Haier HWF05XCK-E Le manuel du propriétaire

Taper
Le manuel du propriétaire
No.0010518324
ROOM AIR CONDITIONER
Use & Care Guide
ACONDICIONADOR DE AIRE PARA HABITACIÓN
Manual de Uso y Cuidado
CLIMATISEUR DE PIÈCE
Guide d’utilisation et d’entretien
Model:
HWF05XCK HWF05XCK-L
HWF05XCK-T HWF05XCK-E
For questions about features, operation/performance, parts,
accessories or service call: 1-877-337-3639
Si tiene preguntas respecto a las características, funcionamiento,
rendimiento, partes, accesorios o servicio técnico,
llame al: 1-877-337-3639
Au Canada, pour assistance, installation ou service,
composez le : 1-877-337-3639
TABLE OF CONTENTS
ÍNDICE
TABLE DES MATIÈRES
AIR CONDITIONER SAFETY ........................................................3
INSTALLATION REQUIREMENTS.................................................3
Tools and Parts ............................................................................3
Location Requirements ...............................................................4
Electrical Requirements ...............................................................4
INSTALLATION INSTRUCTIONS...................................................5
Unpack the Air Conditioner..........................................................5
Prepare Air Conditioner for Installation........................................5
Prepare Window for Installation...................................................6
Position Air Conditioner ..............................................................7
Complete Installation ..................................................................8
AIR CONDITIONER USE...............................................................9
Starting Your Air Conditioner .......................................................9
Changing Air Direction ................................................................ 9
Normal Sounds............................................................................ 9
AIR CONDITIONER CARE ...........................................................10
Cleaning the Air Filter .................................................................10
Cleaning the Front Panel.............................................................10
Annual Maintenance....................................................................10
TROUBLE SHOOTING ..................................................................10
ASSISTANCE OR SERVICE..........................................................12
In the U.S.A. ...............................................................................12
In Canada ...................................................................................12
WARRANTY ..................................................................................13
SEGURIDAD DEL ACONDICIONADOR DE AIRE......................14
REQUISITOS DE INSTALACIÓN.................................................14
Herramientas y piezas................................................................14
Requisitos de ubicación.............................................................15
Requisitos eléctricos..................................................................15
INSTRUCCIONES DE INSTALACIÓN.........................................16
Desempaque el acondicionador de aire....................................16
Prepare el acondicionador de aire para la instalación ..............17
Preparación de la ventana para la instalación............................17
Coloque el acondicionador de aire en su lugar..........................18
Complete la instalación.............................................................. 19
CÓMO USAR EL ACONDICIONADOR DE AIRE .......................20
Cómo poner en marcha su acondicionador de aire...................20
Cómo cambiar la dirección del aire ........................................... 20
Sonidos normales.......................................................................20
CUIDADO DE SU ACONDICIONADOR DE AIRE.......................21
Limpieza del filtro de aire ...........................................................21
Limpieza del panel frontal ..........................................................21
Mantenimiento anual..................................................................21
SOLUCIÓN DE PROBLEMAS......................................................21
AYUDA O SERVICIO TÉCNICO...................................................23
En los EE.UU. .............................................................................23
En los CANADÁ. .............................................................................23
GARANTÍA.....................................................................................24
SÉCURITÉ DU CLIMATISEUR ...................................................25
EXIGENCES D’INSTALLATION...................................................25
Outillage et pièces......................................................................25
Exigences d’emplacement.........................................................26
Spécifications électriques .........................................................26
INSTRUCTIONS D’INSTALLATION ............................................27
Déballage du climatiseur............................................................27
Préparer le climatiseur pour l’installation...................................28
Préparation de la fenêtre pour l’installation ...............................29
Positionnement du climatiseur...................................................29
Achever l’installation ..................................................................30
UTILISATION DU CLIMATISEUR................................................31
Mise en marche du climatiseur...................................................31
Changement de direction de l’air.................................................31
Sons normaux ............................................................................31
ENTRETIEN DU CLIMATISEUR...................................................32
Nettoyage du filtre à air ..............................................................32
Nettoyage du panneau avant.....................................................32
Entretien annuel..........................................................................32
DÉPANNAGE.................................................................................32
ASSISTANCE OU SERVICE.........................................................34
Aux États-Unis............................................................................34
Au Canada..................................................................................34
GARANTIE.....................................................................................
35
2
AIR CONDITIONER SAFETY
INSTALLATION REQUIREMENTS
Tools and Parts
You can be killed or seriously injured if you don't immediately
You can be killed or seriously injured if you don't follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
IMPORTANT SAFETY INSTRUCTIONS
WARNING:
To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic precautions:
SAVE THESE INSTRUCTIONS
Unplug air conditioner before servicing.
Use two or more people to move and install air conditioner.
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
A
B
C
D
EFG
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed here.
Tools needed
A. Top channel
B. Foam seal
C. Window lock bracket (3)
D. ⁄” screws (3)
E. ⁄” screws (7)
F. Side curtains (2)
G. Side curtain frames (2)
Parts supplied:
Check that all parts are included in parts package.
Phillips head screwdriver
Flat-blade screwdriver
Scissors
Level
Socket wrench and sockets
Tape measure
Cordless drill and 1/8” bit
Pencil
Pliers
Adjustable wrench
3
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Check the location where the air conditioner will be installed.
Make sure you have everything necessary for correct installation.
The location should provide:
Grounded electrical outlet within 6 ft (183 cm) of where the
power cord exits the air conditioner.
NOTE: Do not use an extension cord.
Free movement of air in room to be cooled.
A large enough opening for the air conditioner. Installation
parts are supplied for double-hung windows.
Adequate wall support for weight of air conditioner. Air
conditioner weighs 36 lbs to 42 lbs (16.3 kg to 19.1 kg).
NOTE: Cabinet louvers must not be obstructed. Air must be able
to pass freely through the cabinet louvers.
The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number
label is located either on the side or back of the air conditioner
cabinet or behind the front grille.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
This air conditioner must be grounded. This air conditioner is
equipped with a power supply cord having a 3 prong grounding
plug. The cord must be plugged into a mating, grounded 3 prong
outlet, grounded in accordance with all local codes and
ordinances. If a mating outlet is not available, it is the customer’s
responsibility to have a properly grounded 3 prong outlet installed
by a qualified electrical installer.
It is the customer’s responsibility:
To contact a qualified electrical installer.
115-volt (103.5 min. to 126.5 max.)
0 to 12 amps
15-amp time-delay fuse or circuit
breaker
Use on single outlet circuit only.
Electrical Requirements
A. Cabinet louvers
A.
23¼” (59.1 cm) minimum
B. 12⁄” (31.4 cm) minimum
Window Installation
Recommended Grounding Method
Power Supply
Cord Wiring Requirements
Window opening measurements:
23¼” minimum to 36” (59.1 cm to 91.4 cm) maximum opening
width.
12⁄” (31.4 cm) minimum opening height.
A
A
B
4
NOTE: Your air conditioner’s device may differ from the one
shown.
This room air conditioner is equipped with a power supply cord
required by UL. This power supply cord contains state-of-the-art
electronics that sense current leakage. If the cord is crushed, the
electronics detect current leakage and power will be
disconnected in a fraction of a second.
Remove Packaging Materials
Remove and dispose of (or recycle) packaging materials.
Remove tape and glue residue from surfaces before turning on
the air conditioner. Rub a small amount of liquid dish soap over
the adhesive with your fingers. Wipe with warm water and dry.
Do not use sharp instruments, rubbing alcohol, flammable
fluids, or abrasive cleaners to remove tape or glue. These
products can damage the surface of your air conditioner.
Handle the air conditioner gently.
1. Place the top channel on the top of the air conditioner, lining up
the holes in the top channel with the holes in the top of the air
conditioner.
2. Using three ⁄” screws, attach the top channel to the air
conditioner.
NOTES:
The Reset button must be pushed in for proper operation.
The power supply cord must be replaced if it fails to trip when
the test button is pressed or fails to reset.
Do not use the power supply cord as an off/on switch.
A damaged power supply cord must be replaced with a new
power supply cord obtained from the product manufacturer
and must not be repaired.
The power supply cord contains no user serviceable parts.
Opening the tamper-resistant case voids all warranty and
performance claims.
To test your power supply cord:
1. Plug power supply cord into a grounded 3 prong outlet.
2. Press RESET (on some devices, a green light will turn on).
3. Press TEST (listen for click; Reset button will trip, and on
some devices, a green light will turn off).
4. Press and release RESET (listen for click; Reset button will
latch, and on some devices, a green light will turn on). The
power supply cord is ready for operation.
A. Test button
B. Reset button
Power Supply Cord
Install Top Channel
INSTALLATION INSTRUCTIONS
Unpack the Air Conditioner Prepare Air Conditioner for Installation
TEST
RESET
A
B
5
A
B
A. ⁄” screws
B. Top channel
B
A
A
C
D
E
F
B
A
B
NOTE: Attach curtains to the air conditioner before placing the air
conditioner in window.
1. Place the tabbed side of the side curtain in the track on the
right-hand side of the air conditioner cabinet.
3. Slide the side curtain frame into the top channel on the top
of the air conditioner and the track on the bottom of the air
conditioner.
4. Slide the side curtain frame as close to the air conditioner
as necessary to lock the side curtain to the frame.
5. Repeat above steps for the left-hand side curtain and
frame.
Prepare Window for Installation
1. Measure the width of the window opening.
2. Mark the center line on the inside windowsill.
3. Install the Window lock bracket behind the inner windowsill, with
the short side of Window lock bracket as shown.Use the 2 wood
screws 31/32” provided.
The Window lock bracket helps to hold unit securely in place.Be
sure to place Window lock bracket edge flush against back of inner
sill.
A. Tabbed side of side curtain
B. Lock edge side of side curtain
A. Width of window opening
B. Center line
A. Center line
B. ⁄” screws
C. Inner sill
D. Outer sill
E. Short side
F.
Window lock bracket
2. Slide the side curtain down the track until the curtain is
aligned with the top and bottom of the air conditioner
cabinet.
Install Side Curtains
6
NOTE: Your model may differ from the one shown.
A
B
C
A
C
D
B
NOTES:
Handle the air conditioner gently.
Be sure your air conditioner does not fall out of the opening
during installation or removal.
The place where the power cord exits the air conditioner should
be no more than 6 ft (183 cm) from a grounded outlet.
Do not block the louvers in the front panel.
Do not block the louvers on the outside of the air conditioner.
1. Center the air conditioner in the window. Make sure the bottom
guide of the air conditioner drops into the notches of the
basepan angle.Lower the window sash behind the top channel
to hold the cabinet in place
NOTE: Your model may differ from the one shown.
1. Pull the left-hand curtain out until it fits into the window
channel.
2. Use a ⁄” drill bit to drill a starter hole through the top hole in
the side curtain and into the window sash.
3. Insert one of the ⁄” screws through the top hole of the
lefthand curtain and into the window sash.
4. Repeat for the right-hand curtain.
A. Side curtain against window channel
B. Window sash behind top channel
C. Bottom channel in behind windowsill
A. Window frame
B. Top channel
C. Bottom guide
D.
Window lock bracket
Position Air Conditioner
Attach Side Curtains to Window
7
Top View
Bottom View
5. Use a ⁄” drill bit to drill a starter hole through the bottom hole
in the side curtain and into the window frame.
6. Insert one of the ⁄” screws through the bottom hole of the
left-hand curtain and into the window frame.
7. Repeat for the right-hand curtain.
A
B
Complete Installation
1. Insert the foam seal behind the top of the lower window sash
and against the glass of the upper window.
A. Top of lower window sash
B. Foam seal
2. Place the window lock bracket as shown. Use a ⁄” drill bit to
drill a starter hole through the hole in the window lock bracket
and into the upper window.
3. Attach the window lock bracket to the upper window with one
⁄” screw to secure the window in place.
4. Plug into a grounded 3 prong outlet.
5. Press RESET on the power supply cord. See “Electrical
Requirements.”
8
POWER Turn air conditioner on or off.
LOW Low speed fan operate with optional cooling.
HIGH High speed fan operate with optional cooling.
This automatically controls the temperature of indoor air.Turn
the knob so that the arrow points to the cooler marks for more
moderate cooling.
1. Turn the SPEED mode switch to the “HI“ or the “LOW“ setting.
2. Set the thermostat control to the “FAN ONLY” setting .
1. Turn the SPEED mode switch to the “HI“ or the “LOW“ setting.
2. Set the thermostat control to the desired temperature.(The
mid-point is a good starting position .)
If the room temperature is not satisfactory after a reasonable
time,adjust the control to a cooler setting,as appropriate.
1. Turn the SPEED mode switch to the “HI“ setting.
2. Set the thermostat control to the MAX COOL temperature
mark.
1. Turn the SPEED mode switch to the “LOW“ setting.
2. Set the thermostat control as needed.
Operating your air conditioner properly helps you to obtain the
best possible results.
This section explains proper air conditioner operation.
IMPORTANT:
If you turn off the air conditioner, wait at least 3 minutes before
turning it back on. This keeps the air conditioner from blowing a
fuse or tripping a circuit breaker.
Do not try to operate your air conditioner in the Cool mode when
outside temperature is below 65°F (18°C). The inside evaporator
coil will freeze up, and the air conditioner will not operate
properly.
NOTE: In the event of a power failure, your air conditioner will
operate at the previous settings when the power is restored.
AIR CONDITIONER USE
Starting Your Air Conditioner
SPEED
Normal Fan
Normal cooling
Maximum cooling
Quieter operation
9
A
When your air conditioner is operating normally, you may hear
sounds such as:
Droplets of water hitting the condenser, causing a pinging or
clicking sound. The water droplets help cool the condenser.
Air movement from the fan.
Clicks from the thermostat cycle.
Vibrations or noise due to poor wall or window construction.
A high-pitched hum or pulsating noise caused by the modern
high-efficiency compressor cycling on and off.
Changing Air Direction
Use the tab to direct the airflow right or left.
Normal Sounds
A. Tab
10
B
A
Your new air conditioner is designed to give you many years of
dependable service. This section tells you how to clean and care
for your air conditioner properly.
The air filter is removable for easy cleaning. A clean filter helps
remove dust, lint, and other particles from the air and is
important for best cooling and operating efficiency. Check the
filter every 2 weeks to see whether it needs cleaning.
NOTE: Do not operate the air conditioner without the filter in
place.
1. Turn off the air conditioner.
2. Remove the air filter by opening the front panel and removing
the air filter.
Cleaning the Air Filter
AIR CONDITIONER CARE
TROUBLE SHOOTING
A. Air filter
B. Front panel
1. Turn off the air conditioner.
2. Clean the front panel with a soft, damp cloth.
3. Air dry the front panel completely.
4. Turn on the air conditioner.
3. Use a vacuum cleaner to clean air filter. If the air filter is very
dirty, wash it in warm water with a mild detergent. Do not
wash the air filter in the dishwasher or use any chemical
cleaners. Air dry the air filter completely before replacing to
ensure maximum efficiency.
4. Replace the air filter.
5. Close the front panel.
6. Turn on the air conditioner.
Cleaning the Front Panel
A household fuse has blown, or circuit breaker has
tripped. Replace the fuse or reset the circuit breaker. If the
problem continues, call an electrician. See “Electrical
Requirements.”
The Power button has not been pressed or the Mode
control knob is turned to Off. Press POWER or turn the
Mode control knob to an active setting.
The local power has failed. Wait for power to be restored.
Before calling for service, try the suggestions below to see whether you can solve your problem without outside help.
Air Conditioner Will Not Operate
The power supply cord is unplugged. Plug into a grounded
3 prong outlet. See “Electrical Requirements.”
`
The power supply cord has tripped (Reset button has
popped out). Press and release RESET (listen for click; Reset
button will latch and on some devices, a green light will turn on)
to resume operation.
Your air conditioner needs annual maintenance to help ensure
steady, top performance throughout the year. Call your local
authorized dealer to schedule an annual checkup. The expense
of an annual inspection is your responsibility.
Annual Maintenance
11
Too many appliances are being used on the same circuit.
Unplug or relocate appliances that share the same circuit.
Time-delay fuse or circuit breaker of the wrong capacity
is being used. Replace with a time-delay fuse or circuit
breaker of the correct capacity. See “Electrical
Requirements.”
An extension cord is being used. Do not use an extension
cord with this or any other appliance.
You are trying to restart the air conditioner too soon after
turning off the air conditioner. Wait at least 3 minutes after
turning off the air conditioner before trying to restart the air
conditioner.
Air conditioner blows fuses or trips circuit breakers
Disturbances in your electrical current can trip (Reset
button will pop out) the power supply cord. Press and
release RESET (listen for click; Reset button will latch and on
some devices, a green light will turn on) to resume operation.
Electrical overloading, overheating, cord pinching or aging
can trip (Reset button will pop out) the power supply cord.
After correcting the problem, press and release RESET (listen
for click; Reset button will latch and on some devices, a green
light will turn on) to resume operation.
NOTE: A damaged power supply cord must be replaced with a
new power supply cord obtained from the product manufacturer
and must not be repaired.
The air conditioner is not properly sized for your room.
Check the cooling capabilities of your room air conditioner.
Room air conditioners are not designed to cool multiple rooms.
The filter is dirty or obstructed by debris. Clean the filter.
There is excessive heat or moisture (open container
cooking, showers, etc.) in the room. Use a fan to exhaust
heat or moisture from the room. Try not to use heatproducing
appliances during the hottest part of the day.
The louvers are blocked. Install the air conditioner in a
location where the louvers are free from curtains, blinds,
furniture, etc.
The outside temperature is below 65°F (18°C). Do not try to
operate your air conditioner in the cooling mode when the
outside temperature is below 65°F (18°C).
The temperature of the room you are trying to cool is
extremely hot. Allow extra time for the air conditioner to cool
off a very hot room.
Windows or doors to the outside are open. Close all
windows and doors.
The Temperature control is not at a cool enough setting.
Adjust the control to a cooler setting to reduce the temperature.
Set the Fan Speed control to the highest setting.
The current air conditioner replaced an older model. The
use of more efficient components may cause the air conditioner
to run longer than an older model, but the total energy
consumption will be less. Newer air conditioners do not emit
the “blast” of cold air you may be accustomed to from older
air conditioners, but this is not an indication of lesser cooling
capacity or efficiency. Refer to the efficiency rating (EER) and
capacity rating (in Btu/h) marked on the air conditioner.
The air conditioner is in a heavily occupied room, or
heat producing appliances are in use in the room. Use
exhaust vent fans while cooking or bathing and try not to use
heatproducing appliances during the hottest part of the day. A
higher capacity air conditioner may be required, depending on
the size of the room being cooled.
The air conditioner is not properly leveled. The air
conditioner should slope slightly downward toward the outside.
Level the air conditioner to provide a downward slope toward
the outside to ensure proper drainage. See the Installation
Instructions.
NOTE: Do not drill a hole into the bottom of the metal base
and condensate pan.
Air conditioner power supply cord trips (Reset button
pops out)
Air conditioner cycles on and off too much or does not
cool room in cooling mode
Air conditioner seems to run too much
Water drips from cabinet into your house
12
ASSISTANCE OR SERVICE
Before calling for assistance or service, please check
“Troubleshooting.” It may save you the cost of a service call. If
you still need help, follow the instructions below.
When calling, please know the purchase date and the complete
model and serial number of your appliance. This information will
help us to better respond to your request.
If you need replacement parts
If you need to order replacement parts, we recommend that you
use only factory-specified replacement parts. Factory-specified
replacement parts will fit right and work right because they are
made with the same precision used to build every new appliance.
To locate factory-specified replacement parts in your area, call
your nearest designated service center.
Please record your model’s information.
Whenever you call to request service on your appliance, you
need to know your complete model number and serial number.
Visit www.haieramerica.com or call Haier America toll
free: 1-877-337-3639.
Our consultants provide assistance with:
Features and specifications on our appliances.
Installation information.
Use and maintenance procedures.
Repair parts sales.
Referrals to repair parts distributors, and service companies.
Manufacturer-authorized service technicians are trained to
fulfill the product warranty and provide after-warranty service,
anywhere in the United States.
Call Haier America toll free:
1-877-337-3639.
Our consultants provide assistance with:
Features and specifications on our appliances.
Installation information.
Use and maintenance procedures.
Repair parts sales.
Referrals to repair parts distributors, and service companies.
Manufacturer-authorized service technicians are trained to
fulfill the product warranty and provide after-warranty service,
anywhere in the Canada.
For Further Assistance
If you need further assistance, you can write with any questions
or concerns to:
Haier America
1356 Broadway
New York, NY 10018
Please include a daytime phone number in your correspondence.
For Further Assistance
If you need further assistance, you can write with any questions
or concerns to:
Haier America
1356 Broadway
New York, NY 10018
Please include a daytime phone number in your correspondence.
You can find this information on the model and serial number
label. See “Electrical Requirements” for the location of the model
and serial number label.
Please record the model and serial number information below.
Also, record the purchase date of your appliance and the store’s
name, address, and telephone number.
Model Number________________________________________
Serial Number ________________________________________
Purchase Date________________________________________
Store Name __________________________________________
Store Address ________________________________________
Store Phone _________________________________________
Keep this book and the sales slip together for future reference.
In the U.S.A.
In Canada
13
ONE YEAR LIMITED WARRANTY
This warranty covers all defects in workmanship or material for the mechanical and electrical parts (including labor costs) contained in
this product for a period of 12 months from the date of purchase. For commercial or rental application, the warranty is 90 days. You
must keep and be able to provide your original sales receipt as proof of the date of purchase.
ONE YEAR LIMITED WARRANTY ON THE SEALED SYSTEM
The sealed system and compressor (hermetic compressor, condenser and evaporator) contained in this product is for a period of 1 years
from the date of purchase You must keep and be able to provide your original sales receipt as proof of the date of purchase.
WHO IS COVERED
The original retail purchaser of this product.
WHAT WILL BE DONE
Haier America will repair or replace any mechanical, electrical part or the compressor, which proves defective in normal household use
for a period of 12 months.
HOW CAN YOU GET SERVICE
Contact your nearest manufacturer-authorized Service Depot. For the name of the Service Depot nearest you, contact Haier America at
1-877-337-3639.
All service must be performed by a manufacturer-authorized Service Depot.
THIS WARRANTY DOES NOT COVER
1. Damages from improper installation.
2. Damages in shipping.
3. Defects other than manufacturing.
4. Damages from misuse, abuse, accident, alteration, lack of proper care and maintenance or incorrect current or voltage.
5. Damage from other than household use.
6. Damages from service by other than an authorized dealer or service center.
7. Decorative trims or replaceable light bulbs.
8. Labor, service, transportation and shipping charges for the removal of defective parts and installation of replacement parts beyond
the initial 12-month period.
9. Credit or refund for products over 30 days past date of purchase, or for any loss or injury caused by the product or defects to the
product including but not limited to incidental or consequential damages.
10. Food loss for food spoiled as a direct result of mechanical failure of a product or of any delay in providing service, repair or
replacement.
11. Refurbished product purchased as/like new or second-hand.
THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHE R WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies. This warranty does not cover incidental or
consequential damages. Some states do not allow the exclusion of incidental or consequential damages, so this limitation may not
apply to you. Some states do not allow limitations on how long an implied warranty lasts, so this limitation may not apply to you. This
warranty gives you specific legal rights and you may also have other rights which vary from state to state.
This warranty covers units within the continental United States, Canada and Puerto Rico.
LIMITED WARRANTY
A
B
C
D
EFG
A. Canal superior
B. Sello de espuma
C. Soporte de seguridad
para la ventana (3)
D. Tornillos de ⁄” (3)
E. Tornillos de ⁄” (7)
F. Cortinas laterales (2)
G. Marcos para cortinas
laterales (2)
SEGURIDAD DEL ACONDICIONADOR DE AIRE
REQUISITOS DE INSTALACIÓN
Herramientas y piezas
Si no sigue las instrucciones de inmediato, usted puede
morir o sufrir una lesión grave.
Su seguridad y la seguridad de los demás es muy importante.
Hemos incluido muchos mensajes importantes de seguridad en este manual y en su electrodoméstico. Lea y obedezca siempre
todos los mensajes de seguridad.
Este es el símbolo de advertencia de seguridad.
PELIGRO
ADVERTENCIA
Todos los mensajes de seguridad irán a continuación del símbolo de advertencia de seguridad y de la palabra
“PELIGRO” o “ADVERTENCIA”. Estas palabras significan:
Este símbolo le llama la atención sobre peligros potenciales que pueden ocasionar la muerte o una
lesión a usted y a los demás.
Todos los mensajes de seguridad le dirán el peligro potencial, le dirán cómo reducir las posibilidades de sufrir una lesión y lo que
puede suceder si no se siguen las instrucciones.
Si no sigue las instrucciones, usted puede morir o sufrir
una lesión grave.
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
ADVERTENCIA:
Para reducir el riesgo de incendio, choque eléctrico o lesiones personales al usar su acondicionador de aire,
siga estas precauciones básicas:
CONSERVE ESTAS INSTRUCCIONES
Desconecte el acondicionador de aire antes de
darle servicio.
Use dos o más personas para mover e instalar el
acondicionador de aire.
Conecte a un contacto de pared de conexión a tierra de
3 terminales.
No quite el terminal de conexión a tierra.
No use un adaptador.
No use un cable eléctrico de extensión.
Reúna todas las herramientas y piezas necesarias antes de
comenzar la instalación. Lea y siga las instrucciones provistas
con cualquiera de las herramientas enlistadas aquí.
Herramientas necesarias
Piezas suministradas
Verifique que todas las piezas estén incluidas en el paquete de
piezas.
■ Destornillador Phillips
■ Destornillador de cabeza
plana
■ Tijeras
■ Nivel
■ Llave de cubo y puntas
■ Cinta de medir
■ Taladro inalámbrico y broca
de 1/8”
■ Lápiz
■ Pinzas
■ Llave ajustable
14
A
ADVERTENCIA
Conecte a un contacto de pared de conexión a tierra de
3 terminales.
No quite la terminal de conexión a tierra.
No use un adaptador.
No use un cable eléctrico de extensión.
No seguir estas instrucciones puede ocasionar la
muerte, incendio o choque eléctrico.
Peligro de Choque Eléctrico
Requisitos de ubicación
IMPORTANTE:Observe todos los códigos y reglamentos
aplicables.
Verifique el lugar donde se instalará el acondicionador de aire.
Asegúrese de tener todo lo necesario para una instalación
correcta.
El lugar debe tener:
Contacto con conexión a tierra a no más de 6 pies (183 cm)
de donde el cable eléctrico sale del acondicionador de aire.
NOTA: No use un cable eléctrico de extensión.
Libertad de movimiento del aire en la habitación que desea
enfriar.
Una abertura con la amplitud suficiente para el
acondicionador de aire. Se proveen piezas de instalación
para las ventanas de guillotina.
Un soporte adecuado en la pared para el peso del
acondicionador de aire. El acondicionador de aire pesa entre
36 lbs to 42 lbs (16.3 kg to 19.1 kg).
NOTA: No deben obstruirse las rejillas de la carcasa. El aire
debe circular libremente a través de las rejillas de la carcasa.
Las clasificaciones eléctricas para su acondicionador de aire
están enumeradas en la etiqueta de número del modelo y de
serie. La etiqueta con número de modelo y de serie está ubicada
a los lados, en la parte posterior de la carcasa del acondicionador
de aire o detrás de la rejilla frontal.
Los requisitos eléctricos específicos se indican en la tabla a
continuación. Siga los requisitos para el tipo de enchufe en el
cable de suministro de energía.
Este acondicionador de aire debe estar conectado a tierra. Este
acondicionador de aire está equipado con un cable de suministro
de energía provisto de un enchufe de tres terminales de
conexión a tierra. El cable deberá ser enchufado en un contacto
apropiado de 3 terminales, conectado a tierra de acuerdo con
todos los códigos y ordenanzas locales. Si no se dispone de un
tomacorriente apropiado, es responsabilidad del cliente hacer
instalar un contacto con tres terminales debidamente puesto a
tierra por un instalador eléctrico competente.
Es responsabilidad del cliente:
Ponerse en contacto con un instalador eléctrico calificado.
115 voltios (103,5 mínimo a 126,5
máximo)
0-12 amperios
Fusible de retardo de 15 amperios o
cortacircuitos
Úselo solamente en un circuito con
tomacorriente único.
Requisitos eléctricos
A. Rejillas de la carcasa
A. 23¼” (59.1 cm) como mínimo
B. 12⁄” (31.4 cm) como mínimo
Instalación en la ventana
Método de conexión a tierra recomendado
El cable eléctrico Requisitos de cableado
Medidas de abertura de la ventana:
Ancho de la abertura de 23¼” como mínimo a 36” (59.1 cm a
91,4 cm) como máximo.
Altura mínima de la abertura de 12⁄” (31.4 cm).
A
B
15
NOTA:El dispositivo de su acondicionador de aire puede ser
diferente del que se ilustra.
Este acondicionador de aire para habitación está equipado con
un cable de suministro de energía según lo exige UL. Este cable
de suministro de energía incluye circuitos electrónicos de última
generación que detectan la corriente de fuga. Si se aplasta el
cable, el elemento electrónico detecta la corriente de fuga y la
energía se desconecta en una fracción de segundo.
Quite los materiales de empaque
Quite y deshágase de todos los materiales de embalaje o
recíclelos. Quite las cintas y los residuos de goma del
acondicionador de aire antes de encenderlo.
Frote un poco de detergente líquido para vajillas sobre el
adhesivo con los dedos. Limpie con agua tibia y seque.
No use instrumentos filosos, alcohol para fricciones, líquidos
inflamables o productos de limpieza abrasivos para eliminar
los restos de cinta o goma. Estos productos pueden dañar la
superficie de su acondicionador de aire.
Trate el acondicionador de aire con cuidado.
A. Botón de prueba
B. Botón de reposición
Cable de suministro de energía
INSTRUCCIONES DE INSTALACIÓN
Desempaque el acondicionador de aire
ADVERTENCIA
Conecte a un contacto de pared de conexión a tierra de
3 terminales.
No quite la terminal de conexión a tierra.
No use un adaptador.
No use un cable eléctrico de extensión.
No seguir estas instrucciones puede ocasionar la
muerte, incendio o choque eléctrico.
Peligro de Choque Eléctrico
ADVERTENCIA
Use dos o más personas para mover e instalar el
acondicionador de aire.
No seguir esta instrucción puede ocasionar una lesión
en la espalda u otro tipo de lesiones.
Peligro de Peso Excesivo
TEST
RESET
A
B
Para poner a prueba el cable de suministro de energía:
1. Enchufe el cable de suministro de energía en un tomacorriente
de 3 terminales con conexión a tierra.
2. Presione RESET (Reposición) (en algunos aparatos se
encenderá una luz verde).
3. Presione TEST (Prueba) (escuche el chasquido, el botón de
reposición se atrapará y en algunos aparatos se apagará una
luz verde).
4. Presione y suelte RESET (escuche el chasquido, el botón de
reposición queda asegurado y en algunos aparatos se
encenderá una luz verde). El cable de suministro de energía
está listo para su funcionamiento.
NOTAS:
■ El botón de reposición debe presionarse para el funcionamiento
adecuado.
■ El cable de suministro de energía debe ser reemplazado si no
se dispara cuando se presione el botón de prueba o cuando
falle la reposición.
■ No use el cable de suministro de energía como un interruptor
de encendido y apagado.
■ Un cable de suministro de energía dañado debe ser
reemplazado por un nuevo cable de suministro de energía
obtenido del fabricante del producto y no debe ser reparado.
■ El cable de suministro de energía no contiene piezas que
pueda arreglar el usuario. Todos los reclamos de desempeño
y la garantía quedarán anulados si se abre el estuche
resistente a alteraciones.
16
B
A
A
B
NOTA:Su modelo podría variar del modelo que se muestra.
NOTA:Sujete las cortinas al acondicionador de aire antes de
colocar éste en la ventana.
1. Coloque el lado con lengüetas de la cortina lateral en el riel
que está sobre el lado derecho de la carcasa del
acondicionador de aire.
3. Deslice el marco de la cortina lateral dentro del canal
superior, en la parte superior del acondicionador de aire, y la
vía en la parte inferior del mismo.
4. Deslice el marco de la cortina lateral lo más cerca del
acondicionador de aire, según sea necesario, para asegurar
la cortina lateral al marco.
5. Repita los pasos de arriba para la cortina y el marco del lado
izquierdo.
Preparación de la ventana para la instalación
1. Mida el ancho de la abertura de la ventana.
2. Marque la línea central en el lado interior de la repisa de la
ventana.
A. Tornillos de ⁄
B. Canal superior
A. Lado con lengüetas de la cortina lateral
B. Lado del borde de cierre de la cortina lateral
A. Ancho de la abertura de la ventana
B. Línea central
2. Deslice la cortina lateral hacia abajo sobre el riel hasta que
quede alineada con la parte superior e inferior de la carcasa
del acondicionador de aire.
Instalación de las cortinas laterales
1. Coloque el canal superior sobre la parte superior del
acondicionador de aire, alineando los orificios en el canal
superior con los orificios en la parte superior del
acondicionador de aire.
2. Sujete el panel superior al acondicionador de aire usando tres
tornillos de ⁄”.
Instale el canal superior
Prepare el acondicionador de aire para la instalación
A
B
17
A
C
D
E
F
B
3. Instale los pies destrás del umbral interno de la forma en que muestra la figura.Utilice los dos tornillos para madera 31/32” provistos.
Estos soportes de ángulos ayudana mantener firme y segura la unidad en su lugar.
A. Línea central
B. Tornillo MAD.⁄
C. Umbral
D. Umbral externo
E. Lado corto
F.
Angulos
ADVERTENCIA
Use dos o más personas para mover e instalar el
acondicionador de aire.
No seguir esta instrucción puede ocasionar una lesión
en la espalda u otro tipo de lesiones.
Peligro de Peso Excesivo
NOTAS:
Trate el acondicionador de aire con cuidado.
Cerciórese de que el acondicionador de aire no se caiga de la
abertura durante la instalación o al quitarlo.
El lugar de donde sale el cable de suministro eléctrico del
acondicionador de aire no deberá estar a más de 6 pies (183
cm) de un contacto con conexión a tierra.
No bloquee las rejillas del panel frontal.
No bloquee las rejillas que están en el exterior del
acondicionador de aire.
1. Centre el acondicionador de aire en la ventana. Baje el
bastidor de la ventana que está detrás del canal superior
para sostener la carcasa en su lugar.
NOTE: Your model may differ from the one shown.
A. Cortina lateral contra el canal de la ventana
B. Bastidor de la ventana detrás del canal superior
C. Canal inferior detrás del marco de la ventana
Coloque el acondicionador de aire en su lugar
A
B
C
A
C
D
B
A. VENTANA
B. GUíA SUP
C. GUíA
D.
ÁNGULO
1. Jale la cortina izquierda hacia fuera hasta que encaje en el
canal de la ventana.
2. Use una broca de ⁄” para taladrar un primer orificio en el
bastidor de la ventana, a través del orificio superior que está
en la cortina lateral.
3. Inserte uno de los tornillos de ⁄” en el bastidor de la
ventana, a través del orificio superior de la cortina del lado
izquierdo.
4. Repita el procedimiento para la cortina del lado derecho.
5. Use una broca de ⁄” para taladrar un primer orificio en el
marco de la ventana, a través del orificio inferior que está en
la cortina lateral.
6. Inserte uno de los tornillos de ⁄” en el marco de la ventana,a
través del orificio inferior de la cortina del lado izquierdo.
7. Repita el procedimiento para la cortina del lado derecho.
Encaje las cortinas laterales en la ventana
18
A
B
Vista superior
Vista inferior
19
ADVERTENCIA
Conecte a un contacto de pared de conexión a tierra de
3 terminales.
No quite la terminal de conexión a tierra.
No use un adaptador.
No use un cable eléctrico de extensión.
No seguir estas instrucciones puede ocasionar la
muerte, incendio o choque eléctrico.
Peligro de Choque Eléctrico
Complete la instalación
1. Inserte el sello de espuma detrás de la parte superior del
bastidor de la ventana inferior y contra el vidrio de la ventana
superior.
A. Parte superior del bastidor de la ventana inferior
B. Sello de espuma
2. Coloque el soporte de seguridad de la ventana como se
muestra. Use una broca de ⁄” para taladrar un primer orificio
en la ventana superior, a través del orificio que está en la el
soporte de seguridad de la ventana.
3. Sujete el soporte de seguridad de la ventana a la ventana
superior con un tornillo de ⁄” para asegurar la ventana en
su lugar.
4. Conecte a un contacto de pared de conexión a tierra de 3
terminales.
5. Presione RESET (Reposición) en el cable de suministro de
energía. Vea “Requisitos eléctricos”.
POWER Apaga el acondicionador de aire.
BAJA Disminuye la velocidad de ventilación mientras esté
entriando o no.
ALTA Acelera la operación de ventilación.La unidad controla
automáticamente del ambiente.Gire la perilla apuntando a los
indicadores de fr
ío para una operación más moderada.
1. Seleccione el modo de ventilación ALTO o BAJO.
2. Indique con el control del termostato “FAN ONLY” (solo
ventilación) .
1. Seleccione el modo de ventilación ALTO o BAJO.
2. Indique con el control del termostato la temperatura
deseada(es bueno comenzar en el punto dedio).
Si la temperatura del ambiento no es satisfactoria luego de un
largo tiempo ajuste los controles a una selección más apropiada.
1. Seleccione el modo de ventilación a ALTO.
2. Indique con el control del termostato “MAX COOL“(fr
ío
maximo).
1. Seleccione el modo de ventilación BAJO.
2. Seleccione el control del termostato como lo desee.
Cómo poner en marcha su acondicionador de aire
VELOCIDAD
Ventilaci
ón NORMAL
Frio Normal
Frio MÁXIMO
Operaci
ón TRANQUILA
A
Cómo cambiar la dirección del aire
Gire la rueda para dirigir el aire hacia la derecha o hacia la
izquierda.
Operar debidamente su acondicionador de aire le permite
obtener los mejores resultados posibles.
Esta sección le explica cómo operar su acondicionador de aire
debidamente.
IMPORTANTE:
Si usted apaga el acondicionador de aire, espere por lo
menos 3 minutos antes de volver a ponerlo en marcha. Esto
evita que se queme un fusible del hogar o se dispare un
cortacircuitos a causa del acondicionador de aire.
No trate de operar su acondicionador de aire en el modo de
Cool (Enfriamiento) cuando la temperatura exterior sea menor
de 65 °F (18 °C). El serpentín interior del evaporador se
congelará y el acondicionador de aire no funcionará
debidamente.
NOTA:En caso de corte de electricidad, el acondicionador de
aire funcionará con los ajustes previos cuando se restablezca la
energía eléctrica.
CÓMO USAR EL ACONDICIONADOR DE AIRE
Cuando el acondicionador de aire está funcionando
normalmente, usted podrá escuchar sonidos como:
Gotas de agua que caen sobre el condensador, produciendo
tintineos o chasquidos. Las gotas de agua ayudan a enfriar
el condensador.
El movimiento del aire que sale del ventilador.
Chasquidos del ciclo del termostato.
Vibraciones o ruidos debidos a deficiencias en la
construcción de la pared o ventana.
Un zumbido agudo o un ruido pulsante producido por la
alternación de los ciclos de encendido y apagado del oderno
compresor de alta eficiencia.
Sonidos normales
A. Rueda
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Haier HWF05XCK-E Le manuel du propriétaire

Taper
Le manuel du propriétaire