Honeywell DT8035 Dual Tec Quick Installation Manual

Catégorie
Détecteurs de mouvement
Taper
Quick Installation Manual
DT8035 DUAL TEC
®
Motion Sensor - Quick Installation Guide
Détecteur de mouvement DT8035 DUAL TEC
MD
– Guide d'installation rapide
Sensor de Movimiento DUAL TEC
®
DT8035 – Guía Rápida de Instalación
Sensor de Movimento DUAL TEC
®
DT8035 – Guia rápido de instalação
1
6' 9" - 8' 9"
(2.1 - 2.7 m)
7' 6"
(2.3 m)
≤ 100 lbs / 45 kg
Optimal
Optimal
Optimo
Ótimo
2
3
2
1
1
3
A
B
#6 x 1"
(3.5 mm x 25 mm)
X
#6 x 1"
(3.5 mm x 25 mm)
A
A
B
BB
X
4
MW
SENSITIVITY
MAX
MIN
*
LOOKDOWN
ON
OFF
MIN MAX
MW
LED
PI
*
ON
OFF
DT8035
*Enabled
*Activé
*Habilitado
*Habilitado
Disabled
Désactivé
Deshabilitado
Deshabilitado
ON
OFF
Pet Immunity
Insensibilité aux animaux
Tolerancia a mascotas
Pet-Imunidade
*
Microwave Range Adjustment
Réglage de la portée des micro-ondes
Ajuste del rango de detección Microondas
Ajuste de Alcance Microondas
* Factory default / Valeurs par défaut du fabricant /
Defecto de fábrica / Padrão de fábrica
PI LED
ON OFF
(Sensibilité micro-ondes)
(Sensibilidad de Microonda)
(Sensibilidade da Microonda)
- 2 -
T C V-V+
T NC
5
Ground +12V
Zone
#
Zone
COM
Zone
#
Zone
COM
Tamper
30 mA
25 VDC
Power
17 mA
9-15 VDC
(UL: 9.5-15 VDC)
Alarm
30 mA
25 VDC
6 4 2 15 3
22-20 AWG
(0.31-0.52mm2)
2
2
1
T C V-V+
T NC
6 4 2 15 3
Panel / Panneau / Panel / Controle
Sensor / Détecteur / Sensor / Sensor
30 sec
30
0
45
20
10
6
MW
SENSITIVITY
MAX
MIN
*
ON
PI LED
1/2 sec.
hold 4x
< 4’ (1.2m)
Walk Test Reset
1. Apply power to the sensor. Initialization is complete when the LED stops
flashing slowly (about 30 seconds).
2. Turn the microwave sensitivity counterclockwise to reduce the microwave
range (minimum = 16.4’ / 5m) and close the sensor.
3. Walk through the detection area and observe the LED.
4. Adjust the microwave range as necessary to meet installation requirements.
Walk test mode is active for 10 minutes, then automatically exits test mode, disables the LED and enters normal
operation mode. For an additional 10 minute walk test, enable walk test mode again with the flashlight feature (see Walk
Test Reset above).
Note: During power up and walk test modes the LED is active regardless of the LED Enable/Disable DIP switch setting.
7
PLAN VIEW
ALL ZONES
A B C D
7.5ft
(2.3m)
0ft
(0m)
7ft
(2m) 13ft
(4m) 20ft
(6m) 27ft
(8m) 33ft
(10m) 40ft
(12m)
13ft
(4m)
0ft
(0m) 7ft
(2m) 13ft
(4m) 20ft
(6m) 27ft
(8m) 33ft
(10m) 40ft
(12m)
7ft
(2m)
0ft
(0m)
7ft
(2m)
13ft
(4m)
20ft
(6m)
20ft
(6m)
27ft
(8m)
33ft
(10m)
27ft
(8m)
33ft
(10m)
Top View
Vue de dessus
Vista Desde Arriba
Vista Superior
Side View
Vue de coté
Vista Lateral
Vista Lateral
LED Power Up
Walk Test Normal Fault
Red Slow
Blink
ON
Alarm
ON
Alarm
Fast
Blink
Yellow OFF ON
Microwave
ON
Microwave OFF
Green OFF ON
PIR
ON
PIR OFF
Zones / Zones / Zonas / Zonas
A
2
Look-down / Basses / Vista Zona 0 /
Vigilância inferior
B
18
Lower / Courtes / Cercana/ Mais baixas
C
46
Intermediate / Intermédiaires / Intermedia /
Intermédias
D
36
Long / Longues / Largo Alcance / Longo
alcance
- 3 -
SPECIFICATIONS:
Operating Temperature: 14° to 131° F / -10° to 55° C
Relative Humidity: 5 to 93% (UL tested at 93%); non-condensing
TROUBLESHOOTING:
TROUBLE*
NORMAL
Self
Test Failure
1
Alarm Relay
Closed Open
Red LED
Off Flashing
*TROUBLE CONDITIONS:
1
Self-Test Failure conditions:
• Microwave supervision failure: The sensor is operating in PIR mode only.
• PIR self-test failure: The sensor is disabled.
• Temperature compensation failure: The temperature compensation is disabled.
Depending on the Trouble condition, take the following corrective actions:
• Verify the power supply is sufficient (at least 9V at the sensor).
• Cycle power to the sensor.
• Walk test the sensor.
If the Trouble condition does not clear, replace the sensor.
APPROVAL LISTINGS:
FCC part 15, Class B verified
IC ICES-003, Class B verified
UL 639
ULC S306-03
SIA-PIR-01 Passive Infrared detector standard features for false alarm immunity.
Product must be tested at least once each year / Le fonctionnement du produit doit être vérifié au moins une fois par année /
El producto debe ser probado al menos una vez al año / O produto deve ser testado pelo menos uma vez por ano
All wiring must be in accordance with: the National Electrical Code (ANSI/NFPA70); the Canadian Electrical Code, Part I (where applicable); UL681,
Standard for Installation and Classification of Burglar and Holdup Alarm Systems; ULC-S302, Standard for Installation and Classification of Burglar
Alarm Systems for Financial and Commercial Premises, Safes and Vaults; ULC-S310, Standard for Installation and Classification of Residential Burglar
Alarm Systems; local codes and the authorities having jurisdiction.
The products are intended to be powered by a power-limited output of a UL/CUL Listed Burglar Alarm control unit, or via a Listed UL603/ULC-S318
power-limited power supply that provides 4 hours of standby power.
The sensor must be mounted indoors, within the protected premises, and on a wooden stud, solid wood or with a robust wall anchor.
UL Notes: All interconnecting devices must be UL listed. The pet immunity feature has not been evaluated by UL.
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual.
Unauthorized changes or modifications could void the user's authority to operate the equipment.
CLASS B DIGITAL DEVICE STATEMENT
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your
information:
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the
manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for
a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection
against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
Reorient the receiving antenna until interference is reduced or eliminated.
Move the radio or television receiver away from the receiver/control.
Move the antenna leads away from any wire runs to the receiver/control.
Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits.
• Consult the dealer or an experienced radio/TV technician for help.
INDUSTRY CANADA CLASS B STATEMENT
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause
undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux
conditions suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris
les interférences causant une réception indésirable.
For the latest documentation and online support information, please go to:
Pour de l’assistance en ligne, visitez :
Para recibir soporte en línea, visite:
Para qualquer informação adicional, contacte:
http://www.security.honeywell.com/hsc/resources/MyWebTech/
For the latest U.S. warranty information, please go to: www.honeywell.com/security/hsc/resources/wa or
Please contact your local authorized Honeywell representative for product warranty information.
Pour obtenir de l'information sur la garantie de ce produit, veuillez communiquer avec le représentant
autorisé de Honeywell de votre région.
Por favor contacte con su distribuidor Honeywell Security para información sobre la garantía del producto.
Contacte o representante autorizado Honeywell local para obter informações relativas a garantia.
2013 Honeywell International Inc. Honeywell and DUAL TEC are registered trademarks of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved. Made in China.
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
www.honeywell.com/security
P/N 800-15115-05 03/14 Rev B
To protect the environment, a detailed installation guide is available on