Date Issued: 09/18/17 IS-45910-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starting and during the installation.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
A
B
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth)
*Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
1
4
7
5
6
8
2
3
1) Find the appropriate threaded holes on mounting strap[1]. As-
semble mounting screws[2] into threaded holes.
2) Attach mounting strap to outlet box[3]. Mounting strap can be
adjusted to suit position of xture.
3) Grounding instructions: (See Illus. A or B)
A) On xtures where mounting strap is provided with a hole
and two raise dimples. Wrap ground wire from outlet box
around green ground screw, and thread into hole.
B) On xtures where a cupped washer is provided. Put
ground wire from outlet box under cupped washer and
green ground screw and thread screw into hole in mount-
ing strap.
If xture is provided with ground wire. Connect xture ground
wire to outlet box ground wire with wire connector, after follow-
ing the above steps. Never connect ground wire to black or
white power supply wires.
4) Make wire connections. Reference chart below for correct con-
nections and wire accordingly
5) Push xture to wall carefully passing mounting screws with
holes in canopy[4]. NOTE: Make sure all wires are inside cano-
py and do not get pinched between wall and canopy of xture.
6) Thread lockup knobs[6] onto mounting screws[2] and tighten
to secure xture to wall.
7) Carefully raise glass[6] to the xture. Slip the smaller opening
over the socket[7] and t the glass against the socket.
8) Thread the socket ring[8] onto the socket. Tighten socket ring
to secure glass in place (DO NOT over tighten).
9) Insert recommended bulb (not supplied).