Modern Forms PD-34620 Tango Mode d'emploi

Catégorie
Mur
Taper
Mode d'emploi
1
INSTALLATION INSTRUCTIONS
Tango – LED Pendant
PD-34620
HARDWARE
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. May. 2020
CAUTION: To prevent electrical shock, ensure electricity has been turned off at the circuit breaker before beginning.
Read all instructions before installing.
System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
When handling the fixture, do not apply pressure to the LEDs. Hold the fixture by the base only.
Retain installation instructions for future maintenance reference.
WARNING: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern
Forms could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any
parts are damaged or missing.
MAINTENANCE NOTE: Coastal conditions may cause mineral and residue build-up on the fixture. We recommend that customers in coastal
areas clean all external surfaces of the fixture once every two weeks with a wet cloth.
MISE EN GARDE: Pour éviter tout choc électrique, assurez-vous que le disjoncteur soit mis hors tension avant de commencer.
Lisez toutes les instructions avant l’installation.
Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également aux
règlements locaux.
Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
ATTENTION: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement
avec les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus
pour ce produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la
garantie. Veuillez contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
NOTE D’ENTRETIEN: Les conditions côtières peut causer une accumulation de minéraux et de résidue sur le luminaire. Nous recommendons
aux clients qui resident dans les zones côtières de nettoyer toutes les surfaces externes du luminaire une fois toutes les deux semaines avec
un chiffon humide.
Wire Connector
Qty: 3pcs+1Extra
Mounting Screw
Qty:1 Extra
A B C D
Plastic Anchor
Qty: 3pcs+1 Extra
Qty: 3pcs+1 Extra
Wood Screw
2
INSTALLATION INSTRUCTIONS
Tango – LED Pendant
PD-34620
FIG. 1
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. May. 2020
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
PREPARATION
1. Shut off the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screw (B) and back plate from the xture.
4. Drill holes in the wall aligned with the key holes located in the mounting back plate, insert the plastic anchor (D).
5. Secure the mounting back plate to the junction box using standard junction box screws that comes with the junction box, fasten it to the
wall using wood screw (C) .
Note: (i) using any other non-original-manufacturer provided junction box screw may result in safty issue;
(ii) The side of the mounting plate marked “GND” must face out.
6. Adjust the xture wire length by pushing the cable gripper on the canopy and pulling the wire as desired.
Retract these wires close to a desirable length to within the canopy before securing the xture in place.
Note: retracting or extending excessive cable length through the cable gripper is not recommended.
Warning: Shortening these cables without professional helps or electronic background is not advisable. Any modications to the xture
will result in voiding the warranty of the product.
7. Please follow these if shortening the wire is needed. Take note or take picture of how the wires are being connected and label each wire
clearly. Using the gure X as given below as reference. (Fig. 2)
CONNECTING THE WIRES (Fig. 3)
8. Connect the driver’s input wires to junction box wires as shown in Fig. 3, making sure that all wire connectors (A) are secured. If your outlet
box has a green or bare copper ground wire, connect the xtures ground wire to it. Otherwise, connect the xture’s ground wire directly
to the backplate using the screw provided. After wires are connected, tuck them carefully inside the junction box.
9. Place the xture over the mounting back plate and secure it with mounting
screws (B).
10. After installed, adjust the lamp body frame like the Fig.1.
COMPLETING THE INSTALLATION
11. Secure the xture to the mounting back plate using the mounting screw (B) .
DIMMING WIRING INFORMATION (Fig. 4)
12. This xture features electronic low voltage (ELV or TRAIC) or 0-10V dimming
capabilities. See notes below for specic dimming wires information.
13. To utilize ELV or TRAIC dimming: use wires black (hot), white (neutral) and bare
copper ground wire (ground).
14 To utilize 0-10V dimming: use wire purple (dim+), gray (dim-), black (hot),
white (neutral) and bare copper ground wire (ground).
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
FIG. 3 Wiring
FIG. 4
FIG. 2
Purple - Dim+
Gray - Dim-
Black - Hot
White - Neutral
Black - Output -
Red - Output +
Mounting Screw
Mounting Backplate
Ground WireJunction Box
Wire Connector
Junction Box Screw
Wood Screw
Push up
Cable-gripper
Instruction:Adjust the xture wire
length by pushing the cable
gripper on the canopy and
pulling the wire as desired.
Driver: 2 7/8" L x
1 3/8"W x 1 1/8"H
A
B
C
D
Platsic Anchor
Back Plate Dimensions
8 7/8"
8 7/8"
3 1/2"
1 5/8"
Output
Input
Driver2
White -
Neutral
Black -
Hot
Fixture
Input
Driver1
Outer bare cord
Inner cord
Output
Inner cord
Outer bare cord
No electricity