brancher sur une prise a 3 alveoles reliee a la terre.
Ne pas enlever la broche de liaison a la terre.
Ne pas utiliser un adaptateur.
Ne pas utiliser un c_ble de rallonge.
Le non-respect de ces instructions peut causer
un d@ces, un incendie ou un choc electrique.
Observer les dispositions de tous les codes et reglements en
vigueur.
N_cessaire :
[] Une alimentation electrique de 120 volts, 60 Hz, CA
seulement, 15 ou 20 amperes, protegee par fusibles ou
disjoncteur.
Recommand@ :
[] Un fusible temporise ou un disjoncteur temporise.
[] Un circuit distinct exclusif a cet appareil.
INSTRUCTIONS DE MISE .&.LA TERRE
[] Pour tout appareil menager connecte par un cordon
de courant electrique :
IIfaut que le four & micro-ondes soit relie & la terre. En
cas de court-circuit electrique, la liaison &la terre reduit le
risque de choc electrique car le courant electrique
dispose d'un itineraire direct d'acheminement & la terre.
Le four & micro-ondes est dote d'un cordon de courant
electrique qui comporte un fil de liaison &la terre, avec
broche de liaison & la terre. On dolt brancher la fiche sur
une prise de ceurant convenablement installee et reliee &
la terre.
AMERTISSEMENT : L'utilisation incorrecte du
dispesitif de liaison & la terre peut susciter un risque de choc
electrique. L'utilisateur qui ne comprend pas bien les
instructions de liaison &la terre, ou qui n'est pas certain que
le four & micro-ondes soit convenablement relie& la terre,
devrait consulter un electricien qualifie.
Ne pas utiliser un c&ble de rallonge. Si le cordon de
courant electrique est trop court, demander & un
electricien qualifie d'installer une prise de courant &
proximite du four & micro-ondes.
CONSERVEZ CES INSTRUCTIONS
16
INSTRUCTIONSD'INSTALLATION
2.
REMARQUE : Placer un materiau de protection sur la surface de
travail pour eviter de I'endommager.
1. Retirer de la cavite du four a micro-ondes tousles articles qui
peuvent s'y trouver.
2. Enlever la plaque de montage : enlever les morceaux de ruban
adhesif fixant la plaque de montage sur la face arriere du four
micro-ondes et mettre la plaque de montage de c6t&
A B C
\
m
\
r t.. .
® ®- /e ® e
e eemeeeeeemeeeeeeeemeemee m m m ®
0"_ ...................... _'0
= ® ® ® ® ® ® ® ® ® ® ® ® ® ® e ® ® ® ®
Conserver ensemble la plaque de support du clapet et les vis.
Separer le deflecteur du four a micro-ondes (faire glisser).
A. Face arriere du four a micro-ondes
B. Plaque de montage
C. Ruban adh_sif (en plusieurs endroits)
3. Utiliser du ruban adhesif pour immobiliser la porte fermee du
four a micro-ondes, pour qu'elle ne puisse pas s'ouvrir durant
les manutentions du four.
REMARQUE : Ne pas prendre prise sur la porte ou la poignee de
la porte durant les manutentions du four a micro-ondes.
4.
A. D_flecteur d'air
Faire pivoter le deflecteur d'air de I'avant vers arriere, pour
que les pales du deflecteur soient orientees vers I'arriere du
four a micro-ondes, et pour que I'orifice de sortie (extremite
ouverte) du deflecteur d'air soit aligne avec I'orifice de
decharge du four a micro-ondes.
A
A. Orifice de d_charge du four a micro-ondes
B. Orifice de sortie du d_flecteur d'air (extr_mit_
ouverte)
C. Pales de d_flexion
Le four & micro-ondes a ete configure &I'usine pour une
installation avec recyclage, sans d_charge &I'exterieur. Pour la
decharge de I'air aspire & travers lemur ou &travers le toit, on dolt
modifier le systeme de ventilation du four.
REMARQUE :Si le produit est destine & _tre utilise sans
decharge a I'ext_rieur (avec recyclage de I'air), ne pas tenir
compte de cette section. Conserver le module du clapet pour le
cas ou une autre methode d'evacuation serait utilisee
ulterieurement ou dans le cas ou le four a micro-ondes serait
reinstalle ulterieurement en un autre endroit, avec decharge
I'exterieur a travers lemur ou a travers le toit.
Pour une installation avec d_charge murale seulement
1. 0ter les 5 vis fixant la plaque de support du clapet a la partie
superieure de I'exterieur du four a micro-ondes; soulever
ensuite la plaque de support du clapet pour I'enlever.
A
A. Plaque de support du clapet
17
5=
Inserer le deflecteur d'air & I'arriere du four a micro-ondes,
comme sur I'illustration; veiller ace que I'orifice de sortie
(extremite ouverte) soit aligne avec I'orifice de decharge du
four a micro-ondes.
4=
Faire pivoter le deflecteur d'air, pour que les pales du
deflecteur soient orientees vers le sommet du four a micro-
ondes, et pour que I'orifice de sortie (extremite ouverte) du
deflecteur d'air soit aligne avec I'orifice de decharge du four
micro-ondes.
A. Orifice de d_charge du four a micro-ondes
B. Orifice de sortie du d_flecteur d'air
(extr_mit# ouverte)
C. Pales de d_fiexion
6. Reinstaller la plaque de support du clapet avec les vis.
5=
A. Orifice de d_charge du four a micro-ondes
B. Pales de d_flexion
C. Orifice de sortie du d_flecteur d'air (extr_mit_
ouverte)
Inserer le deflecteur d'air a I'arriere du four & micro-ondes,
comme sur I'illustration; veiller ace que I'orifice de sortie
(extremite ouverte) soit aligne avec I'orifice de decharge du
four a micro-ondes.
A
Pour une installation avec d_charge & I'ext_rieur
travers le toit seulement
1. Repeter I'etape 1 de "Pour une installation avec decharge
murale seulement".
2. Repeter I'etape 2 de "Pour une installation avec decharge
murale seulement".
3. Repeter I'etape 3 de "Pour une installation avec decharge
murale seulement'.
6=
A. Orifice de d_charge du four a micro-ondes
B. Pales de d_flexion
C. Orifice de sortie du d_flecteur d'air
(extr_mit_ ouverte)
Reinstaller la plaque de support du clapet avec les 4 vis.
Conserver la 5e vis pour utilisation ulterieure.
18
c_poson (A,,5/d®spo ®<xuxdu co omb<xg® s_u {s
REMARQUE : S'il n'y a aucun poteau du colombage dans la zone 1. Utiliser un detecteur magnetique de clou/vis pour Iocaliser
delimit6e par I'ouverture dans le placard mural, ne pas installer le dans I'ouverture les rives des poteaux du colombage mural.
four a micro-ondes. 2. Marquer la position du centre de chaque poteau du
Voir les illustrations a la section "Configurations possibles du colombage, et tracer I'axe de chaque poteau a I'aide d'un fil
colombage mural", plomb. Voir les illustrations & la section "Configurations
possibles du colombage mural".
Configurations possibles du colombage mural
Les illustrations ci-dessous presentent des exemples de configurations preferentielles d'installation avec la plaque de montage.
Aucun poteau du colombage & la position des trous des
angles
Figure 1
Aucun poteau du colombage & la position des trous des
angles
Figure2
i
i
i
i
i
_i _
i
i
i
J
I
;I
i
i
,D
Deux trous des angles face & un poteau du colombage
mural
Figure3
REMARQUE :Si le poteau du colombage se trouve derriere
I'ouverture de passage du conduit d'evacuation, on ne pourra
utiliser que la configuration sans decharge &I'exterieur
(recyclage) ou celle de I'evacuation par le toit.
Quatre trous des angles face & un poteau du colombage
mural
Figure 4
.................. o' _ A E................ I .............. _ _...............A E
I ..................... i II .................... ' ...................
.... o o "o o o o " .......................
G ....... " ...... I I .........
oOo .............................÷ ,)o...... : :.... :.: ................_ r .......
Ioo o ,_ _ <ooooooooooooooooooooooo o o o o o o o o o o o o oooooooooooooooooooooooo o o o o o o
', i, ;
B' 4 "'-:::,,_,E B......................:.....................................................................................
i
A E .......................... _,odo .......
_.V".... / I
F i // i F
:i' / ! i:
D..................i / _ : r,y,.,,.,,,,D
G ! / !G ¸
i
A. Trous des angles (sur la plaque de montage)
B.Axe vertical central de I'ouverture dans le placard
C. Ouverture pour d_charge a travers lemur (dans la plaque de montage)
D.Axe central de poteau du colombage
E. Trous pour vis d'ancrage
Pattes de support
G. Reperes centraux sur la plaque de montage
19
Le four & micro-ondes dolt _tre fixe sur au moins un poteau du
colombage mural, et de preference sur 2 poteaux; on utilise pour
cela au moins 1 vis d'ancrage, et de preference 2 vis ou plus.
1. Utiliser un metre-ruban; determiner et marquer clairement la
position de I'axe central vertical de I'ouverture.
A. Axe central
2. Alors que les deux pattes de support sont orientees vers
I'avant (voir les illustrations a la section "Configurations
possibles du colombage mural" a la section "Identifier la
position du/des poteaux du colombage mural"), aligner les
reperes centraux sur la plaque de montage avec I'axe central
sur lemur; veiller au bon aplomb, et veiller ace que le sommet
de la plaque de montage soit en contact contre le bord
inferieur du placard mural.
REMARQUE : Si la rive avant du placard mural est plus basse
que la rive arriere, abaisser la plaque de montage de maniere ace
que le sommet de la plaque de montage soit au m_me niveau que
la rive avant du placard.
A ........................
C
B
A. Mur arriere
B. Plaque de montage
C. Le sommet de la plaque de montage dolt
_tre align_ avec la rive avant du placard.
D. Rive avant du placard mural
3. Maintenir la plaque de montage en place et marquer la
position des 4 trous des angles.
4. Trouver I'axe central des poteaux du colombage marques
I'etape 2 de la section "Identifier la position du/des poteaux
du colombage mural", et marquer la position d'au moins 1,
et de preference 2 ou plus, trou(s) & travers la plaque de
montage - le plus pres possible de I'axe central de chaque
poteau du colombage. Voir les figures 1, 2 et/ou 3 de la
section "Configurations possibles du colombage mural" a la
section "Identifier la position du/des poteaux du colombage
mural". Les trous a utiliser de preference sont ceux qui sent
marques en noir dans les zones grisees.
5. Conserver laplaque de montage a part.
Pour une installation avec d_charge murale seulement
Axe central_ _ Fond d_card mural
t
4" (10,2 cm)
6" (15,2 cm)
f 3/8"(1cm)
6" (15,2 cm)
6. Marquer un point sur I'axe central a 3/8" (1 cm) au-dessous de
la rive inferieure du placard mural.
7. Utiliser un m_tre-ruban; marquer un point a 6" (15,2 cm) de
chaque c6te de I'axe central.
8. Marquer un point a 4" (10,2 cm) au-dessous de la marque
tracee a I'etape 6.
g. Utiliser une regle; tracer 2 lignes horizontales entre les
marques tracees aux etapes 6 et 8.
10. Tracer 2 lignes verticales a partir des marques faites a I'etape
7, pour obtenir un rectangle complet de 12" x 4"
(30,5 x 10,2 cm). Ce rectangle delimite la zone a decouper
pour le passage du conduit d'evacuation.
11. Decouper un trou de 3/4" (19 mm) dans un coin de la zone
decouper.
12. A I'aide d'une scie a guichet, decouper la zone a decouper
pour le passage du conduit d'evacuation.
t9® C,_ oe '......
En plus de la fixation sur au moins 1 poteau du colombage, on
dolt egalement fixer la plaque de montage sur lemur au niveau
des 4 trous des angles. Si la position des trous ne cd_ncide pas
avec des poteaux du colombage, utiliser quatre visa t_te ronde
de 1/4-20 x 3" avec ecrou articule; s'il y a 2 trous en cdfncidence
avec les poteaux de colombage, utiliser 2 vis d'ancrage, et 2 vis
t_te ronde de 1/4-20 x 3" avec ecrou articule; s'il y a 4 trous en
cd_ncidence avec les poteaux de colombage, utiliser 4 vis
d'ancrage. On presente ci-dessous 3 configurations d'installation.
Aucun trou des angles en cd_'ncidence avec les poteaux
du colombage (Figures I et 2)
1. Percer des trous de 3/4" (19 mm) a travers lemur
I'emplacement des 4 trous des angles marques a I'etape 3 de
la section "Trace sur lemur arriere".
2. Percer des trous de 3/16" (5 mm) dans les poteaux de
colombage a I'emplacement des trous marques a I'etape 4 de
la section "Trace sur le mur arriere". Voir les figures 1 et 2 de la
section "Configurations possibles du colombage mural" a la
section "Identifier la position du/des poteaux du colombage
mural".
2O
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Whirlpool YGH8155XMQ1 Guide d'installation

Taper
Guide d'installation

dans d''autres langues