3com SS3 BASELINE 100/1000 SW 6-PORT Manuel utilisateur

Catégorie
Commutateurs réseau
Taper
Manuel utilisateur

Ce manuel convient également à

The SuperStack
®
3 Baseline 10/100/1000 Switch 6-Port
10BASE-T/100BASE-TX/1000BASE-T is a versatile,
easy-to-use switch. It is ideal for users who want the
high-speed performance of 10/100/1000 switching but
do not need sophisticated management capabilities. The
Baseline 10/100/1000 Switch 6-Port is shipped ready for
use. No configuration is necessary.
The Baseline 10/100/1000 Switch 6-Port can be rack-
mounted or free standing.
The Baseline 10/100/1000 Switch 6-Port includes:
One power cord
One mounting kit
Four standard height self-adhesive feet
A card with details of online registration
The Switch can be powered either from the AC mains
supply, or through an optional 3Com
®
SuperStack 3
Advanced Redundant Power System (3C16071A).
Contact your supplier for details.
The Baseline 10/100/1000 Switch 6-Port provides high
performance switched connections to 10 Mbps, 100
Mbps, and 1000 Mbps hubs, switches, servers and
workstations that need a dedicated switched link. The
following figure illustrates one possible configuration.
The Baseline 10/100/1000 Switch 6-Port has 6 shielded
RJ-45, 10/100/1000 Mbps auto-negotiating ports on the
front panel. Each 10/100/1000 Mbps port automatically
determines the speed, duplex mode, and MDIX mode of
the connected equipment and provides a suitable
switched connection. Note that 1000BASE-T connections
operate in full duplex mode only.
All Switch ports support flow control, which is a
mechanism that prevents packet loss during periods of
congestion on the network. Packet loss is caused by one
or more devices sending traffic to an already overloaded
port on the Switch. Flow control prevents packet loss by
I
NTRODUCTION
Baseline 10/100/1000 Switch
Baseline 10/100 Switches
1000Mbps
connections
Servers with
1000Mbps
connections
Baseline Hub
with 10Mbps connection
1
SuperStack
®
3 Baseline 10/100/1000 Switch 6-Port
10BASE-T/100BASE-TX/1000BASE-T (3C16468) User Guide
DUA1646-8AAA02
inhibiting the devices from generating more packets until
the period of congestion ends.
Flow control is implemented using the IEEE 802.3x
standard for ports operating in full duplex mode.
The Baseline 10/100/1000 Switch 6-Port supports a
maximum of 8,192 MAC addresses.
The numbers in this diagram refer to numbered sections
in the text.
Front Panel
1 6 RJ-45 10/100/1000 Ports
WARNING
: RJ-45 ports.
These are shielded RJ-45 data
sockets. They cannot be used as telephone sockets. Only
connect RJ-45 data connectors to these sockets. Either
shielded or unshielded data cables with shielded or
unshielded jacks can be connected to these data
sockets.
AVERTISSEMENT: Les ports RJ-45.
Il s’agit de prises
femelles blindées de données RJ-45. Vous ne pouvez pas
les utiliser comme prise de téléphone. Branchez
uniquement des connecteurs de données RJ-45 sur ces
prises femelles. Les câbles de données blindés ou non
blindés, avec les jacks blindés ou non blindés, l’un ou
l’autre, peuvent être branchés à ces prises de courant de
données.
WARNUNG: RJ-45-Anschlüsse.
Dies sind abgeschirmte
RJ-45-Datenbuchsen. Sie können nicht als Telefon-
anschlußbuchsen verwendet werden. An diesen Buchsen
dürfen nur RJ-45-Datenstecker angeschlossen werden.
Diese Datenstecker können entweder mit abgeschirmten
oder unabgeschirmten Datenkabeln mit abgeschirmten
oder unabgeschirmten Klinkensteckern verbunden
werden.
The Baseline 10/100/1000 Switch 6-Port has 6
10/100/1000 Mbps auto-negotiating ports. Each port
automatically determines the correct speed and duplex
mode as one of the following:
10BASE-T half duplex
10BASE-T full duplex
100BASE-TX half duplex
100BASE-TX full duplex
1000BASE-T full duplex
CAUTION:
The Baseline 10/100/1000 Switch 6-Port
supports full duplex auto-negotiation. If the connected
device does not support auto-negotiation, the Switch will
operate in half duplex mode (even if the device is
operating in full duplex mode). In such a configuration,
you may notice some degradation of network
performance. 3Com recommends that you use devices
that are capable of auto-negotiation (and that you ensure
that auto-negotiation is enabled, if it is a configurable
option).
All ports auto-sense an MDI/MDIX connection and can
be used to connect to either another switch port, server,
or workstation without additional configuration. Each
port can be connected to a device with a normal
straight through TP (twisted pair) cable or a cross-over
TP cable.
2 Activity Status LEDs
The top row of Status LEDs, labelled Activity, show
the activity of the related ports:
3 Link/Duplex Status LEDs
The second, third, and fourth row of Status LEDs,
labelled 10, 100, 1000, show the link or speed
status of the related ports:
F
EATURES
OF
THE
B
ASELINE
10/100/1000 S
WITCH
Front Panel
Rear Panel
!
Status Meaning
Yellow Packet(s) received or transmitted on this port.
Off No packet(s) received or transmitted on this port.
Speed Status Meaning
1000 Off Not linked at 1000BASE-T
Green Linked at 1000BASE-T, full duplex
100 Off Not linked at 100BASE-TX
Green Linked at 100BASE-TX, full duplex
Yellow Linked at 100BASE-TX, half duplex
10 Off Not linked at 10BASE-T
Green Linked at 10BASE-T, full duplex
Yellow Linked at 10BASE-T, half duplex
2
4Power LED
The Power LED indicate the status of the unit's internal
power as follows:
Rear Panel Connections
5 Power Supply
The Baseline 10/100/1000 Switch 6-Port automatically
adjusts to the supply voltage. Only use the power cord
that is supplied with the unit.
6 Socket for Redundant Power System (RPS)
Connect a 3Com SuperStack 3 Advanced RPS (3C16070,
3C16071, 3C16071A, or 3C16071B) only to this socket.
An appropriate power module and cable is required. The
connector on the Baseline 10/100/1000 Switch 6-Port
requires a Type 2A module. For details, follow the
installation instructions in the guides that accompany the
Advanced RPS and the power module.
Positioning the Switch
When deciding where to position the Baseline
10/100/1000 Switch 6-Port ensure:
It is accessible and cables can be connected easily.
Cabling is away from sources of electrical noise.
These include lift shafts, microwave ovens, and air
conditioning units. Electromagnetic fields can inter-
fere with the signals on copper cabling and intro-
duce errors, therefore slowing down your network.
Water or moisture cannot enter the case of the unit.
Air flow around the unit and through the vents in the
side of the case is not restricted (3Com recommend
that you provide a minimum of 25 mm (1 in.) clear-
ance).
The air is as free from dust as possible.
Temperature operating limits are not likely to be
exceeded. It is recommended that the unit is installed
in a clean, air conditioned environment.
It is always good practice to wear an anti-static wrist
strap when installing network equipment, connected to
a ground point. If one is not available, try to keep in
contact with a grounded rack and avoid touching the
unit's ports and connectors, if possible. Static discharge
can cause reliability problems in your equipment.
Rack Mounting or Free Standing
This unit can be mounted in a 19-inch equipment rack
using the Mounting Kit. Refer to
Mounting Kit
Instructions on page 4. It can also be free standing. Do
not place objects on top of the unit or stack.
The unit is supplied with four self-adhesive rubber pads.
If the unit is to be part of a free standing stack, apply
the pads to each marked corner area on the underside
of the unit. Place the unit on top of the lower unit,
ensuring that the pads locate with the recesses of the
lower unit.
You do not need to apply the pads if you intend to rack
mount the unit.
CAUTION: If installing the Baseline 10/100/1000 Switch
6-Port in a free standing stack of different size
SuperStack II or SuperStack 3 units, the smaller units
must be installed above the larger ones. Do not build a
free standing stack of more than six units.
Connecting to a Network Device
Follow these guidelines to connect a device to the
Baseline 10/100/1000 Switch 6-Port:
Use Category 5 unshielded or shielded (screened) 100
Ohm TP cable (or Category 3 cable for a 10 Mbps
connection).
The maximum length of cable for each connection is
100m (328ft).
Connect one end of the cable to an RJ-45 port on
the Baseline 10/100/1000 Switch 6-Port, and the
other end to the appropriate RJ-45 port on the con-
necting device.
Power Supply
Power problems can be the cause of serious failures and
downtime in your network. Ensure that the power input
to your system is clean and free from sags and surges to
avoid unforeseen network outages. 3Com recommends
that you install power conditioning, especially in areas
prone to black outs, power dips and electrical storms.
The unit is intended to be grounded. Ensure it is
connected to earth ground during normal use. Installing
proper grounding helps to avoid damage from lightning
and power surges.
Powering Up
Use the following sequence to power up the Baseline
10/100/1000 Switch 6-Port:
1 Check the network connections and cables.
2 Connect the power supply cable to the appropriate
power socket on the rear panel of the unit; see refer-
ence 5 or 6 in Features of the Baseline 10/100/1000
Switch.
3 Connect the plug to the power supply outlet socket and
switch on the power supply at the socket. If you are
using the Advanced Redundant Power System, ensure it
is powered on.
When the switch is powered on, the Power LED lights
green. If it does not, see reference 4 in Features of the
Baseline 10/100/1000 Switch.
Status Meaning
Off Unit power rails faulty
Green Normal operation; all power rails functional
Yellow Unit shutdown due to excessive temperature. Refer to Prob-
lem Solving on page 4
.
I
NSTALLING
THE
S
WITCH
!
3
Introduction
The Baseline 10/100/1000 Switch 6-Port is supplied with
two mounting brackets and four screws. These are used
for rack mounting the unit. When mounting the unit,
you should take note of the guidelines given in
Positioning the Switch on page 3.
Rack Mounting the Units
The Baseline 10/100/1000 Switch 6-Port is 1U high and
will fit a standard 19-inch rack.
CAUTION: Disconnect all cables from the unit before
continuing. Remove the self-adhesive pads from the
underside of unit, if already fitted.
1
Place the unit the right way up on a hard, flat surface
with the front facing towards you.
2
Locate a mounting bracket over the mounting holes on
one side of the unit (refer to the figure following step
6).
3
Insert the two screws supplied in the mounting kit and
fully tighten with a suitable screwdriver.
4
Repeat the two previous steps for the other side of the
unit.
5
Insert the unit into the 19-inch rack and secure with
suitable screws (not provided).
6
Reconnect all cables.
At frequent intervals you should visually check the
Baseline 10/100/1000 Switch 6-Port. Regular checks can
give you an early warning of a possible failure; any
problems can then be attended to when there will be
least effect on users.
Check that all external cabling connections are secure
and that no cables are pulled taut.
Refer to the information about LEDs given earlier in this
guide to see if the problem can be identified and
rectified. Here are some common problems that can
occur:
Power LED is yellow.
The temperature of the unit has
exceeded reliable operating limits. Do the following:
1
Ensure all fans are operating correctly.
2
Check the temperature of the room in which the unit is
located. The room temperature must not exceed 50° C
(122° F).
3
Disconnect the mains supply and re-connect.
Activity Status LED not lit for a port that has a
connection.
There is a problem with this connection.
Check that:
The device being connected to is powered on and
operating correctly.
The cable is connected at both ends.
You are using a TP cable that is not damaged.
If the connection is to a workstation, that the work-
stations network interface is installed and configured
correctly.
All Activity LEDs appear to be lit continually.
There
may be broadcast storms on the network. Remove port
connections one at a time, waiting a few seconds
between each port. If the LEDs go off after removing a
port connection, the device that was connected to that
port is introducing an excessive amount of broadcast
frames to the network (some pieces of network
equipment operate by sending out broadcast frames
regularly). Refer to the documentation that accompanies
the device for information on disabling the broadcast
operation.
If the problem persists and the unit still does not operate
successfully, contact your supplier with the following
information before returning the unit:
Product number and serial number (printed on a label
supplied with the unit)
A brief description of the fault
Please read the following safety information
carefully before installing the Baseline 10/100/1000
Switch 6-Port.
WARNING:
Installation and removal of the unit must be carried out
by qualified personnel only.
If installing the Switch unit in a stack with SuperStack II or SuperStack 3
Hub units, the Baseline 10/100/1000 Switch 6-Port unit must be installed
below the narrower Hub units.
The unit must be connected to an earthed (grounded) outlet to comply with
international safety standards.
Do not connect the unit to an A.C. outlet (power supply) without an earth
(ground) connection.
M
OUNTING
K
IT
I
NSTRUCTIONS
P
ROBLEM
S
OLVING
S
AFETY
I
NFORMATION
4
The appliance coupler (the connector to the unit and not the wall plug)
must have a configuration for mating with an EN60320/IEC320 appliance
inlet.
The socket outlet must be near to the unit and easily accessible. You can
only remove power from the unit by disconnecting the power cord from the
outlet.
This unit operates under SELV (Safety Extra Low Voltage) conditions
according to IEC 60. The conditions are only maintained if the equipment to
which it is connected also operates under SELV conditions.
Only connect an
Advanced Redundant Power System (3C16070, 3C16071
or 3C16071A)
or
Redundant Power System (3C565047)
to the
Redundant
Power System
socket.
France and Peru only
This unit cannot be powered from IT
supplies. If your supplies are of IT type, this
unit must be powered by 230V (2P+T) via an isolation transformer ratio 1:1, with
the secondary connection point labelled Neutral, connected directly to earth
(ground).
Impédance à la terre
Power Cord Set
This must be approved for the country where it will be used. e.g.
Veuillez lire à fond l'information de la sécurité
suivante avant d'installer le Baseline 10/100/1000
Switch 6-Port.
AVERTISSEMENT:
Linstallation et la dépose de ce groupe doivent
être confiés à un personnel qualifié.
Si vous entassez lunité Switch avec les unités SuperStack II Hub, lunité
Baseline 10/100/1000 Switch 6-Port doit être installée en dessous des unités
Hub plus étroites.
Ne branchez pas votre appareil sur une prise secteur (alimentation
électrique) lorsqu'il n'y a pas de connexion de mise à la terre (mise à la
masse).
Vous devez raccorder ce groupe à une sortie mise à la terre (mise à la
masse) afin de respecter les normes internationales de sécurité.
Le coupleur dappareil (le connecteur du groupe et non pas la prise murale)
doit respecter une configuration qui permet un branchement sur une entrée
dappareil EN60320/IEC 320.
La prise secteur doit se trouver à proximité de lappareil et son accès doit
être facile. Vous ne pouvez mettre lappareil hors circuit quen débranchant
son cordon électrique au niveau de cette prise.
Lappareil fonctionne à une tension extrêmement basse de sécurité qui est
conforme à la norme IEC60950. Ces conditions ne sont maintenues que si
l’équipement auquel il est raccordé fonctionne dans les mêmes conditions.
Branchez uniquement un
Advanced Redundant Power System (3C16070,
3C16071 ou 3C16071A)
ou un
Redundant Power System (3C565047)
sur la
prise femelle du
Redundant Power System
.
France et Pérou uniquement:
Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si vos
alimentations sont du type impédance à la terre, ce groupe doit être alimenté par
une tension de 230 V (2 P+T) par le biais dun transformateur disolement à rapport
1:1, avec un point secondaire de connexion portant lappellation Neutre et avec
raccordement direct à la terre (masse).
Cordon électrique
Il doit être agréé dans le pays dutilisation.
Bitte unbedingt vor dem Einbauen des Baseline
10/100/1000 Switch 6-Port Einheit die folgenden
Sicherheitsanweisungen durchlesen.
WARNUNG:
Die Installation und der Ausbau des Geräts darf nur
durch Fachpersonal erfolgen.
Wenn die Baseline 10/100/1000 Switch 6-Port Einheit in einer Stapel mit anderen
SuperStack II Hub Einheiten eingebaut werden soll, muß die Baseline 10/100/1000
Switch 6-Port Einheit unter die schmaleren Hub Einheiten eingebaut werden.
Das Gerät nicht an eine Wechselstromsteckdose anschließen, die nicht
geerdet ist.
Das Gerät muß an eine geerdete Steckdose angeschlossen werden, die die
internationalen Sicherheitsnormen erfüllt.
Der Gerätestecker (der Anschluß an das Gerät, nicht der
Wandsteckdosenstecker) muß eine passende Konfiguration für einen
Geräteeingang gemäß EN60320/IEC320 haben.
Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein.
Die Stromversorgung des Geräts kann nur durch Herausziehen des
Gerätenetzkabels aus der Netzsteckdose unterbrochen werden.
Der Betrieb dieses Geräts erfolgt unter den SELV-Bedingungen
(Sicherheitskleinstspannung) gemäß IEC 60. Diese Bedingungen sind nur
gegeben, wenn auch die an das Gerät angeschlossenen Geräte unter
SELV-Bedingungen betrieben werden.
Nur ein
Advanced Redundant Power System (3C16070, 3C16071
oder
3C16071A)
oder
Redundant Power System (3C565047)
an den
Redundant
Power System
Anschluß anschließen.
U.S.A. and
Canada
The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
No. 18 AWG
Type SV or SJ
3-conductor
The cord set must have a rated current capacity of at least
10A.
The attachment plug must be an earth-grounding type with a
NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A, 250V)
configuration.
Denmark
The supply plug must comply with Section 107-2-D1, Standard
DK2-1a or DK2-5a.
Switzerland
The supply plug must comply with SEV/ASE 1011.
UK
The supply plug must comply with BS1363 (3-pin 13-amp) and
be fitted with a 5A fuse which complies with BS1362.
The mains cord must be <HAR> or <BASEC> marked and be
of type HO3VVF3GO.75 (minimum).
Europe
The supply plug must comply with CEE7/7 (SCHUKO)
The mains cord must be <HAR> or <BASEC> marked and be
of type HO3VVF3GO.75 (minimum).
L
INFORMATION
DE
S
ÉCURITÉ
I
MPORTANTE
Etats-Unis et
Canada:
Le cordon doit avoir reçu lhomologation des UL et un
certificat de la CSA.
Le cordon souple doit respecter, à titre minimum, les
spécifications suivantes:
calibre 18 AWG
type SV ou SJ
à 3 conducteurs
Le cordon doit être en mesure dacheminer un courant
nominal dau moins 10 A.
La prise femelle de branchement doit être du type à mise à la
terre (mise à la masse) et respecter la configuration NEMA
5-15P (15 A, 125 V) ou NEMA 6-15P (15 A, 250 V).
Danemark:
La prise mâle dalimentation doit respecter la section 107-2 D1
de la norme DK2 1a ou DK2 5a.
Suisse:
La prise mâle dalimentation doit respecter la norme SEV/ASE
1011.
Europe
La prise secteur doit être conforme aux normes CEE 7/7
(SCHUKO)
LE cordon secteur doit porter la mention <HAR> ou <BASEC>
et doit être de type HO3VVF3GO.75 (minimum).
W
ICHTIGE
S
ICHERHEITSINFORMATIONEN
Stromkabel
. Dies muss von dem Land, in dem es benutzt wird geprüft werden:
Schweiz
Dieser Stromstecker muß die SEV/ASE 1011Bestimmungen
einhalten.
Europe
Das Netzkabel muß vom Typ HO3VVF3GO.75
(Mindestanforderung) sein und die Aufschrift <HAR> oder
<BASEC> tragen.
Der Netzstecker muß die Norm CEE 7/7 erfüllen (SCHUKO).
5
Related Standards
The SuperStack 3 Baseline 10/100/1000 Switch 6-Port
10BASE-T/100BASE-TX/1000BASE-T has been designed
to the following standards:
Environmental
Physical
Electrical
This warranty applies to customers located in the United States, Australia, Canada
(except Quebec), Ireland, New Zealand, U.K., and other English language countries,
and countries for which a translation into the local language is not provided.
SuperStack 3 Baseline 10/100/1000 Switch 6-Port 10BASE-T/100BASE-TX/
1000BASE-T
HARDWARE:
3Com warrants to the end user ("Customer") that this hardware
product will be free from defects in workmanship and materials, under normal use
and service, for the following length of time from the date of purchase from 3Com
or its authorized reseller:
Lifetime, for as long as the original Customer owns the product (not transferable to
a subsequent end user)
3Com's sole obligation under this express warranty shall be, at 3Com's option and
expense, to repair the defective product or part, deliver to Customer an equivalent
product or part to replace the defective item, or if neither of the two foregoing
options is reasonably available, 3Com may, in its sole discretion, refund to Customer
the purchase price paid for the defective product. All products that are replaced will
become the property of 3Com. Replacement products or parts may be new or
reconditioned. 3Com warrants any replaced or repaired product or part for ninety
(90) days from shipment, or the remainder of the initial warranty period, whichever
is longer.
SOFTWARE:
3Com warrants to Customer that each software program licensed
from it, except as noted below, will perform in substantial conformance to its
program specifications, for a period of ninety (90) days from the date of purchase
from 3Com or its authorized reseller. 3Com warrants the media containing software
against failure during the warranty period. No updates are provided, unless
specifically included in the Included Services section. 3Com's sole obligation under
this express warranty shall be, at 3Com's option and expense, to refund the
purchase price paid by Customer for any defective software product, or to replace
any defective media with software which substantially conforms to applicable 3Com
published specifications. Customer assumes responsibility for the selection of the
appropriate applications program and associated reference materials. 3Com makes
no warranty or representation that its software products will meet Customer's
requirements or work in combination with any hardware or applications software
products provided by third parties, that the operation of the software products will
be uninterrupted or error free, or that all defects in the software products will be
corrected. For any third party products listed in the 3Com software product
documentation or specifications as being compatible, 3Com will make reasonable
efforts to provide compatibility, except where the non-compatibility is caused by a
"bug" or defect in the third party's product or from use of the software product
not in accordance with 3Com's published specifications or user manual.
THIS 3COM PRODUCT MAY INCLUDE OR BE BUNDLED WITH (1) THIRD PARTY
SOFTWARE, OR (2) 3COM SOFTWARE THAT IS LICENSED "AS IS", THE USE OF
WHICH IS GOVERNED BY A SEPARATE END USER LICENSE AGREEMENT. THIS
3COM WARRANTY DOES NOT APPLY TO SUCH THIRD PARTY SOFTWARE OR 3COM
SOFTWARE LICENSED "AS IS". FOR THE APPLICABLE WARRANTY, PLEASE REFER TO
THE END USER LICENSE AGREEMENT GOVERNING THE USE OF SUCH SOFTWARE
OR THE ACCOMPANYING DOCUMENTATION RELATING TO SUCH SOFTWARE.
YEAR 2000 WARRANTY:
In addition to the Hardware Warranty and Software
Warranty stated above, 3Com warrants that each product sold or licensed to
Customer on and after January 1, 1998 that is date sensitive will continue
performing properly with regard to such date data on and after January 1, 2000,
provided that all other products used by Customer in connection or combination
with the 3Com product, including hardware, software, and firmware, accurately
exchange date data with the 3Com product, with the exception of those products
identified at 3Com's Web site, http://www.3com.com/products/yr2000.html, as not
meeting this standard. If it appears that any product that is stated to meet this
standard does not perform properly with regard to such date data on and after
January 1, 2000, and Customer notifies 3Com within ninety (90) days after
purchase of the product from 3Com or its authorized reseller, 3Com shall, at its
option and expense, provide a software update which would effect the proper
performance of such product, repair such product, deliver to Customer an
equivalent product to replace such product, or if none of the foregoing is feasible,
refund to Customer the purchase price paid for such product.
Any software update or replaced or repaired product will carry a Year 2000
Warranty for ninety (90) days after purchase.
OBTAINING WARRANTY SERVICE:
Customer must contact a 3Com Corporate
Service Center or an Authorized 3Com Service Center within the applicable
warranty period to obtain warranty service authorization. Dated proof of purchase
from 3Com or its authorized reseller may be required. Products returned to 3Com's
Corporate Service Center must be pre-authorized by 3Com with a User Service
Order (USO) number (or a Return Material Authorization (RMA) number or a Service
Repair Order (SRO) number, whichever was issued) marked on the outside of the
package, and sent prepaid and packaged appropriately for safe shipment, and it is
recommended that they be insured or sent by a method that provides for tracking
of the package. Responsibility for loss or damage does not transfer to 3Com until
the returned item is received by 3Com. The repaired or replaced item will be
shipped to Customer, at 3Com's expense, not later than thirty (30) days after 3Com
receives the defective product, and 3Com will retain risk of loss or damage until the
item is delivered to Customer.
3Com shall not be responsible for any software, firmware, information, or memory
data of Customer contained in, stored on, or integrated with any products returned
to 3Com for repair, whether under warranty or not.
Dead- or Defective-on-Arrival.
In the event a product completely fails to function
or exhibits a defect in materials or workmanship within the first forty-eight (48)
hours of installation but no later than thirty (30) days after the date of purchase,
and this is verified by 3Com, it will be considered dead- or defective-on-arrival
(DOA) and a replacement shall be provided prior to 3Com receiving the defective
product, but only if Customer provides a purchase order number, credit card
number, or other method of payment acceptable to 3Com, to be used if 3Com
needs to charge Customer for the replacement, as explained below. The
replacement product will normally be shipped not later than three (3) business days
after 3Com's verification of the DOA product, but may be delayed due to export or
import procedures. The shipment of a replacement product prior to 3Com receiving
the defective product is subject to local legal requirements and may not be available
in all locations. When such a replacement is provided and Customer fails to return
the original product to 3Com within fifteen (15) days after shipment of the
replacement, 3Com will charge Customer for the replacement product, at list price.
Shipment of a Replacement Prior to 3Com Receiving the Defective Product
is
provided for five (5) years, after which time it may be available for a specified fee,
but in either case only if Customer provides a purchase order number, credit card
number, or other method of payment acceptable to 3Com, to be used if 3Com
needs to charge Customer for the replacement, as explained below. 3Com will
make commercially reasonable efforts to ship the replacement product not later
than five (5) business days after receiving the request for a replacement, but may
be delayed due to product availability or export or import procedures. The shipment
of a replacement product prior to 3Com receiving the defective product is subject
to local legal requirements and may not be available in all locations. When such a
replacement is provided and Customer fails to return the original product to 3Com
within fifteen (15) days after shipment of the replacement, 3Com will charge
Customer for the replacement, at list price. This replacement prior to 3Com
receiving the defective product is different from the fee-based Advance Hardware
Replacement Service, which is available as a contracted service offering.
INCLUDED SERVICES:
3Com's Electronic Support Services,
available at no
charge, include 3Com Knowledgebase, information on known bugs,
documentation, release notes, and publicly available software and firmware
upgrades. 3Com reserves the right to modify or cancel this offering at any time,
without advance notice.
Telephone Technical Support,
with coverage for basic troubleshooting only, will
be provided at no additional charge for 12 months from the date of purchase, on a
commercially reasonable efforts basis. Telephone support is provided by 3Com only
T
ECHNICAL
I
NFORMATION
Functional
ISO 8802-3, IEEE 802.3 (Ethernet), IEEE 802.3u (Fast
Ethernet), IEEE 802.3ab (Gigabit Ethernet), IEEE 802.3x
(Flow Control), IEEE 802.1D (Bridging)
Safety
UL 1950, EN 60950, CSA 22.2 #950, IEC 60950
EMC Emissions
EN 55022 Class A, FCC Part 15 Subpart B Class A,
ICES-003 Class A, VCCI Class A, AS/NZS 3548 Class A,
CNS 13438 Class A
Immunity
EN 55024
Operating Temperature
050°C (32122 °F)
Humidity
1090% (non-condensing)
Standard
EN 60068 (IEC 68)various parts
Width
440 mm (17.3 in.)
Depth
247.5 mm (9.7 in.)
Height
43.6 mm (1.7 in.) or 1U
Weight
2.85 kg (6.3 lb)
Mounting
Free standing, or 19-inch rack mounted using the
mounting kit supplied
Power Inlet
IEC 320
AC Line Frequency
50/60 Hz
Input Voltage
100240 VAC
Current Rating
3 A (maximum)
Maximum Power
Consumption
75 W
Maximum Power
Dissipation
256 BTU/hr
3C
OM
L
IMITED
W
ARRANTY
6
if Customer purchased this product directly from 3Com, or if Customer's reseller is
unable to provide telephone support. To qualify for this telephone technical
support, Customer must register on the 3Com Web site at
http://support.3Com.com/index.htm, and state the date of purchase, product
number, and serial number. 3Com's response to a request for telephone technical
support will be in the form of a return call from a 3Com representative by close of
business the following business day, defined as 9 a.m. to 5 p.m., local time,
Monday through Friday, excluding local holidays. Please refer to the Technical
Support appendix in the User Guide for telephone numbers.
Software Updates,
All software and firmware upgrades and the latest code for
this product downloaded through the 3Com Software Library.
WARRANTIES EXCLUSIVE:
IF A 3COM PRODUCT DOES NOT OPERATE AS
WARRANTED ABOVE, CUSTOMER'S SOLE REMEDY FOR BREACH OF THAT
WARRANTY SHALL BE REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE
PRICE PAID, AT 3COM'S OPTION. TO THE FULL EXTENT ALLOWED BY LAW, THE
FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF
ALL OTHER WARRANTIES, TERMS, OR CONDITIONS, EXPRESS OR IMPLIED, EITHER
IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING
WARRANTIES, TERMS, OR CONDITIONS OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE, SATISFACTORY QUALITY, CORRESPONDENCE WITH
DESCRIPTION, AND NON-INFRINGEMENT, ALL OF WHICH ARE EXPRESSLY
DISCLAIMED. 3COM NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO
ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE,
INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS.
3COM SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND
EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT OR MALFUNCTION IN THE
PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER'S OR ANY THIRD
PERSON'S MISUSE, NEGLECT, IMPROPER INSTALLATION OR TESTING,
UNAUTHORIZED ATTEMPTS TO OPEN, REPAIR OR MODIFY THE PRODUCT, OR ANY
OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT,
FIRE, LIGHTNING, POWER CUTS OR OUTAGES, OTHER HAZARDS, OR ACTS OF
GOD.
LIMITATION OF LIABILITY:
TO THE FULL EXTENT ALLOWED BY LAW, 3COM ALSO
EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY, WHETHER BASED IN
CONTRACT OR TORT (INCLUDING NEGLIGENCE), FOR INCIDENTAL,
CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR
FOR LOSS OF REVENUE OR PROFITS, LOSS OF BUSINESS, LOSS OF INFORMATION
OR DATA, OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH
THE SALE, INSTALLATION, MAINTENANCE, USE, PERFORMANCE, FAILURE, OR
INTERRUPTION OF ITS PRODUCTS, EVEN IF 3COM OR ITS AUTHORIZED RESELLER
HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, AND LIMITS ITS
LIABILITY TO REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID,
AT 3COM'S OPTION. THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE
AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL
PURPOSE.
DISCLAIMER:
Some countries, states, or provinces do not allow the exclusion or
limitation of implied warranties or the limitation of incidental or consequential
damages for certain products supplied to consumers, or the limitation of liability for
personal injury, so the above limitations and exclusions may be limited in their
application to you. When the implied warranties are not allowed to be excluded in
their entirety, they will be limited to the duration of the applicable written warranty.
This warranty gives you specific legal rights which may vary depending on local law.
GOVERNING LAW:
This Limited Warranty shall be governed by the laws of the
State of California, U.S.A., and by the laws of the United States, excluding their
conflicts of laws principles. The United Nations Convention on Contracts for the
International Sale of Goods is hereby excluded in its entirety from application to this
Limited Warranty.
3Com Corporation
5400 Bayfront Plaza
P.O. Box 58145
Santa Clara, CA 95052-8145
(408) 326-5000
November, 2000
3Com reserves the right to modify or cancel this offering at any time, without
advance notice. This offering is not available where prohibited or restricted by law.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference to radio
communications, in which case the user will be required to correct the interference
at their own expense.
Information To The User
If this equipment does cause interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
Reorient the receiving antenna.
Relocate the equipment with respect to the receiver.
Move the equipment away from the receiver.
Plug the equipment into a different outlet so that equipment and receiver are on
different branch circuits.
If necessary, the user should consult the dealer or an experienced radio/television
technician for additional suggestions. The user may find the following booklet
prepared by the Federal Communications Commission helpful:
How to Identify and Resolve Radio-TV Interference Problems
This booklet is available from the U.S. Government Printing Office, Washington,
DC 20402, Stock No. 004-000-00345-4.
In order to meet FCC emissions limits, this equipment must be used only with
cables which comply with IEEE 802.3.
CE Statement (Europe)
This product complies with the European Low Voltage Directive 73/23/EEC and EMC
Directive 89/336/EEC as amended by European Directive 93/68/EEC/.
CSA Statement
This Class A digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement
sur le matériel brouilleur du Canada.
VCCI Statement
BSMI Statement
For further information on obtaining support, refer to
the Technical Support information in the User Guide that
accompanies the Switch, or visit our Support Web site:
http://www.support.3com.com
Alternatively, the following numbers may be used for
technical support:
R
EGULATORY
N
OTICES
T
ECHNICAL
S
UPPORT
Country Telephone Number Country Telephone Number Country Telephone Number
Asia, Pacific Rim
Australia
Hong Kong
India
Indonesia
Japan
Malaysia
New Zealand
Pakistan
Philippines
1 800 678 515
800 933 486
+61 2 9937 5085
001 800 61 009
0031 61 6439
1800 801 777
0800 446 398
+61 2 9937 5085
1235 61 266 2602
P.R. of China
Singapore
S. Korea:
From anywhere in
S. Korea:
From Seoul:
Taiwan, R.O.C.
Thailand
10800 61 00137 or
021 6350 1590
800 6161 463
00798 611 2230
(0)2 3455 6455
0080 611 261
001 800 611 2000
Latin America
Argentina
Brazil
Chile
Colombia
Mexico
Peru
Puerto Rico
Venezuela
AT&T +800 666 5065
0800 13 3266
1230 020 0645
98012 2127
01 800 CARE (01 800 2273)
AT&T +800 666 5065
800 666 5065
AT&T +800 666 5065
7
© 3Com Technologies, 2000.
All rights reserved. No part of this
documentation may be reproduced in any form or by any means or used
to make any derivative work (such as translation, transformation, or
adaptation) without permission from 3Com Technologies.
3Com Technologies reserves the right to revise this documentation and
to make changes in content from time to time without obligation on the
part of 3Com Technologies to provide notification of such revision or
change.
3Com Technologies provides this documentation without warranty of any
kind, either implied or expressed, including, but not limited to, the
implied warranties of merchantability and fitness for a particular purpose.
3Com may make improvements or changes in the product(s) and/or the
program(s) described in this documentation at any time.
UNITED STATES GOVERNMENT LEGENDS:
If you are a United States government agency, then this documentation
and the software described herein are provided to you subject to the
following restricted rights:
For units of the Department of Defense:
Restricted Rights Legend: Use, duplication or disclosure by the
Government is subject to restrictions as set forth in subparagraph (c) (1)
(ii) for restricted Rights in Technical Data and Computer Software clause
at 48 C.F.R. 52.227-7013. 3Com Centre, Boundary Way, Maylands Park
South, Hemel Hempstead, Herts, HP2 7YU, U.K.
For civilian agencies:
Restricted Rights Legend: Use, reproduction or disclosure is subject to
restrictions set forth in subparagraph (a) through (d) of the Commercial
Computer Software - Restricted Rights Clause at 48 C.F.R. 52.227-19 and
the limitations set forth in 3Com Corporations standard commercial
agreement for the software. Unpublished rights reserved under the
copyright laws of the United States.
If there is any software on removable media described in this
documentation, it is furnished under a license agreement included with
the product as a separate document, in the hard copy documentation, or
on the removable media in a directory file named LICENSE.TXT. If you are
unable to locate a copy, please contact 3Com and a copy will be
provided to you.
Unless otherwise indicated, 3Com registered trademarks are registered in
the United States and may or may not be registered in other countries.
3Com and SuperStack are registered trademarks of 3Com Corporation.
Other brand and product names may be registered trademarks or
trademarks of their respective holders.
General Environmental Statement
It is the policy of 3Com Corporation to be environmentally-friendly in all
operations. To uphold our policy, we are committed to:
Establishing environmental performance standards that comply
with national legislation and regulations
Conserving energy, materials and natural resources in all
operations
Reducing the waste generated by all operations
Ensuring that all waste conforms to recognized environmental
standards
Maximizing the recyclable and reusable content of all products
Ensuring that all products can be recycled, reused and disposed
of safely
Ensuring that all products are labelled according to recognized
environmental standards
Improving our environmental record on a continual basis
End Of Life Statement
3Com processes allow for the recovery, reclamation and safe disposal of
all end-of-life electronic components.
Regulated Materials Statement
3Com products do not contain any hazardous or ozone-depleting
material.
Environmental Statement about the Documentation
The documentation for this product is printed on paper that comes from
sustainable, managed forests; it is fully biodegradable and recyclable, and
is completely chlorine-free. The varnish is environmentally-friendly, and
the inks are vegetable-based with a low heavy-metal content.
Europe
From anywhere in Europe,
call:
+31 (0)30 6029900 phone
+31 (0)30 6054396 fax
Europe, South Africa, and Middle East
From the following countries, you may use the following toll-free numbers:
Austria
Belgium
Denmark
Finland
France
Germany
0800 297468
0800 71429
800 17309
0800 113153
0800 917959
0800 1821502
Hungary
Ireland
Israel
Italy
Netherlands
Norway
00800 12813
1800 553117
1800 9453794
1678 79489
0800 0227788
800 11376
Poland
Portugal
South Africa
Spain
Sweden
Switzerland
U.K.
00800 3111206
0800 831416
0800 995014
900 983125
020 795482
0800 55 3072
0800 966197
North America
1 800 876-3266
Country Telephone Number Country Telephone Number Country Telephone Number
L
EGAL
N
OTICES
E
NVIRONMENTAL
S
TATEMENTS
8
Part Number: DUA1646-8AAA02
Published: November 2000
Product Registration
You can now register your SuperStack 3 Baseline 10/100/1000 Switch on the 3Com web site:
http://support.3com.com/warrantyregistration/register.pl
Documentation Feedback
Your suggestions are very important to us. They will help make our documentation more useful to you. Please e-mail comments
about this document to 3Com at:
Please include the following information when commenting: the document title, part number, and page number, if appropriate.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

3com SS3 BASELINE 100/1000 SW 6-PORT Manuel utilisateur

Catégorie
Commutateurs réseau
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues