1
AC 102 and AC+USB 311 No AC Power Modules
for the Cable Cubby Enclosures • Installation Guide
The AC102 and AC+USB 311 No AC Power Modules provide slots for installing one or two compatible AC outlets (purchased
separately) for powering and charging laptops and other portable devices. The No AC Power Modules are compatible with the
following outlets:
Legrand Israel 572124 — White Legrand India 573471 — White
Legrand Israel 572624 — Magnesium Legrand India 573671 — Magnesium
See the CAUTION and ATTENTION notifications before installing the outlets and mounting the power module. Follow the steps
below to properly install and secure the module.
Installing the AC Outlets in the Power Modules
CAUTION:
ATTENTION :
All electrical installation should be performed by qualified personnel in accordance with local and national building, fire
and safety, and electrical codes.
Toute installation électrique devrait être effectuée par un personnel qualifié, conformément aux codes du bâtiment, aux
codes incendie et sécurité, et aux codes électriques locaux et nationaux.
To ensure proper electrical grounding, use the provided #6-32 grounding screws and star washers.
Afin d’assurer une mise à la terre correcte, utilisez les fixations de mise à la terre #6-32 et les rondelles en étoile fournies.
ATTENTION: Follow all national and local building and electrical codes that apply to the installation site. Extron is not liable nor
responsible for damage or injury as a result of installing this product. It is the responsibility of the qualified installer to ensure
applicable safety, compliance, and technical steps have been performed in accordance to regulatory, building and electrical
standards.
The AC 102 No AC power module has two slots at the top, through which you can
access two sets of cables in order to wire them to the outlets. The AC+USB 311 has one slot
and one set of cables for wiring. Each set consists of the following three colored cables:
Brown — Live Blue — Neutral Green — Ground
To wire the outlets to the module:
1. Each set of cables (one brown, one blue, and one green) is zip-tied together and placed
inside the module (see
1
in the illustration at right). Pull one zip-tied set of cables out
through each slot, so that the loose ends of the cables are accessible (
2
).
2. Remove the partially-severed insulation from the ends of the cables to expose the bare
wires (
3
).
3. Place the module on a flat surface with the slots facing up and the word Top (between two
arrows pointing up) facing toward you, as shown at right.
4. Attach the wires to each outlet as follows:
a. Loosen the three screws on the back of the outlet (see
1
in the illustration below, right).
b. Insert each wire into the appropriate captive screw
connector (use either of the two holes):
Live (brown) cableL connector (
2
)
Ground (green) cable — Ground connector (
3
),
labeled with __.
Neutral (blue) cable N connector (
4
)
c. After inserting each wire, tighten the screw above it to
hold it in place (
1
). Pull gently on each wire to ensure
it is securely attached.
240V~ 50-60Hz 10A MAX TOTAL
TOP
11
3
3
2
2
L
N
Blue = Neutral
Green = Gr
ound
Brown = Live
1
1
1
3
3
3
2
2
2
4
4
4
Figure 2. Connecting Wires to AC Outlet
IMPORTANT:
Go to www.extron.com for the
complete user guide and installation
instructions before connecting the
product to the power source.
Figure 1. AC 102 Module with Wires
68-3360-01 Rev. D
06 21
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
© 2019-2021 Extron — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
2
Installing the Assembled Power Module in the Cable Cubby Enclosure
Follow the steps to install and secure the assembled AC power modules for each compatible Cable Cubby enclosure.
NOTE: To view the power specifications pertaining to this product, see www.extron.com.
5. Position the outlets to the AC 102 or AC+USB 311
module as shown in figure 3 at right.
Place an outlet into the left slot of the AC 102
module or the right slot of the AC+USB 311
module (see figure 3,
1
).
Place the other outlet of the AC 102 module
into the right slot 90 degrees counterclockwise
(
2
).
6. Press each outlet into the slot until the flanges (
3
)
on opposite edges of the outlet snap into place
and the outlet is held securely.
240V~ 50-60Hz 10A MAX TOTAL
Figure 3. Position and Snap the AC Outlets into the Power Modules
Figure 4. Top View of the Power Modules with Israel AC Outlets
Figure 5. Installing the AC 102 Power Module in the Cable Cubby 1202 Enclosure
Position the AC outlets and install as shown.
USB CHARGER
240V~ 50-60Hz 10A MAX
N
E
L
240V~ 50-60Hz 10A MAX TOTAL
TOP
240V~ 50-60Hz 10A MAX
USB CHARGER
TOP
3
1
2
2
2
2
2
33
3
3
3
3
Insert the module
into the Cable Cubby.
1
Secure the module
using four of the provided
pan-head mounting scr
ews
and star washers.
2
AC 102 with Israel OutletsA
C
102
TOP
  • Page 1 1
  • Page 2 2

Extron AC+USB 200 Series Power Module Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues